Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 1

Setup for Bruker MR workstation ParaVision with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (1)............... 5 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 7 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 9 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak Digital Science 969 HQ LASER IMAGER (1)................................................. 11 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 13 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................ 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)............................................................... 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (4,5) ............ 22 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (4,5) ............ 24 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 26 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 28 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Digital Science 969 HQ LASER IMAGER (4,5)............................................... 30 n Kodak DryView 8900 LASER IMAGER......................................................................... 32 n Kodak DryView 8150 LASER IMAGER......................................................................... 34 n Kodak Color Medical Imager 1000 ................................................................................. 36

1 setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 3: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 2

Bruker MR ParaVision workstation via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_DryView_8300 n and set File/Configure Printer: n IP Address=accordingly, Port Number=104, n AE Title=K8300, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT=0,10, Smoothing Type=0, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=8INx10IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=1 n on 8300 Service Menu into Configure User set:

n Modality Group=0, Async=Enable

Bruker MRParaVision platform

Kodak DryView 8300

DICOM Network

Page 4: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 3

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_9410_DryView_8500 n and set File/Configure Printer: n IP Address=accordingly, Port Number=1024, n AE Title=9410, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=11INx14IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users:

Bruker MRParaVision platform

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 5: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 4

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=Yes n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 6: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 5

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Min. Requirements: Bruker MR ParaVision platform v2.1 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into 9410 Local Printers Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_9410_DryView_8700 n and set File/Configure Printer: n IP Address=accordingly, Port Number=1024, n AE Title=9410, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users:

Bruker MRParaVision platform

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 7: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 6

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=Yes n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 8: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 7

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 9410 v1.6, 8100 v2.4.1 Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_9410_DryView_8100 n and set File/Configure Printer: n IP Address=accordingly, Port Number=1024, n AE Title=9410, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Bruker MRParaVision platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 9: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 8

n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=Yes n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 10: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 9

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_9410_DryView_8300 n and set File/Configure Printer: n IP Address=accordingly, Port Number=1024, n AE Title=9410, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT=u1_109b.w8u,10, Smoothing Type=0, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=8INx10IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Bruker MRParaVision platform

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 11: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 10

n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=Yes n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 12: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 11

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 9410 v1.6, HQ 969 v5.2 Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_9410_HQ_969 n and set File/Configure Printer: n IP Address=accordingly, Port Number=1024, n AE Title=9410, My AE Title=Bruker (from v3.0) n Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=969, Model=969, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=969, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=969, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Bruker MRParaVision platform

Kodak 9410 PACS Link

DICOM Network

Fiber Cable

Fiber Cable

Kodak M969 HQ

3 M H Q L a s e r I m a g e r

Page 13: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 12

n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 14: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 13

Bruker MR ParaVision workstation via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 190 rel. 1.7.29 Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MLP_190 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_190, My AE Title=Bruker (from v3.0) n Film Destination=Magazine, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Smoothing Type=NORMAL, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Bruker MRParaVision platform

DICOM Network

Kodak 190 camera

Page 15: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 14

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, KELI 160 v7.2 Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_KELI_160 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_160, My AE Title=Bruker (from v3.0) n Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=CS435\CN0, Smoothing Type=NORMAL, n Border Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Bruker MRParaVision platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 16: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 15

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 17: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 16

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, 2180 rel. 2.17H Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_KELP_2180 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_2180, My AE Title=Bruker (from v3.0) n Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=CS435\CN0, Smoothing Type=NORMAL, n Border Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On

Bruker MRParaVision platform

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 18: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 17

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 19: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 18

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_KELP_1120 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_1120, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=CS435\CN0, Smoothing Type=NORMAL, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On

Bruker MRParaVision platform

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 20: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 19

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 21: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 20

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM 200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_DryView_8200 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_8200, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On

Bruker MRParaVision platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 22: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 21

n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 23: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 22

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_DryView_8500 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_8500, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=11INx14IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None

Bruker MRParaVision platform

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 24: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 23

n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports= On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=11INx14IN (Always=N), Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 25: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 24

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into MIM200 Destination Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_DryView_8700 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_8700, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None

Bruker MRParaVision platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 26: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 25

n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 27: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 26

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_DryView_8100 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_8100, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On

Bruker MRParaVision platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 28: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 27

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 29: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 28

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_DryView_8300 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_8300, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT=u1_109b.w8u,10, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=8INx10IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On

Bruker MRParaVision platform

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 30: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 29

n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports= On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Film Output Dest=Bin 9 (Always=N)

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 31: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 30

Bruker MR ParaVision workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: MIM200 v6.1, HQ 969 v5.2 Note: This setup is basically also valid for 25 PS computer Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_HQ_969 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_969, My AE Title=Bruker (from v3.0) n Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 969, Set: n General: Log.Name=969 n General: Database Name=969, Model=969, Memory=32 n Media Info: Media=35x43cm, 4096x5002, 4912, Blue n Media Info: Media= 11x14in, 3030x4096, 4006, Blue n Media Info: Media= 8x10in, 2086x2929, 2839, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60

Bruker MRParaVision platform

DICOM Network

Fiber Cable

Fiber Cable

Kodak M969 HQ

3 M H Q L a s e r I m a g e r

Kodak MIM 200

Page 32: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 31

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.3457 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports= On (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 33: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 32

Bruker MR ParaVision workstation via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=eg Kodak_MIM200_DryView_8200 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=NER_8900, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsv3k.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On

Bruker MRParaVision platform

DICOM Network

Kodak DryView 8900

Page 34: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 33

n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mr

Page 35: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 34

Bruker MR ParaVision workstation via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Bruker MR ParaVision platform v2.1 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=eg Kodak_MIM200_DryView_8200 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=DV8150, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT= Pmsb.w87,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=14INx17IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On,

Bruker MRParaVision platform

DICOM Network

Kodak DryView 8150

Page 36: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 35

n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mr

Page 37: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 36

Bruker MR ParaVision workstation via DICOM with Kodak Color Medical Imager 1000

Requirements: Bruker MR ParaVision platform v2.1 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Bruker (ParaVision v2.1) Setup: n Into Camera Tool click on the window n Set Choose Printer=Kodak_MIM200_DryView_8300 n and set File/Configure Printer: n IP Address=accordingly, Port Number=5040, n AE Title=CMI1000, My AE Title=Bruker (from v3.0) n Film Destination=Processor, Medium type=Blue Film, Magnif.Type=Cubic n Camera Image Scaling=1 (ie not scaled), Max Density=300 n Config.Info=LUT=0,9, Smoothing Type=2, n Border Density=Black, Empty Density=Black, Trim=Off n Choose Layout ie format=4:1, Orientation=Portrait, Filmsize=8INx10IN n and set File/Setup Film : Priority=Low, Polarity=Normal, Copies=1 CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N)

Bruker MRParaVision platform

DICOM Network

Kodak CMI 1000

Page 38: Other OEM Setup Manuals

Bruker MR workstation ParaVision with LASER IMAGERS

Author: [email protected], Edition: May ´05 37

n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 39: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Delft workstation Digidelca / Thorascan with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER......................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER......................................................................... 10 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER .......................................................................... 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (1).................................................................... 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 22

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 24

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 26

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 28

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 30

n Kodak DryView 8900 LASER IMAGER......................................................................... 32 n Kodak DryView 8150 LASER IMAGER......................................................................... 34 n Kodak Color Medical Imager 1000 ................................................................................. 36

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 40: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Digidelca / Thorascan via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Delft Setup: n Inside DV8300.tcl file set parameters: n Set theirAE 8300 n Set theirAddress “accordingly:104” n Set filmsize 8INX10IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 0 n Set config “LUT=0,10” n Inside Print.bat file set following: hpclient.exe DV8300.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: a) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=2676, ident=8x10, name=Kodak 8300 8x10, path=D:\spool_P pixelsize_in_unit=0.085, type=dicomprint, unit=mm, width=2256

b) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8300 8x10, Print Mode=True Size, Orient.=eg Portrait

8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=0 ie Auto n on 8300 Service Menu into Configure User set:

n Modality Group=0

Kodak DryView 8300

DICOM Network

Delft Imaging Systems- Digidelca- Thorascan

Page 41: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Digidelca / Thorascan via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 190 rel. 1.7.29 Delft Setup: n Inside K190.tcl file set parameters: n Set theirAE 190 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “CS435\CN0\PD1.2” n Inside Print.bat file set following: hpclient.exe K190.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: c) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5120, ident=14x17, name=Kodak 190 14x17, path=D:\spool_P pixelsize_in_unit=0.080, type=dicomprint, unit=mm, width=4096

d) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 190 14x17, Print Mode=True Size, Orient.=eg Portrait

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

DICOM Network

Kodak 190 cameraDelft Imaging Systems- Digidelca- Thorascan

Page 42: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Digidelca / Thorascan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Delft Setup: n Inside DV8700.tcl file set parameters: n Set theirAE 9410 n Set theirAddress “accordingly:1024” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8700.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: e) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5220, ident=14x17, name=Kodak 8700 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4096

f) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8700 14x17, Print Mode=True Size, Orient.=eg Portrait

9410 Setup:

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Delft Imaging Systems- Digidelca- Thorascan

Page 43: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 44: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Digidelca / Thorascan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Delft Setup: n Inside DV8500.tcl file set parameters: n Set theirAE 9410 n Set theirAddress “accordingly:1024” n Set filmsize 11INX14IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8500.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: g) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=4280, ident=11x14, name=Kodak 8500 11x14, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=3380

h) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8500 11x14, Print Mode=True Size, Orient.=eg Portrait

Kodak DryView 8500 Plus

Kodak 9410 PACS Link

DICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Delft Imaging Systems- Digidelca- Thorascan

Page 45: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 46: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Digidelca / Thorascan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 9410 v1.6, 8100 v2.4.1 Delft Setup: n Inside DV8100.tcl file set parameters: n Set theirAE 9410 n Set theirAddress “accordingly:1024” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8100.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: i) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5216, ident=14x17, name=Kodak 8100 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4096

j) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8100 14x17, Print Mode=True Size, Orient.=eg Portrait

9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Delft Imaging Systems- Digidelca- Thorascan

Page 47: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 48: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Digidelca / Thorascan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Delft Setup: n Inside DV94108300.tcl file set parameters: n Set theirAE 9410 n Set theirAddress “accordingly:1024” n Set filmsize 8INX10IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 0 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV94108300.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: k) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=2676, ident=8x10, name=Kodak 8300 8x10, path=D:\spool_P pixelsize_in_unit=0.085, type=dicomprint, unit=mm, width=2256

l) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8300 8x10, Print Mode=True Size, Orient.=eg Portrait

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Delft Imaging Systems- Digidelca- Thorascan

Page 49: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 50: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Digidelca / Thorascan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Delft Setup: n Inside DV8610.tcl file set parameters: n Set theirAE 9410 n Set theirAddress “accordingly:1024” n Set filmsize 8INX10IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 1 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8610.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: m) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=6200, ident=8x10, name=Kodak 8610 8x10, path=D:\spool_P pixelsize_in_unit=0.039, type=dicomprint, unit=mm, width=5024

n) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8610 8x10, Print Mode=True Size, Orient.=eg Portrait

9410 Setup: n on Device Setup, LOCAL PRINTERS:

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Delft Imaging Systems- Digidelca- Thorascan

Page 51: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=300, Contrast=5, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=5, Max.Density=300 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=11, Contrast=5, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 52: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM 200 v6.1, KELI 160 v5.2 Delft Setup: n Inside K160.tcl file set parameters: n Set theirAE 160 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “CS435\CN0” n Inside Print.bat file set following: hpclient.exe K160.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: o) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5348, ident=14x17, name=Kodak 160 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4360

p) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 160 14x17, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 cameraDelft Imaging Systems- Digidelca- Thorascan

Page 53: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Interpolation=Cubic, Image Polarity=Normal (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 54: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM 200 v6.1, 2180 rel. 2.17H Note: in case another filmsize eg 11x14 is needed, another eg camera_1114.tcl file must be generated with the parameter set to the correspondent 11x14 filmsize, and a second printer eg camera_1114 with same IP address must be installed on Delft Delft Setup: n Inside K2180.tcl file set parameters: n Set theirAE 2180 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “CS435\CN0” n Inside Print.bat file set following: hpclient.exe K2180.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: q) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5156, ident=14x17, name=Kodak 2180 14x17, path=D:\spool_P pixelsize_in_unit=0.079, type=dicomprint, unit=mm, width=4096

r) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 2180 14x17, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup:

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 cameraDelft Imaging Systems- Digidelca- Thorascan

Page 55: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 56: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM 200 v6.1, 1120 rel. 2.40/032 Note: in case another filmsize eg 11x14 is needed, another eg camera_1114.tcl file must be generated with the parameter set to the correspondent 11x14 filmsize, and a second printer eg camera_1114 with same IP address must be installed on Delft Delft Setup: n Inside K1120.tcl file set parameters: n Set theirAE 1120 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “CS435\CN0” n Inside Print.bat file set following: hpclient.exe K1120.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: s) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5132, ident=14x17, name=Kodak 1120 14x17, path=D:\spool_P pixelsize_in_unit=0.080, type=dicomprint, unit=mm, width=4096

t) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 1120 14x17, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup:

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 cameraDelft Imaging Systems- Digidelca- Thorascan

Page 57: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 58: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM 200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: in case another filmsize eg 11x14 is needed, another eg camera_1114.tcl file must be generated with the parameter set to the correspondent 11x14 filmsize, and a second printer eg camera_1114 with same IP address must be installed on Delft Delft Setup: n Inside DV8200.tcl file set parameters: n Set theirAE 8200 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8200.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: u) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5220, ident=14x17, name=Kodak 8200 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4360

v) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8200 14x17, Print Mode=True Size, Orient.=eg Portrait

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Delft Imaging Systems- Digidelca- Thorascan

Page 59: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Blue n Media Info: Media=35x35cm, 4361x4247, 4157, Blue n Media Info: Media=11x14in, 3272x4361, 4271, Blue n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On n Formatting: Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20 n Formatting: Max Img Col=0, Max Img Row=0, n Formatting: Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.1 n SCU: Density Space= On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at Keypad connected to MIM, press Menu, Service Menu, SCP Services: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Ver693c0.w87 (Always=Y), Contrast (dry)=6 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87

Page 60: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 61: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Delft Setup: n Inside DV8700.tcl file set parameters: n Set theirAE 8700 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8700.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: w) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5220, ident=14x17, name=Kodak 8700 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4096

x) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8700 14x17, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup:

Kodak DryView 8700 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Delft Imaging Systems- Digidelca- Thorascan

Page 62: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 63: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Delft Setup: n Inside DV8500.tcl file set parameters: n Set theirAE 8500 n Set theirAddress “accordingly:5040” n Set filmsize 11INX14IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8500.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: y) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=4280, ident=11x14, name=Kodak 8500 11x14, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=3380

z) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8500 11x14, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup:

Kodak DryView 8500 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Delft Imaging Systems- Digidelca- Thorascan

Page 64: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 65: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Delft Setup: n Inside DV8100.tcl file set parameters: n Set theirAE 8100 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8100.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: aa) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5216, ident=14x17, name=Kodak 8100 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4096

bb) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8100 14x17, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Kodak DryView 8100

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Kodak MIM 200

Delft Imaging Systems- Digidelca- Thorascan

Page 66: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 67: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Delft Setup: n Inside DV94108300.tcl file set parameters: n Set theirAE 8300 n Set theirAddress “accordingly:5040” n Set filmsize 8INX10IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 0 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV94108300.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: cc) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=2676, ident=8x10, name=Kodak 8300 8x10, path=D:\spool_P pixelsize_in_unit=0.085, type=dicomprint, unit=mm, width=2256

dd) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8300 8x10, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Kodak DryView 8300

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Delft Imaging Systems- Digidelca- Thorascan

Page 68: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 69: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Digidelca / Thorascan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Delft Setup: n Inside DV8610.tcl file set parameters: n Set theirAE 8610 n Set theirAddress “accordingly:5040” n Set filmsize 8INX10IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 1 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8610.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: ee) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=6200, ident=8x10, name=Kodak 8610 8x10, path=D:\spool_P pixelsize_in_unit=0.039, type=dicomprint, unit=mm, width=5024

ff) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8610 8x10, Print Mode=True Size, Orient.=eg Portrait

MIM200 Setup:

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Delft Imaging Systems- Digidelca- Thorascan

Page 70: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=upmsv3kp.w8u (Always=N), Contrast (dry)=5 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=mr n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 71: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

Digidelca / Thorascan via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: in case another filmsize eg 11x14 is needed, another eg camera_1114.tcl file must be generated with the parameter set to the correspondent 11x14 filmsize, and a second printer eg camera_1114 with same IP address must be installed on Delft Delft Setup: n Inside eg DV8200.tcl file set parameters: n Set theirAE 8900 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8200.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: gg) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5464, ident=14x17, name=Kodak 8900 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4488

hh) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8900 14x17, Print Mode=True Size, Orient.=eg Portrait

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly

DICOM Network

Kodak DryView 8900

Delft Imaging Systems- Digidelca- Thorascan

Page 72: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 73: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

Digidelca / Thorascan via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: in case another filmsize eg 11x14 is needed, another eg camera_1114.tcl file must be generated with the parameter set to the correspondent 11x14 filmsize, and a second printer eg camera_1114 with same IP address must be installed on Delft Delft Setup: n Inside eg DV8200.tcl file set parameters: n Set theirAE DV8150 n Set theirAddress “accordingly:5040” n Set filmsize 14INX17IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 2 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV8200.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: ii) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=5390, ident=14x17, name=Kodak 8150 14x17, path=D:\spool_P pixelsize_in_unit=0.078, type=dicomprint, unit=mm, width=4438

jj) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak 8150 14x17, Print Mode=True Size, Orient.=eg Portrait

8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly

DICOM Network

Kodak DryView 8150

Delft Imaging Systems- Digidelca- Thorascan

Page 74: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 75: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Digidelca / Thorascan via DICOM with Kodak Color Medical Imager 1000

Requirements: HyperPACS platform, OWS v1.2, HyperVIEW v4.1, hpClient v1.05 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Delft Setup: n Inside DV94108300.tcl file set parameters: n Set theirAE CMI1000 n Set theirAddress “accordingly:5040” n Set filmsize 8INX10IN n Set magnification CUBIC n Set border BLACK n Set emptyImage BLACK n Set trim NO n Set maxDensity 260 n Set smoothing 0 n Set config “LUT=0,0” n Inside Print.bat file set following: hpclient.exe DV94108300.tcl n For the image quality select on Delft Service CD the file LUT_KODAK_20.txt (which is

the recommended default setting) and copy this file into Delft under hpw directory and rename this file as LUT.txt

n To print True Size: kk) printer matrix and spot must be defined under Windows with regedit into

HKEY_LOCAL_MACHINE\SOFTWARE\ROGAN\ROGPRINT\Device0: height=if A4 then 3134 (or if 8.5inx11in then 2954), ident=8x10, name=Kodak CMI1000 8x10, path=D:\spool_P pixelsize_in_unit=0.081, type=dicomprint, unit=mm, width=2508

ll) into Delft application select the Tool icon ie Printer Settings and set: Select Printer=Kodak CMI1000 8x10, Print Mode=True Size, Orient.=eg Portrait

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly

DICOM Network

Delft Imaging Systems- Digidelca- Thorascan

Kodak CMI 1000

Page 76: Other OEM Setup Manuals

Delft workstation Digidelca / Thorascan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 77: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for Digithurst Print Server with LASER IMAGERS

Note: Digithurst Print Server translates Postscript protocol coming from Siemens MagicView or Siemens Opdima (in this case TFT=PMS, C=9) into 952 protocol for cameras

Connection POINT-TO-POINT: n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual Printer ..................................................... 2 n Kodak DryView 8700 LASER IMAGER / Plus ................................................................. 3 n Kodak DryView 8700 LASER IMAGER / Standard ......................................................... 4 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual Printer ..................................................... 5 n Kodak DryView 8500 LASER IMAGER / Plus ................................................................. 6 n Kodak DryView 8500 LASER IMAGER / Standard ......................................................... 7 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual Printer ..................................................... 8 n Kodak DryView 8300 LASER IMAGER / Standalone ...................................................... 9 n Kodak Digital Science 969 HQ LASER IMAGER ....................................................... 10 n Kodak Digital Science 969 HQT LASER IMAGER..................................................... 11 n Kodak Digital Science 959 XL LASER IMAGER ........................................................ 12 n Kodak DryView 8100 LASER IMAGER.......................................................................... 13

Page 78: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Digithurst Print Server with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual

RS232 25-to-9 pin Host Adaptor Cable Siemens MagicView

8700 Dual

37-pin Digital Cable

Digithurst Print Server

Local Network

3 M 8 7 0 0 D r y V i e w

UKEIB

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

Requirements: Siemens MagicView rel. VA31B, 8800 rel. 4.2, 8700 rel. 1.34 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8700 8800/8700 Dual Setup: n on UKEIB:

n Jumpers=OFF/ON/OFF/OFF/ON/OFF, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on EIB Menu:

n Parity=Disable, Timeout=60

Page 79: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

Digithurst Print Server with Kodak DryView 8700 LASER IMAGER / Plus

RS232 25-to-9 pinHost Adaptor Cable

Siemens MagicView

8700 Plus

37-pin Digital Cable

DigithurstPrint Serever

Local Network

3M8700 DryViewDEIB

UKEIB

Fiber Cable

Fiber Cable

Requirements: Siemens MagicView rel. VA31B, 8700 rel. 1.34 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8700 8700 Plus Setup: n on UKEIB:

n Jumpers=OFF/ON/OFF/OFF/ON/OFF, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=60

Page 80: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

Page 81: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

Digithurst Print Server with Kodak DryView 8700 LASER IMAGER / Standard

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

8700 Standard

37-pin Digital Cable

DigithurstPrint Server

Local Network

3M 8700DryView

Requirements: Siemens MagicView rel. VA31B, 8700 rel. 1.34 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8700 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=60

Page 82: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

Page 83: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

Digithurst Print Server with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

8500 Dual

37-pin Digital Cable

DigithurstPrint Server

Local Network

3M8700DryView

UKEIB

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

3M 8800Mul ti- Input Manager

Requirements: Siemens MagicView rel. VA31B, 8800 rel. 5.1, 8500 rel. 1.34 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8500 8800/8500 Dual Setup: n on UKEIB:

n Jumpers=OFF/ON/OFF/OFF/ON/OFF, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on EIB Menu:

Page 84: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

n Parity=Disable, Timeout=60

Page 85: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

Digithurst Print Server with Kodak DryView 8500 LASER IMAGER / Plus

RS232 25-to-9 pinHost Adaptor Cable

Siemens MagicView

8500 Plus

37-pin Digital Cable

DigithurstPrint Server

Local Network

3M8700 DryViewDEIB

UKEIB

Fiber Cable

Fiber Cable

Requirements: Siemens MagicView rel. VA31B, 8500 rel. 1.34 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8500 8500 Plus Setup: n on UKEIB:

n Jumpers=OFF/ON/OFF/OFF/ON/OFF, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu: Parity=Disable, Timeout=60

Page 86: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

Page 87: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

Digithurst Print Server with Kodak DryView 8500 LASER IMAGER / Standard

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

8500 Standard

37-pin Digital Cable

DigithurstPrint Server

Local Network

3M 8700DryView

Requirements: Siemens MagicView rel. VA31B, 8500 rel. 1.34 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8500 8500 Standard Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=60

Page 88: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

Digithurst Print Server with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual

RS232 25-to-9 pin Host Adaptor Cable Siemens MagicView

8300 Dual

37-pin Digital Cable

Digithurst Print Server

Local Network

UKEIB

DEIB Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB 37- pin Digital Cable

9-to-9-pin Copper Cable

Requirements: Siemens MagicView rel. VA31B, 8800 rel. 5.1, 8300 rel. 4.4

MagicView Setup: declare ima1-ps as network printer

Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8300

8300 Setup: n on 8300 Operator Menu set:

n Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n Modality Group=4

8800 Setup: n on UKEIB:

n Jumpers=OFF/ON/OFF/OFF/ON/OFF, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n Contrast=1, Density=16 n on HOST Menu:

n Pixel Correction=Yes, Scale Format=Yes, Scale Magnification=Yes n on EIB Menu:

Page 89: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 13

n Parity=Disable, Timeout=60

Page 90: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 14

Digithurst Print Server with Kodak DryView 8300 LASER IMAGER / Standalone

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

8300 Standalone

37-pin Digital Cable

DigithurstPrint Server

Local Network

Requirements: Siemens MagicView rel. VA31B, 8300 rel. 4.4 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8300 8300 Setup: n on 8300 Operator Menu set:

n Density=16 n Contrast=1 n Film Layout: Format=1on 1, Mode=Portrait

n on 8300 Service Menu set: n Serial Control Interface: Baud Rate=9600, Nbr. of Data bits=8,

Nbr. of Stop bits=1, Parity=Even, Protocol=3M n Digital Interface: Parity=None n Modality Group=4

Page 91: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 15

Digithurst Print Server with Kodak Digital Science 969 HQ LASER IMAGER

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

37-pin Digital Cable

DigithurstPrint Server

Local Network

UKEIB

DEIB

Fiber Cable

Fiber Cable

M969 HQ

3 M H Q L a s e r I m a g er

Requirements: Siemens MagicView rel. VA31B, M969 HQ rel. 5.2

MagicView Setup: declare ima1-ps as network printer

Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 969

Important Note:

Only 1 film size can be used. It should be configured at Digithurst Print Sooler. Also at 969 HQ Local Keypad select same Media Size and push SET button.

If customer wants to work with another film size, this should be reconfigured at Digihurst Print Spooler and at 969 Local Keypad.

M969 HQ Setup: n on UKEIB:

n Jumpers=OFF/ON/OFF/OFF/ON/OFF, Switch=Center n on COMM Menu: 959 Default n on IMAGE Menu: TFT=SIEWS87B, Dmax=3.00, Contrast=2, Density=14 n on HOST Menu: Pixel Correct=Yes, Scale Format=Yes, Scale Magnif=Yes n on EIB Menu: Parity=Disable, Timeout=60

Page 92: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 16

Digithurst Print Server with Kodak Digital Science 969 HQT LASER IMAGER

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

M969 HQT

37-pin Digital Cable

DigithurstPrint Server

Local Network

3 M H Q L a s e r I m a g e r

Requirements: Siemens MagicView rel. VA31B, HQT rel. 1.00 Note: in case of image quality problems update HQT to rel. 2.0 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 969 M969 HQT Setup: n on TDB/C board:

n Jumpers=RS232, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=TLII, Contrast=5, Density=7, on OIC Menu: Chemistry=1 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Disable, Timeout=60

Page 93: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 17

Digithurst Print Server with Kodak Digital Science 959 XL LASER IMAGER

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

37-pin Digital Cable

DigithurstPrint Server

Local Network

UKEIB

DEIB

Fiber Cable

Fiber Cable

M959 XL

3 M La s er Im a g er

Requirements: Siemens MagicView rel. VA31B, M959 XL rel. 3.8 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 959 M959 XL Setup: n on UKEIB:

n Jumpers=OFF/ON/OFF/OFF/ON/OFF, Switch=Center n on COMM Menu:

n 959 Default n on IMAGE Menu:

n Contrast & Density settings depending on chemistry n LUT on Input Module=TLII_959 (p/n 78.8079.9817.0)

n on EIB Menu: n Parity=Disable, Timeout=60

Page 94: Other OEM Setup Manuals

Digithurst Print Server with some LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 18

Digithurst Print Server with Kodak DryView 8100 LASER IMAGER

Requirements: Siemens MagicView rel. VA31B, 8100 rel. 2.4.1 MagicView Setup: declare ima1-ps as network printer Digithurst Setup: - plug network cable into LAN1 card (look carefully for LAN1 plug) - using Sirius password, setup IPaddr. for 3Com 3C905B-TX, i.e., LAN1 - using Digithurst password, into Toolbox select proper camera, e.g., 8700 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs):

n SW1=Down n on COMMUNICATIONS Menu:

n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu:

n TFT=WRKSTN2A n on LOCAL PANEL Menu:

n Contrast=2, Density=3.00 n on SYSTEM Menu:

n Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu:

n Pixel Depth=8, Header/Line, Parity=Disable

RS232 25-to-9 pinHost Adaptor CableSiemens MagicView

DryView 8100

37-pin Digital Cable

DigithurstPrint Server

Local Network

RS232 9-poleplug

Page 95: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 1

Setup for Dornier workstation Opus / Doli with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (1)............... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 10 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 12

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak Digital Science 969 HQ LASER IMAGER (1)................................................. 14

n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................ 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 21 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 24 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)............................................................... 27 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (4,5) ............ 30 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (4,5) ............ 33 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5) ................................................................. 36 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5) ................................................................. 39 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (4,5) .......................................................................................................... 42

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Digital Science 969 HQ LASER IMAGER (4)................................................. 45

n Kodak DryView 8900 LASER IMAGER......................................................................... 48 n Kodak DryView 8150 LASER IMAGER......................................................................... 51 n Kodak Color Medical Imager 1000 ................................................................................. 54

1 setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 96: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 2

Dornier workstation via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak DryView 8300 n Description=DV8300, AETitle=K8300, IPAddress=accordingly, Port=104, Timeout=50

msec n Grayscale Print: Copies=1, Bits=8, Destination=Processor, Config.Info=LUT=0,10,

Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=0, Trim=No

n Media: Film=8INX10IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=0 n on 8300 Service Menu into Configure User set:

n Modality Group=0

Dornier Workstation

Kodak DryView 8300

DICOM Network

Page 97: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 3

Dornier workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Dornier workstation v1.0 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak 9410 DryView 8500 n Description=DV8500, AETitle=9410, IPAddress=accordingly, Port=1024, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=11INX14IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly

Dornier Workstation

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 98: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 4

n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 99: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 5

Dornier workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Requirements: Dornier workstation v1.0 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into 9410 Local Printers Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak 9410 DryView 8700 n Description=DV8700, AETitle=9410, IPAddress=accordingly, Port=1024, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation : Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users:

Dornier Workstation

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 100: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 6

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 101: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 7

Dornier workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: 9410 v1.6, 8100 v2.4.1 Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak 9410 DryView 8100 n Description=DV8100, AETitle=9410, IPAddress=accordingly, Port=1024, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Dornier Workstation

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 102: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 8

n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 103: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 9

Dornier workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak 9410 DryView 8300 n Description=DV8300, AETitle=9410, IPAddress=accordingly, Port=1024, Timeout=50

msec n Grayscale Print: Copies=1, Bits=8, Destination=Processor,

Config.Info=LUT=u1_109b.w8u,10, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=0, Trim=No

n Media: Film=8INX10IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Dornier Workstation

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 104: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 10

n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 105: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 11

Dornier workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Dornier workstation v1.0 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak 9410 DryView 8610 n Description=DV8610, AETitle=9410, IPAddress=accordingly, Port=1024, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor, Border=Black, Empty

Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=0, Trim=No n Media: Film=8INX10IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=300, Contrast=5, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=5, Max.Density=300

Dornier Workstation

Kodak DryView 8610Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 106: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 12

n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 107: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 13

Dornier workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: 9410 v1.6, HQ 969 v5.2 Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak 9410 HQ 969 n Description=HQ969, AETitle=9410, IPAddress=accordingly, Port=1024,

Timeout=50 msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=969, Model=969, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=969, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=969, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Dornier Workstation

Kodak 9410 PACS Link

DICOM Network

Fiber Cable

Fiber Cable

Kodak M969 HQ

3 M H Q L a s e r I m a g e r

Page 108: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 14

n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 109: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 15

Dornier workstation via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Dornier workstation v1.0 Requirements: 190 rel. 1.7.29 Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MLP 190 n Description=190, AETitle=K190, IPAddress=accordingly, Port=5040

Timeout=50 msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor, Border=Black, Empty

Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=NORMAL, Trim=No n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Dornier Workstation

DICOM Network

Kodak 190 camera

Page 110: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 16

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, KELI 160 v7.2 Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 KELI 160 n Description=K160, AETitle=K160, IPAddress=accordingly, Port=5040

Timeout=50 msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor, Config.Info=CS435\CN0,

Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=NORMAL, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Dornier Workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 111: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 17

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 112: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 18

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 2180 rel. 2.17H Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 KELP 2180 n Description=K2180, AETitle=K2180, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor, Config.Info=CS435\CN0,

Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=NORMAL, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On

Dornier Workstation

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 113: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 19

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 114: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 20

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 KELP 1120 n Description=K1120, AETitle=K1120, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor, Config.Info=CS435\CN0,

Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=NORMAL, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On

Dornier Workstation

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 115: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 21

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 116: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 22

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 DryView 8200 n Description=DV8200, AETitle=K8200, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On

Dornier Workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 117: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 23

n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 118: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 24

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 DryView 8500 n Description=DV8500, AETitle=K8500, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=11INX14IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue

Dornier Workstation

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 119: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 25

n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=11INx14IN (Always=N), Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 120: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 26

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into MIM200 Destination Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 DryView 8700 n Description=DV8700, AETitle=K8700, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Dornier Workstation

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 121: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 27

n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 122: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 28

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 DryView 8100 n Description=DV8100, AETitle=K8100, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Dornier Workstation

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 123: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 29

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 124: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 30

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 DryView 8300 n Description=DV8300, AETitle=K8300, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=8, Destination=Processor,

Config.Info=LUT= u1_109b.w8u,10, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=8INX10IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Dornier Workstation

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 125: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 31

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 126: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 32

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 DryView 8610 n Description=DV8610, AETitle=K8610, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor, Border=Black, Empty

Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=0, Trim=No n Media: Film=8INX10IN, Blue Film: Enable=On, Dmax=300, Dmin=-1 n Formats: 1x1 Rows=-1, Columns=-1, Orientation Landscape=On, Portrait=On n 1x2, 2x2 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Dornier Workstation

Kodak DryView 8610Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 127: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 33

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=upmsv3kp.w8u (Always=Y), Contrast (dry)=5 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n ICCProfile=Off (Always=N), Modality=OT (Always=N) n BodyPart=Default (Always=N), Modality Group=1 n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Conv.Group=1, Gamma Table=1, Smoothing Type=1 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 128: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 34

Dornier workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: MIM200 v6.1, HQ 969 v5.2 Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 HQ 969 n Description=HQ969, AETitle=K969, IPAddress=accordingly, Port=5040, Timeout=50

msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=leave blank n Formats: 1x1 Rows=leave blank, Columns=leave blank n Orientation: Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 969, Set: n General: Log.Name=969 n General: Database Name=969, Model=969, Memory=32 n Media Info: Media=35x43cm, 4096x5002, 4912, Blue n Media Info: Media= 11x14in, 3030x4096, 4006, Blue n Media Info: Media= 8x10in, 2086x2929, 2839, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Dornier Workstation

DICOM Network

Fiber Cable

Fiber Cable

Kodak M969 HQ

3 M H Q L a s e r I m a g e r

Kodak MIM 200

Page 129: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 35

n Interpolation: Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.3457 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 130: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 36

Dornier workstation via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=eg Kodak MIM200 DryView 8200 n Description=DV8900, AETitle=8900, IPAddr=accordingly, Port=5040, Timeout=50 msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsv3k.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=-1 n Formats: 1x1 Rows=-1, Columns=-1, Orientation Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On

Dornier Workstation

DICOM Network

Kodak DryView 8900

Page 131: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 37

n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 132: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 38

Dornier workstation via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Dornier workstation v1.0 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=eg Kodak MIM200 DryView 8200 n Description=DV8150, AETitle=DV8150, IPAddress=accordingly, Port=5040,

Timeout=50 msec n Grayscale Print: Copies=1, Bits=12, Destination=Processor,

Config.Info=LUT=Pmsb.w87,9, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=2, Trim=No

n Media: Film=14INX17IN, Blue Film: Enable=On, Dmax=300, Dmin=-1 n Formats: 1x1 Rows=-1, Columns=-1, Orientation Landscape=On, Portrait=On n 1x2, 2x2, 2x3, 3x4 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On

Dornier Workstation

DICOM Network

Kodak DryView 8150

Page 133: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 39

n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 134: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 40

Dornier workstation via DICOM with Kodak Color Medical Imager 1000

Requirements: Dornier workstation v1.0 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Dornier Setup: n Into DICOM/New/Server Type=Print Server n Choose Template Server=Kodak MIM200 DryView 8300 n Description=CMI1000, AETitle=CMI1000, IPAddress=accordingly, Port=5040,

Timeout=50 msec n Grayscale Print: Copies=1, Bits=8, Destination=Processor,

Config.Info=LUT= u1_109b.w8u,10, Border=Black, Empty Image=Black, Polarity=Normal, Magnification=Cubic, Smoothing=0, Trim=No

n Media: Film=8INX10IN, Blue Film: Enable=On, Dmax=300, Dmin=-1 n Formats: 1x1 Rows=-1, Columns=-1, Orientation Landscape=On, Portrait=On n 1x2, 2x2 CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings:

Dornier Workstation

DICOM Network

Kodak CMI 1000

Page 135: Other OEM Setup Manuals

Dornier workstation for Opus / Doli with LASER IMAGERS

Author: [email protected], Edition: May ´05 41

n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 136: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for EBIT AET workstation DICOMED Review with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER......................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER......................................................................... 10 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) ................................................................................................................. 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER .......................................................................... 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (1).................................................................... 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 22

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 24

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 26

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 28

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 30

n Kodak DryView 8900 LASER IMAGER......................................................................... 32 n Kodak DryView 8150 LASER IMAGER......................................................................... 34 n Kodak Color Medical Imager 1000 ................................................................................. 36

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 137: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

