TM 11-6665-245-12

TECHNICAL MANUAL

OPERATOR AND ORGANIZATIONAL

MAINTENANCE MANUAL

RADIAC SET

AN/PDR-56F

(NSN 6665-00-211-6895)

This copy is a reprint which includes current

pages from Changes 1 and 2.

HEADQUARTERS, DEPARTMENT OF THE ARMY

5 DECEMBER 1980

Page 2: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

The check source used in this equipment contains Thorium (a radioactive metal).Thorium is a hazardous material. Injury or disease may result if the Thorium checksource is not handled properly.Observe the following precautions:Do not scratch or abrade the check source in any way to produce small particles. Ifsmall particles are produced, use extreme caution to avoid inhalation—Do not allowparticles to enter the body, through open cut or mouth. Wash any area suspected ofbeing contaminated with Thorium with luke warm water and a non-abrasive soap.Contact qualified medical personnel and the local Radiological Protection Officer(RPO) immediately if you are exposed to check source material.Use extreme care not to touch, scratch, or break or remove the surface of the checksource while handling them.Should the check source become dislodged from the radiac set, return the radiac setand check source for maintenance.Never place a dislodged check source in your pocket.Do not clean check source with abrasives.Refer to TB 43-0116, TB 43-0122, and AR 385-11 for instructions on first aid, safehandling, storage and disposal of radioactive material.

Page 3: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

CHANGE

NO. 2

TM 11-6665-245-12C2

HEADQUARTERSDEPARTMENT OF THE ARMY

WASHINGTON, DC, 15 January 1986

OPERATOR’S AND ORGANIZATIONALMAINTENANCE MANUALRADIAC SET AN/PDR-56F(NSN 6665-01-113-9530)

TM 11-6665-245-12, 5 December 1980, is changed as follows:

1. Remove and insert pages as indicated below.

2. New or changed material is indicated by a vertical bar in the margin of the page,

3. Added or revised illustrations are indicated by a vertical bar adjacent to the figure caption.

Remove Pagesi and ii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 thru 1-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 thru 2-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-1 thru B-3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C-3 thru C-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Insert Pagesi and ii1-1 thru 1-42-1 thru 2-83-1/(3-2 blank)A-1/(A-2 blank)B-1 thru B-3/(B-4 blank)C-3 thru C-6

4. File this change sheet in front of the publication.

Page 4: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

By Order of the Secretary of the Army:

Official:

JOHN A. WICKHAM JR.General, United States Army

Chief of Staff

MILDRED E. HEDBERGBrigadier General, United States Army

The Adjutant General

DISTRIBUTION:To be distributed in accordance with DA Form 12-36 literature

requirements for AN/PDR-56F.

Page 5: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12C 1

CHANGE

No. 1

Operator and OrganizationalMaintenance Manual

RADIAC SET AN/PDR-56F(NSN 6665-01-113-9530)

HEADQUARTERSDEPARTMENT OF THE ARMY

WASHINGTON, DC, 28 January 1983

TM 11-6665-245-12, 5 December 1980, is changed as follows:1. The title of the manual is changed as shown above.2. New or changed material is indicated by a vertical bar in the margin of the page.3. Remove and insert pages as indicated below.

Remove Inserti and ii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i and ii1-1 and 1-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 and 1-22-1 and 2-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 and 2-23-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-14-1 and 4-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 and 4-2A-1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1C-3 through C-6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-3 through C-5/(C-6 blank)

4. File this change sheet in front of the publication for reference purposes.

By Order of the Secretary of the Army:

Official:

ROBERT M. JOYCEMajor General, United States Army

The Adjutant General

Distribution:

To redistributed in accordance with Special Mailing List.

E. C. MEYERGeneral, United States Army

Chief of Staff

Page 6: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

TECHNICAL MANUAL HEADQUARTERSDEPARTMENT OF THE ARMY

No. 11-6665-245-12 WASHINGTON, DC, 5 December 1980

OPERATOR’S AND ORGANIZATIONAL MAINTENANCE MANUALRADIAC SET AN/PDR-56F(NSN 6665-01-113-9530)

REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS

You can help improve this manual. If you find any mistakes or if you know of a wayto improve the procedures, please let us know. Mail your letter, DA Form 2028(Recommended Changes to Publications and Blank Forms) or DA Form 2028-2located in back of this manual direct to Commander, US Army Communications-Electronics Command and Fort Monmouth, ATTN: AMSEL-ME-MP, Fort Monmouth,NJ 07703-5007.

In either case, a reply will be furnished direct to you.

CHAPTERSection

CHAPTER

CHAPTER

1.I .

Il.

2.

3.

TABLE OF CONTENTS

INTRODUCTIONGeneralScope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Consolidated Index of Army Publications and Blank Forms . . . . . . . . . . . .Maintenance Forms, Records and Reports . . . . . . . . . . . . . . . . . . . . . . . . . .Administrative Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Reporting Equipment improvement Recommendations (EIR). . . . . . . . . . .Hand Receipt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Destruction of Army Materiel to Prevent Enemy Use . . . . . . . . . . . . . . . . . .Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Description and DataPurpose and Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Tabulated Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

OPERATING INSTRUCTIONSOperator Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Initial Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Monitoring Terrain, Supplies and Equipment . . . . . . . . . . . . . . . . . . . . . . . .Monitoring Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Equipment Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

OPERATOR MAINTENANCE INSTRUCTIONSScope of Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Tools, Materials and Equipment Required for Maintenance . . . . . . . . . . . .Routine Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operator Preventive Maintenance Checks and Services (PMCS) . . . . . . . .Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Paragraph

1-11-21-31-41-51-61-71-8

1-91-101-11

2-12-22-32-42-5

3-13-23-33-43-53-6

Change 2

Page

1-11-11-11-11-11-11-11-1

1-11-11-2

2-12-22-22-32-4

3-13-13-13-13-13-1

i

Page 7: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

TABLE OF CONTENTS - Continued

CHAPTERSection

APPENDIX

Section

APPENDIXSection

APPENDIXSection

Table

1-12-14-1

Figure

1-11-21-32-12-22-32-42-54-1B-1

4.I.

Il.

Ill.

IV.

A.B.I.Il.

