Partner For Level & Flow Measurement
Power Plant Solutions
Steam Turbine
Turbo Generator
Condensor / Heat Exchanger
Condensate Polishing Unit (CPU)
Coal Handling Plant (CHP)
Ash Handling Plant (AHP)
Fuel Oil Handling
DM Plant
Pre Treatment - Water Treatment Plant (PT-WTP)
Effluent Treatment Plant (ETP)
Fire Protection
SBEM has solution for Level & Flow Measuring
equipments in following packages
in Thermal Power Plant
Our ambition to grow into India's finest Level and Flow
measurement solutions company, SBEM serves its
customers to the best of its ability. Our one of the key
segment is Thermal Power Plant-Instrumentation.
SBEM prov ides equipment , which ensures
comprehensive measurement of all essential level & flow
parameters of the thermal Power Plant. Covering end-to-
end processes in a thermal plant, SBEM provides high
precision switches and transmitters for all duties.
About SBEMSBEM Pvt. Ltd. India is pioneer in the field of Level
Instrumentation Firmament. Started in 1974, we have
established ourselves as a complete solution provider
to various industrial segments. It is this domain
experience of more than 3 decades, which sets us
apart from our competition. Since building the first
ever Tank Level Gauge in late 70s, SBEM has been the
first Indian brand in indigenous level measurement
technology. The company has also ventured
extensively into the flow measurement domain.
Having established itself as a business leader in
industrial instrumentation, SBEM has strived hard to
raise the bar in measurement applications. To its credit,
the company has a ISO 9001 certification for its quality
systems and also a DSIR-recognized technology and
design-centre. Add to this a dedicated R&D team,
which incorporates cutting-edge technology matching
international standards are customized to Indian
conditions.
Using our indigenous expertise, we offer diverse
solutions to successfully cover every aspect of level
measurement for both liquid and solid applications.
Our foray into flow measurement has also been
flourishing, with products based on multiple
technologies being introduced into the market.
Anything to everything in POWER PLANT SOLUTION:
3Power Plant Solutions
Coal Handling
Coal is the main fuel in most of the power plants in India. It is stored in bunkers (normally up to 30mtr.). During filling and withdrawal of coal from bunkers, there will be heavy dust inside the bunker. Reliable continuous level measurement guarantees uninterrupted supply for the furnace and point level sensors prevent overfilling in the bunkers and hoppers. Air purging facility keeps the dust from accumulating inside the antenna.
Solution
Continuous Level: Model 138 K58 Pulse Radar
Point Level:Model 135LCRotary Paddle Type Level Switch
Ash Handling
Fly ash filtered out of the flue gases is stored in large silos up to 70mtrs. in height. Since fly ash particles are very fine and tend to form a coating, non-contact type level measuring instrument is very much essential. Air purging facility keeps the dust from accumulating inside the antenna. Since fly ash also adds to the revenue of the industry, accurate and reliable continuous level measurement is needed.
Solution
The ash particles in the flue gas are filtered out with large electrostatic filters and stored in part in very large silos. In those silos that can be up to 70 m high, non-contact measurement of the contents with a 138 K58 radar sensor is the ideal solution. All types of fly ash can be measured reliably with it.
Continuous Level: Model 138 K58 Pulse Radar
Rail CarShip
CollectionHopper
CollectionHopper
Breaker
Coal PileCoal Silo
In Plant
To Boiler
Point Level: Model 114RFS RF Admittance
Steam Turbine
Turbo Generator
Condensor / Heat Exchanger
Condensate Polishing Unit (CPU)
Coal Handling Plant (CHP)
Ash Handling Plant (AHP)
Fuel Oil Handling
DM Plant
Pre Treatment - Water Treatment Plant (PT-WTP)
Effluent Treatment Plant (ETP)
Fire Protection
SBEM has solution for Level & Flow Measuring
equipments in following packages
in Thermal Power Plant
Our ambition to grow into India's finest Level and Flow
measurement solutions company, SBEM serves its
customers to the best of its ability. Our one of the key
segment is Thermal Power Plant-Instrumentation.
SBEM prov ides equipment , which ensures
comprehensive measurement of all essential level & flow
parameters of the thermal Power Plant. Covering end-to-
end processes in a thermal plant, SBEM provides high
precision switches and transmitters for all duties.
