A Packaged Water Heater Ready For Installation MODEL ST ASME U Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining provides superior protection and tank longevity Heavy duty construction withstands demanding commercial/industrial use Packaged System Factory supplied with all steam controls saving time and money during installation All steam operating controls are factory sized and selected to ensure reliable operation Versatile Full range of styles, sizes, and optional features to meet your exact heating needs Applications Schools Office Buildings Prisons Stadiums Hotels Industrial Facilities Nursing Homes Hospitals The Model ST is a fully packaged steam fired storage water heater Model STH Storage Tank Type A Heavy Duty Steam Fired Storage Water Heater The Model ST is a fully packaged steam fired water heater designed to be a reliable and long lasting source for hot water. Each component is carefully selected to ensure performance in even the most demanding application. Whether you are heating potable water in a commercial building or process water in an industrial application, you can select a Hubbell Model ST to do the job. When you specify and install a Hubbell ST model water heater you will have confidence in knowing that the owner will be provided with a quality product that is a long lasting and trouble-free source for hot water. Packaged Steam Fired Water Heater Utilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters

Packaged Steam Fired Water Heater - Hubbell - Hubbell … Model ST is a fully packaged steam fired water heater designed to be a reliable and long lasting source for hot water

  • Upload
    ngocong

  • View
    218

  • Download
    1

Embed Size (px)

Citation preview

A Packaged Water Heater Ready For Installation

MODEL ST

ASME

U

Features■ Reliable� Onlyhighgradematerialsusedin

constructiontoensurelongoperatinglife

� Hydrastonecementliningprovidessuperiorprotectionandtanklongevity

� Heavydutyconstructionwithstandsdemandingcommercial/industrialuse

■ Packaged System� Factorysuppliedwithallsteamcontrols

savingtimeandmoneyduringinstallation� Allsteamoperatingcontrolsarefactory

sizedandselectedtoensurereliableoperation

■ Versatile� Fullrangeofstyles,sizes,andoptional

featurestomeetyourexactheatingneeds

Applications■ Schools■ OfficeBuildings■ Prisons■ Stadiums■ Hotels■ IndustrialFacilities

■ NursingHomes■ Hospitals

The Model ST is a fully packaged steam fired storage water heater

Model STH Storage Tank Type

A Heavy Duty Steam Fired Storage Water HeaterTheModelSTisafullypackagedsteamfiredwaterheater

designedtobeareliableandlonglastingsourceforhotwater.Eachcomponentiscarefullyselectedtoensureperformanceineventhemostdemandingapplication.Whetheryouareheatingpotablewaterinacommercialbuildingorprocesswaterinan

industrialapplication,youcanselectaHubbellModelSTtodothejob.WhenyouspecifyandinstallaHubbellSTmodelwaterheateryouwillhaveconfidenceinknowingthattheownerwillbeprovidedwithaqualityproductthatisalonglastingandtrouble-freesourceforhotwater.

Packaged Steam Fired Water HeaterUtilizes Steam To Heat Domestic Water, Semi-Instantaneous or Storage Type Heaters

scottbarry
Typewritten Text
scottbarry
Typewritten Text
scottbarry
Typewritten Text
scottbarry
Typewritten Text
scottbarry
Typewritten Text
scottbarry
Typewritten Text
scottbarry
Typewritten Text

2

Cement Lined Tanks ProvideLonger Service Life

Unlined TaNks

1. 90/10Copper-NickelA90%Copper10%Nickelalloypressurevesselprovidesstrengthandcorrosionresistance.Typicallyusedinapplicationswithcorrosiveenvironments(saltwater)orincriticalcommercialandindustrialapplicationsrequiringlongtanklife.

2. AlternativeCementFormulationsTomeetthespecificrequirementsofDIWater,ROWater,extendedserviceandorhightemperatureapplications,alternativeformulationsofcementareavailable.Pleaseconsultfactoryforassistance.

3. PhenolicLiningAnepoxycoatingappliedin2coatstoatotalof10-12milsDFT.TypicallyusedinprocessapplicationsusinglowconductivityDIdistilledorfoodgradewater.

4. GalvanizingThesteelpressurevesselispickledandhotdippedinmoltenzinctocreateabarrierwhichinternallyandexternallyprotectsasteelvesselforcoldandhotwaterstorage.

An Unlinedtankdoesnotrequirealiningbecausethepressurevesselitself isconstructedfrommaterialwhichisimpervioustothecorrosiveeffectsofhotwater.Thistypeoftankwillprovideasignificantlylongerservicelifethanalllinedsteeltanks,butisinitiallymorecostly.