C.I.Il.Ill.IV.

D.I.Il.

ORGANIZATIONAL MAINTENANCE INSTRUCTIONSTools and EquipmentTools and Equipment Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Materials Required for Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Repainting and Refinishing InstructionsPreparation for Painting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Touchup Painting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .TroubleshootingGeneral Troubleshooting Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Troubleshooting by Visual inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Maintenance of the Radiac SetMaintenance of the Radiacmeter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Preparation for Storage or Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Paragraph

4-14-2

4-34-44-5

4-64-7

4-84-9

REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . COMPONENTS OF END ITEM LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Integral Components of End Item . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE ALLOCATIONIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance Allocation Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Tool and Test Equipment Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Remarks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

EXPENDABLE SUPPLIES AND MATERIALS LISTIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Expendable Supplies and Materials List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LIST OF TABLES

Title

Tabulated Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operator’s Controls and lndicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Troubleshooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

LIST OF FIGURES

Title

Radiac Set, AN/PDR-56F Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Radiacmeter lM-160F/PDR-56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Case, Radiac Set CY-7375/PDR-56F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Operator’s Controls and lndicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Radiac Probe DT-224B/PDR-56 Positioned Over Check Source . . . . . . . . . . . . . . . . . . .AN/PDR-56F with X-Ray Probe, DT-590A/PDR-56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .X-Ray Probe DT-590A/PDR-56 Positioned Over Check Source . . . . . . . . . . . . . . . . . . . .Aux Probe installed on Main Probe Handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Battery Compartment Cover, Exploded View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Components of Radiac Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page

4-14-1

4-14-14-1

4-14-1

4-24-2

A-1B-1B-1B-3

C-1C-3C-5C-6

D-1D-3

Page

1-22-14-1

Page

1-31-41-52-42-52-62-72-84-3B-2

ii Change 2

Page 8: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

CHAPTER 1INTRODUCTION

Section I. GENERAL

1-1. ScopeThis manual contains instructions for operatorand organizational maintenance for Radiac SetAN/PDR-56F (radiac set). It includes instructionsfor installing, operating and maintaining theequipment. It also lists tools, materials and testequipment for operator and organizat ionalmaintenance.

1-2. Consolidated Index of Army Pub-Iications and Blank Forms

Refer to the latest issue of DA Pam 310-1 to deter-mine whether there are new editions, changes oradditional publications pertaining to the equip-ment.

1-3. Maintenance Forms, Records andReports

a. Reports of Maintenance and Unsatisfac-tory Equipment. Department of the Army formsand procedures used for equipment maintenancewill be those prescribed by DA Pam 738-750 as con-tained in Maintenance Management Update.

b. Report of Packaging and Handling Defi-ciencies. Fill out and forward SF 364 (Report ofDiscrepancy (ROD) ) as p resc r ibed in AR735-11-2/DLAR 4140.55/NAVMATlNST 4355.73A/AFR400-54/MCO 4430.F.

c. Discrepancy in Shipment Report. Fill outand forward Discrepancy in Shipment Report(DISREP) (SF361) as prescribed in AR55-38/NAVSUPINST 4610.33C/AFR 75-18/MCOP4610.19D/DLAR 4500.15.

equipment from administrative storage, the PMCSshould be performed to assure operationalreadiness. Disassembly and repacking of equip-ment for shipment or limited storage are coveredin paragraph 4-9.

1-5. Reporting Equipment ImprovementRecommendations (EIR)

If your Radiac Set AN/PDR-56F needs improve-ment, let us know. Send us an EIR. You, the user,are the only one who can tell us what you don’tlike about your equipment. Let us know why youdon’t like the design. Put it on an SF 368 (QualityDeficiency Report). Mail it to Commander, USArmy Communications-Electronics Commandand Fort Monmouth, ATTN: AMSEL-ME-MP, FortMonmouth, NJ 07703-5007. We’ll send you a reply.

1-6. Hand ReceiptThis manual has a companion document with aTM number followed by “HR” (which stands forHand Receipt). The TM 11-6665-245-12-HR con-sists of preprinted hand receipts (DA Form 2062)that list end item related equipment (i.e., COEI, Blland AAL) you must account for. As an aid to pro-perty accountability, additional HR manuals maybe requisitioned from the US Army AdjutantGeneral Publications Center, Baltimore, MD, inaccordance with the procedures in Chapter 3, AR310-2 and DA Pam 310-10.

1-7. Destruction of Army Materiel to Pre-vent Enemy Use

1-4. Administrative StorageAdministrative Storage of Equipment issued toand used by Army activities will have preventivemaintenance performed in accordance with thePMCS charts before storing. When removing the

Destruction of Army Electronics materiel to pre-vent enemy use shall be in accordance with TM750-244-2.

1-8. CalibrationCalibration procedure for Radiac Set, AN/PDR-56F is contained in TM 11-6665-245-34.

Section Il. DESCRIPTION AND DATA

1-9. Purpose and Use used to monitor terrain, personnel and equipmentThe Radiac Set AN/PDR-56F is a portable, battery for alpha and gamma radiation contamination.operated scintillation type instrument for fielduse in the detection and measurement of alpha 1-10. Descriptionradiation and low energy gamma radiation. It is The Radiac Set AN/PDR-56F is comprised of the

components shown in Figure 1-1. The com-ponents are described below:

Change 2 1-1

Page 9: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

a. Radiacmeter lM-160F/PDR-56 is composedof a two piece, cast metal box which has a carry-ing handle attached to the panel which forms thetop of the box. The panel is used to mount all theoperating controls, the instrument meter, cableconnectors, and a plate used to hold in two bat-teries. The rest of the box forms a cover for the in-ternal components which are attached to the in-side of the top panel. The bottom of the box(Figure 1-2) has a white plastic sheet glued to it.The plastic sheet contains a small piece ofthorium in its center. The thorium is used ascheck source for the radiacmeter.

