Page 1 MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty. 2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally.When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip- ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authori- ties. 5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 8. This unit must be grounded. CAUTION ! 1. For general ventilating use only. Do not use to exhaust hazard- ous or explosive materials and vapors. 2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL. 3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 4. Please read specification label on product for further informa- tion and requirements. QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND SAVE THESE INSTRUCTIONS CLEANING & MAINTENANCE For quiet and efficient operation, long life, and attractive appear- ance - lower or remove grille and vacuum interior of unit with the dusting brush attachment. The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the blower assembly (includes motor and impeller). OPERATION The fan, light, and night light can be operated separately.Use a 3-function wall control. Do not use a dimmer switch to operate the light. See “Connect Wiring” for details. Use of speed controls other than the NuTone Models 78V and 78W may cause a motor humming noise. WARRANTY Installer: Leave this manual with the homeowner. BROAN-NUTONE THREE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of three years from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this three-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSO- RIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to mis- use, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions. The duration of an implied warranty is limited to the three-year period as specified for the express warranty.Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN- NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EX- CLUSIVE REMEDY UNDERTHIS WARRANTY.BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number stated below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date. Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.nutone.com 888-336-3948 Register your product online at: www.nutone.com/register

Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Page 1

MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-JURY TO PERSONS, OBSERVE THE FOLLOWING:1. Usethisunitonlyinthemannerintendedbythemanufacturer.

Ifyouhavequestions,contactthemanufacturerattheaddressortelephonenumberlistedinthewarranty.

2. Beforeservicingorcleaningunit,switchpoweroffatservicepaneland lock theservicedisconnectingmeans topreventpowerfrombeingswitchedonaccidentally.Whentheservicedisconnecting means cannot be locked, securely fasten aprominentwarningdevice,suchasatag,totheservicepanel.

3. Installation work and electrical wiring must be done by aqualified person(s) in accordance with all applicable codesand standards, including fire-rated construction codes andstandards.

4. Sufficientairisneededforpropercombustionandexhaustingof gases through the flue (chimney) of fuel burning equip-ment topreventbackdrafting.Follow theheatingequipmentmanufacturer’sguidelineandsafetystandardssuchasthosepublishedbytheNationalFireProtectionAssociation(NFPA),andtheAmericanSocietyforHeating,RefrigerationandAirConditioningEngineers(ASHRAE),andthelocalcodeauthori-ties.

5. Whencuttingordrilling intowall or ceiling,donotdamageelectricalwiringandotherhiddenutilities.

6. Ductedfansmustalwaysbeventedtotheoutdoors.7. Acceptableforuseoveratuborshowerwhenconnectedto

aGFCI(GroundFaultCircuitInterrupter)-protectedbranchcircuit.

8. Thisunitmustbegrounded.

CAUTION !1. Forgeneralventilatinguseonly.Donotusetoexhausthazard-

ousorexplosivematerialsandvapors.2. This product is designed for installation in ceilings up to a

12/12pitch(45degreeangle).Ductconnectormustpointup.DONOTMOUNTTHISPRODUCTINAWALL.

3. Toavoidmotorbearingdamageandnoisyand/orunbalancedimpellers,keepdrywallspray,constructiondust,etc.offpowerunit.

4. Pleasereadspecificationlabelonproductforfurtherinforma-tionandrequirements.

QTXEN SERIESFAN / LIGHT / NIGHT LIGHTS

READ AND SAVE THESE INSTRUCTIONS

CLEANING & MAINTENANCEForquietandefficientoperation,longlife,andattractiveappear-ance-lowerorremovegrilleandvacuuminteriorofunitwiththedustingbrushattachment.

Themotorispermanentlylubricatedandneverneedsoiling.Ifthemotorbearingsaremakingexcessiveorunusualnoises,replacetheblowerassembly(includesmotorandimpeller).

