Specifications subject to change without notice. 516 11 2601 03 2/17/11 13 SEER PACKAGE DUAL FUEL HEAT PUMP, 2.5 to 5 TONS 208/230360 (Three Phase) REFRIGERATION CIRCUIT Environmentally sound R410A refrigerant Scroll compressor standard on all models Copper tube/aluminum fin condenser and evaporator coils Dehumidification mode (airflow reduction) on all models EASY TO INSTALL AND SERVICE Installs easily on a rooftop or at ground level Easy threepanel accessibility for maintenance and installation Easily converts to down discharge applications Combination gas heating, heat pump heating, and electric cooling Low NOx units available BUILT TO LAST Induceddraft combustion and venting Prepainted steel cabinet Direct spark ignition High efficiency ECM indoor blower motor on all models Aluminized steel tubular heat exchanger on PDD3 models, Stainless Steel tubular heat exchanger on PDS3 models Vertical condenser fan discharge Full perimeter steel base rails High and low pressure switches provide added reliability for the compressor WARRANTY 10 year heat exchanger limited warranty 5 year compressor limited warranty 1 year parts limited warranty UNIT PERFORMANCE DATA Aluminized Steel Heat Exchanger Stainless Steel Heat Exchanger COOLING HEAT PUMP HEATING GAS HEATING Unit Dimensions Height x Width x Depth in (mm) Operating Weight lbs (kg) Capacity BTU/h SEER EER Capacity BTU/h HSPF Input BTU/h Efficiency AFUE % PDD330040H00*C PDS330040HGS*C 29,000 13.5 11.5 29,000 7.7 40,000 80.0 42 1 / 8 x48 3 / 16 x32 5 / 8 (1070x1224x829) 365 (165) PDD330060H00*C PDS330060HGS*C 29,000 13.5 11.5 29,000 7.7 60,000 80.0 42 1 / 8 x48 3 / 16 x32 5 / 8 (1070x1224x829) 365 (165) PDD336060H00*C PDS336060HGS*C 35,000 13.5 11.5 35,000 7.7 60,000 80.0 42 1 / 8 x48 3 / 16 x32 5 / 8 (1070x1224x829) 372 (168) PDD336090H00*C PDS336090HGS*C 35,000 13.5 11.5 35,000 7.7 90,000 79.3 42 1 / 8 x48 3 / 16 x32 5 / 8 (1070x1224x829) 372 (168)) PDD342060H00*C PDS342060HGS*C 40,000 13.2 11.5 40,000 7.7 60,000 78.5 44 3 / 4 x48 3 / 16 x44 1 / 8 (1137x1224x1123) 453 (205) PDD342090H00*C PDS342090HGS*C 40,000 13.2 11.5 40,000 7.7 90,000 80.4 44 3 / 4 x48 3 / 16 x44 1 / 8 (1137x1224x1123) 453 (205) PDD348090H00*C PDS348090HGS*C 47,000 13.5 11.5 46,500 7.7 90,000 80.4 44 3 / 4 x48 3 / 16 x44 1 / 8 (1137x1224x1123) 474 (215) PDD348115H00*C PDS348115HGS*C 47,000 13.5 11.5 46,500 7.7 115,000 80.3 44 3 / 4 x48 3 / 16 x44 1 / 8 (1137x1224x1123) 474 (215) PDD348130H00*C PDS348130HGS*C 47,000 13.5 11.5 46,500 7.7 130,000 78.9 44 3 / 4 x48 3 / 16 x44 1 / 8 (1137x1224x1123) 474 (215) PDD360090H00*C PDS360090HGS*C 57,000 13.5 11.5 57,000 7.7 90,000 80.4 48 3 / 4 x48 3 / 16 x44 1 / 8 (1238x1224x1123) 498 (226) PDD360115H00*C PDS360115HGS*C 57,000 13.5 11.5 57,000 7.7 115,000 80.3 48 3 / 4 x48 3 / 16 x44 1 / 8 (1238x1224x1123) 498 (226) PDD360130H00*C PDS360130HGS*C 57,000 13.5 11.5 57,000 7.7 130,000 78.9 48 3 / 4 x48 3 / 16 x44 1 / 8 (1238x1224x1123) 498 (226) * - 0 = Standard, 1 = Low NOx Use of the AHRI Certified TM Mark in- dicates a manufacturer’s participation in the program. For verification of certi- fication for individual products, go to www.ahridirectory.org . PDD3, PDS3 Product Specifications E N V I R O N M E N T A L L Y S O U N D R E F R I G E R A N T

OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

Specifications subject to change without notice. 516 11 2601 03 2/17/11

13 SEER PACKAGE DUAL FUEL HEAT PUMP, 2.5 to 5 TONS208/230−3−60 (Three Phase)

REFRIGERATION CIRCUIT• Environmentally sound R−410A refrigerant• Scroll compressor standard on all models• Copper tube/aluminum fin condenser and evaporator coils• Dehumidification mode (airflow reduction) on all models

EASY TO INSTALL AND SERVICE• Installs easily on a rooftop or at ground level• Easy three−panel accessibility for maintenance and installation• Easily converts to down discharge applications• Combination gas heating, heat pump heating, and electric cooling• Low NOx units available

BUILT TO LAST• Induced−draft combustion and venting• Pre−painted steel cabinet• Direct spark ignition• High efficiency ECM indoor blower motor on all models• Aluminized steel tubular heat exchanger on PDD3 models, Stainless Steel tubular

heat exchanger on PDS3 models• Vertical condenser fan discharge• Full perimeter steel base rails• High and low pressure switches provide added reliability for the compressor

WARRANTY• 10 year heat exchanger limited warranty• 5 year compressor limited warranty• 1 year parts limited warranty

UNIT PERFORMANCE DATA

Aluminized SteelHeat Exchanger

Stainless SteelHeat Exchanger

COOLING HEAT PUMP HEATING GAS HEATING Unit Dimensions Height x Width x Depth

in (mm)

OperatingWeightlbs (kg)

CapacityBTU/h SEER EER

CapacityBTU/h HSPF

InputBTU/h

EfficiencyAFUE %

PDD330040H00*C PDS330040HGS*C 29,000 13.5 11.5 29,000 7.7 40,000 80.0 421/8x483/16x325/8 (1070x1224x829) 365 (165)PDD330060H00*C PDS330060HGS*C 29,000 13.5 11.5 29,000 7.7 60,000 80.0 421/8x483/16x325/8 (1070x1224x829) 365 (165)PDD336060H00*C PDS336060HGS*C 35,000 13.5 11.5 35,000 7.7 60,000 80.0 421/8x483/16x325/8 (1070x1224x829) 372 (168)PDD336090H00*C PDS336090HGS*C 35,000 13.5 11.5 35,000 7.7 90,000 79.3 421/8x483/16x325/8 (1070x1224x829) 372 (168))PDD342060H00*C PDS342060HGS*C 40,000 13.2 11.5 40,000 7.7 60,000 78.5 443/4x483/16x441/8 (1137x1224x1123) 453 (205)PDD342090H00*C PDS342090HGS*C 40,000 13.2 11.5 40,000 7.7 90,000 80.4 443/4x483/16x441/8 (1137x1224x1123) 453 (205)PDD348090H00*C PDS348090HGS*C 47,000 13.5 11.5 46,500 7.7 90,000 80.4 443/4x483/16x441/8 (1137x1224x1123) 474 (215)PDD348115H00*C PDS348115HGS*C 47,000 13.5 11.5 46,500 7.7 115,000 80.3 443/4x483/16x441/8 (1137x1224x1123) 474 (215)PDD348130H00*C PDS348130HGS*C 47,000 13.5 11.5 46,500 7.7 130,000 78.9 443/4x483/16x441/8 (1137x1224x1123) 474 (215)PDD360090H00*C PDS360090HGS*C 57,000 13.5 11.5 57,000 7.7 90,000 80.4 483/4x483/16x441/8 (1238x1224x1123) 498 (226)PDD360115H00*C PDS360115HGS*C 57,000 13.5 11.5 57,000 7.7 115,000 80.3 483/4x483/16x441/8 (1238x1224x1123) 498 (226)PDD360130H00*C PDS360130HGS*C 57,000 13.5 11.5 57,000 7.7 130,000 78.9 483/4x483/16x441/8 (1238x1224x1123) 498 (226) * - 0 = Standard, 1 = Low NOx

Use of the AHRI Certified TM Mark in-dicates a manufacturer’s participationin the program. For verification of certi-fication for individual products, go towww.ahridirectory.org .

PDD3, PDS3Product SpecificationsENVIRONM

ENTA

LLY

SO

UN

DR

EFRIGERANT

Page 2: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE2 516 11 2601 03

MODEL NOMENCLATURE

MODEL SERIES

1 2 3 4 5,6 7,8,9 10 11,12 13 14 15

P D D 3 36 090 H 00 0 C 1P = Package

A = Air Conditioner

H = Heat Pump

G = Gas/Electric

D = Dual Fuel TYPED = Standard

S = Mainline w/ SS HX TIER

3 = 13

4 = 14 SEER30 = 30,000 BTUH = 2.5 Tons

36 = 36,000 BTUH = 3 Tons

42 = 42,000 BTUH = 3.5 Tons

48 = 48,000 BTUH = 4 Tons

60 = 60,000 BTUH = 5 Tons NOMINAL COOLING CAPACITY000 = no factory heat

040 = 40,000 BTU/hr

060 = 60,000 BTU/hr

090 = 90,000 BTU/hr

115 = 115,000 BTU/hr

130 = 130,000 BTU/hr NOMINAL HEATING BTUH (input)

H = 208/230−3−60 VOLTAGE

00 = No options

GS = Stainless Steel Heat Exchanger FACTORY INSTALLED OPTIONS0 = Standard

1 = Low NOx FEATURE CODESales Model Digit

Engineering Digit

AHRI* CAPACITIESCOOLING CAPACITIES AND EFFICIENCIES − PD(D,S)330−60

UNITPD(D,S)3 NOMINAL TONS STANDARD CFM

COOLINGCAPACITIES (Btuh) EER** SEER†

30 2-1/2 1000 29,000 11.5 13.536 3 1200 35,000 11.5 13.542 3-1/2 1400 40,000 11.5 13.248 4 1600 47,000 11.5 13.560 5 1850 57,000 11.5 13.5

HEAT PUMP HEATING CAPACITIES AND EFFICIENCIES − PD(D,S)330−60

UNITPD(D,S)3

HEATING CAPACITY (Btuh) @

47�F (8.3�C) COP @ 47�F (8.3�C)

HEATING CAPACITY (Btuh) @

17�F (-8.3�C)COP @ 17�F

(-8.3�C) HSPF†30 29,000 3.5 15,900 2.2 7.736 35,000 3.4 20,400 2.3 7.742 40,000 3.4 22,000 2.2 7.748 46,500 3.6 26,200 2.3 7.760 57,000 3.5 31,000 2.3 7.7

LEGENDdBA-Sound Levels (decibels)db—Dry BulbSEER—Seasonal Energy Efficiency Ratiowb—Wet BulbCOP-Coefficient of PerformanceHSPF-Heating Season Performance Factor* Air Conditioning, Heating, & Refrigeration Institute.**At “A” conditions-80�F (26.7�C) indoor db/67�F (19.4�C) indoor wb & 95�F(35�C) outdoor db.� Rated in accordance with U.S. Government DOE Department of Energy) testprocedures and/or ARI Standards 210/240.

Notes:1. Ratings are net values, reflecting the effects of circulating fan heat.Ratings are based on:Cooling Standard: 80°F (26.7�C) db, 67°F (19.4�C) wb indoor entering-airtemperature and 95°F (35�C) db outdoor entering-air temperature.2. Before purchasing this appliance, read important energy cost and efficiencyinformation available from your retailer.

Page 3: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 3516 11 2601 03

UNIT ELECTRICAL SPECIFICATIONSMODEL

NUMBERNOMINALV−PH−HZ

Voltage Range Compressor OFM IFM IDM Power SupplyMin. Max. RLA LRA FLA FLA FLA MCA MOCP

PDD330040 PDS330040

208/230­3­60

197 253 10.9 58 1.2 4.1 0.65 18.9 25PDD330060 PDS330060 197 253 10.9 58 1.2 4.1 1.65 18.9 25PDD336060 PDS336060 197 253 13 88 1.2 6 1.65 23.5 30PDD336090 PDS336090 197 253 13 88 1.2 6 0.52 23.5 30PDD342060 PDS342060 197 253 13.5 88 1.2 6 1.65 24.1 35PDD342090 PDS342090 197 253 13.5 88 1.2 6 0.65 24.1 35PDD348090 PDS348090 197 253 14.8 83.1 1.2 7.6 0.65 27.3 40PDD348115 PDS348115 197 253 14.8 83.1 1.2 7.6 1.65 27.3 40PDD348130 PDS348130 197 253 14.8 83.1 1.2 7.6 0.52 27.3 40PDD360090 PDS360090 197 253 18.4 110 1.2 7.6 0.65 31.8 45PDD360115 PDS360115 197 253 18.4 110 1.2 7.6 1.65 31.8 45PDD360130 PDS360130 197 253 18.4 110 1.2 7.6 0.52 31.8 45

228 = 1 v229 = 2 v227 = 2 v

LEGEND

FLA -- Full Load AmpsLRA -- Locked Rotor AmpsMCA -- Minimum Circuit AmpsMOCP -- Maximum Overcurrent ProtectionRLA -- Rated Load Amps

NO TES:1. In compliance with NEC (National Electrical Code) requirements

for multimotor and combination load equipment (refer to NE CArticles 430 and 440), the overcurrent protective device for theunit shall be Power Supply fuse. The CGA (Canadian GasAssociation) units may be fuse or circuit break er.

