Calculation of Fixing Force
EXAMPLE:Clamp Plate model MGA010-M(Movable side) 1. Magnet cores that the adaptor plate contacts with its entire area = 4 pcs
2. Magnet cores that the adaptor plate contacts with 1/2 of its area = 8 pcs
3. Magnet cores that the adaptor plate contacts with 1/4 of its area = 4 pcs
4. Total magnet cores that the adaptor plate contacts
= 4 pcs + 8 pcs X 1/2 + 4 pcsX 1/4 = 9 pcs
5. Fixing force per magnet core
= 7.35 kN/pcs (refer to the table on the right)
6. Rated fixing force = 7.35 kN/pcs X 9 pcs = 66.15 kN
REMARK (1) If there is a hole or notch at the bottom of adaptor plate, reduce the
respective area from the total contact area (number of magnet core). (2) The actual fixing force may be lower than the rated capacity
according to the conditions of adaptor plate. Refer to Decline of
Fixing Force at below. Prior to the actual operation, be sure to
read the operation manual for further details
Movable Platen Clamp Plate model MGA010-M
Magnet Core 70 x 70 mm
Adaptor Plate
70 x 70 mm 7.35 kN
75 x 75 mm 7.84 kN Fixing Force per Magnet Core(Aprox.)
115 x 115 mm 15.68 kN
Calculation of Rated Fixing Force
The fixing force of MAG clamp (the adhering force of magnet clamp) varies according to the area size (number of magnet core) where
the adaptor plate and clamp plate contact. When loading a small mold of which adaptor plate does not contact all the magnet cores,
you are requested to work out the rated fixing force by referring to below example.
Decline of Fixing Force
According to the conditions of adaptor plate for the mold, the actual force may become lower than the rating. Before using MAG
clamp, be certain to calculate and acknowledge the decline of fixing force according to the below tables and charts. And be sure to
use in the strict condition that the actual fixing force is larger than the mold opening force of injection machine.
(Actual Fixing Force)=(Rated Fixing Force - Reduced Force)≧(Mold Opening Force of Injection Machine)
If the actual fixing force is calculated as short, replace the adaptor plate with the larger one to enlarge the contact area.
Material Fixing Force SS400 S55C S45C-H
100% (Rated)
S45C 95% SK3 SUJ 85%
SUS430 FCD250 FCD600
80%
SKH51 SKD11 70%
As shown above, type of material of adaptor plate significantly affects the fixing force.
Surface Roughness Fixing Force
▽▽▽ (Rz1.6~3.8)
100% (Rated)
▽▽ (Rz7.5~15.5)
Aprox. 100%
▽ (Rz85~150)
Aprox. 90%
As shown above, surface roughness of adaptor plate largely decrease the fixing force.
Surface of Adaptor Plate Material of Adaptor Plate Distance between two plates
A dent or deformation of the adaptor plate creates a distance to the clamp plate, which will decrease the fixing capacity significantly.
Fixi
ng F
orce
(%)
100
Distance (mm)
0.5
50
01.00
Temperature of Adaptor Plate
If the temperature of adaptor plate becomes too high, the fixing force significantly decreases. Be sure to use by keeping the temperature below 80 ℃. (For details, refer to instruction manual)
Fixi
ng F
orce
(%)
100
Surface Temperature of Clamp Plate (℃)
50
50
01500 100
Standard Type
Heat Proof Type
― 2 ―
Interlock
● During automatic operation
If the mold is displaced or floated from the
clamp plate, the molding machine is sharply
stopped by Displacement Detection System.
● When changing a mold
All below conditions ①~④ should be ready before start operating MAG clamp.
① MAG Clamp:Mold Change ON ② Molding Machine:Set-up (or manual) mode ON
③ Molding Machine:Nozzle Retracted ④ Molding Machine:Mold Close Complete
Conditions ②~④ for Molding machine can be checked by LED on the operation panel.
Following interlock functions are integrated in the electric control circuit of PASCAL MAG Clamp for secured mold change works.
Signals for Interlock
MAG Clamp Molding Machine Name of Signal Explanation
Mold Change [ON] During mold change works (when key switch is at Mold Change [ON]), automatic or semi-automatic operation can not be done at IMM.
Mold Open Possible Mold Close Possible
By key switch’s position and MAG clamp’s condition, opening and closing of mold at IMM are restricted to avoid fall of mold. <At MOLD CHANGE [OFF]> ●Mold Open and Mold Close both possible at below condition * Fixed Platen [MAG ON] / Movable platen [MAG ON] ●Emergency stop of IMM at below conditions * Fixed Platen [MAG OFF] / Movable platen [MAG OFF] * Fixed Platen [MAG OFF] / Movable platen [MAG ON] * Fixed Platen [MAG ON] / Movable platen [MAG OFF] <At MOLD CHANGE [ON]> ●Only Mold Open possible at below condition * Fixed Platen [MAG ON] / Movable platen [MAG ON] ●Mold Open and Mold Close both possible at below condition * Fixed Platen [MAG OFF] / Movable platen [MAG OFF] * Fixed Platen [MAG OFF] / Movable platen [MAG ON] * Fixed Platen [MAG ON] / Movable platen [MAG OFF]
Emergency Stop (Normal ON) (Circuit for Emergency stop of molding machine)
Becomes effective if the mold is displaced or floated from the clamp plate during automatic operation of molding machine (Displacement Detection System).