OPERATIONThefan,light,andnightlightcanbeoperatedseparately.Usea3-functionwallcontrol.Donotuseadimmerswitchtooperatethelight.See“ConnectWiring”fordetails.UseofspeedcontrolsotherthantheNuToneModels78Vand78Wmaycauseamotorhummingnoise.

WARRANTY

Installer: Leave this manual with the homeowner.

BROAN-NUTONETHREEYEARLIMITEDWARRANTYBroan-NuTonewarrantstotheoriginalconsumerpurchaserofitsproductsthatsuchproductswillbefreefromdefectsinmaterialsorworkmanshipforaperiodofthreeyearsfromthedateoforiginalpurchase.THEREARENOOTHERWARRANTIES,EXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTO,IMPLIEDWARRANTIESOFMERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.During this three-yearperiod,Broan-NuTonewill, at itsoption, repair orreplace,withoutcharge,anyproductorpartwhichisfoundtobedefectiveundernormaluseandservice.THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMPSTARTERS,TUBES,HALOGENANDINCANDESCENTBULBS,FUSES,FILTERS,DUCTS,ROOFCAPS,WALLCAPSANDOTHERACCESSO-RIESFORDUCTING.Thiswarrantydoesnotcover(a)normalmaintenanceandserviceor(b)anyproductsorpartswhichhavebeensubjecttomis-use,negligence,accident,impropermaintenanceorrepair(otherthanbyBroan-NuTone),faultyinstallationorinstallationcontrarytorecommendedinstallationinstructions.Thedurationofanimpliedwarrantyislimitedtothethree-yearperiodasspecifiedfortheexpresswarranty.Somestatesdonotallowlimitationonhowlonganimpliedwarrantylasts,sotheabovelimitationmaynotapplytoyou.BROAN-NUTONE’SOBLIGATIONTOREPAIRORREPLACE,ATBROAN-NUTONE’S OPTION, SHALL BETHE PURCHASER’S SOLEAND EX-CLUSIVEREMEDYUNDERTHISWARRANTY.BROAN-NUTONESHALLNOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIALDAMAGESARISING OUT OF OR IN CONNECTIONWITH PRODUCTUSE OR PERFORMANCE. Some states do not allow the exclusion orlimitationofincidentalorconsequentialdamages,sotheabovelimitationmaynotapplytoyou.Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveotherrights,whichvary fromstate tostate.Thiswarrantysupersedesallpriorwarranties.Toqualify forwarrantyservice,youmust(a)notifyBroan-NuToneat theaddressortelephonenumberstatedbelow,(b)givethemodelnumberandpartidentificationand(c)describethenatureofanydefectintheproductorpart.Atthetimeofrequestingwarrantyservice,youmustpresentevidenceoftheoriginalpurchasedate.Broan-NuToneLLC,926W.StateStreet,Hartford,Wisconsin53027www.nutone.com888-336-3948

Register your product online at: www.nutone.com/register

Page 2: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Page 2

MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

TYPICAL INSTALLATIONS

Housing mounted to I-joists.

Housing mounted anywhere be-tween trusses using hanger bars.

PLAN THE INSTALLATION

Theunitwilloperatemostquietlyandefficientlywhenlocatedwheretheshortestpossibleductrunandminimumnumberofelbowswillbeneeded.

Use a roof cap or wall cap that has a built-in damper toreducebackdrafts.

Plantosupplytheunitwithproperlinevoltageandappropri-atepowercable.

Housing mounted anywhere be-tween I-joists using hanger bars.

Housing mounted to joists. Housing mounted anywhere be-tween joists using hanger bars.

Housing mounted anywhere between trusses using hanger bars.

INSTALL HOUSING & DUCT1a. Mount

housing to joist or I-joist.UseaplierstobendhousingTABSoutto900.Holdhousinginplacesothatthehousingtabscontactthebottomofthejoist.Thehousingmountswithfour(4)screwsornails.Screwornailhousingtojoistthroughlowestholesineachmountingflange,thenthroughhighestholes.

SPACER(useformountingtoI-Joist)

I-JOIST

NOTE:MountingtoI-JOIST(shown)requiresuseofSPACERS(included)betweenthehighestholeofeachmountingflangeandtheI-joist.

