AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 1 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
PD 442KNXTC4
KONNEX TOUCH TRANSMITTER 1 4 CHANNELS 2m S44 PRODUCT DESCRIPTION
1. Introduction
The code 442KNXTC4 implements both the communication part (physical + data-link layer) and the application part of one/four Konnex points. The application part detects the rising and falling edges of the available touch buttons and transfers this information, together with the operating mode (hereinafter called "function") to the communication part, which manages the logical and physical interface with the line Konnex. The 442KNXTC4 is built in a two-module "hidden" enclosure of the System 44, and is mechanically compatible with all other devices of the same system. It is intended to be installed on the back of finishing plates.
2. Characteristics
The characteristics are described with reference to fig.1:
fig. 1a fig. 1b fig. 1c
P1
- + BUS
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 2 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
2.1. Internal structure
fig. 2 2.2. Mechanics
Enclosure: 2 “hidden” modules S44 (45 l x 45 h x 29 d) mm, to be completed with glass or aluminium plate.
Protection Degree: IP20; IP40 when installed Mass: 34g Compatible with all elements of the system 44.
2.3. Connections
2 pole removable terminal standard Konnex TP1 (red + black) Wire insulation stripping: 6mm Clamping: spring Capacity: 4 x rigid wire; 0,6mm < < 0,8mm; Terminal -: GND Terminal +: BUS positive
2.4. Environmental conditions
Reference temper. and relative humidity: 25°C RH 65% Operating amb. temp. range: from -5°C to +45°C Maximum Relative Humidity: 90% at 35°C Maximum Height: 2000m a.s.l.
2.5. Power supply 2.5.1. Rated voltage
V = 29 VDC (SELV Konnex power supply)
KNX
POWER SUPPLY TOUCH
APPLICATION UART
DC/DC PS
UART
KNX
AVE KNX PRODUCT & RELATED DATA-BASE
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 3 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
2.5.2. Max absorption 12,7 mAMAX with four active LED optical signals purple color 11,6 mAMAX with four active LED optical signals blue color 11,5 mAMAX with four active LED optical signals blue color amber 10,5 mAMAX without active LED optical signals
2.6. Sensitive front area
The front area is divided into nine sensitive areas. In programming phase, it is possible to choose the areas which can be activated (a max of four) and which functions assign to each area.
2.7. Configuration and installation
The device can be configured by using the application program ETS (Engineering Tool Software) and the application program 442KNXTC4AP, made available by Ave. No additional software tools or plugins are required. For more information on ETS, visit also www.knx.org.
2.7.1. Configuration
The functionality of the device depends on the settings determined by ETS4 (or later) and the application program Ave AP442KNXTC4 ##. Knxprod (## = version), which can be downloaded from the www.ave.com site. With the application program, it is possible to upload the device in a new project and configure all the product operation parameters, which will be described in detail later in this manual.
2.7.2. P1 programming Button
It is accessible by means of a 3x1mm slotted screwdriver, through the opening specially crafted on the side of the device (see fig.1b). It allows the programming of the device (see par. 3).
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 4 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3. Structure of the application program The structure of the application program is schematically shown in the flow chart in fig.3. In the continuation of this document, N indicates the umpteenth key/LED of the capacitive keyboard: therefore, the object of communication
1+ (N-1): Key N - Switching It is meant to be intended as a summary of the following communication objects:
1: Key 1 – Switching 2: Key 2 – Switching 3: Key 3 – Switching 4: Key 4 – Switching
Bold values are those proposed by default.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 5 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Fig. 3
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 6 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.1. General section 3.1.1. Active columns
The front of the device is divided into nine positions, grouped into three columns of three positions. The central column (2) is an alternative to the two outer columns (1 and 3). The product is configured by default with the active central column (fig. 4b).
fig. 4a fig. 4b
Parameter Name Conditions Values Number of columns Always present 1 = Only central column is active
2 = The external columns are active The parameter is set during the installation phase and cannot be modified during normal operation by means of a communication object.
3.1.2. Positions
For each column, it can be activated either the central position (internal) or the two positions at the top and at the bottom (externals). Therefore, it is possible to have a minimum of zero active positions and a maximum of four. With one colums (central):
fig. 5a fig. 5b fig. 5c
1 3
2
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 7 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter Name Conditions Values
Positions column Number of columns = 1 None Internal Externals
When the parameter is set to "None", no key or LED results active for that column. In the images 5b and 5c are represented the possible positions of the electrodes that could be already enabled. The parameter is set during the installation phase and cannot be modified during normal operation.
With two columns:
fig. 5d fig. 5e fig. 5f fig. 5g fig. 5h fig. 5i fig. 5m fig. 5n fig. 5p
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 8 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter Name Conditions Values
Positions column 1 Number of columns = 2 None Internal Externals
When the parameter is set to "None", no key or LED results active for that column. Parameter Name Conditions Values
Positions column 2 Number of columns = 2 None Internal Externals
When the parameter is set to "None", no key or LED results active for that column. 3.1.3. Areas/channels numeration
The automatic assignment of the number for each active position follows the progressive numeration criterion, starting from the first position at the top left and descending to the bottom, and then doing the same thing in the right column. Here below the possible combinations of active positions, with the corresponding number assignment: With one column:
fig. 6a fig. 6b
1 1
2
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 9 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
With two columns: fig. 6c fig. 6d fig. 6e fig. 6f fig. 6g fig. 6h fig. 6i fig. 6m 3.1.4. Keys sensibility control
It is possible to modify the sensibility to the "touch" according to two levels: High sensibility: for a touch detection up to 5 mm Low sensibility: for a contact detection
Parameter Name Conditions Values
Keys sensibility control Always present Disable Enable
In "Enable" the parameter executes the activation of the one bit objects:
150: Keys sensibility – Set 151: Keys sensibility – Status
With these, it is possible to remotely monitor and report the touch sensibility of all electrodes set as active on the keyboard. This parameter is unique and shared by all the electrodes.
