90
© 2011 Honda Motor Co., Ltd.—All Rights Reserved Owner’s Manual GENERATOR EB4000X • EB5000X • EB6500X See page 80 for Initial Use Instructions

Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

00X31-Z23-800031Z23800 AHM.35.2011.02

PRINTED IN U.S.A.Printed on

Recycled Paper © 2011 Honda Motor Co., Ltd.—All Rights Reserved

Owner’s ManualGENERATOR

EB4000X • EB5000X • EB6500X

See page 80 forInitial Use Instructions

C

M

Y

CM

MY

CY

CMY

K

EB4000-6500X Cover.ai 2/8/2011 11:10:02 AMEB4000-6500X Cover.ai 2/8/2011 11:10:02 AM

Page 2: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

Exhaust contains poisonous carbonmonoxide gas that can build up todangerous levels in closed areas.Breathing carbon monoxide cancause unconsciousness or death.

Never run the generator in a closed,or even partly closed area wherepeople may be present.

The information and specifications included in this publication were ineffect at the time of approval for printing. Honda Motor Co., Ltd.reserves the right, however, to discontinue or change specifications ordesign at any time without notice and without incurring any obligationwhatever.

Keep this owner’s manual handy so that you can refer to it at any time.This owner’s manual is considered a permanent part of the generatorand should remain with the generator if resold.

The engine exhaust from this productcontains chemicals known to the State

of California to cause cancer, birthdefects or other reproductive harm.

10/10/12 14:30:47 31Z23800_001

Page 3: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

1

INTRODUCTION

Congratulations on your selection of a Honda generator. We arecertain you will be pleased with your purchase of one of the finestgenerators on the market.

We want to help you get the best results from your new generator andto operate it safely. This manual contains all the information on how todo that; please read it carefully.

As you read this manual, you will find information preceded by asymbol. That information is intended to help you avoid

damage to your generator, other property, or the environment.

We suggest you read the Distributor’s Limited Warranty to fullyunderstand its coverage and your responsibilities of ownership. TheDistributor’s Limited Warranty is a separate document that shouldhave been given to you by your dealer.

When your generator needs scheduled maintenance, keep in mindthat your Honda servicing dealer is specially trained in servicingHonda generators and is supported by the parts and service divisionsof American Honda. Your Honda servicing dealer is dedicated to yoursatisfaction and will be pleased to answer your questions andconcerns.

Best Wishes,Honda Motor Co., Ltd.

10/10/12 14:30:53 31Z23800_002

Page 4: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

2

A FEW WORDS ABOUT SAFETY

Safety Labels

Safety Messages

Safety Headings

Safety Section

Instructions

Your safety and the safety of others are very important. And using thisgenerator safely is an important responsibility.

To help you make informed decisions about safety, we have providedoperating procedures and other information on labels and in thismanual. This information alerts you to potential hazards that couldhurt you or others.

Of course, it is not practical or possible to warn you about all thehazards associated with operating or maintaining a generator. Youmust use your own good judgement.

You will find important safety information in a variety of forms,including:

on the generator.

preceded by a safety alert symbol and oneof three signal words, DANGER, WARNING, or CAUTION.

These signal words mean:

be or ifyou don’t follow instructions.

be or ifyou don’t follow instructions.

be if you don’t followinstructions.

such as IMPORTANT SAFETY INFORMATION.

such as

how to use this generator correctly and safely.

This entire book is filled with important safety information pleaseread it carefully.

You WILL KILLED SERIOUSLY HURT

You CAN KILLED SERIOUSLY HURT

You CAN HURT

GENERATOR SAFETY .

10/10/12 14:31:03 31Z23800_003

Page 5: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

3

CONTENTS

................................................................................GENERATOR SAFETY .6

........................................................................CONTROLS & FEATURES .10

...............................................................................BEFORE OPERATION .24

..................................................IMPORTANT SAFETY INFORMATION .6......................................................................Operator Responsibility .6

.................................................................Carbon Monoxide Hazards .6.......................................................................Electric Shock Hazards .7........................................................................Fire and Burn Hazards .7

.................................................................................Refuel With Care .8.................................................................SAFETY LABEL LOCATIONS .9

...........................................COMPONENT & CONTROL LOCATIONS .10............................................................................................CONTROLS .12

....................................................................................Engine Switch .12........................................................................................Starter Grip .12

................................................................................Fuel Valve Lever .13...................................................................Voltage Selector Switch .13

......................................................................Auto Throttle System .14.........................................................................AC Circuit Protectors .14

.............................................................................AC Circuit Breaker .15..................................................................................Folding Handle .16

.............................................................................................FEATURES .17..............................................................................Oil Alert System .17

.....................................................Automatic Engine Stop Function .17..............................................................................Oil Alert Function .17

........................................................Overspeed Detection Function .17............................................Abnormal Voltage Detection Function .17

.......................................Auto Choke and Throttle Control System .18......................................iAVR (Intelligent Auto Voltage Regulator) .18

.........................................................................................Fuel Gauge .19...............................................................................Ground Terminal .19

...........................................Ground Fault Circuit Interrupter (GFCI) .20

................................................ARE YOU READY TO GET STARTED? .24.........................................................................................Knowledge .24

..............................................IS YOUR GENERATOR READY TO GO? .24...............................................................................Check the Engine .25

10/10/12 14:31:06 31Z23800_004

Page 6: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

4

CONTENTS

..............................................................................................OPERATION .26

.............................................................SERVICING YOUR GENERATOR .39

..................................................................................................STORAGE .54

.....................................................SAFE OPERATING PRECAUTIONS .26......................................................................STARTING THE ENGINE .27......................................................................STOPPING THE ENGINE .30

.....................................................................................AC OPERATION .31.................................................................................AC Applications .32

...................................................................AC Receptacle Selection .33.................................................................Power Producing Circuits .33

...................................................................Voltage Selector Switch .34................................................................AUTO THROTTLE SYSTEM .36

................................................................................STANDBY POWER .37...............................Connections to a Building’s Electrical System .37

.................................................................................System Ground .37.......................................................................Special Requirements .38

.............................................THE IMPORTANCE OF MAINTENANCE .39......................................................................MAINTENANCE SAFETY .40

............................................................................Safety Precautions .40................................................................MAINTENANCE SCHEDULE .41

...........................................................................................REFUELING .42...............................................................FUEL RECOMMENDATIONS .43

..................................................................ENGINE OIL LEVEL CHECK .44...........................................................................ENGINE OIL CHANGE .45

....................................................ENGINE OIL RECOMMENDATIONS .46........................................................................AIR CLEANER SERVICE .47

..................................................AIR CLEANER ELEMENT CLEANING .49.........................................................................SPARK PLUG SERVICE .50

................................................................SPARK ARRESTER SERVICE .52.................................................................SEDIMENT CUP CLEANING .53

....................................................................STORAGE PREPARATION .54.............................................................................................Cleaning .54

.....................................................................................................Fuel .54..........................................................................................Engine Oil .57

...................................................................STORAGE PRECAUTIONS .58................................................................REMOVAL FROM STORAGE .58

10/10/12 14:31:10 31Z23800_005

Page 7: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

5

CONTENTS

......................................................................................TRANSPORTING .59

.......................................TAKING CARE OF UNEXPECTED PROBLEMS .60

....................................................................TECHNICAL INFORMATION .64

...................................................................CONSUMER INFORMATION .72

...............................................................................................ASSEMBLY .74

..................................................................INITIAL USE INSTRUCTIONS .80

........................................................................................................INDEX .83

.............................QUICK REFERENCE INFORMATION .Inside back cover

...................................................................ENGINE WILL NOT START .60.......................................................................ENGINE LACKS POWER .61

..............................................NO POWER AT THE AC RECEPTACLES .62....................................NO ELECTRICITY AT THE AC RECEPTACLES .63

.......................................................................Serial Number Location .64.......................Carburetor Modification for High Altitude Operation .65

...............................................Emission Control System Information .66................................................................................................Air Index .68

........................................................................................Specifications .69.....................................................................................Wiring Diagram .70

..................................................................Dealer Locator Information .72..............................................................................Honda Publications .72

............................................................Customer Service Information .73

..................................................................................................SAFETY .74..............................................The Importance of Proper Assembly .74

..........................................................Important Safety Precautions .75............................................................................................ASSEMBLY .76..........................................................................................Unpacking .76........................................................................................Loose Parts .76

........................................................................Wheel Kit Installation .77............................................................................Handle Installation .78

......................................................................Hanger Kit Installation .79

...........................................................................................ENGINE OIL .80.......................................................................................................FUEL .81

...........................................................................BEFORE OPERATION .82.....................................................................................REGISTRATION .82

10/10/12 14:31:13 31Z23800_006

Page 8: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

6

GENERATOR SAFETY

Operator Responsibility

Carbon Monoxide Hazards

IMPORTANT SAFETY INFORMATION

Honda generators are designed for use with electrical equipment thathas suitable power requirements. Other uses can result in injury to theoperator or damage to the generator and other property.Most injuries or property damage can be prevented if you follow allinstructions in this manual and on the generator. The most commonhazards are discussed below, along with the best way to protectyourself and others.

Be sure that anyone who operates the generator receives properinstruction. Do not let children operate the generator withoutparental supervision.

Know how to stop the generator quickly in case of emergency.

Understand the use of all generator controls, output receptacles,and connections.

Exhaust contains poisonous carbon monoxide, a colorless, odorlessgas. Breathing carbon monoxide can cause loss of consciousnessand may lead to death.

If you run the generator in an area that is confined, or even partlyenclosed area, the air you breathe could contain a dangerousamount of exhaust gas.

Never run your generator inside a garage, house, or near openwindows or doors.

10/10/12 14:31:20 31Z23800_007

Page 9: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

--

7

GENERATOR SAFETY

Electric Shock Hazards

Fire and Burn Hazards

The generator produces enough electric power to cause a seriousshock or electrocution if misused.

Using a generator or electrical appliance in wet conditions, such asrain or snow, or near a pool or sprinkler system, or when your handsare wet, could result in electrocution. Keep the generator dry.

If the generator is stored outdoors, unprotected from the weather,check all of the electrical components on the control panel beforeeach use. Moisture or ice can cause a malfunction or short circuit inelectrical components that could result in electrocution.

Do not connect to a building’s electrical system unless an isolationswitch has been installed by a qualified electrician.

The exhaust system gets hot enough to ignite some materials.Keep the generator at least 3 feet (1 meter) away from buildingsand other equipment during operation.Do not enclose the generator in any structure.Keep flammable materials away from the generator.

The muffler becomes very hot during operation and remains hot fora while after stopping the engine. Be careful not to touch the mufflerwhile it is hot. Let the engine cool before storing the generatorindoors.