2. StainlessSteelStainlesssteel(Specify:Type304,316,or316L)iswellsuitedforindustrialandhighpurityapplicationsrequiringacorrosionresistanttankwithminimalleachingofimpuritiesintothewater.Wellsuitedforprocess,RO,andDIwatersystemsinthepharmaceutical,foodandelectronicindustries.

Linings Available For A Steel Tank

AspeciallyformulatedHydrastonecementappliedtoaminimumof5⁄8"thicknessonallsurfaces.Thecementliningcovers100%ofallinteriorsurfacesandis125timesthickerthanglasslining.Duetothethicknessandguaranteedcoverageofcementliningthereisnoneedforasacrificialanode.Anextremelydurableandlonglastingliningsuitableforhotandcoldpotablewaterstorageinavarietyofcommercialandindustrialapplications.

1. CementLining

Q ?Failureofatank'sprotectiveliningallowswatertocomeintodirectcontactwiththesteeltankcausingittocorrodeandleak.

Therefore,thetypeofprotectiveliningisthesinglemostimportantfeaturewhendeterminingthequalityofanywaterheater.Theabilityofaliningtoprotectthesteeltankisprimarilybaseduponitsthicknessandcompletecoverageofallsteelsurfaces.

Whatisthemostcommonreasonwhyawaterheaterfails?

A !

3

Model ST Storage Type Standard Equipment

Model ST Optional Equipment

Vessel Construction1. Allweldedcarbonsteelvesseldesignedand

builtinstrictaccordancewiththeASMECodeSectionVIIIandstamped,certifiedandregisteredwiththeNationalBoardofBoilerandPressureVesselInspectors

2. Allinternaltanksurfacesarelinedwithaminimumof5⁄8"thickHydrastonecementforsuperiorprotectionandtanklongevity

3. Designedfor125psiworkingpressureandhydrostaticallytested

Steam Heating Coil1. Ahighqualityfactoryinstalled2passU-Tube

heatingcoilconstructedfrom18gauge¾"O.D.singlewallcoppertubingdesignedforamaximumworkingpressureof150psi

2. Allwettedpartsarenon-ferrousformaximumlongevity

3. HeavydutyfabricatedsteelheadwiththreadedNPTsteamandcondensateconnections

4. Copperlinedtubesheet5. PleaseReferenceHUBBELLbrochure“Heating

Coils”fordetailedheatingcoilconstructionfeaturesSteam Operating Controls

1. Steamoperatingcontrolsarefactoryselected,sized,pipedandtestedtoensurereliableoperation

2. Allsteamcomponentsarefactoryplumbedwithschedule40blackironpipeandreadyforsteamandcondensateconnections

3. Highqualitycastironpilotoperatedsteamcontrolvalvemodulatestheflowofsteamthroughtheheatingcoiltoprovideaccuratewatertemperaturecontrol

4. CastironYstrainerwith20Meshscreenprotectsthesteamcontrolsandcoilfromdirtanddebrisinthesteamsupply

5. Thermostaticdriptrapremovescondensatefromthesteamsupplyline

6. Heavydutycastironfloatandthermostaticmaincondensatetrapforoptimumefficiency

7. Brassvacuumbreakeranddialsteampressuregauge

General1. Heavyduty3"thickfiberglassinsulation

covers100%ofthepressurevesselformaximumoperatingefficiencyandminimalstand-byheatloss

2. Heavygaugepaintedgalvanizedsteelprotectiveouterjacket

3. Heavydutyintegrallyweldedsteelsupportsforfloormounting

4. Fullfive(5)yearNonPro-Ratedtankwarrantyandaone(1)yearsteamcomponentwarranty

5. ASMEratedcombinationT&Preliefvalvesetatthetankworkingpressureand210oF

NOTE:Otheroptionalfeaturesareavailable,pleaseconsultfactoryifrequired.