Emergency Stop (Normal OFF)(Display Circuit for Emergency stop of molding machine)
Becomes effective when MAG clamp is at abnormal condition.
Pressure Build Up Signal to close the mold at IMM (applicable when required at IMM side)
Mold Set Mode Signal telling that IMM is on Set-up mode. MAG clamp can be operated only when this signal is effective.
Nozzle Retracted Signal telling that nozzle (injection unit) is at the retracted end. MAG clamp can be operated only when this signal is effective.
Mold Close Complete Signal telling that IMM completed a mold close. MAG clamp can be operated only when this signal is effective.
Mold Open Signal telling that IMM is at mold open. In this condition, MAG clamp can not be operated.
(No signal is transmitted to IMM)
MAG Clamp Operation Impossible
Time restriction of ON/OFF consecutive switching. (protection against heat elevation)
Caution in Use
― 3 ―
!
● MAG Clamp generates a powerful magnetism. The person who is wearing a cardiac pacemaker is strictly prohibited to
approach. Projecting height of magnet line above the clamp plate towards forward (to mold side) is just around 20 mm.
However, be sure not to bring mobile phone, magnetic card or compact disc, etc. that are susceptible to magnetism close to the
clamp plate to avoid a damage.
● Be sure to carry out a mold change work always under the condition that the mold is lifted with crane.
● Do not bring any magnetic substance such as ferrous metal close to the adherence surface when MAG clamp is magnetized (at
clamping). Due to the power of magnet, it may be adhered to the clamp surface to cause injury to a finger or hand.
● The fixing force of MAG clamp (the adhering force of magnet clamp) varies according to the area size (number of magnet core)
where the adaptor plate and clamp plate contact. And the actual fixing force may be lower than the rated capacity according to
the conditions of adaptor plate. Refer to Decline of Fixing Force separately shown for the details.
● Do not use a mold that is dented or deformed. If there is a gap between the adaptor plate and clamp plate, fixing force will
decrease.
● Be sure to use MAG clamp by keeping the adherence surfaces of adaptor plate and clamp plate always clean. Water or oil
would not cause a decrease of fixing capacity. However they will attract dusts or foreign substances, which may create a gap
between the adaptor plate and clamp plate.
● Proof temperature of MAG clamp is up to 80℃. Do not use a mold of which contact surface becomes higher than that. If the
mold becomes heated, cool it down immediately. Note that once the surface temperature of clamp plate exceeds120℃, the
fixing force will no longer be assured even at the normal temperature.
● Be sure to use an adaptor plate of which thickness is more than 25 mm. As the projecting height of magnet line is 20 mm, if
the thickness of adaptor plate is less than 25 mm, the fixing force may become decreased.
● In the case of a mold which pushes out the molded parts with ejector pin, be sure to confirm that the length and hole position,
etc. of ejector pin are correct. If wrong, the mold may be pushed out by ejector pin to fall.
MAG clamp duly holds the mold even when the mold is declined. Se the mold with care so that the ejector pin and pin hole
position are well-aligned. For the confirmation of alignment, lift the mold and push and pull the ejector pin to check the smooth
action.
Movable Platen of Molding Machine
Clamp Plate
Ejector Pin Hole
Adaptor Plate
Ejector Pin Clamp Plate
Ejection Force
Fall
Misalignment of Pin Hole
Mold
(REMARK 2) 290[TIE-BAR DISTANCE-30]
(REMARK 2) 290
[TIE-BAR DISTANCE-30]
120
200
480
(REMARK 2) 320
(REMARK 2) 320
(REMARK 2) 460
(REMARK 2) 460
480
58.3
300
50
200
120
202
362
60
4 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
2 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
B-BMoving Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 2) 290
[TIE-BAR DISTANCE-30]
(REMARK 2) 290[TIE-BAR DISTANCE-30]
120
100 H7Locate Ring
(REMARK 2) 320
(REMARK 2) 460
480
(REMARK 2) 320
(REMARK 2) 460
480
400
75
200
424
75
325
58.3
60
175
175
C
C
6 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Stationary Platen
Clamp Plate
Connector Box
A-AStationary Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK4)30
20
50 50
B
B
A
A
D
100
100
90
1550
130
25
C-C (1 : 4)Details of locating
Locate Ring 1
Clamp PlateStationary Side
Stationary Platen
Locate Ring 2
90°
R0.8(1.7)
0.5
D (5 : 1)※OptionCenter Edge
STANDARD
