Upload
others
View
7
Download
0
Embed Size (px)
Citation preview
PRODUCT LINE-UPMMS & Structured Cabling Solutions
FIBER OPTICS
NETWORK INFRASTRUCTURE
INSTALLATION CABLES
EQUIPMENT RACKS STRUCTUREDMMS &
CABLINGSOLUTIONS
01ODFDSMW-In Singlemode Indoor FTTH Fiber Drop Cable
ODFDSMB-Out Singmode Outdoor FTTH Fiber Drop Cable
ODGJPFJH Series Multicore Distribution Indoor Fiber Cable
ODGYXTW Series Unitube Outdoor 2-96 Core Fiber Cable
ODGYTS Series 4-144 Cores Corrugated Steel Tape ArmouredPE-UV Black Outdoor Fiber Optic Cable
ODFPS Heat Shrinkable Fiber Splice Protection Sleeve
ODFConSCSM Fiber Field Installable Connector
ODCP Series A Variety Type of Fiber Optic Connector / Coupler
ODPT Series A Variety Type of Fiber Optic Pigtails
ODPC Series A Variety Type of Fiber Optic Patchcords
ODPLC Series 1x4-64 Optical Fiber PLC Splitter
ODRPT Series Multi Core Rainbow Color Fiber Pigtails
IP67 Waterproof Optical Fiber Patchcord
ODTray Indoor Series Fiber Optic Splice Tray
ODFWS 86 x 86mm Fiber Wall Socket - Dual Fiber
ODWMOP0404SC 4-Port FTTH Fiber Termination Box with4pcs SC Adapters
ODWMOP0808SC 8-Port FTTH Fiber Termination Box with8pcs SC Adapters
ODWMOP1616SC 16-Port FTTH Fiber Termination Box with16pcs SC Adapters
ODWMOP2424SC 24-Port FTTH Fiber Termination Box with24pcs SC Adapters
ODWMOP2412LC Outdoor ABS Fiber Wall Mount Enclosurewith Splicing Tray & Adapters
ODWMOP4848SC 48-Port FTTH Fiber Termination Box with48pcs SC Adapters
ODWMB Series Fiber Wall Mount Metal Enclosure & Adapters
ODOM Series Outdoor Metal Termination Box with SplicingTray & Adapters
GPX82-11 Mini Cold-rolled Steel Distribution Frame
ODTray Outdoor Series Fiber Termination Box with SplicingTray
ODOP Series Fiber Outdoor PBC Box with Splicing Tray &LC Adapters
ODRMB Series Fiber Rack Mount Patch Panel with Adapters
ODDRM Series Fiber Drawer Rack Mount Patch Panel withAdapters
OD MTP/MPO Fiber High Density Patch Panel
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
FIBER OPTICS 02OD5000 Series 24AWG CAT5E UTP Network Cable
OD6000 UTP Series 23AWG CAT6 UTP Network Cable
OD6823F 23AWG CAT6 FTP Network Cable
OD6823PE 23AWG CAT6 UTP Outdoor PE Network Cable
OD6023J CAT6 Jelly-filled Outdoor UTP Network Cable
OD6123L CAT6 Stranded Fire Resistance Elevator S/FTPNetwork Cable
ODPC Series Stranded Network Patchcord
ODFP Series Classic Multi Gang Faceplate (White)
ODFPI Series 86 x 86m Faceplate Frame
ODI Series Snap-In Network & Fiber Module
ODKJ Series RJ45 Network Keystone Jack
ODRB Series RJ45 Network Connector Rubber Boots
ODRJ Series RJ45 Network Modular Plug 8-Pin Connector
ODPP Series 24-Port Full Loaded UTP Network Patch Panels
ODCM1UM 1U 19” Horizontal Cable Management
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
NETWORK INFRASTRUCTURE
03ODRG5981 20AWG RG59 75Ω Coaxial Cable
ODRG5973F 22AWG RG59 75Ω Stranded Coaxial Cable
ODRG6102 18AWG RG6 75Ω Coaxial Cable
ODRG6102PE 18AWG RG6 75Ω Outdoor Coaxial Cable
ODRG1116 14AWG RG11 75Ω Coaxial Cable
OD4702TC 4 Core 7/0.2mm Tinned Copper Alarm Cable
ODTF2315 2 Core 23/0.16 Twin Flat Power Cable
ODRS4224 24AWG Multi Conductor EIA-485 Cable
50
51
52
53
54
55
56
57
INSTALLATION CABLES
04GPX82-10 Large Capacity Cold-rolled Steel Distributor Frame
PG-WM Series Wall Mount Distribution Frame
P-WM Series Wall Mount Distribution Frame
PG-FS Series Floor Stand Distribution Frame
PG-TR Series Trunking Rack Distribution Frame
59
60
61
62
63
EQUIPMENT & RACKS
CONTENTS
FIBER OPTICS01
Optical Charateristics
Cladding Diameter µm
%
µm
µm
µm
dB/km
dB
125 ± 0.7
Cladding Non-Circularity
Core Connentricity Error
Mode Cutoff Wavelength
$WWHQXDWLRQ�&RHIˉFLHQWV
Macro Bending Loss
< 1.0
< 0.5
< 1260
1310nm: (< 0.4)1510nm: (< 0.3)
10 turns, 30mm diameter (< 0.25)1 turn, 20mm diameter (< 0.75)
Mode Filed Diameter 1310nm: (8.6 ~ 9.5 ± 0.4)
Sheath Feature Of Optical Fiber Cable
Sheath tensile Strength before thermal aging Mpa
%
%
%
%
> 15
The change rate of sheath tensile strengthbefore and after thermal aging
Sheath break elongation before thermal aging
The change rate of sheath break elongationbefore and after thermal aging
< 10
> 170
< 20
Sheath break elongation after thermal aging > 150
LSZH Outer Jacket
FRP Strength Member
Optical Fiber
FTTH indoor drop cable is constructed with two single modeˉEHU��7KH�FDEOH�LV�SURWHFWHG�E\�D�GLHOHFWULF�VWUHQJWK�PHPEHUPDGH�RI�ˉEHUJODVV�UHLQIRUFHG�SODVWLF��)53��DQG�D�/6=+�RXWHUjacket. Ideal for use in FTTH & FTTx applications between thebuilding’s main telecommunications room and the apartmentRU�RIˉFH�FRQVROLGDWLRQ�SRLQW�
Physical Characteristics
Optical Fiber 2 core
Color of Buffer 1-Blue / 1-Yellow
Core Diameter 250 ± 15µm
Mode Singlemode
Strength Member KFRP / FRP
Diameter Ø 0.6 / 0.52 ± 0.05mm
Sheath LSZH
Nominal Thickness Minimum 0.4mm
Cable Construction
Dimension Max: 3.0×2.0mm ± 0.2mm
Approx. 8kg/kmWeight
Physical Characteristics
Temperature Range -40°C ~ +60°C
Fire Performace IEC 60332-1, IEC 60754-2, IEC 61034
Available Options
ODFD002SMW-In 6LQJOHPRGH�LQGRRU�)77+�ˉEHU�GURS�FDEOH SM, indoor, 2 Cores
ODFD004SMW-In 6LQJOHPRGH�LQGRRU�)77+�ˉEHU�GURS�FDEOH SM, indoor, 4 Cores
ODFD006SMW-In 6LQJOHPRGH�LQGRRU�)77+�ˉEHU�GURS�FDEOH SM, indoor, 6 Cores
4
ODFDSMW-InSinglemode Indoor FTTH Drop Cable
Description
• Robust and lightweightȧ��&RORXU�FRGHG�ˉEHUV�IRU�HDV\�LGHQWLˉFDWLRQ• LSZH jacket for internal use
Features
FIBER OPTICS
LSZH Outer Jacket
FRP Strength Member
Optical Fiber
Steel Wire
Optical Charateristics
Cladding Diameter µm
%
µm
µm
µm
dB/km
dB
125 ± 0.7
Cladding Non-Circularity
Core Connentricity Error
Mode Cutoff Wavelength
$WWHQXDWLRQ�&RHIˉFLHQWV
Macro Bending Loss
< 1.0
< 0.5
< 1260
1310nm: (< 0.4)1510nm: (< 0.3)
10 turns, 30mm diameter (< 0.25)1 turn, 20mm diameter (< 0.75)
Mode Filed Diameter 1310nm: (8.6 ~ 9.5 ± 0.4)
Physical Characteristics
Core Diameter 250 ± 15µm
Mode Singlemode
Strength Member KFRP / FRP
Diameter Ø 0.6 / 0.52 ± 0.05mm
Strength Member 2 Steel Wire
Diameter Ø 0.2 ± 0.05mm
Sheath LSZH
Nominal Thickness Minimum 0.4mm
Cable Construction
Dimension Max: 5.3×2.0mm ± 0.2mm
Approx. 20kg/kmWeight
5
ODFDSMB-OutSinglemode Outdoor FTTH Drop Cable
FTTH outdoor drop cable is constructed with two singlePRGH�ˉEHU��7KH�FDEOH�LV�SURWHFWHG�E\�D�GLHOHFWULF�VWUHQJWKPHPEHU�PDGH�RI�ˉEHUJODVV�UHLQIRUFHG�SODVWLF��)53����VWHHOwire and a LSZH outer jacket.Designed for outdoor installation the cable is well suitedfor connections between the dome closure and smalldwelling unit / warehouse and independent villas.
Description
• Robust and lightweightȧ��&RORXU�FRGHG�ˉEHUV�IRU�HDV\�LGHQWLˉFDWLRQ• LSZH jacket for internal use• Steel wire support`
Features
Sheath Feature Of Optical Fiber Cable
Sheath tensile Strength before thermal aging Mpa
%
%
%
%
> 15
The change rate of sheath tensile strengthbefore and after thermal aging
Sheath break elongation before thermal aging
The change rate of sheath break elongationbefore and after thermal aging
< 10
> 170
< 20
Sheath break elongation after thermal aging > 150
Physical Characteristics
Temperature Range -40°C ~ +60°C
Fire Performace IEC 60332-1, IEC 60754-2, IEC 61034
FIBER OPTICS
Available Options
ODFD002SMB-Out ��FRUHV�6LQJOHPRGH�RXWGRRU�)77+�ˉEHU�GURS�FDEOH SM, outdoor, 2 Cores
ODFD004SMB-Out ��FRUHV�6LQJOHPRGH�RXWGRRU�)77+�ˉEHU�GURS�FDEOH SM, outdoor, 4 Cores
ODGJPFJH SeriesMulti-Core Distribution Indoor Fiber Optic Cable
Ordering Information
Fiber Type
Features•••••
Excellent mechanical and environmental properties([FHOOHQW�ˊDPH�UHWDUGDQW�SHUIRUPDQFH([FHOOHQW�PHFKDQLFDO�SHUIRUPDQFH�RI�WKH�FDEOH�VKHDWK6RIW��ˊH[LEOH��HDV\�IRU�VSOLFLQJ&RPSO\�ZLWK�VWDQGDUG�<'�7������������
Applications••
•
8VHG�IRU�LQGRRU�FDEOLQJ��HVSHFLDOO\�XVHG�DV�GLVWULEXWLRQ�FDEOH8VHG�DV�WKH�LQWHUFRQQHFWLRQV�EHWZHHQ�FRPPXQLFDWLRQ�HTXLSPHQWV�RU�WKH�LQWHUFRQQHFWLRQV�IRU�WHOHFRPPXQLFDWLRQ�FRQWURO�URRPV�RUGLVWULEXWLRQ�IUDPHV�8VHG�DV�SLJWDLOV�DQG�MXPSHUV
Sheath
$UDPLG�<DUQ
7LJKW�EXIIHUHG�)LEHU
6SHFLˉFDWLRQV
Cable cores Overall diameterof cable (mm)
Cable weight(kg/km)
Minimum bending radius Tensile (N) Crush (N/100m)
Static Dynamic Short term Long term Short term Long term
� ����s��� �� �� ��� ��� ����
6 ����s��� �� ��� ��� ��� ����
��� ��� ��� ����
��� ��� ��� ����
��� ��� ��� ����
� ����s��� ��
�� ����s��� ����' ��'
�� ����s��� ��
�� ����s��� �� ��� ��� ��� ����
�� �����s��� ��� ��� ���� ��� ����
Product code Core Quantity Fiber Type
2'*-3)-+ XXX
���������
���
���
�
2 Cores4 Cores6 Cores
48 Cores
XX
SM0�0�0�0�
�����
Singlemode G652D, 9µmOM1, 62.5µmOM2, 50µmOM3, 50µmOM4, 50µm
~
Sheath
X
L��
N/ALSZH
ExampleODGJPFJH006SM� �*-3)-+�VHULHV�LQGRRU�VLQJOHPRGH��wP�ZLWK���FRUHV�ˉEHU�RSWLF�FDEOH�ODGJPFJH012M3L� �*-3)-+�VHULHV�LQGRRU�PXOWLPRGH�20����wP�����FRUHV�ˉEHU�RSWLF�FDEOH�ZLWK�/6=+�MDFNHW�
FIBER OPTICS
6
7
FIBER OPTICS
ODGYXTW SeriesUnitube Outdoor 2-96 Cores Fiber Optic Cable
Features••••••••
Good mechanical and temperature performance High strength loose tube that is hydrolysis resistant6SHFLDO�WXEH�ˉOOLQJ�FRPSRXQG�HQVXUH�D�FULWLFDO�SURWHFWLRQ�RI�ˉEHU&UXVK�UHVLVWDQFH�DQG�ˊH[LELOLW\PSP enhancing moisture-proofTwo parallel strength members ensure tensile strengthSmall outer diameter, light weight and friendly installationLong delivery length
Optical FiberTube Filling CompoundLoose Tube
Strength MemberWater Blocking TapePSP
PE Sheath
Marking Strip
Marking Strip
Technical Data
Tensile Strength (N)
Short term Long term
600
Short term
300
Static
10D
Crush Resistance (N/100m)
1500
Long term
1000
Long term
20D
Bending Radius (mm)
G.652 G.655 50/125µm 62.5/125µm
Attenuation (+20°C)
Bandwidth (Class A)
Numerical Aperture
Cable Cut-off Wavelength
@ 850nm ɚ����G%�NP ɚ����G%�NP
@ 1300nm ɚ����G%�NP ɚ����G%�NP
ɛ����0+]�NP ɛ����0+]�NP
ɛ�����0+]�NP ɛ����0+]�NP
ɚ�����G%�NP@ 1310nm ɚ�����G%�NP
ɚ�����G%�NP@ 1550nm ɚ�����G%�NP
ɚ����QP ɚ����QP
@ 850nm
@ 1300nm
�����s�����1$ �����s�����1$
Optical Charateristics
Ordering Information
Product code Core Quantity Fiber Type
ODGYXTW XXX
002���006
096
---
-
2 Cores4 Cores6 Cores
96 Cores
XX
SMM1M2M30�
-----
Singlemode G652D, 9µmOM1, 62.5µmOM2, 50µmOM3, 50µmOM4, 50µm
~
Sheath
X
L--
N/ALSZH
ExampleODGYXTW012M2� �*<;7:�VHULHV�RXWGRRU�PXOWLPRGH�20�����wP�ZLWK����FRUHV�ˉEHU�RSWLF�FDEOH�ODGYXTW008SML� �*<;7:�VHULHV�RXWGRRU�VLQJOHPRGH��wP����FRUHV�ˉEHU�RSWLF�FDEOH�ZLWK�/6=+�MDFNHW�
FIBER OPTICS
8
ODGYTS Series4-144 Cores Corrugated Steel Tape Armoured PE-UV BlackOutdoor Fiber Optic Cable
Installation: aerial, ductStructured features: metallic central strength member(phosphetedsteel wire), double plastic-coated corrugated steel tape - PE bondedouter sheath.Peformance characteristics: excellent crush resistance with steeltape armor, sound bullet-proof performance.Application: long-haul communication, communication betweenstations, especially suitable for application with high requirementof crush resistance like aerial installation.
