SELECTION CHART / dimensions UNITS in mm ESD5111 ESD5111T ESD5119 ESD5120 ESD5131 Standard Features EFC Reverse Acting Light Force Temperature Compensated EFC Forward Acting Soft Coupling Speed Detection Circuit 5.00 (127) Ø0.27 (7) 1.031 (26) 5.00 (127) FEATURES Simple Installation and Adjustability Auxiliary Accessory Input Idle Speed Circuit Adjustable PID 10 VDC Supply for Accessories 10 Amp Drive Circuit Isochronous, Droop, & Variable Speed Operation The ESD5100 Series speed control unit is designed to precisely control engine speed with rapid responses to transient load changes. The ESD is compatible with all GAC proportional actuators except the ACB2001 electric actuator since this high torque actuator also requires current limiting. Ruggedly built to withstand all engine environments, the ESD will control a wide variety of engines in an isochronous or droop mode. Simplicity of installation and adjustment was foremost in the design. OVERNORS MERICA ORP. C A G ® Speed Control Unit ESD5100 Series

OVERNORS MERICA Speed Control Unit CORP. ESD5100 Series · SELECTION CHART / dimensions UNITS in mm ESD5111 ESD5111T ESD5119 ESD5120 ESD5131 Standard Features EFC Reverse Acting Light

  • Upload
    ngodang

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OVERNORS MERICA Speed Control Unit CORP. ESD5100 Series · SELECTION CHART / dimensions UNITS in mm ESD5111 ESD5111T ESD5119 ESD5120 ESD5131 Standard Features EFC Reverse Acting Light

SELECTION CHART / dimensions UNITS

inmm

ESD5111

ESD5111T

ESD5119

ESD5120

ESD5131

StandardFeatures

EFC Reverse Acting

LightForce

TemperatureCompensated

EFC ForwardActing

SoftCoupling

SpeedDetection

Circuit

5.00(127)

Ø0.27(7)

1.031(26)

5.00(127)

FEATURES

Simple Installation and AdjustabilityAuxiliary Accessory InputIdle Speed CircuitAdjustable PID

10 VDC Supply for Accessories10 Amp Drive CircuitIsochronous, Droop, & Variable Speed Operation

The ESD5100 Series speed control unit is designed to precisely control engine speed with rapid responses to transient load changes. The ESD is compatible with all GAC proportional actuators except the ACB2001 electric actuator since this high torque actuator also requires current limiting. Ruggedly built to withstand all engine environments, the ESD will control a wide variety of engines in an isochronous or droop mode. Simplicity of installation and adjustment was foremost in the design.

OVERNORS

MERICA

ORP.CAG

®

Speed Control UnitESD5100 Series

Page 2: OVERNORS MERICA Speed Control Unit CORP. ESD5100 Series · SELECTION CHART / dimensions UNITS in mm ESD5111 ESD5111T ESD5119 ESD5120 ESD5131 Standard Features EFC Reverse Acting Light

Governors America Corp.720 Silver Street Agawam, MA 01001

Phone: 413.233.1888 Fax: [email protected] 8.13 PTI1000 D

© 2013 Governors America Corp. All rights reserved.

OPTIONSGAC ACTUATORS

GAC actuators incorporate fast response, multi voltage usage, and a field proven electromechanical design that allows for precise control when coupled with GAC’s speed control devices. All of GAC actuators are easy to install with no maintenance required.

Throttle BodyPump Mounted

Engine MountedUniversal

EnvironmentalOperating Temperature Range -40 ° F to +185 ° F (-40 ° C to +85 ° C) Relative Humidity up to 95% Vibration 1 G @ 20 - 100HzAll Surface Finishes Fungus Proof and Corrosion Resistant

ElectricalPower Supply

Polarity Power Consumption Actuator Current Range @ 77°F (25°C) Speed Signal Range Speed Signal

12 or 24 ±20% VDC Battery Systems(Transient and Reverse Voltage Protected)

Negative Ground (Case Isolated)100 mA (No Actuator Current)

10 Amps Continuous1.0 - 50 VAC

1.0 - 120 VRMS

PhysicalDimensions See front page Weight 1.2 lb (0.544 kg) Mounting Any Position, Vertically Preferred

Compliance / StandardsAgency CE Requirements / RoHS Compliance

SPECIFICATIONSPerformance

Isochronous Operation ±0.25% Speed Range 1 - 7.5 KHz Continuous Speed Drift with Temperature ±0.5% Idle Speed Adjust CW Min. 1200 Hz. Below Set Speed Idle Speed Adjust CW Min. 4100 Hz. Below Set Speed Droop Range 1 - 5% RegulationDroop Adj. Max. (K-L Jumpered) 875 Hz., ±75 Hz per 1.0 A change Droop Adj. Min. (K-L Jumpered) 15 Hz., ±6 Hz per 1.0 A change

Speed Trim Range ±200 HzRemote Variable Speed Range 500 - 3.7 Khz Terminal Sensitivity 115 Hz., ±15 Hz/Volt @ 5 KΩ Impedance

735 Hz., ±60 Hz/Volt @ 65 KΩ Impedance 148 Hz., ±10 Hz/Volt @ 1 MΩ Impedance

10 VDC Supply @ 20 mA Max

JLNP

ACCESSORIES

The Magnetic Speed Sensor detects when ring gear teeth, or other ferrous projections, pass the tip of the sensor. Electrical impulses are produced by the sensor’s internal coil and sent to the speed control unit. The signal from the magnetic speed sensor, teeth per second (Hz.), is directly proportional to engine speed. Speed sensors are available in various lengths in both U.S. and metric threads. Wire leads, military connectors, automotive connectors or stud terminals are also available. Over 30 styles currently available.

Magnetic Speed Pickups