MGA005 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The hole diameter is 32 mm. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1671.slddrw3MGAA16710MGA005030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:6
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 8 8115 mm square - -
59kN 59kN74kg 71kg
M16x55 4 6M12x50 2 -
Applied Mold Clamping Force 500~600kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 8 8115 mm square - -
59kN 59kN74kg 71kg
M16x55 4 6M12x50 2 -
Applied Mold Clamping Force 500~600kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 330[TIE-BAR DISTANCE-30]
(REMARK 2) 330
[TIE-BAR DISTANCE-30]
120
200
(REMARK 2) 530
(REMARK 2) 530
58.3
(REMARK 2) 360
(REMARK 2) 360
120
450
250
450
250
50
202
202
362
362
60
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
2 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
B-BMoving Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 2) 330
[TIE-BAR DISTANCE-30]
(REMARK 2) 330[TIE-BAR DISTANCE-30]
120
(REMARK 2) 530
(REMARK 2) 530
58.3
100 H7Locate Ring
(REMARK 2) 360
(REMARK 2) 360
250
450
250
450
310
310
120
120
60
C
C
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Stationary Platen
Clamp Plate
2 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
Connector Box
A-AStationary Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 4)50 5020
30
B
B
A
A
D
90
100
15
130
50
25
100
C-C (1 : 4)Details of locating
Clamp PlateStationary Side
Locate Ring 1 Stationary Platen
Locate Ring 2
0.5
R0.8(1.7)
90°
D (5 : 1)※OptionCenter Edge
STANDARD
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The hole diameter is 35 mm. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
CLASS DEFINITION
① ② ③ ④ ⑤MGA008 -
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1681.slddrw3MGAA16810MGA008030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:8
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 12 12115 mm square - -
88kN 88kN91kg 89kg
M16x55 8 8M12x50 2 2
Applied Mold Clamping Force 750~850kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 12 12115 mm square - -
88kN 88kN91kg 89kg
M16x55 8 8M12x50 2 2
Applied Mold Clamping Force 750~850kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 380[TIE-BAR DISTANCE-30]
(REMARK 2) 380
[TIE-BAR DISTANCE-30]
120
200
(REMARK 2) 610
(REMARK 2) 610
58.3
(REMARK 2) 410
(REMARK 2) 410
250
362
450
120
250
362
450
50
60
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
2 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
B-BMoving Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 2) 380
[TIE-BAR DISTANCE-30]
(REMARK 2) 380[TIE-BAR DISTANCE-30]
120
(REMARK 2) 610
(REMARK 2) 610
58.3
100 H7Locate Ring
(REMARK 2) 410
(REMARK 2) 410
250
450
250
310
450
310
120
120
60
C
C
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Stationary Platen
Clamp Plate
2 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
Connector Box
A-AStationary Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 4)
30
20
50 50
B
B
A
A
D
100
90
100
15
130
50
25
C-C (1 : 4)Details of locating
Clamp PlateStationary Side
Locate Ring 1 Stationary Platen
Locate Ring 2
90°
(1.7)
0.5
R0.8
D (5 : 1)※OptionCenter Edge
STANDARD
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The hole diameter is 35 mm. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
CLASS DEFINITION
① ② ③ ④ ⑤MGA010 -
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1691.slddrw3MGAA16910MGA010030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:8
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 16 12115 mm square - -
118kN 88kN122kg 120kg
M16x55 8 8M12x50 2 2
Applied Mold Clamping Force 1000~1250kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 16 12115 mm square - -
118kN 88kN122kg 120kg
M16x55 8 8M12x50 2 2
Applied Mold Clamping Force 1000~1250kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 480[TIE-BAR DISTANCE-30]
(REMARK 2) 480
[TIE-BAR DISTANCE-30]
120
200
(REMARK 2) 750
(REMARK 2) 750
58.3
(REMARK 2) 510
(REMARK 2) 510
120
250
650
120
250
650
50
522
522
362
362
60
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
4 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
B-BMoving Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 2) 480
[TIE-BAR DISTANCE-30]
(REMARK 2) 480[TIE-BAR DISTANCE-30]
120
(REMARK 2) 750
(REMARK 2) 750
58.3
100 H7Locate Ring
(REMARK 2) 510
(REMARK 2) 510
250
650
250
650
470
470
310
310
120
120
60
C
C
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Stationary Platen
Clamp Plate
4 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
Connector Box