Features
Water-blocking cable gel
PBT tube
2SWLFDO�ˉEHU
Double plastic-coated steel tape
PE outer sheath
Metallic strength member
:DWHU�EORFNLQJ�ˉEHU�MHOO\
33�ˉOWHU
6SHFLˉFDWLRQV
Cable cores Overall diameterof cable (mm)
Cable weight(kg/km)
Minimum bending radius Tension allowed (N) Crush resistance (N/100m)
Static Dynamic Short term Long term Short term Long term
4 - 8F 8.0 ±0.3 62 1500 500 3000 1000
12 - 24F 8.8 ±0.3 78 1800 500 3000 1000
24 - 60 10.5 ±0.3 112
1500 600 1000 30072 11.5 ±0.3 13810 times
O.D.20 times
O.D.96 13.5 ±0.3 165
120 15.8 ±0.3 222 2000 600 1000 300
144 15.8 ±0.3 222 2500 800 1000 300
Ordering Information
Product code Core Quantity Fiber Type
ODGYTS XXX
002004006
144
---
-
2 Cores4 Cores6 Cores
144 Cores
XX
Sheath
X
L--
N/ALSZH
SMM1M2M3M4
-----
Singlemode G652D, 9µmOM1, 62.5µmOM2, 50µmOM3, 50µmOM4, 50µm
~
ExampleODGYTS004SM �*<76�VHULHV�RXWGRRU�3(�VLQJOHPRGH��wP�ZLWK���FRUHV�ˉEHU�RSWLF�FDEOH� ODGYTS012M2L �*<76�VHULHV�RXWGRRU�PXOWLPRGH�20�����wP�����FRUHV�ˉEHU�RSWLF�FDEOH�ZLWK�/6=+�MDFNHW��
ODFPSHeat Shrinkable Fiber Splice Protection Sleeve
OverviewThe head-shrink splice protection sleeves are designed to ensuremaximum of splice protection. The construction consists of aSRO\ROHˉQH�VOHHYH�IRU�ˉEHU�SURWHFWLQ��D�VWHHO�URG�ZKLFK�JXDUDQWHHVWKH�UHLQIRUFHPHQW�RI�WKH�ˉEHU��DQG�D�KRW�IXVLRQ�WXEH�IRU�UHEXLOGLQJthe outer coating.
Features•••••
Maintains optic transmission properlyReinforce and protects splice3URWHFWV�ˉEHU�GXULQJ�LQVWDOODWLRQVOne pice designHot fusion sealing to protect the splice against dust and moisture
6SHFLˉFDWLRQV
Available Options
ODFPS45 ��PP�ˉEHU�SURWHFWLRQ�VOHHYH 45mm
ODFPS60 ��PP�ˉEHU�SURWHFWLRQ�VOHHYH 60mm
Color Transparent
-45° to +100°
110°
18MPa
Operating Temperature
Shrink Temperature
Tensile Strength
Ultimate Elongation 700%
0.94g/cm³
25KV/mm
Density
Dielectric Strength
2.5
±5%
Dielectric Constant
Longitudinal Change
Stainless Steel Rod
,QQHU�7XEH
2XWHU�6KULQN�7XEH
9
FIBER OPTICS
FIBER OPTICS
10
ODFConSCCMFiber Field Installable Connector
7KH�ˉEHU�ˉHOG�LQVWDOODEOH�FRQQHFWRU�LV�ZLGHO\�XVHG�LQ�)LEHU�7R7KH�+RPH��)77+��DFFHVV�RSWLFDO�QHWZRUNV��QRW�RQO\�IRU�VLQJOH�PRGH�RU�PXOWLPRGH�ˉEHU��DQG�FDQ�DOVR�FKRRVH�WR����XP���PPDQG�WKH�LQWURGXFWLRQ�RI�FDEOH�EXIIHUHG�W\SH��:LWK�IDVWLQVWDOODWLRQ�WLPH�DQG�ORZ�LQVHUWLRQ�ORVV��WKH�FRQQHFWRU�V\VWHPSURYLGHV�D�JRRG�DOWHUQDWLYH�WR�IXVLRQ�VSOLFLQJ��,QVWDOODWLRQ�LV�DVHDV\�DV�VWULS��FOHDQ��FOHDYH�FDP�DQG�FULPS�
Overview
•••••••
&RPSDWLEOH�ZLWK�VWDQGDUG�6&�FRQQHFWRUV)LHOG�LQVWDOODEOH��FRVW�HIIHFWLYH��XVHU�IULHQGO\83&��$3&�SROLVKLQJ�RSWLRQDO5HOLDEOH�GXUDEOH�DQG�VXSHULRU�RSWLFDO�SHUIRUPDQFH/RZ�LQVHUWLRQ�ORVV�DQG�KLJK�UHWXUQ�ORVV6WDEOH�FDSDELOLW\�DQG�KLJK�UHOLDELOLW\([FHOOHQW�PHFKDQLFDO�FDSDELOLW\
Features
6&�83&6&�$3&
,QQHU�6WUXFWXUH
6SHFLˉFDWLRQV
Connector Length
SC/UPC
��PP
Optical Fiber
Insertion Loss
�PP �PP�%XWWHUˊ\�7\SH
$YHUDJH�ɚ�����G%,0D[�ɚ����G%
Return Loss ɛ��G%
Thermal Shock ɚ����G%
SC/APC
��PP
�PP �PP�%XWWHUˊ\�7\SH
$YHUDJH�ɚ����G%,0D[�ɚ����G%
ɛ��G%
Storage / Operating Temperature ����a����
Tensile Strength ɛ���1
Average Assembly Time ɚ��PLQXWHV
Assembly Repeatability ɛ��WLPHV
One-Time Assembly Yield ɛ���
Fiber Connector/CouplerA variety type of Fiber Optic Connectors/Couplers
OverviewOptic Digital offers an extensive range of optical couplers for use inFTTx, telecommunications, data communications and CATV applications.$OO�FRXSOHUV�DUH�IXOO\�TXDOLˉHG�WR�7HOFRGLD�*5����DQG�,(&�������DQG�DOOPDWHULDOV�XVHG�DUH�5R+6�FRPSODLQW��&RXSOHUV�FDE�EH�VXSSOLHG�LQ�D�YDUHLW\RI�FRORUV�DQG�W\SHV�VXFK�DV�6&��)&��67��/&��(�����HWF�
Features•
•
•••
4XDOLˉHG�WR�7HOFRGLD�*5����DQG�,(&�������VWDQGDUGV�DQG�5R+6complaint materials.$YDLODEOH�IRU�PDQ\�GLIIHUHQW�FRQQHFWRU�W\SHV�VXFK�DV�6&��)&��67��/&�(������075-�HWF�All couplers are supplied with ceramic inserts.6XSSOLHG�LQ�D�UDQJH�RI�GLIIHUHQW�FRORUV�WR�PDWFK�FRQQHFWRU�W\SH�%RWK�VLPSOH[�DQG�GXSOH[�FRXSOHUV�DUH�DYDLODEOH�
Applications•••••
FTTxCATVData CommunicationTelecommunicationsTest and measurement
Technical Data
0D[LPXP�,QVHUWLRQ�/RVV��G%� ɚ�����7\SLFDO������83&�DQG�$3&�
ɛ�����83&���ɛ�����$3&�
,(&�������
���r&�WR�����r&
ɚ������83&�
Singlemode (1310 / 1550nm) Multimode (850nm)
5HWXUQ�/RVV��G%�
,QWHUPDWHDELOLW\
Not measured
,(&������
Operating temperature ���r&�WR�����r&
Available Options
ODConSCSM 6LQJOHPRGH�6&�ˉEHU�RSWLF�FRQQHFWRU 6&�FRQQHFWRU
ODConSTSM 6LQJOHPRGH�67�ˉEHU�RSWLF�FRQQHFWRU 67�FRQQHFWRU
ODCPLDSCSM 6LQJOHPRGH�6&�GXSOH[�ˉEHU�RSWLF�FRXSOHU 6&�FRXSOHU��GXSOH[�
ODCPLSSCSM 6LQJOHPRGH�6&�VLPSOH[�ˉEHU�RSWLF�FRXSOHU 6&�FRXSOHU��VLPSOH[�
ODCPLSSTSM 6LQJOHPRGH�67�VLPSOH[�ˉEHU�RSWLF�FRXSOHU 67�FRXSOHU��VLPSOH[�
ODCPLDLCSM 6LQJOHPRGH�/&�GXSOH[�ˉEHU�RSWLF�FRXSOHU /&�FRXSOHU��GXSOH[�
ODCPLDSCMM 0XOWLPRGH�6&�GXSOH[�ˉEHU�RSWLF�FRXSOHU 6&�FRXSOHU��GXSOH[�
6&�$GDSWHU��6LPSOH[ 6&�$GDSWHU��'XSOH[
)&�$GDSWHU��0XOWLPRGH
/&�$GDSWHU��0XOWLPRGH
67�$GDSWHU��0XOWLPRGH
)&�$GDSWHU��6LQJOHPRGH
/&�$GDSWHU��6LQJOHPRGH
67�$GDSWHU��6LQJOHPRGH
11
FIBER OPTICS
Fiber PigtailsA variety type of Fiber Optic Pigtails
OverviewHigh performance optical pigtails ensuring performs to the highestlevel. Offering an extensive range of optical pigtails for use in FTTx,telecommunications, data communications and CATV applications.$OO�SLJWDLOV�DUH�IXOO\�TXDOLˉHG�WR�5R+6�&RPSODLQW��&DQ�EH�VXSSOLHGin a variety of lengths and with a variety of different connector types.
Features••
••
••
)XOO�WUDFHDELOLW\�DQG�WHVW�FHUWLˉFDWLRQ�VXSSOLHG�ZLWK�HDFK�DVVHPEO\�Ultra polish (UPC) supplied as standard and Angle polish (APC) alsoDYDLODEOH�4XDOLI\�7HOFRUGLD�VWDQGDUG�DQG�5R+6�&RPSODLQW�PDWHULDOV�SURSHUWLHV�0DQ\�GLIIHUHQW�FRQQHFWRU�W\SHV�VXFK�DV�)&��6&��67��(������/&��',1�DQGothers on request.$YDLODEOH�LQ�VLQJOHPRGH�DQG�PXOWLPRGH���������DQG����������6WDQGDUG�FDEOH�GLDPHWHU�LV�����PLFURP�ZLWK�HDV\�VWULS�EXIIHULQJ�
Applications•••••
FTTxCATV'DWD�&RPPXQLFDWLRQTelecommunicationsTest and measurement
Technical Data
0D[LPXP�,QVHUWLRQ�/RVV��G%� ɚ�����7\SLFDO������83&�DQG�$3&�
ɛ�����83&���ɛ�����$3&�
,(&�������
���r&�WR�����r&
ɚ������83&�
Singlemode (1310 / 1550nm) Multimode (850nm)
5HWXUQ�/RVV��G%�
,QWHUPDWHDELOLW\
1RW�PHDVXUHG
,(&������
Operating temperature ���r&�WR�����r&
Ordering Information
Product code SM/MM Mode
2'37 XX
600�0�0�0�
�����
SM, 9µmOM1, 62.5µmOM2, 50µmOM3, 50µmOM4, 50µm
��
��
��
�
1m2m
99m
6&67/&FC
SC connectorST connectorLC connectorFC connector
����
Type of Connector
XX
Length
XX
~
ExampleODPTSMFC1� �)&�FRQQHFWRU�VLQJOHPRGH��wP�ˉEHU�SLJWDLOV�LQ���PHWHU�OHQJWK�
67�3LJWDLOV FC Pigtails
6&�3LJWDLOV /&�3LJWDLOV
6&�$3&�3LJWDLOV
FIBER OPTICS
12
Fiber PatchcordA variety type of Fiber Optic Patchcords
OverviewHigh performance optical patchcord ensuring performs to the highestlevel. Optic Digital offering an extensive range of optical pactcord foruse in FTTx, telecommunications, data communications and CATVDSSOLFDWLRQV��$OO�SDWFKFRUGV�DUH�IXOO\�TXDOLˉHG�WR�5R+6�&RPSODLQW��&DQbe supplied in a variety of lengths and with a variety of differentconnector types.
Features••
••
••••
)XOO�WUDFHDELOLW\�DQG�WHVW�FHUWLˉFDWLRQ�VXSSOLHG�ZLWK�HDFK�DVVHPEO\�Ultra polish (UPC) supplied as standard and Angle polish (APC)also available.4XDOLI\�7HOFRUGLD�VWDQGDUG�DQG�5R+6�&RPSODLQW�PDWHULDOV�SURSHUWLHV�0DQ\�GLIIHUHQW�FRQQHFWRU�W\SHV�VXFK�DV�)&��6&��67��(������/&��',1�DQGothers on request.$YDLODEOH�LQ�VLQJOHPRGH�DQG�PXOWLPRGH���������DQG����������6WDQGDUG�OHQJWK�VXSSOLHG�LV��P�WR���P�&DEOH�GLDPHWHUV�DYDLODEOH�LQ����PP���PP�DQG��PP�All connectors are supplied with ceramic ferrules.
Technical Data
0D[LPXP�,QVHUWLRQ�/RVV��G%� ɚ�����7\SLFDO������83&�DQG�$3&�
ɛ�����83&���ɛ�����$3&�
,(&�������
���r&�WR�����r&
ɚ������83&�
Singlemode (1310 / 1550nm) Multimode (850nm)
5HWXUQ�/RVV��G%�
,QWHUPDWHDELOLW\
1RW�PHDVXUHG
,(&������
Operating temperature ���r&�WR�����r&
Ordering Information
Product code SM/MM Mode
ODPC
Duplex/Simplex
X
Sheath
XXX
600�0�0�0�
�����
SM, 9µmOM1, 62.5µmOM2, 50µmOM3, 50µmOM4, 50µm
��
��
��
�
1m2m
99m
6&6&6&)&6&67FCFC)&676767/&/&/&6&/&)&/&67
SC to SCSC to FCSC to STFC to FCFC to STST to STLC to LCLC to SCLC to FCLC to ST
����������
Type of Connector
XXXX
Length
XX
N/ALSZH/
��
DuplexSimplex
D6
��
~
ExampleODPCDSCSC1SM� �6&�WR�6&�GXSOH[�VLQJOHPRGH�wP�ˉEHU�SDWFKFRUG�LQ���PHWHU�OHQJWK�
ODPCSSCST1SML� �6&�WR�67�VLPSOH[�VLQJOHPRGH�wP�ˉEHU�SDWFKFRUG�LQ���PHWHU�OHQJWK�ZLWK�/6=+jacket.
)&�3&�)&�3&
6&�3&�6&�3& 6&�83&�6&�83&
/&�3&�/&�3&
Applications•••••
FTTxCATVData CommunicationTelecommunicationsTest and measurement
13
FIBER OPTICS
ODPLC Series1x4-64 Optical Fiber PLC Splitter
OverviewThe ODPLC series splitter for today’s high-port count applicationsthat demand the best performance and the highest reliability underthe most adverse of environments. ODPLC Splitter modules deliveron all these requirements. The PLC module features low insertion loss,low polarization dependent loss, and high port-to-port uniformity. The3/&�6SOLWWHU�DUH�DYDLODEOH�LQ��[�����FKDQQHO�FRQˉJXUDWLRQV�ZLWK�6&�RULC pigtails.
Features••••
Low Insertion lossGood channel-to-channel uniformityHigh Reliability and StabilityExcellent Environmental Stability and Widely Used
Applications••••
FTTxCATV SystemsPON NetworksTelecommunications
Technical Data
Maximum
Operating Wavelength 1260-1650nm
Insertion Loss 8.0dB 11.5dB 14.7dB 18.3dB 22.7dB
Insertion Loss Uniformity 1.0dB 1.2dB 1.7dB 2.2dB 2.6dB
Polarization Dependent Loss 0.3dB 0.3dB 0.4dB 0.45dB 0.49dB
Directivity >55dB
Return Loss >50dB
Maximum Oprical Power 300MW
Operating Temperature -5°C to +65°C
Storage Temperature -40°C to +85°C
1x4 Port 1x8 Port 1x16 Port 1x32 Port 1x64 Port
Ordering Information
Product code Channel
ODPLC XX
0408163264
-----
1x4 Port1x8 Port1x16 Port1x32 Port1x64 Port
SCLC
SC connectorLC connector
--
Type of Connector
XX
ExampleODPLC16LC = 1x16 LC adapter PLC splitter.
FIBER OPTICS
14
Bundle Fiber PigtailsMulti Cores Rainbow Color Fiber Optic Pigtails
OverviewHigh performance multi core optical pigtails ensuring performs tothe highest level. Offering an extensive range of optical pigtails foruse in FTTx, telecommunications, data communications and CATVDSSOLFDWLRQV��$OO�SLJWDLOV�DUH�IXOO\�TXDOLˉHG�WR�5R+6�&RPSODLQW��&DQbe supplied in a variety of number of core and with a variety ofdifferent connector types.