2. Minimum wire size is based on 60 C copper wire. I f other than60 C wire is used, or if length exceeds wire length in table,determine siz e from NEC..

3. Unbalanced 3-Phase Supply VoltageNever operate a motor where a phase imbalance in supply volt-age is greater than 2%. Use the following formula to determinethe percentage of voltage imbalance.

% Voltage imbalance

max voltage deviation from average voltage= 100 xaverage voltage

EXAMPLE: Supply voltage is 230-3-60.AB = 228 vBC = 231 vAC = 227 v

228 + 231 + 227Average Voltage =3

686=3

= 229

Determine maximum deviation from average voltage.(AB) 229 -(BC) 231 -(AC) 229 -

Maximum deviation is 2 v.

Determine percent of voltage imbalance.2% Voltage Imbalance = 100 x

229

= 0.8%

This amount of phase imbalance is satisfactory as it is below themaximum allowable 2%.

IMPORTANT: If the supply voltage phase imbalance ismore than 2%, contact your local electric utility companyimmediately.

(R)

GAS HEATING CAPACITIES AND EFFICIENCIES

UNIT PD(D,S)3 HEATING INPUT (Btuh)OUTPUT CAPACITY

(Btuh)TEMPERATURE RISE

RANGE �F (�C) AFUE (%)

30040 40,000 32,000 30−60 (16.7−33.3) 80.0

300603606042060

60,00048,00048,00047,000

25−55 (13.9−30.6)80.080.078.5

36090420904809060090

90,000

72,00073,00073,00073,000

35−65 (19.4−36.1)

79.380.480.480.4

4811500115 115,000 93,000 30−60 (16.7−33.3) 80.3

4813060130 130,000 103,000 35−65 (19.4−36.1) 78.9

LEGENDAFUE—Annual Fuel Utilization EfficiencyNOTE: Before purchasing this appliance, read important energy cost and efficiency information available from your retailer.

Page 4: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE4 516 11 2601 03

UNIT SPECIFICATIONS PD(D,S)330 − 42UNIT SIZE 30040 30060 36060 36090 42060 42090

NOMINAL CAPACITY (ton) 2-1/2 2-1/2 3 3 3-1/2 3-1/2

NOMINAL HEATING INPUT (Btu/hrs) 40,000 60,000 60,000 90,000 60,000 90,000

SHIPPING WEIGHT -lb. kg

373169

373169

379172

379172

461209

461209

COMPRESSORS Scroll

Quantity 1

REFRIGERANT (R-410A) Quantity -lb (kg

10.24.6

10.24.6

7.93.6

7.93.6

10.04.5

10.04.5

REFRIGERANT METERING DEVICE Indoor-TXV, Outdoor-Piston

OUTDOOR ORIFICE

in. (qty) mm

0.035 (2).89

0.037 (2).94

0.038 (Left)0.040(Right)

.97/1.02

OUTDOOR COIL Rows...Fins/in. Face Area-sq ft

2...2111.9

2...2111.9

2...2111.9

2...2111.9

2...2113.6

2...2113.6

OUTDOOR FAN Nominal Cfm Diameter-in. mmMotor Hp (Rpm)

2700 24610

1/5 (810)

270024610

1/5 (810)

270024610

1/5 (810)

270024610

1/5 (810)

310026660

1/5 (810)

310026660

1/5 (810)

INDOOR COIL Rows...Fins/in. Face Area-sq ft

3...17 3.7

3...17 3.7

3...17 3.7

3...17 3.7

3...17 4.7

3...17 4.7

INDOOR BLOWER Nominal Cooling Airflow-(CFM)Size-in. mmMotor -hp

100010x10

254x2541/2

1000 10x10

254x2541/2

1200 11x10

279x2543/4

120011x10

279x2543/4

140011x10

279x2543/4

140011x10

279x2543/4

FURNACE SECTION* Burner OrificeNatural Gas Qty...Drill Size (Factory Installed)Propane GasQty...Drill Size

2...442...55

2...382...53

2...382...53

3...383...53

2...382...53

3...383...53

HIGH-PRESSURE SWITCH (psig) Cut-out Reset (Auto)

650 +/-15420 +/-25

LOSS-OF-CHARGE / LOW-PRESSURE SWITCH (Liquid Line) (psig) Cut-out Reset (auto)

20 +/-545 +/-10

RETURN-AIR FILTERS † �Throwaway in. mm

20x24x1508x610x25

24x30x1610x762x25

*Based on altitude of 0 to 2000 ft (0-610 m).

�Required filter sizes shown are based on the larger of the AHRI (Air Conditioning, Heating, and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of300 ft/minute for high-capacity type. Air filter pressure drop for non-standard filters must not exceed 0.08 IN. W.C.� If using accessory filter rack refer to filter rack installation instructions for correct filter size and quantity.

Page 5: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 5516 11 2601 03

UNIT SPECIFICATIONS PD(D,S)348 − 60UNIT SIZE 48090 48115 48130 60090 60115 60130

NOMINAL CAPACITY (ton) 4 4 4 5 5 5

NOMINAL HEATING INPUT (Btu/hrs) 90,000 115,000 130,000 90,000 115,000 130,000

SHIPPING WEIGHT-lb kg

482219

482219

482219

507230

507230

507230

COMPRESSORS Scroll

Quantity 1

REFRIGERANT (R-410A) Quantity -lb kg

9.64.4

12.35.6

REFRIGERANT METERING DEVICE Indoor-TXV, Outdoor-Piston

OUTDOOR ORIFICE-in. (qty) mm

0.046 (2)1.2

0.052 (2)1.3

OUTDOOR COIL Rows...Fins-in.Face Area-sq ft

2...2113.6

2...2113.6

2...2113.6

2...2117.5

2...2117.5

2...2117.5

OUTDOOR FANNominal CfmDiameter-in. mmMotor Hp-Rpm

310026660

1/5 (810)

310026660

1/5 (810)

310026660

1/5 (810)

310026660

1/5 (810)

310026660

1/5 (810)

310026660

1/5 (810)

INDOOR COILRows...Fins-in.Face Area-sq ft

3...174.7

3...174.7

3...174.7

3...175.7

3...175.7

3...175.7

INDOOR BLOWERNominal Cooling Airflow-(CFM)Size-in. mmMotor -hp

160011x10

279x2541.0

160011x10

279x2541.0

160011x10

279x2541.0

185011x10

279x2541.0

185011x10

279x2541.0

185011x10

279x2541.0

FURNACE SECTION* Burner OrificeNatural Gas Qty...Drill Size (Factory Installed)Propane GasQty...Drill Size

3...383...53

3...333...51

3...313...49

3...383...53

3...333...51

3...313...49

HIGH-PRESSURE SWITCH (psig) Cut-out Reset (Auto)

650 +/-15420 +/-25

LOSS-OF-CHARGE /LOW-PRESSURE SWITCH (Liquid Line) (psig)Cut-out Reset (auto)

20 +/-545 +/-10

RETURN-AIR FILTERS †Throwaway in. mm

24x36x1610x914x25

*Based on altitude of 0 to 2000 ft (0-610 m).

�Required filter sizes shown are based on the larger of the AHRI (Air Conditioning, Heating, and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of300 ft/minute for high-capacity type. Air filter pressure drop for non-standard filters must not exceed 0.08 IN. W.C.� If using accessory filter rack refer to filter rack installation instructions for correct filter size and quantity.

A−WEIGHTED SOUND POWER LEVEL (dBA)

MODEL PD(D,S)3 STANDARD RATING (dBA)

TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment)125 250 500 1000 2000 4000 8000

30 76 60.5 67.5 72.0 70.0 67.0 61.0 51.5

36 77 63.0 68.0 73.0 71.0 67.0 62.0 55.0

42 78 65.0 68.5 74.5 72.5 69.5 64.5 56.5

48 78 62.0 68.5 74.0 72.5 70.0 64.0 56.0

60 76 63.0 66.5 69.5 71.0 66.0 65.0 59.0LEGENDdBA−Sound Levels (decibels)NOTE: Tested in accordance with AHRI Standard 270 (not listed in ARI).

Page 6: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE6 516 11 2601 03

DRY COIL AIR DELIVERY* − HORIZONTAL AND DOWNFLOW DISCHARGE

UNITHeating Rise

RangeMotorSpeed

WireColor

EXTERNAL STATIC PRESSURE (in wc)0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

PD(D,S)33004030 - 60oF

(17 - 33oC)

Low BlueCFM 741 638 547 415 -- -- -- -- --

Heating Rise (oF) 41 47 55 NA NA NA NA NA NAHeating Rise (oC) 23 26 31 NA NA NA NA NA NA

Med-Low1 PinkCFM 973 887 823 733 665 538 451 -- --

Heating Rise (oF) 31 34 37 41 45 56 NA NA NAHeating Rise (oC) 17 19 20 23 25 31 NA NA NA

Medium RedCFM 1088 1023 954 881 800 723 658 563 461

Heating Rise (oF) NA 30 32 34 38 42 46 54 NAHeating Rise (oC) NA 16 18 19 21 23 26 30 NA

Med-High2 OrangeCFM 1140 1064 996 915 840 758 687 564 480

Heating Rise (oF) NA NA 30 33 36 40 44 54 NAHeating Rise (oC) NA NA 17 18 20 22 24 30 NA

High BlackCFM 1202 1140 1082 1015 961 881 810 732 631

Heating Rise (oF) NA NA NA 30 31 34 37 41 48Heating Rise (oC) NA NA NA 17 17 19 21 23 27

PD(D,S)33006025 - 55oF

(14 - 31oC)

Low BlueCFM 741 638 547 415 -- -- -- -- --

Heating Rise (oF) NA NA NA NA NA NA NA NA NAHeating Rise (oC) NA NA NA NA NA NA NA NA NA

Med-Low PinkCFM 973 887 823 733 665 538 451 -- --

Heating Rise (oF) 46 50 54 NA NA NA NA NA NAHeating Rise (oC) 25 28 30 NA NA NA NA NA NA

Medium RedCFM 1088 1023 954 881 800 723 658 563 461

Heating Rise (oF) 41 43 47 50 NA NA NA NA NAHeating Rise (oC) 23 24 26 28 NA NA NA NA NA

Med-High2 OrangeCFM 1140 1064 996 915 840 758 687 564 480

Heating Rise (oF) 39 42 45 49 53 NA NA NA NAHeating Rise (oC) 22 23 25 27 29 NA NA NA NA

High1 BlackCFM 1202 1140 1082 1015 961 881 810 732 631

Heating Rise (oF) 37 39 41 44 46 50 55 NA NAHeating Rise (oC) 21 22 23 24 26 28 30 NA NA

PD(D,S)33606025 - 55oF

(14 - 31oC)

Low1 BlueCFM 1234 1168 1093 1021 961 894 825 759 687

Heating Rise (oF) 36 38 41 44 46 50 54 NA NAHeating Rise (oC) 20 21 23 24 26 28 30 NA NA

Med-Low PinkCFM 1290 1223 1154 1090 1027 977 894 828 762

Heating Rise (oF) 34 36 39 41 43 45 50 54 NAHeating Rise (oC) 19 20 21 23 24 25 28 30 NA

Medium2 RedCFM 1354 1290 1226 1158 1102 1046 981 918 843

Heating Rise (oF) 33 34 36 38 40 42 45 48 53Heating Rise (oC) 18 19 20 21 22 24 25 27 29

Med-High OrangeCFM 1606 1546 1489 1430 1371 1316 1258 1208 1140

Heating Rise (oF) 28 29 30 31 32 34 35 37 39Heating Rise (oC) 15 16 17 17 18 19 20 20 22

High BlackCFM 1630 1580 1517 1463 1407 1339 1277 1210 1131

Heating Rise (oF) 27 28 29 30 32 33 35 37 39Heating Rise (oC) 15 16 16 17 18 18 19 20 22

PD(D,S)33609035 - 65oF

(19 - 36oC)

Low BlueCFM 1234 1168 1093 1021 961 894 825 759 687

Heating Rise (oF) 55 58 62 NA NA NA NA NA NAHeating Rise (oC) 31 32 35 NA NA NA NA NA NA