b. Probe, Radiac DT-224B/PDR-56 (main pro-be) is a metal box with a handle extended above itso that i t can be f i t ted together with theradiacmeter (Figure 1-1). The handle of the mainprobe fits inside the handle of the radiacmeterand they are fastened together with a captivescrew in the radiacmeter handle. The bottomplate of the main probe (Figure 1-2) has six slotscut into it to form a window area. The window areais covered on the inside with a very thin plasticand foil sheet (light barrier) which makes the mainprobe light tight but allows for the entry of alpharadiation. When the main probe is not in use, aplastic window cover must be placed over the win-dow area to protect the light barrier. The mainprobe and the radiacmeter are connected elec-trically by a short coiled cable.

c. Probe, Radiac DT-228A/PDR-56 (aux probe)is a metal housing which is designed to fit ontothe main probe for use in detecting alpha con-tamination when the main probe would be toobulky. In this case, the main probe is reassembledon it. The aux probe also contains a window areaand a light barrier. The light barrier of the auxprobe contains a wire screen to protect it fromsharp objects. It must also be protected by theplastic aux probe cover when not in use. Theplastic cap in the end of the aux probe is a dustand dirt cover.

d. P r o b e , Radiac DT-590A/PDR-56F (x-rayprobe) is a metal cylindrical housing which is de-signed to be attached to the coil cord cable inplace of the main probe for use in detecting lowenergy gamma radiation (areas contaminated byPlutonium-239 material), In this case, the mainprobe is disconnected and removed from theradiacmeter and the probe handle is connected tothe x-ray probe. The retractile cable is then con-nected to the x-ray probe. The extension handlemay be connected to permit use of the probe inthe standing position or to monitor overhead

1-2 Change 2

areas. The x-ray probe contains a wire screen toprotect the scintillation crystal assembly fromsharp objects.

e. C a s e , Radiac Set CY-7375/PDR-56F(storage case) is made of sheet steel, has ahinged cover, a carrying handle, and two cover lat-ches. The inside of the storage case (Figure 1-3) isseparated into compartments for storage of thecomponents of the Radiac Set AN/PDR-56F. Rub-ber cushioning pads and a gasket (to make thestorage case watertight) are cemented to the in-side of the storage case.

f. Miscellaneous components such as theHeadset, Electrical H-43B/U (headset), HarnessST-123/PDR-18A (carrying strap), and the exten-sion handle are also provided. The extension han-dle is an assembly of two telescoping aluminumtubes. The length of the extension handle is ad-justed by loosening a clamping nut and slidingthe two tubes to the length desired and thenretightening the clamp nut.

1-11. Tabulated DataThe physical, functional, and performance data islisted in Table 1-1.

Table 1-1. Tabulated Data

Weight

Size

Temperature Limits:

Input Power Requirement:

Radiation Measured:

Detection Efficiency:

Accuracy:

Variable Meter Ranges:

Indications:

Detection Area:

Battery Life Expectancy:

25.75 pounds (11.68 kg)

5 in. x 15 in. x 11.375 in.12.7 cm x 38.1 cm x 28.89 cm

-20 degrees C to + 50 degrees C

3.0 vdc (two type BA “D” cells)

(Alpha) 3 MeV (and above, up to106 counts) (Gamma) 10 keV to60 keV - adjustable

Greater than 11%

±20% over upper 80% of 103

counts per minute (cpm) range

1 03, 104, 105, 106 c p m

Meter and Headphone

Main Probe - 17 cm2, AuxiliaryProbe - 11 cm2: X-Ray Probe - 10c m2

50 hours with continuous use

Page 10: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Figure 1-1. Radiac Set, AN/PDR-56F Components

Change 2 1-3

Page 11: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

Figure 1-2.

TM11-6665-245-12

1-4C

han

ge 2

Page 12: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

Figure 1-3. Case, Radiac Set CY-7375/PDR-56F

1 - 5

Page 13: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

CHAPTER 2OPERATING INSTRUCTIONS

2-1. Operator Controls (Figure 2-1)Refer to Table 2-1 for operator controls and indicators.

Table 2-1. Operator’s Controls and Indicators

CONTROL, INDICATOR, ORCONNECTOR

Indicating Meter

Selector Switch(6 position rotary switch)

Meter Reset (momentarypush button switch)

Light Switch (momentarypush button switch)

Headphone Connector

FUNCTION

Indicates battery condition or counts per minutes in four ranges depen-ding on selector switch position.

Turns radiacmeter on and off. Changes internal circuits and indicatingmeter to check batteries and measure alpha radiation as follows:

Sw. Pos.

OFF

BATT

1M

100K

10K

Meter Indication

Radiacmeter is off (all otheron).

Batteries are good if needlescale.

Alpha radiation is measured frper minute (CPM).

positions: equipment is

s in BATT area of meter

om .0 to 1 million counts

Same as position 1M except that measurement rangeis 0 to 100,000 counts per minute (CPM).

Same as position 1M except that measurement rangeis 0 to 10,000 counts per minute (CPM).

1K Same as position 1M except that measurement rangeis 0 to 1,000 counts per minute (CPM).

Reset indicating meter rapidly to zero.

Applies battery power to small lamp inside indicating meter to illuminateindicating meter face.

Used to connect CPM electrical signal to earphones.

Change 2 2-1

Page 14: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

2-2. Initial ProceduresPerform the procedures below to place theradiacmeter into operation:

a.

CAUTIONProtect the main probe, aux probe andx-ray probe window areas from sharpobjects which could damage the lightbarrier. The light barrier is very thin andeasily punctured which will cause theequipment to become inoperative. Keepthe main and auxiliary probe windowcovers (Figure 1-2) in place when theradiacmeter is not in use.

Operator Check for Main Probe.(1) Open the storage case and remove the

radiacmeter and main probe from their storageposition. Set the radiacmeter with main probeattached, upright on a flat surface.

(2) Loosen the two battery compartmentcover screws (Figure 2-1) and remove the batterycompartment cover.

(3) install two BA-30 batteries into theradiacmeter. Follow the plus and minus markingon the case for the proper battery position.Reinstall the battery compartment cover.

(4) Set the selector switch to the BATTposition and check the batteries.

(5) Loosen the probe handle retaining nut(Figure 2-1) and separate the main probe from theradiacmeter. Remove the main probe windowcover.

(6) Set the selector switch to the 10K posi-tion and place the main probe window area overthe check source (Figure 2-2) on the bottom of theradiacmeter. Fit the main probe and radiacmeterat a right angle to get as close as possible to thecheck source.