OR

CookingEquipment

Floor

COOKING AREADo not install above or

inside this area.

45o 45o

NOT FOR USE INA COOKING AREA.

ROOFCAP*

6-IN.ROUNDELBOW(S)*

6-IN.ROUNDDUCT* WALL

CAP**Purchase separately

INSULATION(Canbeplacedaroundandover

fanhousing.)

FANHOUSING

TABS

Page 3: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Page 3

MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

4. Connect electrical wiring. Run120VAChousewiringtoinstallationlocation.Use

properULapprovedconnectortosecurehousewiringtowiringplate.Connectwiresasshowninwiringdiagrams.

CONNECT WIRING

2. Attach damper/duct connector.Snapdamper/ductconnectorontohousing.Makesurecon-nectorisflushwithtopofhousinganddamperflapfallsclosed.

3. Install 6-inch round duct-work.Connect6-inchroundductworktodamper/ductconnector.Runductworktoaroofcaporwallcap.Tapeallductworkcon-nectionstomakethemsecureandairtight.

1b. Mount housing anywhere between trusses, joists, or I-joists using hanger bars.

Slidinghangerbarsareprovidedtoallowforaccurateposi-tioningofhousinganywherebetweenframing.Theycanbeusedonalltypesofframing(I-joist,standardjoist,andtrussconstruction)andspanupto24”.

Attach theMOUNTINGCHANNELS to thehousingusingtheSCREWSsupplied.MakesureTABSface“up”asshown.Usethesetofchannelmountingholes(marked“STD”)tomountthehousingflushwiththebottomofthedrywall.Usetheothersetofholes (notmarked) tomount thehousingflushwiththetopofthedrywall.

HANGERBAR(4)

SCREWS(4)

TAB

ExtendHANGERBARStothewidthoftheframing.

Hold ventilator in place with the hanger bar tabs wrappingaroundtheBOTTOMEDGEOFTHEFRAMING.

NAILventilatortoframingorfastenwithscrews(notprovided)throughHOLESnearnails.

*Toensureanoise-freemount:Securehangerbarstogetherwith SCREWSor use apliers to crimp mounting channelstightlyaroundhangerbars.

HOLEFOROPTIONALSCREWMOUNTING(4)

STD

MOUNTINGCHANNEL(2)

NAIL(4)BOTTOMEDGEOFFRAMING

*SCREW(2)

Page 4: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Page 4

MODELS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

SERVICE PARTS

99044460A

Key No. Part No. Description

1 97016466 Housing 2 97016450 DuctConnector-6” 3 98010102 WiringPlate 4 99170245 Screw,#8-18X.375 5 97018011 WirePanel/HarnessAssembly 6 97017850 BlowerAssembly(QTXEN080FLT) 97017851 BlowerAssembly(QTXEN110FLT) 97016591 BlowerAssembly(QTXEN150FLT) 7 97018272 GrilleAssembly(includeskeynos.8,9&10) 8 99140199 GrilleSpring(2req’d) 9 99111400 Lens 10 99271381 Bulb,GU24,18WFluorescent,(2req’d) 11 99420665 Thumbscrew,#8-18x.375 12 97018014 Spacer(2supplied) 13 QTNHB1 HangerBarKit

Orderservicepartsby“PartNo.”-notby“KeyNo.”

INSTALL GRILLE

5. Finish ceiling. Installceilingmaterial.Cutoutaroundhousing.

6. Attach grille to housing.

Squeezegrillespringsandinsertthemintotabsoneachsideofhous-ing.

8. Remove light lens.

Carefullyin-sertasmallflat-bladescrewdriverbetweengrilleandlens.Prylensout.

7. Push grille against ceiling.

9. Install light bulbs.

Fluores-centbulbssupplied.Purchasea4Wincan-descentnight-lightbulb.Insertbulbsintotheirsockets.Replacelens.