Med-Low PinkCFM 1290 1223 1154 1090 1027 977 894 828 762

Heating Rise (oF) 53 56 59 62 NA NA NA NA NAHeating Rise (oC) 29 31 33 35 NA NA NA NA NA

Medium2 RedCFM 1354 1290 1226 1158 1102 1046 981 918 843

Heating Rise (oF) 50 53 55 59 62 65 NA NA NAHeating Rise (oC) 28 29 31 33 34 36 NA NA NA

Med-High OrangeCFM 1606 1546 1489 1430 1371 1316 1258 1208 1140

Heating Rise (oF) 42 44 46 48 50 52 54 56 60Heating Rise (oC) 24 24 25 26 28 29 30 31 33

High1 BlackCFM 1630 1580 1517 1463 1407 1339 1277 1210 1131

Heating Rise (oF) 42 43 45 46 48 51 53 56 60Heating Rise (oC) 23 24 25 26 27 28 30 31 33

Page 7: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 7516 11 2601 03

DRY COIL AIR DELIVERY* − HORIZONTAL AND DOWNFLOW DISCHARGE

UNITHeating Rise

RangeMotorSpeed

WireColor

EXTERNAL STATIC PRESSURE (in wc)0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

PD(D,S)34206025 - 55oF

(14 - 31oC)

Low1 BlueCFM 1295 1234 1182 1126 1075 1016 955 898 857

Heating Rise (oF) 34 36 38 39 41 44 47 49 52Heating Rise (oC) 19 20 21 22 23 24 26 27 29

Med-Low PinkCFM 1345 1282 1235 1194 1140 1095 1027 974 921

Heating Rise (oF) 33 35 36 37 39 41 43 46 48Heating Rise (oC) 18 19 20 21 22 23 24 25 27

Medium RedCFM 1505 1452 1413 1358 1323 1282 1234 1169 1130

Heating Rise (oF) 30 31 31 33 34 35 36 38 39Heating Rise (oC) 16 17 17 18 19 19 20 21 22

Med-High2 OrangeCFM 1545 1492 1449 1411 1362 1313 1278 1231 1188

Heating Rise (oF) 29 30 31 31 33 34 35 36 37Heating Rise (oC) 16 17 17 17 18 19 19 20 21

High BlackCFM 1705 1643 1607 1568 1518 1483 1448 1404 1360

Heating Rise (oF) 26 27 28 28 29 30 31 32 33Heating Rise (oC) 14 15 15 16 16 17 17 18 18

PD(D,S)34209035 - 65oF

(19 - 36oC)

Low BlueCFM 1295 1234 1182 1126 1075 1016 955 898 857

Heating Rise (oF) 53 55 58 60 63 NA NA NA NAHeating Rise (oC) 29 31 32 34 35 NA NA NA NA

Med-Low PinkCFM 1345 1282 1235 1194 1140 1095 1027 974 921

Heating Rise (oF) 51 53 55 57 60 62 NA NA NAHeating Rise (oC) 28 29 31 32 33 35 NA NA NA

Medium1 RedCFM 1505 1452 1413 1358 1323 1282 1234 1169 1130

Heating Rise (oF) 45 47 48 50 51 53 55 58 60Heating Rise (oC) 25 26 27 28 29 29 31 32 33

Med-High2 OrangeCFM 1545 1492 1449 1411 1362 1313 1278 1231 1188

Heating Rise (oF) 44 46 47 48 50 52 53 55 57Heating Rise (oC) 24 25 26 27 28 29 30 31 32

High BlackCFM 1705 1643 1607 1568 1518 1483 1448 1404 1360

Heating Rise (oF) 40 41 42 43 45 46 47 48 50Heating Rise (oC) 22 23 24 24 25 25 26 27 28

PD(D,S)34809035 - 65oF

(19 - 36oC)

Low1 Blue

CFM 1402 1351 1311 1263 1224 1172 1136 1080 1041

Heating Rise (oF) 49 50 52 54 56 58 60 63 65

Heating Rise (oC) 27 28 29 30 31 32 33 35 36

Med-Low Pink

CFM 1457 1404 1367 1318 1284 1233 1197 1144 1104

Heating Rise (oF) 47 48 50 52 53 55 57 59 62

Heating Rise (oC) 26 27 28 29 29 31 32 33 34

Medium2 Red

CFM 1736 1695 1642 1601 1553 1512 1465 1427 1381

Heating Rise (oF) 39 40 41 42 44 45 46 48 49

Heating Rise (oC) 22 22 23 24 24 25 26 26 27

Med-High Orange

CFM 2149 2111 2062 2026 1980 1945 1905 1864 1793

Heating Rise (oF) NA NA NA NA NA 35 36 36 38

Heating Rise (oC) NA NA NA NA NA 19 20 20 21

High Black

CFM 2344 2306 2259 2203 2141 2070 1991 1902 1803

Heating Rise (oF) NA NA NA NA NA NA NA 36 38

Heating Rise (oC) NA NA NA NA NA NA NA 20 21

PD(D,S)34811530 - 60oF

(17 - 33oC)

Low Blue

CFM 1402 1351 1311 1263 1224 1172 1136 1080 1041

Heating Rise (oF) NA NA NA NA NA NA NA NA NA

Heating Rise (oC) NA NA NA NA NA NA NA NA NA

Med-Low Pink

CFM 1457 1404 1367 1318 1284 1233 1197 1144 1104

Heating Rise (oF) 60 NA NA NA NA NA NA NA NA

Heating Rise (oC) 33 NA NA NA NA NA NA NA NA

Medium2 Red

CFM 1736 1695 1642 1601 1553 1512 1465 1427 1381

Heating Rise (oF) 50 51 53 54 56 57 59 NA NA

Heating Rise (oC) 28 28 29 30 31 32 33 NA NA

Med-High1 Orange

CFM 2149 2111 2062 2026 1980 1945 1905 1864 1793

Heating Rise (oF) 40 41 42 43 44 45 46 47 48

Heating Rise (oC) 22 23 23 24 24 25 25 26 27

High Black

CFM 2344 2306 2259 2203 2141 2070 1991 1902 1803

Heating Rise (oF) 37 38 38 39 41 42 44 46 48

Heating Rise (oC) 21 21 21 22 23 23 24 25 27

PD(D,S)34813035 - 65oF

(19 - 36oC)

Low Blue

CFM 1402 1351 1311 1263 1224 1172 1136 1080 1041

Heating Rise (oF) NA NA NA NA NA NA NA NA NA

Heating Rise (oC) NA NA NA NA NA NA NA NA NA

Med-Low Pink

CFM 1457 1404 1367 1318 1284 1233 1197 1144 1104

Heating Rise (oF) NA NA NA NA NA NA NA NA NA

Heating Rise (oC) NA NA NA NA NA NA NA NA NA

Medium2 Red

CFM 1736 1695 1642 1601 1553 1512 1465 1427 1381

Heating Rise (oF) 55 57 59 60 62 64 NA NA NA

Heating Rise (oC) 31 32 33 33 34 35 NA NA NA

Med-High1 Orange

CFM 2149 2111 2062 2026 1980 1945 1905 1864 1793

Heating Rise (oF) 45 46 47 48 49 50 51 52 54

Heating Rise (oC) 25 25 26 26 27 28 28 29 30

High Black

CFM 2344 2306 2259 2203 2141 2070 1991 1902 1803

Heating Rise (oF) 41 42 43 44 45 47 48 51 53

Heating Rise (oC) 23 23 24 24 25 26 27 28 30

Page 8: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE8 516 11 2601 03

DRY COIL AIR DELIVERY* − HORIZONTAL AND DOWNFLOW DISCHARGE

UNITHeating Rise

RangeMotorSpeed

WireColor

EXTERNAL STATIC PRESSURE (in wc)0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9

PD(D,S)36009035 - 65oF

(19 - 36oC)

Low1 BlueCFM 1445 1389 1341 1281 1236 1189 1139 1072 1027

Heating Rise (oF) 47 49 51 53 55 57 60 63 NAHeating Rise (oC) 26 27 28 29 31 32 33 35 NA

Med-Low PinkCFM 1678 1635 1602 1558 1513 1474 1438 1404 1349

Heating Rise (oF) 41 42 42 44 45 46 47 48 50Heating Rise (oC) 23 23 24 24 25 26 26 27 28

Medium2 RedCFM 1927 1893 1858 1824 1791 1759 1720 1689 1640

Heating Rise (oF) 35 36 37 37 38 39 40 40 41Heating Rise (oC) 20 20 20 21 21 21 22 22 23

Med-High OrangeCFM 2131 2088 2065 2013 1982 1941 1888 1860 1785

Heating Rise (oF) NA NA NA NA NA 35 36 37 38Heating Rise (oC) NA NA NA NA NA 19 20 20 21

High BlackCFM 2461 2409 2339 2286 2192 2140 2062 1968 1874

Heating Rise (oF) NA NA NA NA NA NA NA 35 36Heating Rise (oC) NA NA NA NA NA NA NA 19 20

PD(D,S)36011530 - 60oF

(17 - 33oC)

Low BlueCFM 1445 1389 1341 1281 1236 1189 1139 1072 1027

Heating Rise (oF) 60 NA NA NA NA NA NA NA NAHeating Rise (oC) 33 NA NA NA NA NA NA NA NA

Med-Low PinkCFM 1678 1635 1602 1558 1513 1474 1438 1404 1349

Heating Rise (oF) 52 53 54 56 57 59 60 NA NAHeating Rise (oC) 29 30 30 31 32 33 34 NA NA

Medium2 RedCFM 1927 1893 1858 1824 1791 1759 1720 1689 1640

Heating Rise (oF) 45 46 47 48 49 49 51 51 53Heating Rise (oC) 25 26 26 26 27 27 28 29 29

Med-High1 OrangeCFM 2131 2088 2065 2013 1982 1941 1888 1860 1785

Heating Rise (oF) 41 42 42 43 44 45 46 47 49Heating Rise (oC) 23 23 23 24 24 25 26 26 27

High BlackCFM 2461 2409 2339 2286 2192 2140 2062 1968 1874

Heating Rise (oF) 35 36 37 38 40 41 42 44 46Heating Rise (oC) 20 20 21 21 22 23 23 25 26

PD(D,S)36013035 - 65oF

(19 - 36oC)

Low BlueCFM 1445 1389 1341 1281 1236 1189 1139 1072 1027

Heating Rise (oF) NA NA NA NA NA NA NA NA NAHeating Rise (oC) NA NA NA NA NA NA NA NA NA

Med-Low PinkCFM 1678 1635 1602 1558 1513 1474 1438 1404 1349

Heating Rise (oF) 57 59 60 62 64 65 NA NA NAHeating Rise (oC) 32 33 33 34 35 36 NA NA NA

Medium2 RedCFM 1927 1893 1858 1824 1791 1759 1720 1689 1640

Heating Rise (oF) 50 51 52 53 54 55 56 57 59Heating Rise (oC) 28 28 29 29 30 30 31 32 33

Med-High1 OrangeCFM 2131 2088 2065 2013 1982 1941 1888 1860 1785

Heating Rise (oF) 45 46 47 48 49 50 51 52 54Heating Rise (oC) 25 26 26 27 27 28 28 29 30

High BlackCFM 2461 2409 2339 2286 2192 2140 2062 1968 1874

Heating Rise (oF) 39 40 41 42 44 45 47 49 51Heating Rise (oC) 22 22 23 23 24 25 26 27 29

* Air delivery values are without air filter and are for dry coil (See PD(D,S)3 Wet Coil Pressure Drop table).1 Factory-shipped gas heating speed2 Factory-shipped cooling/heat pump heat speed

NA - Not allowed for heating speed

Note: For horizontal deduct field-supplied air filter pressure drop and wet coil pressure drop to obtain external static pressure available for ducting.For downflow applications see Wet Coil Air Delivery table for available static including wet coil, 1-in. (25 mm) filter and economizer.

Shaded areas indicate speed/static combinations that are not permitted for dehumidification speed.

