Parklet to occupy 2 parking spaces max.36' max.
7' max. 1
5' clear zone min.(adjacent to building or at
edge of sidewalk pavement
Existing concrete sidewalk
Existing brick pavement Side
wal
k Zo
nePa
rkin
g/Pa
rkle
tZo
neTr
affic
Lan
e(s)
BUILDING
3
4
- Deflectors placed 3'from "T" striping oneach side of the parklet
108" in height mustremain clear of anyobstruction
12" max. gap
between face ofcurb and parklet
platform
Flowline of gutter to bemaintained
Parklet Floor structuresupports to be designed not
to obstruct drainage ordamage street pavements
Platform to be at the sameelevation as the top of the curb
Precast Concrete Planter(Deflector - Type 1)
Flexible Delineator(Deflector - Type 2)
1 Deck Structure /Elevated Surface
2 Safety Barrier 3 4 Site FurnishingsMetal RailingPlantersOther ______________
Type 1Precast Conc. Planter
Type 2Flexible DelineatorVertical Barricade
Powdercoated MetalFinished WoodSturdy Composite or Molded PlasticMolded Resin
Other ________________________
UmbrellasSolar Lighting (provided by DSI)
Worksheet InstructionsBusiness to check materials proposed.Submit product information for "Other"elements to the City for approval.
Tables, Chairs, and Benches
Wood DeckingComposite Decking (wood and plastic)PVC DeckingPedestal and Paver System
TRAFFIC LANEspeed limit 30 mph or less
Deflectors (standard element)
Other ______________
Existing treein grate
- At least 12" away fromedge of traffic lane
2Safety Barrier
Parklet Layout - Deck Structure
May 4, 2021Massie Massie + AssociatesSheet 01
Parklet to occupy 2 parking spaces max.
Flowline of gutterto be maintained
Shipping container structuresupports to be designed not
to obstruct drainage40' max. when parking spaces are 23'+ in length
7' max. 1
2
5' clear zone min.(edge of sidewalk pavement
or adjacent to building)
Existing concrete sidewalkExisting brick pavement
Side
wal
k Zo
nePa
rkin
g/Pa
rkle
tZo
neTr
affic
Lan
e(s)
BUILDING
Deflectors placedadjacent to containeron each side of theparklet, maintain max.distance betweenadjacent parking
108" in height mustremain clear of anyobstruction
4
4
-3
8' typ.Precast Concrete Planter(Deflector - Type 1)
Flexible Delineator(Deflector - Type 2)
1 Shipping Container Structure 2 Safety Barrier 3 4 Site FurnishingsMetal RailingPlantersOther ______________
Type 1Precast Conc. Planter
Type 2Flexible DelineatorVertical Barricade
Powdercoated MetalFinished WoodSturdy Composite or Molded PlasticMolded Resin
Other ________________________
UmbrellasSolar Lighting (provided by DSI)
Worksheet InstructionsBusiness to check materials proposed.Submit product information for "Other"elements to the City for approval.
Tables, Chairs, and BenchesCompliance with International BuildingCode, Section 3115: Intermodal ShippingContainersSealed structural engineer or architect plansindicating structural calculations for thecontainer if is altered
TRAFFIC LANEspeed limit 30 mph or less
Ramps 6" high or less can besloped at 1" per foot without
handrails, Ramps over 6" highcan be sloped at 1" per foot
with handrails or 916" per foot
without handrails.No parking meters, poles, or
other obstructions to interferewith the ramp
5' landing 6' ramp
3' min.
Deflectors (standard element)
Sealed structural engineer or architect plansindicating anchorage method and calculationsshowing 115 mph wind rating and Exposure C
Required City Submittals
Existing treein grate
- At least 12" away fromedge of traffic lane
Ramp
Safety Barrier
Container structure to beplaced 12" over the edge ofthe curb so as not to extend
farther than 7' from the face ofthe curb. Container to be level
with solid structural supports
Parklet Layout - Shipping Container Structure
May 4, 2021Massie Massie + AssociatesSheet 02
Parklet to occupy 2 parking spaces max.
Flowline of gutterto be maintained
36' max.
7' max. 1
5' clear zone min.(adjacent to building or at
edge of sidewalk pavement
Existing concrete sidewalk
Existing brick pavement Side
wal
k Zo
nePa
rkin
g/Pa
rkle
tZo
neTr
affic
Lan
e(s)
BUILDING
3
4
1 Street Surface 2 Safety Barrier 3 Deflectors (standard element)
4 Site Furnishings
-- Deflectors placed 3'
from "T" striping oneach side of the parklet
108" in height mustremain clear of anyobstruction
TRAFFIC LANEspeed limit 30 mph or less
2
Precast Concrete Planter(Deflector - Type 1)
Flexible Delineator(Deflector - Type 2)
5'
5' landing
6' rampMin. 5'x5' turningarea at the top and
bottom of the ramp
Ramps 6" high or less canbe sloped at 1" per foot
without handrails, Rampsover 6" high can be
sloped at 1" per foot withhandrails or 9
16" per footwithout handrails
5'x5'turning
area
Ramp
5'x5'turning
area
Metal RailingPlantersOther ______________
Type 1Precast Conc. Planter
Type 2Flexible DelineatorVertical Barricade
Powdercoated MetalFinished WoodSturdy Composite or Molded PlasticMolded Resin
Other ________________________
UmbrellasSolar Lighting (provided by DSI)
Worksheet InstructionsBusiness to check materials proposed.Submit product information for "Other"elements to the City for approval.
