The ul�mate solu�on for a refreshingly cool space COOLING ONLY [60Hz], 220V Perfecting the Air Non-Inverter WORLD’s AIRCONDITIONING COMPANY YEARS WARRANTY 5 C O M P R E S S O R Japan Quality YEAR WARRANTY 1 P A R T S & L A B O R

Perfecting the Air - Daikin Philippines

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Perfecting the Air - Daikin Philippines

The ul�mate solu�on for a refreshingly cool space

COOLING ONLY [60Hz], 220V

Per fec t ing t he Ai r

Non-Inver ter

WORLD’s

AIRCONDITIONINGCOMPANY

YEARSWARRANTY5

COMPRESSOR

JapanQuality YEAR

WARRANTY1 PARTS & LABOR

Page 2: Perfecting the Air - Daikin Philippines

Outdoor unit

Indoor unit

RR100AGXVLRR125/140AGXTL9

RR71AGXVLRR50/60AGXVL

Durability• The unit is covered with corrosion-proof galvanized steel to enhance its durability.• Heat exchange �ns are provided with anti-corrosion treatment.

Fitted with wide inlet fan

Wide inlet fan

Pre-charged for up to 7.5 metresModel Max. piping length, m Max. piping elevation, m

RR50A

RR60A

RR71A

RR100ARR125ARR140A

30

50

50

15

25

30

Fully shaped aerodynamic propellers are designed to push air with a large wing surface, providing both high blow volume and quiet operation with turbulence.

FHRN100AXVL/140AXVL9Ceiling Suspended

4HP / 6HP

FVRN71/100AXVL/125/140AXVL9Floor Standing

3HP / 4HP / 5HP / 6HP

FCRN50/60/71/100AXVL/125AXVL92HP / 2.5HP / 3HP / 4HP / 5HP

Ceiling Cassette

2HP / 2.5HP / 3HP / 4HP / 5HP / 6HP

Duct ConnectionFDMRN50/60/71/100AXVL/125/140AXVL9

Standard Static Pressure Type

Non-Inver ter

Page 3: Perfecting the Air - Daikin Philippines

Work & ServicingDrain pump mechanismPre-charged for up to 7.5mSelf-Diagnosis

OptionalGroup control by NetworkInterface Module (NIM)

External command control using BAG

Wired Remote Controller

ComfortAuto-swingSwing PatternSwitchable fan speedProgramme “Dry”

Timer SelectorTwo selectable temperature sensor*

* Applicable when wired controller is used

Weekly scheduled timer*

Ceiling Suspended

FHRN140AXVL9

RR140AGXTL9

56,000

16.41

6,240

18.8

3/220/60

COP 2.63

Air Flow Rate (H/M/L) 1550/1380/1000

Sound Pressure Level (H/M/L) 56/54/51

Dimension (H x W x D)

Machine Weight 70

Sound Pressure Level 66

Dimension (H x W x D)

Machine Weight 101

Pipe Connection-Liquid

Pipe Connection-Gas

FHRN100AXVL

RR100AGXVL

35,000

10.26

3,800

17.3

1/220/60

2.70

1107/999/751

49/46/43

52

61

71

15.9 19.05

Indoor Unit

Outdoor Unit

Btu/hr

kW

Watts

A

Ph/V/Hz

W/W

cfm

dBA

mm

Kg

dBA

mm

Kg

mm

mm

Model Name

Power Supply

Rated Cooling Capacity (Min. ~ Max.)

Power Consumption

Total Running Current

OUTDOOR

INDOOR

9.5

235 x 1,903 x 680 285 x 1,903 x 680

852 x 1,030 x 400

mMinimum Piping Length 3 5

FHRN140AXVL9

RR140AGXTL9

50

50

FHRN100AXVL

RR100AGXVL

7.5

30

30

Indoor Unit

Outdoor Unit

m

g/m

Model Name

Chargeless Refrigerant

mMaximum Piping Elevation

mMaximum Piping Length

Additional RefrigerantCharge

CleanlinessWashablesaranet filter

Control FeaturesAuto random restart

Work & ServicingDrain pump mechanismPre-charged for up to 7.5mSelf-Diagnosis

OthersAnti-corrosion treatedheat exchangers

OptionalFresh-air intake kitGroup control by Network Interface Module (NIM)External command control using BAGWired Remote Controller