DOWNFLOW WET COIL AIR DELIVERY (CFM) − HIGH SPEED WITH 1−IN. (25 MM) FILTER AND ECONOMIZER

UNIT SIZEEXTERNAL STATIC PRESSURE (in wc)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

36 1333 1289 1256 1214 1152 1118 1076 1035 997 95042 1612 1569 1527 1481 1451 1393 1351 1317 1278 124248 2166 2085 2002 1919 1798 1709 1582 1467 1270 98860 2298 2239 2180 2110 2044 1951 1862 1777 1697 1591

HORIZONTAL WET COIL PRESSURE DROPUnit Size

Standard CFM (S.C.F.M)500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000

30 0.12 0.15 0.19 0.23 0.27 36 0.07 0.11 0.18 0.26 0.35 42 0.04 0.07 0.1 0.15 0.21 48 0.11 0.14 0.17 0.22 0.28 60 0.1 0.17 0.23 0.31 0.36

HORIZONTAL ECONOMIZER 1 inch (25mm) FILTER PRESSURE DROP (in wc)UNIT PD(D,S)3 PRESSURE DROP

30−36 0.2042−60 0.25

Page 9: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 9516 11 2601 03

HORIZONTAL FILTER PRESSURE DROP TABLE (in wc)FILTER SIZE

in. (mm)CFM

500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 230020X24X1

(508X610x25) — — — .09 .10 .11 .13 .14 .15 .16 — — — — — — — — —

24X30X1(610X762x25) — — — 0.04 0.05 0.06 0.07 0.07 0.08 0.09 0.1 — — — — — — — —

24X36X1(610X914X25) — — — — — — — 0.06 0.07 0.07 0.08 0.09 0.09 0.10 0.11 0.12 0.13 0.14 0.14

NATURAL GAS ORIFICE SIZES AND MANIFOLD PRESSURE

Nameplate Input (Btu/hr) Orifice Size (Qty)

Manifold Press (in wc)

ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A.*0 to 2000(0-610 m)

2001 to 3000*(611 to 914 m)

3001 to 4000(915 to 1219 m)

4001 to 5000(1220 to 1524 m)

5001 to 6000(1524 to 1829 m)

40000Orifice No. (Qty) 44 (2) 45 (2)† 48 (2)† 48 (2)† 48 (2)†Manifold Press. (in wc) 3.2 3.2 3.8 3.5 3.2

60000Orifice No. (Qty) 38 (2) 41 (2)† 41 (2)† 42 (2)† 42 (2)†Manifold Press. (in wc) 3.6 3.8 3.4 3.4 3.2

90000Orifice No. (Qty) 38 (3) 41 (3)† 41 (3)† 42 (3)† 42 (3)†Manifold Press. (in wc) 3.6 3.8 3.4 3.4 3.2

115000Orifice No. (Qty) 33 (3) 36 (3)† 36 (3)† 36 (3)† 38 (3)†Manifold Press. (in wc) 3.8 3.8 3.6 3.3 3.6

130000Orifice No. (Qty) 31 (3) 31 (3) 33 (3)† 33 (3)† 34 (3)†Manifold Press. (in wc) 3.8 3.2 3.7 3.4 3.3

*In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above Sea level.In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft, use U.S.A. column 2001 to 3000 ft.Note: Orifice sizes and manifold pressure settings are based on natural gas with a heating value of 1025 Btu/ft3 and a specific gravity of .6.† Orifices available through your distributor.

PROPANE GAS ORIFICE SIZES AND MANIFOLD PRESSURE

Nameplate Input (Btu/hr) Orifice Size (Qty)

Manifold Press (in wc)

ALTITUDE OF INSTALLATION (FT. ABOVE SEA LEVEL) U.S.A.*0 to 2000(0-610 m)

2001 to 3000*(611 to 914 m)

3001 to 4000(915 to 1219 m)

4001 to 5000(1220 to 1524 m)

5001 to 6000(1524 to 1829 m)

40000Orifice No. (Qty) 55 (2) 56 (2) 56 (2) 56 (2) 56 (2)Manifold Press. (in wc) 10.0 11.0 11.0 11.0 10.7

60000Orifice No. (Qty) 53 (2) 54 (2) 54 (2) 54 (2) 54 (2)Manifold Press. (in wc) 10.0 11.0 11.0 11.0 11.0

90000Orifice No. (Qty) 53 (3) 54 (3) 54 (3) 54 (3) 54 (3)Manifold Press. (in wc) 10.0 11.0 11.0 11.0 11.0

115000Orifice No. (Qty) 51 (3) 52 (3) 52 (3) 53 (3) 53 (3)Manifold Press. (in wc) 10.0 11.0 10.6 11.0 11.0

130000Orifice No. (Qty) 49 (3) 50 (3) 51 (3) 52 (3) 52 (3)Manifold Press. (in wc) 10.0 11.0 11.0 11.0 11.0

*In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above Sea level.In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft (610-1372 m), use U.S.A. column 2001 to 3000 ft (611 to 914 m).†Use Kit No. NPLPCONV013A00 (0-2000 ft [0-610 m] above sea level). Use Kit No. NPLPCONV014A00 (2001-6000 ft [611-1829 m] above sea level).

HIGH ALTITUDE COMPENSATION, NATURAL GAS

NameplateInput (Btu/hr)

Rated Heating Input (Btu/hr), Natural Gas at Installation Altitude Above Sea Level, U.S.A.*0 to 2000 ft(0-610 m)

2001 to 3000 ft*(611 to 914 m)

3001 to 4000 ft(915 to 1219 m)

4001 to 5000 ft(1220 to 1524 m)

5001 to 6000 ft(1524 to 1829 m)

40000 40000 36000 34400 32800 3120060000 60000 54000 51600 49200 4680090000 90000 81000 77400 73800 70200115000 115000 103500 98900 94300 89700130000 130000 117000 111800 106600 101400

*In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above Sea level.In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft (610-1372 m), use U.S.A. column 2001 to 3000 ft (611 to 914 m).

HIGH ALTITUDE COMPENSATION, PROPANE GAS

Nameplate Input (Btu/hr)

Rated Heating Input (Btu/hr), LP Gas at Installation Altitude Above Sea Level, U.S.A.*

0 to 2000 ft(0-610 m)

2001 to 3000 ft*(611 to 914 m)

3001 to 4000 ft(915 to 1219 m)

4001 to 5000 ft(1220 to 1524 m)

5001 to 6000 ft(1524 to 1829 m)

40000 38000 31700 31700 31700 31200

60000 53000 45900 45900 45800 45800

90000 79000 68900 68900 68600 68600

115000 103000 100400 98900 83000 83000

130000 116000 115500 111800 101300 100400

*In the U.S.A., the input rating for altitudes above 2000 ft (610m) must be reduced by 4% for each 1000 ft (305 m) above Sea level.In Canada, the input rating for altitudes from 2001 to 4500 ft (611 to 1372 m) above sea level must be derated by 10% by an authorized gas conversion station or dealer. For Canadian Installations from 2000 to 4500 ft (610-1372 m), use U.S.A. column 2001 to 3000 ft (611 to 914 m).

Page 10: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE10 516 11 2601 03

PD

(D,S

)330

CO

OL

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

EVAP

ORA

TOR

AIR

COND

ENSE

R EN

TERI

NG A

IR T

EMPE

RATU

RES �

F (�

C)75

(23.

9)85

(29.

4)95

(35)

105

(40.

5)11

5 (4

6.1)

125

(51.

7)

CFM

/ BF

EWB

�F

(�C)

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

ns

875

/ 0.1

3

57 (1

3.9)

27.4

427

.44

2.00

26.4

026

.40

2.22

25.3

125

.31

2.47

24.1

324

.13

2.75

22.8

322

.83

3.07

21.4

221

.42

3.44

62 (1

6.7)

28.3

925

.49

2.00

27.0

924

.83

2.22

25.7

524

.11

2.47

24.3

423

.30

2.75

22.8

822

.88

3.07

21.4

521

.45

3.44

63* (

17.2

)28

.86

20.7

92.

0027

.53

20.1

72.

2226

.13

19.5

22.

4724

.63

18.8

42.

7523

.00

18.0

93.

0721

.25

17.2

93.

4467

(19.

4)31

.27

21.7

32.

0229

.83

21.1

02.

2428

.33

20.4

62.

4926

.73

19.7

72.

7625

.00

19.0

43.

0823

.14

18.2

43.

4572

(13.

9)34

.57

17.6

82.

0432

.97

17.1

02.

2631

.32

16.5

02.

5129

.56

15.8

72.

7927

.68

15.2

03.

1025

.66

14.4

43.

46

1000

/ 0.

17

57 (1

3.9)

28.7

828

.78

2.04

27.6

727

.67

2.26

26.4

926

.49

2.50

25.2

325

.23

2.78

23.8

423

.84

3.11

22.3

322

.33

3.47

62 (1

6.7)

29.2

527

.45

2.04

27.9

126

.71

2.26

26.5

526

.55

2.50

25.2

725

.27

2.79

23.8

823

.88

3.11

22.3

722

.37

3.47

63*(

17.2

)29

.64

22.2

42.

0428

.24

21.5

92.

2626

.76

20.9

22.

5125

.20

20.2

02.

7823

.51

19.4

23.

1021

.69

18.5

63.

4767

(19.

4)32

.09

23.2

92.

0530

.58

22.6

42.

2829

.00

21.9

62.

5227

.32

21.2

52.

8025

.54

20.4

83.

1223

.60

19.6

43.

4872

(13.

9)35

.47

18.7

42.

0833

.78

18.1

42.

3032

.02

17.5

22.

5530

.20

16.8

32.

8228

.25

16.1

13.

1426

.14

15.3

23.

49

1125

/ 0.

21

57 (1

3.9)

29.9

529

.95

2.07

28.7

528

.75

2.29

27.5

027

.50

2.54

26.1

526

.15

2.82

24.6

924

.69

3.14

23.1

023

.10

3.51

62 (1

6.7)

30.0

330

.03

2.07

28.8

128

.81

2.30

27.5

527

.55

2.54

26.2

026

.20

2.82

24.7

324

.73

3.14

23.1

423

.14

3.51

63* (

17.2

)30

.27

23.6

32.

0728

.80

22.9

62.

2927

.27

22.2

62.

5425

.65

21.5

02.

8223

.91

20.6

83.

1422

.05

19.7

73.

5067

(19.

4)32

.74

24.8

02.

0931

.17

24.1

12.

3129

.54

23.4

12.

5627

.80

22.6

72.

8325

.95

21.8

63.

1523

.97

20.9

63.

5172

(13.

9)36

.13

19.7

62.

1134

.40

19.1

02.

3432

.60

18.4

32.

5830

.70

17.7

32.

8628

.69

16.9

83.

1726

.51

16.1

73.

53

*A

t 75�F

(2

3.9

�C

) en

teri

ng

dry

bu

lb—

Ten

nessee V

alle

y A

uth

ori

ty [

TV

A]

ratin

g c

on

ditio

ns;

all

oth

ers

at

80�F

(2

6.7

�C

) en

teri

ng

dry

bu

lb.

See L

eg

en

d a

nd

No

tes.

PD

(D,S

)330

HE

AT

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

−10−6

0�F

(−2

3.3−

15.6�C

)

INDO

OR

AIR

OUT

DOO

R CO

IL E

NTER

ING

AIR

TEM

PERA

TURE

S �

F (�

C)-1

0 (-

23.3

)0

(-17

.8)

10 (-

12.2

)20

(-6.

7)30

(-1.

1)40

(4.4

)50

(10)

60 (1

5.6)

EDB

�F

(�C)

CFM

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

g

65

875

8.58

7.89

1.91

11.6

010

.67

1.98

14.8

313

.61

2.04

18.3

716

.66

2.12

22.3

519

.58

2.21

26.0

826

.08

2.29

30.2

930

.29

2.39

35.2

835

.28

2.52

1000

8.75

8.05

1.92

11.8

110

.87

1.99

15.0

713

.83

2.05

18.7

116

.97

2.11

22.6

019

.80

2.19

26.3

926

.39

2.26

30.7

030

.70

2.35

35.8

335

.83

2.47

1125

8.92

8.20

1.95

11.9

911

.04

2.00

15.2

814

.02

2.06

19.3

217

.52

2.12

22.8

119

.98

2.18

26.6

526

.65

2.24

31.0

431

.04

2.32

36.2

936

.29

2.43

70

875

8.06

7.42

1.98

11.1

210

.23

2.06

14.3

713

.19

2.13

17.9

016

.23

2.21

22.0

719

.33

2.31

25.7

425

.74

2.40

29.8

729

.87

2.50

34.7

334

.73

2.64

1000

8.24

7.58

2.00

11.3

310

.42

2.07

14.6

213

.42

2.14

18.1

916

.49

2.20

22.3

019

.54

2.29

26.0

326

.03

2.36

30.2

730

.27

2.46

35.2

735

.27

2.58

1125

8.40

7.73

2.02

11.5

110

.59

2.09

14.8

313

.61

2.15

18.4

316

.71

2.21

22.5

119

.72

2.28

26.2

926

.29

2.35

30.5

730

.57

2.43

35.7

035

.70

2.54

75

875

7.50

6.90

2.06

10.6

09.

762.

1513

.88

12.7

42.

2217

.41

15.7

92.

3121

.72

19.0

32.

4225

.38

25.3

82.

5129

.46

29.4

62.

6234

.18

34.1

82.

7510

007.

687.

062.

0810

.81

9.95

2.16

14.1

312

.97

2.23

17.6

916

.05

2.30

21.9

919

.27

2.40

25.6

825

.68

2.48

29.8

329

.83

2.57

34.7

034

.70

2.69

1125

7.84

7.21

2.11

11.0

010

.12

2.18

14.3

413

.16

2.24

17.9

416

.27

2.30

22.2

119

.46

2.39

25.9

325

.93

2.46

30.1

330

.13

2.54

35.1

435

.14

2.66

See

Leg

end

and

Not

es fo

llow

ing

tabl

es.