Tables, Chairs, and BenchesExisting Road SurfaceRubber MatsOutdoor Pavement CoveringOther ______________
Existing treein grate
At least 12" away fromedge of traffic laneSafety Barrier
Parklet Layout - Street Surface
May 4, 2021Massie Massie + AssociatesSheet 03
Parklet Structure Recommendations
Sheet 04
1Requirements
Composite Decking
Outdoor Pavement Covering
Modified Shipping Container and Ramp
Pedestal and Paver System
1. Structure shall be made of all-weather material.2. Decking shall be able to handle a live load of 150 pounds per square foot.3. All cross slopes of structure shall meet all Illinois Accessibility Codes. Cross slope of surfaces must not exceed 2% (less than 14" vertical change for every 12" horizontal length)4. Maximum parklet dimensions to be 7'x36' unless approval is provided by the City. In all cases there must be a 3' offset from the parking space "T" pavement striping to the required deflectors.5. Shipping Containers must: a. Comply with International Building Code, Section 3115: Intermodal Shipping Containers b. Side walls to be 48" high or less. Any structure above this height to receive approval from the Department of Public Works to ensure sight visibility is not blocked. c. Be painted. No exposed rust or discoloration of the metal surface is allowed. Metric weights and other container information should not be visible. d. Have smooth and finished edges. Modifications to the container must be framed to eliminate raw or sharp edges.
Note: Requirement listed are based on the City of Springfield Office of Public Works Central
Business District Parklet Guidelines. See Guidelines for additional information.
Wood Decking
Prohibited Materials1. Wood pallets2. Paint on any street or sidewalk surface3. Carpet
Massie Massie + AssociatesMay 4, 2021
42"
36'
5' 5'
Ramp Diagram
Safety Barrier Recommendations
Sheet 05
2Requirements
Metal Railing
Narrow Planters
Shipping Container Side Wall/Bench
1. Safety Barrier shall be impact resistant2. Barrier shall be a minimum of 42" high from the top of the finished surface of the parklet.3. Openings in railings and/or other barrier materials shall be no greater than 4" wide4. Barriers to be secured in place or heavy enough so they cannot blow into the traffic lane(s). Examples: a. Planters to be a minimum of 100 lbs. when filled b. Railing sections to be secured to each other and anchored to a stationary object(s). Barriers cannot be secured directly to the street pavement.
Note: Requirement listed are based on the City of Springfield Office of Public Works Central
Business District Parklet Guidelines. See Guidelines for additional information.
Prohibited Materials1. Snow fence2. Traffic cones3. Folding traffic barricades4. Chain link fence5. Chain rails6. Unfinished wood
Massie Massie + AssociatesMay 4, 2021
Required Deflectors
Sheet 06
3Requirements
Trough Style Planters
1. Deflectors, used to alert cars and protect parklet visitors, are a common design element throughout the Central Business District. Two specific types should be used at each parklet location.
Type 1
a. Precast concrete planters, 66" long x 18" wide x 30" high, 1,400 lbs. with forklift slots b. Position 3' from the parking lot striping ("T") on each side of the parklet c. Businesses requesting parklets are responsible for planter maintenance and plant installation. Planters and the plants they contain should be well-maintained and kept free of litter and debris.
Type 2
a. Flexible delineators or vertical barricades meeting IDOT Detail 701901-03 (see below)
b. Align with Type 1 deflector, 8' from face of curb
Note: Requirement listed are based on the City of Springfield Office of Public Works Central
Business District Parklet Guidelines. See Guidelines for additional information.
Type 1 Deflector Type 2 Deflector
Type 2 Deflector
Massie Massie + AssociatesMay 4, 2021
Planter Product Sheet - Type 1 Deflector Flexible Delineator Vertical Barricade
Type 2 Deflectors
Site Furnishing Recommendations
Sheet 07
4Requirements
Powder-coated Metal
1. Tables, chairs, and benches to be commercial grade and manufactured for outdoor use.2. Made of safe and durable materials such as metal, finished wood, or sturdy composite or molded plastic materials.3. Umbrellas should be made of canvas or other non-vinyl materials and be properly anchored. Solid colors are recommended.4. Overhead lighting to be provided by Downtown Springfield Inc. Solar powered to eliminate all cords on the pavement that might create tripping hazards.
Commercial Wood Composite Material
Prohibited Materials1. Sofas2. Unfinished wood3. Card tables and folding chairs4. Lightweight plastic furnishings
Umbrella Options
Solar Powered Overhead LightingMassie Massie + Associates
May 4, 2021