15
T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM Pattern Play - In Stock Acoustical/Decorative Panels I T COLL O C EC IL DETA S ON SIZE: Acoustical: WPVEP319 and WPVEP320: 11 ¾" x 47 ¾"; WPVEP321: 11 ¾" x 46 ¾"; WPVEP322: 23 ½" x 23 ½"; Decorative: WPVEP324: 17.14" x 45.15"; WPVEP325: 16.05" x 41.69"; WPVEP326: 24" x 24"; WPVEP323: 14" x 56"; WPVEP327: 23 ½" x 23 ½" THICKNESS: Acoustical: WPVEP319 and WPVEP320: 52.3mm; WPVEP321: 52.1mm; WPVEP322: 51.5mm; Decorative: WPVEP323: 10.6mm (including backing); WPVEP324 - WPVEP327: 7mm (including backing) CONSTRUCTION: Acoustical: WPVEP319 and WPVEP320: 4 layers - Wood: 3.3mm - 4.8mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; WPVEP321: 4 layers - Wood: 4.6mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; WPVEP322: 4 layers - Wood: 4mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; Decorative: WPVEP323: 6mm Russian Birch; WPVEP324 - WPVEP327: 3mm Fibrex FINISH: 10% sheen UV Varnish SPECIES: WPVEP319, WPVEP321, WPVEP322, WPVEP323, WPVEP324, WPVEP326 and WPVEP327: White Oak veneer; WPVEP320 and WPVEP325: Walnut veneer INSTALLATION: Acoustical: Glue and nail over plywood or drywall only; Decorative: Interlocking, Glue and Finishing Nails HEALTH AND WELLNESS: Antimicrobial protective coating Corner moldings available Movable partitions - acoustical or decorative panels can be customized and fabricated to your specifications, contact [email protected] No VOC emissions Class A Fire Rated (upon request), minimums may apply When Fire Rated, the antimicrobial protective coating will not be put on Acoustical: Sound Absorbing, NRC = 0.66 Can contribute to LEED ® In stock products are subject to availability Please note that variations in color and texture may occur due to the nature of the material SPECIFICATIONS View collection web page for the complete offering including additional product options, corresponding Spec ID# and updates. Formation - White Oak WPVEP319 Cuboid - Walnut WPVEP325 Formation - Walnut WPVEP320 Contour - White Oak WPVEP326 Ziggurat - White Oak WPVEP321 Linear - White Oak WPVEP322 Ziggurat - White Oak Acoustical: WPVEP321 Decorative: WPVEP323 Cuboid - White Oak WPVEP324 Linear - White Oak Acoustical: WPVEP322 Decorative: WPVEP327 The sense of hand is apparent in each of the expressive patterns from our newest wood panel offering, Pattern Play Acoustical/Decorative Panels: Cuboid, Contour, Linear, Ziggurat and Formation. All are made from natural walnut and white oak wood veneers with an MDF core that have an antimicrobial protective coating and share an interlocking installation method with corner trims available. Linear, Ziggurat and Formation are enhanced with a four layer construction to provide a dimensional and distinctly designed acoustical panel. Ziggurat and Linear are available with the acoustical backing option or as a decorative veneer while Cuboid and Contour are solely decorative panels. These playful patterns point to the nuances for today's spaces aesthetically, acoustically and with a focus on wellness. Acoustical Backing: Decorative Veneer: Acoustical Backing or Decorative Veneer:

Pattern Play...T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COMPattern Play - In Stock Acoustical/Decorative Panels TI COLLCO EC DETAILS O N SIZE