About SBEMSBEM Pvt. Ltd. India is pioneer in the field of Level
Instrumentation Firmament. Started in 1974, we have
established ourselves as a complete solution provider
to various industrial segments. It is this domain
experience of more than 3 decades, which sets us
apart from our competition. Since building the first
ever Tank Level Gauge in late 70s, SBEM has been the
first Indian brand in indigenous level measurement
technology. The company has also ventured
extensively into the flow measurement domain.
Having established itself as a business leader in
industrial instrumentation, SBEM has strived hard to
raise the bar in measurement applications. To its credit,
the company has a ISO 9001 certification for its quality
systems and also a DSIR-recognized technology and
design-centre. Add to this a dedicated R&D team,
which incorporates cutting-edge technology matching
international standards are customized to Indian
conditions.
Using our indigenous expertise, we offer diverse
solutions to successfully cover every aspect of level
measurement for both liquid and solid applications.
Our foray into flow measurement has also been
flourishing, with products based on multiple
technologies being introduced into the market.
Anything to everything in POWER PLANT SOLUTION:
3Power Plant Solutions
Coal Handling
Coal is the main fuel in most of the power plants in India. It is stored in bunkers (normally up to 30mtr.). During filling and withdrawal of coal from bunkers, there will be heavy dust inside the bunker. Reliable continuous level measurement guarantees uninterrupted supply for the furnace and point level sensors prevent overfilling in the bunkers and hoppers. Air purging facility keeps the dust from accumulating inside the antenna.
Solution
Continuous Level: Model 138 K58 Pulse Radar
Point Level:Model 135LCRotary Paddle Type Level Switch
Ash Handling
Fly ash filtered out of the flue gases is stored in large silos up to 70mtrs. in height. Since fly ash particles are very fine and tend to form a coating, non-contact type level measuring instrument is very much essential. Air purging facility keeps the dust from accumulating inside the antenna. Since fly ash also adds to the revenue of the industry, accurate and reliable continuous level measurement is needed.
Solution
The ash particles in the flue gas are filtered out with large electrostatic filters and stored in part in very large silos. In those silos that can be up to 70 m high, non-contact measurement of the contents with a 138 K58 radar sensor is the ideal solution. All types of fly ash can be measured reliably with it.
Continuous Level: Model 138 K58 Pulse Radar
Rail CarShip
CollectionHopper
CollectionHopper
Breaker
Coal PileCoal Silo
In Plant
To Boiler
Point Level: Model 114RFS RF Admittance
4
Main Oil Tanks
Capacitance Type Level Transmitter or Guided Wave Radar Level Transmitter is used in Main Oil Tank (MOT) having Turbine Oil. Turbine Oil is used for lubrication of turboset. Three Nos Transmitters are used in each tank. Output of each transmitter should be almost similar. BHEL uses 2 out of 3 logic, accurate and repeatable measurement is extremely essential, else the turbine will trip. As capacitance type technology depends of various process parameter of liquid, GWR is preferred nowadays due to its least dependence of process parameter.
Capacitance Type Single Point Level switch (Model 114) is used in Control Fluid Tank (CFT) having Fire Resistant Fluid (FRF). FRF is used as electro-hydraulic control fluids in Turbine Governor Systems.
Solution
Continuous Level: Model 132 GWRGuided Wave RadarLevel Transmitter
Point Level: Model 114 MLSCapacitance Level Switch
Fuel Oil Storage
Application:
Fuel-fed ignitors initiate the boiler flame in coal-fed plants using light diesel oil or heavy fuel oil.
Continuous and accurate measurement of level with transmitter to enable monitoring the stock in control room is preferred. As the liquid stored is hazardous the transmitter used has to be certified for hazardous area application. To add to the safety, high and low level switches in explosion proof enclosure , which are independent of transmitters are used.
Solution
Point Level:Model 137 D/PDisplacer Level Switch
Power Plant Solutions
Point Level: Model 137 EAFloat Type Level Switch
Model 133+TWTFloat & Tape
5
Filter Beds
Application:
Following the clarification phase of water treatment, pre-filtered water passes from an inlet channel and onto a filtration bed. As it passes through the bed's media—sand or anthracite in depth-filtration types; cloth or synthetic membranes in surface-filtration types—the water is cleansed of its fine-grained suspended solids.