Features••
••
••••
)XOO�WUDFHDELOLW\�DQG�WHVW�FHUWLˉFDWLRQ�VXSSOLHG�ZLWK�HDFK�DVVHPEO\�Ultra polish (UPC) supplied as standard and Angle polish (APC)also available.4XDOLI\�7HOFRUGLD�VWDQGDUG�DQG�5R+6�&RPSODLQW�PDWHULDOV�SURSHUWLHV�0DQ\�GLIIHUHQW�FRQQHFWRU�W\SHV�VXFK�DV�)&��6&��67��(������/&��',1�DQGothers on request.$YDLODEOH�LQ�VLQJOHPRGH�DQG�PXOWLPRGH���������DQG����������Multi core color pigtails are available.&DEOH�GLDPHWHUV�DYDLODEOH�LQ����PP�WR��PP�All connectors are supplied with ceramic ferrules.
Technical Data
Maximum Insertion Loss
UPC(SM)
ɚ���G%
APC(SM)
Maximum Return Loss ɛ��G% ɛ��G% ɛ��G%
Cable Diameter ���PP�����PP
Durability �����PDWLQJV������G%
Interchangeability ����G%
Operating Temperature ���r&�WR����r&
UPC(MM)
Applications•••••
FTTxCATV'DWD�&RPPXQLFDWLRQTelecommunicationsTest and measurement
15
FIBER OPTICS
Ordering Information
Product code SM/MM Mode
2'537 XX
600�0�0�M4
-----
SM, 9µmOM1, 62.5µmOM2, 50µmOM3, 50µmOM4, 50µm
������
---
4 Core8 Core12 Core
6&67/&FC
SC connectorST connectorLC connectorFC connector
----
Type of Connector
XX
Core
XX
ExampleODRPT12SMLC� ����&RUHV�6LQJOHPRGH�/&�FRQQHFWRU�EXQGOH�SLJWDLOV�
Waterproof Fiber PatchcordIP67 Waterproof Optical Fiber Pactcord
Overview
FIBER OPTICS
16
7KH�ZDWHUSURRI�ˉEHU�RSWLF�SDWFKFRUGV�DUH�GHVLJQHG�WR�ˉW�IRU�RXWGRRUDSSOLFDWLRQV��7KH�VWURQJ�38�MDFNHW�DQG�DUPRUHG�VWUXFWXUH�FDQ�UHVLVWKLJK�WHPSHUDWXUH�DQG�VXLW�WR�XVH�LQ�KDUVK�HQYLURQPHQW��7KHZDWHUSURRI�ˉEHU�SDWFKFRUG�FRQQHFWRU�PHHW�,3������HQYLURQPHQWDOVHDOLQJ�UDWLQJV�DQG�DUH�WKH�LGHDO�FKRLFH�IRU�D�ORZ�FRVW�DQG�HDV\�WRXVH�VROXWLRQ�LQ�LQGXVWULDO��ˉEHU�WR�WKH�$QWHQQD��RU�DQ\�RWKHU�KDUVKHQYLURQPHQWDO�DSSOLFDWLRQV��
Features•••••••
+LJK�WHPSHUDWXUH�VWDELOLW\/RZ�LQVHUWLRQ�ORVV:DWHU�SURRI��GXVW�SURRI�DQG�FRUURVLRQ�UHVLVWDQW%XPS�UHVLVWDQFH5HOLDEOH�DQG�FRVW�HIIHFWLYH�LQVWDOODWLRQ)XOO\�:DWHU�EORFNHG,3���VKHDWK�VHDOLQJ�UDWLQJ
Applications•••••
FTTH)77$/$1�7HW�HTXLSPHQW�*��*�%DVH�6WDWLRQ+RUL]RQWDO�DQG�9HUWLFDO�&DEOLQJ
Optical Characteristics
Insertion Loss
Singlemode
����G% ����G%
Return Loss ��G% ��G%
Storage Temperature ���r&��WR����r& ���r&��WR����r&
Operating Temperature ���r&��WR����r& ���r&��WR����r&
Repetition Test (Additional Loss) ���G% ���G%
Repetition Test (Return Loss Variability) ��G% ��G%
Temperature Stability (Additional Loss) ���G% ���G%
Temperature Stability (Return Loss Variability) ��G% ��G%
Bump Resistance �����EXPSV�#���J�DFFHOHUDWLRQ �����EXPSV�#���J�DFFHOHUDWLRQ
Tensile Strength 7HQVLOH�RI�����1�FDEOH�GHSHQGHQW 7HQVLOH�RI�����1�FDEOH�GHSHQGHQW
Multimode
ODTrayFiber Optic Splice Tray
Overview)LEHU�RSWLF�VSOLFH�WUD\�LV�XVHG�IRU�RSWLF�ˉEHU�PDQDJHPHQW�VWRUDJH�DQG�ˉEHU�RSWLF�IXVLRQ�VSOLFH�SURWHFWLRQ��HDV\�IRULQVWDOODWLRQ�DQG�PRYHPHQW�
7KH�VSOLFH�WUD\�H[SDQGV�ˉEHU�VSOLFH�FDSDELOLWLHV�DV�ZHOO�DVSURYLGHV�WKH�VSOLFLQJ�ORFDWLRQ�IRU�ˉEHU�RSWLF�FDEOHV��,W�FDQ�EHSXW�LQWR�WKH�ˉEHU�GLVWULEXWLRQ�IUDPH��ˉEHU�VSOLFH�FORVXUH�RSWLF�WHUPLQDO�ER[�HWF�
Features•••
6SOLFH�WUD\�FRQˉJXUDWLRQV�RIIHUHG���������DQG����)LEHUV�7\SHV�RI�6SOLFH�7UD\V��3ODVWLF��ZLWK�D�FOHDU�&RYHU�&DQ�EH�XVHG�LQ��8���8�RU��8�5DFN�PRXQW�SDWFK�SDQHOV�
Applications•••
)77[�QHWZRUNV'DWD�FRPPXQLFDWLRQ�QHWZRUNV,QGRRU�DSSOLFDWLRQV
6SHFLˉFDWLRQV
Capacity ������3RUWV
3UHORDGHG�$GDSWHUV
���r&�a����r&
ɚ�������r&�
Adapter
Environment Temperature
Relative Humidity
Atmosphere Pressure ���a����.3D
ɛ����0ķ����9��'&�
ɚ��NY��'&����PLQ�QR�VSDUN�RYHU
ɛ��PP
Insulated Resistance
Intensity
Fiber Bending Redius
�8�[����PP�[����PP
ɚ�NJ��(PSW\�
6SHFLDO�SRZGHU�FRDWLQJ
Dimensions
Weight
Surface Finish
17
FIBER OPTICS
Available Options
ODTray0602 ��3RUW�ˉEHU�RSWLF�VSOLFH�WUD\ ��3RUW
ODTray1202 ���3RUW�ˉEHU�RSWLF�VSOLFH�WUD\ ���3RUW
ODTray2402 ���3RUW�ˉEHU�RSWLF�VSOLFH�WUD\ ���3RUW
FIBER OPTICS
18
ODFWS86 x 86mm Fibre Wall Socket - Dual Fiber
The compact finer wall socket is designed for residential andbusiness applications and holds up to four finer terminations.This wall box enables the installation of either a single SiroccoBlown Tube cable using up to a 2 fiver blown unit or 2 finerruggedized cables to be spliced to 2 SC pigtails (PC or APC). Thepigtails would which connect to adapters at the base of the unit.
This box is has a transparent plastic cover on the front adapterside, providing substantial protection to the installed fibers. Theunit can be quickly installed within an office, house orcommunicationroom environment.
Overview
••••••••
SC simplex and duplex adapterErgonomic designAbility to allow cables to enter from rear or bottom of unit30mm minimum bend radiusFlip tray to allow access to pigtails and cable entryRemovable cover for easy accessManufactured from fire resistant UL94-Vo rated materialStandard white color
Features
•••
FTTx networksData communication networksIndoor applications
Applications Specifications
Height 86mm
86mm
25mm
1 or 2
Weight
Depth
Number Of Ports
Max. Splicing Capacity 2 Splices
SC simplex, SC Duplex
2
Suitable For Adapter Type
Number Of Cable Entry
PC+ABS
White
-40°C ~ +60°C
Meterial
Color
Operating Temperature
RoHS, REACH/SvHCComplaint
2':023����6&�ˉEHU�RSWLF�WHUPLQDWLRQ�ER[�LV�VXLWDEOH�IRU�)77+��RSWLFDO�ˉEHUVSOLWWLQJ�VSLFLQJ�XVH��7KH�HQFORVXUH�LV�XVHG�ZLWK�$%6�SODVWLF�PDWHULDO��OLJKWZHLJKW��UHDVRQDEOH�GHVLJQ�IRU�ˉEHU�DUUDQJHPHQW��DOORZV�EHQG�UDGLXV�PRUH�WKDQ��PP��,W�DOVR�VXLWDEOH�IRU��SF���ZD\�VSOLWWHU�RU��SF���ZD\�VSOLWWHU�ZLWK�/&FRQQHFWRU��6WHHO�WXEH�W\SH�
Fiber arranging drawings Dimensions
Dimensions and Capabilities
Height ���PP
Weight ���PP
Depth ��PP
Operating temperature ��r&����r&
Relative humidity ɚ�������r&�
Atmospheric pressure ��.SD������.SD
Storage temperature ���r&����r&
Optical parameter,QVHUWLRQ�ORVVɚ���G%�
([FHVV�ORVV�ɚ���%�
5HWXUQ�ORVVɛ��G%IP Standard ,3��
ODWMOP0404SC4-Port FTTH Fiber Termination Boxc/w 4pcs SC Adapters
Overview
19
FIBER OPTICS
ODWMOP0808SC8-Port Fiber Termination Box c/w 8pcs SC Adapters
7KLV�ˉEHU�RSWLFV�GLVWULEXWLRQ�ER[�RIIHUV�VSDFHV�IRU�VSOLWWHUVDQG�XS�WR���IXVLRQV��DOORFDWHV���6&�DGDSWHUV�DQG�ZRUNLQJXQGHU�LQGRRU�RU�RXWGRRU�HQYLURQPHQWV��,W�LV�D�SHUIHFWFRVW�HIIHFWLYH�VROXWLRQ�SURYLGHU�LQ�WKH�)77[�QHWZRUNV�
Overview
•••••
•
0HFKDQLFDO�VHDO��JRRG�VHDOLQJ��FDQ�UHSHDW�XVH3URWHFWLYH�OHYHO��,3��/D\LQJ��RXWGRRU�ZDOO�PRXQWLQJ�DQG�SROH�PRXQWLQJ)77+��SDVVLYH�RSWLFDO�SRLQWV�ZLULQJ�VSHFLDO�WHUPLQDO�ER[7KH�ER[�ERG\�WR�VFUROO�W\SH�VWUXFWXUH��LW�KDV�WKH�IXQFWLRQRI�JXDUG�DJDLQVW�WKHIW��ODUJH�FDSDFLW\�IXQFWLRQ�FRPSOHWH&DQ�EH�LQVWDOOHG�����6&�PRGXOH�W\SH�VSOLWWHU
Features
Dimensions and Capabilities
Adapter Capacity 6&����FRUHV
���PP ���PP ��PP
�
���NJ
Dimensions (W*H*D)
Number of Cable Entrance
Weight
Installation $GDSWHUV��3LJWDLOV��+HDW�6KULQN�7XEHV��6SOLFH�7UD\��2SWLFDO�6SOLWWHU:DOO�0RXQWHG�RU�3ROH�0RXQWLQJ
Operation Conditions
Temperature ���r&�a���r&
����DW���r&
��N3D�ȝ����N3D
Humidity
Air Pressure
FIBER OPTICS
20
ODWMOP1616SC16-Port Fiber Termination Box c/w 16pcs SC Adapters
This distribution box is used as a termination point for thefeeder cable to connect with drop cable in FTTxFRPPXQLFDWLRQ�QHWZRUN�V\VWHP��7KH�ˉEHU�VSOLFLQJ��VSOLWWLQJ�GLVWULEXWLRQ�FDQ�EH�GRQH�LQ�WKLV�ER[��DQG�PHDQZKLOH�LWSURYLGHV�VROLG�SURWHFWLRQ�DQG�PDQDJHPHQW�IRU�WKH�)77[QHWZRUN�EXLOGLQJ�
Overview
•••••
••••
Total enclosed structure.Material: PC+ABS:HW�SURRI��ZDWHU�SURRI��GXVW�SURRI��DQWL�DJLQJProtection level up to IP65.&ODPSLQJ�IRU�IHHGHU�FDEOH�DQG�GURS�FDEOH��ˉEHU�VSOLFLQJ�ˉ[DWLRQ��VWRUDJH��GLVWULEXWLRQ�DOO�LQ�RQH�6XLWDEOH�IRU�6&�DQG�/&�GXSOH[�DGDSWHU�DQG�SLJWDLOEasy to operateSuitable for both outdoor and indoor use3URWHFWV�DQG�PDQDJHV�FDEOH�HIIHFWLYHO\
Features
Dimensions and Capabilities
Adapter Capacity SC: 8 cores
230mm*198mm*60mm
1
���NJ
Dimensions (W*H*D)
Number of Cable Entrance/Exit
Weight
$GDSWHUV��3LJWDLOV��+HDW�6KULQN�7XEHV��6SOLFH�7UD\��2SWLFDO�6SOLWWHU
ɚ���G%
Optional Accessories
Insertion loss
ɛ��G%
ɛ��G%
UPC return loss
APC return loss
ɛ�����WLPHVLife of insertion & extraction
Operation Conditions
Temperature -40°C ~ 85°C
ɛ����DW���r&
70kPa – 106kPa
Humidity
Air Pressure
21
FIBER OPTICS
ODWMOP2424SC24-Port Fiber Termination Box c/w 24pcs SC Adapters
This distribution box is used as a termination point for thefeeder cable to connect with drop cable in FTTxFRPPXQLFDWLRQ�QHWZRUN�V\VWHP��7KH�ˉEHU�VSOLFLQJ��VSOLWWLQJ�GLVWULEXWLRQ�FDQ�EH�GRQH�LQ�WKLV�ER[��DQG�PHDQZKLOH�LWSURYLGHV�VROLG�SURWHFWLRQ�DQG�PDQDJHPHQW�IRU�WKH�)77[QHWZRUN�EXLOGLQJ�
Overview
•••••
••••
Total enclosed structure.Material: PC+ABS:HW�SURRI��ZDWHU�SURRI��GXVW�SURRI��DQWL�DJLQJProtection level up to IP65.&ODPSLQJ�IRU�IHHGHU�FDEOH�DQG�GURS�FDEOH��ˉEHU�VSOLFLQJ�ˉ[DWLRQ��VWRUDJH��GLVWULEXWLRQ�DOO�LQ�RQH�6XLWDEOH�IRU�6&�DQG�/&�GXSOH[�DGDSWHU�DQG�SLJWDLOEasy to operateSuitable for both outdoor and indoor use3URWHFWV�DQG�PDQDJHV�FDEOH�HIIHFWLYHO\
Features
Dimensions and Capabilities
Adapter Capacity SC: 24 cores
230mm*198mm*60mm
2
���NJ
Dimensions (W*H*D)
Number of Cable Entrance/Exit
Weight
$GDSWHUV��3LJWDLOV��+HDW�6KULQN�7XEHV��6SOLFH�7UD\��2SWLFDO�6SOLWWHU
ɚ���G%
Optional Accessories
Insertion loss
ɛ��G%
ɛ��G%
UPC return loss
APC return loss
ɛ�����WLPHVLife of insertion & extraction
Operation Conditions
Temperature -40°C ~ 85°C
ɛ����DW���r&
70kPa – 106kPa
Humidity
Air Pressure
FIBER OPTICS
22
ODWMOP2412LCOutdoor ABS Fiber Wall Mount Enclosure withSplicing Tray & Adapters
FTTH outdoor drop cable is constructed with two singlePRGH�ˉEHU��7KH�FDEOH�LV�SURWHFWHG�E\�D�GLHOHFWULF�VWUHQJWKPHPEHU�PDGH�RI�ˉEHUJODVV�UHLQIRUFHG�SODVWLF��)53����VWHHOZLUH�DQG�D�/6=+�RXWHU�MDFNHW�Designed for outdoor installation the cable is well suitedfor connections between the dome closure and smallGZHOOLQJ�XQLW���ZDUHKRXVH�DQG�LQGHSHQGHQW�YLOODV�
Description
ȧ��,3���UDWLQJ�IRU�H[WHUQDO�XVHȧ��/RFNDEOH�GRRU�IRU�DGGHG�VHFXULW\• Integrated cable tie points for securing incoming cable• Up to 24 splice & LC connection pointsȧ��5HPRYDEOH�VSOLFH�WUD\�IRU�HDV\�LQVWDOODWLRQȧ��$FFHSWV�ORRVH�WXEH��GLVWULEXWLRQ�DQG�SUH�WHUPLQDWHG�FDEOHV• Integrated bend radius protectionȧ��6HDOLQJ�JODQGV�IRU�XS�WR����H[LVWLQJ�����LQFRPLQJ�FDEOHVȧ��5HPRYDEOH�GRRU�IRU�HDVH�RI�LQVWDOODWLRQ• Supplied with 24 heatshrink splice protectors• Supplied with transit tubingȧ��6XSSOLHG�ZLWK�ZDOO�ˉ[LQJ�DQG�WLH�ZHDSVȧ��5R+6��5($&+��6Y+&�FRPSODLQW
Features
6SHFLˉFDWLRQV
Height 340mm
270mm
110mm
���NJ
Weight
Depth
Net Weight
IP Rating ,3��
/&�VLPSOH[
24
2
Suitable For Adapter Type
Number Of Ports
Cable Entry
ABS
*UH\�5D\�����
���r&�a����r&
Meterial
Color
Operating Temperature
5R+6��5($&+�6Y+&Complaint
Applications••••••
Data center3UHPLVH�LQVWDOODWLRQVTelecommunication1HWZRUNV�(WKHUQHW)LEHU�FKDQQHO��$70��/$1��0$1WAN Data communication and telecommunicationQHWZRUNV�,QGRRU�RXWGRRU�DSSOLFDWLRQV�
23
FIBER OPTICS
ODWMOP4848SC48-Port Fiber Termination Box c/w 48pcs SC Adapters
This distribution box is used as a termination point for thefeeder cable to connect with drop cable in FTTxFRPPXQLFDWLRQ�QHWZRUN�V\VWHP��7KH�ˉEHU�VSOLFLQJ��VSOLWWLQJ�GLVWULEXWLRQ�FDQ�EH�GRQH�LQ�WKLV�ER[��DQG�PHDQZKLOH�LWSURYLGHV�VROLG�SURWHFWLRQ�DQG�PDQDJHPHQW�IRU�WKH�)77[QHWZRUN�EXLOGLQJ�
Overview
••
•
•
•
Total enclosed structure.0DWHULDO��3&�$%6��ZHW�SURRI��ZDWHU�SURRI��GXVW�SURRI��SURWHFWLRQ��level up to IP55.&ODPSLQJ�IRU�IHHGHU�FDEOH�DQG�GURS�FDEOH��ˉEHU�VSOLFLQJ��ˉ[DWLRQ�VWRUDJH��GLVWULEXWLRQ���HWF�DOO�LQ�RQH�&DEOH��SLJWDLOV��SDWFK�FRUGV�DUH�UXQQLQJ�WKURXJK�RZQ�SDWK�ZLWKRXW�GLVWXUELQJ�HDFK�RWKHU��FDVVHWWH�W\SH�6&�DGDSWRU�LQVWDOODWLRQ��HDV\�maintenance.&DELQHW�FDQ�EH�LQVWDOOHG�E\�WKH�ZD\�RI�ZDOO�PRXQWHG�RU�SROHG�PRXQWHG��suitable for both indoor and outdoor uses.