SERVICE NOTEToremoveBlowerAssembly:Unplugmotor.Removethumbscrew(11)frommotorplateflange.FindthesingleTABonthemotorplate(locatednexttothereceptacle).Pushupnearmotorplatetabwhilepushingoutonsideofhousing.Orinsertastraight-bladescrewdriverintoslotinhousing(nexttotab)andtwistscrewdriver.

Replacement parts can be or-dered on our website. Please visit us at www.nutone.com

Page 5: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Página 5

MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, OBSERVE LAS SIGUIENTES PRECAUCIONES:1. Use launidadsólode lamanera indicadaporel fabricante.Si

tienepreguntas,comuníqueseconelfabricanteenladirecciónoelnúmerotelefónicoqueseincluyeenlagarantía.

2.Antesdedarservicioa launidadode limpiarla, interrumpaelsuministroeléctricoenelpaneldeservicioybloqueelosmediosde desconexión del servicio para evitar que la electricidad sereanudeaccidentalmente.Cuandonoseaposiblebloquear losmediosdedesconexióndelservicio,fijefirmementeunaseñaldeadvertencia(talcomounaetiqueta)enunlugarvisibledelpaneldeservicio.

3.Eltrabajodeinstalaciónyelcableadoeléctricodebenestaracargodeunpersonalcapacitadoydebensatisfacertodosloscódigosynormascorrespondientes, incluidos loscódigosynormasdeconstrucciónespecíficossobreproteccióncontraincendios.

4.Senecesitasuficienteaireparaquese lleveacabounacom-bustiónydescargaadecuadasdelosgasesatravésdeltubodehumos(chimenea)delequipoquemadordecombustible,afindeevitarloscontratiros.Sigalasdirectricesylasnormasdeseguridaddelfabricantedelequipodecalentamiento,comolaspublicadasporlaAsociaciónNacionaldeProteccióncontraIncendios(Na-tionalFireProtectionAssociation,NFPA),laSociedadAmericanadeIngenierosdeCalefacción,RefrigeraciónyAireAcondicionado(AmericanSocietyforHeating,RefrigerationandAirConditioningEngineers,ASHRAE)ylasautoridadesdeloscódigoslocales.

5. Al cortar o perforar a través de la pared o del cielo raso, no dañeel cableado eléctrico ni otros servicios ocultos.

6.Losventiladoresconconductosdebensiempreconectarsehaciaelexterior.

7. Estaunidadpuede instalarse sobreuna tinaoducha siemprequeseconecteaunGFCI(interruptoraccionadoporpérdidadeconexiónatierra)enuncircuitodederivaciónprotegido.

8.Estaunidaddebeconectarseatierra.

PRECAUCIÓN !1. Sóloparausarsecomomediodeventilacióngeneral.Noseuse

paradescargarmaterialesnivaporespeligrososoexplosivos.2. Esteproductosediseñaparalainstalaciónentechoshastauna

echadade12/12(ángulode45grados).Conectordeconductordebeseñalarhaciaarriba.NOMONTEESTEPRODUCTOENUNATECHO.

3. Para evitar daños a los cojinetes del motor y rotores ruidosos y/o noequilibrados, mantenga la unidad de accionamiento al resguardode rociados de yeso, polvos de construcción, etc.

4. Léaselaetiquetadeespecificacionesquetieneelproductoparaverinformaciónyrequisitosadicionales.

VENTILADOR/LÁMPARA/LÁMPARAS DE NOCHE SERIE QTXEN

LEA Y CONSERVE ESTAS INSTRUCCIONES

LIMPIEZA Y MANTENIMIENTOParalograrunfuncionamientosilenciosoyeficiente,comotambiénlargavidayunaaparienciaatractiva,bajeoretirelarejillayaspireelinteriordelaunidadconelaccesoriodelcepilloparasacudirpolvo.

Elmotorestápermanentementelubricadoynuncanecesitaráaceite.Siloscojinetesdelmotorestánhaciendoruidoexcesivooinusitado,reemplaceel conjuntodelventilador (incluyeelmotoryel rodetedelventilador).