DICOMED Review via DICOM with Kodak DryView 8300 LASER IMAGER

EBIT WorkstationDICOMED Review

Kodak DryView 8300

DICOM Network

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: working only with DICOMED images with 8-bit depth DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., DV8300, Application Entity Type=Print Server n Remote Application Entity Title=8300, Remote AE IPaddr=accordingly n Listen Port=104, Configuration File=Kodak DV8300.ini n Into Dicom Printer Parameters\Printer Name=Kodak DV8300 set : n Bit Allocated Supported: 8 (i.e., only 8 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=0,10 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=DV8300, Film Size=8INx10IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 3x2 table for a 6:1 format to be printed on the film 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set: Modality Group=0

Page 138: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

DICOMED Review via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

EBIT WorkstationDICOMED Review

DICOM Network

Kodak 190 camera

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 190 rel. 1.7.29 DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., Kodak 190, Application Entity Type=Print Server n Remote Application Entity Title=190, Remote AE IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak 190.ini n Into Dicom Printer Parameters\Printer Name=Kodak 190 set : n Bit Allocated Supported: ALL (i.e., both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=CS435\CN0 n Film Box: Trim=NO, Smoothing Type=NORMAL n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=Kodak 190, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 5x4 table for a 20:1 format to be printed on the film 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 139: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

DICOMED Review via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

EBIT WorkstationDICOMED Review

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., DV8700, Application Entity Type=Print Server n Remote Application Entity Title=9410, Remote Application Entity IPaddr=accordingly n Listen Port=1024, Configuration File=Kodak DV8700.ini n Into Dicom Printer Parameters\Printer Name=Kodak DV8700 set : n Bit Allocated Supported: ALL (i.e., both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsv3k.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=DV8700, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 5x4 table for a 20:1 format to be printed on the film 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Page 140: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 141: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

DICOMED Review via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

EBIT WorkstationDICOMED Review

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., DV8500, Application Entity Type=Print Server n Remote Application Entity Title=9410, Remote Application Entity IPaddr=accordingly n Listen Port=1024, Configuration File=Kodak DV8500.ini n Into Dicom Printer Parameters\Printer Name=Kodak DV8500 set : n Bit Allocated Supported: ALL (i.e., both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsv3k.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=DV8500, Film Size=11INx14IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 5x4 table for a 20:1 format to be printed on the film 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Page 142: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 143: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

DICOMED Review via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

EBIT WorkstationDICOMED Review

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 9410 v1.6, 8100 v2.4.1 DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., DV8100, Application Entity Type=Print Server n Remote Application Entity Title=9410, Remote Application Entity IPaddr=accordingly n Listen Port=1024, Configuration File=Kodak DV8100.ini n Into Dicom Printer Parameters\Printer Name=Kodak DV8100 set : n Bit Allocated Supported: ALL (i.e., both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsb.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=DV8100, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 5x4 table for a 20:1 format to be printed on the film 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly

Page 144: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 145: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

DICOMED Review via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

EBIT WorkstationDICOMED Review

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., DV9410_8300, Application Entity Type=Print Server n Remote Application Entity Title=9410, Remote Application Entity IPaddr=accordingly n Listen Port=1024, Configuration File=Kodak DV9410_8300.ini n Into Dicom Printer Parameters\Printer Name=Kodak DV9410_8300 set : n Bit Allocated Supported: 8 (i.e., only 8 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=0,10 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=DV9410_8300, Film Size=8INx10IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 3x2 table for a 6:1 format to be printed on the film 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly

Page 146: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 147: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

DICOMED Review via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

EBIT WorkstationDICOMED Review

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., DV8610, Application Entity Type=Print Server n Remote Application Entity Title=9410, Remote Application Entity IPaddr=accordingly n Listen Port=1024, Configuration File=Kodak DV8610.ini n Into Dicom Printer Parameters\Printer Name=Kodak DV8610 set : n Bit Allocated Supported: ALL (i.e., both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=350, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=0,3 n Film Box: Trim=NO, Smoothing Type=1 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=DV8610, Film Size=8INx10IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 3x2 table for a 6:1 format to be printed on the film 9410 Setup: on SCP PRINTER Menu, Current Provider, SCP Parameters:

n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations=5 n on SCP PRINTER Menu, Registered User: n SCU AETitle=accordingly, SCU IPAddr=accordingly, SCP=8610 n Copies=1, Contrast Table=3, Max.Density=350 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=6, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No

Page 148: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=350, Contrast=3, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 149: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM 200 v6.1, KELI 160 v7.2 DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg Kodak 160, Application Entity Type=Print Server n Remote Application Entity Title=160, Remote AE IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak 160.ini n Into Dicom Printer Parameters\Printer Name= Kodak 160 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=CS435\CN0 n Film Box: Trim=NO, Smoothing Type=NORMAL n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= Kodak 160, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On

EBIT WorkstationDICOMED Review

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 150: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Interpolation=Cubic, Image Polarity=Normal (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 151: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM 200 v6.1, 2180 rel. 2.17H DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg Kodak 2180, Application Entity Type=Print Server n Remote Application Entity Title=2180, Remote AE IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak 2180.ini n Into Dicom Printer Parameters\Printer Name= Kodak 2180 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=CS435\CN0 n Film Box: Trim=NO, Smoothing Type=NORMAL n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= Kodak 2180, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue)

EBIT WorkstationDICOMED Review

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 152: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 153: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM 200 v6.1, 1120 rel. 2.40/032 DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg Kodak 1120, Application Entity Type=Print Server n Remote Application Entity Title=1120, Remote AE IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak 1120.ini n Into Dicom Printer Parameters\Printer Name= Kodak 1120 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=CS435\CN0 n Film Box: Trim=NO, Smoothing Type=NORMAL n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= Kodak 1120, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue)

EBIT WorkstationDICOMED Review

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 154: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 155: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM 200 v6.1, DV8200 v3.5 Note: This setup is basically also valid for 25 PS computer DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV8200, Application Entity Type=Print Server n Remote Application Entity Title=8200, Remote AE IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV8200.ini n Into Dicom Printer Parameters\Printer Name= Kodak DV8200 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsb.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV8200, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Blue

EBIT WorkstationDICOMED Review

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 156: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Media Info: Media=35x35cm, 4361x4247, 4157, Blue n Media Info: Media=11x14in, 3272x4361, 4271, Blue n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On n Formatting: Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20 n Formatting: Max Img Col=0, Max Img Row=0, n Formatting: Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.1 n SCU: Density Space= On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at Keypad connected to MIM, press Menu, Service Menu, SCP Services: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 157: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV8700, Application Entity Type=Print Server n Remote Application Entity Title=8700, Remote Application Entity IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV8700.ini n Into Dicom Printer Parameters\Printer Name= Kodak DV8700 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsv3k.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV8700, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700

EBIT WorkstationDICOMED Review

Kodak DryView 8700 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Page 158: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 159: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV8500, Application Entity Type=Print Server n Remote Application Entity Title=8500, Remote Application Entity IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV8500.ini n Into Dicom Printer Parameters\Printer Name= Kodak DV8500 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsv3k.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV8500, Film Size=11INx14IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500

EBIT WorkstationDICOMED Review

Kodak DryView 8500 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Page 160: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 161: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV8100, Application Entity Type=Print Server n Remote Application Entity Title=8100, Remote Application Entity IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV8100.ini n Into Dicom Printer Parameters\Printer Name= Kodak DV8100 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsb.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV8100, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Kodak DryView 8100

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

EBIT WorkstationDICOMED Review

Kodak MIM 200

Page 162: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 163: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV9410_8300, Application Entity Type=Print Server n Remote Application Entity Title=8300, Remote Application Entity IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV9410_8300.ini n Into Dicom Printer Parameters\Printer Name= Kodak DV9410_8300 set : n Bit Allocated Supported: 8 (ie only 8 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=0,10 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV9410_8300, Film Size=8INx10IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 3x2 table for a 6:1 format to be printed on the film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Kodak DryView 8300

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

EBIT WorkstationDICOMED Review

Kodak MIM 200

Page 164: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 165: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

DICOMED Review via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV8610, Application Entity Type=Print Server n Remote Application Entity Title=8610, Remote Application Entity IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV8610.ini n Into Dicom Printer Parameters\Printer Name= Kodak DV8610 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=350, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=0,3 n Film Box: Trim=NO, Smoothing Type=1 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV8610, Film Size=8INx10IN, n Medium Type=Blue Film, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=eg select a 3x2 table for a 6:1 format to be printed on the film MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600)

EBIT WorkstationDICOMED Review

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 166: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=upmsv3kp.w8u (Always=N), Contrast (dry)=5 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=mr n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 167: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

DICOMED Review via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV8900, Application Entity Type=Print Server n Remote Applic. Entity Title=8900, Remote Applic. Entity IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV8900.ini (or DV8200.ini) n Into Dicom Printer Parameters\Printer Name= Kodak DV8900 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsv3k.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV8900, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnific.Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly n on Configuration, System, Software License:

n License Status=Mammo Key is OFF n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

EBIT WorkstationDICOMED Review

DICOM Network

Kodak DryView 8900

Page 168: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always= N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 169: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

DICOMED Review via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: DICOMED Review rel. 3.0, DICOM level v3.07 Requirements: 8150 v1.0.2.b04 (ie DRE v1.0.2.b04, MIM v5.7.b8) DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=eg DV8150, Application Entity Type=Print Server n Remote Applic. Entity Title=DV8150, Remote Applic. Entity IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak DV 8150.ini (or DV8200.ini) n Into Dicom Printer Parameters\Printer Name= Kodak DV8150 set : n Bit Allocated Supported: ALL (ie both 8 and 12 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsb.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name= DV8150, Film Size=14INx17IN, n Medium Type=Blue Film, Orientation=Portrait, Magnific.Type=Cubic, Copies=1 n Row/Col=eg select a 5x4 table for a 20:1 format to be printed on the film 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

EBIT WorkstationDICOMED Review

DICOM Network

Kodak DryView 8150

Page 170: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 171: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

DICOMED Review via DICOM with Kodak Color Medical Imager 1000

Requirements: DICOMED Review rel. 3.0, DICOM level v3.0.7 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) DICOMED Review Setup: n into Local DB,Configure, into Server Setting Parameters select Add, set: n Application Entity Name=e.g., CMI1000, Application Entity Type=Print Server n Remote Application Entity Title=CMI1000, Remote AE IPaddr=accordingly n Listen Port=5040, Configuration File=Kodak CMI1000.ini n Into Dicom Printer Parameters\Printer Name=Kodak CMI1000 set : n Bit Allocated Supported: 8 (i.e., only 8 bit images are sent) n Film Session: Print Priority=MED, Film Destination=PROCESSOR n Film Box: Max Density=300, Border Density=BLACK, Empty Image=BLACK n Film Box: Config.Information=LUT=Pmsv3k.w87,9 n Film Box: Trim=NO, Smoothing Type=2 n Printer Setting: Magnification=CUBIC n into Print, set: Printer Name=CMI1000, Film Size=A4 (or 8_5INX11IN), n Medium Type=Paper, Orientation=Portrait, Magnification Type=Cubic, Copies=1 n Row/Col=e.g., select a 3x2 table for a 6:1 format to be printed on the film CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP:

DICOM Network

Kodak CMI 1000

EBIT WorkstationDICOMED Review

Page 172: Other OEM Setup Manuals

Setup Manual for EBIT AET workstation DICOMED with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

n under Image Quality, Grayscale Image Quality: n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 173: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Esaote MR Artoscan/Escan (Unix Solaris platform) with LASER IMAGERS Connection POINT-TO-POINT (digital / keypad): n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual.............................................................. 3 n Kodak DryView 8700 LASER IMAGER / Plus............................................................... 4 n Kodak DryView 8700 LASER IMAGER / Standard ....................................................... 5 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual.............................................................. 6 n Kodak DryView 8500 LASER IMAGER / Plus............................................................... 7 n Kodak DryView 8500 LASER IMAGER / Standard ....................................................... 8 n Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual.............................................................. 9 n Kodak DryView 8300 LASER IMAGER / Standalone.................................................... 10 n Kodak Digital Science 969 HQ LASER IMAGER...................................................... 11 n Kodak Digital Science 969 HQT LASER IMAGER ................................................... 12 n Kodak Digital Science 959 XL LASER IMAGER ...................................................... 13 n Kodak DryView 8100 LASER IMAGER......................................................................... 14 n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (not working, DICOM recommended)

n Kodak PACS LINK 9410 ACQUISITION SYSTEM / Kodak DryView 8100 LASER IMAGER (not working, via DICOM recommended)

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER(2,3,4) .................................................................. 15

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER(2,3,4) ............................................................... 17

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER(2,3,4) ............................................................... 19

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4) . 21

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4).................................................................... 23

Page 174: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 25 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 26 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 27 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 29 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 31 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 33 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 35

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 37

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 39

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 41

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)................................................................ 43

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 45

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (4,5) ............ 47

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5).................................................................. 49

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5).................................................................. 51

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (4,5) .......................................................................................................... 53

n Kodak DryView 8900 LASER IMAGER......................................................................... 55 n Kodak DryView 8150 LASER IMAGER......................................................................... 57 n Kodak Color Medical Imager 1000 ................................................................................. 59

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 175: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Esaote MR Artoscan/Escan with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8700 LASER IMAGER / Dual

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote Artoscan MR

8700 DualFiber Cable

3M 8700 DryView

3M8800Multi-In

putManag

er

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8800 rel. 5.1, 8700 rel. 1.22 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8800/8700 Dual Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 176: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Esaote MR Artoscan/Escan with Kodak DryView 8700 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote Artoscan MR

8700 Plus

3M 8700 DryView

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8700 rel. 1.22 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 177: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Esaote MR Artoscan/Escan with Kodak DryView 8700 LASER IMAGER / Standard

Keypad

Digital Board Data output

Data Cable 37-pin

Esaote Artoscan MR

8700 Standard

3M 8700 DryView

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8700 rel. 1.22 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad 8700 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even (if error set to Disable), Timeout=10

Page 178: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Esaote MR Artoscan/Escan with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8500 LASER IMAGER / Dual

DEIB

Fiber Cable

Fiber Cable

8800 MIM

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote Artoscan MR

8500 DualFiber Cable

3M 8700 DryView

3M8800Multi-In

putManag

er

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8800 rel. 5.1, 8500 rel. 1.22 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8800/8500 Dual Setup: n on COMM Menu:

n 969 Default n on IMAGE Menu:

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on EIB Menu:

n Parity=Enable Even (if error set to Disable), Timeout=10

Page 179: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Esaote MR Artoscan/Escan Kodak DryView 8500 LASER IMAGER / Plus

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote Artoscan MR

8500 Plus

3M 8700 DryView

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8500 Plus rel. 1.22 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 180: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Esaote MR Artoscan/Escan with Kodak DryView 8500 LASER IMAGER / Standard

Keypad

Digital Board Data output

Data Cable 37-pin

Esaote Artoscan MR

8500 Standard

3M 8700 DryView

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8500 Standard rel. 1.22 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad 8500 Standard Setup: n on TDB/C board:

n Jumpers=RS422, Switch=Left n on COMM Menu:

n 8700 Keypad Default n on IMAGE Menu:

n TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on SYSTEM Menu:

n Memory Management=Best Fit n on EIB Menu:

n Parity=Enable Even (if error set to Disable), Timeout=10

Page 181: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Esaote MR Artoscan/Escan with Kodak DryView 8800 MULTI-INPUT MANAGER /

Kodak DryView 8300 LASER IMAGER / Dual

DryView 8300 Dual

DEIB

Fiber Cable

Fiber Cable

Fiber Cable

8800 MIM

POEIB37-pin Digital Cable

9-to-9-pin Copper Cable

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote Artoscan MR

3M8800Multi-InputManager

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8800 rel. 5.1, 8300 rel. 4.2 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8300 Setup: n on 8300 Operator Menu set: Film Layout : Format=1on 1, Mode=Portrait n on 8300 Service Menu set:

n Serial Control Interface: Baud Rate=1200, Nbr. of Data bits=8, Nbr. of Stop bits=1, Parity=Even, Protocol=3M

n Digital Interface: Parity=None n Modality Group=0 n

Page 182: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

8800 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: Density=16, Contrast=10 n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 183: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Esaote MR Artoscan/Escan with Kodak DryView 8300 LASER IMAGER / Standalone

Keypad

Digital Board Data outputData Cable 37-pin

Esaote Artoscan MRDryView 8300

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8300 rel. 4.2 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16 n Contrast=10 n Sharp/Smooth=0

n on 8300 Service Menu into Configure User set: n Serial Control Interface: Protocol=Keypad n Digital Interface: Parity=Even (if error set to Disable) n Modality Group=0

Page 184: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Esaote MR Artoscan/Escan with Kodak Digital Science 969 HQ LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M969 HQ

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote Artoscan MR

3 M H Q L a s e r I m a g e r

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: M969 HQ rel. 5.1 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center M969 HQ Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMS, Dmax=3.00, Contrast=9, Density=14 n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 185: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Esaote MR Artoscan/Escan with| Kodak Digital Science 969 HQT LASER IMAGER

Keypad

Digital Board Data output

Data Cable 37-pin

Esaote Artoscan MR

M969 HQT

3 M H Q L a s e r I m a g e r

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: M969 HQT rel. 1.0 Note: in case of image quality problems update HQT to rel. 2.0 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad M969 HQT Setup: n on TDB/C board: Jumpers=RS422, Switch=Left n on COMM Menu: 8700 Keypad Default n on IMAGE Menu: (note: values suitable for 60 secs Kodak APS chemistry)

n TFT=PMS, Contrast=15, Density=7, on OIC Menu: Chemistry=2 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Parity=Enable Even (if error set to Disable), Timeout=10

Page 186: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Esaote MR Artoscan/Escan with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

M959 XL

UKEIB

XL Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote Artoscan MR

3 M L a ser I m a g er

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: M959 XL rel. 3.8 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: n on XL Control Panel set Density & Contrast depending on chemistry n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center n on XL Input Module install LUT 322A0 M959 XL Setup: n on COMM Menu:

n 959 Default n on EIB Menu:

n Parity=Enable Even (if error set to Disable), Timeout=10

Page 187: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Esaote MR Artoscan/Escan with Kodak DryView 8100 LASER IMAGER

Copper Cable

UKEIB

Keypad

Digital Board Data OUT

Keypad

Data Cable 37-pin

Esaote MR- Artoscan- Escan

DryView 8100

Imager

RS422 9-pole Plug

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8100 v1.1 Note: on MR Digital Board, with jumper W12 image data parity is set:

with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd

Note: on MR in case of image acquisition error try to reset the MR Digital Board by entering in Menu: Help->Exposure: Reset Dig. Prn.

To Print: Select an image on MR monitor, press acquire button at camera keypad Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=10, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=2 n on IMAGE QUALITY-> TFT FILES Menu: TFT=PMSB n on LOCAL PANEL Menu: Contrast=9, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Even (if error Disable)

Page 188: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Esaote MR Artoscan/Escan with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board

by entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2

Data Cable 37-pin

Kodak MIM 200

Esaote MRUnix Solaris platform- Artoscan- Escan

Digital BoardData OUT

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

CrossedNetwork Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 189: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

160 Setup: no modality-specific setup needed

Page 190: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Esaote MR Artoscan/Escan with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM 200 v6.1, KELP 2180 v2.17H Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board

by entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On

Data Cable 37-pin

Kodak MIM 200

Esaote MRUnix Solaris platform- Artoscan- Escan

Digital BoardData OUT

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

CrossedNetwork Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 191: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console= On

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 192: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Esaote MR Artoscan/Escan with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board

by entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=1, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On

Data Cable 37-pin

Kodak MIM 200

Esaote MRUnix Solaris platform- Artoscan- Escan

Digital BoardData OUT

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

CrossedNetwork Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 193: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console= On

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 194: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Esaote MR Artoscan/Escan with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM 200 Destinations Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network: n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Jazz: n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On

Keypad

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

Fiber Cable

3M 8700 DryView

Kodak DryView 8700 Plus

RS422 37-to-50 pinDigital Adaptor Cable

Esaote MRUnix Solaris platform- Artoscan- Escan

Digital BoardData OUT

Data Cable 37-pin

Page 195: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Pmsv3k.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 196: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Esaote MR Artoscan/Escan with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 8100 v2.4.1 Note: on MR Digital Board, with jumper W12 image data parity is set: with W12 not inserted (default) Image Parity=Even, with W12 inserted Image Parity=Odd Note: Image Data not lutted by MR, lutted by Camera Note: on MR in case of image acquisition error try to reset the MR Digital Board entering in Menu: Help->Exposure: Reset Dig. Prn. To Print: Select an image on MR monitor, press acquire button at camera keypad MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=Magnetom Jazz: n Board/Channel=Digital Board 1 Channel 1, Logical Name=smr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=1, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

KeypadEsaote MRUnix Solaris platform- Artoscan- Escan

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

RS4229-pole Plug

Kodak DryView 8100

Digital BoardData OUT

Data Cable 37-pinRS422 37-to-50 pinDigital Adaptor Cable

Page 197: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Pmsb.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 198: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Esaote MR Artoscan/Escan via DICOM with Kodak DryView 8300 LASER IMAGER

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8300

DICOM Network

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Contrast=10, Modality Group=0 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=104, Printer AE title=8300

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,10, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 8x10 Size, e.g., 6 images (i.e., Format=6:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film

8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set: Modality Group=0

Page 199: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

Esaote MR Artoscan/Escan via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Esaote MRUnix Solaris platform- Artoscan- Escan

DICOM Network

Kodak 190 camera

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 190 rel. 1.7.29 Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k190, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=190

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 14x17 Size, e.g., 20 images (i.e., Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 200: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMS Artoscan / Escan MR Setup: n in Menu: Help->Service->Option->DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Option/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 14x17 Size, e.g., 20 images (i.e., Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film

Page 201: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 202: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

Esaote MR Artoscan/Escan via DICOM with| Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8500 Plus

Kodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMS Artoscan / Escan MR Setup: n in Menu: Help->Service->Option->DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Option/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 11x14 Size, e.g., 20 images (i.e., Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film

Page 203: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 204: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 9410 v1.6, 8100 v2.4.1 Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 14x17 Size, e.g., 20 images (i.e., Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film

Page 205: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 206: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=10, TFT=u1_109b (i.e., mod.group=0) Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,10, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 8x10 Size, e.g., 6 images (i.e., Format=6:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film

Page 207: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 208: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

Esaote MR Artoscan/Escan via DICOM with| Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=5, TFT=Contrast Group=1 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=1024, Printer AE title=9410

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,5, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 8x10 Size, e.g., 6 images (i.e., Format=6:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film

Page 209: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=300, Contrast=5, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=5, Max.Density=300 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=11, Contrast=5, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 210: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k160, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=160

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 14x17 Size, eg 20 images (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear)

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 211: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Interpolation=Cubic, Image Polarity=Normal (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 212: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k2180, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=2180

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 14x17 Size, eg 20 images (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue)

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 213: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 214: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=k1120, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=1120

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=ANY n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=NORMAL, Border Density=BLACK n Empty img.density=BLACK, Max Density=300, Min Density=0 n Config.Information=CS435, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 14x17 Size, eg 20 images (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue)

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 215: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 216: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM 200 v6.1, DV8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMS Artoscan / Escan MR Setup: n in Menu: Help->Service->Option->DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8200

n in Help/Service/Option/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 14x17 Size, eg 20 images (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Blue

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 217: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

n Media Info: Media=35x35cm, 4361x4247, 4157, Blue n Media Info: Media=11x14in, 3272x4361, 4271, Blue n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On n Formatting: Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20 n Formatting: Max Img Col=0, Max Img Row=0, n Formatting: Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.1 n SCU: Density Space= On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at Keypad connected to MIM, press Menu, Service Menu, SCP Services: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 218: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3K Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8700

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: Film Size=14x17, eg Division=20 (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8700 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Page 219: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 220: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3K Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8500

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: Film Size=11x14, eg Division=20 (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set:

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8500 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Page 221: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 222: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8100

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: Film Size=14x17, eg Division=20 (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Kodak DryView 8100

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak MIM 200

Page 223: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES: TFT=ver693c0.w87 n on LOCAL PANEL: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 224: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Contrast=10, Modality Group=0 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

- Printer host name=dryview, Printer IP addr=accordingly - Printer TCP port=5040, Printer AE title=8300

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): - Film Orientation=PORTRAIT, Medium Type=BLUE FILM - Film Destination=PROCESSOR, Magnification Type=CUBIC - Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK - Max Density=300, Config.Information=LUT=0,10, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: Film Size=8x10, eg Division=6 (ie Format=6:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Kodak DryView 8300

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak MIM 200

Page 225: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N)

n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N)

n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1P n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 226: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

Esaote MR Artoscan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS compute Note: This setup is basically also valid for 8600 camera Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=5, TFT=Contrast Group=1 Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

- Printer host name=dryview, Printer IP addr=accordingly - Printer TCP port=5040, Printer AE title=8610

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): - Film Orientation=PORTRAIT, Medium Type=BLUE FILM - Film Destination=PROCESSOR, Magnification Type=CUBIC - Print Smoothing=0, Border Density=BLACK, Empty img.density=BLACK - Max Density=300, Config.Information=LUT=0,5, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: 8x10 Size, eg 6 images (ie Format=6:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Memory=32

Esaote MRUnix Solaris platform- Artoscan- Escan

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 227: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 55

n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line,Transfer=2000,Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=5 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=1 (Always=Y), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 228: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 56

Esaote MR Artoscan/Escan via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=8900

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: Film Size=14x17, eg Division=20 (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

Esaote MRUnix Solaris platform- Artoscan- Escan

DICOM Network

Kodak DryView 8900

Page 229: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 57

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsb.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always= N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=mr

Page 230: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 58

Esaote MR Artoscan/Escan via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

n Printer host name=dryview, Printer IP addr=accordingly n Printer TCP port=5040, Printer AE title=DV8150

n in Help/Service/Options/Printer Option set (writing parameters with capital letters !): n Film Orientation=PORTRAIT, Medium Type=BLUE FILM n Film Destination=PROCESSOR, Magnification Type=CUBIC n Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK n Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: Film Size=14x17, eg Division=20 (ie Format=20:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On

Esaote MRUnix Solaris platform- Artoscan- Escan

DICOM Network

Kodak DryView 8150

Page 231: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 59

n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mr

Page 232: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 60

Esaote MR Artoscan/Escan via DICOM with Kodak Color Medical Imager 1000

Requirements: Artoscan MR rel. 5.6A (build 6.1F), Escan MR rel. 1.1A (build 6.1F) Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: on MR only one DICOM camera could be defined Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3KB Artoscan / Escan MR Setup: n in Help/Service/Options/DICOM 3 Option set:

- Printer host name=CMI1000, Printer IP addr=accordingly - Printer TCP port=5040, Printer AE title=CMI1000

n in Help/Service/Options/Printer Option set (writing params with capital letters !): - Film Orientation=PORTRAIT, Medium Type=BLUE FILM - Film Destination=PROCESSOR, Magnification Type=CUBIC - Print Smoothing=2, Border Density=BLACK, Empty img.density=BLACK - Max Density=300, Config.Information=LUT=0,9, Trim=YES (is always yes)

n in Menu: Help->Print Layout set: Film Size=8x10, eg Division=6 (ie Format=6:1) n to acquire image on screen, press F6 or in Menu: Help->Print Layout set: Queue Image n automatic print after last F6 totally filled the film or in Help/Print Layout: Print Film CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP:

Esaote MRUnix Solaris platform- Artoscan- Escan

DICOM Network

Kodak CMI 1000

Page 233: Other OEM Setup Manuals

Esaote MR Artoscan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 61

n under Image Quality, Grayscale Image Quality: n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 234: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Esaote MR Artoscan-C/C-scan/Escan (WinNT platform) with LASER IMAGERS Connection POINT-TO-POINT (digital / keypad): n Kodak DryView 8700 LASER IMAGER / Plus

(see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 3 n Kodak DryView 8300 LASER IMAGER......................................................................... 4 n Kodak Digital Science 969 HQT LASER IMAGER ................................................... 5 n Kodak Digital Science 959 XL LASER IMAGER ...................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8700 Dual and HQ) (not tested yet, DICOM recommended)

n Kodak PACS LINK 9410 ACQUISITION SYSTEM / Kodak DryView 8100 LASER IMAGER (not tested yet, via DICOM recommended)

n Kodak DryView 8100 LASER IMAGER......................................................................... 7 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................. 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (4) . 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4).................................................................... 16 Connection POINT-TO-POINT (video / keypad): n Kodak DryView 8700 LASER IMAGER / Plus

(see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 18 n Kodak DryView 8100 LASER IMAGER......................................................................... 19

Page 235: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 20 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 21 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 22 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 24 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 26 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 28 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 30

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................ 32

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 34

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 36

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (3,4,5)............................................................... 38

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 40

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (4,5) ............ 42

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (4,5) ................................................................. 44

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (4,5) ................................................................. 46

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (4,5) .......................................................................................................... 48

n Kodak DryView 8900 LASER IMAGER......................................................................... 50 n Kodak DryView 8150 LASER IMAGER......................................................................... 52 n Kodak Color Medical Imager 1000 ................................................................................. 54

1 setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, 6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 236: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Artoscan-C/C-scan/Escan via digital/keypad with Kodak DryView 8700 LASER IMAGER / Plus

(see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

DEIB

Fiber Cable

Fiber Cable

UKEIB

Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8700 Plus3M8700 DryView

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B, 8700 v1.26 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor, press acquire button at camera keypad Note: in case the image quality matching between monitor and film is not ok, into 8700 IMAGE Menu set: TFT=C3b5ax4.w87,Dmax=280,Contrast =9 8700 Plus Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMSV3K, Dmax=3.00, C=9, D=14 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Pixel=8, Header/Line, Port=0, Parity=Disable, Timeout=10

Page 237: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Artoscan-C/C-scan/Escan via digital/keypad with Kodak DryView 8300 LASER IMAGER

Keypad

Digital Board Data outputData Cable 37-pin

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8300

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B, 8300 v4.9.1 Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor, press acquire button at camera keypad 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set:

n Serial Control Interface: Protocol=Keypad n Digital Interface: Parity=None, Modality Group=0

Page 238: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Artoscan-C/C-scan/Escan via digital/keypad with Kodak Digital Science 969 HQT LASER IMAGER

Keypad

Digital Board Data output

Data Cable 37-pin

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak M969 HQT

3 M H Q L a s e r I m a g e r

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B, 969 HQT v2.0 Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor, press acquire button at camera keypad M969 HQT Setup: n on TDB/C board: Jumpers=RS422, Switch=Left n on COMM Menu: 8700 Keypad Default n on IMAGE Menu: (note: values suitable for 60 secs chemistry)

n TFT=693C0, Contrast=6, Density=12, on OIC Menu: Chemistry=2 n on SYSTEM Menu: Memory Management=Best Fit n on EIB Menu: Pixel=8, Header/Line, Port=0, Parity=Disable, Timeout=10

Page 239: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Artoscan-C/C-scan/Escan via digital/keypad with Kodak Digital Science 959 XL LASER IMAGER

DEIB

Fiber Cable

Fiber Cable

Kodak M959 XL

UKEIB

XL Keypad

Digital Board Data output

Keypad

Data Cable 37-pin

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

3 M L a s e r I m a g e r

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B, 959 XL v3.8 Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor, press acquire button at camera keypad M959 XL Setup: n on XL Control Panel set Density & Contrast depending on chemistry n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center n on XL Input Module install LUT 322A0 n on COMM Menu: 959 Default n on EIB Menu: Pixel=8, Header/Line, Port=0, Parity=Disable, Timeout=10

Page 240: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Artoscan-C/C-scan/Escan via digital/keypad with Kodak DryView 8100 LASER IMAGER

Copper Cable

UKEIB

Keypad

Digital Board Data OUT

Keypad

Data Cable 37-pin

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8100

Imager

RS422 9-pole Plug

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B, 8100 v2.1.2 Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor, press acquire button at camera keypad Note: in case the image quality matching between monitor and film is not ok, into 8100 IMAGE QUALITY/TFT FILES set: TFT=C3b5ax4.w87 8100 LOCAL PANEL set: Dmax=280, Contrast =9 8100 Setup on CONFIGURATION Menu: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=10, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=2 n on IMAGE QUALITY-> TFT FILES Menu: TFT=PMSB n on LOCAL PANEL Menu: Contrast=9, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=8, Header/Line, Parity=Disable

Page 241: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Artoscan-C/C-scan/Escan via digital/keypad with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor,

press acquire button at camera keypad MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off

n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0

Data Cable 37-pin

Kodak MIM 200

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Digital BoardData OUT

Kodak 160 camera

RS422 37-to-50 pinDigital Adaptor Cable

CrossedNetwork Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 242: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup:

n Select Destination=KELI 160, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console=On

160 Setup: no modality-specific setup needed

Page 243: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Artoscan-C/C-scan/Escan via digital/keypad with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B Requirements: MIM 200 v6.1, KELP 2180 v2.17H Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor,

press acquire button at camera keypad MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0

Data Cable 37-pin

Kodak MIM 200

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Digital BoardData OUT

Kodak 2180 camera

RS422 37-to-50 pinDigital Adaptor Cable

Fiber Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 244: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELP 2180, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console= On

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 245: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Artoscan-C/C-scan/Escan via digital/keypad with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B Requirements: MIM 200 v6.1, KELP 1120 v2.40/032 Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor,

press acquire button at camera keypad MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0

Data Cable 37-pin

Kodak MIM 200

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Digital BoardData OUT

Kodak 1120 camera

RS422 37-to-50 pinDigital Adaptor Cable

Fiber Cable

Kpad / Host Control Octopus Adaptor Cable

Keypad

Page 246: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu:

n into Machine Setup Menu set: Tonescaling=CurveShape n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination=KELP 1120, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Film Contrast=+0, Interpolation=Cubic Spline n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n Curve Shape=3.0, Auto Study=Off, Console= On

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 247: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Artoscan-C/C-scan/Escan via digital/keypad with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM 200 Destinations Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor,

press acquire button at camera keypad Note: in case the image quality matching between monitor and film is not ok, into MIM Kpad, Menu, Imaging Options set: TFT=C3b5ax4.w87,Dmax=280,Contrast =9 MIM200 Setup: n on Configure, Network: n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Keypad

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

Fiber Cable

Fiber Cable

3M8700DryView

Kodak DryView 8700 Plus

RS422 37-to-50 pinDigital Adaptor Cable

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Digital BoardData OUT

Data Cable 37-pin

Page 248: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8700, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options:

n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Pmsv3k.w87, Auto Study=Off, Console=On, Annotation=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 249: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Artoscan-C/C-scan/Escan via digital/keypad with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B Requirements: MIM200 v6.1, 8100 v2.4.1 Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor,

press acquire button at camera keypad Note: in case the image quality matching between monitor and film is not ok, into MIM Kpad, Menu, Imaging Options set: TFT=C3b5ax4.w87,Dmax=280,Contrast =9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Config., Input, Direct Connect, Config.Add, Digital, Qual=Esaote Artoscan: n Board/Channel=Digital Board 1 Channel 1, Logical Name= esamr, n Primary Control Type= Conv.Kpad, Com Port=9 n Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=512, Lines=480, Parity=None, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

KeypadEsaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak MIM 200

Kpad / Host Control Octopus Adaptor Cable

COPCIL BoardCopper Cable

Control 9-pin

Data 37 pin

RS4229-pole Plug

Kodak DryView 8100

Digital BoardData OUT

Data Cable 37-pinRS422 37-to-50 pinDigital Adaptor Cable

Page 250: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup n Select Destination= 8100, Media Size Select=35x43 n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=2, Film Contrast=9 n Image Dmax=3.00, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= Pmsb.w87, Auto Study=Off, Console=On, Annotation=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 251: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Artoscan-C/C-scan/Escan via video/keypad with Kodak DryView 8700 LASER IMAGER / Plus

(see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

EVEIB with PLL

Fiber Cable

Fiber Cable

UKEIB

Keypad

Video OUT

Keypad

Video Cable

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8700 Plus3M 8700 DryView

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B, 8700 v1.34 Important: for this connection an Enhanced VEIB is required Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras Note: Image Data not lutted by MR, lutted by Camera To Print: Select an image on MR monitor, press print button at MR monitor, press acquire button at camera keypad 8700 Plus Setup: n on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center n on COMM Menu: 969 Default n on IMAGE Menu: TFT=PMSV3K, Dmax=3.00, C=9, D=14 n on SYSTEM Menu: Interface=Enhanced VEIB, Memory Management=Best Fit n on EIB Menu:

n Vert.Del.=78, Image Lines=512, Horiz.Del.=377, Horiz.Act.=510 n Clock Delay=9, Fine Pixel Delay=123, Black Level=232, Digital Gain=67 n Pixel Clock Freq.=100, Horiz.Freq.=32-64, Double Gain=0.5-1, Port=0 n Passes=32, Window Width=7, Retries=3, Video Input=Standard Video n Clock Range=>50, Clocks per Line=1682, Non-Interlaced, Odd n Advanced ?=No,Vert.Sync Det.=don’t care,Black Level W.=don’t care

Page 252: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Artoscan-C/C-scan/Escan via video/keypad with Kodak DryView 8100 LASER IMAGER

Requirements: Artoscan-C v7.1A, C-scan v7.1A, Escan v3.0, 8100 v2.4.1 Setup: on UKEIB set ON/OFF/ON/ON/ON/ON, Switch=Center 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=10, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=On, Pixel Correct=On, 952 Override=13 n on IMAGE QUALITY-> TFT FILES Menu: TFT=PMSB n on LOCAL PANEL Menu: Contrast=9, Density=3.00 n on SYSTEM Menu: Acquire=Video n on VIDEO Menu: Parameters as per autosync ie aprox:

n Horiz.Freq.=79999, Frame Period=14, Vert.Total=1066, PassMode=1 n Horiz.Total=1600, Phase Delay=30, Horiz.Back Porch=364 n Image Width=492, Vert.Back Porch=750, Image Height=520 n Horiz.Sync Width=937, InterlaceMode=0 ie No, Pixel Clock=0 ie No