WARNINGThe check source used in this equip-ment contains Thorium (a radioactivemetal). Thorium is a hazardous material.Injury or disease may result if the checksource is not handled properly. Use ex-treme care not to touch, scratch, break,or remove the surface of the checksource while handling them. See thefront of this technical manual for firstaid procedures.

(7) Read the indicating meter when thecheck source and the main probe are in contact.

The reading should be 6000 + 1200 CPM if theequipment is operating properly.

b. Operator Check for X-Ray Probe.(1) Follow procedures in paragraph 2-2.a,

then set selector switch to OFF.(2) Disconnect the coil cord cable from the

main probe and connect to the x-ray probe (Figure2-3).

(3) Detach the probe handle from the mainprobe and attach to the x-ray probe (Figure 2-3).

(4) Set the selector switch to the 10K posi-tion and center the x-ray probe window as closeas possible over the check source on the bottomof the radiacmeter (Figure 2-4).

(5) Read the indicating meter when thecheck source and the main probe are in contact.The reading should be between 4,000 and 10,000counts per minute.

2-3. Monitoring Terrain, Supplies, andEquipment.

a. General. The main (or aux probe) and thex-ray probe are used to monitor terrain, supplies,or equipment. Remember that the window areasof each type probe are fragile and can be punc-tured or damaged easily.

b. Procedures for Using the Main Probe (orAux Probe). Adjust the radiacmeter and use theprocedure below for monitoring large open areas.In areas where space is limited, use the aux probe(Paragraph 2-4).

(1) Place the radiacmeter into operation byperforming the procedures in Paragragh 2-2,above.

(2) Determine the best configuration foruse and connect equipment as outlined below:

(a) Main Probe Attached. R a d i a c -meter can be used with the main probe attachedto the radiacmeter (Figure 1-1).

(b) Main Probe Detached. Remove themain probe from the radiacmeter by loosening themain probe handle retaining nut and separatingthe two units. Attach the carrying strap to theradiacmeter case and place the carrying straparound your neck or on your shoulder to aid incarrying.

(c) Main Probe Extended. Connect thehandle extension (Figure 1-1) to the main probe byremoving the handle from the main probe bodyand inserting the handle extension between thetwo.

(3) Set the selector switch to the 1K posi-tion and proceed with monitoring while watchingthe indicating meter.

2-2 Change 2

Page 15: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

NOTEIn certain situations, it is inconvenientto constantly watch the indicator meterfor radiation. In those cases, theoperator should wear the headset. Con-nect the headset to the headset connec-tor on the radiacmeter and listen for thesound of clicks generated by radiationdetected by the main probe (or auxprobe). When listening in an area of noradiation, random clicks (below 100CPM) are heard. As an area of radiationis detected by the probe, the clickscome much faster and are accom-panied by higher meter readings.

(4) When an area of radiation is detectedby the main probe (or aux probe), the CPM readingon the indicating meter will increase. Shift theselector switch to the 10K, 100K, and 1M posi-tions as the indicating meter needle moves off thescale.

NOTEWhen changing to higher measurementpositions, the indicating meter needlemight remain to the right (off the scale).In this case, press the METER RESETswitch.

c. Procedures for Using the X-Ray Probe. Per-form Operator Check of X-Ray Probe (Para. 2-2.b)and use the following procedure for monitoringareas suspected of low energy gamma radiationcontamination.

NOTEThere is no waiting time after connec-ting the x-ray probe.

(1) Slowly scan with the probe window 6 to12 inches from the suspected object or area.

(2) The extension handle may be attachedto the x-ray probe by removing the probe and in-serting the extension between the handle and theprobe.

(3) Operate on the most sensitive rangethat does not result in an off-scale meter reading.

2-4. Monitoring PersonnelThe aux probe is used to monitor personnel or tobe used in confined spaces for monitoring wherethe main probe cannot be used. The aux probe isinstalled in place of the main probe on the mainprobe handle prior to use.

TM 11-6665-245-12

a . R e m o v e t h e m a i n p r o b e f r o m t h eradiacmeter by loosening the handle retaining nutand sliding the two apart.

NOTEIn the following procedure, the photo-multiplier tube in the main probe handlewill be uncovered. It must not be ex-posed to any light at all when the equip-ment is OFF, or exposed to any light atall when the equipment is ON. Such ex-posure will damage the photomultipliertube and shorten its life. Take thefollowing precautions:

Change the main probe with auxprobe in a darkened room. Set theselector switch to OFF or removebatteries.

b. Remove two binder head 1/4 inch screws(Figure 2-5) from the main probe handle (below thecable connector). Retain the screws.

c . Grip the handle and the main probe body oneach side of where they separate (right abovewhere the screws were removed). Slowly pull thetwo apart using a twisting motion.

d. Remove the plastic plug from the aux probeand insert it into the large probe opening.

e . Slip the aux probe over the photomultipliertube exposed in c above and rotate while slowlypressing it onto the handle. Line up the holes inthe aux probe with the screw holes in the handle.Replace the two binder head screws in the han-dle.

WARNINGThe check source used in this equip-ment contains Thorium (a radioactivemetal). Thorium is a hazardous material.Injury or disease may result if the checksource is not handled properly. Use ex-treme care not to touch, scratch, break,or remove the surface of the checksource while handling them. See thefront of this technical manual for firstaid procedures.

f. Test the aux probe for light tightness asfollows:

(1) Perform initial procedures of installingbatteries, checking batteries, and placing the auxprobe against the check source as in paragraph2-2 to determine proper operation.

Change 2 2-3

Page 16: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

NOTEThe aux probe is not cal ibrated;therefore, there is no standard CPMvalue when using the check source.

(2) After determining proper operation ofradiacmeier, expose the aux probe window areato a light source while watching the indicatingmeter. Any light leaks will cause the meter toshow some CPM value. This value is an error,which must be eliminated before the radiacmetercan be used.

g. Monitor personnel using a systematic pro-cedure. Move the aux probe to cover all body

areas exposed to radiation. Move the probe slowlyand hold it close to the body but without touchingit. In most cases, it will be necessary to listen onthe headset rather than watching the indicatingmeter, unless two persons are doing the monitor-ing.