Features
Dimensions and Capabilities
Max. Capacity Splitter: 48 / Splice: 48
410mm*360mm*120mm
ɚ�����G%
ɛ����G%
Dimensions (W*H*D)
Insertion loss
UPC return loss
ɛ����G%
>1000 times
APC return loss
Life of insertion and extraction
Operation Conditions
Temperature ���r&�a���r&
����DW���r&
70kPa – 106kPa
Humidity
Air Pressure
FIBER OPTICS
24
Wall Mount Enclosure (Indoor)Fiber Wall Mount Metal Enclosure With Adapters
OverviewMost widely used premium panels for datacentre applications. TheOLJKW�ZHLJKW�DQG�HDVLHU�ˉFWXUHV�HQDEOH�LQVWDOODWLRQ�HDVH�DQG�VPRRWKWHUPLQDWLRQV��7KLV�ˉEHU�ZDOO�PRXQW�PHWDO�HQFORVXUH�LV�SUHORDGHG�ZLWKVQDS�LQ�ˉEHU�DGDSWHUV�
Features••
•••
Light weight design7KH�VKHOO�LV�KLJK�LQWHQVLˉHG��LQVXODWHG�PDWHULDO��WKXV�KDYLQJexcellent mechanic performance)XOO�DFFHVVRULHV�IRU�FRQYHQLHQW�RSHUDWLRQV5HOLDEOH�ˉEHU�OHDG��JURXQGLQJ�DQG�SHUIHFW�ˉ[�XS5HOLDEOH�SLJWDLO�ˉ[HV�XS�DQG�SHUIHFW�SURWHFWLRQ
6SHFLˉFDWLRQV
Capacity 6-24 Ports
Preloaded Adapters
-40°C ~ +80°C
ɚ�����ZKHQ�WHPSHUDWXUH�LV�EHORZ���r&�
Adapter
Environment Temperature
Relative Humidity
Atmosphere Pressure 70 ~ 106KPa
ɛ����0ķ����9��'&�
ɚ��NY��'&����PLQ�QR�VSDUN�RYHU
ɛ��PP
Insulated Resistance
Intensity
Fiber Bending Redius
Available Options
ODWMB0606SC ��SRUW�ZDOO�PRXQW�PHWDO�HQFORVXUH�F�Z��SFV�6&�DGDSWHUV 6&��ZLWK��SFV�DGDSWHUV
ODWMB1212SC ���SRUW�ZDOO�PRXQW�PHWDO�HQFORVXUH�F�Z���SFV�6&�DGDSWHUV 6&��ZLWK���SFV�DGDSWHUV
ODWMB2424SC ���SRUW�ZDOO�PRXQW�PHWDO�HQFORVXUH�F�Z���SFV�/&�DGDSWHUV 6&��ZLWK���SFV�DGDSWHUV
ODWMB2412LC /&����SRUW�ZDOO�PRXQW�PHWDO�HQFORVXUH�F�Z���SFV�/&�DGDSWHUV /&��ZLWK���SFV�DGDSWHUV
25
FIBER OPTICS
ODOM SeriesOutdoor Metal Termination Box with Splicing Tray & Adapters
Overview2'20�6&�RXWGRRU�ˉEHU�RSWLF�WHUPLQDWLRQ�ER[�FRPHV�ZLWK�VSOLFLQJWUD\�DQG�ˉEHU�DGDSWHUV��,W�LV�PDGH�RI�FROG�UROOHG�VWHHO�PDWHULDO�ZLWKWKH�VXUIDFH�WUHDWHG�ZLWK�HOHFWURVWDWLF�VSUD\LQJ�WHFKQLTXH��$QG�LWV$%6�VSOLFLQJ�WUD\�FDQ�VLPXOWDQHRXVO\�VSOLFH�����������������DQG�PRUHˉEHUV��:LWK�,3���VWDQGDUG��WKLV�RXWGRRU�ˉEHU�RSWLF�WHUPLQDWLRQ�ER[LV�VXLWDEOH�IRU�ERWK�LQGRRU�DQG�RXWGRRU�ZDOO�PRXQW�RU�SROH�PRXQWDSSOLFDWLRQV�LQ�)77+��WHOHFRPPXQLFDWLRQV��&$79�DQG�HWF�
Features••
•••
•••••
&ROG�UROOHG�VWHHO��UHLQIRUFHG�VWUXFWXUH��HOHFWURVWDWLF�VSUD\LQJ��ˉEHU�FDEOH�LQOHW�RXWOHW�SRUWV��HDVLO\�RSHUDWLRQ��FRPSDFWVWUXFWXUH��VPDOO�VL]H6SOLFLQJ�WUD\�DQG�ˉEHU�FRQQHFWRU�LQFOXGHG6&�RU�/&�DGDSWRU�SDQHOV��WRWDO����SRUWV)LUPO\�UHLQIRUFHG�VWUXFWXUH��GXUDEOH��ˉQH�DSSHDUDQFH��ZLWK�DORFN��GXVW�SURRI��OLIHVSDQ�����\HDUV(QFORVXUH�GRRU�FDQ�EH�RSHQ�����|��IUHH�RSHUDWLRQ�VSDFH�:KROH�RSWLF�SDWK�GHVLJQ��)LEHU�EHQG�UDGLXV!��PP5HVRQDEOH�ˉEHU�SDWK��FOHDU�VLJQ&DSDFLW\�LV�RSWLRQDO�IURP���FRUHV�WR���FRUHV(QWHUHG�FDEOH�VSOLFHG�ZLWK�SLJWDLOV��LQGRRU�FRYHUHG�ZLUHVFRQQHFWLQJ�TXLFN�FRQQHFWRU��ˉQDOO\�FRQQHFW�WKURXJK�6&�)&DGDSWRUV�
6SHFLˉFDWLRQV
Available Options
ODOM2412SC ���SRUW�RXWGRRU�PHWDO�WHUPLQDWLRQ�ER[�ZLWK�VSOLFLQJ�WUD\����SFV�6&�DGDSWHUV ���SRUW��ZLWK���SFV�DGDSWHUV
ODOM4824SC ���SRUW�RXWGRRU�PHWDO�WHUPLQDWLRQ�ER[�ZLWK�VSOLFLQJ�WUD\����SFV�6&�DGDSWHUV ���SRUW��ZLWK���SFV�DGDSWHUV
ODOM7248SC ���SRUW�RXWGRRU�PHWDO�WHUPLQDWLRQ�ER[�ZLWK�VSOLFLQJ�WUD\����SFV�6&�DGDSWHUV ���SRUW��ZLWK���SFV�DGDSWHUV
ODOM9648SC ���SRUW�RXWGRRU�PHWDO�WHUPLQDWLRQ�ER[�ZLWK�VSOLFLQJ�WUD\����SFV�6&�DGDSWHUV ���SRUW��ZLWK���SFV�DGDSWHUV
Meterial &ROG�UROOHG�6WHHO
*UH\
���r&�a����r&
������ZKHQ�WHPSHUDWXUH�LV�EHORZ����
Color
Environment Temperature
Relative Humidity
Atmospheric Pressure ���a����.3D
ɛ�����0ķ����9'&
QR�DUF�FRYHU�XQGHU���.9'&��PLQ
Insulation Resistance
Voltage Resistance Strength
3&!��G%��83&!��G%��$3&!��G%
!�����WLPHV
lnsertion Loss
Connection Life Span
FIBER OPTICS
26
GPX82-11Mini Cold-rolled Steel Distribution Frame
Overview
6SHFLˉFDWLRQV
For Cross Connect (SC) 600*150*600 24
48
48
96
216
600*150*600
600*300*600
600*300*600
For Cross Connect (LC)
For Shell and Core buildings (SC)
For Shell and Core buildings (LC)
Splice Cabinet 600*300*600
-30°C ~ +75°CTemperature
Operating Conditions
ɚ����DW���r&
��.3D�a����.3D
Humidity
Air Pressure
0LQL�2')�LV�FXUUHQWO\�EHLQJ�ZLGHO\�XVHG�IRU�GLVWULEXWLQJ�RXWGRRU�RSWLFDO�FDEOH�LQ�LQGRRU�FRQGLWLRQV��,W�LV�YHU\�VXLWDEOH�IRU�)77[�XVHV��7KLV�ER[�RIIHUV�LGHDO�HQYLURQPHQW�IRU�ˉEHUV�WR�EH�VSOLFHG�DQG�ZHOO�RUJDQL]HG�XQGHU�LQGRRU�HQYLURQPHQW�
Features•
•
•••••
7KH�ER[�KDV�IXQFWLRQV�RI�FDEOH�WHUPLQDWLRQ��VSOLFLQJ��GLVWULEXWLRQ�DQGFURVV�FRQQHFWLRQ�6ROLG�VWUXFWXUH�ZLWK�WKH�DGYDQWDJHV�RI�JRRG�SHUIRUPDQFH�RI�GXVW�SURRI�SOHDVLQJ�DQG�QHDW�DSSHDUDQFH�(DV\�LQVWDOODWLRQV��:DOO�PRXQWDEOH�,GHDO�IRU�LQGRRU�XVHV�ȝ�FDEOH�HQWUDQFHV��H[LWV�ORFDWHG�RQ�ERWK�WRS�DQG�ERWWRP�/RFN�SURYLGHG�RQ�HYHU\�ER[�HQVXUHV�WKH�VDIHW\�RI�WKH�ˉEHUV�7KH�FHQWUDO�DGDSWHU�ERDUG�VHSDUDWHV�WKH�LQFRPLQJ�FDEOHV�DQG�WKH�H[LWLQJ�ˉEHUV$GRSWDEOH�DGDSWHU�W\SHV��6&��/&�'XSOH[
28 27
FIBER OPTICS
ODTray SeriesFiber Outdoor Termination Box With Splicing Tray
OverviewThe ODTray series inline enclosure is a horizontal type with a hingeon one side and an opening on the other side. Two insert plates,ZLWK�ˉ[LQJ�EROWV��DUH�XVHG�WR�ˉ[�DQG�VHDO�LQOLQH�HQFORVXUH�
The ODTray series inline enclosure has our advanced formula, companySDWHQW�HODVWLF�VHDO�ˉWWLQJ��RXU�ˉWWLQJ�LV�PDGH�RI�LQMHFWLRQ�PROGHG�high quality elastic material via numerical control equipment. It isLQVWDOOHG�EHWZHHQ�WKH�HQFORVXUH�KRXVLQJ�DQG�WKH�LQVHUW�SODWHV�
6SHFLˉFDWLRQV
24 ~ 96F 144 ~ 192F
6 ports (3 each side)
Ø8 ~ 16(mm)
Bunchy: 6 ~ 96 (Cores)5LEERQ��0D[�������&RUHV�
Number of inlet/outlet ports
Suitable cable jacket diameter
Maximum capacity (F)
���[���[����PP�
���NJ�a����NJ
���[���[����PP�
Single piece package size
Single piece package weight
Group package size
��SFV�FDUWRQ
6 ports (3 each side)
���a����PP�
%XQFK\�����a������&RUHV�5LEERQ��0D[������&RUHV�
���[���[����PP�
���NJ�a����NJ
���[���[����PP�
�SFV�FDUWRQGroup package quantity
FIBER OPTICS
28
Available Options
ODTray2401 ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLF�WUD\ ���3RUW����6SOLFH�7UD\
ODTray4802 ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLF�WUD\V ���3RUW����6SOLFH�7UD\V
ODTray7203 ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLF�WUD\V ���3RUW����6SOLFH�7UD\V
ODTray9604 ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLF�WUD\V ���3RUW����6SOLFH�7UD\V
ODOP-LC SeriesFiber Outdoor PVC Box with Splicing Tray & LC Adapters
The ODOP inline enclosure is a horizontal type with a hingeon one side and an opening on the other side. Two insertSODWHV��ZLWK�ˉ[LQJ�EROWV��DUH�XVHG�WR�ˉ[�DQG�VHDO�LQOLQH�HQFORVXUH�
The ODOP inline enclosure has our advanced formula, companySDWHQW�HODVWLF�VHDO�ˉWWLQJ��RXU�ˉWWLQJ�LV�PDGH�RI�LQMHFWLRQ�PROGHG�high quality elastic material via numerical control equipment. It isLQVWDOOHG�EHWZHHQ�WKH�HQFORVXUH�KRXVLQJ�DQG�WKH�LQVHUW�SODWHV�
Overview
6SHFLˉFDWLRQV
24 ~ 96F 144 ~ 192F
6 ports (3 each side)
Ø8 ~ 16(mm)
Bunchy: 6 ~ 96 (Cores)5LEERQ��0D[�������&RUHV�
Number of inlet/outlet ports
Suitable cable jacket diameter
Maximum capacity (F)
���[���[����PP�
���NJ�a����NJ
���[���[����PP�
Single piece package size
Single piece package weight
Group package size
��SFV�FDUWRQ
6 ports (3 each side)
���a����PP�
%XQFK\�����a������&RUHV�5LEERQ��0D[������&RUHV�
���[���[����PP�
���NJ�a����NJ
���[���[����PP�
�SFV�FDUWRQGroup package quantity
29
FIBER OPTICS
Available Options
ODTray2412LC ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLFH�WUD\����SFV�/&�DGDSWHUV ���3RUW����6SOLFH�7UD\�����/&�$GDSWHUV
ODTray4824LC ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLFH�WUD\V����SFV�/&�DGDSWHUV ���3RUW����6SOLFH�7UD\V�����/&�$GDSWHUV
ODTray7236LC ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLFH�WUD\V����SFV�/&�DGDSWHUV ���3RUW����6SOLFH�7UD\V�����/&�$GDSWHUV