OPERACIÓNElventilador, la lámparay la lámparadenochepuedenfuncionarseparadamente.Utiliceuncontroldeparedde3funciones.Noutiliceuninterruptorreguladorparafuncionarlaluz.Vealosdetallesenlasección“Conexióneléctrica”.Elusodeloscontrolesdelavelocidadconexcepcióndelosmodelos78Vy78WdeNuTonepuedecausarunruidodeltarareodelmotor.

A la persona que realiza la instalación: Deje este manual con el

dueño de la casa.

GARANTÍAGARANTÍALIMITADADETRESAÑOSDEBROAN-NUTONE

Broan-NuTonegarantizaal consumidor comprador original que susproductosestaránlibresdedefectosencuantoamaterialymanodeobraduranteunperíodode tresañosapartir de la fechade la compraoriginal.NOEXISTENOTRASGARANTÍAS,EXPRESASNIIMPLÍCITAS,INCLUIDAS(PEROSINLIMITARSEA)GARANTÍASIMPLÍCITASDECOMERCIALIZACIÓNOIDONEIDADPARAUNPROPÓSITOPARTICULAR.Duranteesteperíododetresaños,Broan-NuTone,asucriterio,repararáoreem-plazará,sincargoalguno,cualquierpiezaoproductoqueseencuentredefectuosobajocondicionesnormalesdeusoyservicio.LAPRESENTEGARANTÍANOCUBRELOSTUBOSFLUORESCENTESNISUSARRANCADORES,BOMBILLASDEHALÓGENOEINCANDESCENTES,FUSIBLES,FILTROS,CONDUCTOS,TAPONESDETECHOOPAREDESYDEMÁSACCESORIOSPARACONDUCTOS.Estagarantíanocubre(a)man-tenimientooservicionormalesni(b)productosopiezasquesehayansometidoausoinadecuado,negligencia,accidente,mantenimientooreparacióninadecuada(nohechaporBroan-NuTone),instalaciónincorrectaoinstalaciónencontradelasinstruccionesdeinstalaciónrecomendadas.Laduracióndeunagarantíaimplícitaselimitaalperíododetresaños,comoseespecificaparalagarantíaexplícita.Algunosestadosnopermitenlimitarladuracióndeunagarantíaimplícita,demaneraquelaslimitacionesantedichaspodríannoaplicarseausted.LAOBLIGACIÓNDEBROAN-NUTONEDEREPARAROREEMPLAZAR,AOP-CIÓNDEBROAN-NUTONE,SERÁELÚNICOYEXCLUSIVORECURSODELCOMPRADORBAJOESTAGARANTÍA.BROAN-NUTONENOSERÁRESPON-SABLEPORDAÑOS INCIDENTALES,RESULTANTESOESPECIALESQUESURJANDE,OENRELACIÓNCON,ELUSOORENDIMIENTODELPRODUCTO.Algunosestadosnopermitenexcluirolimitardañosincidentalesoresultantes,demaneraqueesposiblequelalimitaciónantedichanoseapliqueensucaso.Estagarantíaledaderechoslegalesespecíficos;ustedpodríatenerotrosderechosquevaríanentreestados.Estagarantíasustituyetodaslasgarantíasanteriores.Para tener derecho al servicio de la garantía, usted debe (a) notificar aBroan-NuTone a la dirección y número de teléfono que aparecen abajo,(b) proporcionar el número de modelo y la identificación de la pieza y(c) describir la naturaleza de cualquier defecto en el producto o pieza. En e l momento de so l i c i ta r e l ser v ic io de la garan t ía , debe presentarelcomprobanteconlafechadelacompraoriginal.Broan-NuToneLLC,926W.StateStreet,Hartford,Wisconsin53027www.nutone.com888-336-3948

Para registrar este producto visite: www.nutone.com/register

Page 6: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Página 6

MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

INSTALACIONES TÍPICAS

PLANIFICACIÓN DE LA INSTALACIÓN

Montaje de la cubierta en viguetas “I”.