Keypad

DryView 8100

Image Video OUT

RS422 9-poleplug

Video Cable

Imager

Keypad UKEIB 9-to-9-pinCopper Cable

Esaote MRWindows platform- Artoscan-C- C-scan- Escan

Page 253: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Artoscan-C/C-scan/Escan via DICOM with Kodak DryView 8300 LASER IMAGER

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8300

DICOM Network

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Contrast=10, Modality Group=0 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name=IP addr of 8300 n Port=104, Remote AE title=IMN_8300 n Printer=Kodak 8300 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 8x10 Size, set Format eg 6 images 2 x 3, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set:

n Modality Group=0

Page 254: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

Artoscan-C/C-scan/Escan via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

DICOM Network

Kodak 190 camera

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 190 rel. 1.7.29 Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=k190, Host Name=IP addr of 190 n Port=5040, Remote AE title=190 n Printer=Kodak 190 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=k190, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 255: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers and in case of HQ by installing 969 into MR DICOM Camera Config.File

Note: Image Data not lutted by MR, lutted by Camera in this case use Dmax=300, C=9, TFT=PMS

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into 9410/Device Setup/SCP Printers/Registered User set: TFT/ULUT=C3b5ax4.w87, Max.Density=280, Contrast Table=9 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name=IP addr of 9410 n Port=1024, Remote AE title=9410 n Printer=Kodak 8700 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None

Page 256: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 257: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMS MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of 9410 n Port=1024, Remote AE title= 9410 n Printer=Kodak 8500 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 11x14 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into 9410/Device Setup/SCP Printers/Registered User set: TFT/ULUT=C3b5ax4.w87, Max.Density=280, Contrast Table=9 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8500 Plus

Kodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Page 258: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 259: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 9410 v1.6, 8100 v2.4.1 Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB

MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name=IP addr of 9410 n Port=1024, Remote AE title=9410 n Printer=Kodak 8100 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into 9410/Device Setup/SCP Printers/Registered User set: TFT/ULUT=C3b5ax4.w87, Max.Density=280, Contrast Table=9 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers:

Page 260: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Printer=8100, AE Title=9410, Port=1024, Max Associations=5 on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 261: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B

Note: Image Data not lutted by MR, lutted by Camera in this case use Dmax=300, C=10, TFT=u1_109b (i.e., mod.group=0)

MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name=IP addr of 9410 n Port=1024, Remote AE title=9410 n Printer=Kodak 8300 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 8x10 Size, set Format eg 6 images 2 x 3, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Page 262: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 263: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=5, TFT=Contrast Group=1 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name=IP addr of 9410 n Port=1024, Remote AE title=9410 n Printer=Kodak 8600 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 8x10 Size, set Format eg 6 images 2 x 3, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=300, Contrast=5, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title=9410, Port=1024, Max Associations=5

Page 264: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=5, Max.Density=300 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 265: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM 200 v6.1, KELI 160 v7.2 Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=k160, Host Name= IP addr of MIM200 n Port=5040, Remote AE title=160 n Printer=Kodak 160 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=k160, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 266: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Interpolation=Cubic, Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 267: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=k2180, Host Name= IP addr of MIM200 n Port=5040, Remote AE title=2180 n Printer=Kodak 2180 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=k2180, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Esaote MR- Artoscan- Escan

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 268: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 269: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, Curve Shape=3.0, Film Contrast=0 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=k1120, Host Name= IP addr of MIM200 n Port=5040, Remote AE title=1120 n Printer=Kodak 1120 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=k1120, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 270: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 271: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM 200 v6.1, DV8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMS MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of MIM200 n Port=5040, Remote AE title=8200 n Printer=Kodak 8200 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into MIM200/SCP Services set: TFT/ULUT=C3b5ax4.w87, Image Dmax=280, Contrast =9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 272: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Blue n Media Info: Media=35x35cm, 4361x4247, 4157, Blue n Media Info: Media=11x14in, 3272x4361, 4271, Blue n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On n Formatting: Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20 n Formatting: Max Img Col=0, Max Img Row=0, n Formatting: Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.1 n SCU: Density Space= On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at Keypad connected to MIM, press Menu, Service Menu, SCP Services: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 273: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination and in case of HQ by installing 969 into MR DICOM Camera Config.File

Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMS MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of MIM200 n Port=5040, Remote AE title= 8700 n Printer=Kodak 8700 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into MIM200/SCP Services set: TFT/ULUT=C3b5ax4.w87, Image Dmax=280, Contrast =9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8700 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Page 274: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N)

n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 275: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMS MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of MIM200 n Port=5040, Remote AE title= 8500 n Printer=Kodak 8500 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 11x14 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into MIM200/SCP Services set: TFT/ULUT=C3b5ax4.w87, Image Dmax=280, Contrast =9 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8500 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Page 276: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 277: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM200 v6.1, 8100 v2.4.1 Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of MIM200 n Port=5040, Remote AE title= 8100 n Printer=Kodak 8100 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 14x17 Size, set Format eg 20 images 4 x 5, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into MIM200/SCP Services set: TFT/ULUT=C3b5ax4.w87, Image Dmax=280, Contrast =9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32

Kodak DryView 8100

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak MIM 200

Page 278: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 279: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=10, TFT= u1_109s (ie mod.group=0) MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of MIM200 n Port=5040, Remote AE title= 8300 n Printer=Kodak 8300 for MR printer profile

n To Print: open images on MR monitor and press Print Layout icon, under File/Print select Printers=DryView, set 8x10 Size, set Format eg 6 images 2 x 3, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On

Kodak DryView 8300

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak MIM 200

Page 280: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 281: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

Artoscan-C/C-scan/Escan via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=5, TFT=Contrast Group=1 MR Setup: n in Internet Explorer Menu: DICOM Config->Print->Add-> set: n Description=DryView, Host Name= IP addr of MIM200 n Port=5040, Remote AE title= 8610 n Printer=Kodak 8600 for MR printer profile n To Print: open images on MR monitor and press Print Layout icon,

under File/Print select Printers=DryView, set 8x10 Size, set Format eg 6 images 2 x 3, click on image to select it and press F9 to add it into film, press Print to send the Print Job to camera

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 282: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=upmsv3kp.w8u (Always=N), Contrast (dry)=5 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=mr n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 283: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

Artoscan-C/C-scan/Escan via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Artoscan-C v7.3BSP2, C-scan v7.3BSP2, Escan XQ v8.0A Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB MR Setup: n in Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of 8900 n Port=5040, Remote AE title= 8900 n Printer=eg Kodak 8200 for MR printer profile

n To Print: in Menu Print set 14x17 Size, eg 20 images (ie Format=20:1), Select images on MR monitor and press print button at MR monitor

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into 8900/Configuration/DICOM SCP/SCP Services set: TFT/ULUT=C3b5ax4.w87, Image Dmax=280, Contrast =9 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

DICOM Network

Kodak DryView 8900

Page 284: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsb.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always= N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=mr

Page 285: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

Artoscan-C/C-scan/Escan via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSB MR Setup: n in Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of 8150 n Port=5040, Remote AE title=DV8150 n Printer=eg Kodak 8200 for MR printer profile

n To Print: in Menu Print set 14x17 Size, eg 20 images (ie Format=20:1), Select images on MR monitor and press print button at MR monitor

Note: in case the image quality matching between monitor and film is not ok: - into MR DICOM Config/Print/Add set: Printer=Generic MR DICOM printer profile - into 8150/Configuration/DICOM SCP/SCP Services set: TFT/ULUT=C3b5ax4.w87, Image Dmax=280, Contrast =9 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

DICOM Network

Kodak DryView 8150

Page 286: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=mr

Page 287: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

Artoscan-C/C-scan/Escan via DICOM with Kodak Color Medical Imager 1000

Requirements: Artoscan-C v7.3B, C-scan v7.3B, Escan XQ v3.1B Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Image Data not lutted by MR, lutted by Camera

in this case use Dmax=300, C=9, TFT=PMSV3K MR Setup: n in Menu: DICOM Config->Print->Add-> set:

n Description=DryView, Host Name= IP addr of CMI1000 n Port=5040, Remote AE title=CMI1000 n Printer=Kodak CMI 1000 for MR printer profile

n To Print: in Menu Print set 8x10 Size, eg 6 images (ie Format=6:1), Select images on MR monitor and press print button at MR monitor

CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N)

Esaote MRWinNT platform- Artoscan-C- C-scan- Escan

DICOM Network

Kodak CMI 1000

Page 288: Other OEM Setup Manuals

Esaote MR Artoscan-C/C-scan/Escan with LASER IMAGER Products

Author: [email protected], Edition: May ´05 55

n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 289: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Esaote Ultrasounds with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 10 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 12

n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................................................ 15 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) .............................................................. 17 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) .............................................................. 19 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)............................................................... 21 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(4,5) 23 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (4,5) ............ 25 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5) ................................................................. 27 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5) ................................................................. 29 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (4,5) .......................................................................................................... 31

n Kodak DryView 8900 LASER IMAGER......................................................................... 33 n Kodak DryView 8150 LASER IMAGER......................................................................... 35 n Kodak Color Medical Imager 1000 ................................................................................. 37

1 setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 290: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Esaote US via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8300, Dicom Device=Kodak 8300,

AE Title=8300, IP addr=accordingly, Port=104 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8300 6:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=2,3 Size=8x10, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8300 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=8INx10IN, Orientation=Portrait,

Magnification=Cubic, Trim=No, Smoothing Type=2 Density max=260, Config.Info=LUT=1,2

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8300,

AE Title= 8300, IP addr=accordingly, Port=104 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8300, AE Title=8300, DICOM Printer Type=Kodak_8300 - IP addr=accordingly, Port=104, Enabled=On - select created printer and into Modify Layout check: Description=Format 6:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\2,3

Kodak DryView 8300

DICOM Network

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 291: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

- Orientation=Portrait, Film Size=8INx10IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8300, Page Layout=Format 6:1 - to print a film, select image at monitor, press button Print till layout completed 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=12, Contrast=2, Sharp/Smooth=2 n on 8300 Service Menu into Configure User set:

n Modality Group=1

Page 292: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Esaote US via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers and in case of HQ by choosing 969 into Esaote DICOM Camera Config.File

Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8700, Dicom Device=Kodak 8700,

AE Title= 9410, IP addr=accordingly, Port=1024 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8700 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8700 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsv3k.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8700,

AE Title= 9410, IP addr=accordingly, Port=1024 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup:

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 293: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

- into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8700, AE Title=9410, DICOM Printer Type=Kodak_8700 - IP addr=accordingly, Port=1024, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8700, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=5, TFT/ULUT=Pmsv3k.w87 n Max.Density=260, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 294: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Esaote US via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8500, Dicom Device=Kodak 8500,

AE Title= 9410, IP addr=accordingly, Port=1024 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8500 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=11x14, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8500 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=11INx14IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsv3k.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8500,

AE Title= 9410, IP addr=accordingly, Port=1024 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator

Kodak DryView 8500 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 295: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

- into Settings/DICOM Print/Add Printer set: - Description=8500, AE Title=9410, DICOM Printer Type=Kodak_8500 - IP addr=accordingly, Port=1024, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=11INx14IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8500, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=5, TFT/ULUT=Pmsv3k.w87 n Max.Density=260, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 296: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Esaote US via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 9410 v1.6, 8100 v2.4.1 Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8100, Dicom Device=Kodak 8100,

AE Title= 9410, IP addr=accordingly, Port=1024 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8100 20:1, Copies=1, Priority=Low Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8100 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsb.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8100,

AE Title= 9410, IP addr=accordingly, Port=1024 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8100, AE Title=9410, DICOM Printer Type=Kodak_8100 - IP addr=accordingly, Port=1024, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 297: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

- Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8100, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=5, TFT/ULUT=Pmsb.w87 n Max.Density=260, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 298: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Esaote US via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8300, Dicom Device=Kodak 8300,

AE Title= 9410, IP addr=accordingly, Port=1024 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8300 6:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=2,3 Size=8x10, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8300-9410-MIM200 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=8INx10IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT= upmsv3k.w8u,2

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8300,

AE Title= 9410, IP addr=accordingly, Port=1024 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8300, AE Title=9410 - DICOM Printer Type=Kodak_8300-9410-MIM200

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 299: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

- IP addr=accordingly, Port=1024, Enabled=On - select created printer and into Modify Layout check: Description=Format 6:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\2,3 - Orientation=Portrait, Film Size=8INx10IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8300, Page Layout=Format 6:1 - to print a film, select image at monitor, press button Print till layout completed 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8300, Model=8300 Copper, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type =831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=2, TFT/ULUT=upmsv3k.w8u n Max.Density=260, Border=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1:1 Portrait, 2:1P, 4:1P, 6:1 n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 300: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Esaote US via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8610, Dicom Device=Kodak 8610,

AE Title= 9410, IP addr=accordingly, Port=1024 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8610 6:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=2,3 Size=8x10, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8600-8610 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=8INx10IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=4, Density max=260, Config.Info=LUT=0,2

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8610,

AE Title=9410, IP addr=accordingly, Port=1024 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8610, AE Title=9410, DICOM Printer Type=Kodak_8600-8610

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 301: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

- IP addr=accordingly, Port=1024, Enabled=On - select created printer and into Modify Layout check: Description=Format 6:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\2,3 - Orientation=Portrait, Film Size=8INx10IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8610, Page Layout=Format 6:1 - to print a film, select image at monitor, press button Print till layout completed 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=260, Contrast=2, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title=9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=2, Max.Density=260 n Border Density=0, Mag.Type=8, Smoothing=4 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 302: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Esaote US via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 190 rel. 1.7.29 Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=190, Dicom Device=Kodak 190,

AE Title=190, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 190 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=clicked, Dmax=260

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 190 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Magazine, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnif.=Cubic, Trim=No, Smoothing Type=NORMAL, Border=Black, Empty=Black, Density max=260, Config.Info=CS435\CN0\PD1.2

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_190,

AE Title=190, IP addr=accordingly, Port=5040 - to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=190, AE Title=190, DICOM Printer Type=Kodak_190 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4

DICOM Network

Kodak 190 cameraEsaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 303: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

- Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=190, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=2.60, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 304: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, KELI 160 v7.2 Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=160, Dicom Device=Kodak 160,

AE Title=160, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 160 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=clicked, Dmax=260

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 160 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnif.=Cubic, Trim=No, Border=Black, Empty=Black Smoothing Type=NORMAL, Density max=260, Config.Info=CS435\CN0

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_160,

AE Title= 160, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=160, AE Title=160, DICOM Printer Type=Kodak_160 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak 160 cameraEsaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 305: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

- Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=160, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off 160 Setup: no modality-specific setup needed

Page 306: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, 2180 rel. 2.17H Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=2180, Dicom Device=Kodak 2180,

AE Title=2180, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 2180 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=clicked, Dmax=260

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 2180-1120 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnif.=Cubic, Trim=No, Border=Black, Empty=Black Smoothing Type= NORMAL, Density max=260, Config.Info=CS435\CN0

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_2180,

AE Title= 2180, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=2180, AE Title=2180, DICOM Printer Type=Kodak_2180-1120 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 cameraEsaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 307: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

- Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=2180, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off, Film Output Dest=Bin 9 (Always=N)

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 308: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=1120, Dicom Device=Kodak 1120,

AE Title=1120, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 1120 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=clicked, Dmax=260

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 2180-1120 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnif.=Cubic, Trim=No, Border=Black, Empty=Black Smoothing Type= NORMAL, Density max=260, Config.Info=CS435\CN0

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_1120,

AE Title=1120, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=1120, AE Title=1120, DICOM Printer Type=Kodak_2180-1120 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 cameraEsaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 309: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

- Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=1120, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 310: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, DV8200 v3.5 Note: This setup is basically also valid for 25 PS computer Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8200, Dicom Device=Kodak 8200,

AE Title=8200, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8200 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=clicked, Dmax=260

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8200 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsv3k.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8200,

AE Title=8200, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8200, AE Title=8200, DICOM Printer Type=Kodak_8200

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 311: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

- IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8200, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=5 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N)

Page 312: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 313: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination and in case of HQ by choosing 969 into Esaote DICOM Camera Config.File

Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8700, Dicom Device=Kodak 8700,

AE Title=8700, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8700 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8700 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsv3k.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8700,

AE Title=8700, IP addr=accordingly, Port=5040

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 314: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8700, AE Title=8700, DICOM Printer Type=Kodak_8700 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8700, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=5 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N)

Page 315: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 316: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8500, Dicom Device=Kodak 8500,

AE Title= 8500, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8500 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=11x14, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8500 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=11INx14IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsv3k.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8500,

AE Title= 8500, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup:

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 317: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

- into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8500, AE Title=8500, DICOM Printer Type=Kodak_8500 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=11INx14IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8500, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set:

n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=5 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N)

Page 318: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 319: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8100, Dicom Device=Kodak 8100,

AE Title= 8100, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8100 20:1, Copies=1, Priority=Low Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8100 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsb.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8100,

AE Title= 8100, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set:

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 320: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

- Description=8100, AE Title=8100, DICOM Printer Type=Kodak_8100 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8100, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=5 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N)

Page 321: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n Negotiate Color Print=Off 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 322: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8300, Dicom Device=Kodak 8300,

AE Title= 8300, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8300 6:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=2,3 Size=8x10, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8300-9410-MIM200 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=8INx10IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info= LUT=upmsv3k.w8u,2

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8300,

AE Title= 8300, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8300, AE Title=8300

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 323: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

- DICOM Printer Type=Kodak_8300-9410-MIM200 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 6:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\2,3 - Orientation=Portrait, Film Size=8INx10IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8300, Page Layout=Format 6:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3k.w8u (Always=N), Contrast (dry)=2 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N)

Page 324: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

n Negotiate Color Print=Off 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 325: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Esaote US via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=8610, Dicom Device=Kodak 8610,

AE Title=8610, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8610 6:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=2,3 Size=8x10, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak 8600-8610 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=8INx10IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=4, Density max=260, Config.Info=LUT=0,2

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8610,

AE Title=8610, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set:

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 326: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

- Description=8610, AE Title=8610, DICOM Printer Type=Kodak_8600-8610 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 6:1 - Copies=1, Medium Type=Blue Film, Display Format=STANDARD\2,3 - Orientation=Portrait, Film Size=8INx10IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8610, Page Layout=Format 6:1 - to print a film, select image at monitor, press button Print till layout completed MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60:

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=2 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=4 (Always=N), Border=3.99 (Always=N)

Page 327: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 328: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Esaote US via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set:Name=8900, Dicom Device=eg Kodak 8200,

AE Title=8900, IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8900 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=eg Kodak 8200 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsv3k.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8900,

AE Title=8900, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8900, AE Title=8900, DICOM Printer Type=Kodak_8900 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1

DICOM Network

Kodak DryView 8900

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 329: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

- Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8900, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=5 (Always=N) n Smoothing Type=2 (Always= N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=2.60 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=us

Page 330: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

Esaote US via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Esaote US AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set:Name=8150, Dicom Device=eg Kodak 8200,

AE Title=DV8150, IPaddr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak 8150 20:1, Copies=1, Priority=Low, Medium=Blue, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=4,5 Size=14x17, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Esaote US Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=eg Kodak 8200 - set into Session: Copies=1, Label=Printer Value, Medium=Blue Film,

Destination=Processor, Priority=High, Color print=Off - set into Film Box: Format=STANDARD\2,3, Film Size=14INx17IN,

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2, Density max=260, Config.Info=LUT=Pmsb.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_8150,

AE Title=DV8150, IP addr=accordingly, Port=5040 Esaote US Megas/Caris Plus/Esatune equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=8150, AE Title=DV8150, DICOM Printer Type=Kodak_8200 - IP addr=accordingly, Port=5040, Enabled=On - select created printer and into Modify Layout check: Description=Format 12:1

DICOM Network

Kodak DryView 8150

Esaote Ultrasounds- AU5-Technos-Megas / Caris Plus / Esatune

Page 331: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

- Copies=1, Medium Type=Blue Film, Display Format=STANDARD\3,4 - Orientation=Portrait, Film Size=14INx17IN, Color Capability=Grayscale - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=8150, Page Layout=Format 12:1 - to print a film, select image at monitor, press button Print till layout completed 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=5 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=2.60 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=us

Page 332: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

Esaote US via DICOM with Kodak Color Medical Imager 1000

Requirements: Esaote AU5 with ImageLab v7.0 Requirements: Esaote Technos with ImageLab v10.0 or v12.0 Requirements: Esaote Megas/Caris Plus/Esatune v5.01 with Dicom Gateway v4.0 Requirements: Esaote BioPACS v5.0 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) AU5 v7.0 Setup: - on Dicom Devices, Local Printer, set: Name=CMI10000, - Dicom Device=Kodak CMI1000 (or 8300), AE Title=CMI1000, - IP addr=accordingly, Port=5040 - on Dicom Device, Printer Setup, Select Layout:

Session: Name=Kodak CMI1000 6:1, Copies=1, Priority=Low, Medium=Paper, Destination=Processor

Page: Format=Standard, Orient=Portrait, Magnif=Cubic, Rows&Cols(C,R)=2,3 Size=8x10, Border=Black, Empty=Black, Max Density=not clicked

- to Print press mouse right button: Image->DICOM->Add to Print Layout Technos v10.0 or v12.0 Setup: - on Dicom/Configuration/Print/New choose Profile=Kodak CMI-1000 - set into Session: Copies=1, Label=Printer Value, Medium=Paper, Destination=Processor,

Priority=High, Color print=On (to be selected) - set into Film Box: Format=STANDARD\2,3, Film Size=A4 (or 8_5INx11IN),

Orientation=Portrait, Magnification=Cubic, Trim=No, Smoothing Type=2 Density max=260, Config.Info=Pmsv3k.w87,5

- set into Image Box: Polarity=Normal - set into Select Dicom Server: Name=Kodak_CMI-1000,

AE Title=CMI1000, IP addr=accordingly, Port=5040 Megas/Caris Plus/Esatune/BioPACS equipped with DICOM Gateway Setup: - into DICOM Gateway log as Administrator - into Settings/DICOM Print/Add Printer set: - Description=CMI1000, AE Title=CMI1000, - DICOM Printer Type=Kodak_CMI-1000 - IP addr=accordingly, Port=5040, Enabled=On

DICOM Network

Kodak CMI 1000

Esaote Ultrasounds- AU5- Technos- Megas / Caris Plus / Esatune- BioPACS

Page 333: Other OEM Setup Manuals

Esaote Ultrasounds with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

- select created printer and into Modify Layout check: Description=Format 6:1 - Copies=1, Medium Type=Paper, Display Format=STANDARD\2,3 - Orientation=Portrait, Film Size=A4 (or 8_5INx11IN), Color Capability=Color - into US Megas/Caris Plus/Esatune press button Menu - select Peripherals and press button Enter, select Printer and press button Enter, - for all US Applications ie Cardio, Vasc., Radio, OB, TCD, N.Head select - Gateway Printer=CMI1000, Page Layout=Format 6:1 - to print a film, select image at monitor, press button Print till layout completed CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=5 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 334: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Ferrania workstation RealViewer with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8100 LASER IMAGER......................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8300 LASER IMAGER......................................................................... 8

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) ................................................................................................................. 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER .......................................................................... 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (1).................................................................... 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) (1) ............................... 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 22

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 24

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 26

n Kodak DryView 8900 LASER IMAGER......................................................................... 28 n Kodak DryView 8150 LASER IMAGER......................................................................... 30 n Kodak Color Medical Imager 1000 ................................................................................. 32

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 335: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Ferrania RealViewer via DICOM with Kodak DryView 8300 LASER IMAGER

FerraniaRealViewer workstation

Kodak DryView 8300

DICOM Network

Requirements: Ferrania RealViewer v1.5, 8300 v4.9.1, 8300 DICOM board v3.3 Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size i.e., 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status i.e., does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Printer Name=DV8300, IPAddr=accordingly, Port=104, AEtitle=8300 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=8INX10IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,10, Smoothing=0, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=0 i.e., Auto n on 8300 Service Menu into Configure User set:

n Modality Group=0

Page 336: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Ferrania RealViewer via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Ferrania RealViewer workstation

DICOM Network

Kodak 190 camera

Requirements: Ferrania RealViewer rel.1.5, 190 rel. 1.7.29 Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size i.e., 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status i.e., does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Printer Name=K190, IPAddr=accordingly, Port=5040, AEtitle=190 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Smoothing=NORMAL n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 337: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Ferrania RealViewer via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Ferrania RealViewer workstation

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryViewFiber Cable

Fiber Cable

Requirements: Ferrania RealViewer v1.5, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers and in case of 8500 by setting into Ferrania RealViewer the parameter Film Size=11INX14IN

Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size i.e., 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status i.e., does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8700, IPAddr=accordingly, Port=1024, AEtitle=9410 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters

Page 338: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 339: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Ferrania RealViewer via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Ferrania RealViewer workstation

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Ferrania RealViewer v1.5, 9410 v1.6, 8100 v2.4.1 Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size i.e., 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status i.e., does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8100, IPAddr=accordingly, Port=1024, AEtitle=9410 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters

Page 340: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

9410 Setup: on Device Setup, LOCAL PRINTERS:

n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 341: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Ferrania RealViewer via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Ferrania RealViewer workstation

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL boardCopper Cable

Requirements: Ferrania RealViewer v1.5, 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size i.e., 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status i.e., does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8300, IPAddr=accordingly, Port=1024, AEtitle=9410 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=8INX10IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,10, Smoothing=0, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters

Page 342: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 343: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Ferrania RealViewer via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Ferrania RealViewer workstation

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Ferrania RealViewer v1.5, 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size i.e., 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status i.e., does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8610, IPAddr=accordingly, Port=1024, AEtitle=9410 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=8INX10IN , n set: Magnif=CUBIC, Max Density=350, Config.Info=LUT=0,5, Smoothing=1, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters

Page 344: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=300, Contrast=5, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title=9410, Port=1024, Max Associations=5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=5, Max.Density=300 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 345: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Ferrania RealViewer rel.1.5, MIM200 v6.1, KELI 160 v7.2 Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Printer Name=K160, IPAddr=accordingly, Port=5040, AEtitle=160 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Smoothing= NORMAL n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160

Ferrania RealViewer workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 346: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Interpolation=Cubic, Image Polarity=Normal (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 347: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Ferrania RealViewer v1.5, MIM200 v6.1, 2180 v2.17H Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Printer Name=K2180, IPAddr=accordingly, Port=5040, AEtitle=2180 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Smoothing= NORMAL n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly

Ferrania RealViewer workstation

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 348: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 349: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Ferrania RealViewer rel.1.5, MIM200 v6.1, 1120 v2.40/032 Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Printer Name=K1120, IPAddr=accordingly, Port=5040, AEtitle=1120 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Smoothing= NORMAL n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue)

Ferrania RealViewer workstation

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 350: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 351: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Ferrania RealViewer rel.1.5, MIM 200 v6.1, DV8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Printer Name=DV8200, IPAddr=accordingly, Port=5040, AEtitle=8200 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40,

Ferrania RealViewer workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 352: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Blue n Media Info: Media=35x35cm, 4361x4247, 4157, Blue n Media Info: Media=11x14in, 3272x4361, 4271, Blue n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On n Formatting: Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20 n Formatting: Max Img Col=0, Max Img Row=0, n Formatting: Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.1 n SCU: Density Space= On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at Keypad connected to MIM, press Menu, Service Menu, SCP Services: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 353: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Ferrania RealViewer v1.5 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination and in case of 8500 by setting into Ferrania RealViewer the parameter Film Size=11INX14IN

Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8700, IPAddr=accordingly, Port=5040, AEtitle=8700 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network:

Ferrania RealViewer workstation

Kodak DryView 8700 PlusDICOM Network

3M8700 DryViewFiber Cable

Fiber Cable

Kodak MIM 200

Page 354: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 355: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Ferrania RealViewer v1.5 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8100, IPAddr=accordingly, Port=5040, AEtitle=8100 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100

Kodak DryView 8100

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Ferrania RealViewer workstation

Kodak MIM 200

Page 356: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 357: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Ferrania RealViewer v1.5 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8300, IPAddr=accordingly, Port=5040, AEtitle=8300 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=8INX10IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,10, Smoothing=0, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300

Kodak DryView 8300

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Ferrania RealViewer workstation

Kodak MIM 200

Page 358: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 359: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Ferrania RealViewer via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Ferrania RealViewer v1.5 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8610, IPAddr=accordingly, Port=5040, AEtitle=8610 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=8INX10IN , n set: Magnif=CUBIC, Max Density=350, Config.Info=LUT=0,5, Smoothing=1, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Ferrania RealViewer workstation

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 360: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=upmsv3kp.w8u (Always=N), Contrast (dry)=5 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=mr n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.3, Contrast=6.P.1, Conv.Kernel=M.1.0 n (if 8600: Imager=2.4, Contrast=6.G.5B, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 361: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Ferrania RealViewer via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Ferrania RealViewer v1.5 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set:Remote Printers Name=DV8900,IPAddr=accordingly,Port=5040,AEtitle=8900 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any

Ferrania RealViewer workstation

DICOM Network

Kodak DryView 8900

Page 362: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsb.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always= N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 363: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

Ferrania RealViewer via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Ferrania RealViewer v1.5 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=DV8150, IPAddr=accordingly, Port=5040, AEtitle=DV8150 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=14INX17IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any

Ferrania RealViewer workstation

DICOM Network

Kodak DryView 8150

Page 364: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 365: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Ferrania RealViewer via DICOM with Kodak Color Medical Imager 1000

Requirements: Ferrania RealViewer v1.5 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Ferrania RealViewer workstation sends to camera what displayed on monitor. Max Ferrania image size is therefore max Ferrania monitor size ie 1k x 1.5k Note: to change format on Ferrania monitor uses CT/MRI Matrix button.

Possible Ferrania monitor formats: 1x1, 2x2, 3x2, 3x3, 4x3, 4x4, 5x4 Note: Ferrania Landscape is not functioning, Ferrania sends out only 8 bit images Note: Ferrania does not check the printer status ie does not send any Printer N-Get Ferrania RealViewer Setup: n into menu Preferences/Printers/Add: n set: Remote Printers Name=CMI1000, IPAddr=accordingly, Port=5040,

AEtitle=CMI1000 n into menu Print / DICOM Print Parameters / Basic Film Session SOP Class: n set: Copies=1, Priority=LOW, Medium=BLUE FILM, Destination=PROCESSOR n into menu Print / DICOM Print Parameters / Basic Film Box SOP Class: n set: Format=STANDARD\1,1, Orient=PORTRAIT, Film Size=8INX10IN , n set: Magnif=CUBIC, Max Density=300, Config.Info=LUT=0,9, Smoothing=2, n set: Border=BLACK, Empty Image=BLACK, Trim=NO n into menu Print / DICOM Print Parameters / Grayscale Image Box SOP Class: n set: Position=1, Polarity=NORMAL n note: click Send to Printer for all above selected parameters CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP

Ferrania RealViewer workstation

DICOM Network

Kodak CMI 1000

Page 366: Other OEM Setup Manuals

Ferrania workstation RealViewer with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n under Image Quality, Color Image Quality: (no need to adjust, leave defaults) n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 367: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 1

Specific Setup for GE Instrumentarium Dental Systems (new platform) OP100 D/OC100 D/Sigma with LASER IMAGERS OEM Data Manufacturer GE Modality Dental Systems Model OP100 D / OC100 D / Sigma sw version v6.0.0.27 Implement. Class UID 1.2.840.113999.42.6.0 Implement. Version Name CV_SC_100 Kodak Data DICOM-interface MIM internal / external as below reported DICOM-intf sw version as below reported Printer model All cameras as below reported Printer sw version as below reported What’s new: The setup of a Kodak printer for a given OEM Modality was split in 2 separate documents: - the generic Setup Catalog for Kodak Cameras - the specific Setup Manual for a given OEM Modality

************* the generic Setup Catalog for Kodak Cameras: the Setup Catalog for Kodak Cameras contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Setup Catalog for Kodak Cameras

(ie go to the Setup Catalog doc and do that first, then come back here and finish install as per this Specific Setup Manual doc). ************ the specific Setup Manual for a given OEM Modality: the Setup Manual for a given OEM Modality contains that part of a printer installation which is Specific to that particular OEM Modality to be connected, ie the OEM console Settings and the printer Image Quality parameters. Therefore, as second and final step, setup the printer as per the indications reported here into the Setup Manual for that particular OEM Modality. Note that the Setup Manual has 2 sections ie the DryView section and the Wet section.

Page 368: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 2

What’s inside this document: n OEM Modality Setup (ie how to configure,into the OEM console,the Kodak printer) 2 n DryView correspondance with Kodak Setup Catalog for DryView cameras................ 3 n Image Quality setup into MIM (or 9410) for DryView cameras ............................... 4 n More info on OEM Modality when connected to DryView cameras .............................. 5 n Wet correspondance with Kodak Setup Catalog for Wet cameras .................................. 6 n Image Quality setup into MIM (or 190) for Wet cameras ............................................... 7 n More info on OEM Modality eg Page-Mode and IQ parameters sent out by OEM ........ 8 n Miscellaneous: Deviations from Kodak Setup Catalog / Known Problems / Notes........ 9 OEM Modality Setup ie how to configure into the OEM console the Kodak printer: CliniView v6.0 Setup: - into Tools/DICOM settings/Print/Add new/ set: Printer Name=DryView, AE Title=8700, IP address=accordingly, Port=5040, Basic Grayscale Print Management=On, Basic Color Print Management=Off, (if CMI1000 Basic Grayscale Print Mng.=Off, Basic Color Print Mng.=On) Click OK For the just defined camera, select each parameter and click Edit to modify it as: Name=Image Display Format, Type=Replace if empty, Default value=1 Name=Annotation Display Format, Type=Replace if empty, Default value= Name=Film Orientation, Type=Replace if empty, Default value=PORTRAIT Name=Film Size ID, Type=Always default, Default value=14INX17IN Name=Magnification Type, Type=Replace if empty, Default value=CUBIC Name=Smoothing Type, Type=Replace if empty, Default value=11 Name=Border Density, Type=Always default, Default value=BLACK Name=Empty Image Density, Type=Always default, Default value=BLACK Name=Min Density, Type=Always default, Default value=0 Name=Max Density, Type=Replace if empty, Default value=300 Name=Trim, Type=Replace if empty, Default value=NO Name=Config.Info, Type=Replace if empty, Default value=LUT=Pmsv3k.w87,9 Name=Copies, Type=Replace if empty, Default value=1 Name=Print Priority, Type=Replace if empty, Default value=HIGH Name=Medium Type, Type=Replace if empty, Default value=BLUE FILM Name=Film Destination, Type=Always default, Default value=PROCESSOR Name=Film Session Label, Type=Replace if empty, Default value= Name=Memory Allocation, Type=Replace if empty, Default value= Name=Owner ID, Type=Replace if empty, Default value= Note: some parameters are only for Color Image Box, do not select Name=Samples per Pixel (Image Box), Type=Always default, Default value=1 Name=Photo Interpr., Type=Always default, Default value=MONOCHROME2 Name=Rows, Type=Always default, Default value=1024 Name=Columns, Type=Always default, Default value=1024 Name=Pixel Aspect Ratio, Type=Always default, Default value=1\1

Page 369: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 3

Name=Bits Allocated, Type=Always default, Default value=8 Name=Bits Stored, Type=Always default, Default value=8 Name=High Bit, Type=Always default, Default value=7 Name=Pixel Representation, Type=Always default, Default value=0 Name=Magnification Type, Type=Replace if empty, Default value=CUBIC Name=Smoothing Type, Type=Replace if empty, Default value=11 Name=Config.Info, Type=Replace if empty, Default value=LUT=Pmsv3k.w87,9 Name=Image Position, Type=Replace if empty, Default value=0 Name=Polarity, Type=Always default, Default value=NORMAL Name=RequestedImageSize, Type=Replace if empty, Default value= Name=Requested Dec/Crop Behavior, Type=Replace if empty, Default value= To print an image click on printer icon or select DICOM/Print to enter Print Editor, Select either the Free Layout (for free composition) or Grid Mode (ie usual formats), check mark the images that you want to print, if you want to print in True Size select Grid Mode, only 1 Grid, Scale 1:1, click on Page Setup icon and select Size=14 x 17 inches, Type=Blue Film, Orientation=Portrait, Copies=1, select File/Print and select on which camera to print the images

Page 370: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 4

DryView section: Setup for Kodak DryView cameras ie 8900, 8700, 8610, 8600, 8500, 8300, 8200, 8150, 8100, 1000 Correspondance with Kodak Setup Catalog for DryView cameras: Note: the Kodak Setup Catalog contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Kodak Setup Catalog, and then, as second and final step, setup the Image Quality parameters as per the Setup Manual for the Specific OEM Modality here below reported. MIM (inside printer) 8900 8150 into Kodak catalog see Setup as per page

19 20

MIM sw version 5.6.b5 5.7.b8 Printer sw version Rev.E ie 2.11 1.0.2.b04 MIM external 8700, 8500 8100 8300 8610 (8600) 8200 1000 into Kodak catalog see Setup as per page

15 16 17 18 14 21

MIM sw version 6.1 6.1 6.1 6.1 6.1 2.0.b3 Printer sw version 1.34 2.4.1 3.5 2.4 (2.5) 4.9.1 1.0.b8

Page 371: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 5

Image Quality setup into MIM for DryView cameras: MIM (or 9410) Parameters

8900, 8150, 8700, 8500, 8200, 8100,

1000 (see Note1 below)

8300 (see Note2 below,

confirm Y/N)

8610, 8600

TFT/ULUT (8610 Modality/Contrast Group) (Always Apply=Y/N)

Pmsv3k.w87

(Y)

u1_109s.w8u

(Y)

(gsdfaa0p.w8u) 6

Contrast (Always Apply=Y/N)

9 (Y)

10 (Y)

3 (Y)

Max.Density (Always Apply=Y/N)

300 (Y)

300 (Y)

350 (Y)

Smoothing (Always Apply=Y/N)

11 (Y)

2 (Y)

1 (Y)

Presentation ie PLUT=Y/N (not available on 9410)

N N N

8610 Convolution / Kernel Group Not available Not available 1 8610 Gamma Table Not available Not available Transmittance Note1: in particular for 8100, 8200, 8150 use TFT=Pmsb.w87.