ODTray9648LC ���SRUW�ˉEHU�RSWLF�LQOLQH�HQFORVXUH�ZLWK���VSOLFH�WUD\V����SFV�/&�DGDSWHUV ���3RUW����6SOLFH�7UD\V�����/&�$GDSWHUV
Rack Mount Patch PanelFiber Rack Mount Patch Panel with Adapters
OverviewMost widely used premium panels for datacentre applications. theOLJKW�ZHLJKW�DQG�HDVLHU�ˉFWXUHV�HQDEOH�LQVWDOODWLRQ�HDVH�DQG�VPRRWKWHUPLQDWLRQV��7KLV�ˉEHU�UDFN�PRXQW�PHWDO�HQFORVXUH�LV�SUHORDGHG�ZLWKVQDS�LQ�ˉEHU�DGDSWHUV�
Features••
•••
Light weight design7KH�VKHOO�LV�KLJK�LQWHQVLˉHG��LQVXODWHG�PDWHULDO��WKXV�KDYLQJexcellent mechanic performance)XOO�DFFHVVRULHV�IRU�FRQYHQLHQW�RSHUDWLRQV5HOLDEOH�ˉEHU�OHDG��JURXQGLQJ�DQG�SHUIHFW�ˉ[�XS5HOLDEOH�SLJWDLO�ˉ[HV�XS�DQG�SHUIHFW�SURWHFWLRQ
6SHFLˉFDWLRQV
Capacity 12-24 Ports
Preloaded Adapters
-40°C ~ +80°C
ɚ�������r&�
Adapter
Environment Temperature
Relative Humidity
Atmosphere Pressure 70 ~ 106KPa
ɛ����0ķ����9��'&�
ɚ��NY��'&����PLQ�QR�VSDUN�RYHU
ɛ��PP
Insulated Resistance
Intensity
Fiber Bending Redius
�8�[����PP�[����PP
ɚ�NJ��(PSW\�
Special powder coating
Dimensions
Weight
Surface Finish
Available Options
ODRMB1212SC SC 12-port rack mount metal enclosure c/w 12pcs SC adapters SC, with 12pcs adapters
ODRMB2424SC SC 24-port rack mount metal enclosure c/w 24pcs SC adapters SC, with 24pcs adapters
ODRMB2406LC LC 24-port rack mount metal enclosure c/w 6pcs LC adapters LC, with 6pcs adapters
ODRMB2412LC LC 24-port rack mount metal enclosure c/w 12pcs LC adapters LC, with 12pcs adapters
FIBER OPTICS
30
Drawer Patch PanelFiber Drawer Rack Mount Patch Panel with Adapters
OverviewMost widely used premium panels for datacentre applications. theOLJKW�ZHLJKW�DQG�HDVLHU�ˉFWXUHV�HQDEOH�LQVWDOODWLRQ�HDVH�DQG�VPRRWKWHUPLQDWLRQV��7KLV�ˉEHU�UDFN�PRXQW�PHWDO�HQFORVXUH�LV�SUHORDGHGZLWK�VQDS�LQ�ˉEHU�DGDSWHUV�
Features••
••••
Light weight design7KH�VKHOO�LV�KLJK�LQWHQVLˉHG��LQVXODWHG�PDWHULDO��WKXV�KDYLQJexcellent mechanic performance6OLGDEOH��HDV\�IRU�LQVWDOODWLRQ)XOO�DFFHVVRULHV�IRU�FRQYHQLHQW�RSHUDWLRQV5HOLDEOH�ˉEHU�OHDG��JURXQGLQJ�DQG�SHUIHFW�ˉ[�XS5HOLDEOH�SLJWDLO�ˉ[HV�XS�DQG�SHUIHFW�SURWHFWLRQ
6SHFLˉFDWLRQV
Capacity 12-24 Ports
Preloaded Adapters
-40°C ~ +80°C
ɚ�������r&�
Adapter
Environment Temperature
Relative Humidity
Atmosphere Pressure 70 ~ 106KPa
ɛ����0ķ����9��'&�
ɚ��NY��'&����PLQ�QR�VSDUN�RYHU
ɛ��PP
Insulated Resistance
Intensity
Fiber Bending Redius
�8�[����PP�[����PP
ɚ�NJ��(PSW\�
Special powder coating
Dimensions
Weight
Surface Finish
Available Options
ODDRM2424SC 6&����SRUW�GUDZHU�UDFN�PRXQW�PHWDO�HQFORVXUH�F�Z���SFV�6&�DGDSWHUV 6&��ZLWK���SFV�DGDSWHUV
ODDRM2414LC /&����SRUW�GUDZHU�UDFN�PRXQW�PHWDO�HQFORVXUH�F�Z���SFV�/&�DGDSWHUV /&��ZLWK���SFV�DGDSWHUV
31
FIBER OPTICS
OD MTP/MPO Patch PanelFiber Integrated Solution
Overview7KLV�+LJK�'HQVLW\�ˉEHU�SDWFK�SDQHOV�DUH�GHVLJQHG�WR�DFFRPPRGDWHKLJK�GHQVLW\�DSSOLFDWLRQV�LQ�'DWD�&HQWHUV�DQG�7HOHFRPPXQLFDWLRQHQYLURQPHQWV��7KLV�IDFWRU\�SUH�SRSXODWHG�DQG�WHVWHG�ˉEHU�SDWFKSDQHO�VDYHV�RQ�VLWH�LQVWDOODWLRQ�WLPH�DQG�LQFUHDVH�UHOLDELOLW\��IDFWRU\SUH�ORDGHG�ZLWK�4W\�������������ˉEHU�/&�'XSOH[�2'�073�032&DVVHWWHV�RU�������2'�.�$GDSWHU�3ODWHV�IRU�TXLFN�LPSOHPHQWDWLRQVLQ�������*�QHWZRUNV�
Features••••••
83�WR�����)LEHU�/&�3RUWV�LQ��8)OH[LELOLW\�WR�0L[�$GDSWHU�3ODWHV�ZLWK�&DVVHWWHV�LQ�3DWFK�3DQHO$YDLODEOH�LQ�60��20���20���20��DQG�20��ˉEHU�JUDGHV(DVLO\�$FFHVVLEOH�032�073�3RUWV�IRU�&RQQHFWLRQ�WR�7UXQN�&DEOH)DFWRU\�WHUPLQDWHG�DQG�WHVWHG032�073�FRPSRQHQWV�IHDWXUH�VXSHULRU�RSWLFDO�DQG�PHFKDQLFDOSURSHUWLHV
6SHFLˉFDWLRQV
Height / Width �8�����PP ���PP ��PP�
Quantity of Cassette/Plate 2'�-�&DVVHWWH�[�� 2'�.�3ODWH�[�� 0D[�&DSDFLW\����
Operating Temperature ���r&�a����r&
Storage Temperature ���r&�a����r&
Humidity ����DW���r&�
Air Pressure ��N3D�ȝ����N3D
2'�-�&DVVHWWH�7HFKQLFDO�6SHFLˉFDWLRQV
OD-J-1 OD-J-2 OD-J-3
Total Fiber Count �� �� ��
Front Port Count � �� ��
Rear Port Count � � �
/&�'XSOH[ /&�'XSOH[ /&�'XSOH[Front Adapter Type
073�032 073�032 073�032Rear Adapter Type
OD-K-1 OD-K-2
Total Fiber Count �� ��
Front Adapter Type /&�'XSOH[ /&�'XSOH[
Front Port Count � ��
2'�.�3ODWH7HFKQLFDO�6SHFLˉFDWLRQV
2'.�-�&DVVHWWH
2'�.�3ODWH
FIBER OPTICS
32
NETWORK INFRASTRUCTURE02
NETWORK INFRASTRUCTURE
34
OD5000 Series24AWG CAT5E UTP Network Cables
OverviewEach Cat5E UTP cable is performance optimized with 4 balancedtwisted pairs on 24 AWG insulated solid bare copper conductors.2'�&DW�(�873�FDEOHV�DUH�FRQVWUXFWHG�WR�FUHDWH�D�URXQG�DQG�ˊH[LEOHcable for easy pulling and stripping of the PVC jacket.
Applications•••••
Horizontal Wiring in LANIEEE 802.3: 10/100/1000 Base-TIEEE 802.5 16MBPower Over Ethernet PoE/PoE+IEEE 802.3af and IEEE 802.3at
Standards••••
ANSI / TIA 568-C.2ISO / IEC 11801 2nd EdIEC 61156-5 2nd EdEN 50173; EN 50288-3-1:2013
Physical Characteristics
Available Options
Conductor Solid Bare Copper
AWG 24
Conductor Diameter 0.5 (± 0.0005mm)
Insulation PVC, LSZH
Insulation Diameter Ø0.9mm
Jacket PVC, LSZH
Jacket Cover PVC, LSZH: Grey
Outer Diameter 4.8 (± 0.3mm)
Weight 28kg /km
Machanical Characteristics
Minimum Bending Radius
Maximum Tensile Load
��[�'LDPHWHU
Nom. 100N
Maximum Tensile Load, Installed
Temperature During Operation
No Stretch
-20°C ~ +60°C
Temperature During Installation 0°C ~ +50°C
Electrical Characteristics
Characteristic impedance (1-130 MHz)
Mean Characteristic impedance 100 Mhz
�����s�����ķ
�����s����ķ�
DC-loop resistance
Resistance unbalance
1RP������ķ��NP
ɚ�����
Propagation Delay
Skew, maximum at 100MHz
ɚ�����QV��NP
ɚ�����QV��NP
Mutual capacitance
Capacitance unbalance (pair to ground)
Nom. 47 pF/m
ɚ�����S)��NP
Nominal velocity of propagation (NVP) 1RP�����
OD5024 OD 24AWG CAT5E UTP network cable, PVC UTP, PVC
OD5124 OD 24AWG CAT5E UTP network cable, LSZH UTP, LSZH
Insulation
Conductor
Jacket
35
NETWORK INFRASTRUCTURE
OD6000 UTP Series23AWG CAT6 UTP Network Cables
OverviewEach Cat6 UTP cable is performance optimized with 4 balancedtwisted pairs on 23 AWG insulated solid bare copper conductors.Each pair is separated by a center spline. OD Cat6 UTP cables areFRQVWUXFWHG�WR�FUHDWH�D�URXQG�DQG�ˊH[LEOH�FDEOH�IRU�HDV\�SXOOLQJDQG�VWULSSLQJ�RI�WKH�39&�MDFNHW�
Applications•••••
+RUL]RQWDO�:LULQJ�LQ�/$1IEEE 802.3: 10/100/1000 Base-TIEEE 802.5 16MBPower Over Ethernet PoE/PoE+IEEE 802.3af and IEEE 802.3at
Standards••••
$16,���7,$�����&��,62���,(&��������nd EdIEC 61156-5 2nd Ed(1��������(1���������������
Physical Characteristics
Available Options
Conductor 6ROLG�%DUH�&RSSHU
AWG 23
Conductor Diameter 0.56 (± 0.0005mm)
Insulation 39&��/6=+
Insulation Diameter Ø0.98mm
Jacket 39&��/6=+
Jacket Cover 39&��/6=+��%OXH
Outer Diameter 6.3 (± 0.3mm)
Weight ��NJ��NP
Machanical Characteristics
Minimum Bending Radius
Maximum Bending Radius
��[�'LDPHWHU
��[�'LDPHWHU
Temperature During Operation -20°C ~ +60°C
Temperature During Installation 0°C ~ +50°C
Electrical Characteristics
OD6423 2'���$:*�&$7��873�QHWZRUN�FDEOH��39& 873��39&
OD6123 2'���$:*�&$7��873�QHWZRUN�FDEOH��/6=+ 873��/6=+
Characteristic impedance (1-130 MHz)
Mean Characteristic impedance 100 Mhz
�����s�����ķ
�����s����ķ�
DC-loop resistance
Resistance unbalance
1RP������ķ��NP
ɚ�����
Propagation Delay
Skew, maximum at 100MHz
ɚ�����QV��NP
ɚ�����QV��NP
Mutual capacitance
Capacitance unbalance, maximum
1RP�����S)��NP
ɚ������S)��NP
Nominal velocity of propagation (NVP) ɚ������S)��NP
Attenuation @ 250Mhz 0RQ�����
Insulation
Conductor
-DFNHW
&HQWHU�6SOLQH
NETWORK INFRASTRUCTURE
36
OD6823F23AWG CAT6 FTP Network Cable
OverviewEach Cat6 FTP cable is performance optimized with 4balanced twisted pairs on 23 AWG insulated solid bare copperconductors. Each pair is separated by a center spline. OD Cat6)73�FDEOHV�DUH�FRQVWUXFWHG�WR�FUHDWH�D�URXQG�DQG�ˊH[LEOH�FDEOHfor easy pulling and stripping of the PVC jacket.