Filter tank level triggers the backwash cycle. As solids accumulate within the filter, head loss begins to build up and water level increases in the filter tank. A pre-determined tank level indicates that terminal head loss value has been reached, and that the filter must now be backwashed to remove the suspended solids.
Solution
Differential Level: Model 104 LOHLoss of Head Indicator Transmitter
Power Plant Solutions
Condensate Storage In Condensate Polishing UnitIn Demineralisation Plant
Application:
When the condenser hotwell level reaches the high point, a valve opens to drain excess condensate from the hotwell to a condensate storage tank. When loss of condensate from the turbine cycle is reflected in a low level in the hotwell, a make-up valve opens in the storage tank to supply make-up water to the condenser hotwell.
Proper functioning of the liquid level control in the condensate storage tank ensures the proper supply of make-up water.
Solution
Continuous Level: Model 136 ULTUltrasonic LevelTransmitter
Indication:Model 131 Float & Board
Point Level:Model 137DDisplacerLevel Switch
Model 103 HPTHydrostatic Pressure Transmitter
4
Main Oil Tanks
Capacitance Type Level Transmitter or Guided Wave Radar Level Transmitter is used in Main Oil Tank (MOT) having Turbine Oil. Turbine Oil is used for lubrication of turboset. Three Nos Transmitters are used in each tank. Output of each transmitter should be almost similar. BHEL uses 2 out of 3 logic, accurate and repeatable measurement is extremely essential, else the turbine will trip. As capacitance type technology depends of various process parameter of liquid, GWR is preferred nowadays due to its least dependence of process parameter.
Capacitance Type Single Point Level switch (Model 114) is used in Control Fluid Tank (CFT) having Fire Resistant Fluid (FRF). FRF is used as electro-hydraulic control fluids in Turbine Governor Systems.
Solution
Continuous Level: Model 132 GWRGuided Wave RadarLevel Transmitter
Point Level: Model 114 MLSCapacitance Level Switch
Fuel Oil Storage
Application:
Fuel-fed ignitors initiate the boiler flame in coal-fed plants using light diesel oil or heavy fuel oil.
Continuous and accurate measurement of level with transmitter to enable monitoring the stock in control room is preferred. As the liquid stored is hazardous the transmitter used has to be certified for hazardous area application. To add to the safety, high and low level switches in explosion proof enclosure , which are independent of transmitters are used.
Solution
Point Level:Model 137 D/PDisplacer Level Switch
Power Plant Solutions
Point Level: Model 137 EAFloat Type Level Switch
Model 133+TWTFloat & Tape
5
Filter Beds
Application:
Following the clarification phase of water treatment, pre-filtered water passes from an inlet channel and onto a filtration bed. As it passes through the bed's media—sand or anthracite in depth-filtration types; cloth or synthetic membranes in surface-filtration types—the water is cleansed of its fine-grained suspended solids.
Filter tank level triggers the backwash cycle. As solids accumulate within the filter, head loss begins to build up and water level increases in the filter tank. A pre-determined tank level indicates that terminal head loss value has been reached, and that the filter must now be backwashed to remove the suspended solids.
Solution
Differential Level: Model 104 LOHLoss of Head Indicator Transmitter
Power Plant Solutions
Condensate Storage In Condensate Polishing UnitIn Demineralisation Plant
Application:
When the condenser hotwell level reaches the high point, a valve opens to drain excess condensate from the hotwell to a condensate storage tank. When loss of condensate from the turbine cycle is reflected in a low level in the hotwell, a make-up valve opens in the storage tank to supply make-up water to the condenser hotwell.
Proper functioning of the liquid level control in the condensate storage tank ensures the proper supply of make-up water.
Solution
Continuous Level: Model 136 ULTUltrasonic LevelTransmitter
Indication:Model 131 Float & Board
Point Level:Model 137DDisplacerLevel Switch
Model 103 HPTHydrostatic Pressure Transmitter
6
Boiler Blowdown Tank
Application:
The concentration of undesirable solids in boiler feed water can be reduced through the use of a continuous purge or blowdown system. A blowdown tank receives continuous blowdown from the steam drum and blowdowns of variable temperatures and pressures from the steam generator. A blowdown tank can also function as a gravity feed drain for the steam generator when the generator is drained for maintenance.