Ceiling CassetteComfort

Auto-swingSwing PatternSwitchable fan speedProgramme “Dry”Timer Selector

Two selectable temperature sensor

*

* Applicable when wired controller is used

Weekly scheduled timer*

Indoor Unit FCRN50AXVL FCRN125AXVL9

Outdoor Unit RR50AGXVL RR125AGXTL9

Btu/hr 18,500 48,000

kW 5.42 14.07

Watts 1,730 5,100

A 7.9 14.8

Ph/V/Hz 3/220/60

COP W/W 3.13 2.76

22 10 24

Air Flow Rate (H/M/L/Q) cfm 730/620/510/360

Sound Pressure Level (H/M/L/Q) dBA 39/35/33/29 49/46/42/38

Deco Panel (H x W x D) mm

Machine Weight Kg

Sound Pressure Level dBA 66

Dimension (H x W x D) mm

Machine Weight Kg 87

Pipe Connection-Liquid mm

Pipe Connection-Gas mm 12.7

m

m

m

OUTDOOR

Maximum Piping Length

Minimum Piping Length

Maximum Piping Elevation

Power Supply

Model Name

Rated Cooling Capacity (Min. ~ Max.)

Power Consumption

Total Running Current

1/220/60

INDOOR

43

15

30

651 x 855 x 328

50

6.4

Unit Dimension (H x W x D) mm

Decorative Panel

m

g/m

Chargeless Refrigerant

Additional Refrigerant Charge

FCRN71AXVL

RR71AGXVL

29,500

8.65

3,130

14.3

2.76

890/760/620/490

43/41/36/34

57

753 x 855 x 328

57

25

3

BC50F2XWA

7.5

30

15.9

30

1120/1030/890/760

343 x 950 x 950

30

852 x 1030 x 400

FCRN100AXVL

RR100AGXVL

36,000

10.55

3,700

16.8

2.85

48/45/41/37

61

71

50

9.5

288 x 840 x 840

FCRN60AXVL

RR60AGXVL

24,000

7.03

2,400

11

2.93

840/700/560/440

41/38/35/32

301 x 950 x 950

27

246 x 840 x 840

Non-Inver ter

Page 4: Perfecting the Air - Daikin Philippines

ComfortSwitchable fan speed

Programme “Dry”

Timer Selector* Applicable when wired controller is used

Two selectable temperature sensor

*

Weekly scheduled timer*

CleanlinessWashablesaranet filter

Control FeaturesAuto random restart

Work & ServicingPre-charged for up to 7.5m

Self-Diagnosis

OthersAnti-corrosion treatedheat exchangers

OptionalGroup control by Network Interface Module (NIM)

External command control using BAG

Wired Remote Controller

Duct ConnectionStandard Static Pressure Type

Indoor Unit FDMRN50AXVL FDMRN60AXVL

Outdoor Unit RR50AGXVL RR60AGXVL

Btu/hr 18,500 23,500kW 5.42 6.89

Watts 1,730 2,400

A 7.9 11

Ph/V/Hz

COP W/W 3.13 2.87

Air Flow Rate(H/M/L) cfm 590/520/320 690/570/440 1580/1330/1180

External Static Pressure Pa

Sound Pressure Level(H/M/L) dBA 40/38/33 42/40/39

Dimension (H x W x D) mm 261 x 1,065 x 411 261 x 1,200 x 411

Machine Weight Kg 24 26

Sound Pressure Level dBA

Dimension (H x W x D) mm

Machine Weight KgPipe Connection-Liquid mm

Pipe Connection-Gas mm 12.7

m

m

m

FDMRN71AXVL

RR71AGXVL

29,0008.5

3,330

15.3

2.55

900/830/640

47/45/42

378 x 999 x 541

42

57

753 x 855 x 328

57

3

25

Total Running Current

Power Supply 1/220/60

Model Name

Rated Cooling Capacity (Min. ~ Max.)

Power Consumption

INDOOR

Maximum Piping Length

Minimum Piping Length

Maximum Piping Elevation

100

9.5

50

OUTDOOR

FDMRN125AXVL9

RR125AGXTL9

48,00014.075,520

15.6

1540/1280/1100

51/48/46

378 x 1,369 x 541

50

87

3/220/60

66

2.55

30

852 x 1030 x 400

30

15

50

6.4

50

651 x 855 x 328

43

m

g/m 10

Chargeless Refrigerant

Additional Refrigerant Charge 24

FDMRN140AXVL9

RR140AGXTL9

56,00016.416,590

19.5

52/50/47

378 x 1,569 x 541

56

5

101

19.05

2.49

5022

FDMRN100AXVL

RR100AGXVL

36,00010.554,000

18.2

2.64

1250/980/780

50/47/43

378 x 1,115 x 541

44

61

71

30

15.9

7.5

CleanlinessWashable saranet filter

Work & ServicingPre-charged for up to 7.5m

Self-Diagnosis

Control FeaturesAuto random restart

OthersAnti-corrosion treatedheat exchangers

Comfort

Switchable fan speed

Programme “Dry”