Applications•••••
Horizontal Wiring in LANIEEE 802.3: 10/100/1000 Base-TIEEE 802.5 16MBPower Over Ethernet PoE/PoE+IEEE 802.3af and IEEE 802.3at
Standards••••
ANSI / TIA 568-C.2ISO / IEC 11801 2nd EdIEC 61156-5 2nd EdEN 50173; EN 50288-3-1:2013
Physical Characteristics
Conductor Solid Bare Copper
AWG 23
Conductor Diameter 0.56 (± 0.0005mm)
Insulation LSZH
Insulation Diameter Ø0.98mm
Jacket LSZH
Jacket Cover LSZH: Blue
Outer Diameter 6.3 (± 0.3mm)
Weight 40kg /km
Machanical Characteristics
Minimum Bending Radius
Maximum Bending Radius
��[�'LDPHWHU
��[�'LDPHWHU
Temperature During Operation -20°C ~ +60°C
Temperature During Installation 0°C ~ +50°C
Conductor
Insulation
Jacket
Aluminium Foil
Electrical Characteristics
Characteristic impedance (1-130 MHz)
Mean Characteristic impedance 100 Mhz
�����s�����ķ
�����s����ķ�
DC-loop resistance
Resistance unbalance
1RP������ķ��NP
ɚ�����
Propagation Delay
Skew, maximum at 100MHz
ɚ�����QV��NP
ɚ�����QV��NP
Mutual capacitance
Capacitance unbalance, maximum
Nom. 50 pF /km
ɚ������S)��NP
Nominal velocity of propagation (NVP) ɚ������S)��NP
Attenuation @ 250Mhz 0RQ�����
37
NETWORK INFRASTRUCTURE
OD6823PE23AWG CAT6 UTP Outdoor PE Network Cable
Sheath (LLDPE)
Aluminium Tape
Plastic Seperator
Polyester Tape
Physical Characteristics
Conductor Solid Bare Copper
AWG 23
Conductor Diameter 0.57mm
Insulation HDPE
Insulation Diameter 1.02~1.04mm
Polyester Tap 25×0.035mm
Aluminium Tap 28x0.25mm
Plastic Separator 4.2x0.45mm
Sheath LLDPE
Sheath Thickness 1.4±0.1mm
Sheath Diameter 9.0±0.2mm
Color Black
Electrical Properties
Conductor Resistance (20°C)
Electrical Resistance Unbalance ( 20°C)
ɚ����ķ�����P
ɚ����
Insulation Resistance
Pair to Ground Capacitance Unbalance(0.8 KHz or 1KHz)
!�����0ķyNP
ɚ���S)����P
Mutual Capacitance of Pair ɚ���Q)����P
Standardsȧ��7,$�(,$����&��• ISO_IEC 11801ȧ��<'�7�����
Transmission Properties(Fluke Testing)
ZinFrequencyMHz
RL IL NEXT PS NEXT ELFEXT PS ELFEXT
ķ
100±15
dB/100m dB dB/100m dB/100m dB/100m dB/100m
1.0 ɚ��� ɛ���� ɛ���� ɛ���� ɛ�� ɛ����
4.0 ɚ��� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
8.0 ɚ��� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
10.0 ɚ��� ɛ���� ɛ���� ɛ���� ɛ���� ɛ��
���� ɚ��� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
20.0 ɚ��� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
25.0 ɚ��� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
31.25 ɚ���� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
���� ɚ���� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
100 ɚ���� ɛ���� ɛ���� ɛ���� ɛ�� ɛ��
155 ɚ���� ɛ���� ɛ���� ɛ���� ɛ���� ɛ����
250 ɚ���� ɛ���� ɛ���� ɛ���� ɛ�� ɛ����
NETWORK INFRASTRUCTURE
38
OD6023J&$7����$:*�-HOO\�ˉOOHG�2XWGRRU�873�1HWZRUN�&DEOH�
'HVFULSWLRQ
$SSOLFDWLRQV•••••
Horizontal Wiring in LANIEEE 802.3: 10/100/1000 Base-TIEEE 802.5 16MBPower Over Ethernet PoE/PoE+IEEE 802.3af and IEEE 802.3at
•••
Rated temperature of 75°C3URGXFW�6WDQGDUG�&HUWLˉFDWLRQ��8/�ˉOH�(������Flammability Tested
6WDQGDUGV••••
ANSI / TIA 568-C.2ISO / IEC 11801 2nd EdIEC 61156-5 2nd EdEN 50173; EN 50288-3-1:2013
3K\VLFDO�&KDUDFWHULVWLFV
&RQGXFWRU Solid Bare Copper
AWG 23
&RQGXFWRU�'LDPHWHU 0.57 (± 0.0005mm)
,QVXODWLRQ PE
)LOWHU PE
-HOO\�ˉOOHG Yes
-DFNHW PE
7KLFNQHVV 0.55 (± 0.05mm)
2XWHU�'LDPHWHU 6.3 (± 0.05mm)
5LS�&RUG Per request
Insulation
Conductor
FillerJelly Filled
Jacket
Rip
3HUIRUPDQFH)UHTXHQF\(MHz)
5HWXUQ�/RVV�G%�
$WWHQXDWLRQ�G%����P�
1(;7�G%�
ACR�G%�
1.00����8.00
10.0016.0020.0025.0031.2562.25
100.00200.00250.00
20.0023.01�����25.0025.0025.00���������������20.1118.0017.32
����3.695.265.897.51�������������15.3619.7828.97�����
�����65.2760.7559.30����������53.3351.88����������39.7838.33
)UHTXHQF\(MHz)
361(;7�G%�
(/1(;7�G%����P�
36(/)(;7�G%�
'(/$<�G%�
1.00����8.00
10.0016.0020.0025.0031.2562.25
100.00200.00250.00
72.3063.2758.7557.30�����52.7851.33���������������37.7836.33
68.0055.96�������������������������38.1032.0828.0021.98�����
65.0052.96���������������38.98�����35.1029.0825.0018.98�����
570.00552.00������������������������������������538.55537.60536.50536.28
39
NETWORK INFRASTRUCTURE
OD6123LCAT6 23AWG Stranded Fire Resistant ElevatorS/FTP Network Cable
Mechanical Characteristics
Applications
Description•••••
&$7��VWUDQGHG�ˉUH�UHVLVWDQW�HOHYDWRU�6�)73�FDEOH��$:*�VWUDQGHG�FRSSHU�FRQGXFWRU����������%DUH�FRSSHU�EUDLG�VKLHOG������FRYHUDJH$OXPLQLXP�IRLO������FRYHUDJH'RXEOH�39&�MDFNHW��ˉUH�UHVLVWDQFH�MDFNHW��UHG�FRORU�
•••••
+RUL]RQWDO�:LULQJ�LQ�/$1,(((��������������������%DVH�7,(((���������0%3RZHU�2YHU�(WKHUQHW�3R(�3R(�,(((������DI�DQG�,(((������DW�
Standards••••
$16,���7,$�����&��,62���,(&��������QG�(G,(&����������QG�(G(1��������(1���������������
2XWHU�-DFNHW
6WUDQGHG�&RSSHU�&RQGXFWRU
,QQHU�-DFNHW��)LUH�UHVLVWDQFH�
%UDLG�6KLHOG$OXPLQLXP�)RLO�6KLHOG
Bending Redius ZLWK�ORDG
ZLWKRXW�ORDG
Temperature GXULQJ�RSHUDWLRQ
GXULQJ�LQVWDOODWLRQ
Fire Load ��SDLU
Max. Tensile Load GXULQJ�RSHUDWLRQ
��[�'
��[�'
���r&�WR����r&
���r&�WR����r&
�RQ�UHTXHVW��0M�NP
���1
Construction
Conductor 6WUDQGHG�&RSSHU
AWG 23
Conductor Diameter ������s������PP�
Stranding �������
Insulation +'3(�����
Insulation Diameter �����
Outer Shield %DUH�&RSSHU
Coverage �����7DSH�$OXPLQLXP�)RLO�
Braid ���������
Outer Jacket 39&
Diameter º�����s�����PP�
Thickness ���PP
Color %ODFN
Inner Jacket )LUH�5HVLVWDQFH�39&
Diameter �����s�����PP�
Color 5HG
Fire Resistance Temperature ��r&
Pair �����FRUHV�
Electrical Properties at 20°C
DC loop resistance
Resistance unbalance
�
�
Insulation resistance
Capacitance
Capacitance unbalance
����9�
DW����0+]
�SDLU�WR�JRXQG�
Mean Charateristic #����0+]
ɚ���ķ�NP
ɚ��
ɛ����0[ķNP
1RP����Q)�NP
ɚ����S)�NP
���s�ķ
Nom. Velocity of Pro.
Propagation Delay
�
�
Delay Skew �
����F
ɚ���QV����P
ɚ��QV����P
Transfer Impedance DW���0+]
DW����0+]
ɚ��Pķ�P
ɚ�Pķ�P
Coupling Attenuation
DW����0+]
�
ɚ��Pķ�P
ɛ��G%
PatchcordStranded Network Patchcords
OverviewOptic Digital CAT6 UTP patch cord are designed to assure highperformance over longer distances. The patch cords arecomposed of 4-pairs, 24/7 AWG stranded conductors. The patchcords are terminated in factory with 8P8PC 50u" gold platedRJ45 plugs, boots are molded onto RG45 plug to ensure betterconnection. All patch cords are 100% tested in factory to ensureGigabit performance.
Features•••••••
10 Gigabit performanceFlexible stranded bare copper conductors patch cable2xRJ45 connector (TIA568-B coding)Comes with molded strain relief bootsComes in various colors100% factory terminated100% factory tested
Standards•••
ANSI / TIA 568-C.2ISO / IEC 11801 2nd Ed; EN 50173IEC 61935-2; IEC 60603-7
6HSFLˉFDWLRQV
RJ45 Plug
Insulation Resistance
8P8C 50u” gold plated
���Pķ��PD[��
Contact Resistance
Current Rating
���Pķ��PD[��
1.5Amps
DC Resistance ���ķ��PD[��
Withstanding Voltage 1000 VAX RMS @ 60Hz/1min
Ordering Information
Product code
ODPC
Category Type
XX
AWG
X
U/UTP or F/UTP
X
Color
XX
24AWG26AWG
46
--
U/UTPF/UTP
UF
--
GreyGreenRedBlueYellowPurple
GYGNRDBLYLVL
------
PVC / LSZH
X
PVCLSZH
PL
123
90
--
Length
X
1meter2meter3meter
90meter
---
-
CAT5eCAT6CAT6a
50606A
---
~
ExampleODPC604UGYP-3 = CAT6 24AWG U/UTP, Grey color patch cord with PVC jacket in 3 meter length.
Basic Info CAT5e & CAT6 U/UTP, common with 24AWG stranded copper.CAT5e & CAT6 F/UTP, common with 26AWG stranded copper.CAT6a U/FTP & S/FTP, common with 26AWG stranded copper.
NETWORK INFRASTRUCTURE
40
FaceplateClassic Multi Gang Faceplates (White)
Overview2')3�*�VHULHV�IDFHSODWHV�DUH�D�SHUIHFW�ˉWWLQJ�IRU�FDEOHV�WKDWKDYH�EHHQ�UXQ�EHWZHHQ�URRPV�EHQHDWK�ˊRRUV�DQG�EHKLQGZDOOV��7KH�ZLUHV�FDQ�EH�DWWDFKHG�WR�WKH�NH\VWRQH�MDFN�DW�WKHEDFN�RI�WKH�VRFNHWV�LQ�MXVW�D�IHZ�PLQXWHV��XVLQJ�DQ�,'&WHUPLQDWLRQ�WRRO�ZKLFK�LV�D�VPDOO�VFDOH�WHFKQLFLDQȠV�WRRO�IRUJXLGLQJ�ZLUHV�LQWR�VPDOO�VRFNHWV�
Features••
•••••
6XSSOLHG�ZLWK�������NH\VWRQH�5-����PRGXODU�VRFNHWV&DQ�EH�XVHG�RYHU�GLVWDQFHV�XS�WR����P����IW�IRUQHWZRUNLQJ�SXUSRVHV7,$�(,$�����$�%�873�ZLULQJ�OD\RXW,'&�WHUPLQDWLRQ�SRLQWV)LWV�D�VWDQGDUG�VLQJOH�EDFN�ER[)L[LQJ�VFUHZV�VXSSOLHG6WDQGDUGV���52+6�&RPSOLDQW�DQG�&(�$SSURYHG
6SHFLˉFDWLRQV
Type
Advantage
Faceplate
:LWK�6KXWWHU
3RUW
&RORU
���������
:KLWH
&RYHU�0HWHULDO $%6
Size ���[���PP
$FFHVVRULHV ��VFUHZV
Net Weight ��J
$YDLODEOH�2SWLRQV
ODFP0100G ��*DQJ�FODVVLF�5-���IDFHSODWH ��*DQJ
ODFP0200G ��*DQJ�FODVVLF�5-���IDFHSODWH ��*DQJ
ODFP0400G ��*DQJ�FODVVLF�5-���IDFHSODWH ��*DQJ
41
NETWORK INFRASTRUCTURE
Faceplate SystemFaceplate Frames
6SHFLˉFDWLRQV
7HUPLQDWLRQ
)LQLVK
4 Screws Terminal
White Plastic
'LPHQVLRQV��+�[�:� 86mm x 86mm
2UGHU�,QIRUPDWLRQ
ODFPI01 Single port faceplate frame, UK frame (86x86)
6SHFLˉFDWLRQV
7HUPLQDWLRQ
)LQLVK
4 Screws Terminal
White Plastic
'LPHQVLRQV��+�[�:� 86mm x 86mm
2UGHU�,QIRUPDWLRQ
ODFPI02 Dual port faceplate frame, UK frame (86x86)
6SHFLˉFDWLRQV
7HUPLQDWLRQ
)LQLVK
4 Screws Terminal
White Plastic
'LPHQVLRQV��+�[�:� 86mm x 86mm
2UGHU�,QIRUPDWLRQ
ODFPI03 Triple port faceplate frame, UK frame (86x86)
ODFPI01��[��PP�6LQJOH�3RUW�)DFHSODWH�)UDPH
ODFPI02��[��PP�'XDO�3RUW�)DFHSODWH�)UDPH�
ODFPI03��[��PP�7ULSOH�3RUW�)DFHSODWH�)UDPH
NETWORK INFRASTRUCTURE
42
Snap-In ModuleNetwork & Fiber Snap-In Modules
ODIRJ
••
Fits 10G Surface Mount BoxRoHS Complaint
1” RJ45 Keystone Jack Snap-In Module50.1
24.9
14.6
7.79.8
16.2
ODIRJ 1” RJ45 keystone jack snap-in module, Snap-in, RJ45 keystone jack
ODILCSC
••
Fits Fiber Surface Mount BoxRoHS Complaint
1” Snap-In Module, Single Keystone Adapter
ODILCSC �ȣ�6&��/&�ˉEHU�VQDS�LQ�PRGXOH�� Snap-in, SC/LC Fiber
ODI01
••
Fits Surface Mount BoxRoHS Complaint
1” Snap-In Blank Module
ODI01 1” Snap-in blank module Snap-in, Blank
50.1
24.7
12.113.1
9.4
9.6
13.4
24.7
50.19.6
58 43
NETWORK INFRASTRUCTURE
Keystone JackRJ45 Network Keystone Jacks
OverviewThe OD eystone jacks are designed to meet the industrystandard TIA/EIA 568-C.2 requirements, it works inconjunction with the cables to go faceplates and surfaceboxes or any standard keystone and angled multimediafaceplate or patch panel. Each keystone jack includes110-type IDC straight-back termination with strain reliefcaps, and comes with standard gold plating on the jackcontacts.
Features•••••••••
Easy to use, modular CAT6 RJ45 Keystone jack for ethernet.110 type IDC punch down connectors90 degree wire connection.Can be used with keystone wall plate or patch panel.Standard keystone sizeColor coded wiring diagram next to wire clips.568A and B compliant.UL listed.Includes clear plastic termination cap.
Standards
Available Options
••••
ANSI / TIA 568-C.2ISO / IEC 11801 2nd EdIEC 60603-7-[4, 5]EN 50173-1; EN 50173-2
6HSFLˉFDWLRQV
Type
Termination
Panel-type Unshielded RJ-45 (8P8C)
110/KRONE IDC vertical punchdown
AWG Wire
Support Wiring
22 - 26AWG Wires
Dual T568A & T568B
Applications Any unloaded keystone faceplate or patch panel
&HUWLˉFDWLRQV UL listed; Complies with FCC Part 68
Color White
Weight 0.3lbs
Contact Surface Finish 50u” gold plated over contact area
IDC Surface Finish Tin plated
ODKJ6806P CAT6a unshielded keystone jack CAT6a, unshielded
ODKJ6006P CAT6 unshielded keystone jack CAT6, unshielded
ODKJ6006FP CAT6 FTP unshielded keystone jack CAT6, FTP, unshielded
ODKJ5003S CAT5e shielded keystone jack CAT5e, shielded
ODKJ5003P CAT5e unshielded keystone jack CAT5e, unshielded
ODKJ6806S CAT6a shielded keystone jack CAT6a, shielded
CAT5e Unshielded Jack
Shielded CAT6a Jack Unshielded CAT6 Jack
Unshielded CAT6a Jack
CAT5e Shielded Jack
NETWORK INFRASTRUCTURE
44
ODRBRJ45 Connector Rubber Boots Network CableEnds Plug
Overview5XEEHU�ERRWV�LPSURYH�WKH�LGHQWLˉFDWLRQ�DQG��GXUDELOLW\�RI�SDWFKFRUGV�WHUPLQDWHG�ZLWK�WKH�LQGXVWU\�VWDQGDUG�5-���SOXJ��7KH\�FDQXVHG�ZKHQ�FUHDWLQJ�D�QHWZRUN�FDEOH�DQG�FRPH��LQ�D�UDQJH�RI�FRORUVWR�PDWFK�WKH�FDEOH�XVHG��2XU�ˊH[LEOH�UXEEHU�ERRWV�HQVXUH�HDVH�RIODWFK�GLVHQJDJHPHQW�
Features•••
6WUDLQ�UHOLHI�PRXOGHG�ERRWV�IRU�5-���FRQQHFWLRQV)RU�TXLFN�DQG�HDV\�LGHQWLˉFDWLRQ�RI�\RXU�QHWZRUN�FDEOHV$SSO\�GXULQJ�FDEOH�DVVHPEO\�RQ�&DW�H�RU�&DW��FDEOHV
6SHFLˉFDWLRQV
Material
Moulding Length
39&�3ODVWLF
����PP
Moulding Width (plug end)
Moulding Width (cable end)
����PP
�P
Cable Aperture Width ���PP
Rubber Thickness ���PP
45
NETWORK INFRASTRUCTURE
ODRJ ConnectorRJ45 Modular Plug 8-Pin Network Connectors
Features•
•••
Gold plated leads for better data transmitting andhigher signal strengthSuitable for 26-23AWG network cableSingle piece constructionUL1863 standard and RoHS Compliant
Available Options
ODRJ1103 CAT3 unshielded RJ11 modular plug connector CAT3
ODRJ4569S CAT6 FTP RJ45 network modular plug connector CAT6, FTP
ODRJ4579S CAT7 STP RJ45 network modular plug connector CAT7, STP
ODRJ4566 CAT6 6Mil unshielded RJ45 network modular plug connector CAT6, 6Mil
ODRJ4563 CAT6 3Mil unshielded RJ45 network modular plug connector CAT6, 3Mil
ODRJ6688 CAT6 toolless unshielded modular plug connector CAT6, Toolless
ODRJ6689A CAT6a toolless unshielded modular plug connector CAT6a, Toolless
ODRJ4566PT CAT6 RJ45 Pass Through Connector 6 Mil CAT6, Pass Through
6SHFLˉFDWLRQV
Current Rating 1.5 A maximum
Contact Blade Phosphor bronze plated with 50u” gold over 100u’’ nickel undercoat
ELECTRICAL CHARACTERISTICS
Plug Type Modular Plug
PHYSICAL CHARACTERISTICS
Characteristic Impendence 100 Ohms
Insulation Resistance 100 Mohms Min
Contact Resistance 20 Mohms Max
Voltage Rating 30 VAC maximum
MECHNICAL CHARACTERISTICS
Cable Retention Force 40 lbs Max
Max Insertion and Withdrawal Force 22 N
Humidity 10% to 90% R.H.