1
1
1
2 1
2
1
2
1 2
3
1
2 3
1
2
3
4
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 10 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter Name Conditions Values
Keys sensibility Keys sensibility control = Enable Low High
It is possible to set the degree of sensibility of the electrodes by means of ETS: this setting can be overwritten when receiving the communication object:
150: Keys sensibility – Set
3.1.5. Led brightness
For each active position it’s possible to have an optical signal. Its brightness level is programmable with ETS. 100% : aligned with all other Ave Touch controls 60% : reduced brightness 30% : night mode 0% : off
Parameter name Conditions Values
LED positions Always present Disable Enable
By setting this option to "Disable", all the position LED are forced OFF (this setting is revoked by using the communication object:
152: LED positions – Enable. The communication object:
153: LED positions - Enable Status notifies instead the current status of the LED.
Parameter name Conditions Values Positions in OFF LED positions = Disable All
OFF state By setting this parameter to "All", all the optical signals are switched OFF. By setting this parameter to "OFF state", only the optical signals that are in the OFF state are switched off, while the others remain active, alarms included.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 11 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
LED mode Always present Night = 30% Day = 60% or 100%
This parameter defines the brightness level of the active LED: the choice between the brightness at 60% or 100% is done by using the parameter "LED brightness". To this parameter are associated the two communication objects:
154: LED Mode – Set day/night 155: LED Mode - Day/night status
with which it is possible to respectively force and notify the night/day status of the LED.
Parameter name Conditions Values LED brightness LED mode = Day Reduced = 60%
Standard = 100% This parameter defines the brightness level to 60% or 100% of the active LED. To this parameter are associated the two communication objects:
156: LED brightness – set standard/reduced 157: LED brightness - standard/reduced status
with which it is possible to respectively force and notify the standard/reduced LED brightness.
The combination of the settings and their effect are summarized in the following table: LED positions LED mode LED brightness % Brightness 0 = Disable X X 0 1 = Enable 1 = Night X 30 1 = Enable 0 = Day 1 = Reduced 60 1 = Enable 0 = Day 0 = Standard 100
3.1.6. Acustic signallings At the command recognition, the device emits a short confirmation sound (click). It is possible to deactivate it by appropriately programming the corresponding parameter with ETS. Other two different acoustic signals can also be activated by a communication object coming from the Bus, for example when a generic alarm activates or there is a call at the entrance of the house. The interruption of the acoustic signal will take place at the reception of a different object of communication, or at the touch of any of the front keys.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 12 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values Keys click Always present Disable
Enable This parameter enables or excludes the functionality of the acoustic feedback when pressing the key. To this parameter are associated the two communication objects:
158: Keys click - Enable 159: Keys click - Enable Status
with which it is possible to respectively enable and notify the enable status of the acoustic click of the keys.
Parameter name Conditions Values Buzzer call function Always present Disable
Enable This parameter activates or excludes the functionality of the acoustic call feedback. To this parameter are associated the following communication objects:
160: Buzzer call – Enable 161: Buzzer call – Enable status 162: Buzzer call – Activate 163: Buzzer call – Activate status
For the signaling to appear activated, first it must be enabled and then activated by the communication objects 160 and 162. The two status objects allow notifying to a supervisor of the enable and activate status of the acoustic signal.
Parameter name Conditions Values Buzzer alarm function Always visible Disable
Enable This parameter activates or excludes the functionality of the acoustic alarm feedback. To this parameter are associated the following communication objects:
164: Buzzer alarm – Enable 165: Buzzer alarm – Enable status 166: Buzzer alarm – Activate 167: Buzzer alarm – Activate status
For the signaling to appear activated, first it must be enabled and then activated by the communication objects 164 and 166. The two status objects allow notifying to a supervisor of the enable and activate status of the acoustic signal.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 13 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
The activation of the alarm condition appears to have priority over the call condition. Therefore, if a call signal were in execution, the alarm could impose itself: the opposite is not possible.
3.1.7. Plate cleaning function (temporary inhibition)
To enable the cleaning of the front glass plate without continuous activations of the associated outputs, it is possible to temporarily inhibit the operation of the device by sending to it a temporary exclusion message. The function can be excluded in advance, during installation phase by means of the ETS application.