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM

    Pattern Play - In StockAcoustical/Decorative Panels

    IT

    CO

    LL

    OC

    EC

    ILD

    ET

    AS

    ON

    SIZE: Acoustical: WPVEP319 and WPVEP320: 11 ¾" x 47 ¾"; WPVEP321: 11 ¾" x 46 ¾"; WPVEP322: 23 ½" x 23 ½"; Decorative: WPVEP324: 17.14" x 45.15"; WPVEP325: 16.05" x 41.69"; WPVEP326: 24" x 24"; WPVEP323: 14" x 56"; WPVEP327: 23 ½" x 23 ½"THICKNESS: Acoustical: WPVEP319 and WPVEP320: 52.3mm; WPVEP321: 52.1mm; WPVEP322: 51.5mm; Decorative: WPVEP323: 10.6mm (including backing); WPVEP324 - WPVEP327: 7mm (including backing)CONSTRUCTION: Acoustical: WPVEP319 and WPVEP320: 4 layers - Wood: 3.3mm - 4.8mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; WPVEP321: 4 layers - Wood: 4.6mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; WPVEP322: 4 layers - Wood: 4mm, Felt: 6.4mm, Honeycomb cardboard: 38.1mm, MDF: 3mm; Decorative: WPVEP323: 6mm Russian Birch; WPVEP324 - WPVEP327: 3mm FibrexFINISH: 10% sheen UV VarnishSPECIES: WPVEP319, WPVEP321, WPVEP322, WPVEP323, WPVEP324, WPVEP326 and WPVEP327: White Oak veneer; WPVEP320 and WPVEP325: Walnut veneerINSTALLATION: Acoustical: Glue and nail over plywood or drywall only; Decorative: Interlocking, Glue and Finishing NailsHEALTH AND WELLNESS: Antimicrobial protective coating• Corner moldings available• Movable partitions - acoustical or decorative panels can be customized and fabricated to your specifications, contact [email protected]• No VOC emissions• Class A Fire Rated (upon request), minimums may apply• When Fire Rated, the antimicrobial protective coating will not be put on• Acoustical: Sound Absorbing, NRC = 0.66• Can contribute to LEED®

    • In stock products are subject to availability• Please note that variations in color and texture may occur due to the nature of the material

    SPECIFICATIONS

    View collection web page for the complete offering including additional product options, corresponding Spec ID# and updates.

    Formation - White OakWPVEP319

    Cuboid - WalnutWPVEP325

    Formation - WalnutWPVEP320

    Contour - White OakWPVEP326

    Ziggurat - White OakWPVEP321

    Linear - White OakWPVEP322

    Ziggurat - White OakAcoustical: WPVEP321Decorative: WPVEP323

    Cuboid - White OakWPVEP324

    Linear - White OakAcoustical: WPVEP322Decorative: WPVEP327

    The sense of hand is apparent in each of the expressive patterns from our newest wood panel offering, Pattern Play Acoustical/Decorative Panels: Cuboid, Contour, Linear, Ziggurat and Formation. All are made from natural walnut and white oak wood veneers with an MDF core that have an antimicrobial protective coating and share an interlocking installation method with corner trims available. Linear, Ziggurat and Formation are enhanced with a four layer construction to provide a dimensional and distinctly designed acoustical panel. Ziggurat and Linear are available with the acoustical backing option or as a decorative veneer while Cuboid and Contour are solely decorative panels. These playful patterns point to the nuances for today's spaces aesthetically, acoustically and with a focus on wellness.

    Acoustical Backing:

    Decorative Veneer:

    Acoustical Backing or Decorative Veneer:

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    SINSTALLATION METHODWPVEP326

    ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.

    PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.

    INSTALLATION INSTRUCTIONSTOOLS:

    • Vertical adhesive through ASI• Spec ID# FLDTC025

    • Caulking gun• Electric mitre saw• Tablesaw

    • Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder

    STEP 1:If you are using moldings, mark required space around the perimeter of installation area.

    STEP 2:Apply a line of vertical adhesive through ASI, Spec ID# FLDTC025 in the form of a rectangle (1/2" [1.3 cm] from edges) and an X inside the rectangle.

    STEP 4: Nail panel in place with #23 gauge finish nails on the exposed backing. NEVER NAIL DIRECTLY ON FACE OF WALL PANEL.

    •STEP 5: Installation of subsequent panels

    •Repeat Step 2

    •Align panel B against panel ARepeat Step 4

    MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.

    First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    STEP 3:Position first panel at lower left of wall. Make sure the exposed backing are facing up and right. If using moldings, position in area designated in step 1.

    x = #23

    A B

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    S

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    INSTALLATION METHOD CONT.WPVEP326

    STEP 6: End a rowCut any excess of the wall panel to be flush with the edge of the wall.

    STEP 7: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.

    STEP 8: Insert molding in previously designated area if required.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    SINSTALLATION METHODWPVEP323

    ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.

    PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.

    INSTALLATION INSTRUCTIONS

    TOOLS:

    • Vertical adhesive through ASI• Spec ID# FLDTC025

    • Caulking gun• Electric mitre saw• Tablesaw

    • Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder

    STEP 1:If you are using moldings, mark required space around the perimeter of installation area.

    STEP 2:A On back of panel, apply a line of vertical adhesive 1/2" (1.3cm) from all edges and forming an X in the center.

    STEP 4: Nail panel in place with #23 gauge finish nails on the exposed backing. NEVER NAIL DIRECTLY ON FACE OF WALL PANEL.

    •STEP 5: Installation of subsequent panels

    •Repeat Step 2

    •Align panel B against panel ARepeat Step 4

    MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.

    First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    STEP 3:Position first panel at lower left of wall. Make sure the exposed backing are facing up and right. If using moldings, position in area designated in step 1.