2-5. Equipment ShutdownAfter mission or equipment use, shut down equip-ment as follows:

a. Remove the batteries from the radiacmeterand store them in the storage case.

b. Place all accessory items into their properpositions in theclose the cover.

storage case (Figure 1-3) and

Figure 2-1. Operator’s Controls and Indicators

2-4 Change 2

Page 17: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Figure 2-2. Radiac Probe DT-224B/PDR-56 Positioned Over Check Source

Change 2 2-5

Page 18: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Figure 2-3. AN/PDR-56F with X-Ray Probe, DT-590A/PDR-56

2-6 Change 2

Page 19: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Figure 2-4. X-Ray Probe DT-590A/PDR-56 Positioned Over Check Source

Change 2 2-7

Page 20: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Figure 2-5. Aux Probe Installed on Main Probe Handle

2-8 Change 2

Page 21: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

CHAPTER 3OPERATOR MAINTENANCE INSTRUCTIONS

3-1. Scope of Maintenancea. The maintenance duties of the operator are

to perform a prescribed sequence of preventivema in tenance p rocedures . The p reven t i vema in tenance p rocedures p rov ide fo r thesystematic care, servicing, and inspection of theequipment to prevent the occurrence of troubleand to reduce downtime.

b. These checks and services are also tomaintain the equipment in a mission ready condi-tion. The checks and services for AN/PDR-56F areas follows:

(1) Routine services (Para. 3-3)(2) Cleaning (Para. 3-5)

3-2. TooIs, Materials, and EquipmentRequired for Maintenance

a. No equipment is required for operatormaintenance. Tool Kit, Electronic Equipment TK101/G is required by the operator.

b. The following cleaning materials will beuseful to the operator:

(1) Soap and water(2) Lint-free cloths(3) Glass cleaner(4) Small soft bristle brush

3-3. Routine ServicesRoutine services are checks and observationsperformed by the operator at all times. Routines e r v i c e s a r e n o t s c h e d u l e d p r e v e n t i v emaintenance checks and services.

a. Routines. The operator should perform thefollowing routines as necessary:

(1) Cleaning (Para. 3-5)(2) Check for cut or frayed cables.(3) Check for dented, bent, or broken com-

ponents.(4) Check to see that items not in use are

properly stowed.(5) Check for rusting.(6) Check controls for smooth operation.(7) Cover unused receptacles, where ap-

plicable.(8) Check for loose hardware and connec-

tors.(9) Check to see that nameplates are clean

and legible.(10) Check for completeness of equipment.

b. Items Requiring Routine Services.

(1) Storage Case(2) Radiacmeter, including battery com-

partment.(3) Main Probe(4) Aux Probe(5) X-Ray Probe(6) Headset(7) Extension Handle(8) Harness

3-4. Operator Preventive MaintenanceChecks and Services (PMCS)

There is no PMCS to be performed on Radiac SetAN/PDR-56F.

3-5. CleaningInspect all exposed surfaces of the equipment.These surfaces should be free of dust, dirt,grease, and fungus.

a. Use the lint-free cloth to remove dust andloose dirt.

CAUTIONDo not press on the radiacmeter in-dicating meter glass when cleaning; themeter may be damaged.

b. Using a cloth dampened (not wet) with soapand water, remove grease, fungus, and hard toremove dirt.

c. Use the soft bristle brush to remove dustand dirt from areas hard to reach with the clean-ing cloth.

3-6. TroubleshootingOperator troubleshooting procedure shall be asfollows:

a. With the radiacmeter in an operating mode,if the indicating meter on the front panel does notindicate, or exhibits a low reading, the operatorshould replace the batteries with new ones.

b. With the radiacmeter in an operating mode,if the needle on the indicating meter swingsbelow zero (to the left of zero), the operator shouldcheck to see if the batteries have been installedbackwards. If they have, the operator shouldreverse the battery positions and check theradiacmeter for proper operation.

c. If battery replacement or reversal cannotcorrect the problem, the equipment requires ahigher category of maintenance.

Change 2 3-1/(3-2 blank)

Page 22: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM

CHAPTER 4ORGANIZTIONAL MAINTENANCE INSTRUCTIONS

11-6665-245-12

Section I. TOOLS AND EQUIPMENT

4-1. Tools and Equipment Required 4-2. Materials Required for MaintenanceTools and equipment authorized at the organizational For a list of materials required forcategory of maintenance are as follows: organizational maintenance of the radiac

a. Tool Kit, Electronic Equipment TK-101/G. se t re fe r to append ix C .b. Multimeter AN/USM-223.

Section II. Repainting AND Refinishing INSTRUCTIONS

4-3. Preparation for Painting area.4-5. Touchup Painting

Remove rust and corrosion from metal surfaces bylightly sanding with fine sandpaper. Brush two coats of paint on the primed metal to prevent

it from further corrosion. Refer to the applicable clean-4-4. Priming ing and refinishing particles specified in SB 11-573 and

Apply one coat of zinc chromate primer to the sanded TB 43-0118.

Section III. TROUBLESHOOTING

4-6. General Troubleshooting Instructions The following visual inspections should be made before

Troubleshooting of the radiac set is based on the systemperforming the troubleshooting procedures in table 4-1:

a. Radiacmeter.operational check contained in the operatortroubleshooting procedure discussed in section 3-6. To (1) Make sure that the main probe coil cord is ful-

troubleshoot the Radiac Set, note any unusual perfor- ly connected to the front panel connector and tight.

maria or condition during the operational check. Look (2) Make sure that headset bayonet connector isfor the corresponding symptom in the troubleshooting fully plugged into the front panel connector and secure-chart (table 4-1) and perform the corrective measures in- Iy locked in place.dicated. If the corrective measures do not remedy the (3) Make sure that the batteries are properly in-trouble, or if the corresponding symptom is not listed, stalled.higher category of maintenance is required. (4) Make sure that the front panel selector switch4-7. Troubleshooting by Visual Inspection is in the desired ON position.

Symptom

Meter reads zero with rangeswitch at BATT.

Meter pointer swings belowzero.

No indication when testedwith a check source.