Good boiler blowdown practices can greatly reduce a boiler's water treatment needs and operation costs. Combustible mixtures left in a boiler due to improper purges, however, have been known to cause catastrophic explosions. Proper tank level controls are essential to ensure a safe and effective boiler blowdown system.
Solution
Continuous Level:Model 132 GWR Guided Wave Radar Level Transmitter
Power Plant Solutions
Acid Storage & Alkali (NaOH) Storage Tanks
Continuous Level: Model 138 C51, 138 K55Pulse Radar
Solution
Model 130 IC/RCConductivity Level Switch
Point Level:Model 137 YDisplacer Level Switch in Polypropylene wetted parts
Model 132 GWRGuided Wave Radar Level Transmitter
Model 137CFloat Level Switch in Polypropylene wetted parts
77
Flash TankApplication:
A flash tank serves as a collection system for a variety of condensate drain lines. Flash tanks receive high pressure condensate which is then exposed to a low pressure steam source.
When this occurs, a certain percentage of condensate will “flash” to steam at the lower pressure. This steam can be “recycled” on other low pressure steam heat transfer applications.
Level measurement is necessary to control flash tank level. The challenges are elevated temperatures and pressures.
Continuous Level:Model 132 GWR Guided Wave RadarLevel Transmitter
Point Level: Model 137 EAFloat Type Level Switch with External Cage
Power Plant Solutions
Demineralization Tanks
Application:
Because modern high-pressure boilers evaporate large volume of water every hour, the purity of feed water circulating inside the boiler is critical . Chemical treatment reduces scale-forming materials and corrosive oxygen content. A Feed water Evaporator can be used as an alternative method to chemicals by removing impurities through evaporating raw water with extraction steam. Most often, the purity of feed water is achieved by chemical treatment.
Solution
Chemicals used for water treatment can include caustics, sodium hypochloride, sulphuric acid or other additives, individual chemistry and storage requirements will dictate the type of level instrumentation selected.
Continuous Level:Model 136 ULTUltrasonic Level Transmitter
Model 133+TWTFloat & Tape
Point Level:Model 137 EA/CFloat Type Level Switch with External Chamber
Indication:Model 131 Float & Board
Model 103 HPTHydrostatic PressureTransmitter
6
Boiler Blowdown Tank
Application:
The concentration of undesirable solids in boiler feed water can be reduced through the use of a continuous purge or blowdown system. A blowdown tank receives continuous blowdown from the steam drum and blowdowns of variable temperatures and pressures from the steam generator. A blowdown tank can also function as a gravity feed drain for the steam generator when the generator is drained for maintenance.
Good boiler blowdown practices can greatly reduce a boiler's water treatment needs and operation costs. Combustible mixtures left in a boiler due to improper purges, however, have been known to cause catastrophic explosions. Proper tank level controls are essential to ensure a safe and effective boiler blowdown system.
Solution
Continuous Level:Model 132 GWR Guided Wave Radar Level Transmitter
Power Plant Solutions
Acid Storage & Alkali (NaOH) Storage Tanks
Continuous Level: Model 138 C51, 138 K55Pulse Radar
Solution
Model 130 IC/RCConductivity Level Switch
Point Level:Model 137 YDisplacer Level Switch in Polypropylene wetted parts
Model 132 GWRGuided Wave Radar Level Transmitter
Model 137CFloat Level Switch in Polypropylene wetted parts
77
Flash TankApplication:
A flash tank serves as a collection system for a variety of condensate drain lines. Flash tanks receive high pressure condensate which is then exposed to a low pressure steam source.
When this occurs, a certain percentage of condensate will “flash” to steam at the lower pressure. This steam can be “recycled” on other low pressure steam heat transfer applications.
Level measurement is necessary to control flash tank level. The challenges are elevated temperatures and pressures.
Continuous Level:Model 132 GWR Guided Wave RadarLevel Transmitter
Point Level: Model 137 EAFloat Type Level Switch with External Cage
Power Plant Solutions
Demineralization Tanks
Application:
Because modern high-pressure boilers evaporate large volume of water every hour, the purity of feed water circulating inside the boiler is critical . Chemical treatment reduces scale-forming materials and corrosive oxygen content. A Feed water Evaporator can be used as an alternative method to chemicals by removing impurities through evaporating raw water with extraction steam. Most often, the purity of feed water is achieved by chemical treatment.