A-AStationary Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 4)
30
20 50 50
B
B
A
A
D
90
100
15
130
50
100
25
C-C (1 : 4)Details of locating
Clamp PlateStationary Side
Locate Ring 1
Locate Ring 2
Stationary Platen
0.5
R0.8(1.7)
90°
D (5 : 1)※OptionCenter Edge
STANDARD
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The hole diameter is 35 mm. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
CLASS DEFINITION
① ② ③ ④ ⑤MGA015 -
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1701.slddrw3MGAA17010MGA015030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:10
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 32 28115 mm square - -
235kN 206kN189kg 187kg
M16x55 8 8M12x50 4 4
Applied Mold Clamping Force 1300~2200kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 32 28115 mm square - -
235kN 206kN189kg 187kg
M16x55 8 8M12x50 4 4
Applied Mold Clamping Force 1300~2200kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 530[TIE-BAR DISTANCE-30]
(REMARK 2) 530
[TIE-BAR DISTANCE-30]
120
200
(REMARK 2) 820
(REMARK 2) 820
58.3
(REMARK 2) 560
(REMARK 2) 560
610
250
320
610
650
250
650
50
60
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
2 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
B-BMoving Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
(REMARK 2) 530[TIE-BAR DISTANCE-30]
120
(REMARK 2) 82058.3
(REMARK 2) 560
100 H7Locate Ring
470
120
470
650
250
(REMARK 2) 560
(REMARK 2) 820
(REMARK 2) 530
[TIE-BAR DISTANCE-30]
470
250
650
60
120
C
C
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Stationary Platen
Clamp Plate
4 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
Connector Box
A-AStationary Side
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M16)
A
A
D
(REMARK4)
30
20
50 50
B
B
100
90
25
50 15
100
130
C-C (1 : 4)Details of locating
Locate Ring 1
Locate Ring 2Clamp PlateStationary Side
Stationary Platen
0.5
90°
(1.7)
R0.8
D (5 : 1)※OptionCenter Edge
STANDARD
MGA025 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701. The diameter of center hole is 60 mm. The ones of other holes are 35 mm. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1711.slddrw3MGAA17110MGA025030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:10
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 32 32115 mm square 1 -
251kN 235kN225kg 226kg
M16x55 8 8M12x50 2 4
Applied Mold Clamping Force 2300~2800kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - -70 mm square 32 32115 mm square 1 -
251kN 235kN225kg 226kg
M16x55 8 8M12x50 2 4
Applied Mold Clamping Force 2300~2800kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 1030
(REMARK 2) 700[TIE-BAR DISTANCE-30]
(REMARK 2) 700
[TIE-BAR DISTANCE-30]
120
(REMARK 2) 730
(REMARK 2) 1030
58.3
(REMARK 2) 730
601
250
200
350
850
350
576
650
752
180
71
150 H7Locate Ring
C
C
Clamp Plate
Stationary Platen
4 x M12 Depth 21Bolt : M12 x 50Square Washer : M12
8 x M20 Depth 35Bolt : M20 x 60Square Washer : M20
Connector Box
Magnet Core
A-AStationary Side
Displacement Detection Magnet Core
(REMARK4)
※OptionMold Fall Protection Hook(Eye Bolt : M20)
(REMARK 2) 700[TIE-BAR DISTANCE-30]
(REMARK 2) 1030
(REMARK 2) 700
[TIE-BAR DISTANCE-30]
120
58.3
(REMARK 2) 730
(REMARK 2) 1030
(REMARK 2) 730
300
55.1
250
400
650
500
850
703
71
250
400
500
650
850
703
Mold Fall Protection Block
Clamp Plate
Moving Platen
Connector Box
4 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Magnet Core
B-BMoving Side
Displacement Detection Magnet Core
16 x M20 Depth 35Bolt : M20 x 60Square Washer : M20
※OptionMold Fall Protection Hook(Eye Bolt : M20)
30
25.1 50 50
B
B
A
A
D
150
140
150
25
50 25
15
180
250
C-C (1 : 6)Details of locating
Locate Ring 1
Clamp PlateStationary Side Locate Ring of Stationary Platen
Stationary Platen
Locate Ring 2
90°
(1.7)
0.5
R0.8
D (5 : 1)※OptionCenter Edge
STANDARD
MGA035 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of center hole is 60 mm. The ones of inner 12 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1721.slddrw3MGAA17210MGA035030062003/11/01XXX9A-034-3
NAME
S-30300-002
1:12
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 4270 mm square 40 -115 mm square 1 -
310kN 329kN356kg 360kg
M20x60 16 8M16x55 4 -M12x50 - 4
Applied Mold Clamping Force 3500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 4270 mm square 40 -115 mm square 1 -
310kN 329kN356kg 360kg
M20x60 16 8M16x55 4 -M12x50 - 4
Applied Mold Clamping Force 3500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 780[TIE-BAR DISTANCE-30]
(REMARK 2) 1200
(REMARK 2) 810
(REMARK 2) 810
(REMARK 2) 1200
120
58.3
150 H7Locate Ring