Front panel meter indicatesbut no audible sound inheadset.

Table 4-1. Troubleshooting Chart

Probable Trouble

a. Batteries dead ormissing.

b. Poor battery connection.c. Switch knob loose.

Batteries installed in reverseposition.a. Faulty probe.b. Faulty coil cord.Faulty headset.

Corrective Measures

a. Replace batteries.

b. Clean connections.c. Tighten switch knob set

screw.Reverse battery position.

a. Replace probe.b. Replace coil cord.Replace headset.

Change 1 4-1

Page 23: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Section IV. MAINTENANCE OF THE RADIAC SET

4-8. Maintenance of the Radiacmetera. Headset BNC Type Connector Cap Re-

placement. This connector is locatedjust below the indicating meter on theleft-hand side of the radiacmeter frontpanel (fig. 4-1). If the connector capis damaged or missing, replace as follows:

(1) Using a screwdriver, remove the screw that re-tains the cap chain to the front panel. Do not discard thescrew.

(2) Twist the cap, mounted on the BNC connec-tor, counterclockwise to unlock it from the connector,and lift it off the connector.

(3) Plug a new cap firmly into the connector, andtwist it clockwise to lock it in place.

(4) Place the screw through the eyelet on the freeend of the cap chain, and reinstall the screw into theradiacmeter front panel.

b. Selector Switch Knob. Located at the centerright of the radiacmeter front panel (fig 4-1). If thisknob becomes loose, damaged or is missing , replace ofretighten as follows:

(1) Determine what scale the radiacmeter is set toby observing the indicating meter scale.

(2) If the knob is missing, place a new knob onthe selector switch shaft. If the knob is damaged, use asmall blade screwdriver to loosen the screw in the knoband remove the damaged knob. Replace with a newknob.

(3) Line up the knob with the front panel markingthat agrees with the indicating meter scale (OFF, BATT,1M, 100K, or 1K).

(4) Using the small blade screwdriver, tighten theknob screws so that the knob position is in agreementwith the meter scale.

4-9. Preparation for Storage or Shipmenta. Preparation for Storage. The following items

must be completed or considered prior to storing theequipment.

(1) Security of the stored items is required. The

stored area must prevent items from being stolen.(2) Items stored must be protected from the

weather. Covered storage is required.(3) Items to be stored must be in good working

order. Equipment that is inoperative cannot be stored.Perform an operation check (para 2-2) of the equip-ment prior to storage. Remove all batteries from theequipment and storage case prior to storage.

(4) In the case of items put into administrativestorage (1-45 days), the storage area must be accessible.The equipment in storage must be able to be put intooperation within 24 hours.

b. Preparation for Shipment. The radiac set isshipped in its storage case without any internal packingor cushioning material. The storage case itself must beprotected during shipment by packing it in an oversizedcorrugated fiber board box. The space inside the pack-ing box, at least 1 to 2 inches all around the storage case,must be filled with cushioning and blocking material toprevent movement. The packing box should then be sur-rounded with some form of vapor barrier and sealed.Next, the packing box with vapor barrier in place shouldbe placed inside another corrugated fiber board box andsealed.

c. Battery Compartment Gasket Replacement.Should the battery compartment cover gasket (fig. 4-1)become detached or damaged, replace as follows:

(1) Remove any portion of the old gasket fromthe battery compartment cover by peeling or lightlyscraping.

(2) Clean the cover of all residue using soap andwater and a cleaning cloth. This surface must bethoroughly clean and dry.

(3) Apply a light coating of adhesive (item 6,appx D) to both the gasket and the batterycompartment cover.

(4) Place the gasket firmly onto the battery com-partment cover, in the correct position.

(5) Wait at least 30 minutes before reinstallingcover.

4-2 Change 1

Page 24: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

Figure 4-1. Battery compartment cover, exploded view.

4 - 3

Page 25: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

APPENDIX AREFERENCES

AR 70-58 Packaging Improvement Report.

DA Pam 738-750 The Army Maintenance Management System (TAMMS)

SB 11-573 Painting and Preservation of Supplies Available for Field Use for ElectronicsCommand Equipment.

TB 43-0118 Field Instructions for Painting and Preserving Electronics Command Equip-ment Including Camouflage Pattern Painting of Electrical EquipmentShelter.

DA Pam 310-1 Consolidated Index of Army Publications and Blank Forms.

TM 750-244-2 Procedures for Destruction of Electronics Materiel to Prevent Enemy Use(Electronics Command).

Change 2 A-1/(A-2 blank)

Page 26: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

APPENDIX BCOMPONENTS OF END ITEM LIST

B-1. ScopeThis appendix lists integral components of andbasic issue items for the AN/PRD-56F to help youinventory items required for safe and efficientoperation.

B-2. GeneralThis Components of End Item List is divided intothe following sections:

a. Section Il. Integral Components of the EndItem. These items, when assembled, comprise theAN/PDR-56F and must accompany it whenever itis transferred or turned in. The illustration (FigureB-1) will help you identify these items.

b. Section Ill. Basic Issue Items. Not ap-plicable.

B-3. Explanation of Columnsa. Il lustration. This column is divided as

follows:(1) Figure number. Indicates the figure

number of the illustration on which the item isshown.

(2) Item number. The number used to iden-tify item called out in the illustration.

b. National Stock Number. Indicates the na-tional stock number assigned to the item andwhich will be used for requisitioning.

c. Part Number. Indicates the primary numberused by the manufacturer, which controls thedesign and characteristics of the item by meansof its engineering drawings, specifications, stan-dards, and inspection requirements to identify anitem or range of items. Following the part number,

the Federal Supply Code for Manufacturers(FSCM) is shown in parentheses.

d. Description. Indicates the Federal itemname and, if required, a minimum description toidentify the item.

e. Location. The physical location of eachitem listed is given in this column. The lists aredesigned to inventory all items in one area of themajor item before moving on to an adjacent area.

f. Usable on Code. Not applicable.

Code Used On

g. Quantity Required (Qty Reqd). This columnlists the quantity of each item required for a com-plete major item.

h. Quantity. This column is left blank for useduring an inventory. Under the Rcvd column, listthe quantity you actually receive on your majoritem. The Date columns are for your use when youinventory the major item at a later date; such asfor shipment to another site.