Solution
Chemicals used for water treatment can include caustics, sodium hypochloride, sulphuric acid or other additives, individual chemistry and storage requirements will dictate the type of level instrumentation selected.
Continuous Level:Model 136 ULTUltrasonic Level Transmitter
Model 133+TWTFloat & Tape
Point Level:Model 137 EA/CFloat Type Level Switch with External Chamber
Indication:Model 131 Float & Board
Model 103 HPTHydrostatic PressureTransmitter
79
Cooling Tower
Open-system cooling towers reject waste heat from the steam cycle by exposing the cooling water directly to the atmosphere. The majority of heat removed is due to evaporation and the remaining cooled water drops into a collection tank. Level control applications include a high level switch to avoid overflow conditions in the cooling tower tank.
In induced draft cooling tower, measurement of lubricating oil level for fan bearing , is very critical. It is common to use either continuous level transmitter or a low level switch, to replenish lubricating oil stock if
Point Level:Model 137 EAFloat Type Level Switch with External CageGear Box Oil Level measurement
Model 137 D Displacer Level Switch
Flow Measurement In Waste Water/ Effluent Treatment Plant Water Intake
Water Flow Measurement Model 151 MFMElectromagnetic Flow Meter
Power Plant Solutions
Solution
Continuous Level:Model 103 CLTCapacitance
Model 130 IC/RCConductivity Level Switch
Model 103 HPTHydrostatic PressureTransmitter
8
Open Atmosphere Sumps And Open Channels In Waste Water/ Effluent Treatment Plants
Application:
Power generating facilities have large, open atmosphere collection basins known as sumps that are usually found in
Waste water treatment areas. Often constructed of concrete with depths ranging from one to four metres, sumps function as collection and treatment sites for waste liquids ranging from storm water drains to excess make-up water. With many possible uses for sumps, chemical composition and temperatures will vary.
Proper level control will help ensure the continuous operation of collection and processing of collected water. Level controls in these areas must often tolerate corrosive media, harsh chemicals, liquids with high solids content and harsh weather conditions.
Continuous Level:Model 136 ULTUltrasonic Level Transmitter With Model 191 Flow Indicator Totaliser
Model 103 CLTCapacitance
Point Level: Model 137DDisplacerLevel Switch
Solution
Power Plant Solutions
Condenser & Condensate Tanks
IBR approved switches for high Pressures and high temperatures.
Solution
Point Level:Model 137 EA Side Mounted Float type level switchWith External chamber
Model 137 D Top mounted Displacer Level Switch
Model 104ROFRate of Flow Level TransmitterControl Room Display:
Model 191Flow Indicator Totaliser
Display in field:Model 103HTL
79
Cooling Tower
Open-system cooling towers reject waste heat from the steam cycle by exposing the cooling water directly to the atmosphere. The majority of heat removed is due to evaporation and the remaining cooled water drops into a collection tank. Level control applications include a high level switch to avoid overflow conditions in the cooling tower tank.
In induced draft cooling tower, measurement of lubricating oil level for fan bearing , is very critical. It is common to use either continuous level transmitter or a low level switch, to replenish lubricating oil stock if
Point Level:Model 137 EAFloat Type Level Switch with External CageGear Box Oil Level measurement
Model 137 D Displacer Level Switch
Flow Measurement In Waste Water/ Effluent Treatment Plant Water Intake
Water Flow Measurement Model 151 MFMElectromagnetic Flow Meter
Power Plant Solutions
Solution
Continuous Level:Model 103 CLTCapacitance
Model 130 IC/RCConductivity Level Switch
Model 103 HPTHydrostatic PressureTransmitter
8
Open Atmosphere Sumps And Open Channels In Waste Water/ Effluent Treatment Plants
Application:
Power generating facilities have large, open atmosphere collection basins known as sumps that are usually found in
Waste water treatment areas. Often constructed of concrete with depths ranging from one to four metres, sumps function as collection and treatment sites for waste liquids ranging from storm water drains to excess make-up water. With many possible uses for sumps, chemical composition and temperatures will vary.