WIRE RANGE
Conductor Diameters 0.41mm to 0.52mm (26AWG to 23AWG)
Conductor Type Solid; Stranded
Insulation Diameters 0.98mm to 1.05mm
Cable Diameters 5.0mm to 7.0mm
APPLICABLE STANDARDS
8/�6SHFLˉFDWLRQ UL 1863
(,$�6SHFLˉFDWLRQ EIA-364
EU RoHS Compliant (Y/N) Y
NETWORK INFRASTRUCTURE
46
Network Patch Panel24-Ports Full Loaded UTP Patch Panels
OverviewThe OD 24-ports patch panels offer cost-effective solutionto achieve high performance that exceeds ANSI/TIA-568Category CAT5e and CAT6 standards. This horizontal patchpanel is designed with rear 110 IDC's for quick and easypunch-down termination. It also comes integrated with auniversal label for either 568-A or B wiring. Packageincludes #12 rack screws.
Features•
•
•
•••••
Provides excellent performance for data networks requiringmaximum speed and bandwidthEnhanced crosstalk cancellation reduces return loss andimproves performance by rejecting noise and unwanted signalsExceeds ANSI/TIA-568-C.2 CAT5e & CAT6 connecting hardwarerequirementsEngineering to provide 110 IDC termination reducing installation timeIncludes both T568A and T568B color wiring diagramsBackwards compatible to all lower rated category components'HVLJQHG�WR�ˉW�DOO�VWDQGDUG�����UDFNV�DQG�FDELQHWV1 rack mount space (RMS)
Available Options
ODPP5e24 CAT5e 24-port fully loaded UTP punch-down network patch panel CAT5e, 24-port
ODPP6024 CAT6 24-port fully loaded UTP punch-down network patch panel CAT6, 24-port
ODPP6024EM CAT6 24-port empty UTP punch-down network patch panel CAT6, 24-port, Empty
Performance 6SHFLˉFDWLRQV
Wiring
IDC Type
TIA 568 A/B
110
Insertion Force
Plug Insertion Life
ɚ���1
800 times insertion (RJ45)
Wire Size Capacity 22 - 26 AWG solid wire
Capacity
Front Connection
24 connectors (RJ45)
Flush
Termination Area
Material
Rear
Steel
Color Black
Size 1U
47
NETWORK INFRASTRUCTURE
ODCM1UM1U Horizontal Cable Management
Features••••
•
19" 1U metal cable management AMP styleSuitable for 19 inch standard cabinets and wall mountWhole body is made of carbon steel, 1.20mm of thnikness(IIHFWLYH�LQ�VLPSOLˉFDWLRQ�DQG�VWDQGDUGL]DWLRQ�RI�FURVVwiring arrangementNice appearence, high quality
Available Options
ODCM1UM ��ȣ��8�+RUL]RQWDO�&DEOH�0DQDJHPHQW 19” 1U
NETWORK INFRASTRUCTURE
48
INSTALLATION CABLES03
INSTALLATION CABLES
50
ODRG59815*�����$:*���ķ�&RD[LDO�&DEOH
'HVFULSWLRQ
$SSOLFDWLRQV• Carry baseband video in closed-ciruit television.
•••••
5*�����$:*���ķ�FRD[LDO�FDEOH20AWG 0.812mm bare copper covered steel conductorFoam polyethylene insulationFoil & aluminium braid shieldPVC jacket
Outer Jacket
Outer Shield
Foil Shield
Insulation
Inner Conductor
3K\VLFDO�&KDUDFWHULVWLFV��2YHUDOO�
,QQHU�&RQGXFWRU Bare Copper Covered Steel
AWG 20
&RQGXFWRU�'LDPHWHU 0.812mm
6WUDQGLQJ Solid
,QVXODWLRQ Foam Polyethylene
,QVXODWLRQ�'LDPHWHU 3.65mm
2XWHU�6KLHOG Aluminium braid
&RYHUDJH
)RLO�6KLHOG
65%
Aluminium Foil
2XWHU�-DFNHW PVC - Polyvinyl Chloride
2YHUDOO�&DEOH
2YHUDOO�1RP��'LDPHWHU 6.0mm
0HFKDQLFDO�&KDUDFWHULVWLFV��2YHUDOO�
2SHUDWLQJ�7HPSHUDWXUH�5DQJH -30°C ~ +60°C
1RQ�8/�7HPSHUDWXUH�5DWLQJ 60°C
%XON�&DEOH�:HLJKW 43 Kg/Km
0D[��5HFRPPHQGHG�3XOOLQJ�7HQVLRQ 243 N
0LQ��%HQG�5DGLXV�0LQRU�$[LV 60.2 mm
6XLWDELOLW\ Indoor
3OHQXP��<�1� N
(OHFWULFDO�&KDUDFWHULVWLFV��2YHUDOO�
1RP��&KDUDFWHULVWLF�,PSHGDQFH
,PSHGDQFH ��ķ
1RP��,QGXFWDQFH
,QGXFWDQFH 0.29529µH/m
1RP��&DSDFLWDQFH�&RQGXFWRU�WR�6KLHOG
&DSDFLWDQFH 53.14pF/m
1RPLQDO�9HORFLW\�RI�3URSDJDWLRQ
93 83%
1RPLQDO�'HOD\
'HOD\ 4.2653ns/m
1RP��&RQGXFWRU�'&�5HVLVWDQFH
'&5�#���r& �����ķ�NP
1RPLQDO�2XWHU�6KLHOG�'&�5HVLVWDQFH
'&5�#���r& ������ķ�NP
0D[��2SHUDWLQJ�9ROWDJH���1RQ�8/
9ROWDJH 300 V RMS
51
INSTALLATION CABLES
ODRG5973F5*�����$:*���ķ�6WUDQGHG�&RD[LDO�&DEOH
'HVFULSWLRQ
$SSOLFDWLRQV• Uses for indoor environment which is required moreˊH[LELOLW\�DSSOLFDWLRQV
•••••
5*�����$:*���ķ�VWUDQGHG�FRD[LDO�FDEOH���$:*�VWUDQGHG���[����������EDUH�FRSSHU�FRQGXFWRU)RDP�SRO\HWK\OHQH�LQVXODWLRQ%DUH�FRSSHU�EUDLG�VKLHOG������FRYHUDJH�39&�MDFNHW
3K\VLFDO�&KDUDFWHULVWLFV��2YHUDOO�
,QQHU�&RQGXFWRU %DUH�&RSSHU�&RYHUHG�6WHHO
AWG 22
&RQGXFWRU�'LDPHWHU �����PP
6WUDQGLQJ �[��
,QVXODWLRQ )RDP�3RO\HWK\OHQH
,QVXODWLRQ�'LDPHWHU ������PP
2XWHU�6KLHOG %UDLG�%DUH�&RSSHU
&RYHUDJH
2XWHU�-DFNHW
���
39&���3RO\YLQ\O�&KORULGH
2XWHU�-DFNHW�&RORU Red
2YHUDOO�&DEOH
2YHUDOO�1RP��'LDPHWHU �����PP
0HFKDQLFDO�&KDUDFWHULVWLFV��2YHUDOO�
2SHUDWLQJ�7HPSHUDWXUH�5DQJH ���r&�a����r&
1RQ�8/�7HPSHUDWXUH�5DWLQJ ��r&
%XON�&DEOH�:HLJKW �������.J�.P
0D[��5HFRPPHQGHG�3XOOLQJ�7HQVLRQ ��������1
0LQ��%HQG�5DGLXV�0LQRU�$[LV �������PP
6XLWDELOLW\ Indoor
3OHQXP��<�1� 1
(OHFWULFDO�&KDUDFWHULVWLFV��2YHUDOO�
1RP��&KDUDFWHULVWLF�,PSHGDQFH
,PSHGDQFH ��ķ
1RP��,QGXFWDQFH
,QGXFWDQFH �������w+�P
1RP��&DSDFLWDQFH�&RQGXFWRU�WR�6KLHOG
&DSDFLWDQFH �������S)�P
1RPLQDO�9HORFLW\�RI�3URSDJDWLRQ
93 ���
1RPLQDO�'HOD\
'HOD\ ������QV�P
1RP��&RQGXFWRU�'&�5HVLVWDQFH
'&5�#���r& ������ķ�NP
1RPLQDO�2XWHU�6KLHOG�'&�5HVLVWDQFH
'&5�#���r& ������ķ�NP
0D[��2SHUDWLQJ�9ROWDJH���1RQ�8/
9ROWDJH ����9�506
1RP��$WWHQXDWLRQ
2XWHU�-DFNHW
2XWHU�6KLHOG
,QVXODWLRQ
Inner Conductor
������������������������
�����������������������������������������������������������
)UHTXHQF\��0+]� $WWHQXDWLRQ��G%����P�
INSTALLATION CABLES
52
ODRG6102RG6 18AWG 75ķ Coaxial Cable
Description
Applications• Used for closed-circuit television, satellite television and
cable modems.
•••••
5*����$:*���ķ�FRD[LDO�FDEOH18AWG 1.02mm bare copper covered still conductorFoam polyethylene insulationFoil & aluminium braid shieldPVC jacket
Outer Jacket
Outer Shield
Foil Shield
Insulation
Inner Conductor
Physical Characteristics (Overall)
Inner Conductor Bare Copper Covered Steel
AWG 18
Conductor Diameter 1.02mm
Stranding Solid
Insulation Foam Polyethylene
Insulation Diameter 4.57mm
Outer Shield Aluminium braid
Coverage
Foil Shield
90%
Aluminium Foil
Outer Jacket PVC - Polyvinyl Chloride
Overall Cable
Overall Nom. Diameter 6.90mm
Mechanical Characteristics (Overall)
Operating Temperature Range -30°C ~ +60°C
Non-UL Temperature Rating 60°C
Bulk Cable Weight 47.1 Kg/Km
Max. Recommended Pulling Tension 283 N
Min. Bend Radius/Minor Axis 69.34 mm
Suitability Indoor
Plenum (Y/N) N
Electrical Characteristics (Overall)
Nom. Characteristic Impedance
Impedance ��ķ
Nom. Inductance
Inductance 0.29529µH/m
Nom. Capacitance Conductor to Shield
Capacitance 53.2pF/m
Nominal Velocity of Propagation
VP 82%
Nominal Delay
Delay 4.2653ns/m
Nom. Conductor DC Resistance
DCR @ 20°C �������ķ�NP
Nominal Outer Shield DC Resistance
DCR @ 20°C ������ķ�NP
Max. Operating Voltage - Non-UL
Voltage 300 V RMS
53
INSTALLATION CABLES
ODRG6102PERG6 18AWG 75ķ Outdoor Coaxial Cable
Description
Applications• Uses for high frequency MATV or HD video signal applications
•••••
RG6 18AWG 75Ohm Coaxial Cable18AWG 1.016mm solid bare copper conductorFoam high density polyethylene insulationFoil & aluminium braid shield (95% coverage)PE jacket
Outer Jacket
Outer Shield
Foil Shield
Insulation
Inner Conductor
Physical Characteristics (Overall)
Inner Conductor Bare Copper Covered Steel
AWG 18
Conductor Diameter 1.016mm
Stranding Solid
Insulation Hi-Density Polyethylene
Insulation Diameter 4.572mm
Outer Shield Aluminium
Coverage
Foil Shield
95%
Aluminium Foil
Outer Jacket PVC - Polyvinyl Chloride
Overall Cable
Overall Nom. Diameter 6.96mm
Dielectric Strength 1.0kV/min
Impedence ��ķ
SRL (dB, 0-300MHz) >=20
Capacitance 53.1pF/m
Conductor DCR @ 20°C <=102ohms/km
Velocity of Propagation >=82%
Mechanical Characteristics (Overall)
Operating Temperature Range -30°C ~ +60°C
Non-UL Temperature Rating 60°C
Bulk Cable Weight 18.60 kg/305m
Max. Recommended Pulling Tension 31.30 kg
Min. Bend Radius/Minor Axis 69.85 mm
Suitability Indoor / Outdoor
Plenum (Y/N) N
Electrical Characteristics (Overall)
555211250400600750870
10001300145017502150260028323000
0.581.6
3.053.3
4.155.1
5.656.116.557.467.898.749.69
10.7611.5111.84
Frequency (MHz) Attenuation (dB/100ft)
INSTALLATION CABLES
54
ODRG11165*�����$:*���ķ�&RD[LDO�&DEOH
'HVFULSWLRQ
$SSOLFDWLRQV• Used for high frequency MATV or HD video signal applications
•••••
RG11 14AWG 75Ohm Coaxial Cable14AWG 1.63mm solid bare copper conductorGas-injected foam polyethylene insulation100% Aluminium foil & 60% copper braid shieldPVC jacket
3K\VLFDO�&KDUDFWHULVWLFV��2YHUDOO�
,QQHU�&RQGXFWRU Bare Copper Covered Steel
AWG 14
&RQGXFWRU�'LDPHWHU 1.63mm
6WUDQGLQJ Solid
,QVXODWLRQ Gas-injected FPE
,QVXODWLRQ�'LDPHWHU 7.11mm
2XWHU�6KLHOG Tape/Briad Copper
&RYHUDJH
)RLO�6KLHOG
60%
Aluminium Foil
2XWHU�-DFNHW PVC - Polyvinyl Chloride
2XWHU�-DFNHW�7KLFNQHVV
2YHUDOO�&DEOH
1.0mm
2YHUDOO�1RP��'LDPHWHU 10.0mm
0HFKDQLFDO�&KDUDFWHULVWLFV��2YHUDOO�
2SHUDWLQJ�7HPSHUDWXUH�5DQJH -40°C ~ +80°C
1RQ�8/�7HPSHUDWXUH�5DWLQJ 80°C
%XON�&DEOH�:HLJKW 60kg/km
0D[��5HFRPPHQGHG�3XOOLQJ�7HQVLRQ 1200N
0LQ��%HQG�5DGLXV�0LQRU�$[LV 115mm
,QVXODWLRQ�'LDPHWHU Indoor
3OHQXP��<�1� No
0HFKDQLFDO�&KDUDFWHULVWLFV��2YHUDOO�
1RP��&KDUDFWHULVWLFV�,PSHGDQFH ����ķ
1RP��&DSDFLWDQFH�&RQGXFWRU�WR�6KLHOG 53.1pF/m
1RP��9HORFLW\�RI�3URSDJDWLRQ 83%
1RP��'HOD\� 4.065ns/m
1RP��&RQGXFWRU�'&�5HVLVWDQFH�#����'HJ�& ����ķ�NP
1RP��2XWHU�6KLHOG�'&�5HVLVWDQFH�#����'HJ�& ����ķ�NP
0LQ��6WUXFWXUDO�5HWXUQ�/RVV���a����0+]� 21dB
0LQ��6WUXFWXUDO�5HWXUQ�/RVV�����a�����0+]� 18dB
0HFKDQLFDO�&KDUDFWHULVWLFV��2YHUDOO�
2SHUDWLQJ�7HPSHUDWXUH�5DQJH -30°C ~ +60°C
1RQ�8/�7HPSHUDWXUH�5DWLQJ 60°C
%XON�&DEOH�:HLJKW 47.1 Kg/Km
0D[��5HFRPPHQGHG�3XOOLQJ�7HQVLRQ 283 N
0LQ��%HQG�5DGLXV�0LQRU�$[LV 69.34 mm
6XLWDELOLW\ Indoor
3OHQXP��<�1� N
Outer Jacket
Braid Shield
Aluminium Foil Shield
Insulation
Inner Conductor
24AWG
Isulation HDPE, 0.2mm
Outer Sheath Polyvinyl Chloride (PVC), 0.6mm
Sheath Color White
Stripping Nylon stripping cord
Max voltage 50V RMS
Current rating 1Amp
Operating Temperature -10ºC to +70ºC
BS Standards -
OD4702TC4 Core 7/0.2mm TC Alarm Cable
Description
ApplicationsFlexible cable used for the wiring of security systems,access control, burglar alarms and other low voltageapplications.