Parameter name Conditions Values Keypad lock Always present Disable
Enable With this parameter it is possible to access the activation object:
168: Keypad lock – Activate to gain access to plate cleaning (temporary inhibition of the keys). The activation status of plate cleaning is notified with the communication object:
169: Keypad lock – Activate status
Parameter name Conditions Values Lock message value Keypad lock= Enable Message 0
Message 1 This parameter decides the logical value to associate with the keypad lock enable object, in order to gain access to plate cleaning function.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 14 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.1.8. Communication objects of the General section
N° Object name Object function Condition 150 Keys sensibility Set Keys sensibility control = Enable 151 Keys sensibility Status Keys sensibility control = Enable 152 LED position Enable Always present 153 LED position Enable status Always present 154 LED mode Set day/night Always present 155 LED mode Day/night status Always present 156 LED brightness Set standard/reduced Always present 157 LED brightness Standard/reduced status Always present 158 Keys click Enable Always present 159 Keys click Enable status Always present 160 Buzzer call Enable Always present 161 Buzzer call Enable status Always present 162 Buzzer call Activate Always present
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 15 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
163 Buzzer call Activate status Always present 164 Buzzer alarm Enable Always present 165 Buzzer alarm Enable status Always present 166 Buzzer alarm Activate Always present 167 Buzzer alarm Activate status Always present 168 Keypad lock Activate Keypad lock = Enable 169 Keypad lock Activate status Keypad lock = Enable
3.2. Configuration parameters of the Position N - Key N section
It is possible, for each active position, to have the presence of a capacitive touch control, assigning it different actions to a short touch or to a long one (by using ETS software for timing configuration), to achieve: on/off command, dimming, shutters management, scene, lock, sending incremental commands, sending values, etc.: This is only the list of the main possible functions, it is not an exhaustive one. only feedback: led active, non active button ON / OFF Shutter Up/Down Shutter Stop Shutter adjustable rotating blades / stop rotation Dimmer ON/OFF Dimming Scene Send value (set between 0 and 255) Send two values Send priority (Forcing or Lock)
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 16 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Key function N Key position = active
Disable Switching Dimmer Scene Shutters and blinds Send value Control value
The parameter allows to select the function which will be associated with the selected key. By activating the function, the communication objects are made available for purposes that will be described in detail in the respective parameter of this document.
In addition to blocking the entire keyboard, seen in the General section, you can selectively lock the functionality of each key, regardless of the associated function. The following description is also valid for all the functions that will be described below: Switching, Dimmer, Scenario, Shading, etc. Parameter name Conditions Values
Function lock Key function N ≠ disable Disable Enable
The parameter inserts the object for enabling/inhibiting the function associated with the key:
91+(N-1): Key N - Enable function lock The enable status can be notified remotely (for example to a supervisor) via communication object:
97+(N-1): Key N - Function lock enable status Parameter name Conditions Values
Lock message value Key function N ≠ disable Function lock = Enable
Message 0 Message 1
It establishes the logical level to be associated with the function lock enable object. Message 0 = Activation when receiving value 0 Message 1 = Activation when receiving value 1
Object name Communication object function Condition N°
object Key N Enable function lock Lock function = Enable 91+(N-1) Key N Function lock enable status Lock function = Enable 97+(N-1)
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 17 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.2.1. Switching key function
Button (channels managed individually) ON/OFF cyclic (step): short touch
ON/OFF Short touch
Button (channels managed in pairs) ON: Short touch
OFF: Short touch
ON Short touch OFF Short touch
Parameter name Conditions Values Press and release mode Key function N = Switch Disable
Enable By enabling the parameter, it sends the switching on (ON) command to the pressure and the switching off (OFF) one at the release. When the "Press and release mode" is enabled, the "Short press mode" parameter is made inaccessible. For each key enabled with this function, is generated the group object:
1+(N-1): Key N – Switching
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 18 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Short press mode Key function N = Switch Press and release mode = Disable
ON OFF ON/OFF
It establishes the command that must be sent at the front of the keypress. For each key enabled with this function, is generated the group object:
1+(N-1): Key N – Switching If the “Long press mode” is not set to "None", the sending of the object takes place in correspondence of the keypress, otherwise in correspondence of the key release one.
Parameter name Conditions Values
Long press mode Key N function = Switching Press and release mode = Disable
None ON OFF ON/OFF Recall scene
Establishes the command that must be sent in correspondence of the key release. For each key enabled with this function, is generated the group object:
7+(N-1): Key N – Switching (long press)
Channels managed individually Send switching at short touch In combination with Send a scene number that can be found in
the memory of the actuators in the event of
prolonged/long touch
Send On/Off Short touch Send Long touch Scene
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 19 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Scene number
Key function N = Switch Press and release mode = Disable Long press mode = Recall scene
1 [In the range 1…64]
It establishes the command that must be sent to the recognition of key pressure front. For each key enabled with this function, is generated the group object:
31+(N-1): Key N – Scene (long press)
Parameter name Conditions Values
Long press time
Key function N = Switch Press and release mode = Disable Long press mode = Recall scene
0,5s 1s 1,5s 2s 2,5s 3s 4s 5s 7s 10s
It establishes the duration for the recognition of the key long press.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 20 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
For a toggle command (ON / OFF), a communication object was created to align the various command points:
Parameter name Conditions Values Status group objects Key function N = Switch Disable
Enable If enabled, the communication object:
13+(N-1): Key N - Switching status is exposed. The command sent with the object “1+(N-1): Key N – Switching” is consequent to the status feedback object associated with the receiver.