10/10/12 14:31:27 31Z23800_008

Page 10: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

8

GENERATOR SAFETY

Refuel With Care

Gasoline is extremely flammable, and gasoline vapor can explode.Allow the engine to cool if the generator has been in operation. Refuelonly outdoors in a well-ventilated area with the engine off. Do notoverfill the fuel tank. Never smoke near gasoline, and keep otherflames and sparks away. Always store gasoline in an approvedcontainer. Make sure that any spilled fuel has been wiped up beforestarting the engine.

10/10/12 14:31:30 31Z23800_009

Page 11: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

9

GENERATOR SAFETY

SAFETY LABEL LOCATIONS

If a label comes off or becomes hard to read, contact your Hondagenerator dealer for a replacement.

These labels warn you of potential hazards that can cause seriousinjury. Read them carefully.

10/10/12 14:31:44 31Z23800_010

Page 12: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

10

CONTROLS & FEATURES

COMPONENT & CONTROL LOCATIONS

GFCI TEST BUTTON

GFCI RESET BUTTON

AC CIRCUIT PROTECTORS

AUTO THROTTLESWITCH

AC CIRCUIT BREAKER

: Except EB4000X

ENGINE SWITCH

120 V/240 V ACRECEPTACLE

112200 VV AACC RREECCEEPPTTAACCLLEESS

VOLTAGE SELECTOR SWITCH

GROUND TERMINAL

Use the illustrations on these pages to locate and identify the mostfrequently used controls.

10/10/12 14:31:50 31Z23800_011

Page 13: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

11

CONTROLS & FEATURES

AIR CLEANER

FUEL VALVE LEVER

OIL DRAIN PLUG

STARTER GRIP

STAND

LIFTING HANGER

FUEL GAUGE

WHEEL MUFFLER

SPARK PLUG

OIL FILLER CAP/DIPSTICK

CONTROL PANEL

SEDIMENT CUP

FUEL TANK CAP

HANDLE

MANUAL CHOKE LEVER

10/10/12 14:31:55 31Z23800_012

Page 14: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

12

CONTROLS & FEATURES

CONTROLS

Starter Grip

Engine Switch

OONN

OOFFFF

ENGINE SWITCH

DDiirreeccttiioonn ttoo ppuullll

STARTER GRIP

Pulling the starter grip operatesthe recoil starter to crank theengine.

The engine switch controls theignition system.

OFF Stops the engine.

ON Running position, and forstarting.

Do not allow the starter grip tosnap back against the generator.Return it gently to preventdamage to the starter.Do not let the starter rope rubagainst the generator body, orthe rope will wear outprematurely.Be careful not to hit your handagainst the handle when pullingthe starter grip.

10/10/12 14:32:04 31Z23800_013

Page 15: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

13

CONTROLS & FEATURES

Fuel Valve Lever

Voltage Selector Switch

Switch Position

120V/240V:

120V ONLY:

OONN

OOFFFF

FUEL VALVE LEVER

VOLTAGE SELECTOR SWITCH

120 V/240 V

120 V ONLY

The fuel valve lever is locatedbetween the fuel tank andcarburetor.

The fuel valve must be in the ONposition for the engine to run.

After stopping the engine, turnthe fuel valve to the OFF position.

The voltage selector switch switches generator output to produce‘‘120V ONLY’’ or ‘‘120V/240V.’’ If a 240V appliance is connected to the4-prong receptacle, the switch must be in the ‘‘120V/240V’’ position. Ifonly a 120V appliance is being connected to any of the 120V 3-prongreceptacles, select the ‘‘120V ONLY’’ position.Select the voltage before starting the engine.

The 120V and 120V/240V receptacles can be usedsimultaneously.

ONLY 120 volts is available in this position; 240 volts isnot available. The most power will be available at the 30A 120V lockingplug receptacle.

10/10/12 14:32:13 31Z23800_014

Page 16: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

14

CONTROLS & FEATURES

Auto Throttle System

Switch Position

AC Circuit Protectors

AUTO:

OFF:

OOFFFF

OONN

AUTO THROTTLE SWITCH

OONNOOFFFF

AC CIRCUIT PROTECTORfor Receptacle

120 V/240 V 30 A (EB5000X,EB6500X)

120 V/240 V 20 A (EB4000X)

120 V 30 A

ON

OFF

AC CIRCUIT PROTECTORfor Receptacle

AC CIRCUIT PROTECTORfor Receptacle

AC CIRCUIT PROTECTORfor Receptacle

PUSH

:Except EB4000X

112200 VV 2200 AA

112200 VV 2200 AA

The Auto Throttle system automatically reduces engine speed whenall loads are turned off or disconnected. When appliances are turnedon or reconnected, the engine returns to the rated speed.

The Auto Throttle system does not operate.Recommended to minimize warm-up time when thegenerator is started and when starting a load with large start-up power equipments.

Recommended to minimize fuel consumption and furtherreduce noise levels when no load is applied to the generator.

The AC circuit protectors will automatically switch OFF if there is ashort circuit or a significant overload of the generator at eachreceptacle. If an AC circuit protector switches OFF automatically, checkthat the appliance is working properly and does not exceed the ratedload capacity of the circuit before resetting the AC circuit protector ON.

10/10/12 15:37:07 31Z23800_015

Page 17: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

15

CONTROLS & FEATURES

AC Circuit Breaker

GFCI RESET BUTTON

ON

OFFAC CIRCUIT BREAKER

The AC circuit breaker will automatically switch OFF if there is a shortcircuit or a significant overload at the receptacles, or if the ground faultcircuit interrupter (GFCI) detects a ground fault current.

Check the following if the AC circuit breaker switches OFFautomatically:

When the GFCI RESET button is extended (page ):

Check that the appliance is working properly and does not exceedthe rated load capacity of the circuit before switching the ACcircuit breaker ON again.

When the GFCI RESET button is not extended:

The AC circuit breaker may be used to switch the generator power ONor OFF.

Unplug all appliances from the receptacles and check theappliance for any defects as described in TAKING CARE OFUNEXPECTED PROBLEMS (page ).

After making repairs, push the GFCI RESET button, and then turnthe AC circuit breaker ON.

22

60

10/10/12 14:32:30 31Z23800_016

Page 18: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

16

CONTROL & FEATURES

Folding Handle

To Extend The Handle

To Fold The Handle

HANDLE

HANDLE LOCK LEVERGeneratorstationaryposition

Handletransportposition

The foldable handle is intended for ease of transportation and shouldbe folded when the generator is stationary. Do not rest objects on theextended handle.

Lower the handle.

Lift handle upward. Lock lever will lock and secure the handle intoplace.

Press handle lock lever downward.2.1.

10/10/12 14:32:38 31Z23800_017

Page 19: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

17

CONTROLS & FEATURES

FEATURES

Oil Alert System

Automatic Engine Stop Function

Oil Alert Function

Overspeed Detection Function

Abnormal Voltage Detection Function

The Oil Alert system is designed to prevent engine damage caused byan insufficient amount of oil in the crankcase. Before the oil level in thecrankcase can fall below a safe limit, the Oil Alert system willautomatically stop the engine (the engine switch will remain in the ONposition).

If the engine stops and will not restart, check the engine oil level (seepage ) before troubleshooting in other areas.

During operation, the engine will automatically stop if there is notenough oil in the tank. Moreover, if the generator is on a slope, the oilalert function may operate and stop the engine.

To protect the engine from exceeding the engine load, the engine willautomatically stop if the engine speed becomes abnormal.

The engine will automatically stop during generation when it detectsabnormal voltage.

If the engine stops, make sure the oil level is correct. Wait a fewminutes, and then try to restart the engine. If the engine still won’tstart, take the generator to your authorized servicing Honda powerequipment dealer.

44

10/10/12 14:32:46 31Z23800_018

Page 20: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

18

CONTROLS & FEATURES

Auto Choke and Throttle Control System

iAVR (Intelligent Auto Voltage Regulator)

ECM

MANUAL CHOKE LEVER

ECM: Engine Control Module

The ECM of this engine controls the choke valve and throttleautomatically.

When starting and warming up the engine, you do not need to operatethe choke lever unless the engine is hard to start using the normalstarting procedure.

This generator is equipped with an intelligent, automatic voltageregulator. The iAVR provides power in excess of the maximum ratingfor up to ten seconds to start appliances that require high startupcurrent.

The total amount of power available for each generator model is:5,000 watts for up to 10 seconds7,000 watts for up to 10 seconds7,000 watts for up to 10 seconds

EB4000XEB5000XEB6500X

10/10/12 14:32:54 31Z23800_019

Page 21: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

19

CONTROLS & FEATURES

Fuel Gauge

Ground Terminal

GROUND TERMINAL

FUEL GAUGE FUEL TANK CAP

EMPTYFULL

The fuel gauge is a mechanical device that measures the fuel level inthe tank. The red indicator in the window will reference the level inrelation to full or empty. To provide increased operating time, startwith a full tank before beginning operation. Check the fuel level withthe generator on a level surface. Always refuel with the engine OFFand cool.

Before using the ground terminal, consult a qualified electrician,electrical inspector, or local agency having jurisdiction for local codesor ordinances that apply to the intended use of the generator.

The generator ground terminal is connected to the frame of thegenerator, the metal non-current-carrying parts of the generator, andthe ground terminals of each receptacle.

10/10/12 14:33:01 31Z23800_020

Page 22: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

20

CONTROLS & FEATURES

Ground Fault Circuit Interrupter (GFCI)

AC CIRCUIT BREAKERGFCI RESET BUTTON

GFCI TEST BUTTON

All receptacles on the generator are protected by a Ground FaultCircuit Interrupter (GFCI) for protection against the shock hazard ofground fault current. The GFCI has a TEST and RESET button and isconnected to the AC circuit breaker.

An example of ground-fault current is the current that would flowthrough a person who is using an appliance with faulty insulation and,at the same time, is in contact with an electrical ground such as aplumbing fixture, wet floor, or earth.

The ground fault circuit interrupter will not protect against shortcircuits or overloads. The AC circuit breaker in the control panel thatsupplies power to the circuit provides that protection (refer to ACcircuit breaker on page ).

Using the generator in rain or snowor near water can lead to death fromelectric shock. Keep the generatordry.

15

10/10/12 14:33:07 31Z23800_021

Page 23: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

21

CONTROLS & FEATURES

Observe the following precautions to ensure proper GFCI operationand to reduce shock hazards:

Use grounded 3-conductor extension cords, tools, and appliances,or double-insulated tools and appliances.

Inspect cords and plugs, and replace if damaged.

Do not use cord lengths greater than 164 feet (50 meters), and donot use multiple tools and appliances with built-in noise filters. Suchuse may activate the GFCI and trip the AC circuit breaker.

10/10/12 14:33:11 31Z23800_022

Page 24: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

22

CONTROLS & FEATURES

Inspection:

GFCI RESET BUTTON

GFCI TEST BUTTON

OFFAC CIRCUIT BREAKER

Always check GFCI operation before using the generator.