    A

    x

    xx

    xxxxx

    x = #23

    xx x x

    x x x

    Panel BPanel A

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    S

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    INSTALLATION METHOD CONT.WPVEP323

    STEP 6: End a rowCut any excess of the wall panel to be flush with the edge of the wall.

    STEP 7: Start a new rowUse remaining piece from the previous row making sure the pattern aligns.

    STEP 8: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.

    STEP 9: Insert molding in previously designated area if required.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    SINSTALLATION METHODWPVEP327

    ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.

    PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.

    INSTALLATION INSTRUCTIONS

    TOOLS:

    • Vertical adhesive through ASI• Spec ID# FLDTC025

    • Caulking gun• Electric mitre saw• Tablesaw

    • Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder

    STEP 1:If you are using moldings, mark required space around the perimeter of installation area.

    STEP 2:On back of panel, apply a line of vertical adhesive 1/2" (1.3cm) from all edges and forming an X in the center.

    STEP 4: Nail panel in place with #23 gauge finish nails on the exposed backing. NEVER NAIL DIRECTLY ON FACE OF WALL PANEL.

    STEP 5: Installation of subsequent panels• Repeat Step 2• Align panel B against panel A• Repeat nailing procedure

    MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.

    First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    STEP 3:Position first panel at lower left of wall. If using moldings, position in area designated in Step 1.

    x = #23

    x x x x

    xx

    x

    xx

    xx x x x

    A B

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    S

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    INSTALLATION METHOD CONT.WPVEP327

    STEP 6: End a rowCut any excess of the wall panel to be flush with the edge of the wall.

    STEP 7: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.

    STEP 8: Insert molding in previously designated area if required.

    SUGGESTED INSTALL:

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    SINSTALLATION METHODWPVEP324 and WPVEP325

    ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.

    PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.

    INSTALLATION INSTRUCTIONS

    TOOLS:

    • Vertical adhesive through ASI• Spec ID# FLDTC025

    • Caulking gun• Electric mitre saw• Tablesaw

    • Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder

    STEP 1:If you are using moldings, mark required space around the perimeter of installation area.

    STEP 2:Cut the excess wood to be straight with the backing.

    MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.

    First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    STEP 3:A. Position first panel at lower left of wall. If

    using moldings, position in area designated inStep 1.

    B. Apply glue on exposed backing.

    A

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    SINSTALLATION METHOD CONT.WPVEP324 and WPVEP325

    STEP 5:Nail panel in place with #23 gauge nails on the exposed backing and on the hollow part of the wood at the bottom.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    STEP 7:Cut any excess of wall panel flush with edge of wall.

    STEP 8: Start a new rowUse remaining piece from previous row making sure the pattern aligns.

    STEP 9: Last rowCut panels of last row lengthwise to fit available space. If required, allow enough space for the molding.

    STEP 10:Insert molding in previously designated area if required.

    x x x x

    x

    xxxx

    STEP 4:Position first panel at lower left of wall. If using moldings, position in area designated in Step 1.

    STEP 6: Installation of subsequent panels• Cut the excess of the wood at the bottom of the

    wall panel• Repeat step 3• Insert panel B into panel A• Repeat step 5

    PANEL A PANEL B

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    SINSTALLATION METHODWPVEP319 and WPVEP320

    ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to the installation instructions and are maintained in an environment where ambient humidity ranges between 35% and 55%: before, during and after installation. LEAVE THE BOX IN THE ROOM IT IS TO BE INSTALLED FLAT ON THE FLOOR IN ITS ORIGINAL WRAPPING UNTIL INSTALLATION.

    PRECAUTIONS: Always wear work gloves and safety glasses when installing the product.

    INSTALLATION INSTRUCTIONS

    TOOLS:

    • Vertical adhesive through ASI• Spec ID# FLDTC025

    • Caulking gun• Electric mitre saw• Tablesaw

    • Level• Measuring tape• Cutter• Pneumatic finish hammer (#23 gauge finish nail)• Stepladder

    STEP 1:If you are using moldings, mark required space around the perimeter of installation area.

    STEP 2:Cut a minimum of 6" (15cm) from male side of panel to form your starting panel.

    MAKE SURE YOUR KNIVES AND SAW-BLADES ARE IN PRIME CONDITION.

    First, check the wall(s) is level from floor to ceiling and edge-to-edge. If not, adjust accordingly.

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    STEP 3:A. Position first panel at lower left of wall. If

    using moldings, position in area designated inStep 1.

    A

    min 6” (15 cm)

    STEP 4:Position first panel at lower left of wall.

    STEP 5: Nail panel in place with #18 gauge finish.