350
576
752
850
500
(REMARK 2) 780
[TIE-BAR DISTANCE-30]
71
350
400
850
500
752
576
C
C
Clamp Plate
Stationary Platen
Connector Box
A-AStationary Side
12 x M20 Depth 35Bolt : M20 x 60Square Washer : M20
Magnet Core
4 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M20)
(REMARK 2) 1200
(REMARK 2) 780
[TIE-BAR DISTANCE-30]
120
(REMARK 2) 810
(REMARK 2) 780[TIE-BAR DISTANCE-30]
(REMARK 2) 810
(REMARK 2) 1200
300
55.1
58.3
250
320
500
650
850
816
71
250
320
500
650
850
816
Mold Fall Protection Block
Clamp Plate
Moving Platen
Connector Box
B-BMoving Side
16 x M20 Depth 35Bolt : M20 x 60Square Washer : M20
Magnet Core
4 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M20)
30
524925.1
B
B
A
A
D
(REMARK4)
150
140
150
180
15
52
25
25
250
C-C (1 : 6)Details of locating
Locate Ring 1
Clamp PlateStationary Side
Stationary Platen
Locate Ring 2
Locate Ring of Stationary Platen
90°
(1.7)
0.5
R0.8
E (5 : 1)※OptionCenter Edge
STANDARD
MGA045 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of center hole is 60 mm. The ones of inner 12 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1731.slddrw3MGAA17310MGA045030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:14
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 5270 mm square 52 -115 mm square 1 -
398kN 408kN498kg 506kg
M20x60 16 12M16x55 4 4
Applied Mold Clamping Force 4500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 5270 mm square 52 -115 mm square 1 -
398kN 408kN498kg 506kg
M20x60 16 12M16x55 4 4
Applied Mold Clamping Force 4500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 830[TIE-BAR DISTANCE-30]
300
(REMARK 2) 1230
(REMARK 2) 1230
(REMARK 2) 860
(REMARK 2) 830
[TIE-BAR DISTANCE-30]
(REMARK 2) 860
58.3
120
250
500
350
650
85055.1
71
350
250
500
816
850
650
816
Moving Platen
Clamp Plate
Mold Fall Protection Block
4 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
B-BMoving Side
16 x M20 Depth 35Bolt : M20 x 60Square Washer : M20
Connector BoxMagnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M20)
(REMARK 2) 830[TIE-BAR DISTANCE-30]
(REMARK 2) 1230
(REMARK 2) 1230
58.3
(REMARK 2) 860
150 H7Locate Ring
350
850
500
120
742
(REMARK 2) 830
[TIE-BAR DISTANCE-30]
(REMARK 2) 860
742
850
350
500
400
71
C
C
Stationary Platen
Clamp Plate
Connector Box
A-AStationary Side
4 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
12 x M20 Depth 35Bolt : M20 x 60Square Washer : M20
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M20)
(REMARK4)
4952
30
25.1
B
BA
A
D
180
150
140
150
25
52 25
15
250
C-C (1 : 6)Details of locating
Locate Ring 1
Locate Ring of Stationary PlatenClamp PlateStationary Side
Stationary Platen
Locate Ring 2
90°
(1.7)
0.5
R0.8
D (5 : 1)※OptionCenter Edge
STANDARD
MGA055 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of center hole is 60 mm. The ones of inner 12 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1741.slddrw3MGAA17410MGA055030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:14
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 5670 mm square 56 -115 mm square 1 -
427kN 439kN542kg 538kg
M20x60 16 12M16x55 4 4
Applied Mold Clamping Force 5500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 5670 mm square 56 -115 mm square 1 -
427kN 439kN542kg 538kg
M20x60 16 12M16x55 4 4
Applied Mold Clamping Force 5500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 930[TIE-BAR DISTANCE-30]
120
400
(REMARK 2) 1400
(REMARK 2) 1400
(REMARK 2) 960
(REMARK 2) 930
[TIE-BAR DISTANCE-30]
(REMARK 2) 960
58.3
250
350
250
350
650
1050
650
1050
59.9
933
933
90
Moving Platen
Clamp Plate
Mold Fall Protection Block
4 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
B-BMoving Side
16 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Connector Box
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
120
(REMARK 2) 1400
(REMARK 2) 930
[TIE-BAR DISTANCE-30]
150 H7Locate Ring
(REMARK 2) 1400
58.3
(REMARK 2) 960
(REMARK 2) 960
350
400
850
1050
742
917
500
500
90
(REMARK 2) 930[TIE-BAR DISTANCE-30]
566
742
C
C
Stationary Platen
Clamp Plate
Connector Box
A-AStationary Side
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
8 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Magnet Core
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
30
29.9
5249
B
BA
A
D
(REMARK4)
180
150
140
150
15
52 25
250
25
C-C (1 : 6)Details of locating
Locate Ring 1
Locate Ring of Stationary PlatenClamp PlateStationary Side Stationary Platen
Locate Ring 2
90°
(1.7)
0.5
R0.8
D (5 : 1)※OptionCenter Edge
STANDARD