Unplug all tools and appliances from the generator.

Start the engine.

Turn the AC circuit breaker to the ON position.

Press the GFCI TEST button. The RESET button should extend, andthe AC circuit breaker should switch to the OFF position.

If the GFCI and AC circuit breaker do not function as described, takethe generator to an authorized Honda generator dealer for repair.

You risk electric shock if youoperate this generator with a faultyGFCI (ground fault circuitinterrupter).

Test GFCI before use.

If GFCI fails test, do not use yourgenerator. See your Honda dealer.

Turn the Auto Throttle switch to the OFF position.

1.

2.

3.

4.

5.

10/10/12 14:33:19 31Z23800_023

Page 25: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

23

CONTROLS & FEATURES

GFCI RESET BUTTON

ON

AC CIRCUIT BREAKER

Press the GFCI RESET button. The RESET button should stay in,flush with its base plate.

With the RESET button in and the engine running, turn the AC circuitbreaker to the ON position. The AC circuit breaker should remain inthe ON position. The AC circuit breaker will not remain in the ONposition if the RESET button is extended.

If the GFCI and AC circuit breaker do not function as described, takethe generator to an authorized Honda generator dealer for repair.

During generator use, if the GFCI RESET button extends and the ACcircuit breaker trips, this usually indicates a faulty power tool,appliance, or cord.

If that occurs, perform test steps 1 through 6 to verify that the GFCIand AC circuit breaker are in proper working order. If the GFCI and ACcircuit breaker test correctly, then you will know that the fault is in thepower tool, appliance, or cord. Repair or replace the faulty power tool,appliance, or cord before further use.

6.

10/10/12 14:33:25 31Z23800_024

Page 26: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

24

BEFORE OPERATION

ARE YOU READY TO GET STARTED?

Knowledge

IS YOUR GENERATOR READY TO GO?

Your safety is your responsibility. A little time spent in preparation willsignificantly reduce your risk of injury.

Read and understand this manual. Know what the controls do andhow to operate them.

Familiarize yourself with the generator and its operation before youbegin using it. Know how to quickly shut off the generator in case ofan emergency.

For your safety, and to maximize the service life of your equipment, itis very important to take a few moments before you operate thegenerator to check its condition. Be sure to take care of any problemyou find, or have your servicing dealer correct it, before you operatethe generator.

Improperly maintaining thisgenerator, or failing to correct aproblem before operation, couldcause a malfunction in which youcould be seriously injured.

Always perform a pre-operationinspection before each operation,and correct any problem.

If the generator is being used to power appliances, be sure that theydo not exceed the generator’s load rating (see page ).32

10/10/12 14:33:32 31Z23800_025

Page 27: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

25

BEFORE OPERATION

Check the Engine

To prevent a possible fire, keep the generator at least 3 feet (1 meter)away from building walls and other equipment during operation. Donot place flammable objects close to the engine.

Before beginning your pre-operation checks, be sure the generator ison a level surface and the engine switch is in the OFF position.

Check the oil level (see page ). A low oil level will cause the Oil Alertsystem to shut down the engine or prevent it from starting.

Check the air cleaner (see page ). A dirty air cleaner element willrestrict air flow to the carburetor, reducing engine and generatorperformance.

Check the fuel level (see page ). Starting with a full tank will help toeliminate or reduce operating interruptions for refueling.

44

47

42

10/10/12 14:33:38 31Z23800_026

Page 28: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

26

SAFE OPERATING PRECAUTIONS

OPERATION

For your safety, do not operate the generator in an enclosed area suchas a garage. Your generator’s exhaust contains poisonous carbonmonoxide gas that can collect rapidly in an enclosed area and causeillness or death.

Exhaust contains poisonous carbonmonoxide gas that can build up todangerous levels in closed areas.Breathing carbon monoxide cancause unconsciousness or death.

Never run the generator in a closed,or even partly closed area wherepeople may be present.

Use grounded 3-prong extension cords, tools, and appliances, ordouble-insulated tools and appliances.

Before connecting an AC appliance or power cord to the generator:

Inspect cords and plugs, and replace if damaged.Make sure that the appliance is in good working order. Faultyappliances or power cords can create a potential for electric shock.Make sure the electrical rating of the tool or appliance does notexceed that of the generator. Never exceed the maximum powerrating of the generator. Power levels between rated and maximummay be used for no more than 30 minutes.Operate the generator at least 3 feet (1 meter) away from buildingsand other equipment.Do not operate the generator in an enclosed structure.

Before operating the generator for the first time, review chaptersGENERATOR SAFETY (see page ) and BEFORE OPERATION (seepage ).

624

10/10/12 14:33:47 31Z23800_027

Page 29: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

27

OPERATION

STARTING THE ENGINE

FUEL VALVE LEVER

OONN

OOFFFF

AC CIRCUIT BREAKER

To prevent a possible fire, keep the generator at least 3 feet (1 meter)away from building walls and other equipment during operation. Donot place flammable objects close to the engine.

Operating this generator less than 3 feet (1 meter) from a building orother obstruction can cause overheating and damage the generator.For proper cooling, allow at least 3 feet (1 meter) of empty spaceabove and around the generator.

Refer to SAFE OPERATING PRECAUTIONS on page and perform theIS YOUR GENERATOR READY TO GO checks (see page ). Refer toAC OPERATION (see page ) for connecting loads to the generator.

Turn the fuel valve lever to theON position.

Make sure that the AC circuitbreaker is in the OFF position.The generator may be hard tostart if a load is connected.

1.

2.

2431

26

10/10/12 14:33:55 31Z23800_028

Page 30: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

28

OPERATION

ENGINE SWITCH

OFF

OONN

DDiirreeccttiioonn ttoo ppuullll

STARTER GRIP

AUTO THROTTLE SWITCHMake sure the Auto Throttleswitch is in the OFF position, ormore time will be required forwarm up.

Pull the starter grip lightly untilyou feel resistance; then pullbriskly in the direction of thearrow as shown.

Do not allow the starter gripto snap back against theengine. Return it gently toprevent damage to the starter.Do not let the starter rope rubagainst the generator body,or the rope will wear outprematurely.

Turn the engine switch to theON position.

Be careful not to hit yourhand against the handlewhen pulling the starter grip.

5.

4.

3.

10/10/12 14:34:03 31Z23800_029

Page 31: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

29

OPERATION

OONN

AUTO THROTTLE SWITCHIf you wish to use the AutoThrottle system, turn the AutoThrottle switch to the ONposition after the engine haswarmed up for 2 or 3 minutes.

6.

10/10/12 14:34:07 31Z23800_030

Page 32: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

30

OPERATION

STOPPING THE ENGINE

OOFFFF

ENGINE SWITCH

AC CIRCUIT BREAKER

OOFFFF

FUEL VALVE LEVER

OOFFFF

To stop the engine in an emergency, simply turn the engine switch tothe OFF position. Under normal conditions, use the followingprocedure.

Turn off or disconnect all appliances that are connected to thegenerator.

Move the AC circuit breaker tothe OFF position.

Turn the fuel valve lever to theOFF position.

Turn the engine switch to theOFF position.

1.

2.

3.

4.

10/10/12 14:34:14 31Z23800_031

Page 33: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

31

OPERATION

AC OPERATION

VOLTAGE SELECTOR SWITCH

PLUG

AC CIRCUIT PROTECTORS

120 V/240 V

120 V ONLY

: Except EB4000X

OONN

AC CIRCUITBREAKER

If an appliance begins to operate abnormally, becomes sluggish, orstops suddenly, turn it off immediately. Disconnect the appliance, anddetermine whether the problem is in the appliance or the rated loadcapacity of the generator has been exceeded.

Substantial overloading may damage the generator. Marginaloverloading may shorten the service life of the generator.

Turn the voltage selector switchto either position.With the voltage selector switchin the ‘‘120V/240V’’ position,you can use the 120V and 120V/240V receptaclessimultaneously. If you are NOTusing 240 volts, then select the‘‘120V ONLY’’ position.

Start the engine (see page ).

Switch ON the AC circuit breaker.

Plug in the appliance.Most motorized appliancesrequire more than their ratedwattage for startup.

If the generator is overloaded and the internal circuit is overheated,current to the connected appliance(s) may shut off, even though theAC circuit breaker stays ON and the engine keeps running.Stop the engine and correct the problem. Allow the generator to coolfor a few minutes, and then restart the engine (see page ).

Do not exceed the current limit specified for any one receptacle. If anoverloaded circuit causes the AC circuit breaker or AC circuit protectorto switch OFF, reduce the electrical load on the circuit, wait a fewminutes and then reset the AC circuit breaker or AC circuit protector.

Turn on the appliance.

1.

2.

3.

4.

5.

27

27

10/11/04 12:45:47 31Z23800_032

Page 34: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

32

OPERATION

AC Applications

Before connecting an appliance or power cord to the generator:

If an appliance begins to operate abnormally, becomes sluggish, orstops suddenly, turn it off immediately. Disconnect the appliance,and determine whether the problem is the appliance or the ratedload capacity of the generator has been exceeded.

Limit operation requiring maximum power to 30 minutes.Maximum power is:

Make sure that it is in good working order. A faulty appliance orpower cord can create a potential for electrical shock.

Make sure that the combined electrical rating of the tools orappliances do not exceed that of the generator. Never exceed themaximum power rating of the generator. Power levels betweenrated and maximum may be used for no more than 30 minutes.

4.0 kVA5.0 kVA6.5 kVA

For continuous operation (longer than 30 minutes), do not exceed therated power.Rated power is:

3.6 kVA4.5 kVA5.5 kVA

The total power requirements (VA) of all appliances connected mustbe considered. Appliance and power tool manufacturers usually listrating information near the model number or serial number.

Substantial overloading will open the AC circuit breaker. Exceedingthe time limit for maximum power operation or slightly overloadingthe generator may not switch the AC circuit breaker OFF, but willshorten the service life of the generator.

EB4000X:EB5000X:EB6500X:

EB4000X:EB5000X:EB6500X:

10/10/12 14:34:34 31Z23800_033

Page 35: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

○○

33

OPERATION

AC Receptacle Selection

Power Producing Circuits

4A

4B

4A 4B

: Except EB4000X

120 V/240 V 120 V ONLY

120 V 30 A120 V 20 A120 V 20 A& 120 V/240 V 20 A (EB4000X)

120 V/240 V 30 A (EB5000X, EB6500X)

POWERCIRCUIT B

POWERCIRCUIT A

POWER CIRCUIT A

POWER CIRCUIT B

The control panel, shown below, has a voltage selector switch andfour receptacles. Receptacle 4, the 240-volt receptacle, has twopowered terminals, 4A and 4B.