Steam Heating Coil4. Doublewalltubingwithaleakdetectionport5. Alternatetubingmaterialpleasespecify:

(StainlessSteel,90/10Copper-Nickel,Admiralty,Other)

6. Fabricatedsteamheadconstructedfrom:(StainlessSteel,CopperAlloy,Other)

General7. SkidmountingonheavydutyallweldedIBeam8. Type304stainlesssteelprotectivejacket,please

specifyifpainted9. Manway12"x16"orInspectionOpening3"NPT

Vessel1. Alternateprotectivelining:

Phenolicepoxyresin,Flamespraycopper,Hotdipgalvanizing,other

2. Alternatevesselconstruction:StainlessSteelType304or316L,90/10Copper-Nickel,other

3. Alternateworkingpressure:Pleasespecify

Operating Controls10. Steamcontrolscanbefactoryselectedandsized,

butshippedlooseforinthefieldinstallationbyothers

11. Varioussteamcontrolvalvesareavailabletomeetthespecificneedsofyourapplication,pleasespecify:Self-operatedtype,pneumaticoperated,electronicoperated,separatepressurereducingpilottype

12. Singlesolenoidsafetysystemclosesthesteamsupplytothecontrolvalveshouldthewatertemperatureinthetankreachthehi-limitsetpoint.Requires120volt5ampelectricalservice

13. Adoublesolenoidsafetysystemdumpsoverheatedwaterinthestoragetanktodraininadditiontoclosingthesteamsupplytothecontrolvalve.Requires120volt5ampelectricalservice

14. Intra-tankcirculationpumppackagecontinuouslycirculateswaterwithinthetankinordertoreducestratification.AllbronzefractionalHPpump

15. Anticipatorcontrolsystemforcesincomingcoldwateroverthecontrolvalvesensingbulbinordertobeginheatingwaterimmediately

16. Dialwaterthermometerandpressuregaugefactoryinstalledinthetank

17. Factorywrappedandbaffledsteamcoilwithintegralpumppackage

Please note: optional equipment may impact overall dimensions and weight. Please request submittal drawing from factory.

4

Note:Alldimensionsareapproximateandsubjecttochange.Pleasereferencethesubmittaldrawingforactualdimensions.Thetankselectionsaboveareshownforconvenience.Afullselectionofstoragecapacitiesisavailablebyenteringthedesiredcapacityintothemodelnumber.* 80,120and150gallontanksdonotcomeequippedwithamanway.Pleaseconsultfactoryifdesiredonthesesizes.

Overall Dimensions, Models ST and STH

ActualStorageCapacity(Gallons)

OverallDimensions(Inches) StorageTank

NominalStorageCapacity(Gallons)

InletOutletSizing(NPT)

Approx.ShippingWeight(Lbs.)

Vertical HorizontalDiameter

“A”Height“B”

Length“C”

Width“D”

Height“E”

DiameterxLength

80* 26 65 60 26 32 22 x 54 90 1.5 700

120* 28 75 68 28 34 24 x 64 140 1.5 900

150* 30 79 72 30 36 26 x 68 170 1.5 1100

175 36 73 67 36 44 30 x 63 195 1.5 1500

200 36 82 76 36 44 30 x 72 220 1.5 1700

225 36 89 83 36 44 30 x 79 245 1.5 1750

250 42 74 68 42 50 36 x 64 285 1.5 1850

275 42 80 74 42 50 36 x 70 310 1.5 2000

300 42 88 82 42 50 36 x 78 345 1.5 2180

325 42 92 86 42 50 36 x 82 360 1.5 2300

350 42 94 88 42 50 36 x 84 370 1.5 2500

375 48 81 75 48 56 42 x 71 425 1.5 2600

400 48 85 79 48 56 42 x 75 450 1.5 2700

425 48 88 82 48 56 42 x 78 470 1.5 2900

450 48 93 87 48 56 42 x 83 500 1.5 3000

475 54 79 73 54 62 48 x 69 540 2 3100

500 54 82 76 54 62 48 x 72 565 2 3225

525 54 85 79 54 62 48 x 75 590 2 3350

550 54 89 83 54 62 48 x 79 620 2 3400

575 54 93 87 54 62 48 x 83 650 2 3500

600 54 95 89 54 62 48 x 85 665 2 3650

700 54 107 101 54 62 48 x 97 755 2 4000

800 54 119 113 54 62 48 x 109 850 2 4300

900 54 132 126 54 62 48 x 122 940 2 4800

1000 54 145 139 54 62 48 x 135 1060 2 5200

1250 60 149 143 60 68 54 x 139 1380 2 5600

1500 60 174 168 60 68 54 x 164 1625 2 6000

1750 66 168 162 66 74 60 x 158 1935 3 7400

2000 66 185 179 66 74 60 x 175 2145 3 8100

2500 78 169 163 78 86 72 x 159 2800 3 8200

3000 78 197 191 78 86 72 x 187 3300 3 8300

3500 90 174 168 90 98 84 x 164 3935 6FLG. 8900

4000 90 195 189 90 98 84 x 185 4440 6FLG. 9800

4500 N/A N/A 168 102 108 96 x 160 5015 6FLG. 10700

5000 N/A N/A 183 102 108 96 x 175 5485 6FLG. 11600

5

Model ST (Vertical)