Object name Object function Conditions N°
object Key N Switching Key function N = Switch 1+(N-1)
Key N Switching (long press) Key function N = Switch Long press mode ≠ None 7+(N-1)
Key N Switching status Key function N = Switch Status group objects = Enable 13+(N-1)
Key N Switching status (long press) Key function N = Switch Long press mode ≠ None Status group objects = Enable
19+(N-1)
Key N Scene (long press) Key function N = Switch Long press mode = Recall scene
31+(N-1)
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 21 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.2.2. Dimmer key function Channels managed individually ON/OFF cyclic (step): Short touch
Dimming +, Dimming -: cyclic,
continuous touch
Stop dimming: continuous touch
interruption
ON/OFF Short touch + / - continuous touch STOP
Channels managed in pairs ON: Short touch
OFF: Short touch
Dimming + : continuous touch
Dimming - : continuous touch
Stop dimming: continuous touch
interruption
ON Short touch OFF Short touch + continuous touch - continuous STOP touch
Parameter name Conditions Values
Long press mode Key function N = Dimmer Increase Decrease Increase/Decrease
It establishes the command that must be sent at the recognition of a long press event. The communication object associated is:
25+(N-1): Key N – Dimming
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 22 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Long press time Key function N = Dimmer
0,5s 1s 1,5s 2s 2,5s 3s 4s 5s 7s 10s
It establishes the duration for the recognition of the key long press. Parameter name Conditions Values
Dimmer increase Key function N = Dimmer
1% 3% 6% 12% 25% 50% 100%
It sets the step of increase of dimming sent to the actuator. Similarly to the ON / OFF switching function (see previous paragraph), even for the Dimmer function, in the Increment / Decrement mode, you must align the various control points.
Parameter name Conditions Values Status group objects Key function N = Dimmer Disable
Enable If enabled, the communication object:
13+(N-1): Key N - Switching status is exposed. In this case the command sent with the object “1+(N-1): Key N – Switching” is consequent to the status feedback object associated with the receiver.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 23 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Object name Object function Conditions N° object Key N Switching Key function N = Dimmer 1+(N-1)
Key N Switching status Key function N = Dimmer Status group objects = Enable 13+(N-1)
Key N Dimming Key function N = Dimmer 25+(N-1) The dimming object is used to send a change of intensity (increase or decrease) to a dimmer actuator. Three values are used and they correspond to the commands: increase start 100%, decrease start 100%, stop variation. The increase / decrease commands are sent following a long press; the stop follows the release of the key. The value sent during activation can always be the same value or alternate between the two possible values (up / down) at every activation.
0 0 0 11
Decrease 100%
1 0 0 1Increase 100%
3 2 1 0 Bit Number
X 0 0 0 Stop
Direction: 1 = Increase 0 = Decrease
Amplitude (001b…111b) o Stop (000b)
4 Bit
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 24 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.2.3. Scene key function Channels managed individually Send a scene number that can be found in
the memory of the actuators: short touch
Save scene: touch maintained (e.g.) for 10s.
Note: all actuators equipped with this scene
number will save their status in this moment.
Send scene Short touch Save Long scene touch
Parameter name Conditions Values
Scene number Key function N = Scene 1 [in the range 1…64]
It establishes the command that must be sent to the recognition of the key short press. For each key enabled with this function, is generated the group object:
31+(N-1): Key N - Scene
Parameter name Conditions Values Long press mode Key function N = Scene None
Save scene It allows saving the scene on the actuators when it detects a key long press. The generated group object remain:
31+(N-1): Key N – Scene
However, save bit 7 is modified as described below.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 25 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Long press time Key function N = Scene
0,5s 1s 1,5s 2s 2,5s 3s 4s 5s 7s 10s
It establishes the time for the recognition of the key long press for the scene saving.
Object name Object function Conditions N° object Key N Scene Key function N = Scene 31+(N-1) Saves or recalls a scene. The lower 6 bit in the code byte represents the scene number, while the highest bit is the operation code (save or recall).
7 6 5 4 Bit Number
3 2 1 0
1 Byte
0 = recall, 1 = save
Scene Number (1-64)
Not used
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 26 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.2.4. Shutters and blinds function Channels managed separately Start Up/Down: cyclic, with long touch
Stop: Short touch
/ Long STOP Short touch touch
Channels managed in pairs Start Up / Stop: cyclic, with short touch
Start Up /Stop: cyclic, with short touch
Blades orientation: continuous touch
Stop blades orientation: stop continuous
touch
/STOP Short touch /STOP Short touch Long touch Long STOP touch
Parameter name Conditions Values
Short press mode Key function N = Shutters and blinds
Disable Up + stop Down + stop Up/down + stop Up Down Up/down Stop Open slats Close slats
It establishes the command that must be transmitted on the front of pressure or quick key release. If the "Long press mode" appears to be disabled, the message sending always occurs on the front of pressure instead of the release one. The communication objects interested in sending the command are:
1+(N-1): Key N - Shutter stop 7+(N-1): Key N - Shutter move
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 27 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Long press mode Key function N = Shutters and blinds
Disable Up Down Up/down Stop Open slats Close slats Open/close slats
It establishes the command that must be sent to the recognition of a long press event. The communication object interested in sending the command is the same as for the short press:
1+(N-1): Key N - Shutter stop 7+(N-1): Key N - Shutter move
Note. With the values: Open slats, Close slats and Open/close slats, for the duration of the push of the button over the long press, the same command is repeatedly sent at 1 s interval.