Page 372: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 6

More info on OEM Modality when connected to DryView cameras:

Works the OEM Modality in Page-Mode? (Yes/No) No Note: see Page-Mode definition and matrixes into Kodak cameras setup catalog. Are Image Data lutted by the OEM Modality, ie Linear-in-Density LUT into Camera? (Yes/No)

No

Note: Linea-in-Density LUT into Camera means eg TFT=Wrkstn2a.w87, Dmax=3.00, C=2. Which are the Image Quality parameters sent out by the OEM Modality: DICOM Parameters

Sent out by Modality (Yes/No)

Value sent out for 8900, 8150, 8700, 8500, 8200, 8100,

1000

Value sent out for 8300

Value sent out for 8610, 8600

Config. Information (LUT=TFT,Contrast)

Yes

LUT=0,9

LUT=0,10

LUT=0,3

Max. Density Yes 300 300 300 Magnification Yes CUBIC CUBIC CUBIC Smoothing Yes 11 2 1 PLUT No Illumination (PLUT) No Reflective Ambient Light (PLUT)

No

Page 373: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 7

Wet section: Setup for Kodak Wet cameras ie 160, 2180, 1120, 190 Correspondance with Kodak Setup Catalog for Wet cameras: Note: the Kodak Setup Catalog contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Kodak Setup Catalog, and then, as second and final step, setup the Image Quality parameters as per the Setup Manual for the Specific OEM Modality here below reported. 160 2180 1120 190 into Kodak catalog see Setup as per page

11 12 13 6

MIM sw version 6.1 6.1 6.1 Not present Printer sw version 7.2 2.17H 2.40 / 032 1.7.29 Note: in regards to 969 parameters use the same as per 8700 setup.

Page 374: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 8

Image Quality setup into MIM (or 190) for Wet cameras: MIM (or 190) Parameters 160, 2180, 1120, 190

(see Note below) Curve Shape (Always Apply=Y/N)

3 (Y)

Contrast (Always Apply=Y/N)

0 (Y)

Max.Density (Always Apply=Y/N)

300 (Y)

PLUT=Y/N (not available on 190)

N

Note: reported setup was tested eg for 160 and tentatively is valid also for other cameras ie 2180, 1120, 190.

Page 375: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 9

More info on OEM Modality when connected to Wet cameras: Works the OEM Modality in Page-Mode? (Yes/No) No Note: see Page-Mode definition and matrixes into Kodak cameras setup catalog. Are Image Data lutted by the OEM Modality, ie Linear-in-Density LUT into Camera? (Yes/No)

No

Note: Linea-in-Density LUT into Camera means eg CurveShape=0,Dmax=3.00,Contrast=0. Which are the Image Quality parameters sent out by the OEM Modality: DICOM Parameters

Sent out by Modality (Yes/No)

Value sent out for 160, 2180, 1120,

190 Config. Information (CurveShape\Contrast)

Yes

CS435\CN0

Max. Density Yes 300 Magnification Yes CUBIC Smoothing No PLUT No Illumination (PLUT) No Reflective Ambient Light (PLUT)

No

Page 376: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 10

Miscellaneous: Deviations in respect to the printer setup reported into Kodak Catalog: e.g. disable N-Event ie NeventReports=No (Always=Y) Known Problems or Limitations: The new CliniView v6.0 platform does not work with 9410 platform and with 8300 standalone ie without MIM or 9410 in front Notes:

Page 377: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for GE Instrumentarium Dental Systems (old platform) OP100 D/OC100 D/Sigma with LASER IMAGERS Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 5 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER......................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER......................................................................... 11 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) ................................................................................................................. 14

n Kodak DryView 8300 LASER IMAGER (incompatibility with Instrumentarium Software, does not work)

n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 17 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 19 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 22 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 25 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 28 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 31 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 34 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 37 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 40

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (1).................................................................... 43

n Kodak DryView 8900 LASER IMAGER......................................................................... 46 n Kodak DryView 8150 LASER IMAGER......................................................................... 49 n Kodak Color Medical Imager 1000 ................................................................................. 52

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 378: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Page 379: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8700) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None

Page 380: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 381: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 11INX14IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Page 382: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

# Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\ Instrumentarium Imaging\ CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8500) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz

Page 383: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 384: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8100 v2.4.1 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\ Instrumentarium Imaging\CliniView \Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 385: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\ Instrumentarium Imaging\CliniView \Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\ Instrumentarium Imaging\ CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\ Instrumentarium Imaging\ CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\ WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8100) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0

Page 386: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 387: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,10 # Smoothing Type ; 6 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 388: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8300) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

Page 389: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=6 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 390: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ;LUT=0,3 # Smoothing Type ; 4 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 391: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8610) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: on SCP PRINTER Menu, Current Provider, SCP Parameters:

n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=3 n Max.Density=350, Border=0, Mag.Type=8, Smoothing=4 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low

Page 392: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

n Gamma Table=Linear in Transmittance, Contrast Group=6 n Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n D=16, C=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector = don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 393: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 190 rel. 1.7.29 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak 190 camera

Page 394: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

# Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 190) # Remote Print Host ; 190 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [190] (note: use here the same AE Title of the 190 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 190 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=190 DX2=PRINT_SCP IO1=190 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 190) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 395: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 396: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 2180 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [2180] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=2180 DX2=PRINT_SCP IO1=2180 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 2180) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180

Page 397: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 398: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 399: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 1120 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [1120] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=1120 DX2=PRINT_SCP IO1=1120 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 1120) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120

Page 400: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 401: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, KELI 160 v7.2 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 402: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 160 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [160] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=160 DX2=PRINT_SCP IO1=160 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 160) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30,

Page 403: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 404: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 405: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8700 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8700] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8700 DX2=PRINT_SCP IO1=8700 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8700) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Page 406: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 407: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 11INX14IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 408: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8500 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8500] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8500 DX2=PRINT_SCP IO1=8500 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8500) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Page 409: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 410: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 411: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

# Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8100 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8100] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8100 DX2=PRINT_SCP IO1=8100 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8100) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Page 412: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 413: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,10 # Smoothing Type ; 6 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 414: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8300 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8300] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8300 DX2=PRINT_SCP IO1=8300 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8300) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

Page 415: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On,Slide=On,Row Symmetric=On,SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=6 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 416: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ;LUT=0,3 # Smoothing Type ; 4 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 417: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8610 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8610] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8610 DX2=PRINT_SCP IO1=8610 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8610) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Mem=32

Page 418: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000,Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= gsdfaa0p.w8u (Always=N), Contrast (dry)=3 (Always=N) n Modality Group=6, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing=4 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=instr n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 419: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 420: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8200 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8200] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8200 DX2=PRINT_SCP IO1=8200 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8200) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32

Page 421: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 422: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak DryView 8900

Page 423: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 8900) # Remote Print Host ; 8900 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8900] (note: use here the same AE Title of the 8900 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 8900 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8900 DX2=PRINT_SCP IO1=8900 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8900) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any

Page 424: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 425: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak DryView 8150

Page 426: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 8150) # Remote Print Host ; DV8150 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [DV8150] (note: use here the same AE Title of the 8150 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 8150 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=DV8150 DX2=PRINT_SCP IO1=DV8150 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8150) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any

Page 427: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=11 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 428: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak Color Medical Imager 1000

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak CMI 1000

Page 429: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

# Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the CMI1000) # Remote Print Host ; CMI1000 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [CMI1000] (note: use here the same AE Title of the CMI1000 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of CMI1000 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=CMI1000 DX2=PRINT_SCP IO1=CMI1000 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg CMI1000) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP

Page 430: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

n under Image Quality, Color Image Quality: (no need to adjust, leave defaults) n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=11 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 431: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for GE Instrumentarium Dental Systems (old platform) OP100 D/OC100 D/Sigma with LASER IMAGERS Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 5 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER......................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER......................................................................... 11 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) ................................................................................................................. 14

n Kodak DryView 8300 LASER IMAGER (incompatibility with Instrumentarium Software, does not work)

n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 17 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 19 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 22 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 25 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 28 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 31 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 34 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 37 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 40

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (1).................................................................... 43

n Kodak DryView 8900 LASER IMAGER......................................................................... 46 n Kodak DryView 8150 LASER IMAGER......................................................................... 49 n Kodak Color Medical Imager 1000 ................................................................................. 52

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 432: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Page 433: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8700) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None

Page 434: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 435: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 11INX14IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Page 436: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

# Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\ Instrumentarium Imaging\ CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8500) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz

Page 437: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 438: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8100 v2.4.1 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\ Instrumentarium Imaging\CliniView \Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 439: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\ Instrumentarium Imaging\CliniView \Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\ Instrumentarium Imaging\ CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\ Instrumentarium Imaging\ CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\ WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8100) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0

Page 440: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 441: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,10 # Smoothing Type ; 6 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 442: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8300) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

Page 443: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=6 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 444: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ;LUT=0,3 # Smoothing Type ; 4 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 445: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [9410] (note: use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=9410 DX2=PRINT_SCP IO1=9410 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8610) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

9410 Setup: on SCP PRINTER Menu, Current Provider, SCP Parameters:

n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=3 n Max.Density=350, Border=0, Mag.Type=8, Smoothing=4 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low

Page 446: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

n Gamma Table=Linear in Transmittance, Contrast Group=6 n Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n D=16, C=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector = don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 447: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 190 rel. 1.7.29 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak 190 camera

Page 448: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

# Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 190) # Remote Print Host ; 190 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [190] (note: use here the same AE Title of the 190 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 190 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=190 DX2=PRINT_SCP IO1=190 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 190) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 449: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 450: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 2180 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [2180] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=2180 DX2=PRINT_SCP IO1=2180 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 2180) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180

Page 451: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 452: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 453: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 1120 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [1120] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=1120 DX2=PRINT_SCP IO1=1120 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 1120) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120

Page 454: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 455: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, KELI 160 v7.2 Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 456: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 160 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [160] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=160 DX2=PRINT_SCP IO1=160 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 160) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30,

Page 457: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 458: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 459: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8700 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8700] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8700 DX2=PRINT_SCP IO1=8700 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8700) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Page 460: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 461: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 11INX14IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 462: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8500 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8500] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8500 DX2=PRINT_SCP IO1=8500 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8500) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

Page 463: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 464: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 465: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

# Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8100 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8100] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8100 DX2=PRINT_SCP IO1=8100 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8100) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Page 466: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 467: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,10 # Smoothing Type ; 6 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 468: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8300 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8300] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8300 DX2=PRINT_SCP IO1=8300 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8300) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

Page 469: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On,Slide=On,Row Symmetric=On,SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=6 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 470: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ;LUT=0,3 # Smoothing Type ; 4 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 471: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8610 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8610] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8610 DX2=PRINT_SCP IO1=8610 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8610) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Mem=32

Page 472: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000,Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= gsdfaa0p.w8u (Always=N), Contrast (dry)=3 (Always=N) n Modality Group=6, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing=4 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=instr n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 473: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ;LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 474: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the MIM200) # Remote Print Host ; 8200 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8200] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8200 DX2=PRINT_SCP IO1=8200 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8200) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32

Page 475: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 476: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak DryView 8900

Page 477: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 8900) # Remote Print Host ; 8900 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [8900] (note: use here the same AE Title of the 8900 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 8900 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=8900 DX2=PRINT_SCP IO1=8900 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8900) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies

8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any

Page 478: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 479: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak DryView 8150

Page 480: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the 8150) # Remote Print Host ; DV8150 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [DV8150] (note: use here the same AE Title of the 8150 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 8150 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=DV8150 DX2=PRINT_SCP IO1=DV8150 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg 8150) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any

Page 481: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=11 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 482: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

Instrumentarium OP100 D/OC100 D/Sigma via DICOM with Kodak Color Medical Imager 1000

Requirements: Instrumentarium Cliniview platform v3.3.19 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: on Instrumentarium in general only 2 DICOM printers could be installed Instrumentarium Setup: - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1

Instrumentariumdental systems:- Orthopantomograph OP100 D- Orthoceph OC100 D- Sigma detectors

DICOM Network

Kodak CMI 1000

Page 483: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

# Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\Instrumentarium Imaging\CliniView\Config.CFG set: Association Attributes (note: set here the AE Title of the CMI1000) # Remote Print Host ; CMI1000 - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.APP set: [CMI1000] (note: use here the same AE Title of the CMI1000 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of CMI1000 SERVICE_LIST= Print_Service_List - into file C:\Instrumentarium Imaging\CliniView\mergeini\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 - into file C:\WinNT\CliniView.ini set: [DicomPrintAE] DXCount=2 DXDefault=1 IOCount=2 IODefault=1 DX1=CMI1000 DX2=PRINT_SCP IO1=CMI1000 IO2=PRINT_SCP Note: on Instrumentarium application to print select image, select File\DICOM\Print and choose following parameters and press Print: - printer on which to print images (eg CMI1000) - Portrait or Landscape - Film Layout ie nbr of columns x nbr of rows - Nbr of Copies CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP

Page 484: Other OEM Setup Manuals

GE Instrumentarium Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 54

n under Image Quality, Color Image Quality: (no need to adjust, leave defaults) n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=11 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 485: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for GE Instrumentarium Mammography Diamond with LASER IMAGERS Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) ..... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1) .................. 5 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1) ..................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1) ..................................................................... 11 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................. 14

n Kodak DryView 8300 LASER IMAGER (incompatibility with Instrumentarium Software, does not work)

n Kodak Digital Science 190 MEDICAL LASER PRINTER........................................... 17 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2)................................................................... 19 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2)................................................................... 22 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2) ...................................................................... 25 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(2,3).... 28 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (2,3) ................ 31 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (2,3)................................................................... 34 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (2,3)................................................................... 37 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (2,3)........................................................................................................... 40

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (2,3)................................................................... 43

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 46 n Kodak DryView 8150 LASER IMAGER.......................................................................... 49

1 setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.5.1. 2 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 3 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 486: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

Diamond via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Delta 32 vl.3.1 Requirements: 9410 v1.6, 8700 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

KodakDryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 487: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\D32Tact\system\Mergecom.APP set: [9410] (note : use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5

Page 488: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 489: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

Diamond via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Delta 32 vl.3.1 Requirements: 9410 v1.6, 8500 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 11INX14IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

KodakDryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 490: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\D32Tact\system\Mergecom.APP set: [9410] (note : use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port= 1024, Max Associations= 5

Page 491: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 492: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

Diamond via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Delta 32 vl.3.1 Requirements: 9410 v1.6, 8100 v2.4.1 Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 493: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

# Sample Per Pixel ; 1 # Photometric Interpretation ; MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\D32Tact\system\Mergecom.APP set: [9410] (note : use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly

Page 494: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 495: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

Diamond via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Delta 32 vl.3.1 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,10 # Smoothing Type ; 6 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 496: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\D32Tact\system\Mergecom.APP set: [9410] (note : use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u

Page 497: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 13

n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=6 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 498: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 14

Diamond via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Delta 32 vl.3.1 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ; LUT=0,3 # Smoothing Type ; 4 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 499: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 15

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 9410) # Remote Print Host ; 9410 - into file C:\D32Tact\system\Mergecom.APP set: [9410] (note : use here the same AE Title of the 9410 as just above) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=1024 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 9410 Setup: on SCP PRINTER Menu, Current Provider, SCP Parameters:

n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=3 n Max.Density=350, Border=0, Mag.Type=8, Smoothing= 4 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=6 n Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu:

Page 500: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 16

n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n D=16, C=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector = don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 501: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 17

Diamond via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Delta 32 vl.3.1 Requirements: 190 rel. 1.7.29 Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024

DICOM Network

Kodak 190 cameraGE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 502: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 18

# Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 190) # Remote Print Host ; 190 - into file C:\D32Tact\system\Mergecom.APP set: [190] (note: use here the same AE Title of the 190 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 190 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 503: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 19

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 cameraGE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 504: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 20

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 2180 - into file C:\D32Tact\system\Mergecom.APP set: [2180] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue)

Page 505: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 21

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 506: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 22

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 cameraGE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 507: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 23

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 1120 - into file C:\D32Tact\system\Mergecom.APP set: [1120] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue)

Page 508: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 24

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 509: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 25

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, KELI 160 v7.2 Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; CS435\CN0\PD1.2 # Smoothing Type ; NORMAL # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 cameraGE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 510: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 26

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 160 - into file C:\D32Tact\system\Mergecom.APP set: [160] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On

Page 511: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 27

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 512: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 28

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, 8700 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700DryView

Fiber Cable

Fiber Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 513: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 29

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 8700 - into file C:\D32Tact\system\Mergecom.APP set: [8700] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Page 514: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 30

n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 515: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 31

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, 8500 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 11INX14IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M8700DryView

Fiber Cable

Fiber Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 516: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 32

Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 8500 - into file C:\D32Tact\system\Mergecom.APP set: [8500] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue

Page 517: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 33

n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=11INx14IN (Always=N), Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 518: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 34

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 519: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 35

# Sample Per Pixel ; 1 # Photometric Interpretation ; MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 8100 - into file C:\D32Tact\system\Mergecom.APP set: [8100] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60

Page 520: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 36

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 521: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 37

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: mammo images printed with this camera are for referral purposes only Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,10 # Smoothing Type ; 6 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 522: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 38

# Photometric Interpretation ;MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 8300 - into file C:\D32Tact\system\Mergecom.APP set: [8300] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 523: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 39

n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109b.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=6 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 524: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 40

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Delta 32 vl.3.1 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ; LUT=0,3 # Smoothing Type ; 4 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 525: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 41

# Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 8610 - into file C:\D32Tact\system\Mergecom.APP set: [8610] (note : use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Mem=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000,Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On

Page 526: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 42

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= gsdfaa0p.w8u (Always=N), Contrast (dry)=3 (Always=N) n Modality Group=6, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing=4, Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=instr n Print Priority=Normal (Always=N), Border=Black (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 527: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 43

Diamond via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Delta 32 vl.3.1 Requirements: MIM 200 v6.1, DV8200 v3.5 Note: mammo images printed with this camera are for referral purposes only Diamond Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 300 # Configuration Information ; LUT=0,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 528: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 44

# Photometric Interpretation ; MONOCHROME2 # Rows ; 1024 # Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the MIM200) # Remote Print Host ; 8200 - into file C:\D32Tact\system\Mergecom.APP set: [8200] (note: use here the same AE Title of the MIM200 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron MIM200 Setup: n on Configure, Network: n Node Name=MIM , IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On

Page 529: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 45

n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM , TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 530: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 46

Diamond via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: Delta 32 vl.3.1 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 8INX10IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ; LUT=gsdfaa0p.w8u,3 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

DICOM Network

Kodak DryView 8900

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 531: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 47

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 8900) # Remote Print Host ; 8900 - into file C:\D32Tact\system\Mergecom.APP set: [8900] (note : use here the same AE Title of the 8900 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 8900 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly n on Configuration, System, Software License: n License Status=Mammo Key is ON n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any

n Media Types: Media=8x10in, 5167x6490, 6234, Any

Page 532: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 48

n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=gsdfaa0p.w8u (Always=N), Contrast=3 (Always=N) n Smoothing Type=11 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 533: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 49

Diamond via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Delta 32 vl.3.1 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Diamond Delta 32 Setup: - into file C:\D32Tact\system\Config.CFG set: (note: change here if other choice for these parameters is wished) Basic Film Session Attributes # Number of copies ; 1 # Print Priority ; HIGH # Medium Type ; BLUE FILM # Film Destination ; PROCESSOR Basic Film Box Attributes # Image Display Format ; 1 # Film Orientation ; PORTRAIT # Film Size ; 14INX17IN # Magnification Type ; CUBIC # Max Density ; 350 # Configuration Information ; LUT=Pmsb.w87,9 # Smoothing Type ; 11 # Border Density ; BLACK # Empty Image Density ; BLACK # Trim ; NO Basic Grayscale Image Box Attributes # Image Position ; 0 # Sample Per Pixel ; 1 # Photometric Interpretation ;MONOCHROME2 # Rows ; 1024

DICOM Network

Kodak DryView 8150

GE-Instrumentarium Diamond mammo systemwith CCD-detector and Delta 32 TACT 3D sw

Page 534: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 50

# Columns ; 1024 # Aspect Ratio (vertical) ; 1 # Aspect Ratio (horizontal) ; 1 # Bits Allocated ; 8 # Bits Stored ; 8 # High Bit ; 7 # Pixel Representation ; 0 # Polarity ; NORMAL - into file C:\D32Tact\system\Config.CFG set: Association Attributes (note : set here the AE Title of the 8150) # Remote Print Host ; DV8150 - into file C:\D32Tact\system\Mergecom.APP set: [DV8150] (note: use here the same AE Title of the 8150 as just above) PORT_NUMBER=5040 HOST_NAME= IP address of 8150 SERVICE_LIST= Print_Service_List - into file C:\D32Tact\system\Mergecom.PRO set: TCPIP_LISTEN_PORT=5040 Note: on GE-Instrumentarium application into Maintenance/Hardcopy at run time choose for images: - Portrait or Landscape - 1 Image (ie 1:1 format) or 6 Images (ie 6:1 format) Note: on GE-Instrumentarium application to print select image, press mouse right button, select Print Note: on GE-Instrumentarium in general only a DICOM camera could be installed Note: GE-Instrumentarium CCD spot=50 micron 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On

Page 535: Other OEM Setup Manuals

GE Instrumentarium Mammography Diamond with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 51

n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=11 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 536: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for GE Mammography Senographe with LASER IMAGERS GE Senographe Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (2,3)........................................................................................................... 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 7

1 setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3, v1.5. 2 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 3 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 537: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

GE Senographe via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: FFDM_RWS_v.10.1, ADS-v:17.2.3, DS-v:30.0, AW-v4.2_04 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Senographe Setup: common to all the 4 GE stations ie RWS, ADS, DS, AW stations: Tools Menu/Printer Management/Add: DICOM printer label=eg Kodak 8610, Host name=host name of 9410 computer eg 9410MFG01, AE Title=9410, Network address=accordingly, Port=1024, Layout 1:1, Slide=not selected, Pixel Depth=not selected, Film Size: 8x10 W=5024,H=6200, Printer pixel size=38.75, Config.Info: LUT=0,3, Dmin=not used, Dmax=350, Magnif.Type=Cubic, Smoothing=1, Trim=No, Printer memory=40 Note: to get the GE Test Pattern loaded, with the pointer on the screen background, eg at the top of the screen till a cross appears, right-click on the mouse and select Service Tools (on AW select Admin)/Install SMPTE only on GE RWS and GE AW stations: into Viewer: into Print Tools Menu/Printer Configuration: select Kodak 8610, set Copies=1, Properties: Edit Media=Blue Film, Dest.=Processor, Film Orientation=Portrait, Film Size=8x10 only on GE ADS and GE DS stations: Tools Menu/Medical Application preferences/AutoPrint: set Auto Print=On (to get film printed after image is acquired and exam is closed) select Kodak 8610, set Print Mode=Fit to Film, set Copies=1 set Printer Properties: Media=Blue Film, Dest.=Processor, Film Orientation=Portrait, Film Size=8x10 Tools Menu/Medical Application preferences/Annotations/select Kodak 8610:

GE Senographe 2000 D

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 538: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

set Model=eg 1 (to get Printing Annotations on film as per correspondent model) only on GE DS station (which uses PLUT): Tools Menu/Review Room Management/Add: Review Room label=eg Room1, Ambient Room Light=eg 10 cd/m^2, Light Box Light=eg 5000 cd/m^2 Tools Menu/Printer Management/Default Room: select Room1, Save and Done 9410 Setup: on SCP PRINTER Menu, Current Provider, SCP Parameters:

n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associatio ns= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= PR_hostname, SCU IPAddr=accordingly, SCP=8610 n Copies=1, Contrast Table=3, Max.Density=350 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=6, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 539: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

GE Senographe via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: FFDM_RWS_v.10.1, ADS-v:17.2.3, DS-v:30.0, AW-v4.2_04 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Senographe Setup: common to all the 4 GE stations ie RWS, ADS, DS, AW stations: Tools Menu/Printer Management/Add: DICOM printer label=eg Kodak 8610, Host name=host name of MIM 200 computer eg MIM, AE Title=8610, Network address=accordingly, Port=5040, Layout 1:1, Slide=not selected, Pixel Depth=not selected, Film Size: 8x10 W=5024,H=6200, Printer pixel size=38.75, Config.Info: LUT=0,3, Dmin=not used, Dmax=350, Magnif.Type=Cubic, Smoothing=1, Trim=No, Printer memory=40 Note: to get the GE Test Pattern loaded, with the pointer on the screen background, eg at the top of the screen till a cross appears, right-click on the mouse and select Service Tools (on AW select Admin)/Install SMPTE only on GE RWS and GE AW stations: into Viewer: into Print Tools Menu/Printer Configuration: select Kodak 8610, set Copies=1, Properties: Edit Media=Blue Film, Dest.=Processor, Film Orientation=Portrait, Film Size=8x10 only on GE ADS and GE DS stations: Tools Menu/Medical Application preferences/AutoPrint: set Auto Print=On (to get film printed after image is acquired and exam is closed) select Kodak 8610, set Print Mode=Fit to Film, set Copies=1 set Printer Properties: Media=Blue Film, Dest.=Processor, Film Orientation=Portrait, Film Size=8x10 Tools Menu/Medical Application preferences/Annotations/select Kodak 8610:

GE Senographe 2000 D

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 540: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

set Model=eg 1 (to get Printing Annotations on film as per correspondent model) only on GE DS station (which uses PLUT): Tools Menu/Review Room Management/Add: Review Room label=eg Room1, Ambient Room Light=eg 10 cd/m^2, Light Box Light=eg 5000 cd/m^2 Tools Menu/Printer Management/Default Room: select Room1, Save and Done MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set:

n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=Y, ToneScaling=PerceptionLUT (Always=Y) n Contrast (dry)=3 (Always=N) n Modality Group=6 (which corresponds to TFT/ULUT=gsdfaa0p.w8u) n Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=Y), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=ge

Page 541: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 542: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

GE Senographe via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: FFDM_RWS_v.10.1, ADS-v:17.2.3, DS-v:30.0, AW-v4.2_04 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Senographe Setup: common to all the 4 GE stations ie RWS, ADS, DS, AW stations: Tools Menu/Printer Management/Add: DICOM printer label=eg Kodak 8900, Host name=host name of 8900 computer eg DV8900, AE Title=8900, Network address=accordingly, Port=5040, Layout 1:1, Slide=not selected, Pixel Depth=not selected, Film Size: 8x10 W=5056,H=6368, 10x12 W=6368,H=7656 Printer pixel size=39.08, Config.Info: LUT=gsdfaa0p.w8u,3, Dmin=not used, Dmax=350, Magnif.Type=Cubic, Smoothing=15, Trim=No, Printer memory=40 Note: to get the GE Test Pattern loaded, with the pointer on the screen background, eg at the top of the screen till a cross appears, right-click on the mouse and select Service Tools (on AW select Admin)/Install SMPTE only on GE RWS and GE AW stations: into Viewer: into Print Tools Menu/Printer Configuration: select Kodak 8900, set Copies=1, Properties: Edit Media=Blue Film, Dest.=Processor, Film Orientation=Portrait, Film Size=8x10 only on GE ADS and GE DS stations: Tools Menu/Medical Application preferences/AutoPrint: set Auto Print=On (to get film printed after image is acquired and exam is closed) select Kodak 8900, set Print Mode=Fit to Film, set Copies=1 set Printer Properties: Media=Blue Film, Dest.=Processor, Film Orientation=Portrait, Film Size=8x10 Tools Menu/Medical Application preferences/Annotations/select Kodak 8900: set Model=eg 1 (to get Printing Annotations on film as per correspondent model)

GE Senographe 2000 D

DICOM Network

Kodak DryView 8900

Page 543: Other OEM Setup Manuals

GE Mammography Senographe with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

only on GE DS station (which uses PLUT): Tools Menu/Review Room Management/Add: Review Room label=eg Room1, Ambient Room Light=eg 10 cd/m^2, Light Box Light=eg 5000 cd/m^2 Tools Menu/Printer Management/Default Room: select Room1, Save and Done 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=Yes, Negotiate Color Print=No n TFT=gsdfaa0p.w8u (Always=N), Contrast=3 (Always=N) n Smoothing Type=15 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 544: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for GE Mammography Senovision with LASER IMAGERS GE Senovision Connection POINT-TO-POINT: n Kodak DryView 8300 LASER IMAGER.......................................................................... 2 n Kodak DryView 8600 LASER IMAGING SYSTEM / for Mammography ........................ 3 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 /

Kodak PACS LINK 9410 ACQUISITION SYSTEM / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography ........................ 4

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 / Kodak PACS LINK MEDICAL IMAGE MANAGER 200 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography ........................ 6

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 / Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 8

Page 545: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

GE Senovision with Kodak DryView 8300 LASER IMAGER

Kodak DryView 8300

RS232 25-to-9 pinHost Adaptor Cable

DASM/LCAM box output

RS232 25-pinControl Cable

RS422 37-pinData Cable

GE SenoVision

25-to-25 NullModem Cable

Requirements: SenoVision rel. 4.0.6, 8300 rel. 4.6 RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable GE Setup: into Service Tool, Install, Filming Install set: Laser Camera=3M_952 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=0 n on 8300 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=16 n Digital Interface: Parity=None, Modality Group=0

Page 546: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

GE Senovision with Kodak DryView 8600 LASER IMAGING SYSTEM / for Mammography

Kodak DryView 8600

RS232 25-to-9 pinHost Adaptor Cable

DASM/LCAM box output

RS232 25-pinControl Cable

RS422 37-pinData Cable

GE SenoVision

25-to-25 NullModem Cable

Requirements: SenoVision rel. 4.0.6, 8600 rel. 2.4 RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable GE Setup: into Service Tool, Install, Filming Install set: Laser Camera=3M_952 8600 Setup: n on 8600 Operator Menu into Test Menu, Display Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.G. 5B, Conv.Kernel=1.0.5 n on 8600 Operator Menu into Configure User set:

n Density=16, Contrast=3, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8600 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=6, Smoothing Group=1

Page 547: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

GE Senovision via ptp with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 and

MIM 200 sending via DICOM Print to Kodak PACS LINK 9410 ACQUISITION SYSTEM and

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

RS23-to-RS42225-to-15 pinConverter Box

GE 25-pinControl Cable

GE 37-pinData Cable

Kodak MIM 200GE Senovision

DASM/LCAM box output

Host Control 232 OUT

Image Data OUT

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

COPCIL board Copper Cable

Control 9 pin

Data 37 pin

Kodak DryView 8610Kodak 9410 PACS Link

DICOM Network

Requirements: GE Senovision v5.0.3 Requirements: MIM200 v3.2.1, 9410 v1.3.1a, 8610 v2.1 Note: into MIM200, Config, Input, Direct Connect, Params Acq, Modify, Set: Timer=10 Note: into MIM200, Config, Destination, Add, Print, Network, Qual, 8600, Set:

SCU: Negotiate Presentation LUT=Off GE Setup: into Service Tool, Install, Filming Install set: Laser Camera=3M_952 MIM200 Setup: n on Configure, Network: n Node Name=e.g., MIM200, IPAddr=addr.of MIM200 n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=GE Senovision Mammo: n Board/Channel=Digital Board 1 Channel 1, Logical Name=sv, n Primary Control Type=M952/P831, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=1024, Lines=1024, Parity=Even, Timer=10, Sync=Off, Pixel=8 n on Configure, Destination, Add, Print, Network, Qualified, 8600, Set:

Page 548: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

n General: Log.Name=8610, IPAddr=addr.of 9410, n General: Database Name=8600, Model=8600, Memory=32 n Media Info: Media=8x10in, 5025x6200, 6200, Blue n DICOM Info: Protocol=DICOM 3.0, Service Class=Basic Grayscale Print n DICOM Info: Port Number=1024, AE Title=IMN_9410, Timers=100 n Supported Item: Collation=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: 1, 2, 4, 6=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=0, Min Vert Sep=6 n Formatting: Trim Width when enabled=0, Trim Width when disabled=0 n Formatting: Pixel Pitch=26.3158 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n SCU: Density Space=On, Luminance Space=On, Perception LUT =On n SCU: Negotiate Presentation LUT=Off n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n at MIM Kpad: (Ready to Store Image appears), press Menu, Destination Setup: n Select Destination=8610, Media Size Select=8x10in n at MIM Kpad: (Ready to Store Image appears), press Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=PerceptionLUT n at MIM Kpad: (Ready to Store Image appears), press Menu, Imaging Options: n Orientation=P, Copies=01, Film Contrast=03, Interpolation=Cubic Spline n Image Dmax=3.50, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT=gsdf6.w8u (don’t care with Negotiate Presentation LUT=Off) n Auto Study=Off, Console=On 9410 Setup: on SCP PRINTER Menu, Current Provider, SCP Parameters:

n Printer=8610, SCP AETitle=IMN_9410, Port=1024, Max.Associations=5 n on SCP PRINTER Menu, Registered User: n SCU AETitle=MIM200, SCU IPAddr=accordingly, SCP=8610 n Copies=1, Contrast Table=3, Max.Density=350 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=6, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=350, Contrast=3, Border Density=0

Page 549: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.1, VRTX32=1.08, Contrast=6.P.1, Conv.Kernel=M.1.0 n on 8610 Operator Menu into Configure User set:

n Density=16, Contrast=3, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=100.00

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=6, Smoothing Group=1

Page 550: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

GE Senovision via ptp with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 and

MIM 200 sending via DICOM Print to Kodak PACS LINK MEDICAL IMAGE MANAGER 200 and

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

Requirements: GE Senovision v5.0.3 Requirements: MIM200 v5.0, 8610 v2.3 Note: into MIM200, Config, Destination, Add, Print, Network, Qual, MIM/8610, Set:

SCU: PLUT Service=Off GE Setup: into Service Tool, Install, Filming Install set: Laser Camera=3M_952 MIM200 Setup: n on Configure, Network: n Node Name=eg MIM, IPAddr= addr.of MIM200 n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config., Input, Direct Connect, Config.Add, Digital, Qual.=GE Senovision Mammo: n Board/Channel=Digital Board 1 Channel 1, Logical Name= sv, n Mod.Name=sv, Primary Control Type= M952/P831, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=1024, Lines=1024, Parity=Even, Timer=10, Sync=Off, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4,1200, RS422, 8, 1, Even, Mem Full=MOV n on Configure, Destination, Add, Print, Network, Qualified, MIM/8610, Set: n General: Log.Name=8610, IPAddr= addr.of MIM200,

RS23-to-RS42225-to-15 pinConverter Box

GE 25-pinControl Cable

GE 37-pinData Cable

Kodak MIM 200GE Senovision

DASM/LCAM box output

Host Control 232 OUT

Image Data OUT

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

COPCIL board Copper Cable

Control 9 pin

Data 37 pin

Kodak DryView 8610Kodak MIM 200

DICOM Network

Page 551: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

n General: Database Name=MIM/8610, Model=8610, Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n DICOM Info: Protocol=DICOM 3.0, Service Class=Basic Grayscale Print n DICOM Info: Port =5040, AE Title=8610, Retry=40, Response=100 n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Interpolation: Cubic Conv.2=On, Cubic Conv.3=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: Req.Size Scale=On, Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=26.3158 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n SCU: Luminance Space=On, Curve Shape=On, Perception LUT =On n SCU: PLUT Service=Off n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n at MIM Kpad: (Ready to Store Image appears), press Menu, Destination Setup: n Select Destination=8610, Media Size Select=8x10in n at MIM Kpad: (Ready to Store Image appears), press Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=PerceptionLUT n at MIM Kpad: (Ready to Store Image appears), press Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=1, Film Contrast=03 n Image Dmax=3.50, Border=Black, Collation=Off, Auto Print=On n TFT/ULUT= gsdfaa0p.w8u, Auto Study=Off, Console=On, Annotation=Off MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610, Set: n General: Log.Name=8610 n General: Database Name=8610, Model=8610, Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On

Page 552: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=26.3158 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= gsdfaa0p.w8u (Always=Y), Contrast (dry)=3 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n ICCProfile=Off (Always=N), Modality=OT (Always=N) n BodyPart=Default (Always=N), Modality Group=6 n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Conv.Group=1, Gamma Table=1, Smoothing Type=1 (Always=Y) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Film Output Dest=Bin 9 (Always=N) 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.3, VRTX32=1.08, Contrast=6.P.1, Conv.Kernel=M.1.0 n on 8610 Operator Menu into Configure User set:

n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 553: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

GE Senovision via ptp with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 and

