    Subject Engine type Ref. Date Document No. DLC Issue Page

    Cyl. out. HT temp. sensor ZA40S WIT-S 27.03.07 P- ZA40S.0013.GB 506 01 1/2

    Wrtsil Italia SpA Bagnoli della Rosandra, 334 Telephone : +39 040 319 5000Services

    34018 San Dorligo Della Valle (TS) ITALY

    Fax : +39 040 319 5647

    pm ob m oq

    klqf`b

    Cylinder outlet cooling water temperature

    sensor

    1 Background

    The purpose of this spare part notice is to assist you in informing about the new versionof the sensors formonitoring the cylinder outlet cooling water temperature and which parts have to be ordered in order to install iton the Sulzer ZA40S engine. The new sensor replaces the old one (see warning on chapter 3); the old one

    will not be available in the future anymore.

    1.1 Introduction

    In order to improve the quality and reliability of the temperature sensor (PT 100) installed on the HTcooling water cylinder output pipe, the old NORIS PT 100 sensor (figure 1) has been replaced witha new type of sensor as showed in the figure 2:

    Figure 1: old sensor Figure 2: new sensor

    The comparison between the 2 sensors evidences the following characteristics:

    Working limit temperature increases from 120 to 220C.

    Working pressure increases from 10 to 60 bars.

    Sensor is flying-lead. The FAST-ON connectors on the sensor have been eliminated.

    Crimp pins type connector replaces the soldered type.

    The sensors will be supplied complete with cable and connector.

  • 8/21/2019 P-Zz

    2/2

    Wrtsil Italy, Services

    Subject Engine type Ref. Date Document No. DLC Issue Page

    Cyl. out. HT temp. sensor ZA40S WIT-S 27.03.07 P- ZA40S.0013.GB 506 01 2/2

    Wrtsil Italia SpA Bagnoli della Rosandra, 334 Telephone : +39 040 319 5000Services

    34018 San Dorligo Della Valle (TS) ITALY

    Fax : +39 040 319 5647

    pm ob m oq

    klqf`b

    2 Application

    This spare part notice concerns Sulzer ZA40S engines where the sensors for monitoring the cylinder coolingwater outlet temperature (coding from 16T22A1 to 16T22A18) are installed.

    3 Note

    Warning: The old sensor pocket is not compatible with the new sensor. For this reason wheneverthe new sensor is installed for the first time the new pocket has to be installed as well.

    4 Parts needed

    To order the sensor kit or a separated spare part refer to following table 1:

    Table 1: spare part code

    Spare part number E.P.N. Description Quantity

    KS 93190 0001 Sensor+Pocket+Cable +Connector 1

    16T22A1 16T22A18 0002 Sensor+Cable+Connector 1

    KS 93191 0001 Pocket 1

    5 Distribution

    Wrtsil Service Network

    Owners of engines concerned

    6 Liability

    NO LIABILITY WHETHER DIRECT, INDIRECT, SPECIAL INCIDENTAL OR CONSEQUENTIAL, IS

    ASSUMED WITH RESPECT TO THE INFORMATION CONTAINED HEREIN. THIS PUBLICATION ISCONFIDENTIAL AND INTENDED FOR INFORMATION PURPOSES ONLY.

    7 Validity

    This general instruction is valid until further notice.