Proper level control will help ensure the continuous operation of collection and processing of collected water. Level controls in these areas must often tolerate corrosive media, harsh chemicals, liquids with high solids content and harsh weather conditions.
Continuous Level:Model 136 ULTUltrasonic Level Transmitter With Model 191 Flow Indicator Totaliser
Model 103 CLTCapacitance
Point Level: Model 137DDisplacerLevel Switch
Solution
Power Plant Solutions
Condenser & Condensate Tanks
IBR approved switches for high Pressures and high temperatures.
Solution
Point Level:Model 137 EA Side Mounted Float type level switchWith External chamber
Model 137 D Top mounted Displacer Level Switch
Model 104ROFRate of Flow Level TransmitterControl Room Display:
Model 191Flow Indicator Totaliser
Display in field:Model 103HTL
10
Lubrication Oil Tanks
Application:
Generators and gas turbines will have integral lubricating systems to prevent damage caused by excessive friction. Often a portion of the lubricating oil is used in the hydraulic oil systems for hydraulic control devices. Lubricating oil is typically stored in integral stainless steel and carbon steel tanks that are monitored for level. A generator gearbox
lube oil system may have a reservoir with a capacity of 3,000 gallons and a turbine oil system may have a reservoir with a capacity of 150 gallons.
Adequate level monitoring of lube oil reservoirs will ensure the proper functioning of turbines, electrical generators and other equipment with integral lubrication systems.
Solution
Continuous Level:Model 136 ULTUltrasonic Level Transmitter
Model 132 GWRGuided WaveRadar Transmitter
Model 138Pulse Radar
Point Level: Model 137 EAFloat Type Level Switch
Water Wash Tanks
Application:
The compressor of a gas turbine ingests a large amount of air containing particulate matter, aerosols of hydrocarbons and other organic compounds and gases. Although the larger solid particles are filtered out, the other compounds are deposited on the compressor blades. Compressor washing removes this deposited fouling. Also used for cleaning generator or other machinery and equipment components, water wash is periodically discharged as waste water.
Solution
Continuous Level:Model 136 ULT Ultrasonic Level Transmitter Switch
Point Level:Model 137DDisplacer Level
Power Plant Solutions
Model 114 MLSCapacitance Level Switch
Model 103 CLTCapacitance
Model 103 HPTHydrostatic PressureTransmitter
11
Water Services
Application:
Service water is utilized for general plant services that include pump and instrument seal water, fire water, demineralization, cooling and make-up water supply. Storage tanks with a capacity to support three days to one week of operation, allow continued plant operations in the event the supply of water is interrupted. Collectors and storage tanks are typically fixed roof, vertical cylindrical steel tanks.
Solution
Continuous Level:Model 136 ULTUltrasonic Level Transmitter
Model 132 GWRGuided Wave RadarTransmitter
Point Level:Model 137DDisplacerLevel Switch
End User Location
MAHAGENCO Khaparkheda, Bhusawal, Koradi, Chandrapur, Paras, Parali
MPGENCO Satpura, Malwa
APGENCO Rayalseema
Punjab State Electricity Board Bhatinda
Gujarat State Electricity Board Ukai, Uttaran, Pipavav, Navi Naroli
NTPC Vindhyachal, Sipat, Barh, Korba, Ramagundam, Unchahar,
Reliance Energy Dahanu, Rosa, Krishnapatnam, Sasan
Essar Power Mahan
Jaypee Power Bina
Coastal Energen Pvt. Ltd. Tuticorin
Neyveli Lignite Barsingsar
Pragati Power Bawana
Jindal Steel & Power Ltd. Tarapur, Dongamohua, Ratnagiri, Tamnar, Angul. Bellary
Aravalli Power Jhajhar
Lanco Infratech, Gurgaor Udupi, Amarkantak, Wardha, Kondapalli, Anpara
Meenakshi Energy Krishnapatnam
GMR Energy Limited Rajkheda
GVK Power Punjab
Hindalco Mahan, Lapanga, Hirakund, Moori, Ranchi
India Bulls Amravati. Nasik
Adani Power Mundra, Tiroda, Kawai
Major projects handled in Thermal Power Sectors
Power Plant Solutions
Model 103 HPTHydrostatic Pressure Transmitter
Control Room Display:Model 176Digital Process Indicator
Display in field:Model 103HTL
10
Lubrication Oil Tanks
Application:
Generators and gas turbines will have integral lubricating systems to prevent damage caused by excessive friction. Often a portion of the lubricating oil is used in the hydraulic oil systems for hydraulic control devices. Lubricating oil is typically stored in integral stainless steel and carbon steel tanks that are monitored for level. A generator gearbox
lube oil system may have a reservoir with a capacity of 3,000 gallons and a turbine oil system may have a reservoir with a capacity of 150 gallons.