When the voltage selector switch is in the 120V ONLY position, thepower producing circuits operate in parallel, sharing the total loadconnected to terminal 4A and receptacles 1, 2, and 3.

This generator is equipped with two power generating circuits.When the voltage selector switch is in the 120V/240V position, eachof the two power producing circuits supplies power to specificreceptacles.

10/10/12 14:34:42 31Z23800_034

Page 36: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

34

OPERATION

Voltage Selector Switch

120V ONLY Position

Available PowerSwitchPosition EB4000X EB5000X EB6500X

Receptacle

The power available to each receptacle depends on the position of thevoltage selector switch.

120V ONLY

120V/240V

1

2

3

4A

4B

1

2

3

4A-4B

45.8 A37.5 A30.0 ATotal Current Available:

30A at 120V

20A at 120V

20A at 120V

20A at 120V

None

15.0A at 120V

15.0A at 120V

15.0A at 120V

15.0A at 240V

30A at 120V

20A at 120V

20A at 120V

30A at 120V

None

18.8A at 120V

18.8A at 120V

18.8A at 120V

18.8A at 240V

30A at 120V

20A at 120V

20A at 120V

30A at 120V

None

22.9A at 120V

20A at 120V

20A at 120V

22.9A at 240V

When the voltage selector switch is in the 120V ONLY position, you donot need to spread the load over the receptacles. You must, however,make sure the load on any receptacle does not exceed its availablepower shown in the table above and the total load does not exceed thetotal current available.

(EB4000X)(EB5000X)(EB6500X)

10/10/12 14:34:51 31Z23800_035

Page 37: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

+ +

35

OPERATION

120V/240V Position

Set ofReceptacles EB4000X EB5000X EB6500X

Total Current Available Power ProducingCircuit

When the voltage selector switch is in the 120V/240V position, youmust balance the load. Divide the load between the two sets ofreceptacles shown below. Balancing is necessary because each set ofreceptacles is powered by only one power producing circuit that canproduce a maximum of amps( ).

15.0 A18.8 A22.9 A

15.0A

15.0A

18.8A

18.8A

22.9A

22.9A

:

1 3 4B

2 4A

(EB4000X)(EB5000X)(EB6500X)

B

A

10/10/12 14:34:59 31Z23800_036

Page 38: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

36

OPERATION

AUTO THROTTLE SYSTEM

OFF

ON

OFF

ON

AUTO THROTTLE SWITCH

The Auto Throttle system is not effective for use with appliances thatrequire only momentary power. If the tool or appliance will be turnedON and OFF quickly, the Auto Throttle switch should be in the OFFposition.

To avoid extended warm-up periods, keep the switch OFF until theengine reaches operating temperature.

Appliances with large start-up power demands may not allow theengine to reach normal operating rpm when they are connected to thegenerator. Push the Auto Throttle switch to the OFF position andconnect the appliance to the generator. If the engine still will not reachnormal operating speed, check that the appliance does not exceed therated load capacity of the generator.

The Auto Throttle system will not respond to electrical loads of lessthan 1 ampere or intermittent loads such as a staple gun. Turn theAuto Throttle switch to the OFF position to operate loads of less than 1amp.

With the switch in the AUTO position, engine speed is automaticallyreduced when ALL loads are turned OFF or disconnected. Whenappliances are turned ON or reconnected, the engine returns to ratedspeed. In the OFF position, the Auto Throttle system does not operate.

10/10/12 14:35:05 31Z23800_037

Page 39: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

37

OPERATION

STANDBY POWER

Connections to a Building’s Electrical System

System Ground

Connections for standby power to a building’s electrical system mustbe made by a qualified electrician. The connection must isolate thegenerator power from utility power, and must comply with allapplicable laws and electrical codes.

Improper connections to a building’selectrical system can allow currentfrom the generator to backfeed intothe utility lines.

Such backfeed may electrocuteutility company workers or otherswho contact the lines during apower outage, and the generatormay explode, burn, or cause fireswhen utility power is restored.

Consult the utility company or aqualified electrician prior to makingany power connections.

In some areas, generators are required by law to be registered withlocal utility companies. Check local regulations for proper registrationand use procedures.

Honda portable generators have a system ground that connects thegenerator frame components to the ground terminals in the AC outputreceptacles. The system ground is connected to the AC neutral wire. Ifthe generator is tested with a receptacle tester, it will show the sameground circuit condition as for a home receptacle.

10/10/12 14:35:11 31Z23800_038

Page 40: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

38

OPERATION

Special Requirements

There may be Federal or State Occupational Safety and HealthAdministration (OSHA) regulations, local codes, or ordinances thatapply to the intended use of the generator. Please consult a qualifiedelectrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with localutility companies.

If the generator is used at a construction site, there may beadditional regulations that must be observed.

10/10/12 14:35:16 31Z23800_039

Page 41: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

39

SERVICING YOUR GENERATOR

THE IMPORTANCE OF MAINTENANCE

Maintenance, replacement, or repair of the emission control devicesand systems may be performed by any engine repair establishment orindividual, using parts that are ‘‘certified’’ to EPA standards.

Good maintenance is essential for safe, economical, and trouble freeoperation. It will also help reduce air pollution.

To help you properly care for your generator, the following pagesinclude a maintenance schedule, routine inspection procedures, andsimple maintenance procedures using basic hand tools. Other servicetasks that are more difficult or require special tools are best handledby professionals and are normally performed by a Honda technician orother qualified mechanic.

The maintenance schedule applies to normal operating conditions. Ifyou operate your generator under unusual conditions, such assustained high-load or high-temperature operation, or use it in dustyconditions, consult your servicing dealer for recommendationsapplicable to your individual needs and use.

Improper maintenance, or failure tocorrect a problem before operation,can cause a malfunction in whichyou can be seriously hurt or killed.

Always follow the inspection andmaintenance recommendations andschedules in this owner’s manual.

Remember that your servicing dealer knows your generator best andis fully equipped to maintain and repair it.

To ensure the best quality and reliability, use only new, HondaGenuine parts or their equivalents for repair and replacement.

10/10/12 14:35:22 31Z23800_040

Page 42: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

40

SERVICING YOUR GENERATOR

MAINTENANCE SAFETY

Safety Precautions

Carbon monoxide poisoning from engine exhaust.

Burns from hot parts.

Injury from moving parts.

Some of the most important safety precautions follow. However, wecannot warn you of every conceivable hazard that can arise inperforming maintenance. Only you can decide whether or not youshould perform a given task.

Failure to properly followmaintenance instructions andprecautions can cause you to beseriously hurt or killed.

Always follow the procedures andprecautions in the owner’s manual.

Make sure the engine is off before you begin any maintenance orrepairs. This will eliminate several potential hazards:

Operate outside away from open windows or doors.

Let the engine and exhaust system cool before touching.

Do not run the engine unless instructed to do so.

Read the instructions before you begin, and make sure you have thetools and skills required.

To reduce the possibility of fire or explosion, be careful whenworking around gasoline. Use only a non-flammable solvent, notgasoline, to clean parts. Keep cigarettes, sparks, and flames awayfrom all fuel-related parts.

10/10/12 14:35:30 31Z23800_041

Page 43: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

41

SERVICING YOUR GENERATOR

MAINTENANCE SCHEDULE

Every 2 years (Replace if necessary) (2)

Eachuse

(1)

Every 2 years (2)

ITEM

REGULAR SERVICE PERIOD (3)Perform at every indicated monthor operating hour interval,whichever comes first.

page

4445474953505052

Every 2 years (2)Every 2 years (2)

Engine oil

Air cleaner

Sediment cupSpark plug

Spark arresterIdle speedValve clearanceCombustionchamberFuel tank and filterFuel tubeCanisterPurge tubeCharge tube

Check levelChangeCheckCleanCleanCheck-adjustReplaceCleanCheck-adjustCheck-adjustClean

CleanCheckCheckCheckCheck

Service more frequently when used in dusty areas.

For commercial use, log hours of operation to determine proper maintenance intervals.

Failure to follow this maintenance schedule could result in non-warrantable failures.

These items should be serviced by your servicing dealer, unless you have the proper toolsand are mechanically proficient. Refer to the Honda shop manual for service procedures.

(2)(2)

(2)

After every 1,000 Hrs. (2)

(1)(2)

(3)

Firstmonth

or20 Hrs.

Every3

monthsor

50 Hrs.

Everyyearor

300 Hrs.

Every6

monthsor

100 Hrs.

10/10/12 14:35:43 31Z23800_042

Page 44: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

42

SERVICING YOUR GENERATOR

REFUELING

Gasoline is highly flammable andexplosive.

You can be burned or seriouslyinjured when handling fuel.

Stop the engine and keep heat,sparks, and flame away.Handle fuel only outdoors.Wipe up spills immediately.

Fuel can damage paint and plastic. Be careful not to spill fuel whenfilling your fuel tank. Damage caused by spilled fuel is not coveredunder warranty.

Refuel in a well-ventilated area before starting the engine. If the enginehas been running, allow it to cool. Refuel carefully to avoid spilling fuel.

Never refuel the engine inside a building where gasoline fumes mayreach flames or sparks. Keep gasoline away from appliance pilot lights,barbecues, electric appliances, power tools, etc.Spilled fuel is not only a fire hazard, it causes environmental damage.Wipe up spills immediately.

Do not fill above the upper level mark.

With the engine stopped, check the fuel gauge. Refill the fuel tank ifthe fuel level is low.

10/10/12 14:35:50 31Z23800_043

Page 45: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

43

SERVICING YOUR GENERATOR

FUEL RECOMMENDATIONS

FUEL LEVEL GAUGE

FUEL STRAINER

FUEL TANK CAP

EMPTYFULL

UPPER LEVEL MARK (RED)

UPPER LEVEL MARK (RED)

If your equipment will be used on an infrequent or intermittent basis,please refer to the fuel section of the STORAGE chapter (page ) foradditional information regarding fuel deterioration.

Engine damage or performance problems that result from using a fuelwith percentages of ethanol or methanol greater than shown aboveare not covered under warranty.

Use of fuels with content of ethanol or methanol greater than shownabove may cause starting and/or performance problems. It may alsodamage metal, rubber, and plastic parts of the fuel system.

You may use regular unleaded gasoline containing no more than 10%ethanol (E10) or 5% methanol by volume. In addition, methanol mustcontain cosolvents and corrosion inhibitors.

Never use stale or contaminated gasoline or an oil/gasoline mixture.Avoid getting dirt or water in the fuel tank.

This engine is certified to operate on regular unleaded gasoline with apump octane rating of 86 or higher.

After refueling, reinstall the fuel tank cap securely.

54

10/10/12 14:35:59 31Z23800_044

Page 46: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

44

SERVICING YOUR GENERATOR

ENGINE OIL LEVEL CHECK

UPPER LIMIT

OIL FILLER CAP/DIPSTICK

OIL FILLER HOLE

Check the oil level BEFORE EACH USE with the generator on a levelsurface and the engine stopped.