B-4. Special InformationNational Stock Numbers (NSNs) that are missingfrom Section II have been applied for and will beadded to this TM by future change/revision whenthey are entered in the Army Master Data File(AMDF). Until the NSNs are established andpublished, submit exception requisitions to: Com-mander, US Army Communications and Elec-tronics Materiel Readiness Command, ATTN: AM-SEL-MM, Fort Monmouth, NJ 07703-5006 for thepart required to support your equipment.

Change 2 B-1

Page 27: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

Figure B-1. Components of Radiac Set

TM 11-6665-245-12

B-2 Change 2

Page 28: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Section Il. INTEGRAL COMPONENTS OF END ITEMRADIAC SET AN/PDR-56F

(1) (2) (3) (4) (5) (6)Illustration

(7)

(A) (B) National Description Location Usable QtyFig. Item Stock

QuantityOn Reqd.

No. No. Number Part Number (FSCM) Code Rcvd Date

B-1 1 Carrying Case (96696) 1Assy D4609

2 Auxiliary Probe (96696) 1Assy B4177

3 Headphone, H-43 (96696) 1B/U C3898

4 Carrying Strap (96696) 1Assy B1031

5 Probe Handle (96696) 1ExtensionB1112

6 Radiacmeter (96696) 1Assy D3853

7 Main Probe (96696) 1Assy D4179

8 X-Ray Probe (96696) 1Assy 07283

DRSEL-MA Form 6010, (1 MAR 77) (Edition of 1 JUN 76 is obsolete) HISA-FM 545-77

Change 2 B-3/(B-4 blank)

Page 29: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

APPENDIX CMAINTENANCE ALLOCATION

Section I. INTRODUCTION

C-1. General.This appendix provides a summary of the maintenanceoperations for AN/PDR-56F. It authorizes categoriesof maintenance for specific maintenance functions onrepairable items and components and the tools andequipment required to perform each function. This ap-pendix may be used as an aid in planning maintenanceoperations.

C-2. Maintenance Function.Maintenance functions will be limited to and defined asfollows:

a. Inspect. To determine the serviceability of anitem by comparing its physical, mechanical, and/orelectrical characteristics with established standardsthrough examination.

b. Test. To verify serviceability and to detect inci-pient failure by measuring the mechanical or electricalcharacteristics of an item and comparing those charac-teristics with prescribed standards.

c. Service. Operations required periodically tokeep an item in proper operating condition, i.e., toclean (decontaminate), to preserve, to drain, to paint, orto replenish fuel, lubricants, hydraulic fluids, or com-pressed air supplies.

d. Adjust. To maintain, within prescribed limits,by bringing into proper or exact position, or by settingthe operating characteristics to the specified parameters.

e. Align. To adjust specified variable elements of anitem to bring about optimum or desired performance.

f. Calibrate. To determine and cause corrections tobe made or to be adjusted on instruments or testmeasuring and diagnostic equipments used in precisionmeasurement. Consists of comparisons of two in-struments, one of which is a certified standard of knownaccuracy, to detect and adjust any discrepancy in the ac-curacy of the instrument being compared.

g. Install. The act of emplacing, seating, or fixinginto position an item, part, module (component orassembly) in a manner to allow the proper functioningof the equipment or system.

h. Replace. The act of substituting a serviceable liketype part, subassembly, or module (component or as-sembly) for an unserviceable counterpart.

i. Repair. The application of maintenance services(inspect, test, service, adjust, align, calibrate, replace) orother maintenance actions (weilding, grinding, riveting,straightening, facing, remachining, or resurfacing) torestore serviceability to an item by correcting specificdamage, fault, malfunction, or failure in a part, sub-

assembly, module (component or assembly), end item,or system.

j. Overhaul. That maintenance effort (service/ac-tion) necessary to restore an item to a completely ser-viceable/operational condition as prescribed by mainte-nance standards (i.e., DMWR) in appropriate technicalpublications. Overhaul is normally the highest degreeof maintenance performed by the Army. Overhaul doesnot normally return an item to like new condition.

k. Rebuild. Consists of those services/actionsnecessary for the restoration of unserviceable equip-ment to a like new condition in accordance with originalmanufacturing standards. Rebuild is the highest degreeof materiel maintenance applied to Army equipment.The rebuild operation includes the act of returning tozero those age measurements (hours, miles, etc.) con-sidered in classifying Army equipments/components,

C-3. Column Entries.a. Column 1, Group Number. Column 1 lists

group numbers, the purpose of which is to identify com-ponents, assemblies, subassemblies, and modules withthe next higher assembly.

b. Column 2, Component/Assembly. Column 2contains the noun names of components, assemblies,subassemblies, and modules for which maintenance isauthorized.

c. Column 3, Maintenance Functions. Column 3lists the functions to be performed on the item listed incolumn 2. When items are listed without maintenancefunctions, it is solely for purpose of having the groupnumbers in the MAC and RPSTL coincide.

d. Column 4, Maintenance Category. Column 4specifies, by the listing of a “work time” figure in theappropriate subcolumn(s), the lowest level ofmaintenance authorized to perform the function listedin column 3. This figure represents the active time re-quired to perform that maintenance function at the in-dicated category of maintenance. If the number or com-plexity of the tasks within the listed maintenance func-tion vary at different maintenance categories, ap-propriate “work time” figures will be shown for eachcategory, The number of task-hours specified by the“work time” figure represents the average time requiredto restore an item (assembly, subassembly, component,module, end item or system) to a serviceable conditionunder typical field operating conditions. This time in-cludes preparation time, troubleshooting time, andquality assurance/quality control time in addition to thetime required to perform the specific tasks identified for

C-1

Page 30: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

the maintenance functions authorized in the mainte-nance allocation chart. Subcolumns of column 4 are asfollows:

C-Operator/CrewO-OrganizationalF-Direct SupportH-General SupportD-Depot

e. Column 5, Tools and Equipment. Column 5specifies by code, those common tool sets (not in-dividual tools) and special tools, test, and supportequipment required to perform the designated function.

f. Column 6, Remarks. Column 6 contains analphabetic code which leads to the remark in section IV,Remarks, which is pertinent to the item opposite theparticular code.