MIM 200 sending via DICOM Print to Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: GE Senovision v5.0.6 Requirements: MIM200 v6.1 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) GE Setup: into Service Tool, Install, Filming Install set: Laser Camera=3M_952 MIM200 Setup: n on Configure, Network: n Node Name=eg MIM, IPAddr= addr.of MIM200 n Subnet Mask=accordingly, Gateway Addr=accordingly n on Config,Input,Direct Conn,Config.Add,Digital,Qual.=GE Senovision Mammo: n Board/Channel=Digital Board 1 Channel 1, Logical Name= sv, n Mod.Name=sv, Primary Control Type= M952/P831, Com Port=4 n Aux.Control=Conv.Kpad, Com Port=5, Ratio=1,1, Page Prealloc.=Off n on Configure, Input, Direct Connect, Parameters Acquisition, Modify, Set: n Pixels=1024, Lines=1024, Parity=Even, Timer=10, Sync=Off, Pixel=8 n on Configure, Input, Direct Connect, Parameters Autofilming, Modify, Set: n COM4,1200, RS422, 8, 1, Even, Mem Full=MOV n on Configure, Destination, Add, Print, Network, Qualified, 8900, Set:

n General: Log.Name=8900, IPAddr=accordingly n General: Database=8900, Model=8900, Memory=32 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n DICOM Info: Protocol=DICOM 3.0, Service Class=Basic Grayscale Print n DICOM Info: Port=5040,AETitle=NER_8900,Counter=40,Response=100 n Supported Items: Collation=On, Common Text=On, Tonescaling=On n Supported Items: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnif=On, Bilinear=On, Replic=On, Cubic Spline=On

RS23-to-RS42225-to-15 pinConverter Box

GE 25-pinControl Cable

GE 37-pinData Cable

Kodak MIM 200

GE Senovision

DASM/LCAM box output

Host Control 232 OUT

Image Data OUT

RS422 37-to-50 pinDigital Adaptor Cable

Kpad / Host Control Octopus Adaptor Cable

Kodak DryView 8900

DICOM Network

Page 554: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

n Interpolation: Cubic Convolution 2=On, Cubic Convolution 3=On n Format Types: Custom Formats=On, Row Symm.=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.3 n SCU: Luminance Space= On, Variable Border Density=On n SCU: Curve Shape=On, Perception LUT =On, PLUT Service=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at MIM Kpad: press Control (Ready to Store appears), Menu, Service Menu: n into Machine Setup Menu set: Tonescaling=Perception LUT

n at MIM Kpad: press Control (Ready to Store appears), Menu, Destination Setup: n Select Destination= 8900, Media Size Select=8x10in

n at MIM Kpad: press Control (Ready to Store appears), Menu, Imaging Options: n Orientation=P, Copies=01, Smoothing Type=15, Film Contrast=3 n Image Dmax=3.50, Trim=Off, Border=Black, Border Dmax=3.99 n Collation=Off, Auto Print=On, TFT/ULUT= gsdfaa0p.w8u, n Auto Study=Off, Console=On, Page Annotation=Off, Film Output=1

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On

Page 555: Other OEM Setup Manuals

GE Mammography Senovision with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30 n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=gsdfaa0p.w8u (Always=N), Contrast=3 (Always=N) n Smoothing Type=15 (Always=Y), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=Y), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=sv

Page 556: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for GE workstation Centricity RA600 (former RADWorks) with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 4

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8100 LASER IMAGER......................................................................... 6

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 (1) / Kodak DryView 8300 LASER IMAGER......................................................................... 8

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 160 LASER IMAGER .......................................................................... 10

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 12

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (2,3,4) / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (3,4,5) / Kodak DryView 8200 LASER IMAGER......................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (4,5) / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ) .................................... 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (4,5) / Kodak DryView 8100 LASER IMAGER......................................................................... 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (4,5) / Kodak DryView 8300 LASER IMAGER......................................................................... 22

n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 557: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

GE Centricity RA600 via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name=Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=8300, Host Name=IP-Address of 8300 n DICOM: Port=104, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=0,10, Border=Black, Empty Image=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 8INx10IN n Layouts: 1,1; 1,2; 2,2; 2,3 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=2 n on 8300 Service Menu into Configure User set: Modality Group=0

Kodak DryView 8300

DICOM Network

GECentricity RA600workstation

Page 558: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

GE Centricity RA600 via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Centricity RA600 v7.0 Requirements: 190 rel. 1.7.29 Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name=Kodak Wet Laser generic, Trim Lines=Off n General: Description= Kodak 2180, 1120, 190, 160 n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=190, Host Name=IP-Address of 190 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Session Label=AMI Print Service n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support= On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=Normal n DICOM film: Config Info=CS435\CN0, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

DICOM Network

Kodak 190 cameraGECentricity RA600workstation

Page 559: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

GE Centricity RA600 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Centricity RA600 v7.0 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into 9410 Local Printers

Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=9410, Host Name=IP-Address of 9410 n DICOM: Port=1024, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=Pmsv3k.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN (11INx14IN if 8500) n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome 9410 Setup:

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

GECentricity RA600workstation

Page 560: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=No, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 561: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

GE Centricity RA600 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: 9410 v1.6, 8100 v2.4.1 Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=9410, Host Name=IP-Address of 9410 n DICOM: Port=1024, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=Pmsv3k.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

GECentricity RA600workstation

Page 562: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 563: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

GE Centricity RA600 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=9410, Host Name=IP-Address of 9410 n DICOM: Port=1024, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=0,10, Border=Black, Empty Image=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 8INx10IN n Layouts: 1,1; 1,2; 2,2; 2,3 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

GECentricity RA600workstation

Page 564: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 565: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

GE Centricity RA600 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: MIM200 v6.1, 160 v7.2 Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name=Kodak Wet Laser generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=160, Host Name=IP-Address of MIM200 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support= On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=Normal n DICOM film: Config Info=CS435\CN0, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 cameraGECentricity RA600workstation

Page 566: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Interpolation=Cubic, Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 567: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

GE Centricity RA600 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Centricity RA600 v7.0 Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name=Kodak Wet Laser generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=2180, Host Name=IP-Address of MIM200 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support= On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=Normal n DICOM film: Config Info=CS435\CN0, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN, 14INx14IN, 11INx14IN, 8INx10IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 cameraGECentricity RA600workstation

Page 568: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Modality=OT (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 569: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

GE Centricity RA600 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Centricity RA600 v7.0 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name=Kodak Wet Laser generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=1120, Host Name=IP-Address of MIM200 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support= On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=Normal n DICOM film: Config Info=CS435\CN0, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN, 14INx14IN, 11INx14IN, 8INx10IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 cameraGECentricity RA600workstation

Page 570: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 571: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

GE Centricity RA600 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: MIM200 v6.1, 8200 v3.5 Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations->Add->Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=8200, Host Name=IP-Address of MIM200 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=On, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=Pmsv3k.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN, 14INx14IN, 11INx14IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

GECentricity RA600workstation

Page 572: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Blue n Media Info: Media=35x35cm, 4361x4247, 4157, Blue n Media Info: Media=11x14in, 3272x4361, 4271, Blue n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On n Formatting: Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20 n Formatting: Max Img Col=0, Max Img Row=0, n Formatting: Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.1 n SCU: Density Space= On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at Keypad connected to MIM, press Menu, Service Menu, SCP Services: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM / SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 573: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

GE Centricity RA600 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual, 8500 Plus, 8800/8500 Dual and HQ)

Requirements: Centricity RA600 v7.0 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and HQ cameras by basically using the correspondent Model into MIM200 Destination

Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=8700, Host Name=IP-Address of MIM200 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=Pmsv3k.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN (11INx14IN if 8500) n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome MIM200 Setup:

Kodak DryView 8700 Plus

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Kodak MIM 200

GECentricity RA600workstation

Page 574: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 575: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

GE Centricity RA600 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=8100, Host Name=IP-Address of MIM200 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=Pmsv3k.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

Kodak DryView 8100

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Kodak MIM 200

GECentricity RA600workstation

Page 576: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 577: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

GE Centricity RA600 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=8300, Host Name=IP-Address of MIM200 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=0,10, Border=Black, Empty Image=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 8INx10IN n Layouts: 1,1; 1,2; 2,2; 2,3 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add:

Kodak DryView 8300

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

GECentricity RA600workstation

Page 578: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 579: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

GE Centricity RA600 via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name= Kodak DryView generic, Trim Lines=Off n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=8900, Host Name=IP-Address of 8900 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=Pmsv3k.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN, 14INx14IN, 11INx14IN, 10INx12IN, 8INx10IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

DICOM Network

Kodak DryView 8900

GECentricity RA600workstation

Page 580: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=2 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.00 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Density Patch=No n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Sorter Bin=Bin1 (Always=N), Print Date=No, Print Time=No, n Page Nbr=No, Hosp.Name=No, Modality ID=No n Annotation Override=No, Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 581: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

GE Centricity RA600 via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Centricity RA600 v7.0 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name=Kodak DryView generic, Trim Lines=Off n General: Description= Kodak 8900, 8700, 8500, 8200, 8150, 8100 n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=DV8150, Host Name=IP-Address of 8150 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Session Label=AMI Print Service n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info= LUT=Pmsb.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 14INx17IN, 14INx14IN, 11INx14IN n Layouts: 1,1; 1,2; 2,2; 2,3; 3,3; 3,4; 3,5; 4,4; 4,5 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Monochrome 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

DICOM Network

Kodak DryView 8150

GECentricity RA600workstation

Page 582: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 583: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

GE Centricity RA600 via DICOM with Kodak Color Medical Imager 1000

Requirements: Centricity RA600 v7.0 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: Image Data not lutted by GE, lutted by Camera Note: on GE, when Compose Sheet is selected, True size is dimmed Note: on GE, when True Size is selected ie Compose Sheet not selected,

the Caliper (ie scale with tics) is not printed on the film GE Setup: n on Print->Destinations-> Class=DICOM Printer set: n General: Class=DICOM Printer, Name=Kodak DryView generic, Trim Lines=Off n General: Description= Kodak 8900, 8700, 8500, 8200, 8150, 8100 n General: Save All Image Data=Off, Merge Series=Off n DICOM: AE Title=CMI1000, Host Name=IP-Address of CMI1000 n DICOM: Port=5040, Destination=Processor, Enable Print Job Events=Off n DICOM: Session Label=AMI Print Service n DICOM: Compose Sheet=Off, BFS Print Support=Off, Use True Size=Off n DICOM: Timeout=180, Trim Support=On, Use Presentation LUT=Off n DICOM film: Magnif.=Cubic, Medium=Blue Film, Smoothing=2 n DICOM film: Config Info=LUT=Pmsv3k.w87,9, Border=Black, Empty=Black n DICOM film: Minimum Density=20, Maximum Density=300 n DICOM film: Annotation Box: Display Format=1, Position=1 n DICOM film: Annotation Box: Format=%d %t %u n DICOM film: Advanced=Off (Max X Size, Max Y Size) n DICOM media: 8INx10IN n Layouts: 1,1; 1,2; 2,2; 2,3 n Image: Min.Bitmap Size=256, Bit Depth=8, Orig.Size=Off, Color=Color CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

DICOM Network

GECentricity RA600workstation

Kodak CMI 1000

Page 584: Other OEM Setup Manuals

GE workstation Centricity RA600 (former RADWorks) with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 585: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for IMS Mammography Biopsy Digit Mam with LASER IMAGERS IMS Biopsy Digit Mam Connection POINT-TO-POINT: n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) ....................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) ....................... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8100 LASER IMAGER.......................................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8300 LASER IMAGER.......................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) .................................................................................................................. 10

n Kodak PACS LINK 9410 ACQUISITION SYSTEM / Kodak Digital Science 969 HQ LASER IMAGER ....................................................... 12

Page 586: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

IMS Biopsy Digit Mam with Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

DPCCopper Cable

DPI4-to-DPC Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

IMS 25-pinControl Cable

IMS 37-pinData Cable

Fiber Cable

Fiber Cable

25-9 DPC-UKEIB Cable

Kodak 9410 PACS Link

Imager

IMS Biopsy Digit Mam 25-to-25 NullModem Cable

Host Control 232 OUT

Image Data OUT

3M8700DryView

Kodak DryView 8700 Plus

Requirements: IMS DigiMam platform rel. 4.2.30.10, 9410 v1.3.3, 8700 v1.24 Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into 9410 Local Printers IMS Setup: n on IMS run LCAMconf.exe n into LaserCam Specs at conf, with right mouse button select Add new LCAM Specs n set Enter Prototype=3m8700ptr, LCAM Device=DASM-LCAM-3M, BITS_OUT=8 n Save all and copy file Spooler/conf/3m8700ptr/config.dat into Spooler/conf directory n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Center RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8700, Model=8700, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=8, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0

Page 587: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on I/O CARD SETUP, DPI4 Digital Menu:

n Image Data Port: Header, 8 bit, Timeout=60, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=ims, Hosp=ims, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8700, Film Destination=Processor, Printer1=8700(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Pmsv3k.w87, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=9, D=14 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=8, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 588: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

IMS Biopsy Digit Mam with Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

DPCCopper Cable

DPI4-to-DPC Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

IMS 25-pinControl Cable

IMS 37-pinData Cable

Fiber Cable

Fiber Cable

25-9 DPC-UKEIB Cable

Kodak 9410 PACS Link

Imager

IMS Biopsy Digit Mam 25-to-25 NullModem Cable

Host Control 232 OUT

Image Data OUT

3M8700Dr yVie w

Kodak DryView 8500 Plus

Requirements: IMS DigiMam platform rel. 4.2.30.10, 9410 v1.3.3, 8500 v1.24 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers IMS Setup: n on IMS run LCAMconf.exe n into LaserCam Specs at conf, with right mouse button select Add new LCAM Specs n set Enter Prototype=3m8500ptr, LCAM Device=DASM-LCAM-3M, BITS_OUT=8 n Save all and copy file Spooler/conf/3m8500ptr/config.dat into Spooler/conf directory n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Center RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8500, Model=8500, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=8, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0

Page 589: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on I/O CARD SETUP, DPI4 Digital Menu:

n Image Data Port: Header, 8 bit, Timeout=60, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=ims, Hosp=ims, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8500, Film Destination=Processor, Printer1=8500(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Pmsv3k.w87, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=11x14, C=9, D=14 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=8, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 590: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

IMS Biopsy Digit Mam with Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8100 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostHost Control 232 OUT

Image Data OUT

IMS 25-pinControl Cable

IMS 37-pinData Cable

IMS Biopsy Digit Mam

Kodak DryView 8100

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

Kodak 9410 PACS Link

COPCIL BoardCopper Cable

RS4229-pole Plug

Imager

25-to-25 NullModem Cable

Requirements: IMS DigiMam platform rel. 4.2.30.10, 9410 v1.3.3, 8100 v1.1.2 IMS Setup: n on IMS run LCAMconf.exe n into LaserCam Specs at conf, with right mouse button select Add new LCAM Specs n set Enter Prototype=3m8700ptr, LCAM Device=DASM-LCAM-3M, BITS_OUT=8 n Save all and copy file Spooler/conf/3m8700ptr/config.dat into Spooler/conf directory n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Center RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=60, Parity=None, Memory=7

Page 591: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200 on Device Setup, HOST KEYPADS:

n Kpad=ims, Hosp=ims, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8100, Film Destination=Processor, Printer1=8100(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Pmsb.w87, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=9, D=14 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=60, P1,…,P6=0 n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 592: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

IMS Biopsy Digit Mam with Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8300 LASER IMAGER

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostHost Control 232 OUT

Image Data OUT

IMS 25-pinControl Cable

IMS 37-pinData Cable

IMS Biopsy Digit Mam

Kodak DryView 8300

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

Kodak 9410 PACS Link

COPCIL BoardCopper Cable

Imager

25-to-25 NullModem Cable

Requirements: IMS DigiMam platform rel. 4.2.30.10 Requirements: 9410 v1.3.3, 8300 v4.6, 8300 LUT v2.0.0 Note: since matrix of IMS is 1024, only formats 1:1, 2:1, 4:1 are printed on 8300 IMS Setup: n on IMS run LCAMconf.exe n into LaserCam Specs at conf, with right mouse button select Add new LCAM Specs n set Enter Prototype=3m8300ptr, LCAM Device=DASM-LCAM-3M, BITS_OUT=8 n Save all and copy file Spooler/conf/3m8700ptr/config.dat into Spooler/conf directory n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Center RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8300 Copper, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0

Page 593: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u on I/O CARD SETUP, DPI4 Digital Menu:

n Image Data Port: Header, 8 bit, Timeout=60, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=ims, Hosp=ims, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8300, Film Destination=Processor, Printer1=8300(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=u1_109b.w8u, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=8x10, C=10, D=16 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 594: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

IMS Biopsy Digit Mam with Kodak PACS LINK 9410 ACQUISITION SYSTEM /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

DPCCopper Cable

DPI4 Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

HostHost Control 232 OUT

Image Data OUT

IMS 25-pinControl Cable

IMS 37-pinData Cable

IMS Biopsy Digit Mam

Kodak DryView 8610

Control 9-pin

Data 37 pin

DPC-to-UKEIB Cable

Kodak 9410 PACS LinkModality ServerCOPCIL Board

Copper Cable

Imager

25-to-25 NullModem Cable

Kodak 9410 PACS LinkDICOM Print Server

DICOM Network Requirements: IMS DigiMam platform v4.2.30.10 Requirements: 9410 v1.3.3, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: for the 8600 this configuration could be also reduced

to 1 single 9410 which concentrates both functionalities: - the point-to-point image acquisition (i.e., Modality Server functionality) - the local printing on 8610 (or 8600) (i.e., DICOM Print Server functionality).

IMS Setup: n on IMS run LCAMconf.exe n into LaserCam Specs at conf, with right mouse button select Add new LCAM Specs n set Enter Prototype=3m8300ptr, LCAM Device=DASM-LCAM-3M, BITS_OUT=8 n Save all and copy file Spooler/conf/3m8300ptr/config.dat into Spooler/conf directory n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Center RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable 9410 Modality Server Setup:

on Device Setup, SCU PRINTERS: n Printer=8610, Model=8600/8610, Port=1024, IPAddr=accordingly

Page 595: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

n SCU AE Title=KDK_9410, SCP AE Title=9410 n LUT String Supported=Off, Annotation Supported=Off, Print Guaranteed=On n into Adv.Options: Replic.=NONE, Bilinear=NONE, Cubic=1, None=NONE n into Adv.Options: Blue=BLUE, Clear=CLEAR, None=CURRENT n Film Size=8x10, Film Type=Blue, Film Destination=Current, Contrast=3 n MinD=0, MaxD=350, Interp.Type=831 DICOM, Interp.Num=1, TFT=don’t care

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=60, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

on Device Setup, HOST KEYPADS: n Kpad=ims, Hosp=ims, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=8610, Film Destination=Processor, Printer1=8610(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=don’t care, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=8x10, C=3, D=16 9410 DICOM Print Server Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations=5 n on SCP PRINTER Menu, Registered User: n SCU AETitle=TEST_PRINT_SCU, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=3 n Max.Density=350, Border=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=6, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=350, Contrast=3, Border=0

8610 Setup: n on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=3, Sharp/Smooth=1, Layout: 1 on 1=P n Gamma=Xmittance, Image Size=Scale To Fit, Detector =don’t care n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=6, Smoothing Group=1

Page 596: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

IMS Biopsy Digit Mam with Kodak PACS LINK 9410 ACQUISITION SYSTEM / Kodak Digital Science 969 HQ LASER IMAGER

DPCCopper Cable

DPI4-to-DPC Cable

UKEIB

RS232 25-to-9 pinHost Adaptor Cable

Host

IMS 25-pinControl Cable

IMS 37-pinData Cable

Fiber Cable

Fiber Cable

25-9 DPC-UKEIB Cable

Kodak 9410 PACS Link

Imager

IMS Biopsy Digit Mam 25-to-25 NullModem Cable

Host Control 232 OUT

Image Data OUT

Kodak M969 HQ

3 M H Q L a s e r I m a g e r

Requirements: IMS DigiMam platform rel. 4.2.30.10, 9410 v1.3.3, M969 v5.1 IMS Setup: n on IMS run LCAMconf.exe n into LaserCam Specs at conf, with right mouse button select Add new LCAM Specs n set Enter Prototype=3m969hq, LCAM Device=DASM-LCAM-3M, BITS_OUT=8 n Save all and copy file Spooler/conf/3m969hq/config.dat into Spooler/conf directory n on UKEIB set OFF/ON/OFF/OFF/ON/OFF, Switch=Center RS232 25-to-9 Host 25 pin side 2 3 7 Adaptor Cable pinout 9 pin side 4 6 1 Note: if 25-to-25 Null Modem Cable is not available,

cross pin 2 and 3 on 25-side of 25-to-9 RS232 Host Adaptor Cable 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=969, Model=969, Output=Fiber n Baud=19200, Parity=None, Data=8, Stop=1, Command Set=SuperSet n Pixel=8, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on I/O CARD SETUP, DPI4 Digital Menu: n Image Data Port: Header, 8 bit, Timeout=60, Parity=None, Memory=7 n Serial Port: Protocol=952, Parity=Even, Baud Rate=1200

Page 597: Other OEM Setup Manuals

IMS Mammography Biopsy Digit Mam with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 13

on Device Setup, HOST KEYPADS: n Kpad=ims, Hosp=ims, Serial=DPI4 A Host, Image=DPI4 A DATA n Available Printer=969, Film Destination=Processor, Printer1=969(Processor) n 300 DPI=Off, Scale Magnif.=Off, Scale Format / Pixel Correction=On n TFT/ULUT=Pmsv3k.w87, Mem.Full =On, Image Size =On, Alarm Mode=On n into Defaults: Destination=Printer 1, Media Size=14x17, C=9, D=14 M969 HQ Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=8, Header/Line, Parity=Enable Even, Port=0, Timeout=60

Page 598: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for IMS Mammography Giotto Image MD / SD with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER.......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER........................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) ....................... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) ....................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER.......................................................................... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER.......................................................................... 10 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) .................................................................................................................. 12

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak Digital Science 969 HQ LASER IMAGER ....................................................... 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER........................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER........................................................................ 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER........................................................................ 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (1) / Kodak DryView 8200 LASER IMAGER.......................................................................... 22

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (1) / Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)............................... 24

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (1) / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) ....................... 26

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (1) / Kodak DryView 8100 LASER IMAGER.......................................................................... 28

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (1) / Kodak DryView 8300 LASER IMAGER.......................................................................... 30

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (1) / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) ........................................................................................................................................................ 32

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 (1) / Kodak Digital Science 969 HQ LASER IMAGER.......................................................................... 34

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 36 n Kodak DryView 8150 LASER IMAGER.......................................................................... 38 1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 599: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

IMS Giotto Image MD / SD via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 8300 v4.9.1, 8300 LUT v3.0.3B, 8300 DICOM board v3.3 Note: mammo images printed with this camera are for referral purposes only Note: it work only with IMS Raffaello v1.1.0.5 because of 8 bit support IMS Raffaello Setup: under Tools/DICOM Configuration/Remote Printers click on Load From File and select Filename=Kodak DryView 8300 check that: Description=8300, AE_TITLE=8300, Hostname=IPaddr.of 8300 Port=104, Rows=2676, Columns=2256, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=2, Magnification Type=CUBIC, Configuration Information= LUT=0,10 Photometric Interpretation=MONOCHROME2, Requested Image Size=Off, Auto Orientation=On, Presentation LUT=Off, Auto print=Off, Default (Printer)=On, Padding=On, Trim=Off, Labels=On, 8bit=On click Add and Close To print select an image and press DICOM Print and with Printer=8610 press Print 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=2 n on 8300 Service Menu into Configure User set:

n Modality Group=0

Kodak DryView 8300

DICOM Network

IMSGiotto Image MDmammography system

Page 600: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

IMS Giotto Image MD / SD via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 190 rel. 1.7.29 Note: mammo images printed with this camera are for referral purposes only IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=190, AE_TITLE=190, Hostname=IPaddr.of MIM200 Port=5040, Rows=5120, Columns=4096, Film Destination=PROCESSOR, Film size=14INx17IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=1, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [190] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=CS435\CN0 (to send Curve Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=190 press Print 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

DICOM Network

Kodak 190 cameraIMSGiotto Image MDmammography system

Page 601: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 9410 v1.6, 8500 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8500, AE_TITLE=9410, Hostname=IPaddr.of 9410 Port=1024, Rows=4280, Columns=3380, Film Destination=PROCESSOR, Film size=11INx14IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [9410] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send the Contrast setting). To print select an image and press DICOM Print and with Printer=8500 press Print 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M8700DryView

Fiber Cable

Fiber Cable

IMSGiotto Image MDmammography system

Page 602: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=15 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 603: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 9410 v1.6, 8700 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into 9410 Local Printers IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8700, AE_TITLE=9410, Hostname=IPaddr.of 9410 Port=1024, Rows=5220, Columns=4096, Film Destination=PROCESSOR, Film size=14INx17IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [9410] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send the Contrast setting). To print select an image and press DICOM Print and with Printer=8700 press Print 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M8700DryView

Fiber Cable

Fiber Cable

IMSGiotto Image MDmammography system

Page 604: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=15 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 605: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 8

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 9410 v1.6, 8100 v2.4.1 Note: mammo images printed with this camera are for referral purposes only IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8100, AE_TITLE=9410, Hostname=IPaddr.of 9410 Port=1024, Rows=5216, Columns=4096, Film Destination=PROCESSOR, Film size=14INx17IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [9410] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send the Contrast setting). To print select an image and press DICOM Print and with Printer=8100 press Print 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

IMSGiotto Image MDmammography system

Page 606: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 9

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=15 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 607: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 10

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: mammo images printed with this camera are for referral purposes only IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8300, AE_TITLE=9410, Hostname=IPaddr.of 9410 Port=1024, Rows=2676, Columns=2256, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=2, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [9410] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=u1_109b.w8u,10 (to send Shape+Contrast setting). To print select an image and press DICOM Print and with Printer=8300 press Print 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

KodakDryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

IMSGiotto Image MDmammography system

Page 608: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 11

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No, Print Always=Yes n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 609: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 12

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: IMS Raffaello MD/SD v1.1.0.5 or IMS iWorks rel. SQA5 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera IMS Raffaello Setup: under Tools/DICOM Configuration/Remote Printers click on Load From File and select Filename=Kodak DryView 8610 check that: Description=8610, AE_TITLE=9410, Hostname=IPaddr.of 9410 Port=5040, Rows=6200, Columns=5024, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=350 Smoothing Type=1, Magnification Type=CUBIC, Configuration Information= LUT=0,3 Photometric Interpretation=MONOCHROME2, Requested Image Size=Off, Auto Orientation=On, Presentation LUT=Off, Auto print=Off, Default (Printer)=On, Padding=On, Trim=Off, Labels=On, 8bit=Off click Add and Close if not available into C:\WINNT\DICOMServices.ini under the section [9410] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=0,3 (to send the Contrast setting). To print select an image and press DICOM Print and with Printer=8610 press Print IMS iWorks Setup: Set under iWorks/Utilities/Server Tools/Modify DICOM destination table: AE TITLE=9410, HOST=IPaddr.of 9410, PORT=1024, ALIAS=Kodak 8610 Set under D:\iWorks\Config\ftp_config to be opened with Workpad ROUTE1_TYPE=DICOM_PRINT_BURNED_PROCESSING ROUTE1_ADDR=9410

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

IMSGiotto Image MDmammography system

Page 610: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 13

ROUTE1_DESTINATION=d:\iWorks\dicom_store 9410 Setup: on SCP PRINTER Menu, Current Provider, SCP Parameters:

n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr=accordingly, SCP=8610 n Copies=1, Contrast Table=3, Max.Density=350 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=6, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz

n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 611: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 14

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 9410 v1.6, 969 v5.2 Note: mammo images printed with this camera are for referral purposes only Note: other HQ matrixes 14x17=4096x4992, 11x14=3020x3960 IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=969, AE_TITLE=9410, Hostname=IPaddr.of 9410 Port=1024, Rows=2788, Columns=2076, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [9410] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=969 press Print 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=969, Model=969, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=969, AE Title= 9410, Port= 1024, Max Associations= 5

Kodak 9410 PACS Link

DICOM Network

Fiber Cable

Fiber Cable

IMSGiotto Image MDmammography system

3 M H Q L a s e r I m a g e r

Kodak M969 HQ

Page 612: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 15

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=969, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=15 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 613: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 16

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, KELI 160 v7.2 Note: mammo images printed with this camera are for referral purposes only IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=160, AE_TITLE=160, Hostname=IPaddr.of MIM200 Port=5040, Rows=5348, Columns=4360, Film Destination=PROCESSOR, Film size=14INx17IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=1, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [160] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=CS435\CN0 (to send Curve Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=160 press Print MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 cameraIMSGiotto Image MDmammography system

Page 614: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 17

n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=Black (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 615: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 18

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: mammo images printed with this camera are for referral purposes only Note: other 2180 matrixes 14x17=4096x5156, 14x14=4096x4132, 11x14=3236x4132 IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=2180, AE_TITLE=2180, Hostname=IPaddr.of MIM200 Port=5040, Rows=2836, Columns=2286, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=1, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [2180] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=CS435\CN0 (to send Curve Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=2180 press Print MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue)

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 cameraIMSGiotto Image MDmammography system

Page 616: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 19

n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=Black (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Film Output Dest=Bin 9 (Always=N), Negotia te Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 617: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 20

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: mammo images printed with this camera are for referral purposes only Note: other 1120 matrixes 14x17=4096x5132, 14x14=4096x4108, 11x14=4096x3232 IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=1120, AE_TITLE=1120, Hostname=IPaddr.of MIM200 Port=5040, Rows=2900, Columns=2304, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=1, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [1120] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=CS435\CN0 (to send Curve Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=1120 press Print MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue)

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 cameraIMSGiotto Image MDmammography system

Page 618: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 21

n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=Black (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 619: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 22

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM 200 v6.1, DV8200 v3.5 Note: mammo images printed with this camera are for referral purposes only Note: other 8200 matrixes 14x17=4360x5220, 14x14=4360x4244 IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8200, AE_TITLE=8200, Hostname=IPaddr.of MIM200 Port=5040, Rows=4360, Columns=3272, Film Destination=PROCESSOR, Film size=11INx14IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [8200] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=8200 press Print MIM200 Setup: n on Configure, Network: n Node Name=MIM , IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear)

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

IMSGiotto Image MDmammography system

Page 620: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 23

n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=15 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM , TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 621: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 24

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, 8500 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8500, AE_TITLE=8500, Hostname=IPaddr.of MIM200 Port=5040, Rows=4280, Columns=3380, Film Destination=PROCESSOR, Film size=11INx14IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [8500] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=8500 press Print MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M8700DryView

Fiber Cable

Fiber Cable

IMSGiotto Image MDmammography system

Page 622: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 25

n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=15 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=11INx14IN (Always=N), Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 623: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 26

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, 8700 v1.34 Note: mammo images printed with this camera are for referral purposes only Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into MIM200 Destination IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8700, AE_TITLE=8700, Hostname=IPaddr.of MIM200 Port=5040, Rows=5220, Columns=4096, Film Destination=PROCESSOR, Film size=14INx17IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [8700] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=8700 press Print MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700DryView

Fiber Cable

Fiber Cable

IMSGiotto Image MDmammography system

Page 624: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 27

n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=15 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 625: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 28

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: mammo images printed with this camera are for referral purposes only IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8100, AE_TITLE=8100, Hostname=IPaddr.of MIM200 Port=5040, Rows=5216, Columns=4096, Film Destination=PROCESSOR, Film size=14INx17IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [8100] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=8100 press Print MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

KodakDryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

IMSGiotto Image MDmammography system

Page 626: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 29

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=15 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 627: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 30

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: mammo images printed with this camera are for referral purposes only IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8300, AE_TITLE=8300, Hostname=IPaddr.of MIM200 Port=5040, Rows=2676, Columns=2256, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=2, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [8300] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=u1_109b.w8u,10 (to send Shape+Contrast setting). To print select an image and press DICOM Print and with Printer=8300 press Print MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

IMSGiotto Image MDmammography system

Page 628: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 31

n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109b.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 629: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 32

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: IMS Raffaello MD/SD v1.1.0.5 or IMS iWorks rel. SQA5 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera IMS Raffaello Setup: under Tools/DICOM Configuration/Remote Printers click on Load From File and select Filename=Kodak DryView 8610 check that: Description=8610, AE_TITLE=8610, Hostname=IPaddr.of MIM200 Port=5040, Rows=6200, Columns=5024, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=350 Smoothing Type=1, Magnification Type=CUBIC, Configuration Information= LUT=0,3 Photometric Interpretation=MONOCHROME2, Requested Image Size=Off, Auto Orientation=On, Presentation LUT=Off, Auto print=Off, Default (Printer)=On, Padding=On, Trim=Off, Labels=On, 8bit=Off click Add and Close if not available into C:\WINNT\DICOMServices.ini under the section [8610] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=0,3 (to send the Contrast setting). To print select an image and press DICOM Print and with Printer=8610 press Print IMS iWorks Setup: Set under iWorks/Utilities/Server Tools/Modify DICOM destination table: AE TITLE=8610, HOST=IPaddr.of MIM200, PORT=5040, ALIAS=Kodak 8610 Set under D:\iWorks\Config\ftp_config to be opened with Workpad ROUTE1_TYPE=DICOM_PRINT_BURNED_PROCESSING ROUTE1_ADDR=8610

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

IMSGiotto Image MDmammography system

Page 630: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 33

ROUTE1_DESTINATION=d:\iWorks\dicom_store MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n Contrast (dry)=3 (Always=N) n Modality Group=6 (which corresponds to TFT/ULUT=gsdfaa0p.w8u) n Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=ims n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

Page 631: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 34

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 632: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 35

IMS Giotto Image MD / SD via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: MIM200 v6.1, 969 v5.2 Note: mammo images printed with this camera are for referral purposes only Note: other HQ matrixes 14x17=4096x4992, 11x14=3020x3960 IMS Raffaello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=969, AE_TITLE=969, Hostname=IPaddr.of MIM200 Port=5040, Rows=2788, Columns=2076, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [969] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsv3k.w87,9 (to send Shape and Contrast setting). To print select an image and press DICOM Print and with Printer=969 press Print MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 969, Set: n General: Log.Name=969 n General: Database Name=969, Model=969, Memory=32 n Media Info: Media=35x43cm, 4096x5002, 4912, Blue

Kodak MIM 200

DICOM Network

Fiber Cable

Fiber Cable

IMSGiotto Image MDmammography system

3 M H Q L a s e r I m a g e r

Kodak M969 HQ

Page 633: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 36

n Media Info: Media= 11x14in, 3030x4096, 4006, Blue n Media Info: Media= 8x10in, 2086x2929, 2839, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.3457 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsv3k.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=15 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off 969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 634: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 37

IMS Giotto Image MD / SD via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: IMS Raffaello MD/SD v1.1.0.5 or IMS iWorks rel. SQA5 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) IMS Raffello Setup: under Tools/DICOM Configuration/Remote Printers click on Load From File and select Filename=Kodak DryView 8900 check that: Description=8900, AE_TITLE=8900, Hostname=IPaddr.of 8900 Port=5040, Rows=6368, Columns=5056, Film Destination=PROCESSOR, Film size=8INx10IN, Medium Type=BLUE FILM, Min density=0, Max density=350 Smoothing Type=15, Magnification Type=CUBIC, Configuration Information= LUT=gsdfaa0p.w8u,3 Photometric Interpretation=MONOCHROME2, Requested Image Size=Off, Auto Orientation=On, Presentation LUT=Off, Auto print=Off, Default (Printer)=On, Padding=On, Trim=Off, Labels=On, 8bit=Off click Add and Close if not available into C:\WINNT\DICOMServices.ini under the section [8900] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=gsdfaa0p.w8u,3 (to send Shape andContrast setting). To print select an image and press DICOM Print and with Printer=8900 press Print IMS iWorks Setup: Set under iWorks/Utilities/Server Tools/Modify DICOM destination table: AE TITLE=8900, HOST=IPaddr.of 8900, PORT=5040, ALIAS=Kodak 8900 Set under D:\iWorks\Config\ftp_config to be opened with Workpad ROUTE1_TYPE=DICOM_PRINT_BURNED_PROCESSING ROUTE1_ADDR=8900 ROUTE1_DESTINATION=d:\iWorks\dicom_store 8900 Setup:

IMSGiotto Image MDmammography system

DICOM Network

Kodak DryView 8900

Page 635: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 38

n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=gsdfaa0p.w8u (Always=N), Contrast=3 (Always=N) n Smoothing Type=15 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ims

Page 636: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 39

IMS Giotto Image MD / SD via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: IMS Raffaello MD/SD v1.1.0.5 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) IMS Raffello Setup: Set under Tools/DICOM Configuration/Remote Printers set: Description=8150, AE_TITLE=DV8150, Hostname=IPaddr.of 8150 Port=5040, Rows=5390, Columns=4438, Film Destination=PROCESSOR, Film size=14INx17IN, Medium Type=BLUE FILM, Min density=0, Max density=300 Smoothing Type=15, Magnification Type=CUBIC, Photometric Interpretation=MONOCHROME2, Labels=On, Auto print=Off, Default (Printer)=On click Add and Close if needed into C:\WINNT\DICOMServices.ini under the section [8150] add: trim=1 (to turn on the trim), requested_image_size=1 (to turn on Req.ImageSize), configuration_information=LUT=Pmsb.w87,9 (to send Shape andContrast setting). To print select an image and press DICOM Print and with Printer=8150 press Print 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On

IMSGiotto Image MDmammography system

DICOM Network

Kodak DryView 8150

Page 637: Other OEM Setup Manuals

IMS Mammography Giotto Image MD / SD with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 40

n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=15 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 638: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 1

Specific Setup for Merge workstation eFilm with LASER IMAGERS OEM Data Manufacturer Merge Modality workstation Model eFilm sw version v1.8.3 Implement. Class UID 1.2.804.114118.3 Implement. Version Name eFilm Kodak Data DICOM-interface MIM internal / external or 9410 as below reported DICOM-intf sw version as below reported Printer model All cameras as below reported Printer sw version as below reported What’s new: The setup of a Kodak printer for a given OEM Modality was split in 2 separate documents: - the generic Setup Catalog for Kodak Cameras - the specific Setup Manual for a given OEM Modality

************* the generic Setup Catalog for Kodak Cameras: the Setup Catalog for Kodak Cameras contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Setup Catalog for Kodak Cameras

(ie go to the Setup Catalog doc and do that first, then come back here and finish install as per this Specific Setup Manual doc). ************ the specific Setup Manual for a given OEM Modality: the Setup Manual for a given OEM Modality contains that part of a printer installation which is Specific to that particular OEM Modality to be connected, ie the OEM console Settings and the printer Image Quality parameters. Therefore, as second and final step, setup the printer as per the indications reported here into the Setup Manual for that particular OEM Modality. Note that the Setup Manual has 2 sections ie the DryView section and the Wet section.