MGA065 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of center hole is 60 mm. The ones of inner 12 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1751.slddrw3MGAA17510MGA065030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:15
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 6870 mm square 72 -115 mm square 1 -
545kN 533kN678kg 686kg
M24x60 16 8M16x55 4 8
Applied Mold Clamping Force 6500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 6870 mm square 72 -115 mm square 1 -
545kN 533kN678kg 686kg
M24x60 16 8M16x55 4 8
Applied Mold Clamping Force 6500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 1030[TIE-BAR DISTANCE-30]
(REMARK 2) 1030
[TIE-BAR DISTANCE-30]
120
400
(REMARK 2) 1530
(REMARK 2) 1530
58.3
(REMARK 2) 1060
250
320
500
600
850
1047
1250
(REMARK 2) 1060
120
400
59.9
90
320
250
500
850
1250
1047
720
16 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Magnet Core
B-BMoving Side
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
CLASS DEFINITION
① ② ③ ④ ⑤MGA085 -
(REMARK 2) 1030[TIE-BAR DISTANCE-30]
120
(REMARK 2) 1530
(REMARK 2) 1530
(REMARK 2) 1030
[TIE-BAR DISTANCE-30]
58.3
150 H7Locate Ring
350
500
400
750
1050
400
120
742
917
(REMARK 2) 1060
(REMARK 2) 1060
742
917
90
350
650
1050
750
400
C
C
Stationary Platen
Clamp Plate
Connector Box
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
12 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Magnet Core
A-AStationary Side
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
30
29.9 52 49
B
B
A
A
D
(REMARK4)
150
140
150
180
25
52
15
25
250
C-C (1 : 6)Details of locating
Clamp PlateStationary Side Locate Ring of Stationary Platen
Locate Ring 2
Locate Ring 1
Stationary Platen
0.5
(1.7)
90°
R0.8
D (5 : 1)※OptionCenter Edge
STANDARD
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of center hole is 60 mm. The ones of inner 12 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1761.slddrw3MGAA17610MGA085030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:20
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 8870 mm square 84 -115 mm square 1 -
633kN 690kN825kg 839kg
M24x60 16 12M16x55 8 8
Applied Mold Clamping Force 8500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 8870 mm square 84 -115 mm square 1 -
633kN 690kN825kg 839kg
M24x60 16 12M16x55 8 8
Applied Mold Clamping Force 8500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
120
400
(REMARK 2) 1800
(REMARK 2) 1700
58.3
(REMARK 2) 1300
(REMARK 2) 1270[TIE-BAR DISTANCE-30]
570
120
(REMARK 2) 1170
[TIE-BAR DISTANCE-30]
(REMARK 2) 1200
320
350
650
720
1050
1160
1300
320
350
600
650
1050
1160
1300
1600
59.9
90
330
16 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Magnet Core
B-BMoving Side
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
120
(REMARK 2) 1800
(REMARK 2) 1700
58.3
150 H7Locate Ring
(REMARK 2) 1300
(REMARK 2) 1270[TIE-BAR DISTANCE-30]
566
917
350
400
650
850
750
1300
400
500
750
1050
570
120
917
1092
(REMARK 2) 1170
[TIE-BAR DISTANCE-30]
(REMARK 2) 1200
1600
90
330
C
C
Stationary Platen
Clamp Plate
Connector Box
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
16 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Magnet Core
A-AStationary Side
Displacement Detection Magnet Core
(REMARK 4)
※OptionMold Fall Protection Hook(Eye Bolt : M24)
30
29.9
52 49
B
B
A
A
D
150
140
150
25
52 25
15
180
250
C-C (1 : 6)Details of locating
Clamp PlateStationary Side Locate Ring of Stationary Platen
Locate Ring 2
Locate Ring 1 Stationary Platen
90°
(1.7)
R0.8
0.5
D (5 : 1)※OptionCenter Edge
STANDARD
MGA105 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of center hole is 60 mm. The ones of inner 12 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1771.slddrw3MGAA17710MGA105030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:20
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 10470 mm square 108 -115 mm square 1 -
809kN 815kN1056kg 1067kg
M24x60 16 16M16x55 8 8
Applied Mold Clamping Force 10000~10500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 10470 mm square 108 -115 mm square 1 -
809kN 815kN1056kg 1067kg
M24x60 16 16M16x55 8 8
Applied Mold Clamping Force 10000~10500kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
120
400
(REMARK 2) 1260
(REMARK 2) 1310
320
350
650
720
1050
1300
350
320
600
650
1050
1300
(REMARK 2) 1280[TIE-BAR DISTANCE-30]
120
570
(REMARK 2) 1230
[TIE-BAR DISTANCE-30]
1600
1800
1160
1160
58.3
(REMARK 2) 190059.9
(REMARK 2) 1850
90
330
16 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Moving Platen
Clamp Plate
Connector Box
Mold Fall Protection Block
8 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