Remove the oil filler cap/dipstick and wipe it clean.

Insert and remove the dipstick without screwing it into the oil fillerhole. Check the oil level shown on the dipstick.

Screw in the oil filler cap/dipstick securely.

The Oil Alert system will automatically stop the engine before the oillevel falls below safe limits. However, to avoid the inconvenience of anunexpected shutdown, check the oil level regularly.

If the oil level is low, fill with the recommended oil to the upper limiton the oil filler cap/dipstick (see page ).

1.

2.

3.

4.

46

10/10/12 14:36:08 31Z23800_045

Page 47: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

×

×

×

45

SERVICING YOUR GENERATOR

ENGINE OIL CHANGE

UPPER LIMIT

OIL FILLER CAP/DIPSTICK 12 15 mmOIL DRAIN PLUG

SEALINGWASHER

Drain the oil while the engine is warm to assure rapid and completedraining.

Place a suitable container below the engine to catch the used oil,and then remove the oil filler cap/dipstick, 12 15 mm drain plug,and sealing washer.

Screw in the oil filler cap/dipstick securely.

Wash your hands with soap and water after handling used oil.

Improper disposal of engine oil can be harmful to the environment. Ifyou change your own oil, please dispose of it properly. Put it in asealed container, and take it to a recycling center. Do not discard it in atrash bin, dump it on the ground, or pour it down a drain.

Allow the used oil to drain completely, and then reinstall the 12 15mm drain plug and a new sealing washer. Tighten the plug securely.

With the generator in a level position, fill with the recommended oilto the upper limit on the oil filler cap/dipstick (see page ).

1.

2.

3.

4.

44

10/10/12 14:36:17 31Z23800_046

Page 48: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

46

SERVICING YOUR GENERATOR

ENGINE OIL RECOMMENDATIONS

AMBIENT TEMPERATURE

Oil is a major factor affecting performance and service life. Use4-stroke automotive detergent oil.

SAE 10W 30 is recommended for general use. Other viscositiesshown in the chart may be used when the average temperature inyour area is within the recommended range.

The SAE oil viscosity and service category are in the API label on theoil container. Honda recommends that you use API service categorySJ or later (or equivalent) oil.

10/10/12 14:36:22 31Z23800_047

Page 49: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

47

SERVICING YOUR GENERATOR

AIR CLEANER SERVICE

HOOK

SETTING PIN

CLIP

AIR CLEANER CASE

AIR CLEANER ELEMENT

FRAME PIPE

AIR CLEANER COVER

Unsnap the air cleaner cover clips and open the air cleaner cover.

Free the hooks from the setting pins on the air cleaner case andremove the air cleaner cover to the right side of the frame pipe,taking care not to damage the air cleaner cover.

Remove the air cleaner element from the air cleaner case.

Check the air cleaner element to be sure it is clean and in goodcondition.If the air cleaner element is dirty, clean it as described on page .Replace the air cleaner element if it is damaged.

3.

2.

1.

4.

49

10/10/12 15:51:05 31Z23800_048

Page 50: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

48

SERVICING YOUR GENERATOR

HOOK

SETTING PIN

CLIP

AIR CLEANER CASE

AIR CLEANER ELEMENT

AIR CLEANER COVER

NO GOODGOOD

Reinstall the air cleaner element in the air cleaner case.

Set the hooks of the air cleaner cover to the setting pins securely,and then push the air cleaner cover to lock the clips.Be sure that the cover is set securely. There must be no clearancebetween the air cleaner cover and air cleaner case.

Operating the engine without an air filter or with a damaged air filterwill allow dirt to enter the engine, causing rapid engine wear. This typeof damage is not covered by the Distributor’s Limited Warranty.

6.

5.

10/10/12 14:36:36 31Z23800_049

Page 51: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

49

SERVICING YOUR GENERATOR

AIR CLEANER ELEMENT CLEANING

A dirty air cleaner element will restrict air flow to the carburetor,reducing engine performance. If you operate the generator in verydusty areas, clean the air cleaner element more frequently thanspecified in the Maintenance Schedule.

Wash the air cleaner element in a solution of household detergentand warm water and rinse thoroughly, or wash in nonflammable orhigh flashpoint solvent. Allow the air cleaner element to drythoroughly.

Wipe dirt from the air cleaner housing and cover using a moist rag.Be careful to prevent dirt from entering the air duct that leads to thecarburetor.

Soak the air cleaner element in clean engine oil and squeeze out theexcess oil. The engine will smoke during initial startup if too muchoil is left in the air cleaner element.

3.

4. Squeeze1. Soak 3. Oil2. Squeeze to Dry

1.

2.

Do not twist. Do not twist.

10/10/12 14:36:42 31Z23800_050

Page 52: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

50

SERVICING YOUR GENERATOR

SPARK PLUG SERVICE

Recommended spark plugs:

SPARK PLUG WRENCH

SPARK PLUG CAP

In order to service the spark plug, you will need a spark plug wrench(commercially available).

To ensure proper engine operation, the spark plug must be properlygapped and free of deposits.

W16EPR-U (DENSO)BPR5ES (NGK)

An incorrect spark plug can cause engine damage.

If the engine is hot, allow it to cool before servicing the spark plug.

Disconnect the spark plug cap, and remove any dirt from around thespark plug area.

Remove the spark plug with a spark plug wrench.

1.

2.

10/10/12 14:36:51 31Z23800_051

Page 53: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

- -

- -

51

SERVICING YOUR GENERATOR

SEALING WASHER

0.028 0.031 in (0.7 0.8 mm)

SIDE ELECTRODE

Measure the spark plug electrode gap with a wire-type feeler gauge.Correct the gap, if necessary, by carefully bending the side electrode.

Visually inspect the spark plug. Replace it if the electrodes are wornor if the insulator is cracked, chipped, or fouled.

0.028 0.031 in (0.7 0.8 mm)

Attach the spark plug cap.

A loose spark plug can overheat and damage the engine.Overtightening the spark plug can damage the threads in the cylinderhead.

If installing a new spark plug, tighten 1/2 turn after the spark plugseats to compress the washer. If reinstalling a used spark plug,tighten 1/8 1/4 turn after the spark plug seats to compress thewasher.

After the spark plug is seated, tighten with a spark plug wrench tocompress the washer.

Check that the spark plug sealing washer is in good condition, andthread the spark plug in by hand to prevent cross-threading.

The gap should be:

3.

4.

5.

6.

7.

10/10/12 14:36:58 31Z23800_052

Page 54: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

52

SERVICING YOUR GENERATOR

SPARK ARRESTER SERVICE

5 mm SCREWS

SPARK ARRESTER SCREEN

SPARK ARRESTER

The spark arrester must be serviced every 100 hours to keep itfunctioning as designed.

If the engine has been running, the muffler will be very hot. Allow themuffler to cool before servicing the spark arrester.

Clean the spark arrester as follows:

Remove the two 5 mm screws, and remove the spark arrester.

Use a brush to remove carbon deposits from the spark arresterscreen.Be careful to avoid damaging the screen.The spark arrester must be free of breaks and tears. Replace thespark arrester if it is damaged.

Install the spark arrester in the reverse order of removal.

1.

3.

2.

10/10/12 14:37:07 31Z23800_053

Page 55: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

53

SERVICING YOUR GENERATOR

SEDIMENT CUP CLEANING

FUEL VALVE LEVER

SEDIMENT CUP

OOFFFF

O-RING(Replace)

The sediment cup prevents dirt or water that may be in the fuel tankfrom entering the carburetor. If the engine has not been run for a longtime, the sediment cup should be cleaned.

Turn the engine switch to the OFF position.

Gasoline is highly flammable andexplosive.

You can be burned or seriouslyinjured when handling fuel.

Stop the engine and keep heat,sparks, and flame away.Handle fuel only outdoors.Wipe up spills immediately.

Turn the fuel valve lever to theOFF position; then remove thesediment cup and the O-ring.Discard the O-ring.

Clean the sediment cup innonflammable solvent, and dryit thoroughly.

Reinstall the new O-ring andsediment cup, and tighten thesediment cup securely.

Turn the fuel valve lever to theON position and check for leaks.

1.

2.

5.

4.

3.

10/10/12 14:37:15 31Z23800_054

Page 56: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

54

STORAGE PREPARATION

Cleaning

Fuel

STORAGE

Proper storage preparation is essential for keeping your generatortrouble-free and looking good. The following steps will help to keeprust and corrosion from impairing your generator’s function andappearance, and will make the engine easier to start when you use thegenerator again.

Wipe the generator with a moist cloth. After the generator has dried,touch up any damaged paint, and coat other areas that may rust with alight film of oil.

You can extend fuel storage life by adding a gasoline stabilizer that isformulated for that purpose, or you can avoid fuel deteriorationproblems by draining the carburetor, sediment cup, and/or fuel tank.

The does not cover fuel system damage orengine performance problems resulting from neglected storagepreparation.

The length of time that gasoline can be left in your fuel tank andcarburetor without causing functional problems will vary with suchfactors as gasoline blend, your storage temperatures, and whether thefuel tank is partially or completely filled. The air in a partially filled fueltank promotes fuel deterioration. Very warm storage temperaturesaccelerate fuel deterioration. Fuel deterioration problems may occurwithin a few months, or even less if the gasoline was not fresh whenyou filled the fuel tank.

Gasoline will oxidize and deteriorate in storage. Old gasoline willcause hard starting, and it leaves gum deposits that clog the fuelsystem. If the gasoline in your generator deteriorates during storage,you may need to have the carburetor and other fuel systemcomponents serviced or replaced.

Depending on the region where you operate your equipment, fuelformulations may deteriorate and oxidize rapidly. Fuel deteriorationand oxidation can occur in as little as 30 days and may cause damageto the carburetor and/or fuel system. Please check with your servicingdealer for local storage recommendations.

Distributor’s Limited Warranty

10/10/12 14:37:23 31Z23800_055

Page 57: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

55

STORAGE

STORAGE TIME RECOMMENDED SERVICE PROCEDURE TOPREVENT HARD STARTING

Service according to the table below:

Less than 1 month1 to 2 months

2 months to 1 year

1 year or more

Use gasoline stabilizers that are formulated to extend storage life.Follow the manufacturer’s instructions for use.Contact your authorized Honda generator dealer for stabilizerrecommendations.

