8
LEDLUM LTX TRI-PROOF 5.8GHz 5 66 Tri-Proof LTX Serie Microwave Motion Sensor Optional mit E . COM GmbH Direkt Montage Schwenkbare Montage Seilabhänger Montage D

Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

LEDLUM LTX TRI-PROOF

5.8GHz566

Tri-Proof LTX Serie

Microwave Motion SensorOptional mit

E.COM GmbH

Direkt Montage Schwenkbare Montage

Seilabhänger Montage

D

Page 2: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

Copyright C 2016 Spring

TF E.Com GmbH

Temperature Characteristics T-ambient 25 C

Temperature

Operating -20~+40℃Storage -40~+85℃

Electrical CharacteristicsInput Voltage: US AC100~277V 50/60Hz

EU AC200~240V 50/60Hz

PF≥0.93 THD<20%≥0.90

O

Before installing the lighting fixtures, please read this instruction manual carefully.

The lighting fixtures should be installed, connected and tested by a certified installer based on the local regulations.

Lamps should always be installed or replaced with care.

Please check the local voltage in accordance with the product requirements before using the product.

Relamping only can be done when the power is off and the lamp is completely cooled down.

When a lamp is to be cleaned, make the power off and let it cool down completely.Clean the fixture with a soft cloth and a standard PH neutral detergent. Stainless steel finishing should be maintained regularly.

Misuse of, or changes to the fixture shall nullify the guarantee.

Don’t cover the fixtures with flammable materials.

Exclusively replaced by the manufacturer or his service agent or the similar qualified person in order to avoid a hazard.

/01

Matters needing attention

1 Type Linear

2 Length code

3 Power code

4 Version

PS:

WW(3000K) NW(4000K) DW(5000K) CW(6500K)CCTRange:

Product Number Explanation

ledlum LTX1560/1R

www.ledlum.com

LEDLUM LTX Tri-Proof

Page 3: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

TF E.Com GmbH

/02Copyright C 2016 Spring

With sufficient ambient light,the sensor does not switch on the lamp.

With insufficient ambient light,the sensor switches on thelamp when motion is detected.

After hold time , the sensordims the lamp at a low lightlevel if no new motion trigger.

After stand-by period , the sensor switches off the lamp is no motionis detecred in its detection zone.

Steps dimming control demonstration

www.ledlum.com

LEDLUM LTX Tri-Proof

Optional mit LTX Microwaver Sensor Technical Data

Page 4: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

TF E.Com GmbH

/03Copyright C 2016 Spring

Special application for underground parking

Widely used

Parking lot

Offices

Factories

Passageway

subway station

Warehouse

Stadium

Detection radius up to 10m ,diameter up to 20m

For general parking,when the car close to the lamp will light up, such easy to cause the driver could not be instantly adapt to light shifting sharply and discomfort,however,LEDLUM provide aperfect solution for such a defect,it can make the driver the car at a distance of 10 meters off the lamps then light up automatically.

2.5m3m

4m

10m

10m

5m 6m8m

10m

www.ledlum.com

LEDLUM LTX Tri-Proof

Page 5: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

TF E.Com GmbH

SupermarketExhibition hallParking placeEtc

COMMERCIAL LIGHTING PUBLIC LIGHTING INDUSTRIAL LIGHTING

TunnelMTR stationTrain stationBus stationAirportEtc

Factory/WarehouseEtc

/04

Patent and functional design with imaginative appearance

High stability isolated driver

Excellent heat dissipation depending on whole aluminum housing

Maximum efficacy and minimum glare

High-tech optical design

No UV ,No lead, No mercury

LEDLUM LTX Tri-proof led fixture for IP66 water-proof,dustproof and corrosion-proof

Model NO.

ledlum LTX0620

Size C(mm)

84

84

84

84

84

Size A(mm)

600

900

1200

1500

1500

Size B(mm)

71

71

71

71

71

Size D(mm)

800

800

800

800

800

1. Features

2.Application

3.Product Dimension

With lux sensorOptional als LTX Emergency Tri-Proof

Sensor hidden in the lamp

Copyright C 2016 Spring

Drive with over current ,over voltage and over temperature protection

R

ledlum LTX0930R

ledlum LTX1240R

ledlum LTX1550R

ledlum LTX1560/1R

www.ledlum.com

LEDLUM LTX Tri-Proof

Page 6: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

TF E.Com GmbH

A : Make a right position and screw hole B : Screw the steel cable onto the ceiling

A.Suspending

Ceiling

Open hole

Electric drill Steel cable

Power ONPower OFF

Power OFF

PLS note : PLS put the terminal of

power cable into water proof box

and use a listed water proof bushing

when you link the power

C : Hung the fixture under the steel cable and secure the fixture by steel cable

D: Adjust the position of the fixture and clean it..