Page 11: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE516 11 2601 03 11

PD

(D,S

)336

CO

OL

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

EVAP

ORA

TOR

AIR

COND

ENSE

R EN

TERI

NG A

IR T

EMPE

RATU

RES �

F (�

C)75

(23.

9)85

(29.

4)95

(35)

105

(40.

5)11

5 (4

6.1)

125

(51.

7)

CFM

/ BF

EWB

�F

(�C)

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

ns

1050

/ 0.

12

57 (1

3.9)

33.5

933

.59

2.41

32.2

532

.25

2.67

30.8

230

.82

2.96

29.2

429

.24

3.28

27.5

027

.50

3.66

25.5

825

.58

4.08

62 (1

6.7)

34.7

730

.70

2.42

33.1

029

.87

2.67

31.3

328

.94

2.96

29.4

627

.90

3.29

27.5

627

.56

3.66

25.6

225

.62

4.08

63* (

17.2

)35

.34

25.0

12.

4233

.64

24.2

32.

6831

.81

23.4

02.

9629

.83

22.5

23.

2927

.67

21.5

53.

6625

.33

20.5

04.

0867

(19.

4)38

.13

26.0

62.

4436

.31

25.2

82.

7034

.33

24.4

62.

9932

.20

23.5

73.

3129

.86

22.5

93.

6827

.36

21.5

44.

1072

(13.

9)41

.96

21.0

42.

4739

.94

20.3

12.

7437

.75

19.5

43.

0335

.39

18.7

03.

3532

.82

17.8

13.

7130

.05

16.8

54.

12

1200

/ 0.

18

57 (1

3.9)

35.1

135

.11

2.47

33.6

933

.69

2.73

32.1

432

.14

3.02

30.4

530

.45

3.34

28.5

728

.57

3.71

26.4

926

.49

4.14

62 (1

6.7)

35.7

133

.01

2.47

33.9

732

.07

2.73

32.2

032

.20

3.02

30.5

030

.50

3.34

28.6

128

.61

3.71

26.5

326

.53

4.14

63* (

17.2

)36

.21

26.6

92.

4734

.40

25.8

92.

7332

.47

25.0

33.

0230

.40

24.1

03.

3428

.14

23.0

93.

7125

.72

21.9

74.

1367

(19.

4)38

.99

27.8

62.

5037

.07

27.0

62.

7635

.00

26.2

03.

0432

.76

25.2

73.

3730

.32

24.2

53.

7327

.71

23.1

44.

1572

(13.

9)42

.86

22.2

32.

5340

.74

21.4

82.

7938

.42

20.6

83.

0835

.93

19.8

23.

4033

.26

18.8

53.

7630

.40

17.8

24.

17

1350

/ 0.

24

57 (1

3.9)

36.4

136

.41

2.52

34.8

934

.89

2.78

33.2

333

.23

3.07

31.4

231

.42

3.40

29.4

129

.41

3.77

27.2

227

.22

4.19

62 (1

6.7)

36.5

436

.49

2.53

34.9

534

.95

2.79

33.2

833

.28

3.07

31.4

731

.47

3.40

29.4

529

.45

3.77

27.2

527

.25

4.19

63* (

17.2

)36

.85

28.2

92.

5334

.96

27.4

62.

7832

.97

26.5

83.

0730

.82

25.6

13.

3928

.48

24.5

33.

7626

.00

23.3

44.

1867

(19.

4)39

.63

29.5

92.

5537

.64

28.7

52.

8135

.49

27.8

63.

1033

.16

26.8

93.

4230

.65

25.8

23.

7827

.98

24.6

34.

2072

(13.

9)43

.50

23.3

62.

5841

.27

22.5

92.

8538

.89

21.7

43.

1336

.32

20.8

13.

4533

.56

19.8

23.

8230

.62

18.7

64.

22

*A

t 75�F

(2

3.9

�C

) en

teri

ng

dry

bu

lb—

Ten

nessee V

alle

y A

uth

ori

ty [

TV

A]

ratin

g c

on

ditio

ns;

all

oth

ers

at

80�F

(2

6.7

�C

) en

teri

ng

dry

bu

lb.

See L

eg

en

d a

nd

No

tes.

PD

(D,S

)336

HE

AT

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

−10−6

0�F

(−2

3.3−

15.6�C

)

INDO

OR

AIR

OUT

DOO

R CO

IL E

NTER

ING

AIR

TEM

PERA

TURE

S �

F (�

C)-1

0 (-

23.3

)0

(-17

.8)

10 (-

12.2

)20

(-6.

7)30

(-1.

1)40

(4.4

)50

(10)

60 (1

5.6)

EDB

�F

(�C)

CFM

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

g

65

1050

12.1

511

.18

2.30

15.3

114

.08

2.39

19.1

917

.61

2.49

22.6

820

.57

2.58

26.6

823

.38

2.68

31.2

831

.28

2.80

36.7

036

.70

2.96

42.9

942

.99

3.16

1200

12.3

811

.39

2.32

15.5

714

.32

2.40

19.4

117

.82

2.50

22.9

620

.82

2.58

27.0

123

.66

2.67

31.6

831

.68

2.78

37.2

037

.20

2.94

43.0

643

.06

3.12

1350

12.5

911

.58

2.35

15.7

914

.53

2.43

19.6

218

.01

2.52

23.1

921

.03

2.59

27.2

923

.91

2.67

32.0

132

.01

2.78

37.5

137

.51

2.93

42.8

242

.82

3.10

70

1050

11.7

110

.77

2.41

14.8

813

.69

2.50

18.7

617

.22

2.61

22.3

920

.31

2.70

26.3

223

.06

2.80

30.8

130

.81

2.93

36.1

436

.14

3.09

42.4

242

.42

3.31

1200

11.9

410

.99

2.44

15.1

313

.93

2.52

19.1

317

.55

2.62

22.6

520

.54

2.70

26.6

323

.34

2.79

31.2

131

.21

2.91

36.6

236

.62

3.06

42.6

242

.62

3.25

1350

12.1

511

.18

2.47

15.3

714

.14

2.54

19.3

517

.76

2.64

22.8

820

.75

2.71

26.9

123

.58

2.80

31.5

431

.54

2.91

37.0

037

.00

3.06

42.4

942

.49

3.24

75

1050

11.2

310

.33

2.53

14.4

213

.27

2.62

18.0

116

.53

2.72

22.0

920

.03

2.84

25.9

622

.75

2.94

30.3

630

.36

3.06

35.5

835

.58

3.23

41.7

741

.77

3.46

1200

11.4

610

.55

2.56

14.6

813

.51

2.64

18.3

116

.81

2.73

22.3

620

.27

2.83

26.2

723

.02

2.92

30.7

430

.74

3.04

36.0

436

.04

3.19

42.1

542

.15

3.40

1350

11.6

710

.74

2.59

14.9

113

.72

2.67

18.6

117

.08

2.75

22.5

920

.48

2.84

26.5

323

.24

2.93

31.0

731

.07

3.03

36.4

336

.43

3.19

42.1

142

.11

3.38

See

Leg

end

and

Not

es fo

llow

ing

tabl

es.

Page 12: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE12 516 11 2601 03

PD

(D,S

)342

CO

OL

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

EVAP

ORA

TOR

AIR

COND

ENSE

R EN

TERI

NG A

IR T

EMPE

RATU

RES �

F (�

C)75

(23.

9)85

(29.

4)95

(35)

105

(40.

5)11

5 (4

6.1)

125

(51.

7)

CFM

/ BF

EWB

�F

(�C)

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

ns

1225

/ 0.

14

57 (1

3.9)

38.2

938

.29

2.70

36.7

836

.78

3.00

35.1

735

.17

3.35

33.4

333

.43

3.76

31.5

531

.55

4.23

29.5

329

.53

4.78

62 (1

6.7)

39.6

035

.26

2.71

37.7

434

.27

3.01

35.7

933

.19

3.36

33.7

432

.00

3.76

31.6

231

.62

4.24

29.5

829

.58

4.78

63* (

17.2

)40

.17

28.7

02.

7238

.23

27.8

03.

0236

.20

26.8

43.

3734

.04

25.8

13.

7731

.75

24.7

34.

2429

.30

23.5

74.

7767

(19.

4)43

.43

29.9

92.

7641

.34

29.0

73.

0739

.13

28.1

03.

4236

.80

27.0

73.

8334

.33

25.9

84.

3031

.69

24.8

24.

8572

(13.

9)47

.71

24.5

22.

8345

.36

23.6

43.

1442

.91

22.6

93.

5040

.34

21.7

03.

9137

.63

20.6

54.

4034

.75

19.5

44.

95

1400

/ 0.

17

57 (1

3.9)

40.1

140

.11

2.76

38.4

838

.48

3.06

36.7

336

.73

3.42

34.8

534

.85

3.83

32.8

332

.83

4.31

30.6

530

.65

4.86

62 (1

6.7)

40.7

737

.93

2.77

38.8

336

.81

3.07

36.8

236

.82

3.42

34.9

134

.91

3.83

32.8

832

.88

4.31

30.6

930

.69

4.86

63* (

17.2

)41

.23

30.6

52.

7739

.19

29.7

03.

0737

.04

28.7

03.

4234

.77

27.6

33.

8332

.38

26.4

84.

2929

.83

25.2

54.

8367

(19.

4)44

.54

32.0

92.

8242

.33

31.1

23.

1240

.00

30.1

03.

4837

.55

29.0

23.

8934

.97

27.8

94.

3732

.23

26.6

44.

9172

(13.

9)48

.87

25.8

72.

8946

.39

24.9

23.

2043

.82

23.9

33.

5641

.13

22.8

93.

9838

.30

21.8

04.

4635

.30

20.6

45.

02

1575

/ 0.

19

57 (1

3.9)

41.6

741

.67

2.82

39.9

239

.92

3.13

38.0

438

.04

3.48

36.0

436

.04

3.90

33.8

933

.89

4.38

31.5

731

.57

4.93

62 (1

6.7)

41.7

841

.78

2.82

40.0

040

.00

3.13

38.1

038

.10

3.49

36.0

936

.09

3.90

33.9

433

.94

4.38

31.6

131

.61

4.94

63* (

17.2

)42

.07

32.5

32.

8339

.93

31.5

33.

1337

.70

30.4

83.

4835

.35

29.3

53.

8832

.87

28.1

34.

3530

.26

26.8

14.

8967

(19.

4)45

.42

34.1

12.

8743

.10

33.1

13.

1840

.66

32.0

43.

5338

.14

30.8

93.

9535

.47

29.6

84.

4332

.65

28.3

64.

9772

(13.

9)49

.79

27.1

22.

9547

.20

26.1

43.

2644

.53

25.1

13.

6241

.74

24.0

34.

0438

.81

22.9

04.

5335

.71

21.7

05.

08

*A

t 75�F

(2

3.9

�C

) en

teri

ng

dry

bu

lb—

Ten

nessee V

alle

y A

uth

ori

ty [

TV

A]

ratin

g c

on

ditio

ns;

all

oth

ers

at

80�F

(2

6.7

�C

) en

teri

ng

dry

bu

lb.

See L

eg

en

d a

nd

No

tes.

PD

(D,S

)342

HE

AT

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

−10−6

0�F

(−2

3.3−

15.6�C

)

INDO

OR

AIR

OUT

DOO

R CO

IL E

NTER

ING

AIR

TEM

PERA

TURE

S �

F (�

C)-1

0 (-

23.3

)0

(-17

.8)

10 (-

12.2

)20

(-6.

7)30

(-1.

1)40

(4.4

)50

(10)

60 (1

5.6)

EDB

�F

(�C)

CFM

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

g

65

1225

13.5

412

.46

2.47

17.4

716

.08

2.63

21.9

620

.15

2.78

25.9

823

.56

2.88

30.5

426

.76

2.98

35.7

835

.78

3.11

42.0

142

.01

3.30

48.7

748

.77

3.53

1400

13.7

212

.62

2.48

17.6

816

.26

2.64

22.1

420

.32

2.77

26.2

123

.77

2.86

30.8

527

.03

2.95

36.1

836

.18

3.07

42.4

342

.43

3.24

48.1

548

.15

3.46

1575

13.8

812

.77

2.50

17.8

516

.43

2.65

22.3

020

.47

2.78

26.4

123

.95

2.86

31.1

027

.25

2.95

36.5

036

.50

3.07

42.1

242

.12

3.22

47.1

947

.19

3.42

70

1225

13.2

112

.15

2.61

17.1

115

.75

2.77

21.7

419

.96

2.92

25.7

023

.30

3.02

30.1

526

.42

3.12

35.2

735

.27

3.25

41.3

741

.37

3.44

48.3

248

.32

3.70

1400

13.4

012

.33

2.62

17.3

315

.95

2.78

21.9

420

.14

2.91

25.9

323

.52

3.00

30.4

526

.68

3.10

35.6

735

.67

3.22

41.8

641

.86

3.40

47.8

447

.84

3.62

1575

13.5

712

.48

2.64

17.5

216

.12

2.79

22.1

320

.31

2.92

26.1

423

.71

3.00

30.7

226

.91

3.09

35.9

735

.97

3.21

41.8

441

.84

3.37

47.0

347

.03

3.59

75

1225

12.7

911

.77

2.75

16.7

015

.37

2.91

21.0

319

.31

3.05

25.4

123

.05

3.17

29.7

626

.07

3.27

34.7

634

.76

3.41

40.7

540

.75

3.61

47.8

047

.80

3.89

1400

12.9

911

.95

2.76

16.9

315

.58

2.92

21.5

919

.82

3.05

25.6

423

.25

3.15

30.0

626

.34

3.24

35.1

535

.15

3.37

41.2

441

.24

3.56

47.4

947

.49

3.80

1575

13.1

712

.12

2.79

17.1

315

.76

2.93

21.8

620

.07

3.06

25.8

523

.44

3.15

30.3

126

.56

3.23

35.4

635

.46

3.35

41.4

841

.48

3.53

46.7

946

.79

3.76

See

Leg

end

and

Not

es fo

llow

ing

tabl

es.