Page 639: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 2

What’s inside this document: n OEM Modality Setup (ie how to configure,into the OEM console,the Kodak printer) 2 n DryView correspondance with Kodak Setup Catalog for DryView cameras................ 3 n Image Quality setup into MIM (or 9410) for DryView cameras ............................... 4 n More info on OEM Modality when connected to DryView cameras .............................. 5 n Wet correspondance with Kodak Setup Catalog for Wet cameras .................................. 6 n Image Quality setup into MIM (or 190) for Wet cameras ............................................... 7 n More info on OEM Modality eg Page-Mode and IQ parameters sent out by OEM ........ 8 n Miscellaneous: Deviations from Kodak Setup Catalog / Known Problems / Notes........ 9 OEM Modality Setup ie how to configure into the OEM console the Kodak printer: Note: MIM setup is basically also valid for 9410 by using AE=9410, Port=1024 eFilm Setup: n into File/DICOM Print/DICOM Printers set: n Description=DryView, AE Title=DV8150, Hostname=IP-address accordingly n Port=5040, Format=STANDARD\4,5, Priority=MED, Medium=BLUE FILM n Copies=1, Film Orientation=PORTRAIT, Film Size=14INX17IN n Film Destination=PROCESSOR, Resolution=300 DPI n Magnification Type=CUBIC, Smoothing= no entry, Trim=NO n Dmin=20, Dmax=300, Border=BLACK, Empty=399, Polarity=NORMAL n Click Add, OK

Page 640: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 3

DryView section: Setup for Kodak DryView cameras ie 8900, 8700, 8610, 8600, 8500, 8300, 8200, 8150, 8100, 1000 Correspondance with Kodak Setup Catalog for DryView cameras: Note: the Kodak Setup Catalog contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Kodak Setup Catalog, and then, as second and final step, setup the Image Quality parameters as per the Setup Manual for the Specific OEM Modality here below reported. MIM (inside printer) 8900 8150 into Kodak catalog see Setup as per page

19 20

MIM sw version 5.6.b5 5.7.b8 Printer sw version Rev.E ie 2.11 1.0.2.b04 MIM external 8700, 8500 8100 8300 8610 (8600) 8200 1000 into Kodak catalog see Setup as per page

15 16 17 18 14 21

MIM sw version 6.1 6.1 6.1 6.1 6.1 2.0.b3 Printer sw version 1.34 2.4.1 3.5 2.4 (2.5) 4.9.1 1.0.b8 9410 external 8700, 8500 8100 8300 8610 (8600) into Kodak catalog see Setup as per page

7 8 9 10

9410 sw version 1.6 1.6 1.6 1.6 Printer sw version 1.34 2.4.1 3.5 2.4 (2.5)

Page 641: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 4

Image Quality setup into MIM (or 9410) for DryView cameras: MIM (or 9410) Parameters

8900, 8150, 8700, 8500, 8200, 8100,

1000 (see Note1 below)

8300 (see Note2 below,

confirm Y/N)

8610, 8600

TFT/ULUT (8610 Modality/Contrast Group) (Always Apply=Y/N)

Pmsv3k.w87

(Y)

u1_109s.w8u

(Y)

(gsdfaa0p.w8u) 6

Contrast (Always Apply=Y/N)

9 (Y)

10 (Y)

3 (Y)

Max.Density (Always Apply=Y/N)

300 (Y)

300 (Y)

350 (Y)

Smoothing (Always Apply=Y/N)

2 (Y)

2 (Y)

1 (Y)

Presentation ie PLUT=Y/N (not available on 9410)

N N N

8610 Convolution / Kernel Group Not available Not available 1 8610 Gamma Table Not available Not available Transmittance Note1: in particular for 8100, 8200, 8150 use TFT=Pmsb.w87. Note2: OEM Modality tested also with 8300 standalone ie without MIM or 9410 in front? (Yes/No, parameters)

Yes Mod.Gr.=0, D=16, C=10, smooth=1

Page 642: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 5

More info on OEM Modality when connected to DryView cameras:

Works the OEM Modality in Page-Mode? (Yes/No) No Note: see Page-Mode definition and matrixes into Kodak cameras setup catalog. Are Image Data lutted by the OEM Modality, ie Linear-in-Density LUT into Camera? (Yes/No)

No

Note: Linea-in-Density LUT into Camera means eg TFT=Wrkstn2a.w87, Dmax=3.00, C=2. Which are the Image Quality parameters sent out by the OEM Modality: DICOM Parameters

Sent out by Modality (Yes/No)

Value sent out for 8900, 8150, 8700, 8500, 8200, 8100,

1000

Value sent out for 8300

Value sent out for 8610, 8600

Config. Information (LUT=TFT,Contrast)

No

Max. Density Yes 300 300 300 Magnification Yes CUBIC CUBIC CUBIC Smoothing No PLUT No Illumination (PLUT) No Reflective Ambient Light (PLUT)

No

Page 643: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 6

Wet section: Setup for Kodak Wet cameras ie 160, 2180, 1120, 190 Correspondance with Kodak Setup Catalog for Wet cameras: Note: the Kodak Setup Catalog contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Kodak Setup Catalog, and then, as second and final step, setup the Image Quality parameters as per the Setup Manual for the Specific OEM Modality here below reported. 160 2180 1120 190 into Kodak catalog see Setup as per page

11 12 13 6

MIM sw version 6.1 6.1 6.1 Not present Printer sw version 7.2 2.17H 2.40 / 032 1.7.29 Note: in regards to 969 parameters use the same as per 8700 setup.

Page 644: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 7

Image Quality setup into MIM (or 190) for Wet cameras: MIM (or 190) Parameters 160, 2180, 1120, 190

(see Note below) Curve Shape (Always Apply=Y/N)

3 (Y)

Contrast (Always Apply=Y/N)

0 (Y)

Max.Density (Always Apply=Y/N)

300 (Y)

PLUT=Y/N (not available on 190)

N

Note: reported setup was tested eg for 160 and tentatively is valid also for other cameras ie 2180, 1120, 190.

Page 645: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 8

More info on OEM Modality when connected to Wet cameras: Works the OEM Modality in Page-Mode? (Yes/No) No Note: see Page-Mode definition and matrixes into Kodak cameras setup catalog. Are Image Data lutted by the OEM Modality, ie Linear-in-Density LUT into Camera? (Yes/No)

No

Note: Linea-in-Density LUT into Camera means eg CurveShape=0,Dmax=3.00,Contrast=0. Which are the Image Quality parameters sent out by the OEM Modality: DICOM Parameters

Sent out by Modality (Yes/No)

Value sent out for 160, 2180, 1120,

190 Config. Information (CurveShape\Contrast)

Yes

CS435\CN0

Max. Density Yes 300 Magnification Yes CUBIC Smoothing No PLUT No Illumination (PLUT) No Reflective Ambient Light (PLUT)

No

Page 646: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: May ´05 9

Miscellaneous: Deviations in respect to the printer setup reported into Kodak Catalog: e.g. disable N-Event ie NeventReports=No (Always=Y) Known Problems or Limitations: Notes:

Page 647: Other OEM Setup Manuals

MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 1

Setup for MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGERS MeVis BreastCare Soft Copy Reading Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) .................................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

Page 648: Other OEM Setup Manuals

MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 2

MeVis BreastCare Soft Copy Reading via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: MeVis BreastCare SCR v1-2 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: in sw v1-2 Image Data lutted by Mevis, linear-in-Density LUT into Camera MeVis BreastCare SCR Setup: - into DICOM / Setup/ DICOM Setup set: - Entity Type: Printer=On, AEtitle=9410, IPaddr=accordingly, Port=1024 - Printer Setup: Printer Name=Kodak 8610, Dmax=350 - Printer Setup: Config.Info=LUT=0,5 - Printer Setup: Portrait matrix (Columns x Rows)=5024 x 6200 - Printer Setup: Landscape matrix (Columns x Rows)=6200 x 5024 - Printer Setup: Graylevel 16(12)=On (Off if 8600), 8=Off (On if 8600) - Printer Setup: Medium=Blue Film, Medium Size=8INx10IN 9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr= accordingly n SCP=8610, Copies=1, Contrast Table=5 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

MeVis BreastCareSoft Copy ReadingReview Console

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 649: Other OEM Setup Manuals

MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 3

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=6, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma Table=Xmittance, Image Size=Scale To Fit n Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 650: Other OEM Setup Manuals

MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 4

MeVis BreastCare Soft Copy Reading via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: MeVis BreastCare SCR v1-2 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Note: This setup is basically also valid for 25 PS computer Note: in sw v1-2 Image Data lutted by Mevis, linear-in-Density LUT into Camera MeVis BreastCare SCR Setup: - into DICOM / Setup/ DICOM Setup set: - Entity Type: Printer=On, AEtitle=8610, IPaddr=accordingly, Port=5040 - Printer Setup: Printer Name=Kodak 8610, Dmax=350 - Printer Setup: Config.Info=LUT=0,5 - Printer Setup: Portrait matrix (Columns x Rows)=5024 x 6200 - Printer Setup: Landscape matrix (Columns x Rows)=6200 x 5024 - Printer Setup: Graylevel 16(12)=On (Off if 8600), 8=Off (On if 8600) - Printer Setup: Medium=Blue Film, Medium Size=8INx10IN MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qual., 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even

MeVis BreastCareSoft Copy ReadingReview Console

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 651: Other OEM Setup Manuals

MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 5

n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y), Contrast (dry)=5 (Always=N), n Modality Group=1 (which corresponds to TFT/ULUT=upmsv3kp.w8u), n Conv.Group=1, Gamma Table= Linear in Density n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=scr n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma= Xmittance, Image Size=Scale To Fit, Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=255 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 652: Other OEM Setup Manuals

MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 6

MeVis BreastCare Soft Copy Reading via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: MeVis BreastCare SCR v1-2 Requirements: 8900 rev.E ie release 2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: in sw v1-2 Image Data lutted by Mevis, linear-in-Density LUT into Camera MeVis BreastCare SCR Setup: - into DICOM / Setup/ DICOM Setup set: - Entity Type: Printer=On, AEtitle=8900, IPaddr=accordingly, Port=5040 - Printer Setup: Printer Name=Kodak 8900, Dmax=350 - Printer Setup: Config.Info=LUT=Wrkstn2a.w87,1 - Printer Setup: Portrait matrix (Columns x Rows)=5056 x 6368 (for 8x10) - Printer Setup: Landscape matrix (Columns x Rows)=6368 x 5056 (for 8x10) - Printer Setup: Medium=Blue Film, Medium Size=8INx10IN - Printer Setup: Graylevel 16(12)=On, 8=Off - Printer Setup: Portrait matrix (Columns x Rows)=6368 x 7656 (for 10x12) - Printer Setup: Landscape matrix (Columns x Rows)=7656 x 6368 (for 10x12) - Printer Setup: Medium=Blue Film, Medium Size=10INx12IN 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any

MeVis BreastCareSoft Copy ReadingReview Console

DICOM Network

Kodak DryView 8900

Page 653: Other OEM Setup Manuals

MeVis BreastCare Mammography Soft Copy Reading with LASER IMAGER Products

Author: [email protected], Edition: November ́ 04 7

n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=Wrkstn2a.w87 (Always=N), Contrast=1 (Always=N), n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=scr

Page 654: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Planmeca Dental Systems ProMax/Proline/Dixi2/Dimax2 with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER......................................................................... 10 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER......................................................................... 12 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 14

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 160 LASER IMAGER .......................................................................... 16

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 2180 LASER PRINTER ....................................................................... 18

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Ektascan 1120 LASER PRINTER ....................................................................... 20

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8200 LASER IMAGER (1).................................................................... 22

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)............... 25

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ) (1) . 28

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER (1).................................................................... 31

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER (1).................................................................... 34

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ............................................................................................................ 37

n Kodak DryView 8900 LASER IMAGER......................................................................... 40 n Kodak DryView 8150 LASER IMAGER......................................................................... 42 n Kodak Color Medical Imager 1000 ................................................................................. 44

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 655: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8300] (note: set here the AE Title of the 8300) PORT_NUMBER=104 HOST_NAME= IP address of 8300 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8300 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=0, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,10 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=Off, Film Box=On Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=On

Planmeca Dimaxis workstation

Kodak DryView 8300

DICOM Network

Page 656: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Note: on application into Administration\Global Settings\Panoramic set Resolution=Normal to print Panoramic images Landscape with matrix 2424x1032 Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8300, Copies=1 and press OK: 8300 Setup: n on 8300 Operator Menu into Configure User set: n Density=16, Contrast=10, Sharp/Smooth=0 n on 8300 Service Menu into Configure User set:

n Modality Group=0

Page 657: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 190 rel. 1.7.29 Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [190] (note: set here the AE Title of the 190) PORT_NUMBER=5040 HOST_NAME= IP address of 190 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=190 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=NORMAL, Border=BLACK, Empty Image Density=BLACK Configuration Information=CS435\CN0\PD1.2 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print,

Planmeca Dimaxis workstation

DICOM Network

Kodak 190 camera

Page 658: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Default Printer AE: Select=190, Copies=1 and press OK 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type= RJ45

Page 659: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [9410] (note: set here the AE Title of the 9410) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=9410 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=11INX14IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0

Planmeca Dimaxis workstation

Kodak DryView 8500 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 660: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=9410, Copies=1 and press OK

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 661: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [9410] (note: set here the AE Title of the 9410) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=9410 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0

Planmeca Dimaxis workstation

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 662: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=9410, Copies=1 and press OK

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 663: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 9410 v1.6, 8100 v2.4.1 Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [9410] (note: set here the AE Title of the 9410) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=9410 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties:

Planmeca Dimaxis workstation

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 664: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=9410, Copies=1 and press OK

9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 665: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [9410] (note: set here the AE Title of the 9410) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=9410 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=0, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,10 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties:

Planmeca Dimaxis workstation

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 666: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Support PRINT JOB=Off, Prints Only 8 Bit Images=On Note: on application into Administration\Global Settings\Panoramic set Resolution=Normal to print Panoramic images Landscape with matrix 2424x1032 Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=9410, Copies=1 and press OK:

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 667: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [9410] (note: set here the AE Title of the 9410) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=9410 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=1, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,3 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off

PhilipsEasyVision / EasyRAD

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 668: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off (if 8600 On) Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=9410, Copies=1 and press OK

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=300, Contrast=3, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title= 9410, Port= 1024, Max Associations= 5 n on Device Setup, SCP PRINTERS, Registered Users:

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8610, Copies=1, Contrast Table=3, Max.Density=350 n Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=6, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1 n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 669: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM 200 v6.1, KELI 160 v5.2 Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [160] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=160 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=NORMAL, Border=BLACK, Empty Image Density=BLACK Configuration Information=CS435\CN0 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties:

Planmeca Dimaxis workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 670: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=160, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set:

n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Interpolation=Cubic, Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 671: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 2180 rel. 2.17H Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [2180] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=2180 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=NORMAL, Border=BLACK, Empty Image Density=BLACK Configuration Information=CS435\CN0 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties:

Planmeca Dimaxis workstation

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 camera

Page 672: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=2180, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set:

n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 673: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [1120] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=1120 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=NORMAL, Border=BLACK, Empty Image Density=BLACK Configuration Information=CS435\CN0 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties:

Planmeca Dimaxis workstation

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 camera

Page 674: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=1120, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set:

n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=Black (Always=N) n Interpolation=Cubic, Border Dmax=3.99 n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 675: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8200] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8200 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off

Planmeca Dimaxis workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak DryView 8200

Page 676: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8200, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set:

n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Blue n Media Info: Media=35x35cm, 4361x4247, 4157, Blue n Media Info: Media=11x14in, 3272x4361, 4271, Blue n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On n Formatting: Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20 n Formatting: Max Img Col=0, Max Img Row=0, n Formatting: Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify/Crop=On, Max Image Dmax=3.1 n SCU: Density Space= On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n at Keypad connected to MIM, press Menu, Service Menu, SCP Services: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N)

Page 677: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM / SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 678: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8500] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8500 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=11INX14IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Planmeca Dimaxis workstation

Page 679: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8500, Copies=1 and press OK MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N)

Page 680: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 681: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8700] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8700 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Planmeca Dimaxis workstation

Page 682: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8700, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N)

Page 683: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

n Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 684: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8100] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8100 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level:

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Planmeca Dimaxis workstation

Page 685: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8100, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set:

n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

Page 686: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 687: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8300] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8300 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=0, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,10 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Planmeca Dimaxis workstation

Page 688: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=On Note: on application into Administration\Global Settings\Panoramic set Resolution=Normal to print Panoramic images Landscape with matrix 2424x1032 Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8300, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add:

n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set:

n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=0 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

Page 689: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 690: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8610] (note: set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8610 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=1, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,3 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level:

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Planmeca Dimaxis workstation

Page 691: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off (if 8600 On) Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8610, Copies=1 and press OK MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=gsdfaa0p.w8u (Always=N), Contrast (dry)=3 (Always=N) n Modality Group=6, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

Page 692: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify: n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5) n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care n on 8610 Service Menu into Configure User set:

n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 693: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [8900] (note: set here the AE Title of the 8900) PORT_NUMBER=5040 HOST_NAME= IP address of 8900 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8900 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off

Planmeca Dimaxis workstation

DICOM Network

Kodak DryView 8900

Page 694: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8900, Copies=1 and press OK 8900 Setup: n on Configuration, System, Network: n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 695: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Planmeca Dimaxis rel. 3.1.2 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [DV8150] (note: set here the AE Title of the 8150) PORT_NUMBER=5040 HOST_NAME= IP address of 8150 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=DV8150 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=14INX17IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off

Planmeca Dimaxis workstation

DICOM Network

Kodak DryView 8150

Page 696: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

Note: on Dimaxis application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=DV8150, Copies=1 and press OK 8150 Setup: n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=11 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 697: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

Planmeca ProMax/Proline/Dixi2/Dimax2 via DICOM with Kodak Color Medical Imager 1000

Requirements: Planmeca Dimaxis rel. 3.2.0 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Planmeca Setup: - into file C:\Merge\Config\Mergecom.APP set: [CMI1000] (note: set here the AE Title of the CMI1000) PORT_NUMBER=5040 HOST_NAME= IP address of CMI1000 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=1000 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, Dimaxis will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=11, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,9 Preferred Image Sizes (Pixels): Panoramic: Width=0, Height=0, Cephalometric: Width=0, Height=0 Intraoral: Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=On Note: on Dimaxis application to print select image, press DICOM\DICOM Print,

Planmeca Dimaxis workstation

DICOM Network

Kodak CMI 1000

Page 698: Other OEM Setup Manuals

Planmeca Dental Systems with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

Default Printer AE: Select=1000, Copies=1 and press OK CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup: n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040 n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=11 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 699: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 1

Setup for Planmed Mammography CCD-Spot Imaging with LASER IMAGERS Planmed CCD-Spot Imaging Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGER (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGER (see also 8600) (1) ............................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 700: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 2

Planmed CCD-Spot Imaging via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Planmed DigiGuide v1.0.2 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Planmed Setup: - into file C:\Merge\Config\Mergecom.APP set: [9410] (note : set here the AE Title of the 9410) PORT_NUMBER=1024 HOST_NAME= IP address of 9410 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=9410 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, DigiGuide will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=1, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,3 Preferred Image Sizes (Pixels): Width=0, Height=0 Print Level:

Planmed MammographyCCD-Spot Imaging

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 701: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 3

Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off (if 8600 On) Note: on DigiGuide application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=9410, Copies=1 and press OK 9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr= accordingly n SCP=8610, Copies=1, Contrast Table=3 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma=Xmittance, Image Size=Scale To Fit,Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 702: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 4

Planmed CCD-Spot Imaging via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Planmed DigiGuide v1.0.2 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Planmed Setup: - into file C:\Merge\Config\Mergecom.APP set: [8610] (note : set here the AE Title of the MIM200) PORT_NUMBER=5040 HOST_NAME= IP address of MIM200 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8610 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, DigiGuide will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=1, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,3 Preferred Image Sizes (Pixels): Width=0, Height=0

Planmed MammographyCCD-Spot Imaging

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 703: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 5

Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off (if 8600 On) Note: on DigiGuide application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8610, Copies=1 and press OK MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qual., 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n Contrast (dry)=3 (Always=N) n Modality Group=6 (which corresponds to TFT/ULUT=gsdfaa0p.w8u) n Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Pola rity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off

Page 704: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 6

n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma= Xmittance, Image Size=Scale To Fit, Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 705: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 7

Planmed CCD-Spot Imaging via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: Planmed DigiGuide v1.0.2 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Planmed Setup: - into file C:\Merge\Config\Mergecom.APP set: [8900] (note : set here the AE Title of the 8900) PORT_NUMBER=5040 HOST_NAME= IP address of 8900 SERVICE_LIST= Print_Service_List - on application into Administration\DICOM Settings\Applications Default Printer AE: Select=8900 and into Setup set: Note: if a DICOM parameter is set here to DEFAULT, DigiGuide will not send it Film Session: Priority=HIGH, Medium Type=BLUE FILM, Film Destination=PROCESSOR Film Box: Film Orientation=PORTRAIT, Film Size=8INX10IN, Magnification Type=CUBIC Smoothing Type=15, Border Density=BLACK, Empty Image Density=BLACK Configuration Information=LUT=0,3 Preferred Image Sizes (Pixels): Width=0, Height=0 Print Level: Film Session=On, Film Box=Off Other Properties: Support PRINT JOB=Off, Prints Only 8 Bit Images=Off

Planmed MammographyCCD-Spot Imaging

DICOM Network

Kodak DryView 8900

Page 706: Other OEM Setup Manuals

Planmed Mammography CCD-Spot Imaging with LASER IMAGER Products

Author: [email protected], Edition: November ´04 8

Note: on DigiGuide application to print select image, press DICOM\DICOM Print, Default Printer AE: Select=8900, Copies=1 and press OK 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=gsdfaa0p.w8u (Always=N), Contrast=3 (Always=N) n Smoothing Type=15 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=planm

Page 707: Other OEM Setup Manuals

Planmed Mammography FFDM with LASER IMAGER Products

Author: [email protected], Edition: November ´04 1

Setup for Planmed Mammography FFDM with LASER IMAGERS Planmed FFDM Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGER (see also 8600) .................................................................................................................. 2

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGER (see also 8600) (1) ............................................................................................................. 4

n Kodak DryView 8900 LASER IMAGER with Mammography Accessory.......................... 6

1 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 708: Other OEM Setup Manuals

Planmed Mammography FFDM with LASER IMAGER Products

Author: [email protected], Edition: November ´04 2

Planmed FFDM via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: Planmed FFDM Nuance SoftView v5.3beta Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Planmed Setup: - into Service Tool / HardCopy Server select Printer=ISGDICOMKodakDPS, - Type=515, IP=accordingly, Port=1024, Title=9410 9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr= accordingly n SCP=8610, Copies=1, Contrast Table=3 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=Yes, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=3, Border Density=0

Planmed MammographyFFDM

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 709: Other OEM Setup Manuals

Planmed Mammography FFDM with LASER IMAGER Products

Author: [email protected], Edition: November ´04 3

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma=Xmittance, Image Size=Scale To Fit,Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 710: Other OEM Setup Manuals

Planmed Mammography FFDM with LASER IMAGER Products

Author: [email protected], Edition: November ´04 4

Planmed FFDM via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Planmed FFDM Nuance SoftView v5.3beta Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Planmed Setup: - into Service Tool / HardCopy Server select Printer=ISGDICOMKodakDPS, - Type=515, IP=accordingly, Port=5040, Title=8610 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qual., 8610 (or 8600), Set: n General: Log.Name=8610 (or 8600) n General: Database Name=8610 (or 8600), Model=8610 (or 8600), Memory=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600), Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On

Planmed MammographyFFDM

Kodak DryView 8610

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 711: Other OEM Setup Manuals

Planmed Mammography FFDM with LASER IMAGER Products

Author: [email protected], Edition: November ´04 5

n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n Contrast (dry)=3 (Always=N) n Modality Group=6 (which corresponds to TFT/ULUT=gsdfaa0p.w8u) n Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=Y) n Smoothing Type=1 (Always=Y), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma= Xmittance, Image Size=Scale To Fit, Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 712: Other OEM Setup Manuals

Planmed Mammography FFDM with LASER IMAGER Products

Author: [email protected], Edition: November ´04 6

Planmed FFDM via DICOM with Kodak DryView 8900 LASER IMAGER with Mammography Accessory

Requirements: Planmed FFDM Nuance SoftView v5.3beta Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Planmed Setup: - into Service Tool / HardCopy Server select Printer=ISGDICOMKodakDPS, - Type=515, IP=accordingly, Port=5040, Title=8900 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr= accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is ON

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4

Planmed MammographyFFDM

DICOM Network

Kodak DryView 8900

Page 713: Other OEM Setup Manuals

Planmed Mammography FFDM with LASER IMAGER Products

Author: [email protected], Edition: November ´04 7

n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=gsdfaa0p.w8u (Always=N), Contrast=3 (Always=N) n Smoothing Type=15 (Always=N), Image Dmin=0.00 (Always=N), n Image Dmax=3.50 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Mammo Blue Film (Always=Y) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=planm

Page 714: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for QR CT dental system NewTom 9000 / 3G with LASER IMAGERS Connection via DICOM: n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) ..................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) ..................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak Digital Science 969 HQ LASER IMAGER .......................................................... 2 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER......................................................................... 2 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 2 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual).................... 2 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Digital Science 969 HQ LASER IMAGER...................................................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER ............................................................................... 5 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER ............................................................................... 5 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) ........................................................................................................................... 5

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8100 LASER IMAGER......................................................................... 5

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8300 LASER IMAGER......................................................................... 5

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) ................................................................................................................. 5

n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 8 n Kodak DryView 8900 LASER IMAGER......................................................................... 10 n Kodak DryView 8150 LASER IMAGER......................................................................... 12 n Kodak Color Medical Imager 1000 ................................................................................. 14

Page 715: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

QR CT dental NewTom 9000 / 3G via DICOM with Kodak DV8700, DV8500, DV8200 and 969 HQ LASER IMAGER

Requirements: QR NewTom 9000 / 3G CT dental system DLL-DICOM v1.0.0.5 Requirements: MIM200 v6.1, 9410 v1.6 Requirements: 8200 v3.5, 8500 v1.34, 8700 v1.34, 969 v5.2 Note: 8200 only with MIM200 in front, all other cameras with MIM200 and 9410 Note: The below setup is basically also valid for 8200, 8800/8700 Dual, 8500 Plus,

8800/8500 Dual and 969 cameras by basically using the correspondent Model into MIM200 Destination or into 9410 Local Printers

Note: on QR only a DICOM camera could be installed Note: 8700 matrix 14x17=4096x5220 ie 319.49 x 407.16 mm Note: 8500 matrix 11x14=3380x4280 ie 263.64 x 333.84 mm Note: 8200 matrix 14x17=4360x5220 ie 340.08 x 407.16 mm Note: 8200 matrix 14x14=4360x4244 ie 340.08 x 331.03 mm Note: 8200 matrix 11x14=3272x4360 ie 255.22 x 340.08 mm Note: 969 matrix 14x17=4096x4992 ie 335.87 x 409.34 mm Note: 969 matrix 11x14=3020x3960 ie 247.64 x 324.72 mm Note: 969 matrix 8x10=2076x2788 ie 170.23 x 228.62 mm QR Setup: n into Start/Programs/MedStation 3.5/Printer Server Configuration/Configuration n set Spool path=C:\MEDST35\PRNSRV\SPOOL, Sleep=1, Hospital=QR, n Printer Name=Kodak, Show Monitor=On, Enable log=On n into Start/Programs/MedStation 3.5/Printer Server Configuration/Protocol set: n Protocol=Dicom 3, Address=accordingly, n if MIM200: Port=5040, Called AE Title=8700, n if 9410: Port=1024, Called AE Title=9410, n Calling AE Title=QR_DCMPRN1 n Save n into QR Application enter in Service Mode pressing CTRL-ALT-SHIFT-ESC n under File/Print Setup choose 3M protocol & DICOM

DICOM Network

Cable:Crossed Network 82002 x Fiber 8500,8700,969QR NewTom CT

Dental SystemsKodak cameras:- 8200- 8500 (and 8500 Dual)- 8700 (and 8700 Dual)- 969

Kodak DICOM Print Server:- MIM 200- 9410

Page 716: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

n select DICOM Printer n for 14x17 Page Size (mm) X=319, Y=407, Page Size (pixel) X=4096, Y=5220 n for other filmsizes see correspondent data above reported n with Explorer look for NNT directory and open Dicomprn.ini and set: n NUMCOPIES=1, PRIORITY=MEDIUM, MEDIUM=BLUE FILM, n DESTINATION=PROCESSOR, SESSION=MedStation film, n ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=NONE, SMOOTHING=0, n MAXDENS=300, MINDENS=21 n CONFIGINFO=LUT=Pmsv3k.w87,9 n IMAGEFILE=C:\temp\printspool/F0000002.dcm n IMAGEROWS=5220, IMAGECOLS=4096 MIM200 Setup: n on Configure, Network:

n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, eg 8700, Set: n accept all defaults by pressing Next and at very end Finish. n General: Log.Name=eg 8700, IPAddr=100.100.100.40 (for 8200) n General: Database Name=eg 8700, Model=eg 8700, Memory=32 n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n accept all defaults by pressing Next and at very end pressing Finish

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=Y) n Smoothing Type=0 (Always=Y), Image Dmax=3.00 (Always=Y) n Image Dmin=0.00 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=eg 8700, Model=eg 8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=eg 8700, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users:

Page 717: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=eg 8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 / 8500 / 969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60 8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM / SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 718: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

QR CT dental NewTom 9000 / 3G via DICOM with Kodak DV8100, DV8300, DV8600 and DV8610 LASER IMAGER

Requirements: QR NewTom 9000 / 3G CT dental system DLL-DICOM v1.0.0.5 Requirements: MIM200 v6.1, 9410 v1.6 Requirements: 8100 v2.4.1, 8300 v4.9.1, 8600 v2.5, 8610 v2.4 Note: The below setup is basically also valid for 8300, 8600 and 8610

cameras by basically using the correspondent Model into MIM200 Destination or into 9410 Local Printers

Note: on QR only a DICOM camera could be installed Note: 8100 matrix 14x17=4096x5216 ie 319.49 x 406.85 mm Note: 8300 matrix 8x10 Portrait=2256x2676 ie 191.76 x 227. mm46 Note: 8300 matrix 8x10 Landscape=2736x2136 ie 232.56 x 181.5 mm6 Note: 8600/8610 matrix 8x10=5024x6200 ie 194.68 x 240.25 mm QR Setup: n into Start/Programs/MedStation 3.5/Printer Server Configuration/Configuration n set Spool path=C:\MEDST35\PRNSRV\SPOOL, Sleep=1, Hospital=QR, n Printer Name=Kodak, Show Monitor=On, Enable log=On n into Start/Programs/MedStation 3.5/Printer Server Configuration/Protocol set: n Protocol=Dicom 3, Address=accordingly, n if MIM200: Port=5040, Called AE Title=8100, n if 9410: Port=1024, Called AE Title=9410, n Calling AE Title=QR_DCMPRN1 n Save n into QR Application enter in Service Mode pressing CTRL-ALT-SHIFT-ESC n under File/Print Setup choose 3M protocol & DICOM n select DICOM Printer n for 14x17 Page Size (mm) X=319, Y=407, Page Size (pixel) X=4096, Y=5216 n for other filmsizes see correspondent data above reported n with Explorer look for NNT directory and open Dicomprn.ini and set: n NUMCOPIES=1, PRIORITY=MEDIUM, MEDIUM=BLUE FILM, n DESTINATION=PROCESSOR, SESSION=MedStation film,

DICOM Network

Copper Cable

Control 9-pininto 422 plug

Data 37-pin

QR NewTom CTDental Systems

Kodak cameras:- 8100- 8300- 8600- 8610

Kodak DICOM Print Server:- MIM 200- 9410

Page 719: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

n ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=NONE, SMOOTHING=0, n MAXDENS=300, MINDENS=21 n CONFIGINFO=LUT=Pmsb.w87,9 n (if 8300: CONFIGINFO=LUT=u1_109s.w8u,10) n (if 8600/8610: CONFIGINFO=LUT=gsdfaa0p.w8u,3) n IMAGEFILE=C:\temp\printspool/F0000002.dcm n IMAGEROWS=5216, IMAGECOLS=4096 MIM200 Setup: n on Configure, Network:

n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, eg 8100, Set: n accept all defaults by pressing Next and at very end Finish. n General: Log.Name=eg 8100 n General: Database Name=eg 8100, Model=eg 8100, Memory=32 n Output Params: Pixel=12 (8 if 8300, 8600) n accept all defaults by pressing Next and at very end pressing Finish

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=Y) n Smoothing Type=0 (Always=Y), Image Dmax=3.00 (Always=Y) n Image Dmin=0.00 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off n (if 8300: TFT= u1_109s.w8u (Always=Y), Contrast=10 (Always=Y)) n (if 8600/8610: Contrast=3 (Always=Y), Dmax=3.50 (Always=Y), n Modality Group=6 (which corresponds to TFT/ULUT=gsdfaa0p.w8u), n Smoothing Type=1 (Always=Y), Conv.Group=1, Gamma=Transmittance)

9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=eg 8100, Model=eg 8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8300,8600), Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831, Interp Num=2 n Max.Density=300, Contrast=6, Border Density=0, TFT/ULUT Emulation=On n Installed TFT/ULUT=Ver693c0.w87 (upmsv3k.w8u if 8300) on Device Setup, SCP PRINTERS, Current Providers: n Printer=eg 8100, AE Title=9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users:

Page 720: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=eg 8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 n (if 8300: Contrast Table=10, TFT/ULUT=u1_109b.w8u) n (if 8600/8610: Contrast Table=3, Max.Density=350, Smoothing=1, n Gamma=Transmittance, Contrast Group=6, Kernel Group=1) 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even 8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1 8600 / 8610 Setup: n on Operator Menu into Test Menu, Software Version, verify:

n if 8610: Imager=2.4, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 721: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

QR CT dental NewTom 9000 / 3G via DICOM with Kodak 160, 1120, 2180 and 190 LASER IMAGER

Requirements: QR NewTom 9000 / 3G CT dental system DLL-DICOM v1.0.0.5 Requirements: MIM200 v6.1 Requirements: 160 v7.2, 1120 v2.40/032, 2180 v2.17H, 190 v1.7.29 Note: 190 is a built-in DICOM, therefore MIM200 is not needed Note: The below setup is basically also valid for 1120 and 2180 cameras by basically

using the correspondent Model into MIM200 Destination Note: on QR only a DICOM camera could be installed Note: 160 matrix 14x17=4360x5348 ie 340.08 x 417.14 mm Note: 190 matrix 14x17=4096x5120 ie 327.68 x 409.60 mm Note: 1120 matrix 14x17=4096x5132 ie 327.68 x 410.56 mm Note: 1120 matrix 14x14=4096x4108 ie 327.68 x 328.64 mm Note: 1120 matrix 11x14=4096x3232 ie 327.68 x 258.56 mm Note: 1120 matrix 8x10=2304x2900 ie 184.32 x 232.00 mm Note: 2180 matrix 14x17=4096x5156 ie 323.58 x 407.32 mm Note: 2180 matrix 14x14=4096x4132 ie 323.58 x 326.43 mm Note: 2180 matrix 11x14=3236x4132 ie 255.64 x 326.43 mm Note: 2180 matrix 8x10=2286x2836 ie 180.59 x 224.04 mm QR Setup: n into Start/Programs/MedStation 3.5/Printer Server Configuration/Configuration n set Spool path=C:\MEDST35\PRNSRV\SPOOL, Sleep=1, Hospital=QR, n Printer Name=Kodak, Show Monitor=On, Enable log=On n into Start/Programs/MedStation 3.5/Printer Server Configuration/Protocol set: n Protocol=Dicom 3, Address=accordingly, Port=5040, Called AE Title=160, n Calling AE Title=QR_DCMPRN1 n Save n into QR Application enter in Service Mode pressing CTRL-ALT-SHIFT-ESC n under File/Print Setup choose 3M protocol & DICOM n select DICOM Printer n for 14x17 Page Size (mm) X=340, Y=417, Page Size (pixel) X=4360, Y=5348 n for other filmsizes see correspondent data above reported

QR NewTom CTDental Systems

DICOM Network

Kodak cameras:- 160- 1120- 2180- 190 (no MIM200)

Kodak MIM 200

Cable:Crossed Network 160Fiber 1120, 2180

Page 722: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n with Explorer look for NNT directory and open Dicomprn.ini and set: n NUMCOPIES=1, PRIORITY=MEDIUM, MEDIUM=BLUE FILM, n DESTINATION=PROCESSOR, SESSION=MedStation film, n ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=NONE, SMOOTHING=NORMAL, n MAXDENS=300, MINDENS=21 n CONFIGINFO=CS435\CN0 n IMAGEFILE=C:\temp\printspool/F0000002.dcm n IMAGEROWS=5348, IMAGECOLS=4360 MIM200 Setup: n on Configure, Network:

n Computer Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 160 or 1120 or 2180, Set: n General: Log.Name=eg 160, Database Name=eg 160 n General: Model=eg 160, IPAddr=100.100.100.30 (for 160) n General: Memory=20 (1120) or 24 (2180), Node ID=6 or accordingly n accept all defaults by pressing Next and at very end pressing Finish