Model NO.

2835

2835

2835

2835

2835

Light Source

108

156

216

264

324

LED QTY (pcs)

20

30

40

50

65

Power (W)

6000K

6000K

6000K

6000K

6000K

CCT (K)

CRI

>80

>80

>80

>80

>80

Cover Lm/W

150

150

150

150

150

ClearLumens

3000

4500

6000

7500

9750

Cover Lm/W

140

140

140

140

140

Frosted Lumers

2800

4200

5600

7000

9100

BeamAngle

120o

120o

120o

120o

120o

/05

4. Parameter

5.Installation

WW(3000K) NW(4000K) DW(5000K) CW(6500K)CCTRange:

Copyright C 2016 Spring

ledlum LTX0620R

ledlum LTX0930R

ledlum LTX1240R

ledlum LTX1550R

ledlum LTX1560/1R

www.ledlum.com

LEDLUM LTX Tri-Proof

Page 7: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

TF E.Com GmbH

A: Make a right position and screw hole

C: Install the lamp into the clips. D: Adjust the position of the fixture and clean it..

B: Screw the clip on the ceiling tightly

Open hole

Electric drill

LED Tri-proof light

Metal clip

Screw driver

Open hole

Screw

Metal clip

B.Ceiling Mounted

Power OFF

Note : pls put the terminal of power cable into water proof box and use a listed water proof bushing when you link the power

Copyright C 2016 Spring

Power ON

Power OFF

/06

Pls note :

Metal Card

One package two pcs

Standard accessories Optional accessories

Above installation“ B” belongs to our standard installation, if you want to choose our way of “A” installation then you need to select our optional accessories and pay.

steel cable

One package two pcs

6.Wiring diagram

LED lampL

L

NPE

PE

NAC 100-277V/200-240V

www.ledlum.com

LEDLUM LTX Tri-Proof

Page 8: Optional mit Microwave Motion Sensor - LEDLUM · LED Tri-proof light LED Tri-proof light 1 2 3 Metal card buckle Metal card buckle Manual 1pc 2pcs Model NO. 2pcs 4 Steel cable 2pcs

TF E.Com GmbH

7.Packaging

LED Tri-proof light

LED Tri-proof light

1

2

3

Metal card buckle

Metal card buckle

Manual

1pc

2pcs

Model NO.

2pcs

4 Steel cable 2pcs5

Adjustable buckle

1pcs

A.Pack listQuantitySequence

Number

1 6 685x307x223

985x307x2231

Model No

6

B.Packing Data

6pcs/cart on

1.877 12.362

17.0742.579

1 6 1285x307x223

1585x307x2231

1

6

3.342 22.152

27.0864.096

1585x307x2236 27.0864.096

N .W. / pcs(kg)

SingleBox Pcs/CTN G .W. /CTN

(kg)Meas(mm)

9.AttentionThis specification is for reference only,we reserve the right to change without notice.If you need the updated info,please contact local distributors or visit our website at http://www.ledlum.com.

/07Copyright C 2016 Spring

Safety standards UL 8750; UL 1598; EN 60598-1: 2015; EN 60598-2-2: 2012;EN 62031: 2008+A1: 2013+A2: 2015; EN 62493: 2015; EN 62471: 2008;EMC emission Compliance to EN55015: 2013,EN61000-3-2: 2014; EN61000-3-3: 2013;EMC immunity Compliance to EN61547: 2009; Certification D EN 60598-2-24;

8.Safety & EMC

ledlum LTX0620R

ledlum LTX0930R

ledlum LTX1240R

ledlum LTX1550R

ledlum LTX1560/1R

www.ledlum.com

LEDLUM LTX Tri-Proof