Parameter name Conditions Values Release after long press mode Key function N = Shutters and blinds
Long press mode ≠ Disable Disable Stop
It establishes the command that must be sent on the front of key release, after recognizing a long press event. The communication object interested in sending the stop command are the same as for the short/long press:
1+(N-1): Key N - Shutter stop
Parameter name Conditions Values
Long press time Key function N = Shutters and blinds Long press mode ≠ Disable
0,5s 1s 1,5s 2s 2,5s 3s 4s 5s 7s 10s
It establishes the time for the recognition of the key long press.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 28 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Object name Object function Conditions N° object Key N Shutter stop Key function N = Shutters and blinds 1+(N-1) Key N Shutter move Key function N = Shutters and blinds 7+(N-1)
3.2.5. Send value function (brightness level, position of the roller shutters, the slats, etc.)
Channels managed individually Send value: Short touch
Send a value between 0 and 255.
Eg.: brightness = 33% (value 85)
Send Short touch value
Short touches in sequence: sending
incremental commands. The chosen
commands are sent one after the other
(increase or decrease between a minimum
and maximum value, comprised between 0
and 255) Example: 1° touch: comfort (command1); 2° touch: stand-by (command2); 3° touch: eco (command 3); 4° touch: comfort (command1)
Send Short Command touch
3° Touch: Eco
2° Touch: Stand-by
1° Touch : Comfort
4° Touch: …
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 29 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Values number Key function N = Send value
1 2 3 4
It establishes the number of the set of values that will be sent in sequence, at every short press of the key.
Parameter name Conditions Values Value 1 Key function N = Send value
Values number ≥ 1 1 [in the range 0..255]
It establishes the value that is going to be transmitted with the status object:
37+(N-1): Key N – Send value
Parameter name Conditions Values Value 2 Key function N = Send value
Values number ≥ 2 2 [in the range 0..255]
It establishes the value that is going to be transmitted with the status object:
37+(N-1): Key N – Send value
Parameter name Conditions Values
Value 3 Key function N = Send value Values number ≥ 3
3 [in the range 0..255]
It establishes the value that is going to be transmitted with the status object:
37+(N-1): Key N – Send value
Parameter name Conditions Values Value 4 Key function N = Send value
Values number = 4 4 [in the range 0..255]
It establishes the value that is going to be transmitted with the status object:
37+(N-1): Key N – Send value
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 30 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Channels managed individually Send 1° value: short touch
Send a value comprised between 0 and 255.
Eg.: brightness = 10% (value 25)
Send 2° value: long touch
Send a value comprised between 0 and 255.
Eg.: brightness = 50% (value 127)
Send Short touch Value 1 Send Long Value 2 touch
Parameter name Conditions Values
Long press mode Key function N = Send value Disable Enable
If enabled, introduces the object :
43+ (N-1): Key N - Send value (long press) for the transmission of the value also at the recognition of a key long press.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 31 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Long press time Key function N = Send value Long press mode = Enable
0,5s 1s 1,5s 2s 2,5s 3s 4s 5s 7s 10s
It establishes the time for the recognition of the key long press.
Parameter name Conditions Values
Values number Key function N = Send value Long press mode = Enable
1 2 3 4
It establishes the number of the set of values that will be sent in sequence, at every key long press.
Parameter name Conditions Values
Value 1 Key function N = Send value Long press mode = Enable Values number ≥ 1
1 [in the range 1..255]
It establishes the value that is going to be transmitted with the status object: 43+(N-1): Key N – Send value (long press )
Parameter name Conditions Values
Value 2 Key function N = Send value Long press mode = Enable Values number ≥ 2
2 [in the range 1..255]
It establishes the value that is going to be transmitted with the status object: 43+(N-1): Key N – Send value (long press )
Parameter name Conditions Values
Value 3 Key function N = Send value Long press mode = Enable Values number ≥ 3
3 [in the range 1..255]
It establishes the value that is going to be transmitted with the status object : 43+(N-1): Key N – Send value (long press )
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 32 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Value 4 Key function N = Send value Long press mode = Enable Values number ≥ 4
4 [in the range 1..255]
It establishes the value that is going to be transmitted with the status object: 43+(N-1): Key N – Send value (long press )
Object name Object function Conditions N°
object Key N Send value Key function N = Send value 37+(N-1) Key N Send value (long press ) Key function N = Send value 43+(N-1)
3.2.6. Function - Control value (lock) Channels managed in pairs Lock ON: Long touch Lock OFF: Long touch Unlock ON: Short touch Unlock OFF: Short touch
Example: with a long touch, "Lock ON", the actuator output remains locked "ON" until the unlock short touch ("unlock ON ", exit with "ON" state and " unlock OFF ", exit with "OFF " state).
Lock ON OFF Long touch Unlock ON OFF Short touch
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 33 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Short press mode Key function N = Control value
No control, OFF No control, ON Control, OFF Control, ON
It establishes the command that is going to be sent when detecting a short press of the button. The first two selection items correspond to the on/off control, while the control ones also imposes the forcing (in addition to the command). The communication object associated with this command is:
49+(N-1): Key N – Control
Parameter name Conditions Values
Long press mode Key function N = Control value
No control, OFF No control, ON Control, OFF Control, ON
It establishes the command that is going to be sent, when detecting a long press of the button. The considerations made for the previous parameter also apply for this one.