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Interpolation=Cubic, Image Dmax=3.00 (Always=Y) n Image Dmin=0.00 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Text Box Relocation=None (Always=N) n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed 1120 / 2180 Setup: Optical Interface board configures automatically, no setup needed 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Contrast Pivot Density=1.2 n Curve Shape=same as used into MIM, Contrast=same as used into MIM n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 723: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

QR CT dental NewTom 9000 / 3G via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: QR NewTom 9000 / 3G CT dental system DLL-DICOM v1.0.0.5 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: on QR only a DICOM camera could be installed Note: 8900 matrix 14x17=4488x5464 ie 350.75 x 427.03 mm Note: 8900 matrix 14x14=4488x4488 ie 350.75 x 350.75 mm Note: 8900 matrix 11x14=3514x4488 ie 274.63 x 350.75 mm Note: 8900 matrix 10x12=3184x3828 ie 248.84 x 299.17 mm Note: 8900 matrix 8x10=2528x3184 ie 197.57 x 248.84 mm QR Setup: n into Start/Programs/MedStation 3.5/Printer Server Configuration/Configuration n set Spool path=C:\MEDST35\PRNSRV\SPOOL, Sleep=1, Hospital=QR, n Printer Name=Kodak, Show Monitor=On, Enable log=On n into Start/Programs/MedStation 3.5/Printer Server Configuration/Protocol set: n Protocol=Dicom 3, Address=accordingly, Port=5040, Called AE Title=8900, n Calling AE Title=QR_DCMPRN1 n Save n into QR Application enter in Service Mode pressing CTRL-ALT-SHIFT-ESC n under File/Print Setup choose 3M protocol & DICOM n select DICOM Printer n for 14x17 Page Size (mm) X=351, Y=427, Page Size (pixel) X=4488, Y=5464 n for other filmsizes see correspondent data above reported n with Explorer look for NNT directory and open Dicomprn.ini and set: n NUMCOPIES=1, PRIORITY=MEDIUM, MEDIUM=BLUE FILM, n DESTINATION=PROCESSOR, SESSION=MedStation film, n ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=REPLICATE, SMOOTHING=0, n MAXDENS=300, MINDENS=21 n CONFIGINFO=LUT=Pmsv3k.w87,9 n IMAGEFILE=C:\temp\printspool/F0000002.dcm n IMAGEROWS=5464, IMAGECOLS=4488

QR NewTom CTDental Systems

DICOM Network

Kodak DryView 8900

Page 724: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, System, Software License: n License Status=Mammo Key is OFF

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=Y), Contrast=9 (Always=Y) n Smoothing Type=0 (Always=Y), Image Dmax=3.00 (Always=Y) n Image Dmin=0.00 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=Y) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 725: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

QR CT dental NewTom 9000 / 3G via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: QR NewTom 9000 / 3G CT dental system DLL-DICOM v1.0.0.5 Requirements: 8150 v1.0.2.b04 (ie DRE v1.0.2.b04, MIM v5.7.b8) Note: on QR only a DICOM camera could be installed Note: 8150 matrix 14x17=4438x5390 ie 346.8 x 421.1 mm Note: 8150 matrix 14x14=4438x4414 ie 346.8 x 344.9 mm Note: 8150 matrix 11x14=3440x4438 ie 268.7 x 346.8 mm QR Setup: n into Start/Programs/MedStation 3.5/Printer Server Configuration/Configuration n set Spool path=C:\MEDST35\PRNSRV\SPOOL, Sleep=1, Hospital=QR, n Printer Name=Kodak, Show Monitor=On, Enable log=On n into Start/Programs/MedStation 3.5/Printer Server Configuration/Protocol set: n Protocol=Dicom 3, Address=accordingly, Port=5040, Called AE Title=DV8150, n Calling AE Title=QR_DCMPRN1 n Save n into QR Application enter in Service Mode pressing CTRL-ALT-SHIFT-ESC n under File/Print Setup choose 3M protocol & DICOM n select DICOM Printer n for 14x17 Page Size (mm) X=347, Y=421, Page Size (pixel) X=4438, Y=5390 n for other filmsizes see correspondent data above reported n with Explorer look for NNT directory and open Dicomprn.ini and set: n NUMCOPIES=1, PRIORITY=MEDIUM, MEDIUM=BLUE FILM, n DESTINATION=PROCESSOR, SESSION=MedStation film, n ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=NONE, SMOOTHING=0, n MAXDENS=300, MINDENS=21 n CONFIGINFO=LUT=Pmsb.w87,9 n IMAGEFILE=C:\temp\printspool/F0000002.dcm n IMAGEROWS=5390, IMAGECOLS=4438 8150 Setup:

DICOM Network

Kodak DryView 8150

QR NewTom CTDental Systems

Page 726: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n on Configuration, System, Network: n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT=Pmsb.w87 (Always=Y), Contrast=9 (Always=Y) n Smoothing Type=0 (Always=Y), Image Dmax=3.00 (Always=Y) n Image Dmin=0.00 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=No, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 727: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

QR CT dental NewTom 9000 / 3G via DICOM with Kodak Color Medical Imager 1000

Requirements: QR NewTom 9000 / 3G CT dental system DLL-DICOM v1.0.0.5 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: on QR only a DICOM camera could be installed Note: CMI 1000 matrix Letter =2508x2954 ie 203.2 x 239.3 mm Note: CMI 1000 matrix A4 =2508x3134 ie 203.2 x 253.9 mm QR Setup: n into Start/Programs/MedStation 3.5/Printer Server Configuration/Configuration n set Spool path=C:\MEDST35\PRNSRV\SPOOL, Sleep=1, Hospital=QR, n Printer Name=Kodak, Show Monitor=On, Enable log=On n into Start/Programs/MedStation 3.5/Printer Server Configuration/Protocol set: n Protocol=Dicom 3, Address=accordingly, Port=5040, Called AE Title=CMI1000, n Calling AE Title=QR_DCMPRN1 n Save n into QR Application enter in Service Mode pressing CTRL-ALT-SHIFT-ESC n under File/Print Setup choose 3M protocol & DICOM n select DICOM Printer n for 8x10 if Letter n Page Size (mm) X=203, Y=239, Page Size (pixel) X=2508, Y=2954 n for 8x10 if A4 see correspondent data above reported n with Explorer look for NNT directory and open Dicomprn.ini and set: n NUMCOPIES=1, PRIORITY=MEDIUM, MEDIUM=BLUE FILM, n DESTINATION=PROCESSOR, SESSION=MedStation film, n ORIENTATION=PORTRAIT, SIZEID=8INX10IN n MAGNTYPE=NONE, SMOOTHING=0, n MAXDENS=300, MINDENS=21 n CONFIGINFO=LUT=Pmsv3k.w87,9 n IMAGEFILE=C:\temp\printspool/F0000002.dcm n IMAGEROWS=2954, IMAGECOLS=2508 CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y):

DICOM Network

QR NewTom CTDental Systems

Kodak CMI 1000

Page 728: Other OEM Setup Manuals

QR CT dental system NewTom 9000 / 3G with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=0 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 729: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: November ́ 04 1

Specific Setup for Sectra Mammography MicroDose with LASER IMAGERS OEM Data Manufacturer Sectra Modality Mammography Model MicroDose Mammography sw version IDS5/mx V9.1 Implement. Class UID 1.2.752.24.3.3.25.7 Implement. Version Name WIPRISCU_9_10 Kodak Data DICOM-interface MIM internal / external or 9410 as below reported DICOM-intf sw version as below reported Printer model All cameras as below reported Printer sw version as below reported What’s new: The setup of a Kodak printer for a given OEM Modality was split in 2 separate documents: - the generic Setup Catalog for Kodak Cameras - the specific Setup Manual for a given OEM Modality

************* the generic Setup Catalog for Kodak Cameras: the Setup Catalog for Kodak Cameras contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Setup Catalog for Kodak Cameras

(ie go to the Setup Catalog doc and do that first, then come back here and finish install as per this Specific Setup Manual doc). ************ the specific Setup Manual for a given OEM Modality: the Setup Manual for a given OEM Modality contains that part of a printer installation which is Specific to that particular OEM Modality to be connected, ie the OEM console Settings and the printer Image Quality parameters. Therefore, as second and final step, setup the printer as per the indications reported here into the Setup Manual for that particular OEM Modality. Note that the Setup Manual has 2 sections ie the DryView section and the Wet section.

Page 730: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: November ́ 04 2

What’s inside this document: n OEM Modality Setup (ie how to configure,into the OEM console,the Kodak printer)....... 2 n DryView correspondance with Kodak Setup Catalog for DryView cameras..................... 3 n Image Quality setup into MIM (or 9410) for DryView cameras .................................. 4 n More info on OEM Modality when connected to DryView cameras.................................... 5 n Wet correspondance with Kodak Setup Catalog for Wet cameras...................................... 6 n Image Quality setup into MIM (or 190) for Wet cameras.................................................... 7 n More info on OEM Modality eg Page-Mode and IQ parameters sent out by OEM ............. 8 n Miscellaneous: Deviations from Kodak Setup Catalog / Known Problems / Notes............... 9 OEM Modality Setup ie how to configure into the OEM console the Kodak printer: Note: MIM setup is basically also valid for 9410 by using AE=9410, Port=1024 Note: 8900 8x10 parameters: Resolution <5056>, Size <197:248> Note: 8900 10x12 parameters: Resolution <6368>, Size <248:299> Sectra Setup: n into C:\Program Files\Sectra\IDS5\config\local_config\_all_\general\def n very carefully edit the file dicom_printer.def to configure 8610 printer. n copy and paste an existing printer and set parameters as per below example KODAK_8610_8x10 { node <IP-address accordingly> # Must be configured port <5040> # Must be configured Label <8610> # Must be configured called_app_title <8610> copies <1> priority <MED> medium_type <BLUE FILM> film_destination <PROCESSOR> film_orientation <PORTRAIT> film_size <8INX10IN> magnification_type <NONE> max_density <350> configuration_information <LUT=0,3> border_density <BLACK> empty_image_density <BLACK> trim <NO> polarity <NORMAL> Get_all_printer_status <1> Resolution <5024> Size <194:239>

Page 731: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: November ́ 04 3

}

DryView section: Setup for Kodak DryView cameras ie 8900, 8700, 8610, 8600, 8500, 8300, 8200, 8150, 8100 Correspondance with Kodak Setup Catalog for DryView cameras: Note: the Kodak Setup Catalog contains that part of a printer installation which is Generic, ie common to all DICOM connections independently from the Specific modality connected. Therefore, as first step, setup the printer as per the correspondent page of the Kodak Setup Catalog, and then, as second and final step, setup the Image Quality parameters as per the Setup Manual for the Specific OEM Modality here below reported. MIM (inside printer) 8900 into Kodak catalog see Setup as per page

19

MIM sw version 5.6.b5 Printer sw version Rev.E ie 2.11 MIM external 8610 (8600) into Kodak catalog see Setup as per page

18

MIM sw version 6.1 Printer sw version 2.4 (2.5) 9410 external 8610 (8600) into Kodak catalog see Setup as per page

10

9410 sw version 1.6 Printer sw version 2.4 (2.5)

Page 732: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: November ́ 04 4

Image Quality setup into MIM (or 9410) for DryView cameras: MIM (or 9410) Parameters

8900 8610, 8600

TFT/ULUT (8610 Modality/Contrast Group) (Always Apply=Y/N)

gsdfaa0p.w8u

(Y)

(gsdfaa0p.w8u) 6

Contrast (Always Apply=Y/N)

3 (Y)

3 (Y)

Max.Density (Always Apply=Y/N)

350 (Y)

350 (Y)

Smoothing (Always Apply=Y/N)

0 (N)

1 (Y)

Presentation ie PLUT=Y/N (not available on 9410)

N N

8610 Convolution / Kernel Group Not available 1 8610 Gamma Table Not available Transmittance

Page 733: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: November ́ 04 5

More info on OEM Modality when connected to DryView cameras:

Works the OEM Modality in Page-Mode? (Yes/No) Yes Note: see Page-Mode definition and matrixes into Kodak cameras setup catalog. Are Image Data lutted by the OEM Modality, ie Linear-in-Density LUT into Camera? (Yes/No)

No

Note: Linea-in-Density LUT into Camera means eg TFT=Wrkstn2a.w87, Dmax=3.00, C=2. Which are the Image Quality parameters sent out by the OEM Modality: DICOM Parameters

Sent out by Modality (Yes/No)

Value sent out for 8900

Value sent out for 8610, 8600

Config. Information (LUT=TFT,Contrast)

Yes

LUT=0,3

LUT=0,3

Max. Density Yes 350 350 Magnification Yes CUBIC CUBIC Smoothing No PLUT No Illumination (PLUT) No Reflective Ambient Light (PLUT)

No

Page 734: Other OEM Setup Manuals

Specific Setup Manual for a given OEM Modality via DICOM with Kodak cameras

Author: [email protected], Edition: November ́ 04 6

Miscellaneous: Deviations in respect to the printer setup reported into Kodak Catalog: e.g. disable N-Event ie NeventReports=No (Always=Y) Known Problems or Limitations: Notes:

Page 735: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Sirona workstation Sidexis with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1) ................ 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (1) ................ 5 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1).......................................................................... 7 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1).......................................................................... 9 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ...................................................................................................................... 11

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak Digital Science 969 HQ LASER IMAGER (1) ..................................................... 13

n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 15 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2) ..................................................................... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2) .................................................................. 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2) .................................................................. 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (2,3).................................................................. 22 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (2,3) ............ 24 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (2,3) ............ 26 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (2,3).................................................................. 28 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (2,3).................................................................. 30 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (2,3) .......................................................................................................... 32

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Digital Science 969 HQ LASER IMAGER (2,3)............................................... 34

n Kodak DryView 8900 LASER IMAGER......................................................................... 36 n Kodak DryView 8150 LASER IMAGER......................................................................... 38 n Kodak Color Medical Imager 1000 ................................................................................. 40

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.5.1. 2 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 3 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 736: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Sidexis platform via DICOM with Kodak DryView 8300 LASER IMAGER

SironaDental SystemsSidexis platform

Kodak DryView 8300

DICOM Network

Requirements: Sirona Sidexis platform v5.5 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: 8300 Portrait matrix 8x10=2256x2676 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8300, Address=accordingly, Port=104, Called AE=K8300 n MatrixX=2736, MatrixY=2136, ResPrinter=300, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=LANDSCAPE, SIZEID=8INX10IN n MAGNTYPE=CUBIC, SMOOTHING=0, MAXDENS=300 n CONFIGINFO=LUT=0,10 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=0 n on 8300 Service Menu into Configure User set:

n Modality Group=0

Page 737: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Sidexis platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

SironaDental SystemsSidexis platform

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Sirona Sidexis platform v5.5, 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8500, Address=accordingly, Port=1024, Called AE=9410 n MatrixX=3380, MatrixY=4280, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=11INX14IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users:

Page 738: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 739: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

Sidexis platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

SironaDental SystemsSidexis platform

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Sirona Sidexis platform v5.5, 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into 9410 Local Printers Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8700, Address=accordingly, Port=1024, Called AE=9410 n MatrixX=4096, MatrixY=5220, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users:

Page 740: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 741: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

Sidexis platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

SironaDental SystemsSidexis platform

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Sirona Sidexis platform v5.5, 9410 v1.6, 8100 v2.4.1 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8100, Address=accordingly, Port=1024, Called AE=9410 n MatrixX=4096, MatrixY=5216, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 9410 Setup:

on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title=9410, Port=1024, Max Associations=5

on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low

Page 742: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 743: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

Sidexis platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

SironaDental SystemsSidexis platform

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Sirona Sidexis platform v5.5 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: 8300 Portrait matrix 8x10=2256x2676 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8300, Address=accordingly, Port=1024, Called AE=9410 n MatrixX=2736, MatrixY=2136, ResPrinter=300, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=LANDSCAPE, SIZEID=8INX10IN n MAGNTYPE=CUBIC, SMOOTHING=0, MAXDENS=300 n CONFIGINFO=LUT=0,10 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u

Page 744: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=0 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 745: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

Sidexis platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

SironaDental SystemsSidexis platform

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Sirona Sidexis platform v5.5 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8610, Address=accordingly, Port=1024, Called AE=9410 n MatrixX=6200, MatrixY=5024, ResPrinter=655, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=LANDSCAPE, SIZEID=8INX10IN n MAGNTYPE=CUBIC, SMOOTHING=4, MAXDENS=300 n CONFIGINFO=LUT=0,5 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8610, Model=8600/8610, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT=don’t care n Max.Density=300, Contrast=5, Border Density=0

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8610, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly

Page 746: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

n SCP=8610, Copies=1, Contrast Table=5, Max.Density=300 n Border Density=0, Mag.Type=8, Smoothing=4 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Gamma Table=Linear in Transmittance, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=11, Contrast=5, Sharp/Smooth=1, Film Layout: 1:1P, 2:1P, 4:1P, 6:1P n Gamma Table=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 747: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

Sidexis platform via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak Digital Science 969 HQ LASER IMAGER

SironaDental SystemsSidexis platform

Kodak 9410 PACS Link

DICOM Network

Fiber Cable

Fiber Cable

3 M H Q L a s e r I m a g e r

Kodak M969 HQ

Requirements: Sirona Sidexis platform v5.5, 9410 v1.6, 969 v5.2 Note: other HQ matrixes 11x14=3020x3960, 8x10=2076x2788 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 969, Address=accordingly, Port=1024, Called AE=9410 n MatrixX=4096, MatrixY=4992, ResPrinter=311.5, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=969, Model=969, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=969, AE Title=9410, Port=1024, Max Associations=5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle=accordingly, SCU IPAddr=accordingly n SCP=969, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2

Page 748: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 749: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

Sidexis platform via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

SironaDental SystemsSidexis platform

DICOM Network

Kodak 190 camera

Requirements: Sirona Sidexis platform v5.5, 190 v1.7.29 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 190, Address=accordingly, Port=5040, Called AE=K190 n MatrixX=4096, MatrixY=5120, ResPrinter=317.5, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=NORMAL, MAXDENS=300 n CONFIGINFO=CS435\CN0 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 750: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

SironaDental SystemsSidexis platform

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Requirements: Sirona Sidexis platform v5.5 Requirements: MIM200 v6.1, KELI 160 v7.2 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 160, Address=accordingly, Port=5040, Called AE=K160 n MatrixX=4360, MatrixY=5348, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=NORMAL, MAXDENS=300 n CONFIGINFO=CS435\CN0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Page 751: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e. 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 752: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

SironaDental SystemsSidexis platform

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Requirements: Sirona Sidexis platform v5.5 Requirements: MIM200 v6.1, 2180 v2.17H Note: other 2180 matrixes 14x14=4096x4132, 11x14=3236x4132, 8x10=2286x2836 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 2180, Address=accordingly, Port=5040, Called AE=K2180 n MatrixX=4096, MatrixY=5156, ResPrinter=321.5, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=NORMAL, MAXDENS=300 n CONFIGINFO=CS435\CN0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 753: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e. 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 754: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

SironaDental SystemsSidexis platform

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Requirements: Sirona Sidexis platform v5.5 Requirements: MIM200 v6.1, 1120 v2.40/032 Note: other 1120 matrixes 14x14=4096x4108, 11x14=4096x3232, 8x10=2304x2900 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 1120, Address=accordingly, Port=5040, Called AE=K1120 n MatrixX=4096, MatrixY=5132, ResPrinter=317.5, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=NORMAL, MAXDENS=300 n CONFIGINFO=CS435\CN0 MIM200 Setup: n on Configure, Network:

n Computer Name=e.g., Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On

Page 755: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape=3 i.e. 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 756: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

SironaDental SystemsSidexis platform

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

Requirements: Sirona Sidexis platform v5.5, MIM200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Note: other 8200 matrixes 14x14=4360x4244, 11x14=3272x4360 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8200, Address=accordingly, Port=5040, Called AE=K8200 n MatrixX=4360, MatrixY=5220, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On

Page 757: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space=On, Variable Border=On, PLUT Service=On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smoothing=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 758: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

SironaDental SystemsSidexis platform

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Sirona Sidexis platform v5.5, MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8500, Address=accordingly, Port=5040, Called AE=K8500 n MatrixX=3380, MatrixY=4280, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=11INX14IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set:

n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None

Page 759: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=11INx14IN (Always=N), Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 760: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

SironaDental SystemsSidexis platform

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M8700 DryView

Fiber Cable

Fiber Cable

Requirements: Sirona Sidexis platform v5.5, MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into MIM200 Destination Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8700, Address=accordingly, Port=5040, Called AE=K8700 n MatrixX=4096, MatrixY=5220, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None

Page 761: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 762: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

SironaDental SystemsSidexis platform

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Requirements: Sirona Sidexis platform v5.5, MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8100, Address=accordingly, Port=5040, Called AE=K8100 n MatrixX=4096, MatrixY=5216, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On

Page 763: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsb.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (i.e., external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 764: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

SironaDental SystemsSidexis platform

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Requirements: Sirona Sidexis platform v5.5 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Note: 8300 Portrait matrix 8x10=2256x2676 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8300, Address=accordingly, Port=5040, Called AE=K8300 n MatrixX=2736, MatrixY=2136, ResPrinter=300, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=LANDSCAPE, SIZEID=8INX10IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,10 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60

Page 765: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.811 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 i.e., Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 766: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: Sirona Sidexis platform v5.5 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8610, Address=accordingly, Port=5040, Called AE=K8610 n MatrixX=6200, MatrixY=5024, ResPrinter=655, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=LANDSCAPE, SIZEID=8INX10IN n MAGNTYPE=CUBIC, SMOOTHING=4, MAXDENS=300 n CONFIGINFO=LUT=0,5 MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set:

n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Mem=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600),Header/Line,Transfer=2000,Acq=60

SironaDental SystemsSidexis platform

Kodak DryView 8610

Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 767: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=5 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table=Linear in Transmittance n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n Smoothing Type=4 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=sidex n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 768: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

Sidexis platform via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Digital Science 969 HQ LASER IMAGER

SironaDental SystemsSidexis platform

Kodak MIM 200

DICOM Network

Fiber Cable

Fiber Cable

3 M H Q L a s e r I m a g e r

Kodak M969 HQ

Requirements: Sirona Sidexis platform v5.5, MIM200 v6.1, 969 v5.2 Note: This setup is basically also valid for 25 PS computer Note: other HQ matrixes 11x14=3020x3960, 8x10=2076x2788 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 969, Address=accordingly, Port=5040, Called AE=K969 n MatrixX=4096, MatrixY=4992, ResPrinter=311.5, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 969, Set: n General: Log.Name=969 n General: Database Name=969, Model=969, Memory=32 n Media Info: Media=35x43cm, 4096x5002, 4912, Blue n Media Info: Media=11x14in, 3030x4096, 4006, Blue n Media Info: Media=8x10in, 2086x2929, 2839, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None

Page 769: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.3457 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT=Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N) n Border=Black (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Negotiate Color Print=Off 969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 770: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

Sidexis platform via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Sirona Sidexis platform v5.5 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: other 8900 matrixes 14x14=4488x4488, 11x14=3514x4488 Note: other 8900 matrixes 10x12=3184x3828, 8x10=2528x3184 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8900, Address=accordingly, Port=5040, Called AE=8900 n MatrixX=4488, MatrixY=5464, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=0, MAXDENS=300 n CONFIGINFO=LUT=0,9 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any

SironaDental SystemsSidexis platform

DICOM Network

Kodak DryView 8900

Page 771: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=0 (Always=Y), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 772: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

Sidexis platform via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Sirona Sidexis platform v5.5 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: other 8150 matrixes 14x14=4438x4414, 11x14=3440x4438 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 8150, Address=accordingly, Port=5040, Called AE=DV8150 n MatrixX=4438, MatrixY=5390, ResPrinter=325, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=PORTRAIT, SIZEID=14INX17IN n MAGNTYPE=CUBIC, SMOOTHING=0, MAXDENS=300 n CONFIGINFO=LUT=0,9 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

SironaDental SystemsSidexis platform

DICOM Network

Kodak DryView 8150

Page 773: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=0 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 774: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

Sidexis platform via DICOM with Kodak Color Medical Imager 1000

Requirements: Sirona Sidexis platform v5.5 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: CMI1000 matrixes A4=2508x3134 ie 203.2x253.9

8.5x11=2508x2954 ie 203.2x239.3 Sirona Setup: n into Sidexis application under Services/System Config/Service set: n Multiuser=On, Other communication partners=On n into Sidexis application under Services/System Config/Service/Partner/New set: n Name:PRNSRV, File MailBox: C:\MEDST\PrnSrv\Spool\Test.sdx n Patient Databank=On, Reworking of image sent=On, click OK, OK n into file C:MEDST\CONFIG\Prnsrv.cfg set: n PrinterName=Kodak 1000, Addr.=accordingly, Port=5040, Called AE=CMI1000 n MatrixX=3134, MatrixY=2508, ResPrinter=314, NUMCOPIES=1, n PRIORITY=HIGH, MEDIUM=BLUE FILM, DESTINATION=PROCESSOR n SESSION=Sidexis film, ORIENTATION=LANDSCAPE, SIZEID=8INX10IN n MAGNTYPE=CUBIC, SMOOTHING=2, MAXDENS=300 n CONFIGINFO=LUT=0,9 CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP:

SironaDental SystemsSidexis platform

DICOM Network

Kodak CMI 1000

Page 775: Other OEM Setup Manuals

Sirona workstation Sidexis with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

n under Image Quality, Grayscale Image Quality: n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 776: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for SwissRay workstation SwissVision with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER................................ ................................ ................................ ... 2 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (1)................................ ......... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (1)................................ ......... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER (1)................................ ................................ .............................. 8 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER (1)................................ ................................ .............................. 10 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (1) ................................ ................................ ................................ ................................ ...... 12

n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 / Kodak Digital Science 969 HQ LASER IMAGER (1) ................................ ................................ ........... 14

n Kodak Digital Science 190 MEDICAL LASER PRINTER................................ ................................ ... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER (2,3,4) ................................ ................................ ........................... 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER (2,3,4) ................................ ................................ ........................ 21 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER (2,3,4) ................................ ................................ ........................ 24 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (3,4,5)................................ ................................ .......................... 27 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual) (4,5) ................................ ....... 30 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual) (4,5) ................................ ....... 33 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (4,5)................................ ................................ ............................ 36 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (4,5)................................ ................................ ............................ 39 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600) (4,5) ................................ ................................ ................................ ................................ .... 42

n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak Digital Science 969 HQ LASER IMAGER (4,5) ................................ ................................ ......... 45

n Kodak DryView 8900 LASER IMAGER................................ ................................ ................................ ... 48 n Kodak DryView 8150 LASER IMAGER................................ ................................ ................................ ... 51 n Kodak Color Medical Imager 1000 ................................ ................................ ................................ ........... 54

1 Setup valid also for Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.3 and v1.5.1. 2 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v3.2.1. 3 Setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v4.0. 4 setup valid also for Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v5.0, v5.2, v6.0. 5 setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 777: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

SwissRay workstation via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Note: 8300 Landscape matrix 8x10=2136x2736 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8300, AE Title=8300, Hostname=eg 150.224.150.2, Port=104 - Resolution=8 bit, - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=8x10 Inches, DPI=300, - Max Printable Box Size: W=2256 x H=2676, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=8x10, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8300, AE Title=8300, Hostname=eg 150.224.150.2, Port=104 - Resolution=8 bit, Magnification=Cubic - true size printing not supported by 8300: Film Size=8x10 Inches - Printable Box Size: W=2256 x H=2676, DPI=300 - Composed Print: Print all as one image=Off (film composer always disabled) - Add Black Borders=Off

Swissray Workstation

Kodak DryView 8300

DICOM Network

Page 778: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

- Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1,2:1V (ie one above the other),2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=8x10, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - true size printing not supported by 8300: therefore

Print with Original Size= Off (true size printing always disabled) - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2: 2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=1, Sharp/Smooth=2 n on 8300 Service Menu into Configure User set:

n Modality Group=4

Page 779: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

SwissRay via DICOM with Kodak PACS LINK ACQUISITION SYSTEM 9410 Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8500, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=11x14 Inches, DPI=325, - Max Printable Box Size: W=3380 x H=4280, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=11x14, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8500, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024

Swissray Workstation

Kodak DryView 8500 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 780: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

- Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=11x14 Inches (ie Print with Original Size=On) - Printable Box Size: W=3380 x H=4280, DPI=325 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=11x14, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n Installed TFT / ULUT=Ver693c0.w87, TFT / ULUT Emulation=Yes

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=2, TFT / ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 781: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

SwissRay via DICOM with Kodak PACS LINK ACQUISITION SYSTEM 9410 Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into 9410 Local Printers SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8700, AE Title= 9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=325, - Max Printable Box Size: W=4096 x H=5220, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8700, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024

Swissray Workstation

Kodak DryView 8700 Plus

Kodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Page 782: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

- Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=5220, DPI=325 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n Installed TFT / ULUT=Ver693c0.w87, TFT / ULUT Emulation=Yes

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=2, TFT / ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 783: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

SwissRay workstation via DICOM with Kodak PACS LINK ACQUISITION SYSTEM 9410 Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 9410 v1.6, 8100 v2.4.1 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8100, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=325, - Max Printable Box Size: W=4096 x H=5216, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8100, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=5216, DPI=325 - Composed Print: Print all as one image=On (to enable film composer)

Swissray Workstation

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Page 784: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

- Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2: 2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=90, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n Installed TFT / ULUT=Ver693c0.w87, TFT / ULUT Emulation=Yes on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=1, TFT / ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT= Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 785: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

SwissRay workstation via DICOM with Kodak PACS LINK ACQUISITION SYSTEM 9410 Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Note: 8300 Landscape matrix 8x10=2136x2736 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8300, AE Title= 9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=8 bit, - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=8x10 Inches, DPI=300, - Max Printable Box Size: W=2256 x H=2676, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=8x10, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8300, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution= 8 bit, Magnification=Cubic - only for true size printing: Film Size=8x10 Inches (ie Print with Original Size=On) - Printable Box Size: W=2256 x H=2676, DPI=300

Swissray Workstation

Kodak DryView 8300

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 786: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

- Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=8x10, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=1, TFT/ULUT= wrkstn83a.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 787: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

SwissRay workstation via DICOM with Kodak PACS LINK ACQUISITION SYSTEM 9410 Software v1.6 /

Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography (see also 8600)

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 9410 v1.6, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 8600 camera SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8610, AE Title= 9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit, only 8 bit if 8600), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=8x10 Inches, DPI=655, - Max Printable Box Size: W=5024 x H=6200, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=8x10, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8610, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit, only 8 bit if 8600), Magnification=Cubic - only for true size printing: Film Size=8x10 Inches (ie Print with Original Size=On)

Swissray Workstation

Kodak DryView 8610

Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Page 788: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

- Printable Box Size: W=5024 x H=6200, DPI=655 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=8x10, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 9410 Setup:

n on SCP PRINTER Menu, Current Provider, SCP Parameters: n Printer=8610, SCP AETitle=9410, Port=1024, Max.Associations= 5 n on SCP PRINTER Menu, Registered User: n SCU AETitle= accordingly, SCU IPAddr= accordingly n SCP=8610, Copies=1, Contrast Table=6 n Max.Density=350, Border Density=0, Mag.Type=8, Smoothing=1 n Polarity=1, Orientation=1, Set Req.Image Size=Off, Priority=Low n Gamma Table=Linear in Density, Contrast Group=1, Kernel Group=1 n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

n on LOCAL PRINTER Menu: n Printer Name=8610, Model=8600/8610, Output Board=Copper n Baud Rate=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12 (8 if 8600), Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=1, Installed TFT/ULUT= don’t care n Max.Density=350, Contrast=5, Border Density=0

8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, VRTX32=1.08, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1 on 1=Portrait n Gamma = Xmittance, Image Size=Scale To Fit, Detector Size= don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 789: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

SwissRay via DICOM with Kodak PACS LINK ACQUISITION SYSTEM 9410 Software v1.6 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 9410 v1.6, 969 v5.2 Note: other HQ matrixes 11x14=3020x3960, 8x10=2076x2788 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=969, AE Title= 9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=311.5, - Max Printable Box Size: W=4096 x H=4992, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=969, AE Title=9410, Hostname=eg 150.224.150.2, Port=1024 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=4992, DPI=311.5 - Composed Print: Print all as one image=On (to enable film composer)

Swissray Workstation

Kodak 9410 PACS Link

DICOM Network

Fiber Cable

Fiber Cable

3 M H Q L a s e r I m a g e r

Kodak M969 HQ

Page 790: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

- Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=969, Model=969, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n Installed TFT / ULUT=Ver693c0.w87, TFT / ULUT Emulation=Yes

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=969, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=969, Copies=1, Contrast Table=2, TFT / ULUT=Wrkstn2a.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 791: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

SwissRay workstation via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 190 rel. 1.7.29 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=190, AE Title=190, Hostname=eg 150.224.150.2, Port=5040 - Resolution=8 bit, - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=317.5, - Max Printable Box Size: W=4096 x H=5120, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=190, AE Title=190, Hostname=eg 150.224.150.2, Port=5040 - Resolution= 8 bit, Magnification=Cubic - true size printing not supported by 190: Film Size=14x17 Inches - Printable Box Size: W=4096 x H=5120, DPI=317.5 - Composed Print: Print all as one image=Off (film composer always disabled) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size)

Swissray Workstation

DICOM Network

Kodak 190 camera

Page 792: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

- Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - true size printing not supported by 190: therefore Print with Original Size= Off (true size printing always disabled) - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=0.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

Page 793: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, KELI 160 v5.2 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=160, AE Title=160, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=325, - Max Printable Box Size: W=4360 x H=5348, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=160, AE Title=160, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4360 x H=5348, DPI=325 - Composed Print: Print all as one image=On (to enable film composer)

Swissray Workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 camera

Page 794: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

- Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N)

Page 795: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 796: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 2180 rel. 2.17H Note: other 2180 matrixes 14x14=4096x4132, 11x14=3236x4132, 8x10=2286x2836 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=2180, AE Title=2180, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=321.5, - Max Printable Box Size: W=4096 x H=5156, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=2180, AE Title=2180, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=5156, DPI=321.5

Swissray Workstation

DICOM Network

Fiber Cable

Kodak 2180 camera

Kodak MIM 200

Page 797: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

- Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On

Page 798: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Modality=OT (Always=N) n Border=3.99 (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 799: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Note: other 1120 matrixes 14x14=4096x4108, 11x14=4096x3232, 8x10=2304x2900 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=1120, AE Title=1120, Hostname=eg 150.224.150.2, Port=5040 - Resolution=8 bit, - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=317.5, - Max Printable Box Size: W=4096 x H=5132, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=1120, AE Title=1120, Hostname=eg 150.224.150.2, Port=5040 - Resolution= 8 bit, Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=5132, DPI=317.5

Swissray Workstation

DICOM Network

Fiber Cable

Kodak 1120 camera

Kodak MIM 200

Page 800: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

- Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 0 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On

Page 801: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 802: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 8200 v3.5 Note: other 8200 matrixes 14x14=4360x4244, 11x14=3272x4360 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8200, AE Title=8200, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=325, - Max Printable Box Size: W=4360 x H=5220, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8200, AE Title=8200, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4360 x H=5220, DPI=325

Swissray Workstation

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 8200 camera

Page 803: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

- Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y)

Page 804: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n TFT/ULUT= Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off 8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 805: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

SwissRay via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8500, AE Title=8500, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=11x14 Inches, DPI=325, - Max Printable Box Size: W=3380 x H=4280, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=11x14, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8500, AE Title=8500, Hostname=eg 150.224.150.2, Port=5040

Swissray Workstation

Kodak DryView 8500 Plus

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Kodak MIM 200

Page 806: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

- Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=11x14 Inches (ie Print with Original Size=On) - Printable Box Size: W=3380 x H=4280, DPI=325 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=11x14, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y)

Page 807: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N), n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off 8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 808: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

SwissRay via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual)

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual camera

by basically using the correspondent Model into MIM200 Destination SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8700, AE Title=8700, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=325, - Max Printable Box Size: W=4096 x H=5220, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8700, AE Title=8700, Hostname=eg 150.224.150.2, Port=5040

Swissray Workstation

Kodak DryView 8700 Plus

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Kodak MIM 200

Page 809: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 34

- Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=5220, DPI=325 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y)

Page 810: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 35

n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off 8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 811: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 36

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 8100 v2.4.1 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8100, AE Title= 8100, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=325, - Max Printable Box Size: W=4096 x H=5216, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8100, AE Title=8100, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=5216, DPI=325 - Composed Print: Print all as one image=On (to enable film composer)

Swissray Workstation

Kodak DryView 8100

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Kodak MIM 200

Page 812: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 37

- Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Wrkstn2a.w87 (Always=Y), Contrast (dry)=1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N)

Page 813: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 38

n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT= Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 814: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 39

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: 8300 Landscape matrix 8x10=2136x2736 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8300, AE Title=8300, Hostname=eg 150.224.150.2, Port=5040 - Resolution=8 bit, - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=8x10 Inches, DPI=300, - Max Printable Box Size: W=2256 x H=2676, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=8x10, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8300, AE Title=8300, Hostname=eg 150.224.150.2, Port=5040 - Resolution= 8 bit, Magnification=Cubic - only for true size printing: Film Size=8x10 Inches (ie Print with Original Size=On) - Printable Box Size: W=2256 x H=2676, DPI=300 - Composed Print: Print all as one image=On (to enable film composer)