'HˉQLWLRQ4 core Tinned Copper cable are designed mainly for signal transmittion of burglar alarm systems,it also widely used on security systems, access control and other low voltage applications.
Conductor Rating4core with 7x0.2mm stranded conductors covered by High-density polyethylene insulations.
Construction••
PVC white sheath jacket with stripping cord & HDPE insulation covered 4 core conductors.100 meters (328 feet) per roll packaging.
7 stranded conductors of 0.20 mm with PVC insulation and39&�VOHHYH�LQ�ZKLWH��*RRG�ˊH[LELOLW\�FRPELQHG�ZLWKrobustness and strong nylon stripping cord.
Physical Characteristics (Overall)
Inner Conductor Tinned Copper
AWG 24
Stranding 7x0.2mm
Insulation HDPE
Insulation Diameter Ø 1.0 ± 0.05mm
Insulation Thickness 0.2mm
Outer Jacket
Jacket Diameter
PVC
Ø 4.5 ± 0.2mm
Jacket Thickness 0.6mm
WhiteSheath Color
Voltage Rating 50V
Temperature Rating -10°C ~ +70°C
Red, Blue, Yellow, Black,GHQWLˉFDWLRQ�&RORU
Core Material Tin Copper
Stranding 7 x 0.2mm
Gauge
6SHFLˉFDWLRQV
Outer Jacket
Stripping Cord
Insulation
Stranded Conductor
55
INSTALLATION CABLES
INSTALLATION CABLES
56
ODTF21352C x 23/0.16 Twin Flat Power Cable
Description
Applications��FRUH�WZLQ�ˊDW�FDEOH�DUH�XVHG�PDLQO\�IRU�SRZHU�DQGOLJKWLQJ�FLUFXLWV��ERWK�GRPHVWLF�DQG�LQGXVWULDO�DSSOLFDWLRQV�
��[����PP�EDUH�FRSSHU�LQQHU�FRQGXFWRUV�ZLWK���FRORUV39&�LQVXODWLRQ��EURQZQ�DQG�EOXH���7KH�WZLQ�ˊDW�39&�EODFNRXWHU�MDFNHW�GHVLJQ�SURYLGHV�PRUH�GXUDEOLW\�DQG�ˊH[LELOLW\�
2XWHU�6KLHOG
,QVXODWLRQ
,QQHU�&RQGXFWRU
Physical Characteristics (Overall)
Inner Conductor %DUH�&RSSHU
Stranding ��[����PP
Insulation PVC
Insulation Diameter ������s����PP
Insulation Thickness )RDP�3RO\HWK\OHQH
Insulation Diameter ���PP
Insulation Color %URZQ��%OXH
Outer Jacket
Jacket Diameter
PVC
����s�����[���s�����PP
Average Thickness ���P
%ODFNColor
Physical Characteristics (Overall)
Core Material %DUH�&RSSHU
Conductor ��[����PP
Guage
Insulation 39&������s����PP
Outer Jacket 39&������s����PP�[���s�����PP
Jacket Color %ODFN
Stripping NA
Insulation Color
Operating Temperature
%URZQ��%OXH
���|&�WR����|&
BS Standards -
7ZLQ�ˊDWV�DUH�PDGH�XS�RI�WZR�39&�LQVXODWHG�FRQGXFWRUV�RQO\��ERWK�W\SHV�FRYHUHG�ZLWKD�EODFN�39&�6KHDWKLQJ��7KHVH�FDEOH�DUH�XVHG�PDLQO\�IRU�SRZHU�DQG�OLJKWLQJ�FLUFXLWV�ERWK�GRPHVWLF�DQG�LQGXVWULDO�DSSOLFDWLRQV�
'HˉQLWLRQ
��������9ROWV�ZLWK�D�PD[LPXP�RSHUDWLQJ�WHPSHUDWXUHRI���r&�
Voltage Rating
ȧ�&RQGXFWRUV�DUH�PDGH�XS�RI�VRIW�DQQHDOHG�FRSSHU���DQG�FDQ�EH�VWUDQGHG�RU�VROLG�ȧ�%RWK�FRUHV�DQG�LQ�WKH�SUHVHQFH�RI�DQ�HDUWK���FRQGXFWRU��DUH�DOO�FRYHUHG�ZLWK�D�EODFN�39&�VKHDWKLQJ�
Construction
57
INSTALLATION CABLES
ODRS422424AWG Multi Conductor EIA-485 Cable
Description
Applications• Low capacitance Full Duplex, RS-485 High Speed Data
•••••
24AWG (7/0.2) TC conductorHDPE ID1.8, twisted pair2 cores twisting, total 2 pairs (4 cores)Color: Blue/White, White/BlueBlack PVC jacket
Physical Characteristics (Overall)
Inner Conductor Tinned Copper
AWG 24
Stranding 7/0.2
Core 4
Drain Wire Tinned Copper
Insulation HDPE ID1.8
Insulation Diameter 0.6mm
Outer Shield
Coverage
Braid TC Copper
90%
Tape Aluminium Foil
100%Coverage
Outer Jacket PVC - Polyvinyl Chloride
Outer Jacket Thickness 0.8mm
Pair Color Blue/White, White/Blue
Mechanical Characteristics (Overall)
Operating Temperature Range -30°C ~ +60°C
Non-UL Temperature Rating 80°C
Bulk Cable Weight 53.575kg/km
Max. Recommended Pulling Tension 321.605N
Min. Bend Radius/Minor Axis 63.500 mm
Suitability Indoor
Plenum (Y/N) No
Electrical Characteristics (Overall)
Nom. Characteristic Impedance
Impedance ���ķ
Nom. Capacitance Conductor to Shield
Capacitance 41.9968pF/m
Nominal Velocity of Propagation
VP 66%
Nominal Delay
Delay 5.2496ns/m
Nom. Conductor DC Resistance
DCR @ 20°C ������ķ�NP
Nominal Outer Shield DC Resistance
DCR @ 20°C �������ķ�NP
21.dBMin. Structural Return Loss (5-950MHz)
Min. Structural Return Loss (950-3000MHz) 18dB
1.000MHzNom. Attenuation Frequency (MHz)
Nom. Attenuation (dB/100m) 1969dB/100m
300V RMS Type CMMax. Operation Voltage - UL
300V RMS AWM2919
2.1A per conductorMax. Recommended Current
25° ambient
Outer Jacket
Braid Shield
Aluminium Foil
Insulation
Inner Conductor
Drain Wire
EQUIPMENT RACKS04
GPX82-10Large Capacity Cold-rolled Steel Distributor Frame
*3;������SURYLGHV�ˊH[LEOH�FDEOLQJ�DFFHVV��H[SDQGDEOH�IUDPHFRQFHSW��LQWHJUDWHG�FDEOH�PDQDJHPHQW�DQG�D�IXWXUH�SURRI�PRGXODUGHVLJQ�ZLWK�WKH�KLJKHVW�WHUPLQDWLRQ�FDSDFLW\�SRVVLEOH�DQG�VXSHULRUFDEOH�PDQDJHPHQW��+LJK�GHQVLW\�VLGH�DFFHVV�W\SH�RI�SDWFK�SDQHO�LVDOVR�GHVLJQHG�WR�ˉW�D�YDULHW\�RI�WHUPLQDWLRQ��VSOLFH��DQG�VWRUDJHDSSOLFDWLRQV�
Overview
•
•••••
•
•
•
••
•
••
7KLFNQHVV�RI�VWHHO��IURQW�GRRUV�DQG�UHDU�SDQHO�����PP��RWKHUSDUWV�����PP/RFN�DW�WKH�IURQW�GRRU(QKDQFHG�YLVXDO�DSSHDUDQFH+LJKO\�VWDEOH�DQG�ULJLG�FRQVWUXFWLRQ6WDQGDUG���ȣ��(76,�LQVWDOODWLRQV'HVLJQHG�WR�EH�XVHG�WRJHWKHU�ZLWK�KLJK�GHQVLW\�VLGH�DFFHVVW\SH�SDWFK�SDQHOV0D[LPXP�ˉEHU�GHQVLW\�RI������SRUWV��VSOLFH��SDWFK��DQGVXSHULRU�FDEOH�PDQDJHPHQW6SHFLDO�FDEOH�JODQGV�WR�ˉ[�WKH�PD[LPXP�QXPEHU�RI�EXQGOHFDEOHV�RQ�WKH�JURXQG6ORW�W\SH�FDEOH�JXLGH�FRPSDUWPHQWV�WR�IHHG�WKH�PRGXOHV�YLDPLQLˊH[�WXEHV:LGH�UDQJH�RI�VSOLFH��SDWFK�DQG�FDEOH�VWRUDJH�RSWLRQV%HQG�UDGLXV�SURWHFWLRQ�RI����PP�WKURXJKRXW�HQWLUH�IUDPHDQG�DOO�PRGXOHV,QWHUFKDQJHDEOH�FDVVHWWHV�IRU�YDULRXV�FDEOH�WXEH�FRXQWVDQG�FRQQHFWRU�VW\OHV$FFHSWV�:'0�DQG�VSOLWWHU�FDVVHWWHV,QWHJUDO�SDWFK�FRUGV�PDQDJHPHQW
Features
•••
���2'8�/���3DWFK�3DQHOV�LQ����8�)UDPH6&�/&�LQWHUIDFHV�DYDLODEOH7KH�)UDPHV�DUH�FRPSOLDQW�WR�7HOFRUGLD�6SHFLˉFDWLRQ*5�����FRUH
Density Info
5DFN�0RXQW�3DWFK�3DQHO�2'8�/��
6SHFLˉFDWLRQV
Dimension (H*W*D) ����PP ���PP ���PP
&ROG�UROOHG�VWHHO��3RZGHU�FRDWHG
5$/�����
����NJ���HPSW\
�����3RUW��6SOLFH��3DWFK�
Material
Color
Maximum Port Capacity
Weight
�� �8�3DWFK�3DQHO������3RUWV�
*5�����FRUH�RI�7HOFRUGLD�6SHFLˉFDWLRQ
��r&�a���r&
����DW���r&
Maximum Subracks Allowed
Compliance
Humidity
Temperature
��N3D�ȝ����N3DAir Pressure
59
EQUIPMENT RACKS
PG-WM SeriesWall Mount Distribution Frame
Available Models
•••••
•
•
Variety of heightsReliable welded main frameVented top and bottomComply with 19” wall mount standardFront lockable door with either Perspex withframe or PerforatedSuitable for stand alone or provided forstanding installationAdjustable mounting rails front and backColour: Fully epoxy powder coated
Features
•••••••
Main frameFront door - Perforated with cam lock2pcs Side panelsPanel mount support - 2pcs for 6U/9U, 4pcs for 12U/15U1pc 3 Gang trailing socket1 Pack of M6 caged nuts & screws (20pcs)Earthing screw
Standard Order Comprises of:
Front tempered glass door or fully perforated door
ModelCapacity
(U)Height(mm)
Weight(mm)
Depth(mm)
Packing Dimension(H*W*D)
Volume(CBM)
PG0950WM 9 467 500 0.1601486 x 610 x 540600
PG1250WM 12 595 500 0.2039619 x 610 x 540600
PG1550WM 15 730 500 0.2480753 x 610 x 540600
* P = Perforated door, G = Perspex with frame
* Customized sizes available upon request
EQUIPMENT RACKS
60
P-WM SeriesWall Mount Distribution Frame
•••••
•
•
Variety of heightsReliable welded main frameVented top and bottomComply with 19” wall mount standardFront lockable door with either Perspex withframe or PerforatedSuitable for stand alone or provided forstanding installationAdjustable mounting rails front and backColour: Fully epoxy powder coated
Features
•••••••
Main frameFront door - Perforated with cam lock2pcs Side panelsPanel mount support - 2pcs for 6U/9U, 4pcs for 12U/15U1pc 3 Gang trailing socket1 Pack of M6 caged nuts & screws (20pcs)Earthing screw
Standard Order Comprises of: Front tempered glass door or fully perforated door
Available Models
ModelCapacity
(U)Height(mm)
Weight(mm)
Depth(mm)
Packing Dimension(H*W*D)
Volume(CBM)
P0440WM 4 227 400 0.0648255 x 615 x 415600
PG0650WM 6 335 500 0.1163353 x 610 x 540600
* P = Perforated door, G = Perspex with frame
* Customized sizes available upon request
61
EQUIPMENT RACKS
PG-FS SeriesFloor Stand Distribution Frame
Available Models
••••
•••
Simple and sturdy designFront tempered glass door with ventilationFully perforated rear door for maximising ventilationEasy to dismantle front / real / side doors to enableconvenient operationComprehensive range of sizes availableColour - Fully epoxt powder coatedCan be supplied CKD
Features
••
•••
•
••
Power distribution unit: Horizontal 19” rack moutable in 1U heightShelves: Heavy duty shelves for equipment up to 60kg Cantilever shelf - avaialble in 2U Sliding shelf Vented shelfCooling fanLeveling feetCable management panel: 19” panel in 1U height to provideeffective cable managementBlank / Vented panel: Panels to cover unused space at the front ofthe cabinet. Available in variant sizesChassis runnerCage net assembly
Standard Order Comprises of:
ModelCapacity
(U)Height(mm)
Weight(mm)
Depth(mm)
Packing Dimension(H*W*D)
Volume(CBM)
PG1580FS 15 800 800600
PG1880FS 18 930 800600
PG2480FS 24 1200 800600
PG2880FS 28 1370 800600
PG3380FS 33 1600 800600
PG3780FS 37 1780 800600
PG4280FS 42 2000 800600
PG42100FS 42 2000 1000600
* P = Perforated door, G = Perspex with frame
* Customized sizes available upon request
Tempered galss door or fully perforated door
835 x 612 x 812
970 x 612 x 812
1235 x 612 x 812
1415 x 612 x 812
1635 x 612 x 812
1815 x 612 x 812
2035 x 612 x 812
2035 x 612 x 1012
0.4149
0.4820
0.6137
0.7032
0.8125
0.9020
1.0113
1.2604
EQUIPMENT RACKS
62
PG-TR SeriesTrunking Rack Distribution Frame
Available Models
ModelCapacity
(U)Height(mm)
Weight(mm)
Depth(mm)
Packing Dimension(H*W*D)
Volume(CBM)
PG4280TR 15 800 800 1.34182035 x 612 x 800600
PG42100FS 18 930 800 1.67222035 x 612 x 1012600
* P = Perforated door, G = Perspex with frame
* Customized sizes available upon request
••••
•••
Simple and sturdy designFront tempered glass door with ventilationFully perforated rear door for maximising ventilationEasy to dismantle front / real / side doors to enableconvenient operationComprehensive range of sizes availableColour - Fully epoxt powder coatedCan be supplied CKD
Features
••
•••
•
••
Power distribution unit: Horizontal 19” rack moutable in 1U heightShelves: Heavy duty shelves for equipment up to 60kg Cantilever shelf - avaialble in 2U Sliding shelf Vented shelfCooling fanLeveling feetCable management panel: 19” panel in 1U height to provideeffective cable managementBlank / Vented panel: Panels to cover unused space at the front ofthe cabinet. Available in variant sizesChassis runnerCage net assembly
Standard Order Comprises of:
Tempered galss door or fully perforated door
63
EQUIPMENT RACKS
MULTIMEDIA SPECIALS &STRUCTURED CABLING SOLUTIONS
DISTRIBUTED BY
Product design and specifications are subject to change with notice.All pictures in this content are for illustration purpose only, actual product may vary.