Parameter name Conditions Values
Long press time Key function N = Control value
0,5s 1s 1,5s 2s 2,5s 3s 4s 5s 7s 10s
It establishes the time for the recognition of the key long press event.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 34 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Object name Object function Conditions N° object Key N Control Key function N = Control value 49+(N-1) The group object of Switch Control type (priority or forcing) has a 2 bit size. If the 2 bit value of the object is 0 or 1 (therefore, the bit to the left is zero), the addressed actuator is normally controlled by means of the communication object. If the priority value of the object is 2 (therefore, the bit on the left is one and the right one is zero), the output will be deactivated or activated when the value is 3 (both bits are 1). The communication object value in this case is ignored, as long as the forcing is not removed.
1 0
0 = no forcing, 1 = forcing
Switching On/Off
Bit Number
2 Bits
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 35 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.3. Configuration parameters of the Position N - LED N section On the front are visible from one to four optical signals in correspondence with each active position. When receiving status feedback from the receivers, the LED can be programmed by using the ETS in order to choose a certain color and status. When approaching the finger to the front of the device, the intensity of the LED light increases: The possible colors are blue, red-amber and purple. The possible status are: ON Blinking (duty 50% and TON=TOFF can be set between 0,5s e 10s) OFF
Parameter name Conditions Values LED N Position N = activated Disable
Enable Parameter used to enable the light signal. It activates the communication object:
55+(N-1): LED N - Set ON/OFF
Parameter name Conditions Values
OFF color Led N = Enable
OFF Blue Red Purple
It sets the color to associate to the off status
Parameter name Conditions Values OFF mode Led N = Enable
OFF color ≠ OFF Steady Blink
It sets the blink or steady mode for the signaling of the OFF status.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 36 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
OFF blink period
Led N = Enable OFF Color ≠ OFF OFF mode = Blink
0,5 s 1 s 1,5 s 2 s 2,5 s 3 s 3,5 s 4 s 4,5 s 5 s 5,5 s 6 s 6,5 s 7 s 7,5 s 8 s
It sets the blinking period of the signaling of the OFF status.
Parameter name Conditions Values
ON color Led N = Enable
OFF Blue Red Purple
It sets the color to associate to the ON status.
Parameter name Conditions Values
ON mode Led N = Enable ON color ≠ OFF
Steady Blink
It sets the blink or steady mode for the signaling of the ON status.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 37 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
ON blink period
Led N = Enable ON color ≠ OFF ON mode = Blink
0,5 s 1 s 1,5 s 2 s 2,5 s 3 s 3,5 s 4 s 4,5 s 5 s 5,5 s 6 s 6,5 s 7 s 7,5 s 8 s
It sets the blink period of the signaling of the ON status.
Parameter name Conditions Values
Alarm 1 color Led N = Enable
OFF Blue Red Purple
It sets the color that is going to be associated to the Alarm 1 status. If set to other than OFF, it enables the communication object for the activation of the alarm signal:
67+(N-1): LED N – Set alarm 1
Parameter name Conditions Values Alarm 1 mode Led N = Enable
Alarm 1 color ≠ OFF Steady Blink
It sets the blink or Steady mode for the signaling of the Alarm 1 status.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 38 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Alarm 1 blink period
Led N = Enable Alarm 1 color ≠ OFF Alarm 1 mode = Blink
0,5 s 1 s 1,5 s 2 s 2,5 s 3 s 3,5 s 4 s 4,5 s 5 s 5,5 s 6 s 6,5 s 7 s 7,5 s 8 s
It set the blink period for the Alarm 1 status.
Parameter name Conditions Values
Alarm 2 color Led N = Enable
OFF Blue Red Purple
It sets the color that is going to be associated to the Alarm 2 status. If set to other than OFF, it enables the communication object for the activation of the alarm signal:
79+(N-1): LED N – Set alarm 2
Parameter name Conditions Values
Alarm 2 mode Led N = Enable Alarm 2 color ≠ OFF
Steady Blink
It sets the blink or Steady mode for the signaling of the Alarm 2 status.
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 39 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Parameter name Conditions Values
Alarm 2 blink period
Led N = Enable Alarm 2 color ≠ OFF Alarm 2 mode = Blink
0,5 s 1 s 1,5 s 2 s 2,5 s 3 s 3,5 s 4 s 4,5 s 5 s 5,5 s 6 s 6,5 s 7 s 7,5 s 8 s
It set the blink period for the Alarm 2 status.