Magnet Core
B-BMoving Side
Displacement Detection Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
120
(REMARK 2) 1850
(REMARK 2) 1310
(REMARK 2) 1260
150 H7Locate Ring
500
400
750
1300
350
400
500
650
750
917
1300
1092
917
1092
(REMARK 2) 1280[TIE-BAR DISTANCE-30]
120
570
(REMARK 2) 1230
[TIE-BAR DISTANCE-30]
180058.3
(REMARK 2) 1900
1600
850
90
330
C
C
Stationary Platen
Clamp Plate
Connector Box
12 x M16 Depth 26Bolt : M16 x 55Square Washer : M16
12 x M24 Depth 38Bolt : M24 x 60Square Washer : M24
Magnet Core
A-AStationary Side
Displacement Detection Magnet Core
(REMARK 4)
※OptionMold Fall Protection Hook(Eye Bolt : M24)
30
29.9
52 49
B
B
A
A
D
150
140
150
180
52
15
25
250
25
C-C (1 : 6)Details of locating
Clamp PlateStationary Side
Locate Ring ofStationary Platen
Locate Ring 2
Locate Ring 1
Stationary Platen
R0.8
(1.7)
90°
0.5
D (5 : 1)※OptionCenter Edge
STANDARD
MGA130 - ⑤④③②①
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of center hole is 60 mm. The ones of inner 12 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA1781.slddrw3MGAA17810MGA130030062003/11/03XXX9A-034-3
NAME
S-30300-002
1:22
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 12870 mm square 124 -115 mm square 1 -
927kN 1004kN1065kg 1084kg
M24x60 16 12M16x55 8 12
Applied Mold Clamping Force 13000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 12870 mm square 124 -115 mm square 1 -
927kN 1004kN1065kg 1084kg
M24x60 16 12M16x55 8 12
Applied Mold Clamping Force 13000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 217037
400
(REMARK 2) 1430[TIE-BAR DISTANCE -100]
1570
59.9
(REMARK 2) 1530
37
(REMARK 2)1920
90
(REMARK 2) 1280
(REMAEK 2) 1180
[TIE-BAR DISTANCE -100]
1060
750
325
375
375
Moving Platen
Clamp Plate
Mold Fall Protection Block
Displacement DetectionMagnet Core
B-BMoving Side
※OptionMold Fall Protection Hook(Eye Bolt : M24)
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
CLASS DEFINITION
① ② ③ ④ ⑤MGA160 -
Magnet Core
Sub Plate
Sub Plate
Cable Port
(REMARK 2) 1530
(REMARK 2) 2170
(REMARK 2) 1280
(REMARK 2) 1920
90
1176
1352
(REMARK 2) 1430[TIE-BAR DIDISTANCE -100]
37
1107
932
(REMARK 2) 1180
[TIE-BAR DISTANCE -100]
37
120 H7Locate Ring
750
385
385
335
C
C
Stationary Platen
Clamp Plate
A-AStationary Side
※OptionMold Fall Protection Hook(Eye Bolt : M24)
Sub Plate
Magnet Core
Displacement DetectionMagnet Core
Sub Plate
Cable Port
30
29.9 52 49
B
B
A
A
D
(REMARK4)
25 14.5
(52) (25)
110
120
(320)
120
150
C-C (1 : 7)Details of locating
Mounting Blockfor Locate Ring
Locate Ring ofStationary Platen
Locate Ring 2
Locate Ring 1
Stationary Platen
90°
(1.7)
0.5
R0.8
D (5 : 1)※OptionCenter Edge
STANDARD
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701. The diameter of inner 8 holes and other holes are 35 mm and 55 mm respectively. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA8200.slddrw3MGAA82000MGA160051252005/09/12
NAME
1:22
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 14870 mm square 160 -115 mm square 1 -
1176kN 1160kN1434kg 1428kg
M24x60 24 24M16x55 20 20M12x55 - 4
Applied Mold Clamping Force 14000~16000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 14870 mm square 160 -115 mm square 1 -
1176kN 1160kN1434kg 1428kg
M24x60 24 24M16x55 20 20M12x55 - 4
Applied Mold Clamping Force 14000~16000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 2450
(REMARK 2) 1800(REMARK 2) 2250
(REMARK 2) 1600
(REMARK 2) 1500
[TIE-BAR DISTANCE -100]
3737
1214
1444
(REMARK 2) 1700 [TIE-BAR DISTANCE -100]
75090
40059.9
452
452
402
※OptionMold Fall Protection Hook(Eye Bolt : M24)
Sub Plate
Sub Plate Displacement DetectionMagnet Core
Moving Platen
Clamp Plate
Mold Fall Protection Block
Magnet Core
Cable Port
(REMARK 2) 2450
(REMARK 2) 1800
(REMARK 2) 1600
(REMARK 2) 1500
[TIE-BAR DISTANCE -100]
(REMARK 2) 2250
1107
1557
37 37
(REMARK 2) 1700 [TIE-BAR DISTANCE -100] 120 H7
Locate Ring
750
90
472.5
472.5
422.5
C
C
Sub Plate
Stationary Platen
※OptionMold Fall Protection Hook(Eye Bolt : M24)
Displacement DetectionMagnet Core
Sub Plate
Clamp Plate
Magnet Core
Cable Port
52 4929.930
B
B
A
A
D
120
150
110
120
320
(25)
14.525
(52)
Locate Ring 2
Locate Ring ofStationary Platen
Locate Ring 1
Stationary PlatenMounting Blockfor Locate Ring
R0.8(1.7)
0.5
90°
STANDARD
(REMARK4)
A-AStationary SideB-B
Moving Side
D (5 : 1)※OptionCenter Edge
CLASS DEFINITION
MGA200 -
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701. The diameter of holes are 55 mm. If the diameter differs, it should be specified on the confirmation sheet at the time of order.