No preparation requiredFill with fresh gasoline and add gasolinestabilizer *.Fill with fresh gasoline and add gasolinestabilizer *.Drain the carburetor float bowl (page 56 ).Drain the fuel sediment cup (page 53 ).Fill with fresh gasoline and add gasolinestabilizer *.Drain the carburetor float bowl (page 56 ).Drain the fuel sediment cup (page 53 ).Remove the spark plug. Put a teaspoon ofengine oil into the cylinder. Turn the engineslowly with the pull rope to distribute the oil.Reinstall the spark plug.Change the engine oil (page 45 ).After removal from storage, drain the storedgasoline into a suitable container, and fill withfresh gasoline before starting.

*

10/10/12 14:37:28 31Z23800_056

Page 58: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

56

STORAGE

Draining the Fuel Tank and Carburetor

DRAIN SCREW

Gasoline is highly flammable andexplosive.

You can be burned or seriouslyinjured when handling fuel.

Stop the engine and keep heat,sparks, and flame away.Handle fuel only outdoors.Wipe up spills immediately.

Place a suitable gasoline container below the carburetor, and use afunnel to avoid spilling fuel.

Turn the fuel valve lever to the OFF position.

Loosen the carburetor drain screw and drain the gasoline from thecarburetor.

1.

2.

3.

10/10/12 14:37:35 31Z23800_057

Page 59: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

57

STORAGE

Engine Oil

ON

FUEL VALVE LEVER

After all the gasoline has drained into the container, tighten thedrain screw securely.

Place a suitable gasoline container below the sediment cup, and usea funnel to avoid spilling gasoline.

Remove the sediment cup (see page ), and then turn the fuelvalve lever to the ON position.

Allow the gasoline to drain completely, and then install the sedimentcup (see page ).

Slowly pull the starter grip until resistance is felt. At this point, thepiston is coming up on its compression stroke, and both the intakeand exhaust valves are closed. Storing the engine in this positionwill help to protect it from internal corrosion.

Change the engine oil (see page 45).

Remove the spark plug, and pour between one and two teaspoons(5 cc) of clean engine oil into the cylinder. Crank the engine severalrevolutions to distribute the oil, then reinstall the spark plug.

2.

1.

3.

4.

5.

6. 53

537.

10/10/12 14:37:42 31Z23800_058

Page 60: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

58

STORAGE

STORAGE PRECAUTIONS

REMOVAL FROM STORAGE

If your generator will be stored with gasoline in the fuel tank andcarburetor, it is important to reduce the hazard of gasoline vaporignition.

If possible, avoid storage areas with high humidity, because thatpromotes rust and corrosion.

Also avoid any area with a spark-producing electric motor, or wherepower tools are operated.

Select a well ventilated storage area away from any appliance thatoperates with a flame, such as a furnace, water heater, or clothes dryer.

With the engine and exhaust system cool, cover the generator to keepout dust. A hot engine and exhaust system can ignite or melt somematerials.

Do not use sheet plastic as a dust cover. A nonporous cover will trapmoisture around the generator, promoting rust and corrosion.

Check your generator as described in the BEFORE OPERATION chapterof this manual (see page ).

If the cylinder was coated with oil during storage preparation, theengine may smoke briefly at startup. This is normal.

Place the generator on a level surface. Tilting or laying it on its sidecan cause fuel or oil leakage.

Unless all fuel has been drained from the fuel tank, leave the engineswitch in the OFF position, and the fuel valve lever in the OFF position(see page ) to reduce the possibility of leakage.

If the generator was stored for 1 year or longer, drain the fuel tank (seepage ) and refuel with fresh gasoline. If you keep a container ofgasoline for refueling, be sure that it contains only fresh gasoline.Gasoline oxidizes and deteriorates over time, causing hard starting.

30

24

56

10/10/12 14:37:51 31Z23800_059

Page 61: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

59

TRANSPORTING

To lift the generator

LIFTING HANGER

HANDLE BAR

Do not lay the generator on its side when moving, storing, oroperating it. Oil or fuel may leak and damage the engine or yourproperty.

If the generator has been running, allow the engine to cool for at least15 minutes before loading the generator on the transport vehicle. Ahot engine and exhaust system can burn you and can ignite somematerials.

Keep the generator level when transporting to reduce the possibility offuel leakage. Move the fuel valve lever to the OFF position. Do not usethe generator while it is being transported.

When using ropes or tie-down straps to secure the generator fortransportation, be sure to only use the frame bars as attachmentpoints. Do not fasten ropes or straps to any portions of the generatorbody or handle bar.

Lift the generator by the lifting hanger. Do not try to lift the generatorby any other part.

10/10/12 14:37:58 31Z23800_060

Page 62: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

60

TAKING CARE OF UNEXPECTED PROBLEMS

ENGINE WILL NOT START

Possible Cause Correction

Fuel valve lever OFF. Turn lever ON (p. 27).

Engine switch OFF. Turn engine switch to ON(p. 28).

Out of fuel. Refuel (p. 42).

Bad fuel; generator storedwithout treating or draininggasoline, or refueled with badgasoline.

Drain fuel tank and carburetor(p. 56).Refuel with fresh gasoline(p. 42).

Low oil level caused Oil Alertto stop engine.

Add oil (p. 44).Turn engine switch to OFF andthen restart the engine.

Spark plug faulty, fouled, orimproperly gapped.

Gap or replace spark plug(p. 50).

Spark plug wet with fuel(flooded engine).

Dry and reinstall spark plug.

Fuel filter restricted,carburetor malfunction,ignition malfunction, valvesstuck, etc.

Take the generator to anauthorized Honda servicingdealer, or refer to the shopmanual.

10/11/04 12:46:00 31Z23800_061

Page 63: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

61

TAKING CARE OF UNEXPECTED PROBLEMS

ENGINE LACKS POWER

Possible cause Correction

Air filter restricted. Clean or replace air filter(p. 47 49).

Bad fuel; generator storedwithout treating or draininggasoline, or refueled with badgasoline.

Drain fuel tank and carburetor(p. 56).Refuel with fresh gasoline(p. 42).

Fuel filter restricted,carburetor malfunction,ignition malfunction, valvesstuck, etc.

Take the generator to anauthorized Honda servicingdealer, or refer to the shopmanual.

10/11/04 12:46:07 31Z23800_062

Page 64: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

62

TAKING CARE OF UNEXPECTED PROBLEMS

Possible Cause Correction

NO POWER AT THE AC RECEPTACLES

Switch AC circuit breaker ON.AC circuit breaker left in theOFF position after starting.

Check AC load and reset ACcircuit protector (p. 14).

AC circuit protector tripped.

Faulty power tool orappliance.

Replace or repair power tool orappliance.Stop and restart the engine.

Internal circuit overheated. Stop the engine. Reduce theelectrical load. Wait a fewminutes for the internal circuitto cool down. Restart theengine.

Faulty generator. Take the generator to anauthorized Honda servicingdealer, or refer to the shopmanual.

10/11/04 12:46:16 31Z23800_063

Page 65: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

〈 〉

〈 〉

63

TAKING CARE OF UNEXPECTED PROBLEMS

NO ELECTRICITY AT THE AC RECEPTACLES

When the GFCI RESET button is extended

Unplug all appliancesand equipment, andinspect the GFCIoperation (see page ).

When the GFCI RESET button is not extended

Is the AC circuit breakerON?

Turn the AC circuit breakerON (see page ).

Is the AC circuit protectorON?

Reset the AC circuit protector(see page ).

Check the electricalappliance or equipmentfor any defects.

Take the generator to anauthorized Honda generatordealer.

Replace the electricalappliance or equipment.Take the electricalappliance or equipment toan electrical shop for repair.

Replace the electricalappliance or equipment.Take the electricalappliance or equipment toan electrical shop for repair.

Take the generator to anauthorized Honda generatordealer.

NO

YES

DEFECTS

NO DEFECTS

The GFCI RESET buttonis extended again.

YES

NO

The GFCI RESET buttonis not extended.

20

15

14

10/10/12 14:38:21 31Z23800_064

Page 66: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

64

Serial Number Location

TECHNICAL INFORMATION

ENGINE SERIAL NUMBER

FRAME SERIAL NUMBER

Record the frame serial number and date purchased in the spacesbelow. You will need this information when ordering parts and whenmaking technical or warranty inquiries.

Engine serial number:

Frame serial number:

Date purchased:

10/10/12 14:38:27 31Z23800_065

Page 67: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

65

TECHNICAL INFORMATION

Carburetor Modification for High Altitude Operation

At high altitude, the standard carburetor air-fuel mixture will be toorich. Performance will decrease, and fuel consumption will increase. Avery rich mixture will also foul the spark plug and cause hard starting.Operation at an altitude that differs from that at which this engine wascertified, for extended periods of time, may increase emissions.

High altitude performance can be improved by specific modificationsto the carburetor. If you always operate your generator at altitudesabove 5,000 feet (1,500 meters), have your authorized Honda servicingdealer perform this carburetor modification. This engine, whenoperated at high altitude with the carburetor modifications for highaltitude use, will meet each emission standard throughout its usefullife.

Even with carburetor modification, engine horsepower will decreaseabout 3.5% for each 1,000-foot (300-meter) increase in altitude. Theeffect of altitude on horsepower will be greater than this if nocarburetor modification is made.

When the carburetor has been modified for high altitude operation,the air/fuel mixture will be too lean for low altitude use. Operation ataltitudes below 5,000 feet (1,500 meters) with a modified carburetormay cause the engine to overheat and result in serious engine damage.For use at low altitudes, have your servicing dealer return thecarburetor to original factory specifications.

10/10/12 14:38:31 31Z23800_066

Page 68: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

66

TECHNICAL INFORMATION

Emission Control System Information

Source of Emissions

The U.S. and California Clean Air Acts

Tampering and Altering

The combustion process produces carbon monoxide, oxides ofnitrogen, and hydrocarbons. Control of hydrocarbons and oxides ofnitrogen is very important because, under certain conditions, theyreact to form photochemical smog when subjected to sunlight. Carbonmonoxide does not react in the same way, but it is toxic.

Honda utilizes appropriate air/fuel ratios and other emissions controlsystems to reduce the emissions of carbon monoxide, oxides ofnitrogen, and hydrocarbons.

EPA and California regulations require all manufacturers to furnishwritten instructions describing the operation and maintenance ofemission control systems.

The following instructions and procedures must be followed in orderto keep the Honda engine emissions within the emission standards.

Additionally, Honda fuel systems utilize components and controltechnologies to reduce evaporative emissions.

Tampering with or altering the emission control system may increaseemissions beyond the legal limit. Among those acts that constitutetampering are:

Removal or alteration of any part of intake, fuel, or exhaust systems.

Altering or defeating the governor linkage or speed-adjustingmechanism to cause the engine to operate outside its designparameters.

10/10/12 14:38:39 31Z23800_067

Page 69: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

67

TECHNICAL INFORMATION

Problems That May Affect Emissions

Replacement Parts

Maintenance

If you are aware of any of the following symptoms, have your engineinspected and repaired by your authorized Honda servicing dealer.

Hard starting or stalling after starting.