SideView

FrontView

WithdrawalSpace

HotWaterOutlet

LiftingLug

T&PReliefValve

C

E

D

HeatingCoil

28"

ColdWaterInlet

PressureVessel

Insulation

ProtectiveJacket

Drain

Manway

SideView FrontView

A

ProtectiveJacket

PressureVessel

12"x16"Manway

WithdrawalSpace

HeatingCoil

28"

CombinationColdWaterInletandDrain

6"

B

HotWaterOutlet

T&PReliefValve 4"

Insulation

Outline Dimensions

Convection Model Shown

Model STH (Horizontal)Convection Model Shown

LiftingLug

Supports

SkidBase(optional)

Standard:SaddleOptional:Skids

6

Steam Component General ConfigurationThesteamcontrolvalvemaintainsaccuratewatertemperatureinasteamfiredwaterheaterbyregulatingtheflowofsteamthroughtheheatingcoil.

There are four types of steam control valves available for use on a steam fired storage water heater.

Self Operating

Thevalvedesignincludesabulbandcapillaryassemblychargedwithathermallyresponsivevapor.Theexpansion/contractionofthevaporactsuponthevalvebellowsinordertocontroltheflowofsteamthroughthevalve.Noexternalpowersourceisrequiredforoperation.

Pneumatically Operated

Inthisconfigurationthebuildingairsupplyfeedsafactoryinstalledtemperaturecontrollerwhichoperatesthesteamcontrolvalve.Thetemperaturecontrollersendsapreciseairsignaltothesteamcontrolvalvewhichadjuststheflowofsteamintotheheatingcoil.Thetemperaturecontrollerisfullyadjustablefrom50-250oFandrequires20psiairatamaximumconsumptionof0.5SCFM.

Pilot OperatedApilotoperatedcontrolvalveisthemostwidelyusedtypeofvalveforstandardwaterheatingapplications.Inthistypeofvalve,atemperaturepilotdeviceutilizessteamtooperatethemainvalve.Noexternalpowersourceisrequiredotherthansteam.Thisisahighlydependabletemperaturecontrolsystemwhichissuitableformostcommercialandindustrialapplications.Asanoption,thisvalvemayincludeapressurereducingpilotwhichlimitsthesteampressuretoapredeterminedmaximum.

Electronic OperatedThiscontrolvalveissimilartoapneumaticallyoperatedsystem,exceptinthiscasethetemperaturecontrollerisaPIDdigitaldisplayelectronictemperaturecontrollerwhichoutputsa4-20mAsignaltoacompactmotormountedonthesteamcontrolvalveinordertoproportionallycontroltheflowofsteamtotheheatingcoil.ThetemperaturecontrollerdisplayssetpointaswellasactualwatertemperatureandisavailablewithanRS485communicationsportforremotecontrol.

F&TMainCondensateTrap

AdjustableTemperaturePilot

SteamInlet

YStrainer

CondensateOutlet

SteamControlValve

ThermostaticDripTrap

Tosensingbulbintank

Pneumaticorelectroniccontroller(ifrequired)

SteamPressureGauge

VacuumBreaker

SteamCoil

YStrainer

Models ST and STH Number Designation

opTioN NoTe

Anyandalloptionalequipmentforawaterheatermustbecalledoutinthewrittenspecifications.Amodelnumberinandofitselfdoesnotreflectanyoptionalequipmentselected.

Example: ST600SL - 1250A vertically installed 600 gallon steam fired water heater with a cement lined steel storage tank rated to heat 1250 GPH at a 100oF temperature rise.

■Step2

StorageCapacity:80-5000Gallons

■Step1

Model:ST= Vertical STH = Horizontal

■Step4

RecoveryRating:InGPHat100oF∆T

■Step5

CoilType:S=SingleWallD=DoubleWall

■ Step 3Vessel Type:SL = Cement Lined SteelGL = Phenolic Lined SteelM = Galvanized SteelCN = Solid 90/10 Copper Nickel SS = Solid Stainless Steel(specify Type 304 or 316L)

JOBNAME

REPRESENTATIVE

ENGINEER

CONTRACTOR

Master Specification: Model ST

GENERALProvideaquantityof packagedtypesteamfiredstoragewaterheater(s)ModelNo.asmanufacturedbyHUBBELLElectricHeaterCo.,Stratford,CT.Thepressurevesselshallbemountedonstructuralsupportsandbesuitablyinsulated,jacketed,paintedandprovidedwithliftinglugs.Theentireunitistobepackagedreadyforserviceconnections.