Page 13: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE516 11 2601 03 13

PD

(D,S

)348

CO

OL

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

EVAP

ORA

TOR

AIR

COND

ENSE

R EN

TERI

NG A

IR T

EMPE

RATU

RES �

F (�

C)75

(23.

9)85

(29.

4)95

(35)

105

(40.

5)11

5 (4

6.1)

125

(51.

7)

CFM

/ BF

EWB

�F

(�C)

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

ns

1400

/ 0.

15

57 (1

3.9)

45.5

645

.56

3.20

43.6

443

.64

3.58

41.6

241

.62

3.98

39.4

739

.47

4.41

37.1

537

.15

4.90

34.6

434

.64

5.46

62 (1

6.7)

47.1

241

.32

3.21

44.7

540

.06

3.59

42.3

338

.74

3.99

39.8

137

.27

4.42

37.2

337

.23

4.91

34.6

934

.69

5.46

63* (

17.2

)47

.82

33.6

63.

2145

.36

32.5

23.

5942

.84

31.3

43.

9940

.19

30.1

14.

4237

.38

28.8

14.

9134

.39

27.4

15.

4667

(19.

4)51

.57

35.1

03.

2248

.88

33.9

33.

6246

.13

32.7

44.

0243

.25

31.4

94.

4640

.21

30.1

74.

9536

.94

28.7

55.

4972

(13.

9)56

.55

28.5

73.

2353

.52

27.5

03.

6450

.45

26.3

44.

0647

.26

25.1

24.

5143

.85

23.8

34.

9940

.27

22.4

85.

53

1600

/ 0.

18

57 (1

3.9)

47.6

047

.60

3.26

45.5

045

.50

3.65

43.3

143

.31

4.05

40.9

840

.98

4.49

38.4

838

.48

4.98

35.7

635

.76

5.53

62 (1

6.7)

48.4

044

.34

3.26

45.9

142

.93

3.65

43.4

143

.41

4.05

41.0

441

.04

4.49

38.5

338

.53

4.98

35.8

135

.81

5.53

63* (

17.2

)48

.97

35.8

73.

2746

.36

34.6

73.

6543

.69

33.4

44.

0540

.92

32.1

54.

4937

.98

30.7

64.

9734

.88

29.2

75.

5267

(19.

4)52

.75

37.4

93.

2749

.90

36.2

63.

6847

.00

35.0

04.

0943

.98

33.6

94.

5240

.79

32.2

85.

0137

.41

30.7

75.

5572

(13.

9)57

.75

30.1

43.

2854

.58

28.9

33.

7051

.36

27.7

14.

1348

.01

26.4

44.

5744

.45

25.0

95.

0640

.74

23.6

95.

59

1800

/ 0.

21

57 (1

3.9)

49.3

249

.32

3.32

47.0

647

.06

3.71

44.7

144

.71

4.12

42.2

342

.23

4.56

39.5

539

.55

5.05

36.6

536

.65

5.59

62 (1

6.7)

49.5

549

.16

3.32

47.1

447

.14

3.71

44.7

744

.77

4.12

42.2

842

.28

4.56

39.6

039

.60

5.05

36.7

036

.70

5.59

63* (

17.2

)49

.85

38.0

03.

3247

.12

36.7

43.

7144

.35

35.4

44.

1141

.47

34.0

74.

5538

.44

32.6

05.

0335

.24

30.9

85.

5767

(19.

4)53

.64

39.7

83.

3250

.67

38.4

93.

7347

.66

37.1

74.

1544

.52

35.7

84.

5941

.22

34.2

85.

0737

.75

32.6

55.

6072

(13.

9)58

.69

31.5

33.

3355

.39

30.2

93.

7652

.04

29.0

24.

1848

.54

27.7

04.

6344

.88

26.3

15.

1241

.06

24.8

55.

65

*A

t 75�F

(2

3.9

�C

) en

teri

ng

dry

bu

lb—

Ten

nessee V

alle

y A

uth

ori

ty [

TV

A]

ratin

g c

on

ditio

ns;

all

oth

ers

at

80�F

(2

6.7

�C

) en

teri

ng

dry

bu

lb.

See L

eg

en

d a

nd

No

tes.

PD

(D,S

)348

HE

AT

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

−10−6

0�F

(−2

3.3−

15.6�C

)

INDO

OR

AIR

OUT

DOO

R CO

IL E

NTER

ING

AIR

TEM

PERA

TURE

S �

F (�

C)-1

0 (-

23.3

)0

(-17

.8)

10 (-

12.2

)20

(-6.

7)30

(-1.

1)40

(4.4

)50

(10)

60 (1

5.6)

EDB

�F

(�C)

CFM

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

g

65(1

8.3)

1400

15.7

614

.50

2.95

20.3

618

.74

3.07

25.2

223

.15

3.20

31.0

528

.16

3.36

36.2

231

.73

3.50

41.9

441

.94

3.65

48.5

548

.55

3.83

56.4

156

.41

4.05

1600

16.0

114

.73

2.98

20.6

418

.99

3.09

25.5

523

.46

3.21

31.3

628

.44

3.35

36.5

932

.06

3.48

42.4

242

.42

3.61

49.1

749

.17

3.77

57.1

257

.12

3.95

1800

16.2

414

.94

3.02

20.9

019

.23

3.12

25.8

523

.73

3.23

31.6

328

.69

3.37

36.9

232

.35

3.48

42.8

442

.84

3.60

49.7

249

.72

3.74

57.4

857

.48

3.90

70(2

1.1)

1400

15.2

614

.04

3.08

19.8

518

.27

3.20

24.6

822

.65

3.33

30.1

327

.32

3.48

35.8

031

.37

3.65

41.4

041

.40

3.81

47.8

747

.87

4.00

55.5

855

.58

4.24

1600

15.5

214

.28

3.11

20.1

418

.53

3.22

25.0

422

.98

3.34

30.9

928

.11

3.50

36.1

631

.68

3.63

41.8

741

.87

3.78

48.4

848

.48

3.94

56.3

856

.38

4.15

1800

15.7

614

.50

3.15

20.4

118

.78

3.25

25.3

323

.25

3.36

31.2

828

.37

3.51

36.4

931

.97

3.63

42.2

842

.28

3.76

49.0

149

.01

3.91

56.8

256

.82

4.09

75(2

3.9)

1400

14.6

813

.51

3.22

19.2

917

.74

3.34

24.1

222

.14

3.47

29.3

426

.61

3.63

35.3

831

.00

3.82

40.8

540

.85

3.98

47.2

147

.21

4.18

54.7

754

.77

4.43

1600

14.9

513

.76

3.25

19.5

918

.03

3.36

24.4

722

.46

3.48

29.7

626

.99

3.62

35.7

331

.31

3.79

41.3

141

.31

3.94

47.8

047

.80

4.12

55.5

655

.56

4.35

1800

15.1

913

.98

3.29

19.8

518

.27

3.39

24.7

822

.74

3.51

30.1

927

.38

3.63

36.0

731

.60

3.79

41.7

241

.72

3.93

48.3

048

.30

4.09

56.1

256

.12

4.28

See

Leg

end

and

Not

es fo

llow

ing

tabl

es.

Page 14: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE14 516 11 2601 03

PD

(D,S

)360

CO

OL

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

EVAP

ORA

TOR

AIR

COND

ENSE

R EN

TERI

NG A

IR T

EMPE

RATU

RES �

F (�

C)75

(23.

9)85

(29.

4)95

(35)

105

(40.

5)11

5 (4

6.1)

125

(51.

7)

CFM

/ BF

EWB

�F

(�C)

Capa

city

MBt

uhTo

tal

Sys

KWCa

paci

ty M

Btuh

Tota

lSy

s KW

Capa

city

MBt

uhTo

tal

Sys

KWCa

paci

ty M

Btuh

Tota

lSy

s KW

Capa

city

MBt

uhTo

tal

Sys

KWCa

paci

ty M

Btuh

Tota

lSy

s KW

Tota

lSe

nsTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

Tota

lSe

nsTo

tal

Sens

1750

/ 0.

19

57 (1

3.9)

56.4

256

.42

3.97

54.0

954

.09

4.39

51.6

051

.60

4.86

48.8

948

.89

5.40

45.8

745

.87

6.01

42.6

042

.60

6.70

62 (1

6.7)

58.0

051

.82

3.99

55.1

550

.34

4.40

52.1

948

.67

4.87

49.1

048

.72

5.40

45.9

445

.94

6.01

42.6

642

.66

6.70

63* (

17.2

)58

.78

42.0

54.

0055

.87

40.6

94.

4152

.77

39.2

54.

8849

.45

37.7

25.

4145

.84

36.0

66.

0142

.01

34.2

66.

6967

(19.

4)63

.34

43.8

64.

0560

.17

42.4

84.

4756

.78

41.0

24.

9453

.14

39.4

55.

4649

.23

37.7

76.

0645

.09

35.9

66.

7472

(13.

9)69

.39

35.4

24.

1365

.81

34.1

54.

5562

.02

32.7

25.

0257

.99

31.1

95.

5453

.69

29.5

66.

1349

.14

27.8

56.

80

1850

/ 0.

20

57 (1

3.9)

56.9

456

.94

3.99

54.5

754

.57

4.41

52.0

352

.03

4.88

49.2

749

.27

5.42

46.2

346

.23

6.03

42.8

842

.88

6.72

62 (1

6.7)

58.3

352

.61

4.01

55.4

451

.08

4.42

52.4

749

.35

4.89

49.3

649

.36

5.42

46.3

046

.30

6.03

42.9

442

.94

6.72

63* (

17.2

)59

.07

42.6

24.

0256

.12

41.2

44.

4353

.00

39.8

04.

9049

.63

38.2

55.

4245

.98

36.5

66.

0342

.13

34.7

46.

7167

(19.

4)63

.63

44.4

74.

0860

.42

43.0

84.

4957

.00

41.6

04.

9653

.31

40.0

25.

4849

.37

38.3

16.

0845

.20

36.4

86.

7572

(13.

9)69

.68

35.8

34.

1566

.07

34.5

14.

5762

.25

33.0

75.

0458

.17

31.5

25.

5653

.84

29.8

86.

1549

.25

28.1

66.

82

2250

/ 0.

27

57 (1

3.9)

60.8

760

.87

4.19

58.1

458

.14

4.61

55.2

355

.23

5.08

52.0

552

.05

5.62

48.6

148

.61

6.22

44.8

844

.88

6.90

62 (1

6.7)

60.9

560

.95

4.19

58.2

358

.23

4.61

55.3

155

.31

5.08

52.1

252

.12

5.62

48.6

748

.67

6.22

44.9

344

.93

6.90

63* (

17.2

)61

.07

47.5

04.

1957

.83

46.0

14.

6154

.45

44.4

35.

0750

.81

42.6

95.

6046

.95

40.7

96.

1942

.89

38.6

96.

8767

(19.

4)65

.61

49.7

44.

2562

.14

48.2

34.

6758

.42

46.6

05.

1354

.47

44.8

45.

6650

.28

42.9

36.

2545

.90

40.8

26.

9272

(13.

9)71

.73

39.0

74.

3367

.82

37.6

04.

7563

.70

36.0

55.

2159

.34

34.4

15.

7454

.72

32.6

76.

3249

.88

30.8

36.

98

*A

t 75�F

(2

3.9

�C

) en

teri

ng

dry

bu

lb—

Ten

nessee V

alle

y A

uth

ori

ty [

TV

A]

ratin

g c

on

ditio

ns;

all

oth

ers

at

80�F

(2

6.7

�C

) en

teri

ng

dry

bu

lb.

See L

eg

en

d a

nd

No

tes.

PD

(D,S

)360

HE

AT

ING

EX

TE

ND

ED

PE

RF

OR

MA

NC

E T

AB

LE

−10−6

0�F

(−2

3.3−

15.6�C

)

INDO

OR

AIR

OUT

DOO

R CO

IL E

NTER

ING

AIR

TEM

PERA

TURE

S �

F (�

C)-1

0 (-

23.3

)0

(-17

.8)

10 (-

12.2

)20

(-6.