Adequate level monitoring of lube oil reservoirs will ensure the proper functioning of turbines, electrical generators and other equipment with integral lubrication systems.
Solution
Continuous Level:Model 136 ULTUltrasonic Level Transmitter
Model 132 GWRGuided WaveRadar Transmitter
Model 138Pulse Radar
Point Level: Model 137 EAFloat Type Level Switch
Water Wash Tanks
Application:
The compressor of a gas turbine ingests a large amount of air containing particulate matter, aerosols of hydrocarbons and other organic compounds and gases. Although the larger solid particles are filtered out, the other compounds are deposited on the compressor blades. Compressor washing removes this deposited fouling. Also used for cleaning generator or other machinery and equipment components, water wash is periodically discharged as waste water.
Solution
Continuous Level:Model 136 ULT Ultrasonic Level Transmitter Switch
Point Level:Model 137DDisplacer Level
Power Plant Solutions
Model 114 MLSCapacitance Level Switch
Model 103 CLTCapacitance
Model 103 HPTHydrostatic PressureTransmitter
11
Water Services
Application:
Service water is utilized for general plant services that include pump and instrument seal water, fire water, demineralization, cooling and make-up water supply. Storage tanks with a capacity to support three days to one week of operation, allow continued plant operations in the event the supply of water is interrupted. Collectors and storage tanks are typically fixed roof, vertical cylindrical steel tanks.
Solution
Continuous Level:Model 136 ULTUltrasonic Level Transmitter
Model 132 GWRGuided Wave RadarTransmitter
Point Level:Model 137DDisplacerLevel Switch
End User Location
MAHAGENCO Khaparkheda, Bhusawal, Koradi, Chandrapur, Paras, Parali
MPGENCO Satpura, Malwa
APGENCO Rayalseema
Punjab State Electricity Board Bhatinda
Gujarat State Electricity Board Ukai, Uttaran, Pipavav, Navi Naroli
NTPC Vindhyachal, Sipat, Barh, Korba, Ramagundam, Unchahar,
Reliance Energy Dahanu, Rosa, Krishnapatnam, Sasan
Essar Power Mahan
Jaypee Power Bina
Coastal Energen Pvt. Ltd. Tuticorin
Neyveli Lignite Barsingsar
Pragati Power Bawana
Jindal Steel & Power Ltd. Tarapur, Dongamohua, Ratnagiri, Tamnar, Angul. Bellary
Aravalli Power Jhajhar
Lanco Infratech, Gurgaor Udupi, Amarkantak, Wardha, Kondapalli, Anpara
Meenakshi Energy Krishnapatnam
GMR Energy Limited Rajkheda
GVK Power Punjab
Hindalco Mahan, Lapanga, Hirakund, Moori, Ranchi
India Bulls Amravati. Nasik
Adani Power Mundra, Tiroda, Kawai
Major projects handled in Thermal Power Sectors
Power Plant Solutions
Model 103 HPTHydrostatic Pressure Transmitter
Control Room Display:Model 176Digital Process Indicator
Display in field:Model 103HTL
Head Office: 39’ Electronic Co-operative Estate, Pune-Satara Road, Pune - 411 009, IndiaTel. +91 20 41030100, 24220505, Fax +91 20 24215670, Email: [email protected]
Works: 692/A Bibwewadi Industrial Estate, Pune-Satara Road, Pune - 411 039
Mumbai Tel +91 22 [email protected] www.sbem-india.com
ISO 9001:2008
ChennaiTel +91 44 [email protected]
Delhi Tel +91 11 [email protected]
PuneTel +91 20 [email protected]
SBEM Pvt. Ltd.
LF
-30
0-0
81
2-R