PRESSURE VESSELThepressurevesselshallbeallweldedconstructionandASMECodeSectionVIIIstampedforaworkingpressureof125psi( OptionalSpecification: psi)andcontainaminimumof gallonsofstorage.ThestoragevesselshallbecarbonsteelandlinedwithseamlessHydrastonecementtoaminimumthicknessof5⁄8"on100%ofallinteriortanksurfaces( OptionalSpecifications:Phenoliclinedsteeltank,galvanizedsteeltank,solidType304or316Lstainlesssteeltank,solid90/10Copper-nickeltank).Thepressurevesselistobeinsulatedwith3"thickenergyconservationfiberglassblanketinsulationandenclosedinaheavygaugegalvanizedsteelmetaljacketfinishedingrayhammertoneenamel.ThevesselshallbeprotectedbyanASMEapprovedautomaticreseatingcombinationtemperatureandpressurereliefvalvesetatthetankworkingpressureand210oF.

HEATING SECTIONThe heatingcoilshallberatedtoheat GPHfrom oFto oFwhensuppliedwith PSIofsteamtothecontrolvalveandconsume lbs/hoursteam.Thesinglewall( OptionalSpecification:doublewall)heatingcoilshallbeconstructedfrom¾"O.D.copper( OptionalSpecifications:90/10Copper-nickel,admiralty,stainlesssteel)tubeswithallnon-ferrouswettedpartsandfabricatedsteelhead( OptionalSpecification:Fabricatedstainlesssteelhead,fabricatedcopper-alloyhead).

CONTROLSThewaterheatershall(shallnot)besuppliedwithsteamoperatingcontrols.Acastironpilotoperated( Optional Specifications: Pneumatic,selfoperating,electronic)typesteamcontrolvalveshallregulatetheflowofsteamtotheheatingcoilinordertocontrolwatertemperature.Athermostaticdriptrap,mainF&Tcondensatetrap,Ystrainers,vacuumbreakerandsteampressuregaugeshallbefactorysizedandpipedwiththesteamcontrolvalve.

Inaddition,thewaterheatermaybesuppliedwiththefollowingoptionalfeatures:

Option Domesticwaterdialtemperatureandpressuregaugeshallbefactoryinstalled.

Option Thewaterheatershallbeequippedwithafactorypackagedintra-tankcirculatortoconstantlycirculatewaterwithinthetanktoreducestratification.

Option Theheatingcoilshallbewrappedandbaffledandpipedwithanintegralpumppackagetoforcecirculatewaterovertheheatingcoilinordertoreducethecoilsize.

Option Singlesolenoidsafetysystemtoclosethesteamsupplytotheheatingcoilshouldthewatertemperatureinthetankreachthehi-limitsetpoint.Requires5Amp,120Voltservice.

Option Doublesolenoidsafetysystemdumpsoverheatedwaterinthestoragetanktodraininadditiontoclosingthesteamsupplytothecontrolvalve.Requires5Amp,120Voltservice.

WARRANTYHUBBELLshallwarrantyallcomponentsagainstdefectsinworkmanshipandmaterialforaperiodofone(1)yearfromdateofstart-upandthepressurevesselforafullfive(5)yearsNonPro-Rated( OptionalSpecification:fullten(10)yearsNonPro-Rated)fromdateofstart-up,providedthattheunitisstartedwithinthree(3)monthsofdateofshipmentandinstalledandoperatedwithinthescopeofthetankdesignandoperatingcapability.Eachwaterheatershallbeshippedwithacompletesetofinstallationandoperatinginstructionsincludingasparepartslistandapproveddrawing.

The Electric Heater Company ■ P.O. Box 288 ■ Stratford, CT 06615-0288 ■ Phone: 203-378-2659 ■ Fax: [email protected] ■ www.hubbellheaters.com

ISO 9001:2008 ISO

Committed to continuous improvement...Continuing research results in product improvement; therefore specifications are subject to

change without notice. For the most updated information, consult the factory directly.

 Made in the U.S.A.

7Rev A