    A. Nail at the top and right at an angle on theback layer of MDF.

    B. Nail directly into the felt between the last 2bottom rows. The nail will go through theunder layers to the MDF.

    x x x

    x = #18

  • T: 212.206.1730 | F: 212.206.1736 | [email protected] | ARCHSYSTEMS.COM

    CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    S

    The wall panel needs to be glued and nailed for a successful install and to prevent future warping. Failure to comply with the installation instructions shall void the application of the warranty. This is a glue and nail installation. Do not install over material other than drywall and plywood.

    INSTALLATION METHOD CONT.WPVEP319 and WPVEP320

    STEP 6: Installation of subsequent panels• Repeat Step 3• Apply glue to the back of the female wood slats. Avoid

    overflow that could spread on the felt.• Insert panel B into panel A

    Repeat Step 5

    NOTE: If wood pieces detaches from a wall panel, reposition using vertical adhesive through ASI, Spec ID# FLDTC025.

    Panel A Panel B

    STEP 7: End a rowCut any excess of wall panel flush with edge of wall.

    STEP 8: Start a new rowUse remaining piece from previous row or repeat Step 2. Repeat Steps 3, 4, and 5.

    STEP 9: Last rowCut panels of last row lengthwise to fit available space.

    STEP 10: Insert molding in previously designated area if required.

  • CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    SMAINTENANCEClean-up recommendations: a regular dusting with a soft cloth or a feather duster.

    WARRANTYASI | Architectural Systems, Inc. guarantees Pattern Play - Acoustical/Decorative Panels against manufacturing defects. If, upon opening a box, a panel is defective or fails to meet Architectural Systems, Inc. quality standards, the consumer may return the panel to ASI | Architectural Systems, Inc. for replacement.

    This product is flammable and its use near an important heating source (such as a gas fireplace, solid burning appliances, slow burning stove) is not recommended. Please check the latest construction regulations or the nearest fire department in your locality. In most cases, the use of decorative wood walls is forbidden near these heating sources.

    A panel with glue applied to its back or an installed panel (nailed) is deemed accepted and cannot be claimed under warranty. An unglued lamination may be glued back together using vertical adhesive through ASI, Spec ID# FLDTC025. Given the nature of wood, it is possible that Interwoven Eco-Panels may exhibit color variations from one panel to the next or from one production lot to the next. We recommend that you arrange the panels on the wall based on your personal color preferences. Such variations may not be claimed under warranty.

    Before installing a panel, check the fit prior to spreading glue on the panel. If a panel fails to interlock properly, attempt to position it on a panel in another row. If the Interwoven Eco-Panel once again, fails to interlock properly, please return it to Architectural Systems, Inc. for replacement.

    ASI | Architectural Systems, Inc. guarantees the conformity of its products when they are installed according to Interwoven Eco-Panels installation guidelines and are maintained in an environment where ambient humidity ranges between 37% and 45%. Failure to comply with installation and maintenance instructions and with recognized trade techniques could void the application of these warranties.

    For questions regarding the interpretation of the warranty, contact ASI | Architectural Systems, [email protected]

    T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM

  • CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    S

    T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM

    TECHNICAL DATA

    WPVEP327

    Wood veneer with an MDF

    core

    23.5” / 59.69 cm

    23.5” / 59.69 cm

    4 panels / box – 15.3 ft2 / box

    Fibrex 3 mm

    Wood veneer

    with an MDF core

    4 mm

    45.15” / 114.68 cm

    17.14” / 43.54 cm

    4 panels / box – 21.48 ft2 / box

    Russian birch 3 mm

    4.5” / 11.4 cm

    WPVEP324

  • CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    S

    T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM

    TECHNICAL DATA CONT.

    Wood veneer with an MDF core

    4.6 mm

    Russian Birch6 mm

    56” / 142.24 cm

    14” / 35.56 cm

    4 panels / box – 21.7 ft2 / box

    WPVEP323

    Wood veneer with an MDF core

    4 mmFibrex 3 mm

    41.69” / 105.8 cm

    16.05” / 40.7 cm

    4.5” / 11.4 cm

    4 panels / box – 18.6 ft2 / box

    WPVEP325

  • CO

    LL

    EC

    TIO

    N D

    ET

    AIL

    S

    T: 212.206.1730 | F: 212.402.1760 | [email protected] | ARCHSYSTEMS.COM

    TECHNICAL DATA CONT.

    WPVEP326

    Wood veneer with an MDF core

    4 mm

    24” / 60.96 cm

    Piece 1 Piece 2 Piece 3

    Piece 4 Piece 5 Piece 6

    24” / 60.96 cm

    6 panels / box – 24 ft2 / box

    Fibrex 3 mm

    installationmaintenancewarrantytechnical