C-C (1 : 7)Details of locating
④ ⑤③②①
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA8210.slddrw3MGAA82100MGA200051252005/09/10
NAME
1:25
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 16870 mm square 172 -115 mm square - -
1264kN 1317kN1964kg 1958kg
M30x65 24 32M16x55 28 22M12x55 - 4
Applied Mold Clamping Force 18000~20000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 16870 mm square 172 -115 mm square - -
1264kN 1317kN1964kg 1958kg
M30x65 24 32M16x55 28 22M12x55 - 4
Applied Mold Clamping Force 18000~20000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 2450
(REMARK 2) 1800(REMARK 2) 2250
(REMARK 2) 1600
(REMARK 2) 1500
[TIE-BAR DISTANCE -100]
1764
3737
(REMARK 2) 1700 [TIE-BAR DISTANCE -100]
1214
90
59.9
750
400
452
402
452
Clamp Plate
Moving Platen
Magnet Core
Sub Plate
※OptionMold Fall Protection Hook(Eye Bolt : M24)
Mold Fall Protection Block
Displacement DetectionMagnet Core
Sub Plate
Cable Port
(REMARK 2) 2450
(REMARK 2) 1800
(REMARK 2) 1600
(REMARK 2) 1500
[TIE-BAR DISTANCE -100]
(REMARK 2) 2250
1107
1733
37 37
120 H7Rocate Ring
(REMARK 2) 1700 [TIE-BAR DISTANCE -100]
90
750
472.5
472.5
415.5
C
C
Magnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
Sub Plate
Clamp Plate
Stationary Platen
Sub Plate
Displacement DetectionMagnet Core
Cable Port
4952
30
29.9
B
B
A
A
D
120150
110
120
320
(25)
14.525
(52)
Locate Ring 1
Locate Ring of Stationary PlatenLocate Ring 2
Mounting Blockfor Locate Ring
Stationary Platen
0.5
R0.8(1.7)
90°
STANDARD
MGA250 - ⑤④③②①
C-C (1 : 7)Details of locating
D (5 : 1)※OptionCenter Edge
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701. The diameter of holes are 55 mm. If the diameterdiffers, it should be specified on the conTfirmation sheet at the time of order.
B-BMoving Side
(REMARK4)
A-AStationary Side
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA8220.slddrw3MGAA82200MGA250051252005/09/10
NAME
1:25
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 19270 mm square 212 -115 mm square - -
1558kN 1505kN1964kg 1958kg
M30x65 32 32M16x55 30 22M12x55 - 4
Applied Mold Clamping Force 22000~25000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 19270 mm square 212 -115 mm square - -
1558kN 1505kN1964kg 1958kg
M30x65 32 32M16x55 30 22M12x55 - 4
Applied Mold Clamping Force 22000~25000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
(REMARK 2) 2550
(REMARK 2) 1900
(REMARK 2) 2450
(REMARK 2) 1800
(REMARK 2) 1700
[TIE-BAR DISTANCE -100]
1764
3737
1374
(REMARK 2) 1800 [TIE-BAR DISTANCE -100]
1214
1384
90
59.9
750
400
452
452
402
Mold Fall Protection Block
Sub Plate
Displacement DetectionMagnet Core
Sub Plate
Moving Platen
Clamp PlateMagnet Core
※OptionMold Fall Protection Hook(Eye Bolt : M24)
Cable Port
(REMARK 2) 2550
(REMARK 2) 1900
(REMARK 2) 1800
(REMARK 2) 1700
[TIE-BAR DISTANCE -100]
(REMARK 2) 2450
37 37
1458
1107
1031
1733 120 H7Rocate Ring
(REMARK 2) 1800 [TIE-BAR DISTANCE -100]
750
90
472.5
472.5
422.5
C
C
Displacement DetectionMagnet Core
Sub Plate
※OptionMold Fall Protection Hook(Eye Bolt : M24)
Sub Plate
Stationary Platen
Clamp Plate
Magnet Core
B-BMoving Side
A-AStationary Side
Cable Port
29.930
52 49
B
B
A
A
D
120
150
110
120
320
(25)
14.525
(52)
Mounting Blockfor Locate Ring
Stationary Platen
Locate Ring 2Locate Ring of Stationary Platen
Locate Ring 1
90°
R0.8(1.7)
0.5
STANDARD
MGA300 - ⑤④③②①
C-C (1 : 7)Details of locating
D (5 : 1)※OptionCenter Edge
(REMARK4)
CLASS DEFINITION
①Primary ②Language on ③Working ④Rust proof arrangement ⑤Special specification power source operation panel temperature range
2: 200V/220V J: Japanese not specified: 0~80 ℃ not specified:not included not specified:not included 3: 380V E: English H1 : 0~150 ℃ N :included S :included 4: 440V H2 : 0~180 ℃ 5: 480V
[REMARKS]1. Minimum daylight should be 155 mm. 2. Dimensions of platens and tie-bars shown above are reference only. 3. Option (if any) should be specified on the confirmation sheet at the time of order. 4. If the diameter of locate ring is different, it should be specified on the confirmation sheet at the time of order. 5. The hole position of ejector is according to JIS B 6701.The diameter of holes are 55 mm. If the diameterdiffers, it should be specified on the confirmation sheet at the time of order.
DESIGNED BYDATE MODEL DWG.NO. FILE.NO.SCALE REVISION HISTORY
MGAA8230.slddrw3MGAA82300MGA300051252005/09/10
NAME
1:25
A3
Mag Clamp Layout
Specifications
Moving Side Stationary Side
75 mm square - 22870 mm square 244 -115 mm square - -
1793kN 1788kN2262kg 2260kg
M30x65 32 32M16x55 34 26M12x55 - 4
Applied Mold Clamping Force 28000~30000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core
Specifications
Moving Side Stationary Side
75 mm square - 22870 mm square 244 -115 mm square - -
1793kN 1788kN2262kg 2260kg
M30x65 32 32M16x55 34 26M12x55 - 4
Applied Mold Clamping Force 28000~30000kN
Type
Mounting Bolt
Maximum Clamping Force
Accessories
Mass of Plate
Number of Magnet Core