C-4. Tool and Test Equipment Re-quirements (Sect. Ill).a. Tool or Test Equipment Reference Code. The

numbers in this column coincide with the numbers used

in the tools and equipment column of the MAC. Thenumbers indicate the applicable tool or test equipmentfor the maintenance functions.

b. Maintenance Category. The codes in this col-umn indicate the maintenance category allocated the -

tool or test equipment.c. Nomenclature. This column lists the noun name

and nomenclature of the tools and test equipment re-quired to perform the maintenance functions.

d. National/NATO Stock Number. This columnlists the National/NATO stock number of the specifictool or test equipment.

e. Tool Number. This column lists the manufac-turer’s part number of the tool followed by the FederalSupply Code for manufacturers (5-digit) in parentheses.

C-5. Remarks (Sect. IV.)a. Reference Code. This code refers to the ap-

propriate item in section II, column 6.b. Remarks. This column provides the required

explanatory information necessary to clarify items ap-pearing in section II.

(Next printed page is 44)

C - 2

Page 31: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

00

01

0101

010101

010102

010103

0102

02

0201

020101

03

TM 11-6665-245-12

SECTION Il. MAINTENANCE ALLOCATION CHARTFOR

RADIAC SET AN/PDR-56F

Change 2 C-3

Page 32: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

05

0401

04

0301

TM 11-6665-245-12

SECTION Il. MAINTENANCE ALLOCATION CHARTFOR

RADIAC SET AN/PDR-56F

C-4 Change 2

Page 33: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Section Ill. TOOL AND TEST EQUIPMENT REQUIREMENTSFOR

RADIAC SET AN/PDR-56F

Change 2 C-5

Willie Gaddis
Page 34: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

Section IV. REMARKS

REFERENCECODE REMARKS

A Radiacmeter, Main Probe Assembly, Emitter Follower Assembly andPhotomultiplier Tube are calibrated as a unit; any replacement will requirerecalibration utilizing the AN/UDM-7 Radiac Calibrator.

B Repair or Replacement of components requires recalibration.

C Repair by replacement of scintillation screen and cover assembly (RequiresLight Leak Test).

D Replacement requires recalibration and Light Leak Test.

E Repair or replacement requires checking using Emitter Follower.

F Use Pliobond Adhesive.

G Replace Window Guard Plastic only.

H Repair includes replacement of BNC Cap, Selector Switch Knob and BatteryCompartment Cover Gasket.

I Repair by replacement of bulb.

J Radioactive Source must be disposed of as radioactive waste (AR 385-11).

K Repair by replacement of source or source frame.

L Replace cap ring assembly and end cap assembly only.

M Repair or replacement requires calibration check of x-ray probe with variablex-ray source.

C-6 Change 2

Page 35: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

APPENDIX DEXPENDABLE SUPPLIES AND MATERIALS LIST

Section I. INTRODUCTION

D-1. ScopeThis appendix lists expendable supplies and materialsyou will need to operate and maintain the AN/PDR-56F. These items are authorized to you by CTA 50-970,Expendable Items (Except Medical, Class V, RepairParts, and Heraldic Items).

D-2. Explanation of Columnsa. Column 1 — Item number. This number is

assigned to the entry in the listing and is referenced inthe narrative instructions to identify the material(e.g., "Use cleaning compound, item 5, App. D").

b. Column 2 — Level. This column identifies thelowest level of maintenance that requires the listed item.

C-Operator/CrewO-Organizational Maintenance/Aviation Unit

Maintenance

F—Direct Supporttermediate Maintenance

H—General Support

Maintenance/Aviation In-

Maintenancec. Column 3—National Stock Number. This is the

National stock number assigned to the item; use it to re-quest or requisition the item.

d. Column 4—Description. Indicates the Federalitem name and, if required, a description to identify theitem. The last line for each itern indicates the FederalSupply Code for Manufacturer (FSCM) in parenthesesfollowed by a part number.

e. Column 5—Unit of Measure (U/M). Indicatesthe measure used in performing the actual maintenancefunction. This measure is expressed by a two-characteralphabetical abbreviation (e.g., ea. in, pr). If the unit ofmeasure differs from the unit of issue, requisition thelowest unit of issue that will satisfy your requirements.

(Next printed page is D-3)

D-1

Page 36: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

TM 11-6665-245-12

SECTION II EXPENDABLE SUPPLIES AND MATERIALS LIST

D-3

Page 37: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

By Order of the Secretary of the Army:

Official:

EDWARD C. MEYERGeneral, United States Army

Chief of Staff

J. C. PENNINGTONMajor General, United States Army

The Adjutant General

Distribution:

To be distributed in accordance with DA Form 12-50, Organizational maintenance requirements forAN/PDR-60.

U.S. GOVERNMENT PRINTING OFFICE : 1989 - 242 - 451 (5695)

Page 38: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT
Page 39: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT
Page 40: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT
Page 41: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

THE METRIC SYSTEM AND EQUIVALENTS

Page 42: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

PIN: 047703-002

Page 43: OPERATOR AND ORGANIZATIONAL MAINTENANCE MANUAL RADIAC SET ... · (NSN 6665-00-211-6895) This copy is a reprint which includes current pages from Changes 1 and 2. HEADQUARTERS, DEPARTMENT

This fine document...

Was brought to you by me:

Liberated Manuals -- free army and government manuals

Why do I do it? I am tired of sleazy CD-ROM sellers, who take publicly available information, slap “watermarks” and other junk on it, and sell it. Those masters of search engine manipulation make sure that their sites that sell free information, come up first in search engines. They did not create it... They did not even scan it... Why should they get your money? Why are not letting you give those free manuals to your friends?

I am setting this document FREE. This document was made by the US Government and is NOT protected by Copyright. Feel free to share, republish, sell and so on.

I am not asking you for donations, fees or handouts. If you can, please provide a link to liberatedmanuals.com, so that free manuals come up first in search engines:

<A HREF=http://www.liberatedmanuals.com/>Free Military and Government Manuals</A>

– SincerelyIgor Chudovhttp://igor.chudov.com/

– Chicago Machinery Movers