Parameter name Conditions Values
Status group objects Led N = Enable Disable Enable
Provides status indication of optical signals. It activates the following group objects:
61+(N-1): LED N –ON/OFF status 73+(N-1): LED N – Alarm 1 status Condition = Alarm 1 color ≠ OFF 85+(N-1): LED N – Alarm 2 status Condition = Alarm 2 color ≠ OFF
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 40 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
Object name Object function Conditions N° object
Led N Set ON/OFF LED N = Enable 55+(N-1)
Led N ON/OFF status LED N = Enable Status group objects = Enable 61+(N-1)
Led N Set Alarm 1 LED N = Enable Alarm 1 color ≠ OFF 67+(N-1)
Led N Alarm 1 status LED N = Enable Alarm 1 color ≠ OFF Status group objects = Enable
73+(N-1)
Led N Set alarm 2 LED N = Enable Alarm color 2 ≠ OFF 79+(N-1)
Led N Alarm 2 status LED N = Enable Alarm 2 color ≠ OFF Status group objects = Enable
85+(N-1)
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 41 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
3.4. Defining the data type of the communication objects (DPT)
N° ogg. Name - Object function Dim. Flags DPT
1 Key 1 - Switching 1 Bit C R W T - [1.001] Switch 1 Key 1 - Shutter stop 1 Bit C R W T - [1.007] Step 2 Key 2 - Switching 1 Bit C R W T - [1.001] Switch 2 Key 2 - Shutter stop 1 Bit C R W T - [1.007] Step 3 Key 3 - Switching 1 Bit C R W T - [1.001] Switch 3 Key 3 - Shutter stop 1 Bit C R W T - [1.007] Step 4 Key 4 - Switching 1 Bit C R W T - [1.001] Switch 4 Key 4 - Shutter stop 1 Bit C R W T - [1.007] Step 7 Key 1 - Shutter move 1 Bit C R W T - [1.008] UpDown 7 Key 1 - Switching (long press ) 1 Bit C R W T - [1.001] Switch 8 Key 2 - Shutter move 1 Bit C R W T - [1.008] UpDown 8 Key 2 - Switching (long press ) 1 Bit C R W T - [1.001] Switch 9 Key 3 - Shutter move 1 Bit C R W T - [1.008] UpDown 9 Key 3 - Switching (long press ) 1 Bit C R W T - [1.001] Switch
10 Key 4 - Shutter move 1 Bit C R W T - [1.008] UpDown 10 Key 4 - Switching (long press ) 1 Bit C R W T - [1.001] Switch 13 Key 1 – Switching status 1 Bit C - W - - [1.001] Switch 14 Key 2 – Switching status 1 Bit C - W - - [1.001] Switch 15 Key 3 – Switching status 1 Bit C - W - - [1.001] Switch 16 Key 4 – Switching status 1 Bit C - W - - [1.001] Switch 19 Key 1 – Switching status (long press ) 1 Bit C - W - - [1.001] Switch 20 Key 2 – Switching status (long press ) 1 Bit C - W - - [1.001] Switch 21 Key 3 – Switching status (long press ) 1 Bit C - W - - [1.001] Switch 22 Key 4 – Switching status (long press ) 1 Bit C - W - - [1.001] Switch 25 Key 1 - Dimming 3 Bit C R - T - [3.007] Control_Dimming 26 Key 2 - Dimming 3 Bit C R - T - [3.007] Control_Dimming 27 Key 3 - Dimming 3 Bit C R - T - [3.007] Control_Dimming 28 Key 4 - Dimming 3 Bit C R - T - [3.007] Control_Dimming 31 Key 1 - Scene 1 Byte C R - T - [17.001] Scene_Number 31 Key 1 - Scene (long press ) 1 Byte C R - T - [17.001] Scene_Number 32 Key 2 - Scene 1 Byte C R - T - [17.001] Scene_Number 32 Key 2 - Scene (long press ) 1 Byte C R - T - [17.001] Scene_Number 33 Key 3 - Scene 1 Byte C R - T - [17.001] Scene_Number 33 Key 3 - Scene (long press ) 1 Byte C R - T - [17.001] Scene_Number 34 Key 4 - Scene 1 Byte C R - T - [17.001] Scene_Number 34 Key 4 - Scene (long press ) 1 Byte C R - T - [17.001] Scene_Number 37 Key 1 – Send value 1 Byte C R W T - [5.010] Counter_Pulses 38 Key 2 – Send value 1 Byte C R W T - [5.010] Counter_Pulses 39 Key 3 – Send value 1 Byte C R W T - [5.010] Counter_Pulses 40 Key 4 – Send value 1 Byte C R W T - [5.010] Counter_Pulses 43 Key 1 – Send value (long press ) 1 Byte C R W T - [5.010] Counter_Pulses 44 Key 2 – Send value (long press ) 1 Byte C R W T - [5.010] Counter_Pulses 45 Key 3 – Send value (long press ) 1 Byte C R W T - [5.010] Counter_Pulses 46 Key 4 – Send value (long press ) 1 Byte C R W T - [5.010] Counter_Pulses
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 42 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