7)30

(-1.

1)40

(4.4

)50

(10)

60 (1

5.6)

EDB

�F

(�C)

CFM

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KW

Capa

city

MBt

uhTo

tal

Sys

KWTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

gTo

tal

Inte

g

65

1750

19.2

617

.72

3.62

24.8

822

.89

3.77

30.7

928

.26

3.91

37.2

033

.74

4.06

44.9

839

.41

4.26

51.9

651

.96

4.43

60.0

260

.02

4.64

69.6

269

.62

4.91

1800

19.3

417

.79

3.63

24.9

822

.98

3.78

30.9

028

.37

3.92

37.3

333

.85

4.07

45.0

939

.50

4.26

52.0

952

.09

4.42

60.1

960

.19

4.62

69.8

469

.84

4.89

2250

20.0

618

.45

3.75

25.7

423

.69

3.88

31.7

529

.14

4.00

38.3

134

.75

4.12

45.9

340

.25

4.28

53.1

253

.12

4.41

61.4

861

.48

4.58

71.5

171

.51

4.81

70

1750

18.3

716

.90

3.77

24.0

122

.09

3.92

30.0

027

.54

4.08

36.3

632

.98

4.24

44.4

738

.96

4.46

51.3

251

.32

4.63

59.2

259

.22

4.85

68.6

368

.63

5.12

1800

18.4

516

.97

3.78

24.1

122

.18

3.93

30.1

127

.64

4.09

36.4

933

.09

4.24

44.5

839

.06

4.45

51.4

351

.43

4.63

59.3

959

.39

4.83

68.8

568

.85

5.10

2250

19.1

517

.62

3.90

24.9

222

.93

4.04

30.9

628

.41

4.17

37.4

433

.95

4.30

45.4

239

.80

4.47

52.4

552

.45

4.61

60.6

560

.65

4.79

70.4

770

.47

5.02

7517

5017

.44

16.0

43.

9323

.12

21.2

74.

0929

.18

26.7

84.

2635

.57

32.2

64.

4343

.08

37.7

44.

6350

.66

50.6

64.

8558

.44

58.4

45.

0767

.67

67.6

75.

3518

0017

.52

16.1

23.

9423

.22

21.3

64.

1029

.28

26.8

84.

2735

.70

32.3

74.

4343

.34

37.9

74.

6450

.78

50.7

84.

8458

.60

58.6

05.

0567

.87

67.8

75.

3322

5018

.19

16.7

34.

0623

.99

22.0

74.

2130

.13

27.6

54.

3536

.62

33.2

14.

4844

.87

39.3

14.

6851

.79

51.7

94.

8259

.83

59.8

35.

0069

.45

69.4

55.

24L

EG

EN

Ded

b—

En

teri

ng

Dry

-B

ulb

Ew

b

— E

nte

rin

g W

et-

Bu

lbkW

To

tal U

nit P

ow

er

Inp

ut

SH

C

— S

en

sib

le H

eat

Cap

acity (

10

00

Btu

h)

TC

To

tal C

ap

acity (

10

00

Btu

h)

(net)

CO

OL

ING

NO

TE

S:

1.

Ratin

gs a

re n

et;

th

ey a

cco

un

t fo

r th

e e

ffects

of th

e e

vap

ora

tor-

fan

mo

tor

po

wer

an

d h

eat.

2. D

irect

inte

rpo

latio

n is p

erm

issib

le. D

o n

ot

ext

rap

ola

te.

3.

Th

e f

ollo

win

g f

orm

ula

s m

ay b

e u

sed

:

4. T

he S

HC

is b

ased

on

80�F

(2

6.7

�C

) ed

b t

em

pera

ture

of air

en

teri

ng

evap

ora

tor

co

il. B

elo

w 8

0�F

(2

6.7�C

) ed

b,

su

btr

act

(co

rr facto

r x

cfm

) fr

om

SH

C.

Ab

ove 8

0�F

(2

6.7�C

) ed

b,

ad

d (

co

rr facto

r x

cfm

) to

SH

C.

Co

rrectio

n F

acto

r =

1.1

0 x

(1

+ B

F)

x (e

db

+ 8

0).

5. In

teg

rate

d c

ap

acity is m

axi

mu

m (

insta

nta

neo

us)

cap

acity less t

he e

ffect

of fr

ost

on

th

e o

utd

oo

r co

il an

d t

he

heat

req

uir

ed

to

defr

ost

it.

Sen

sib

le c

ap

acity (

Btu

h)

1.1

0 x

cfm

t ldb

= t

ed

b -

Wet-

bu

lb t

em

pera

ture

co

rresp

on

din

g t

o e

nth

alp

y

air

leavin

g e

vap

ora

tor

co

il (h

lwb

)t lw

b =

tota

l cap

acity (

Btu

h)

4.5

x c

fm

hlw

b =

hew

b -

Wh

ere

: hew

b =

En

thalp

y o

f air

en

teri

ng

evap

ora

tor

co

il

Page 15: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 15516 11 2601 03

UNIT DIMENSIONS, PD(D,S)330 − 36

PD

D3

30 36

PD

D3

30 36

Page 16: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE16 516 11 2601 03

UNIT DIMENSIONS, PD(D,S)3 42 − 60

PD

D3

42 48 60

PD

D3

42 48 60

Page 17: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 17516 11 2601 03

TYPICAL PIPING AND WIRING

ROOF

RETURN−AIRFLEXIBLE DUCT

CEILING

CONCENTRIC DIFFUSER BOX(FIELD−SUPPLIED)

SUPPLY−AIRFLEXIBLE DUCT

ROOF−MOUNTINGCURB

INDOORTHERMOSTAT

DISCONNECTPER NEC*

FROMPOWERSOURCE

RETURNAIR

TOP COVER

FROMGAS LINE

*NEC − NATIONAL ELECTRICAL CODE

Page 18: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE18 516 11 2601 03

BALANCE POINT WORKSHEET

0

10

20

30

40

50

60

70

-20-10����� �0����� �10����� 20����� 30����� 40����� 50����� 60����� 70

OUTDOOR TEMPERATURE, ºF

BU

ILD

ING

HE

AT

LO

SS

, UN

IT IN

TE

GR

AT

ED

HE

AT

ING

CA

PA

CIT

Y, M

BT

UH

60

BASED ON INDOOR ENT. AIR AT

70 ºF AND AT RATED CFM

48

42

36

30

24

Page 19: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 19516 11 2601 03

CONNECTION WIRING SCHEMATIC − 208/230−3−60

BK

Y

BR

BK

Y

BR

BK

W

BR

O

FIELD

SUPPLY

C F

SCHEMATIC208/230−3−60

1

1

LEGEND

FIELD SPLICETERMINAL (MARKED)TERMINAL (UNMARKED)SPLICE (IF USED)SPLICE (MARKED)FACTORY WIRINGFIELD CONTROL WIRINGFIELD POWER WIRINGACCESSORY OR OPTIONALWIRING

C CONTACTOR

COMP COMPRESSOR MOTORCR COMBUSTION RELAY

EQUIP EQUIPMENTFS FLAME SENSORGND GROUND

I IGNITORIGC INTERGRATED GAS UNIT CONTROLLER

IDM INDUCED DRAFT MOTORIFM INDOOR FAN MOTOR

LS1 PRIMARY LIMIT SWITCH

MGV MAIN GAS VALVEOFM OUTDOOR FAN MOTOR

RS ROLLOUT SWITCH

TRAN TRANSFORMER

EQUIP_GND

CC1 C2

IDMV

Y

BR

G/Y

CAP 3

QT

COMPT1

T2

T3

L2

L2

L2

L1

C

J2

W

IFO

5AMP G

R

RS

RS

LS

LS

CS

CS

GV

GV

C

IGCCM

BM

FS

RT

Y

BR

FS

LS11 3

RS1 3

LS21 3R

PRIMARY208/230V

TRAN

SECONDARY24V 24VC

230COM

MGVM C

OFM

CAP1

C11 21

13 23

Y

BL

COMPRESSOR PLUG

Y

BL

BL

V

V

GY

BR

G/YBR

BL

CCH

G

NOTES: 1. IF ANY OF THE ORIGINAL WIRES FURNISHED ARE REPLACED, THEY MUST BE REPLACED WITH THE SAME WIRE OR ITS EQUIVALENT. 2. SEE PRICE PAGES FOR THERMOSTATS. 3. USE 75 DEG. COPPER CONDUCTORS FOR FIELD INSTALLATION.

8. REMOVE YELLOW SPLICE WIRE WHEN ECONOMIZER AND ECONOMIZER

11. DEHUMIDIFICATION FEATURE CANNOT BE USED WHEN ECONOMIZER IS INSTALLED.

BK

Y

O

DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICIN

Y

R

G

W

Y1

R

G

W

T−STAT

COLOR CODE

BK BLACKBL BLUEBR BROWNGY GRAYG GREENO ORANGEP PINKR REDV VIOLETW WHITEY YELLOW

BRC

Y

CAP 1 CAPACITOR, COMPCAP 2 CAPACITOR, INDUCER

PRS PRESSURE SWITCH

HIGH

LOW

COM

C

C

FUSE

COM

3AIFB

IFM

G

N

L

C

1 2 43 5

Y

IFB INDOOR FAN BOARD

LGPS LOW GAS PRESSURE SWITCH (WHEN USED)

BR

R

BR

R

G/Y

O

BK

BL

LPS

P

RVS

DFT

DIP SWITCH SETTINGS30 MINUTES 60 MINUTES ON

90

DEFAULT90 MINUTES

OR

OFF

SHIFT

(DEFAULT)

QUIETOROR

60

FIELD SELECTABLE OPTIONS FORTIME PERIOD BETWEEN DEFROSTCYCLES (MINUTES) 1) MOMENTARILY SHORT PINS AND RELEASE TO BYPASS

COMPRESSOR OFF DELAY.2) SHORT FOR 5+ SEC. AND RELEASE FOR FORCED DEFROST.3) PERMANENT SHORT WILL BE IGNORED.

DEFROST WILL TERMINATE IN 30 SEC. IF DFT OPEN.DEFROST WILL TERMINATE NORMALLY IF DFT IS CLOSED.

SPEEDUP

JUMPERED TEST PINS (USE METAL OBJECT)FIELD SPEED−UP CYCLE

1 1 1113 3 3332 2 22230

60

30

120

90

UP

SPEED

P1 P3

P2

CTDDEFROST BOARD (DB)DR

OF2

OF1

0

W2

R

Y

DFT

T2

T1

O

R

Y

C

C

C

BK BR

BR

P

IF USED

DROF1 OF2

G 4

6W

Y1/Y

R

C

3

2

1

P1

3

C

X 5

W

4R

24V

P2

1

2

Y

BR

BR

BR

R

Y

O

BR

R

R

BK Y

W

R

GY

Y

GY

W

R

INDOOR BLOWER24V CONNECTIONSSEE NOTE 4

SEE NOTE 4

CCH CRANK CASE HEATER

LPS LOW PRESSURE SWITCH

HPS HIGH PRESSURE SWITCH

T−STAT THERMOSTAT

5

BK

R

BL

P O

R

FUSE

120 MINUTES

DB DEFROST BOARD RVS REVERSING VALVEDFT DEFROST TEMPERATURE SWITCH

DR DEFROST BOARD RELAY

LS2 SECONDARY LIMIT SWITCH

BK

BKBK

BK

BK

BK

BK

BK

BL

BK

SATBL

BL

ECON

R

1

2

3

R

BR

Y

GY

GROUNDEDTHRU STANDOFF

CR

BL

R ECON RELAYR1 ECON RELAY

GVR

I

R1

1

2

3

Y

Y2

Y

BK

Y

Y

BK

R1C1 C2

RC1 C2

SEE NOTE 6

SEE NOTE 5

GASHEAT

SEENOTE 7

DH DEHUMIDIFICATION MODE

ECON ECONOMIZER

BLDH Y2/DH

SAT SUPPLY AIR TEMPERATURE

SEE NOTE 10

SEE NOTE 8

SEE NOTE 9

SEE NOTE 11

PRSO

Y

O

LGPS (WHEN USED)

GY

W

BR

R

BR

R

BR

BR

O

W

Y

Y

BR

R

GY

HPSBK BL

7

6

11

10

8

2

3

4

1

5

9

12

ECON PLUG

P

P

DB

THE COMPRESSOR WILL SHUT OFF FOR30 SEC. ON DEFROST INITIATION ANDTERMINATION IN THE ”QUIET SHIFT”ON POSITION.