Rough idle.

Misfiring or backfiring under load.

Afterburning (backfiring).

Black exhaust smoke or high fuel consumption.

Follow the MAINTENANCE SCHEDULE on page . Remember thatthis schedule is based on the assumption that your machine will beused for its designed purpose. Sustained high-load or high-temperature operation, or use in dusty conditions, will require morefrequent service.

The emission control systems on your new Honda engine weredesigned, built, and certified to conform with applicable emissionregulations. We recommend the use of Honda Genuine partswhenever you have maintenance done. These original-designreplacement parts are manufactured to the same standards as theoriginal parts, so you can be confident of their performance. The useof replacement parts that are not of the original design and qualitymay impair the effectiveness of your emission control system.

A manufacturer of an aftermarket part assumes the responsibility thatthe part will not adversely affect emission performance. Themanufacturer or rebuilder of the part must certify that use of the partwill not result in a failure of the engine to comply with emissionregulations.

41

10/10/12 14:38:45 31Z23800_068

Page 70: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

68

TECHNICAL INFORMATION

Air Index

An Air Index Information label is applied to engines certified to anemission durability time period in accordance with the requirementsof the California Air Resources Board.

The bar graph is intended to provide you, our customer, the ability tocompare the emissions performance of available engines. The lowerthe Air Index, the less pollution.

The durability description is intended to provide you with informationrelating to the engine’s emission durability period. The descriptiveterm indicates the useful life period for the engine’s emission controlsystem. See your Emission Control System Warranty for additionalinformation.

Descriptive Term Applicable to Emission Durability PeriodModerate

Intermediate

Extended

50 hours (0 80 cc, inclusive)125 hours (greater than 80 cc)125 hours (0 80 cc, inclusive)250 hours (greater than 80 cc)300 hours (0 80 cc, inclusive)500 hours (greater than 80 cc)

1,000 hours (225 cc and greater)

10/10/12 14:38:53 31Z23800_069

Page 71: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

±±

〔 × 〕 〔 ×× 〕

- -

〔 ×× 〕

69

TECHNICAL INFORMATION

Specifications

Tuneup

ITEM SPECIFICATION MAINTENANCE

Generator

Engine

Dimensions

Specifications may vary according to the types, and are subject tochange without notice.

·

AT type

IN: 0.15 0.02 mmEX: 0.20 0.02 mm

No other adjustments needed.

EB6500XEB4000X

EBPC

EB5000X

EBLCEBSC

Spark plug gapValve clearance (cold)

Other specifications

Refer to page 51

ModelType

ACoutput

4.0 kVA 5.0 kVA 6.5 kVA3.6 kVA 4.5 kVA 5.5 kVA

30.0 A/15.0 A 37.5 A/18.8 A 45.8 A/22.9 A60 Hz

120 V/240 VAT type

ModelEngine typeDisplacementBore Stroke

Compression ratioEngine speedCooling systemIgnition systemOil capacityFuel tank capacitySpark plug BPR5ES (NGK) W16EPR-U (DENSO)

6.21 US gal (23.5 L)1.2 US qt (1.1 L)

CDI magnetoForced air3,600 rpm

8.5:1 8.2:1

23.7 cu-in (389 cm )3.46 2.52 in

(88.0 64.0 mm)

4-stroke, overhead valve, single cylinderiGX390iGX270

ModelTypeDescription codeLength

WidthHeightDry mass [weight] 212.3 lbs

(96.3 kg)222.4 lbs(100.9 kg)

30.4 in (773 mm)27.8 in (706 mm)

41.4 in(1,051 mm)

41.1 in(1,043 mm)

188.3 lbs(85.4 kg)

Rated voltage

Rated currentRated output

EB4000X EB5000X EB6500X

0.028 0.031 in (0.7 0.8 mm)See your authorizedHonda dealer.

Rated frequency

Maximum output

16.5 cu-in (270 cm )

3.03 2.28 in

(77.0 58.0 mm)

10/10/12 14:39:16 31Z23800_070

Page 72: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

70

TECHNICAL INFORMATION

Wiring Diagram

Abbreviations Wire color code

SymbolAC OAC CBAuSwCBBCTD-AVR

D-CDIECUESwEgBEX WFrBFWGeBGFCI

GNDGTJ/BMWOLSwPoCSPVSSw

Part nameAC OutletAC Circuit BreakerAuto Throttle SwitchControl Box BlockCurrent TransformerDigital-AutomaticVoltage RegulatorDigital-CDIEngine Control UnitEngine SwitchEngine BlockExciter WindingFrame BlockField WindingGenerator BlockGround Fault CircuitInterrupterGroundGround TerminalJunction BoxMain WindingOil Level SwitchPower CoilSpark PlugVoltage SelectorSwitch

BlYBuGRWBrLgGrLbOP

BLACKYELLOWBLUEGREENREDWHITEBROWNLIGHT GREENGRAYLIGHT BLUEORANGEPINK

IGN E

Engine Switch

OFFON

10/10/12 14:39:23 31Z23800_071

Page 73: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

* *

71

TECHNICAL INFORMATION

EB4000X: 1 · EB5000X, EB6500X: 2

10/10/12 14:39:33 31Z23800_072

Page 74: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

72

Dealer Locator Information

Honda Publications

Shop Manual

Parts Catalog

Accessories Catalog

CONSUMER INFORMATION

To find an authorized Honda Servicing Dealer anywhere in the UnitedStates, visit our website: www.hondapowerequipment.com/dealerlocator/

This manual covers complete maintenance and overhaul procedures.It is intended to be used by a skilled technician.Available through your Honda dealer or through Helm Inc. at1 (888) 292-5395 or visit www.hondapowerequipment.com/products/manuals/

This manual provides complete, illustrated parts lists. Availablethrough your Honda dealer.

Your authorized Honda power equipment dealer offers a wideselection of accessories (optional equipment) to make your generatoreven more useful.Visit www.hondapowerequipment.com/products/accessories/and click on Generators and Welders to see the entire catalog ofaccessories.

10/10/12 14:39:41 31Z23800_073

Page 75: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

73

CONSUMER INFORMATION

Customer Service Information

Honda Power Equipment dealership personnel are trainedprofessionals. They should be able to answer any question you mayhave. If you encounter a problem that your dealer does not solve toyour satisfaction, please discuss it with the dealership’s management.The Service Manager or General Manager can help. Almost allproblems are solved in this way.

If you are dissatisfied with the decision made by the dealership’smanagement, contact the Honda Power Equipment CustomerRelations Office. You can write:

American Honda Motor Co., Inc.Power Equipment DivisionCustomer Relations Office4900 Marconi DriveAlpharetta, Georgia 30005-8847

When you write or call, please give us this information:

Model and serial numbers (see page )Name of the dealer who sold the generator to youName and address of the dealer who services your generatorDate of purchaseYour name, address, and telephone numberA detailed description of the problem

Or telephone: (770) 497-6400 8:30 am to 7:00 pm ET

64

10/10/12 14:39:46 31Z23800_074

Page 76: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

74

SAFETY

The Importance of Proper Assembly

ASSEMBLY

Improper assembly can cause anunsafe condition that can lead toserious injury or death.

Follow the procedures andprecautions in the assemblyinstructions carefully.

Proper assembly is essential to operator safety and the reliability ofthe machine. Any error or oversight made by the person assemblingand servicing a unit can easily result in faulty operation, damage to themachine, or injury to the operator.

Some of the most important safety precautions are given below.However, we cannot warn you of every conceivable hazard that canarise in performing this assembly. Only you can decide whether or notyou should perform a given task.

Failure to properly followinstructions and precautions cancause you to be seriously hurt orkilled.

Follow the procedures andprecautions in this manual carefully.

10/10/12 14:39:52 31Z23800_075

Page 77: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

75

ASSEMBLY

Important Safety Precautions

Injury from moving parts.

Burns from hot parts.

Carbon monoxide poisoning from engine exhaust.

Make sure you have a clear understanding of all basic shop safetypractices and that you are wearing appropriate clothing and safetyequipment. When performing this assembly, be especially careful ofthe following:

Read the instructions before you begin, and be sure you havethe tools and skills required to perform the tasks safely.

Make sure the engine is off before you begin any assembly,maintenance, or repairs. This will help eliminate several potentialhazards:

To reduce the possibility of a fire or explosion, be careful whenworking around gasoline or batteries. Use only a non-flammablesolvent, not gasoline, to clean parts. Keep all cigarettes, sparks, andflames away from all fuel-related parts.

Do not run the engine unless the instruction tells you to do so.Even then, keep your hands, fingers, and clothing away. Do notrun the engine when any protective guard or shield is removed.

Let the engine and exhaust system cool before touching.

Operate outside away from open windows or doors.

10/10/12 14:39:59 31Z23800_076

Page 78: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

×

×

×

76

ASSEMBLY

ASSEMBLY

Unpacking

Loose Parts (Wheel kit, handle and hanger)

Remove the generator and loose parts box from the carton.

Compare the loose parts with the inventory list below.

Tools Required:

Check all loose parts against the following list. Contact your dealer ifany of the loose parts shown below are not included with yourgenerator.

1.

2.

12 mm wrench (2), pliers

Ref. No.123456789101112131415

DescriptionWheelAxle ShaftHandle AssemblyHandle Lower BracketHandle Bush BHandle Bush AStandHangerHanger Bracket8 16 mm Flange bolt20 mm Plain Washer4.0 28 mm Split pin8 mm Flange nutHandle Folder Assembly8 18 mm Flange bolt

Qty.2112222122022412

10/10/12 14:40:10 31Z23800_077

Page 79: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

- - -

×

×

×

×

77

ASSEMBLY

Wheel Kit Installation

TORQUE:

WHEEL (2)

STAND (2)

GENERATORSIDE

20 mmPLAIN WASHER (2)

8 16 mm FLANGE BOLT (8)

4 28 mmSPLIT PIN (2)

8 mm FLANGE NUT (4)

AXLE SHAFT

SHORTER

UNDER FRAME

17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)

Apply grease to the axle shaft as shown below, and install the twowheels on the axle shaft using the washers and split pins.

Install the axle assembly on the generator using four 8 16 mmflange bolts and 8 mm flange nuts.

Install the two stands on the under frame using four 8 16 mmflange bolts.

1.

2.

3.

10/10/12 14:40:17 31Z23800_078

Page 80: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

×

×

- - -×

×

78

ASSEMBLY

Handle Installation

To extend handle:

TORQUE:

HANDLE ASSEMBLY

HANDLE

HANDLE LOCK LEVER

8 18 mm FLANGE BOLT (2)

FRAME PIPEHANDLE BUSH A (2)

HANDLE BUSH B (2)

HANDLE FOLDER ASSEMBLY

8 16 mm FLANGE BOLT (8)

HANDLE LOWER BRACKET (2)

Install the handle folder assembly on the generator upper frameusing the 8 18 mm flange bolts.Install the handle assembly on the generator upper frame pipe usingthe 8 16 mm flange bolts, handle bush A, handle bush B, andhandle lower bracket.