Montaje de la cubierta en cualquier parte entre armaduras por medio

de barras de suspensión.

Montaje de la cubierta en cualqui-er parte entre las viguetas “I” por medio de barras de suspensión.

Montaje de cubierta en viguetas. Montaje de la cubierta en cualquier parte entre las viguetas por medio

de barras de suspensión.

Montaje de la cubierta en cualquier parte entre armaduras por medio

de barras de suspensión.

Elventiladorfuncionaráconmáseficienciaymenosruidosiseubicaenunsitiodonderequieraeltramodeconductomáscortoposibleyunmínimonúmerodecodos.

Instaleunatapadetechoodeparedquetengaunreguladordetiroincorporadoafindereducirloscontratiros.

Alimentelaunidadconelvoltajedelíneayelcableeléctricoapropiados.

O BIEN

INSTALE LA CUBIERTA Y EL CONDUCTO1a. Instale la

cubierta en las viguetas o viguetas “I”.

Conunalicate,doblelasLENGÜETASdelacubiertaa90°.Sostengalacubiertaensulugardemaneraquelaslengüetasdelacubiertahagancontactoconlaparteinferiordelavigueta.Paraelmontajedelacubiertaseutilizancuatro(4)tornillosoclavos.Atornilleoclavelacubiertaalaviguetaatravésdelosorificiosmásbajosdecadabridademontaje,yseguidamenteatravésdelosmásaltos.NOTA:ParaelmontajeenlaVIGUETA “I”,talcomoseilustra,serequiereutilizarSEPARADORES(incluidos)entreelorificiomásaltodecadabridademontajeylavigueta“I”.

VIGUETA “I”

SEPARADOR(seusaparaelmontajealavigueta“I”)

LENGÜETAS

Equipopara cocinar

Piso

ÁREA QUE COCINANo instale sobre o dentro

de esta área.

45o 45o

NO PARA ELUSO EN UN

ÁREA QUE COCINA.

CODO REDONDODE 6 PULG. *

CUBIERTA DEVENTILADOR

CONDUCTOREDONDO DE

6 PULG. ** Se compran

por separado

TAPA DE

PARED *

TAPA DETECHO *

AISLAMIENTO(Puede ser colocado

alrededor y sobre de la cubierta del

ventilador.)

Page 7: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Página 7

MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

4. Conecte los cables eléctricos. Extiendaelcableadodelacasade120VCAallugardela

instalación.UtiliceunaconexiónaprobadaporULparaafianzarelcableadodelacasaalaplacadecableado.Conecteloscablestalcomoseilustraenlosdiagramasdecableado.

CONEXIÓN ELÉCTRICA

3. Instale el conducto redondo de 6 pulgadas.Conecteelcon-ductoredondode6pulg.alconec-tordelregulador/conducto.Extiendaelconductohaciaunatapadetechootapadepared.Encintetodaslasconexionesdelosconductosparafijarlasyhacerlasherméticasalaire.

2. Acople el conectador del regulador de tiro/conducto.Conecteapresiónelconectadordelregu-ladordetiro/conduc-toenlacubierta.Asegúresedequeelconectorestéalrasconlapartesuperiordelacubiertayquelaaletadelreguladorcaigacerrada.

1b. Instale la cubierta en cualquier parte entre las armaduras, viguetas o viguetas “I” por medio de barras de suspensión.

Seproporcionanbarrasdesuspensióndeslizantesparafacilitarlacolocaciónadecuadadelacubiertaencualquierparteentrelaestructura.Estasbarrasseadaptanatodaclasedeestructuras(construccionesdeviguetas“I”,viguetasestándaryarmaduras)y seextiendenaunmáximode61cm(24pulg.).