Timer Selector * Applicable when wired controller is used

Two selectable temperature sensor

*

Weekly scheduled timer*

Horizontal Auto-swing

Floor Standing

Indoor Unit FVRN71AXVL

Outdoor Unit RR71AGXVL

Btu/hr 29,000

kW 8.5

Watts 3,130

A 13.7

Ph/V/Hz

COP W/W 2.72

Air Flow Rate (H/M/L) cfm 675 / 625 / 530

Sound Pressure Level (H/M/L) dBA 44 / 42 / 39

Dimension (H x W x D) mm 1,850 x 600 x 270

Machine Weight Kg 42

Sound Pressure Level dBA 57

Dimension (H x W x D) mm 753 x 855 x 328

Machine Weight Kg 57

5

Pipe Connection-Liquid mm

Pipe Connection-Gas mm

m

m 25

Maximum Piping Length

mMinimum Piping Length

Model Name

Power Supply

Total Running Current

Rated Cooling Capacity (Min. ~ Max.)

Power Consumption

INDOOR

Maximum Piping Elevation

OUTDOOR

1/220/60

9.5

50

3/220/60

66

FVRN125AXVL9

RR125AGXTL9

48,000

14.07

5,000

14.5

2.81

1035 / 935 / 835

50 / 48 / 46

48

87

30

1,850 x 600 x 350

852 x 1030 x 400

FVRN140AXVL9

RR140AGXTL9

56,000

16.41

6,240

18.8

2.63

1170 / 1085 / 985

54 / 53 / 51

51

50

101

19.05

m

g/m 30 30 24

Chargeless Refrigerant

Additional Refrigerant Charge

7.5

FVRN100AXVL

RR100AGXVL

36,000

10.55

3,800

17.3

2.78

1035 / 945 / 845

49 / 47 / 44

45

61

71

3

15.9

Non-Inver ter

Page 5: Perfecting the Air - Daikin Philippines

Controller

Wired controller BRC51A621

2

6

789

11

10

3

4

5

Wireless controller BRC52A62

1

2

3

5

6

789

10

11

4

Auto-swing (Not applicable

for Suspended type)

Selectable mode:

Cool, Dry, Fan

7

Turbo function8

Quiet function9

On timer setting10

Real time clock11

61

3

4

5

2 Fan speed selection:

Low, Medium, High, Auto

Temperature setting:

Up & down

Sleep mode function

“Glow-in-the-dark”

on / off switch

Off timer setting

Wired controller BRC51A62 can directly be connected to the unit’s main board to start operating without extra setting or modi�cation. It also has a built-in temperature sensor that enables temperature sensing closer to target area for improved comfort (no settings required to activate the handset temperature sensor).

IR receiver on wired handsetreceived the signal

Signal sent fromwireless handset

2 Temperature operate

in ˚C and ˚F3 Swing function

4 Sleep mode function

1 Real time clock and

day display Turbo function7

Cool, Dry, Fan mode8

Delay timer (1 or 2 hours)9

7-days programmable timer10

On / Off Switch6

11 Low, Medium, High,

Auto fan speed

5 Sleep function

Page 6: Perfecting the Air - Daikin Philippines

● Speci�cations, designs, and other content appearing in this brochure are current as of June 2020 but subject to change without notice.● 1 year warranty for parts and labor | 5 years warranty for compressor only (Labor and Consumables are chargeable after 1 year).

www.daikin.com.ph

Authorized DealerTel No.: (02) 5318 - 6800 | Customer Service: (02) 5318 - 6820

Branches:ILOCOS Tel No.: (077) 600 - 2720DAGUPAN Tel No.: (075) 615 - 2791NAGA Tel Fax: (054) 871 - 4177

ILOILO Tel Fax: (033) 323 - 2340CEBU Tel No.: (032) 348 - 0085CDO Tel Fax: (088) 868 - 6800DAVAO Tel Fax: (082) 285 - 6008

[email protected] Daikin Philippines

DPH-SANINV-062020D

Network Controls

Group control by NetworkInterface Module (NIM)

For simultaneous controlof up to 16 indoor units

For sequential control of 2 indoor units at alternatesequence of pre-set hour

Operation and surveillanceis carried out using thecontact signal from theoperation control box inthe building surveillance(security) room.

Sequential control bySequential Network

Interface Module (S-NIM)

Control by externalcommand using BAG

Control Pattern Remote Controls

S-NIM S-NIM

BAG

BMS

BAG BAG

NIM NIM NIM NIM