Raise the handle to the horizontal position. The handle will click intoplace when locked.

17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)

Operation must be checked after attaching the handle.Check that the handle can be folded smoothly.Check that the handle does not hang down by its own weight.

1.

2.

10/10/12 14:40:26 31Z23800_079

Page 81: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

- - -

×

79

ASSEMBLY

Hanger Kit Installation

TORQUE:

HANGER

HANGER

GENERATORSIDE

HANGER BRACKET (2)

8 16 mm FLANGE BOLT (4)

11 in (280 mm)

17 22 lbf·ft (24 29 N·m , 2.4 3.0 kgf·m)

Position the hanger at the generator’s balance point as shown below.

Fit the end tabs of the hanger through the bracket slots, and bolt thebrackets to the hanger and tighten securely.

1.

2.

10/10/12 14:40:33 31Z23800_080

Page 82: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

80

INITIAL USE INSTRUCTIONS

WITHOUT OIL

ENGINE OIL

Do not overfill the engine with oil.

UPPER LIMIT

OIL FILLER CAP/DIPSTICK

OIL FILLER HOLE

Place the generator on a level surface.

The generator is shipped in the engine.

Remove the oil filler cap/dipstick.

If the engine is overfilled, theexcess oil may be transferred to the air cleaner housing and air filter.

Screw in the oil filler cap/dipstick securely.

Add enough SAE 10W-30 API service category SJ or later (orequivalent) oil to bring the oil level to the upper limit on the oil fillercap/dipstick. SAE 10W-30 oil is recommended for general use; foradditional recommendations, see page .

1.

2.

3.

4.

46

10/10/12 14:40:41 31Z23800_081

Page 83: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

81

INITIAL USE INSTRUCTIONS

FUEL

UPPER LEVEL MARK (RED)

FUEL STRAINERFUEL TANK CAP UPPER LEVEL MARK (RED)

Stop the engine and keep heat,sparks, and flame away.Handle fuel only outdoors.Wipe up spills immediately.

Add fuel to the generator in a well-ventilated area. Never refuel theengine inside a building where gasoline fumes may reach flames orsparks. Keep gasoline away from appliance pilot lights, barbecues,electric appliances, power tools, etc. Spilled fuel is not only a firehazard, it causes environmental damage. Wipe up spills immediately.

This engine is certified to operate on unleaded gasoline with a pumpoctane rating of 86 or higher. Refer to page for additional fuelrecommendations.

Gasoline is highly flammable andexplosive.

You can be burned or seriouslyinjured when handling fuel.

Remove the fuel tank cap.

After refueling, reinstall the fuel tank cap securely.

Fuel carefully to avoid spilling fuel. Do not fill the fuel tank above theupper level mark (red) on the fuel strainer.

1.

2.

3.

42

10/10/12 14:40:50 31Z23800_082

Page 84: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

82

INITIAL USE INSTRUCTIONS

BEFORE OPERATION

GENERATOR SAFETY

CONTROLS & FEATURES

BEFORE OPERATION

OPERATION

STARTING THE ENGINE

STOPPING THE ENGINE

MAINTENANCE SCHEDULE

REGISTRATION

Please Register Your Generator

Fuel can damage paint and plastic. Be careful not to spill fuel whenfilling your fuel tank. Damage caused by spilled fuel is not coveredunder warranty.

Move the generator at least 10 feet (3 meters) away from the fuelingsource and site before starting the engine.

Before using the generator, all generator operators must read thefollowing chapters and sections:

(pages )

(pages )

(pages )

(page )

(pages )

(page )

(page )

If your dealer did not collect registration information from you, pleasetake a few minutes and register your purchase with Honda. This allowsus to contact you with any important updates regarding yourgenerator. Please note registration is not required to obtain warrantyservice. You can register your generator by visiting the Honda PowerEquipment website, www.hondapowerequipment.com and selectingProduct Registration. Your information will remain confidential. It willnot be released to any other company or organization.

6 9

10 23

24 25

26

27

30

41

29

10/10/12 14:40:58 31Z23800_083

Page 85: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

83

INDEX

A

B

C

D................................................................Dealer Locator Information . 72

....................................................................BEFORE OPERATION . 24, 82

..................................................................Carbon Monoxide Hazards . 6......................Carburetor Modification for High Altitude Operation . 65

................................................................................Check the Engine . 25...............................................................................................Cleaning . 54

..........................................COMPONENT & CONTROL LOCATIONS . 10.................................Connections to a Building’s Electrical System . 37

..............................................................CONSUMER INFORMATION . 72............................................................................................CONTENTS . 3..........................................................................................CONTROLS . 12

..................................................................CONTROLS & FEATURES . 10..........................................................Customer Service Information . 73

..............................................Abnormal Voltage Detection Function . 17...................................................................................AC Applications . 32

..........................................................................AC Circuit Protectors . 14...............................................................................AC Circuit Breaker . 15

...................................................................................AC OPERATION . 31....................................................................AC Receptacle Selection . 33

................................................AIR CLEANER ELEMENT CLEANING . 49......................................................................AIR CLEANER SERVICE . 47

...............................................................................................Air Index . 68...............................................ARE YOU READY TO GET STARTED? . 24

..........................................................................................ASSEMBLY . 74......................................................Automatic Engine Stop Function . 17

........................................................AUTO THROTTLE SYSTEM . 14, 36.........................................Auto Choke and Throttle Control System . 18

10/10/12 14:41:03 31Z23800_084

Page 86: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

84

INDEX

F

G

H

I

E.........................................................................Electric Shock Hazards . 7

..............................................Emission Control System Information . 66.....................................................................ENGINE LACKS POWER . 61

......................................................................................Engine Oil . 57, 80.........................................................................ENGINE OIL CHANGE . 45

................................................................ENGINE OIL LEVEL CHECK . 44..................................................ENGINE OIL RECOMMENDATIONS . 46

.....................................................................................Engine Switch . 12.................................................................ENGINE WILL NOT START . 60

..........................................................................GENERATOR SAFETY . 6.............................................Ground Fault Circuit Interrupter (GFCI) . 20

.................................................................................Ground Terminal . 19

..............................................................................Handle Installation . 78........................................................................Hanger Kit Installation . 79

.............................................................................Honda Publications . 72

...........................................................................................FEATURES . 17..........................................................................Fire and Burn Hazards . 7

....................................................................................Folding Handle . 16.................................................................................................Fuel . 54, 81

..........................................................................................Fuel Gauge . 19.............................................................FUEL RECOMMENDATIONS . 43

..................................................................................Fuel Valve Lever . 13

........................................iAVR (Intelligent Auto Voltage Regulator) . 18................................................IMPORTANT SAFETY INFORMATION . 6

............................................................Important Safety Precautions . 75

............................................................INITIAL USE INSTRUCTIONS . 80............................................IS YOUR GENERATOR READY TO GO? . 24

10/10/12 14:41:09 31Z23800_085

Page 87: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

85

INDEX

M

O

Q

R

N

P

K

L

...........................................................................................Knowledge . 24

..........................................................................................Loose Parts . 76

....................................................................MAINTENANCE SAFETY . 40..............................................................MAINTENANCE SCHEDULE . 41

...................................NO ELECTRICITY AT THE AC RECEPTACLES . 63............................................NO POWER AT THE AC RECEPTACLES . 62

................................................................................Oil Alert Function . 17

................................................................................Oil Alert System . 17.........................................................................................OPERATION . 26

.......................................................................Operator Responsibility . 6..........................................................Overspeed Detection Function . 17

...................................................................Power Producing Circuits . 33

........................QUICK REFERENCE INFORMATION . Inside back cover

..........................................................................................REFUELING . 42...................................................................................Refuel With Care . 8

...................................................................................REGISTRATION . 82..............................................................REMOVAL FROM STORAGE . 58

10/10/12 14:41:17 31Z23800_086

Page 88: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

86

INDEX

S

T

W

U

V

...................................................SAFE OPERATING PRECAUTIONS . 26................................................................................................SAFETY . 74

................................................................SAFETY LABEL LOCATIONS . 9..............................................................................Safety Precautions . 40

...............................................................SEDIMENT CUP CLEANING . 53.....................................................................Serial Number Location . 64

.......................................................SERVICING YOUR GENERATOR . 39..............................................................SPARK ARRESTER SERVICE . 52

.......................................................................SPARK PLUG SERVICE . 50........................................................................Special Requirements . 38

......................................................................................Specifications . 69..............................................................................STANDBY POWER . 37

..........................................................................................Starter Grip . 12....................................................................STARTING THE ENGINE . 27....................................................................STOPPING THE ENGINE . 30

............................................................................................STORAGE . 54.................................................................STORAGE PRECAUTIONS . 58..................................................................STORAGE PREPARATION . 54

...................................................................................System Ground . 37

.................................TAKING CARE OF UNEXPECTED PROBLEMS . 60...............................................................TECHNICAL INFORMATION . 64

............................................THE IMPORTANCE OF MAINTENANCE . 39................................................The Importance of Proper Assembly . 74

.................................................................................TRANSPORTING . 59

............................................................................................Unpacking . 76

...............................................................Voltage Selector Switch . 13, 34

..........................................................................Wheel Kit Installation . 77...................................................................................Wiring Diagram . 70

10/10/12 14:41:22 31Z23800_087

Page 89: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

- -

QUICK REFERENCE INFORMATION

Fuel

Engine Oil

Spark Plug

Maintenance

Regular unleaded gasoline witha pump octane rating of 86 orhigherSAE 10W-30, API SJ or later (orequivalent), for general use(page 46)

Check engine oil level.Check air filter.Change engine oil.See Maintenance Schedule(page 41)

Type

Type

Type

Electrode GapBefore eachuseFirst 20 hoursSubsequent

BPR5ES (NGK)W16EPR-U (DENSO)0.028 0.031 in (0.7 0.8 mm)

10/10/12 14:41:28 31Z23800_088

Page 90: Owner’sManual - Northern ToolKeep this owner’s manual handy so that you can refer to it at any time. This owner’s manual is considered a permanent part of the generator and should

00X31-Z23-800031Z23800 AHM.35.2011.02

PRINTED IN U.S.A.Printed on

Recycled Paper © 2011 Honda Motor Co., Ltd.—All Rights Reserved

Owner’s ManualGENERATOR

EB4000X • EB5000X • EB6500X

See page 80 forInitial Use Instructions

C

M

Y

CM

MY

CY

CMY

K

EB4000-6500X Cover.ai 2/8/2011 11:10:02 AMEB4000-6500X Cover.ai 2/8/2011 11:10:02 AM