FijelosCANALESDEMONTAJEalacubiertaconlosTORNIL-LOSincluidos.AsegúresedequelasLENGÜETASesténdecarahaciaarriba,talcomosemuestra.Utiliceeljuegodeorificiosdemontajedelcanal(marcadoscomo“STD”)paramontarlacubiertaalrasconlaparteinferiordelatablarroca.Utiliceelotrojuegodeorificios(sinmarca)paramontarlacubiertaalrasconlapartesuperiordelatablarroca.

BARRADESUS-PENSIÓN(4)

TORNILLOS(4)

LENGÜETA

STD

CANALDEMONTAJE(2)

Abra las BARRAS DE SUSPENSIÓN hasta el ancho de laestructura.

SostengaelventiladorensusitioenvolviendolaslengüetasdelabarradesuspensiónalrededordelBORDEINFERIORDELAESTRUCTURA.

CLAVEelventiladora laestructuraosujételocontornillos(noincluidos)atravésdelosORIFICIOSqueestáncercadelosclavos.

*Paralograrunmontajesilencioso:acopleyfijelasbarrasdesuspensiónconTORNILLOS,odobleloscanalesdemontajeconunalicatebienjustosalrededordelasbarrasdesuspensión.

CLAVO(4)BORDEINFERIORDE

LAESTRUCTURA

ORIFICIOPARAMONTAJECONTORNILLOOPCIONAL(4) *TORNILLO(2)

Page 8: Page 1 QTXEN SERIES FAN / LIGHT / NIGHT LIGHTS READ AND ... Installation.pdf · impellers, keep drywall spray, construction dust, etc. off power ... tiene preguntas, comuníquese

Página 8

MODELOS QTXEN080FLT • QTXEN110FLT • QTXEN150FLT

99044460A

PIEZAS DE REPUESTO

Clave n.o Pieza n.o Descripción

1 97016466 2 97016450 3 98010102 4 99170245 5 97018011 6 97017850 97017851 97016591 7 97018272

8 99140199 9 99111400 10 99271381 11 99420665 12 97018014 13 QTNHB1

Alhacerelpedidodeunapiezadeserviciosedebeespecificarelnúmerodelapieza(noelnúmerodelaclave).

INSTALE LA REJILLA

5. Termine el cielo raso. Instaleelmaterialdelcieloraso.Recortealrededordela

cubierta.

6. Acople la rejilla a la cubierta.Aprietelosresortesdelarejillaeinsér-telosenlaslengüetasqueseencuentranacadaladodelacubierta.

7. Empuje la rejilla contra el cielo raso.

8. Saque la lente de la lámpara.Concuidado,inserteundestornilladorplanopequeñoentrelapa-rillaylalentedelámpara.Hagapalancaconeldestornilladorysaquelalente.

9. Instale las bombillas.Seincluyelasbombillasfluorescentes.Compreunabombilladenocheincandescentede4W.Insertelasbombillasasureceptáculos.Vuelvaacolocarlalente.

NOTA DE SERVICIO Para desmontar el conjunto del ventilador: Desenchufe el motor. Saque el tornillo de mariposa (11) de la brida de la placa del motor. Localice la LENGÜETA única de la placa del motor (se encuentra junto al receptáculo). Empuje hacia arriba cerca de la lengüeta de la placa del motor al mismo tiempo que empuja hacia afuera el costado de la cubierta. O bien, introduzca un destornillador de punta recta en la ranura de la cubierta (junto a la lengüeta) y gírelo.

Las piezas de recambio se pueden ahora pedir en nuestro Web site. Visítenos por favor en

www.nutone.com

CubiertaConectordeconductor,6pulg.PlacadecableadoTornillon.o8-18x0.375Conjuntodelpaneldecableado/arnésConjuntodelventilador(QTXEN080FLT)Conjuntodelventilador(QTXEN110FLT)Conjuntodelventilador(QTXEN150FLT)Conjuntodelarejilla(incluyenlaspiezasdelasclavesn.o8,9&10)Resortedelarejilla(serequieren2)LenteBombillafluorescente,GU24,18W(serequieren2)Tornillodemariposan.o8-18x0.375Separador(provisto2)Juegodebarradesuspención