Swissray Workstation

Kodak DryView 8300

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 815: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 40

- Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=8x10, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5 n on Configure, SCP Services, select the specific modality, Modify:

n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= wrkstn83a.w8u (Always=Y), Contrast (dry)=1 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N)

Page 816: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 41

n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 817: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 42

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 / Kodak DryView 8610 LASER IMAGING SYSTEM / for Mammography

(see also 8600)

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 8610 v2.4 (if 8600 v2.5) Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8600 camera SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8610, AE Title=8610, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit, only 8 bit if 8600), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=8x10 Inches, DPI=655, - Max Printable Box Size: W=5024 x H=6200, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=8x10, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8610, AE Title=8610, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit, only 8 bit if 8600), Magnification=Cubic

Swissray Workstation

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Kodak MIM 200

Page 818: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 43

- only for true size printing: Film Size=8x10 Inches (ie Print with Original Size=On) - Printable Box Size: W=5024 x H=6200, DPI=655 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=8x10, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 8610 (or 8600), Set:

n General: Log.Name=8610 (or 8600) n General: Database=8610 (or 8600), Model=8610 (or 8600), Mem=32 n Media Info: Media=8x10in, 5025x6200, 6020, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12 (8 if 8600),Header/Line,Transfer=2000,Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=25.8065 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.5 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=16, Min Dmax 952=2

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= upmsv3kp.w8u (Always=N), Contrast (dry)=6 (Always=N) n Modality Group=1, Conv.Group=1, Gamma Table= Linear in Density

Page 819: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 44

n Image Dmin=0.00 (Always=N), Image Dmax=3.50 (Always=N) n Smoothing Type=1 (Always=N), Image Polarity=Normal (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Minify/Scale=On, Crop=Off, Source ID=swray n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off 8610 Setup: on 8610 Operator Menu into Test Menu, Software Version, verify:

n Imager=2.4, VRTX32=1.08, Contrast=6.P.2, Conv.Kernel=M.1.0 n (if 8600: Imager=2.5, Contrast=6.G.7, Conv.Kernel=1.0.5)

n on 8610 Operator Menu into Configure User set: n Density=16, Contrast=6, Sharp/Smooth=1, Film Layout: 1:1P n Gamma=Xmittance, Image Size=Scale To Fit, Detector Size=don’t care

n on 8610 Service Menu into Configure User set: n Ratio=1.00, Serial Control Intf.=1200,8,1,Even,Comma,3M, Memory=127 n Digital Interface: Parity=Even, Modality Group=1, Smoothing Group=1

Page 820: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 45

SwissRay workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Digital Science 969 HQ LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: MIM200 v6.1, 969 v5.2 Note: other HQ matrixes 11x14=3020x3960, 8x10=2076x2788 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=969, AE Title=969, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=311.5, - Max Printable Box Size: W=4096 x H=4992, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=969, AE Title=969, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4096 x H=4992, DPI=311.5 - Composed Print: Print all as one image=On (to enable film composer)

Swissray Workstation

DICOM Network

Fiber Cable

Fiber Cable

Kodak MIM 200

3 M H Q L a s e r I m a g e r

Kodak M969 HQ

Page 821: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 46

- Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off MIM200 Setup: n on Configure, Network: n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9 n on Configure, Destination, Add, Print, Direct, Qualified, 969, Set: n General: Log.Name=969 n General: Database Name=969, Model=969, Memory=32 n Media Info: Media=35x43cm, 4096x5002, 4912, Blue n Media Info: Media= 11x14in, 3030x4096, 4006, Blue n Media Info: Media= 8x10in, 2086x2929, 2839, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix on Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img per Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=6 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.3457 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0.26, Max H/V Mag=64, Min Dmax 952=1.7 n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Wrkstn2a.w87 (Always=Y), Contrast (dry)=2 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On

Page 822: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 47

n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off 969 Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 823: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 48

SwissRay workstation via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Note: other 8900 matrixes 14x14=9100x9084, 11x14=7136x9100 Note: other 8900 matrixes 10x12=6490x7764, 8x10=5164x6490 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8900, AE Title=8900, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=650, - Max Printable Box Size: W=9100 x H=11036, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8900, AE Title=8900, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=9100 x H=11036, DPI=650 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off

Swissray Workstation

DICOM Network

Kodak DryView 8900

Page 824: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 49

- Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr, Subnet Mask, Gateway Addr=accordingly n on Configuration, DICOM SCP, Communications:

n Port=5040, Association Limit=12, Source Name=DICOM n on Configuration, Destination:

n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT= Wrkstn2a.w87 (Always=N), Contrast=2 (Always=N) n Smoothing Type=2 (Always=N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N) n Text Box Location=None, Source ID=ws

Page 825: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 50

SwissRay workstation via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Note: other 8150 matrixes 14x14=4438x4414, 11x14=3440x4438 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=8150, AE Title=DV8150, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=14x17 Inches, DPI=325, - Max Printable Box Size: W=4438 x H=5390, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=14x17, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=8150, AE Title=DV8150, Hostname=eg 150.224.150.2, Port=5040 - Resolution=16 bit (or 8 bit), Magnification=Cubic - only for true size printing: Film Size=14x17 Inches (ie Print with Original Size=On) - Printable Box Size: W=4438 x H=5390, DPI=325 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled):

Swissray Workstation

DICOM Network

Kodak DryView 8150

Page 826: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 51

- Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=14x17, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Wrkstn2a.w87 (Always=Y) n Contrast=1 (Always=N), Smoothing Type=2 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 827: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 52

SwissRay workstation via DICOM with Kodak Color Medical Imager 1000

Requirements: SwissRay SwissVision v7.1 or v8.0 or v9.1 or v9.2 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Note: CMI1000 matrixes A4=2508x3134 and 8.5inx11in=2508x2954 SwissRay v7.1 Setup: - Note: the SwissRay print job is always in foreground (no background printing) - into DICOM/Print set: Local Settings: AETitle=SVISION_PR, Timeout=30 secs, - Printer: Add: - Name=1000, AE Title=CMI1000, Hostname=eg 150.224.150.2, Port=5040 - Resolution=8 bit, - to enable film composer-> Image Print Sequence: Print all as one Image=Yes - only for true size printing: Film Size=8x10 Inches, DPI=314, - Max Printable Box Size: W=2508 x H=3134, - Supported Formats (only if composer is not enabled) =Portrait: - 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Priority=Low, Film Size=8x10, Orientation=Portrait, - Print with Current C and B (ie Linear-in-Density LUT into Camera)=Yes, - Monitor Print Job=No, - only for true size printing: Print with Original Size=Yes - Layout (to be set for each film to be printed, only if no composer):1:1, 2:1V, 2:2 SwissRay v8.0 or v9.1 or v9.2 Setup: - into DICOM/Print set: - Printer: - Local Settings: AETitle=SVISION_PR, Timeout=30 secs - Add / Properties: - Name=1000, AE Title=CMI1000, Hostname=eg 150.224.150.2, Port=5040 - Resolution= 8 bit, Magnification=Cubic - only for true size printing: Film Size=8x10 Inches (ie Print with Original Size=On) - Printable Box Size: W=2508 x H=3134, DPI=314 - Composed Print: Print all as one image=On (to enable film composer) - Add Black Borders=Off - Supported Formats (only if composer is not enabled): - Portrait 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size)

Swissray Workstation

DICOM Network

Kodak CMI 1000

Page 828: Other OEM Setup Manuals

SwissRay workstation SwissVision with LASER IMAGER Products

Author: [email protected], Edition: May ´05 53

- Landscape 1:1, 2:1V (ie one above the other), 2:2 (only if all images have same size) - Options: - Copies=1, Medium=Blue Film, Priority=Low, Film Size=8x10, Orient.=Portrait, - Print with Current B and C (ie Linear-in-Density LUT into Camera)=On - only for true size printing: Print with Original Size= On - Monitor Print Job=Off (better to not enable Camera Status reporting) - Print in Background=On (to create a background printing queue) - Layout: - (to choose film format for each film to be printed, only if composer=Off):1:1, 2:1V, 2:2 - Note: into Option/DICOM/Storage set Presentation State SOP enabled=Off CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=7 (Always=Y) n TFT Set (From list)=Wrkstn2a.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=2 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 829: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for TheraView workstation with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER (not possible yet) ............................................ 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER......................................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER......................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (1).................................................................... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)(1)................ 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(1) .. 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 22 n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 830: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

TheraView workstation via DICOM with Kodak DryView 8300 LASER IMAGER

Note: connection with 8300 standalone not possible yet

Requirements: TheraView v3.12 Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=104, Calling AE Title=THERAVIEW, - Called AE Title=8300, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=2 n on 8300 Service Menu into Configure User set:

n Modality Group=0

Kodak DryView 8300

DICOM Network

TheraView workstation

Page 831: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

TheraView workstation via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: TheraView v3.12 Requirements: 190 rel. 1.7.29 TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname=Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=190, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

DICOM Network

Kodak 190 cameraTheraView workstation

Page 832: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

TheraView workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: TheraView v3.12 Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=1024, Calling AE Title=THERAVIEW, - Called AE Title=9410, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

TheraView workstation

Page 833: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 834: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

TheraView workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: TheraView v3.12 Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=1024, Calling AE Title=THERAVIEW, - Called AE Title=9410, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

TheraView workstation

Page 835: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 836: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

TheraView workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: TheraView v3.12 Requirements: 9410 v1.6, 8100 v2.4.1 TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=1024, Calling AE Title=THERAVIEW, - Called AE Title=9410, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu:

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

TheraView workstation

Page 837: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 838: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

TheraView workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: TheraView v3.12 Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=1024, Calling AE Title=THERAVIEW, - Called AE Title=9410, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup:

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

TheraView workstation

Page 839: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 840: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: TheraView v3.12 Requirements: MIM200 v6.1, KELI 160 v7.2 TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=160, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 cameraTheraView workstation

Page 841: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 842: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: TheraView v3.12 Requirements: MIM200 v6.1, 2180 rel. 2.17H TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=2180, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue) n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 cameraTheraView workstation

Page 843: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Modality=OT (Always=N) n Border=3.99 (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 844: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: TheraView v3.12 Requirements: MIM200 v6.1, 1120 rel. 2.40/032 TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=1120, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue) n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 cameraTheraView workstation

Page 845: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 846: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: TheraView v3.12 Requirements: MIM 200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=8200, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear) n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

TheraView workstation

Page 847: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 848: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: TheraView v3.12 Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=8500, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set: n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

TheraView workstation

Page 849: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N), n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 850: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: TheraView v3.12 Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=8700, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set: n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

TheraView workstation

Page 851: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 852: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: TheraView v3.12 Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=8100, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

TheraView workstation

Page 853: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 854: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

TheraView workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: TheraView v3.12 Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=8300, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

TheraView workstation

Page 855: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 856: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

TheraView workstation via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: TheraView v3.12 Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=8900, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4

DICOM Network

Kodak DryView 8900

TheraView workstation

Page 857: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=N), Warnings=No n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 858: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

TheraView workstation via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: TheraView v3.12 Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=DV8150, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

DICOM Network

Kodak DryView 8150

TheraView workstation

Page 859: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=11 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 860: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

TheraView workstation via DICOM with Kodak Color Medical Imager 1000

Requirements: TheraView v3.12 Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) TheraView Setup: - click on DICOM Network Transfer menu and set: - Hostname= Kodak, IP number=accordingly, Remote Port (SEND)=accordingly - Local Port (RECV)=5040, Calling AE Title=THERAVIEW, - Called AE Title=CMI1000, click on File and Save - click on Printer icon and under Printer Settings select: - Printer Name= Kodak, Type=DICOMPRINT CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP: n under Image Quality, Grayscale Image Quality:

n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=11 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N)

DICOM Network

TheraView workstation

Kodak CMI 1000

Page 861: Other OEM Setup Manuals

TheraView workstation with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No n under Modality Defaults:

n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No

n Save Changes and Exit

Page 862: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 1

Setup for Trophy workstation Windows equipped with DICOM Print module with LASER IMAGERS Connection via DICOM: n Kodak DryView 8300 LASER IMAGER......................................................................... 2 n Kodak Digital Science 190 MEDICAL LASER PRINTER......................................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual).................... 3 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)...... 4 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER......................................................................... 6 n Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER......................................................................... 8 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER .......................................................................... 10 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER ....................................................................... 12 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER ....................................................................... 14 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER (1).................................................................... 16 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)(1)................ 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)(1) .. 18 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER (1).................................................................... 20 n Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER (1).................................................................... 22 n Kodak DryView 8900 LASER IMAGER......................................................................... 24 n Kodak DryView 8150 LASER IMAGER......................................................................... 26 n Kodak Color Medical Imager 1000 ................................................................................. 28

1 Setup valid also for Kodak PACS LINK 25 PRINT SERVER.

Page 863: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 2

Trophy workstation via DICOM with Kodak DryView 8300 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 8300 v4.9.1, 8300 DICOM board v3.3, 8300 LUT v3.0.3B Trophy Setup: - under Office/Working place/Configuration Panel /DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8300, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=8300, - into Settings: IP Address=accordingly, Port=104 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=Off, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8300 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=8INX10IN - Magnif=Cubic, Smoothing=2, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job 8300 Setup: n on 8300 Operator Menu into Configure User set:

n Density=16, Contrast=10, Sharp/Smooth=2 n on 8300 Service Menu into Configure User set:

n Modality Group=0

Kodak DryView 8300

DICOM Network

Trophy

Dental Systems

Windows DICOM platform

Page 864: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 3

Trophy workstation via DICOM with Kodak Digital Science 190 MEDICAL LASER PRINTER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 190 rel. 1.7.29 Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=190, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=190, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 190 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=14INX17IN - Magnif=Cubic, Smoothing=NORMAL, Trim=Off, Border=Black, Empty=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=4:1, - also into Text select Add Patient Info=On and press OK to print the job 190 Setup: n On 190 Control Panel press Menu, Setup: n Printer Density=3.00, Curve Shape=3.0, Contrast=0, Contrast Pivot Density=1.2 n IPAddress=accordingly, Subnet Mask=accordingly, Gateway Address=accordingly n Port=5040, Network Node Name=Kodak MLP190, Connection Type=RJ45

DICOM Network

Kodak 190 cameraTrophy

Dental Systems

Windows DICOM platform

Page 865: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 4

Trophy workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 9410 v1.6, 8500 v1.34 Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into 9410 Local Printers Trophy Setup: - under Office/Working place/Configuration Panel /DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8500, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=9410, - into Settings: IP Address=accordingly, Port=1024 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8500 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=11INX14IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=2:1, - also into Text select Add Patient Info=On and press OK to print the job 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8500, Model=8500, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Kodak DryView 8500 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Trophy

Dental Systems

Windows DICOM platform

Page 866: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 5

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8500, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8500, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 867: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 6

Trophy workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 9410 v1.6, 8700 v1.34 Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into 9410 Local Printers Trophy Setup: - under Office/Working place/Configuration Panel /DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8700, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=9410, - into Settings: IP Address=accordingly, Port=1024 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8700 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=14INX17IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=4:1, - also into Text select Add Patient Info=On and press OK to print the job 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8700, Model=8700, Output=Fiber n Command Set=Superset, Baud=19200, Data=8, Stop=1, Parity=None n Pixel=12, Header/Line, Timeout=60, Transfer Rate=2 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87

Kodak DryView 8700 PlusKodak 9410 PACS Link

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Trophy

Dental Systems

Windows DICOM platform

Page 868: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 7

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8700, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly n SCP=8700, Copies=1, Contrast Table=9, TFT/ULUT=Pmsv3k.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 869: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 8

Trophy workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8100 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 9410 v1.6, 8100 v2.4.1 Trophy Setup: - under Office/Working place/Configuration Panel /DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8100, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=9410, - into Settings: IP Address=accordingly, Port=1024 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8100 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=14INX17IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=4:1, - also into Text select Add Patient Info=On and press OK to print the job 9410 Setup: on Device Setup, LOCAL PRINTERS: n Printer=8100, Model=8100 4096 pxls/line, Output=Copper n Baud=1200, Parity=Even, Data=8, Stop=1, Command Set=952 n Pixel=12, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=2, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=Ver693c0.w87 on Device Setup, SCP PRINTERS, Current Providers: n Printer=8100, AE Title= 9410, Port= 1024, Max Associations= 5 on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly

Kodak DryView 8100Kodak 9410 PACS Link

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Trophy

Dental Systems

Windows DICOM platform

Page 870: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 9

n SCP=8100, Copies=1, Contrast Table=9, TFT/ULUT=Pmsb.w87 n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=11 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0 8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 871: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 10

Trophy workstation via DICOM with Kodak PACS LINK 9410 ACQUISITION SYSTEM Software v1.6 /

Kodak DryView 8300 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 9410 v1.6, 8300 v4.9.1, 8300 LUT v3.0.3B Trophy Setup: - under Office/Working place/Configuration Panel /DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8300, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=9410, - into Settings: IP Address=accordingly, Port=1024 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=Off, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8300 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=8INX10IN - Magnif=Cubic, Smoothing=2, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job 9410 Setup: n on Device Setup, LOCAL PRINTERS:

n Printer=8300, Model=8300 Copper, Output=Copper n Command Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Pixel=8, Header/Line, Timeout=60, Transfer Rate=1 MHz n Film Mismatch=Print Always, Interpolation Type=831 n Interp Num=0, Max.Density=300, Contrast=6, Border Density=0 n TFT/ULUT Emulation=On, Installed TFT/ULUT=upmsv3k.w8u

n on Device Setup, SCP PRINTERS, Current Providers: n Printer=8300, AE Title= 9410, Port= 1024, Max Associations= 5

n on Device Setup, SCP PRINTERS, Registered Users: n SCU AETitle= accordingly, SCU IPAddr=accordingly

Kodak DryView 8300Kodak 9410 PACS Link

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Trophy

Dental Systems

Windows DICOM platform

Page 872: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 11

n SCP=8300, Copies=1, Contrast Table=10, TFT/ULUT=u1_109b.w8u n Max.Density=300, Border Density=0, Mag.Type=8, Smoothing=2 n Polarity=1, Orientation=1, Set Req.Image Size=No, Priority=Low n Interceptor=Yes, N-Event-Print Job=No, N-Event Printer=No n Trim=No, Attribute Warning=No n Contrast Test Mode=No, Contrast Test Mode Density=0

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 873: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 12

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 160 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM200 v6.1, KELI 160 v5.2 Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=160, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=160, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 160 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=14INX17IN - Magnif=Cubic, Smoothing=NORMAL, Trim=Off, Border=Black, Empty=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=4:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak160, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELI 160, Set: n General: Log.Name=KELI 160, IPAddr=100.100.100.30, n General: Database Name=KELI 160, Model=KELI 160 n Media Info: Media=35x43cm, 4361x5348, 5228, Any (Blue,Clear) n Supported Item: Collation=On, Text=On, Tonescaling on Image=On n Supported Item: Pivot Density=On, Rotation=On

Kodak MIM 200

DICOM Network

CrossedNetwork Cable

Kodak 160 cameraTrophy

Dental Systems

Windows DICOM platform

Page 874: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 13

n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=N), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation= Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

160 Setup: no modality-specific setup needed

Page 875: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 14

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 2180 LASER PRINTER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM200 v6.1, 2180 rel. 2.17H Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=2180, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=2180, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 2180 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=8INX10IN - Magnif=Cubic, Smoothing=NORMAL, Trim=Off, Border=Black, Empty=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak2180, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 2180, Set: n General: Log.Name=KELP2180, Database Name=KELP 2180 n General: Model=KELP 2180, Memory=24, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4136x5160, 5030, (Blue) n Media Info:Media=35x35cm,4136x4136,4006, (Blue) n Media Info: Media=11x14in, 3240x4136, 4006, (Blue)

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 2180 cameraTrophy

Dental Systems

Windows DICOM platform

Page 876: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 15

n Media Info: Media=8x10in, 2290x2840, 2710, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bil=On, Repl=On,Cubic=On, Cubic 2=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=2 n Formatting: Pixel Pitch=12.6582 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.2 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Modality=OT (Always=N) n Border=3.99 (Always=N), Film Base=Blue Film (Always=N) n Film Size=14INx17IN (Always=N), Film Output Dest=Bin 9 (Always=N) n Negotiate Color Print=Off

2180 Setup: n Optical Interface board will automatic configure into 2180, no setup needed

Page 877: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 16

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak Ektascan 1120 LASER PRINTER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM200 v6.1, 1120 rel. 2.40/032 Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=1120, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=1120, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 1120 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=8INX10IN - Magnif=Cubic, Smoothing=NORMAL, Trim=Off, Border=Black, Empty=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Computer Name=eg Kodak1120, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, KELP 1120, Set: n General: Log.Name=KELP1120, Database Name=KELP 1120 n General: Model=KELP 1120, Memory=20, Node ID=6 or accordingly n Media Info: Media=35x43cm, 4096x5132, 5034, (Blue) n Media Info: Media=35x35cm, 4096x4108, 4010, (Blue) n Media Info: Media=11x14in, 4096x3232, 3134, (Blue)

Kodak MIM 200

DICOM Network

Fiber Cable

Kodak 1120 cameraTrophy

Dental Systems

Windows DICOM platform

Page 878: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 17

n Media Info: Media=8x10in, 2304x2900, 2802, (Blue) n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=3, Min Vert Sep=0 n Formatting: Trim Width Enabled=0, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.5 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=2.8 n M952 Usage: Min H/V Mag=0, Max H/V Mag=0, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=Curve Shape (Always=Y) n Curve Shape= 3 ie 435 (Always=Y), Contrast (wet)=0 (Always=Y) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Interpolation=Cubic, Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

1120 Setup: n Optical Interface board will automatic configure into 1120, no setup needed

Page 879: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 18

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8200 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM 200 v6.1, 8200 v3.5 Note: This setup is basically also valid for 25 PS computer Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8200, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=8200, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8200 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=11INX14IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=2:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8200, Set: n General: Log.Name=8200, IPAddr=100.100.100.40, n General: Database Name=8200, Model=8200, Memory=32 n Media Info: Media=35x43cm, 4361x5223, 5133, Any (Blue,Clear)

Kodak MIM 200

DICOM Network

Crossed Network Cable

Kodak DryView 8200

Trophy

Dental Systems

Windows DICOM platform

Page 880: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 19

n Media Info: Media=35x35cm, 4361x4247, 4157, Any (Blue,Clear) n Media Info: Media=11x14in, 3272x4361, 4271, Any (Blue,Clear) n Supported Item: Collation=On, Common Text=On, Tonescaling=On n Supported Item: Remote Image Deletion=On, Rotation=On n Interpolation: No Magnification=On, Bilin=On, Repl=On n Interpolation: Cubic Spline=On, Cubic Convolution 2=On n Format Types: Custom=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n SCU: Density Space= On, Variable Border=On, PLUT Service= On n SCU: Curve Shape Tonescaling=On, Perception LUT Tonescaling=On n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8200 Setup on CONFIGURATION Menu: n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on DICOM Menu: SCU Config.: AE=MIM, TFT=VER693C0, C=6, Smooth=0 n on DICOM Menu: DICOM Config.: AE=NER_ANY, Port=1025

Page 881: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 20

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8500 LASER IMAGER / Plus (see also 8800/8500 Dual)

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM200 v6.1, 8500 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8500 Dual camera

by basically using the correspondent Model into MIM200 Destination Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8500, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=8500, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8500 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=11INX14IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=2:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8500, Set:

Kodak DryView 8500 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Trophy

Dental Systems

Windows DICOM platform

Page 882: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 21

n General: Log.Name=8500 n General: Database Name=8500, Model=8500, Memory=32 n Media Info: Media=11x14in, 3388x4283, 4193, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N), n Film Base=Blue Film (Always=N), Film Size=11INx14IN (Always=N) n Negotiate Color Print=Off

8500 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Disable Even, Timeout=60

Page 883: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 22

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8700 LASER IMAGER / Plus (see also 8800/8700 Dual and HQ)

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM200 v6.1, 8700 v1.34 Note: This setup is basically also valid for 25 PS computer Note: This setup is basically also valid for 8800/8700 Dual and HQ cameras

by basically using the correspondent Model into MIM200 Destination Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8700, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=8700, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8700 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=14INX17IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=4:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8700, Set:

Kodak DryView 8700 PlusKodak MIM 200

DICOM Network

3M 8700 DryView

Fiber Cable

Fiber Cable

Trophy

Dental Systems

Windows DICOM platform

Page 884: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 23

n General: Log.Name=8700 n General: Database Name=8700, Model=8700, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue n Output Params: Cmd=SuperSet,Baud=19200,Data=8,Stop=1,Parity=None n Output Params: Pixel=12, Header/Line, Transfer=2000 KHz, Acq=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsv3k.w87 (Always=Y), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8700 Plus Setup: n on COMM Menu: 969 Default n on IMAGE Menu: TFT=VER693C0, Dmax=3.00, Contrast=6, Density=14 n on EIB Menu: Pixel=12, Header/Line, Port=0, Parity=Enable Even, Timeout=60

Page 885: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 24

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8100 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM200 v6.1, 8100 v2.4.1 Note: This setup is basically also valid for 25 PS computer Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8100, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=8100, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8100 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=14INX17IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=4:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8100, Set: n General: Log.Name=8100 n General: Database Name=8100, Model=8100, Memory=32 n Media Info: Media=35x43cm, 4096x5223, 5133, Blue

Kodak DryView 8100Kodak MIM 200

DICOM Network

COPCIL BoardCopper Cable Control 9-pin

Data 37-pin

RS4229-pole Plug

Trophy

Dental Systems

Windows DICOM platform

Page 886: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 25

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=12, Header/Line, Transfer=1000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symmetric=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=12.8205 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3.1 n M952 Usage: Min H/V Mag=1, Max H/V Mag=64, Min Dmax 952=1.7

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= Pmsb.w87 (Always=N), Contrast (dry)=9 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=11 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Negotiate Color Print=Off

8100 Setup on CONFIGURATION Menu: n on SIB board (ie external switch below Control plugs): SW1=Down n on COMMUNICATIONS Menu: n Parity=Even, Stop=1, Data=8, 1200 baud, EOM=CR, Protocol=831/952 n Mem.Full=BSY, Alarm=Old, Acquire Timeout=90, P1,…,P6=0

n on IMAGE QLTY-> Mag Scaling=Off, Pixel Correct=Off, 952 Override=Off n on IMAGE QUALITY-> TFT FILES Menu: TFT=Ver693c0.w87 n on LOCAL PANEL Menu: Contrast=6, Density=3.00 n on SYSTEM Menu: Acquire=Digital, Max.Img.Columns=4361 n on DIGITAL Menu: Pixel Depth=12, Header/Line, Parity=Even

Page 887: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 26

Trophy workstation via DICOM with Kodak PACS LINK MEDICAL IMAGE MANAGER 200 Software v6.1 /

Kodak DryView 8300 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: MIM200 v6.1, 8300 v4.9.1, 8300 LUT v3.0.3B Note: This setup is basically also valid for 25 PS computer Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8300, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=8300, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=Off, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8300 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=8INX10IN - Magnif=Cubic, Smoothing=2, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job MIM200 Setup: n on Configure, Network:

n Node Name=MIM, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configure, Input, Network, Add: n Protocol=DICOM 3.0, Log.Name=DICOM, Type/Com=Keypad/COM9

n on Configure, Destination, Add, Print, Direct, Qualified, 8300, Set: n General: Log.Name=8300 n General: Database Name=8300, Model=8300, Memory=32 n Media Info: Media=8x10in, 2256x2676, 2596, Blue

Kodak DryView 8300Kodak MIM 200

DICOM Network

Control 9 pin

Data 37 pin

COPCIL board Copper Cable

Trophy

Dental Systems

Windows DICOM platform

Page 888: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 27

n Output Params: Cmd Set=952, Baud=1200, Data=8, Stop=1, Parity=Even n Output Params: Pixel=8, Header/Line, Transfer=2000 KHz, Acquire=60 n Supported Item: Collation=On, Text=On, Tonescaling=On, Rotation=On n Interpolation: NoMag=On, Bilin=On, Repl=On,Cubic Spline=On n Format Types: Custom=On, Slide=On, Row Symm.=On, SuperSlide=On n Format Types: 1, 2, 4, 6, 8, 9, 12, 15, 16, 20, 24, 30, 35=On n Formatting: Aspect Ratio Mix Page=On, Image Size Mix in Std Fmt=On n Formatting: DICOM Annotation Box=On, Req.Size Scale=On n Formatting: Req.Size Mix in Row=On, Trim=On n Formatting: Aspect Ratio Mix in Row=On, Image Size Mix in Row=On n Formatting: Req.Image Size=On, Req.Size Mix on Page=On n Formatting: True Landscape=On n Formatting: Max Img Band=20, Max Band per Page=20, Max Img Col=0 n Formatting: Max Img Row=0, Min Horiz Sep=2, Min Vert Sep=2 n Formatting: Trim Width Enabled=2, Trim Width Disabled=0 n Formatting: Pixel Pitch=11.9048 n Image Processing: Grayscale=On, Minify=On, Max Image Dmax=3 n M952 Usage: Min H/V Mag=1, Max H/V Mag=16, Min Dmax 952=1.5

n on Configure, SCP Services, select the specific modality, Modify: n PLUT=N, ToneScaling=PerceptionLUT (Always=Y) n TFT/ULUT= u1_109s.w8u (Always=Y), Contrast (dry)=10 (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=Off (Always=Y), Warning Status=On n Print Date=Off, Print Time=Off, Page Number=Off, Hosp.Name=Off n Modality ID=Off, Annotation Override=Off (Always=N) n Print Priority=Normal (Always=N), Image Polarity=Normal (Always=N) n Smoothing Type=2 (Always=N), Border=3.99 (Always=N) n Film Base=Blue Film (Always=N), Film Size=8INx10IN (Always=N) n Negotiate Color Print=Off

8300 Setup: n on Operator Menu set: D=16, C=6, Sharp/Smooth=0 ie Auto n on Operator Menu set: Film Layout: 1 on 1=Portrait n on Service Menu set: Ratio=1.00, Serial=1200,8,1,Even,Comma,3M, Memory=16 n on Service Menu set: Digital Interface: Parity=Even, Modality Group=1

Page 889: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 28

Trophy workstation via DICOM with Kodak DryView 8900 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 8900 rev.E ie v2.11 (ie DRE v2.11, MIM v5.6.b5, MCS v2.10) Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8900, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=8900, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8900 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=8INX10IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job 8900 Setup: n on Configuration, System, Network:

n Host Name=DV8900, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n General: Log.Name=8900 n Media Types: Media=35x43cm, 9100x11037, 10781, Any n Media Types: Media=35x35cm,9100x9087, 8831, Any n Media Types: Media=11x14in, 7137x9100, 8844, Any n Media Types: Media=10x12in, 6490x7767, 7511, Any n Media Types: Media=8x10in, 5167x6490, 6234, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On

DICOM Network

Kodak DryView 8900

Trophy

Dental Systems

Windows DICOM platform

Page 890: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 29

n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=25.5910, Min Horiz Sep=4 n Formatting: Min Vert Sep=4, Trim Width Enabled=4 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.30

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No n TFT=Pmsv3k.w87 (Always=N), Contrast=9 (Always=N) n Smoothing Type=11 (Always=N), Image Polarity (Always=N) n Image Dmin=0.00 (Always=N), Image Dmax=3.00 (Always=N) n NeventReports=No (Always=N), Warnings=No n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, Film Base=Blue Film (Always=N) n Film Size=8INx10IN (Always=N), Sorter Bin=Bin1 (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 891: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 30

Trophy workstation via DICOM with Kodak DryView 8150 LASER IMAGER

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: 8150 v0.08.b6 (DRE=DV8150_DRE_0.08.b6, MIM=MIM_v5.7.b6) Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=8150, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=DV8150, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=On, Accept 16 bits=On, Support Color=Off - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 8150 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=11INX14IN - Magnif=Cubic, Smoothing=11, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job 8150 Setup: n on Configuration, System, Network:

n Host Name=DV8150DRE, IPAddr=accordingly n Subnet Mask=accordingly, Gateway Addr=accordingly

n on Configuration, DICOM SCP, Communications: n Port=5040, Association Limit=12, Source Name=DICOM

n on Configuration, Destination: n AE Title: Log.Name=DV8150 n Media Types: Media=35x43cm, 4438x5390, 5262, Any n Media Types: Media=35x35cm, 4438x4414,4286, Any n Media Types: Media=11x14in, 3440x4438, 4310, Any n Formatting: Aspect Ratio Mix Page=On, Aspect Ratio Mix Row=On n Formatting: Image Size Mix in Std Fmt=On, Image Size Mix Row=On n Formatting: DICOM Annotation Box=On, Req.Image Size=On

DICOM Network

Kodak DryView 8150

Trophy

Dental Systems

Windows DICOM platform

Page 892: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 31

n Formatting: Req.Size Scale=On, Req.Size Mix Page=On n Formatting: Req.Size Mix Row=On, Trim=On, n Formatting: True Landscape=On, Rotation=On n Formatting: Minify/Crop=On, Tonescaling on Image Basis=On n Formatting: Max Img Band=7, Max Band Page=7, Max Img Cols=0 n Formatting: Max Img Rows=0, Pixel Pitch=12.8000, Min Horiz Sep=2 n Formatting: Min Vert Sep=2, Trim Width Enabled=2 n Formatting: Trim Width Disabled=0, Maximum DMAX=3.10

n on Configuration, DICOM SCP, SCP Services, select specific modality, Modify: n Negotiate Presentation LUT=No, Negotiate Color Print=No, n TFT Set Name=Pmsb.w87 (Always=Y) n Contrast=9 (Always=N), Smoothing Type=11 (Always=N) n Dmin=0.00 (Always=N), Dmax=3.00 (Always=N) n Image Polarity=Normal (Always=N) n NeventReports=No (Always=Y), Warnings=Yes n Print Priority=Normal (Always=N), Border=3.99 (Always=N) n 2mm Border=Yes, Film Clip Border=No, n Film Base=Blue Film (Always=N), Film Size=14INx17IN (Always=N) n Print Date=No, Print Time=No, Page Nbr=No, Hosp.Name=No, n Modality ID=No, Annotation Override=No, Density Patch=No n Image Resizing=Minify/Scale (Always=N), n Text Box Location=None, Source ID=ws

Page 893: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 32

Trophy workstation via DICOM with Kodak Color Medical Imager 1000

Requirements: Trophy v6.0.2 equipped with DICOM Print module Requirements: CMI-1000 v1.0.b8 (DRE=v1.0.b8, MIMCore=v2.0.b3) Trophy Setup: - under Office/Working place/Configuration Panel/DICOM Servers - on the top bar where all icons are, click on the icon Create and set: - into General: Name=1000, Description=don’t care, Status=On ie clicked - into Settings: Calling AE title=TROPHY, Called AE title=CMI1000, - into Settings: IP Address=accordingly, Port=5040 - into Services: Verification SOP Class=On, Print Management SOP Class=On - into Services: Support Greyscale=Off, Accept 16 bits=Off, Support Color=On - into Advanced: Verbose=Off, Debug=Off - to Print select an image and on top bar where all icons are, click on icon Print - select the Name of the printer eg 1000 and into Properties set: - Media Type=Blue Film, Destination=Processor, Film Size=8INX10IN - Magnif=Cubic, Smoothing=2, Trim=Off, Border=Black, Empty image=Black - also select Orientation=Portrait, Copies=1, Priority=MED, Layout=1:1, - also into Text select Add Patient Info=On and press OK to print the job CMI-1000 Setup: at Local Panel, under Media, set A4 or Letter ie what inside Paper Tray (CMI-1000 sw considers only this field and uses it as A4 or Letter (Always=Y): at Local Panel, under Menu, Imager Setup: n Network Setup:

n IPAddr=accordingly, Subnet Mask=accordingly, Gateway=accordingly n under More Settings: DICOM Port=5040

n Edit Host Name/AE Title=CMI1000 n Modality (SCU) Config (or after modality recognition): n Select Modality=accordingly, Modality Config.Assistant=Yes, Reset Config=No n Note: Color IQ settings used when images sent with Color DICOM SOP n under Image Quality, Color Image Quality: (no need to adjust, leave defaults)

n Match Monitor Colors=default ie sRGB Color Space Profile.icm n Adjust Color Tones=default ie Default_Contrast_100.icm

n Note: Grayscale IQ settings used when images sent with Grayscale DICOM SOP:

DICOM Network

Trophy

Dental Systems

Windows DICOM platform

Kodak CMI 1000

Page 894: Other OEM Setup Manuals

Trophy workstation Windows with LASER IMAGER Products

Author: [email protected], Edition: May ´05 33

n under Image Quality, Grayscale Image Quality: n Contrast=9 (Always=Y), TFT Set (From list)=Pmsv3k.w87 (Always=Y) n Wet Contrast=0 (Always=N), Curve Shape=429 (Always=N) n under More Quality Settings: n Tonescaling=Presentation LUT (Always=N), n Image Dmax=220 (Always=N), Image Dmin=10 (Always=N) n Smoothing=11 (Always=Y), Polarity=Positive (Always=N) n Interpolation=CUBIC (Always=N), Trim=No (Always=N) n Page Orientation=PORTRAIT (Always=N), Negotiate PLUT=No

n under Modality Defaults: n Media Size=8.5x11 (Always=N), don’t care, this field plays no role n Image Resizing=Minify (Always=N), n Priority=Normal (Always=N), NeventReports=No (Always=Y), n Warnings=Yes, Color=Yes n (set Color=No when only b/w images are printed and set it to be sure n to apply to the b/w images the Greyscale Image Quality settings) n Page Annotation: n Hosp.Name=No, Modality ID=No, Page Nbr=No, Date=No, Time= No