Page 20: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE20 516 11 2601 03

LADDER WIRING SCHEMATIC − 208/230−3−60

BK

C RS

OFM

CAP

FC

BKDR

OF1 OF2

BK

DB

BR

BK Y

BR

BR

BR

48EZ500124 H

DANGER: ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING

IFM

Y

VRV

Y

21

L1

208/230 VAC, 60 HZ, 3PH

CCH(IF USED)C

1113

COMP

23

T3T1T2

FIELD SUPPLY

BK

Y

YY

BK BK

L2BK

G/YUSE COPPER CONDUCTORS ONLY

G

11

G/Y

TRANPRIMARY 208/230V

230

24V

COM

C

BRIDM

CAP2

CR CMY

G/Y

SECONDARY 24V

5AMPRT

FS

RS

RS

LS

LS

GV

R

W

BL BLRS

LS1 LS2

M C

MGV

GY BR

L2

GV

1

1

1

1

R

G

W

Y1

C

T’STAT

BK Y

V

BK Y

BR

CS

CS

IFO

24VAC R

FUSE3A

P2−1”R”

P1−1”R”

P1−4”G”

P2−5”X”

P1−6”W”

P2−3”W”

P2−4”R”

P1−3”Y1/Y”

LOW

HIGH

12

43

5

IFM

BL

O

BR

COMC

C

COM

IFBP1−2

L1

SEE NOTE 7

IFB

IFB

11

11 23

23Y

IGC

GY

W

R

BK

R

R

BR

P

R

BK

SEE NOTE 4

Y

BL

FS

DBP

P

DFT

Y BL

T1

BLT2

OBK BR

RVS

P3−2

P3−1

C

BR

P2−1

P2−4

P1−6,W2

P1−5,Y

P1−8,O

P1−7,RR

1

O

Y

W

W

BR

FUSE

O

W

IGCIGC

Y

P2−2”C” BR C

DB−C

DB−C

IFB

IFB

IF USED

CIGCG/Y

IGC

C

BL

L3

IFB

OFM

CONTROL BOX AREA

COMP

T1T2

T3

CAP 1

C F

IFM

3 UNIT COMPONENT ARRANGEMENT

OUTDOOR FANSECTION

COMPRESSORSECTION

INDOOR FANSECTION

TRANC

21

23 13

11

LS1

LS1IGC

CAP 2

IDM

I

MGVMC

FS

RS

GASSECTION

(SMALLCABINET)

(LARGE)

LS2(SMALL)

DB

4

2

3

7

5

6

8

Y2

GY

R

ECONHARNESS

BK

BR

P BL

P BLSAT

Y

COM C

R

R1

C

R

1

2

3

R1

1

2

3

BK

Y

Y

C

R R1

SEE NOTE 6

SEE NOTE 5

SEE NOTE 4

1

DH P1−5”Y2/DH”

R

G

W

Y

O

BL

PRS

HPS

LPS

GAS HEAT

SEE NOTE 10

SEE NOTE 11

Y

SEE NOTE 9

SEE NOTE 8

BKLPSHPS

BK BL

PRSY

O O

GY

Page 21: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 21516 11 2601 03

CONTROLSOperating sequenceWhen power is supplied to unit, the transformer (TRAN) isenergized.On units with crankcase heater, heater is also energized.Cooling — With the thermostat subbase in the cooling position,the thermostat makes circuit “R” to “O”. This energizes thereversing valve solenoid (RVS) and places the unit in standbycondition for cooling.As the space temperature rises, the thermostat closes circuit“R” to “Y1/Y”. A circuit is made to contactor (C), starting thecompressor (COMP) and outdoor−fan motor (OFM). Circuit “R”to “G” is made at the same time and starts the indoor−fan motor(IFM).On the loss of the thermostat call for cooling, 24 V is removedfrom both the “Y1/Y” and “G” terminals (provided the fan switchis in the “AUTO” position) de−energizing the compressorcontactor and opening the contacts supplying power tocompressor/OFM. After a 90−second delay, the IFM shuts off. Ifthe thermostat fan selector switch is in the “ON” position, theIFM will run continuously.Heating − On a call for heating, terminal “W” of the thermostat isenergized, starting the induced−draft motor. When the pressureswitch senses that the induced−draft motor is moving sufficientcombustion air, the burner sequence begins. This function isperformed by the integrated gas unit controller (IGC). The indoor(evaporator)−fan motor is energized 45 sec after flame isestablished. When the thermostat is satisfied and “W” isde−energized, the burners stop firing and the indoor(evaporator) fan motor shuts off after a 45−sec time−off delay.Please note that the IGC has the capability to automaticallyreduce the indoor fan motor on delay and increase the indoorfan motor off delay in the event of high duct static and/orpartially−clogged filter.

Heat Pump Heating — On a call for heat, thermostat makescircuits “R” to “Y1/Y” and “R” to “G”.A circuit is made to C, starting COMP and OFM. Circuit “R” to“G” is also completed, starting IFM.Defrost — Defrost board (DB) is a time and temperaturecontrol, which includes a field−selectable time period (dip switch1 and 2 on the board) between checks for defrost (30, 60, 90, or120 minutes). Electronic timer and defrost cycle start only whencontactor is energized and defrost thermostat (DFT) is closed.The defrost board is also equipped with a third dip switch forselecting Quiet Shift operation. The Quiet Shift operation turnscompressor off at defrost initiation and termination. Unit isfactory shipped with quiet shift turned off.Defrost mode is identical to cooling mode. except outdoor fanmotor stops and gas heat turns on to warm air supplying theconditioned space. After defrost cycle, gas heat stays on tomeet the demand cycle.NOTE:

1. Compressor time delay occurs through the defrost controlboard.

2. Defrost control board has built in 5 minute compressordelay; once the compressor has started and then stopped,it cannot be restarted again until 5 minutes have elapsed.

Page 22: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE22 516 11 2601 03

PD(D,S)3 ACCESSORIES

ECONOMIZER, FILTER RACK, and MANUAL OUTSIDE AIR DAMPER

ECONOMIZER

COIL

FILTER

SIDE VIEW

CAULK BOTTOM CORNEROF ECONOMIZERON EACH SIDE

BASE

COIL

FLANGEON BASE DETAIL

ECONOMIZER

FI LTER

EV APORATORCOIL

TOP FILTER RACK

BEND FLANGE AT 90° -SCREW TODIVIDER WITH 1-IN. (25 mm) SCREW

BOTTOM FILTERRACK

DAMPERBLADE

MANUAL OUTSIDEAIR HOOD

REPLACEMENTPANEL

ECONOMIZER

FILTER RACK

MANUAL OUTSIDE AIR DAMPER

Horizontal Economizer

Vertical Economizer

Page 23: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE 23516 11 2601 03

PD(D,S)3 ACCESSORIES

ROOF CURBS

C

B

A

F

D

E

LARGE CURB

C

B

A

F

DE

SMALL CURB

ROOF CURB DETAIL

Wood nailer*

Roofcurb*

Insulation(field supplied)

*Provided with roofcurb

Cant stripfield supplied

Roofing materialfield supplied

Flashing fieldsupplied

HVAC unitbase rails

Roofcurb

SealingGasket

HVAC unitbasepan

Anchor screw

A09090

A09095

A09110

UNIT SIZE CATALOGNUMBER

AIN. (mm)

BIN. (mm)*

CIN. (mm)

DIN. (mm)

EIN. (mm)

FIN. (mm)

SmallCPRFCURB010A00 11 (279)

10 (254)16 (406) 47.8 (1214)

32.4 (822)2.7 (69)

CPRFCURB011A00 14 (356)

LargeCPRFCURB012A00 11 (279)

14 (356) 43.9 (1116)CPRFCURB013A00 14 (356)

NOTES:1. Roof curb must be set up for unit being installed.

2. Seal strip must be applied, as required, to unit being installed.

3. Roof curb is made of 16−gauge steel.

4. Attach ductwork to curb (flanges of duct rest on curb).

5. Insulated panels: 1−in. (25.4 mm) thick fiberglass 1 lb. density.

IMPORTANT: Do not install large base pan Dual Fuel units onto the small base pan (common curb). The center of gravity on a largebase pan Dual Fuel unit could overhang the curb causing an unsafe condition. Before installing any large base pan unit onto thecommon curb, check the “Y” distance in the dimensional drawing to ensure that “Y” is greater than 14 in. (356 mm). Do not install anylarge base pan unit onto the common curb with a “Y” dimension(center of gravity) less than 14 in. (356 mm).

Page 24: OUND R E F R I G E R ANT PDD3, PDS3 S Y L A T N E M N O R ... · dicates a manufacturer’s participation in the program. For verification of certi-fication for individual products,

International Comfort Products, LLCLewisburg, Tennessee 37091 USA

www.GoHeil.comSPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE24 516 11 2601 03

PD(D,S)3 ACCESSORIES (continued)Accessory Model Number Description Use With

ROOF CURBSCPRFCURB010A00 Roof Curb, 11” High 30, 36

CPRFCURB011A00 Roof Curb, 14” High 30, 36

CPRFCURB012A00 Roof Curb, 11” High 42 − 60

CPRFCURB013A00 Roof Curb, 14” High 42 − 60

Note: CPRFCURB010A00 AND CPRFCURB011A00 can be used with 42−60 size units with some overhang.ADAPTER CURBS*

CPADCURB001A00 Adapter curb for use with NPRFCURB006A00 & NPRFCURB007A00 30, 36

CPADCURB002A00 Adapter curb for use with NPRFCURB008A00 & NPRFCURB009A00 42 − 60

* Can also be used when replacing other manufacturer’s older generation units that contain a composite base without a metal base rail.

CONCENTRIC ADAPTERS − (Use with curb only)NPCONADP001A00 For 18” round duct (use with curbs CPRFCURB010A00, CPRFCURB011A00) Small Curb

NPCONADP002A00 For 18” round duct (use with curbs CPRFCURB012A00, CPRFCURB013A00) Large Curb

CONCENTRIC DIFFUSERS − (Ceiling or under roof)AXB020CSA* Step Down Diffuser − Fits 2’ x 4’ Ceiling Grid (16” round collars for flex conn.) 30 − 42

AXB020CFA* Flush Mount Diffuser − Fits 2’ x 4’ Ceiling Grid (16” round collars for flex conn.) 30 − 42

AXB030CSA Step Down Diffuser − Fits 2’ x 4’ Ceiling Grid (18” round collars for flex conn.) 30 − 60

AXB030CFA Flush Mount Diffuser − Fits 2’ x 4’ Ceiling Grid (18” round collars for flex conn.) 30 − 60

* A field supplied 18” to 16” round reducer required when used with NP concentric adaptor

ECONOMIZERSCPECOMZR007A00 Dedicated Vertical Economizer − Internal with solid state controller, gear driven, fully

modulating damper, spring return actuator, up to 50% barometric relief, supply and drybulb outdoor air sensors. Includes filter rack with 1” filters*.

30, 36CPECOMZR008A00 42, 48CPECOMZR009A00 60CPECOMZR010A00 Dedicated Horizontal Economizer − Internal with solid state controller, fully modulating

damper, spring return actuator, supply and dry bulb outdoor air sensor, and lowambient compressor lockout switch included. Includes filter rack with 1−inch filters*.

30, 36CPECOMZR011A00 42, 48CPECOMZR012A00 60CPRLYKIT001A00 Economizer Relay for Heat Pumps ALL

AXB078ENT Outdoor Enthalpy Control ALL

* Outdoor enthalpy available as field installed accessory; Filter rack and 1” filter, same as CPFILTRK kit

DAMPERSCPMANDPR007A00

Manual Outside Air Damper − (Includes filter rack and 1” filter, same as CPFILTRK kit)

30, 36CPMANDPR008A00 42, 48CPMANDPR009A00 60

INTERNAL FILTER RACKSCPFILTRK007A00

Internal Filter Rack (includes 1−inch filters)

30, 36CPFILTRK008A00 42, 48CPFILTRK009A00 60

LOW AMBIENT, ANTI−CYCLE TIMER

CPLOWAMB001A00Low Ambient Control − enables cooling system to operate down to 0 Deg. F by cyclingcondenser fan on and off.

ALL

NRTIMEGD001A00 Five Minute Compressor Delay ALL

CRANKCASE HEATER − BELLY BAND TYPE

NPCRKHTR008A00 240V Crankcase Heater (included on 30 size model) 36

NPCRKHTR004A00 240V Crankcase Heater (Included on 42 and 60 size models) 48

GAS CONVERSION KITS

NPLPCONV013A00 Natural to LP Conversion Kit ( 0 − 2000’ ) ALL

NPLPCONV014A00 Natural to LP Conversion Kit ( 2001’ − 6000’ ) ALL

NPNGCONV004A00 LP to Natural Gas Conversion Kit ( 0 − 2000’ ) ALL

FLUE DISCHARGE DEFLECTOR

CRFLUEDS001A00Directs flue gas exhaust 90 degrees upward from current discharge. Designed to allowtighter distances between unit and combustible surfaces. 24 inch Height. AGA certified.

ALL

COIL PROTECTIONNAPA00501GR 3/8” spacing dense wire grilles 30 − 36

NAPA00601GR 3/8” spacing dense wire grilles 42 − 48

NAPA01001GR 3/8” spacing dense wire grilles 60