49 Key 1 – Control 2 Bit C R W T - [2.001] Switch_Control 50 Key 2 – Control 2 Bit C R W T - [2.001] Switch_Control 51 Key 3 – Control 2 Bit C R W T - [2.001] Switch_Control 52 Key 4 – Control 2 Bit C R W T - [2.001] Switch_Control 55 LED 1 – Set ON/OFF 1 Bit C R W T - [1.001] Switch 56 LED 2 – Set ON/OFF 1 Bit C R W T - [1.001] Switch 57 LED 3 – Set ON/OFF 1 Bit C R W T - [1.001] Switch 58 LED 4 – Set ON/OFF 1 Bit C R W T - [1.001] Switch 61 LED 1 – ON/OFF status 1 Bit C R - T - [1.001] Switch 62 LED 2 – ON/OFF status 1 Bit C R - T - [1.001] Switch 63 LED 3 – ON/OFF status 1 Bit C R - T - [1.001] Switch 64 LED 4 – ON/OFF status 1 Bit C R - T - [1.001] Switch 67 LED 1 – Set alarm 1 1 Bit C R W T - [1.001] Switch 68 LED 2 – Set alarm 1 1 Bit C R W T - [1.001] Switch 69 LED 3 – Set alarm 1 1 Bit C R W T - [1.001] Switch 70 LED 4 – Set alarm 1 1 Bit C R W T - [1.001] Switch 73 LED 1 – Alarm 1 status 1 Bit C R - T - [1.001] Switch 74 LED 2 – Alarm 1 status 1 Bit C R - T - [1.001] Switch 75 LED 3 – Alarm 1 status 1 Bit C R - T - [1.001] Switch 76 LED 4 – Alarm 1 status 1 Bit C R - T - [1.001] Switch 79 LED 1 – Set alarm 2 1 Bit C R W T - [1.001] Switch 80 LED 2 – Set alarm 2 1 Bit C R W T - [1.001] Switch 81 LED 3 – Set alarm 2 1 Bit C R W T - [1.001] Switch 82 LED 4 – Set alarm 2 1 Bit C R W T - [1.001] Switch 85 LED 1 – Alarm 2 status 1 Bit C R - T - [1.001] Switch 86 LED 2 – Alarm 2 status 1 Bit C R - T - [1.001] Switch 87 LED 3 – Alarm 2 status 1 Bit C R - T - [1.001] Switch 88 LED 4 – Alarm 2 status 1 Bit C R - T - [1.001] Switch 91 Key 1 – Enable function lock 1 Bit C R W T - [1.003] Enable 92 Key 2 – Enable function lock 1 Bit C R W T - [1.003] Enable 93 Key 3 – Enable function lock 1 Bit C R W T - [1.003] Enable 94 Key 4 – Enable function lock 1 Bit C R W T - [1.003] Enable 97 Key 1 – Function lock enable status 1 Bit C R - T - [1.011] State 98 Key 2 – Function lock enable status 1 Bit C R - T - [1.011] State 99 Key 3 – Function lock enable status 1 Bit C R - T - [1.011] State
100 Key 4 – Function lock enable status 1 Bit C R - T - [1.011] State 150 Keys sensibility – Set 1 Bit C R W T - [1.001] Switch 151 Keys sensibility – Status 1 Bit C R - T - [1.001] Switch 152 LED positions – Enable 1 Bit C R W T - [1.003] Enable 153 LED position – Enable status 1 Bit C R - T - [1.011] State 154 LED mode – Set day/night 1 Bit C R W T - [1.003] Enable 155 LED mode – Day/night status 1 Bit C R - T- [1.011] State 156 LED brightness – Set standard/reduced 1 Bit C R W T - [1.003] Enable 157 LED brightness – Standard/reduced status 1 Bit C R - T - [1.011] State 158 Keys click – Enable 1 Bit C R W T - [1.003] Enable 159 Keys click – Enable status 1 Bit C R - T - [1.011] State 160 Buzzer call – Enable 1 Bit C R W T - [1.003] Enable 161 Buzzer call – Enable status 1 Bit C R - T - [1.011] State
AGGIORNATO 01 VARIANTE N° ESEGUITO R.S. PEL ESEGUITA APPROVATO D.R. DT APPROVATA DATA 05-09-17 DATA
SEZIONE DOC 50 KONNEX TOUCH KEYBOARD 1 4 CH. 2m S44 – 442KNXTC4 FILE PD442KNXTC4 PRODUCT DESCRIPTION DATA 23-02-17 CONTR. R.S. PEL PAG. N° DI PAGG. N° DIS. N°
DIS. R.C. PEL APPR. D.R. DT 43 43 PD 442KNXTC4 LA PROPRIETA’ DI QUESTO DISEGNO E’ RISERVATA A TERMINI DI LEGGE CON DIVIETO DI RIPRODUZIONE O DI COMUNICAZIONE A TERZI SENZA PREVENTIVA AUTORIZZAZIONE SCRITTA – rel. 02 – 01/01
162 Buzzer call – Activate 1 Bit C R W T - [1.003] Enable 163 Buzzer call – Activate status 1 Bit C R - T - [1.011] State 164 Buzzer alarm – Enable 1 Bit C R W T - [1.003] Enable 165 Buzzer alarm – Enable status 1 Bit C R - T - [1.011] State 166 Buzzer alarm – Activate 1 Bit C R W T - [1.003] Enable 167 Buzzer alarm – Activate status 1 Bit C R - T - [1.011] State 168 Keypad lock – Activate 1 Bit C R W T - [1.003] Enable 169 Keypad lock – Activate status 1 Bit C R - T - [1.011] State
4. Reference standards
EN 50491-2 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS). Part 2: Environmental conditions
EN 50491-3 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) Part 3: Electrical safety requirements
EN 50491-5-1 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) Part 5-1: EMC requirements, conditions and test set-up
EN 50491-5-2 General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) Part 5-2: EMC requirements for HBES/BACS used in residential, commercial and light industry environment