24
06/11/22 Operational Amplifier Characterization Chapter 3

Operational Amplifier Characterization

  • Upload
    wes

  • View
    50

  • Download
    2

Embed Size (px)

DESCRIPTION

Operational Amplifier Characterization. Chapter 3. Contents. Input offset voltage Input bias and input offset currents Output impedance Differential and common-mode input impedances DC gain, bandwidth, gain-bandwidth product Common mode and power supply rejection ratios - PowerPoint PPT Presentation

Citation preview

Page 1: Operational Amplifier Characterization

04/21/23

Operational Amplifier CharacterizationChapter 3

Page 2: Operational Amplifier Characterization

Contents Input offset voltage Input bias and input offset currents Output impedance Differential and common-mode input impedances DC gain, bandwidth, gain-bandwidth product Common mode and power supply rejection ratios Higher frequency poles, settling time Slew rate Noise in operational amplifier circuits

Page 3: Operational Amplifier Characterization

The Ideal Op-amp Input resistance, Rin Output resistance, Ro = 0 Open loop voltage gain, G Bandwidth B Vo = 0 when V+ = V- (i.e., the common – mode gain is

zero and the CMRR approaches infinity)

Page 4: Operational Amplifier Characterization

The Typical Op-amp Input resistance, Rin 2 M, not Output resistance, Ro = 75 , not 0 Open loop voltage gain, G 1x105, not Bandwidth B 1 MHz, not Offset current, Iio = 20 nA

Offset voltage, Vio = 2 mV Slew rate, SR = 0.7 V/ms

Page 5: Operational Amplifier Characterization

Input offset voltage When voltage at both inputs is zero, the output should

be zero Op amps do not have perfectly balanced input stages

owing to manufacturing variations The difference in input voltages necessary to bring the

output to zero is called the input offset voltage. Usually op-amps make provision for trimming the input

offset voltage to zero

Page 6: Operational Amplifier Characterization

Effect

Vi0 and the large value of the open-loop gain of the op-amp act to drive V0 to negative saturation.

The magnitude and polarity of Vi0 varies from op amp to op amp. So for some op amp, the output will be driven to +Vsat and others will be driven to -Vsat.

Page 7: Operational Amplifier Characterization

Measurement

Since Ei = 0V, V0 should equal 0V. The error in V0 due to Vi0 is given by V0 = error voltage due to Vi0 = Vi0(1 + Rf/Ri)

The output error voltage results whether the circuit is used as an inverting or as a noninverting amplifier.

A bias-current compensating resistor (a resistor in series with the (+) input) has no effect on this type of error in the output voltage due to Vi0.

Page 8: Operational Amplifier Characterization

Practical side of input offset voltage For 411 and 741, we use a pot.

between pins 1 and 5, with the wiper connected to -Vcc as offset null

typical offset voltages:411 => 0.8 mV741 => 2 mV

Page 9: Operational Amplifier Characterization

Input bias current Although ideal op-amp inputs draw no current, some bias

current must enter each input terminal in the actual case. Ibias is the base current of the input transistor, and a

typical value is 2 A. When the source impedance is low, Ibias has little effect,

since it causes a relatively small change in input voltage. However, in high-impedance circuits, a small current can lead to a large voltage.

Page 10: Operational Amplifier Characterization

Modeling

The bias current can be modeled as two current sinks. The values of these sinks are independent of the source impedance.

The bias current is defined as the average value of the two current sinks. Thus Ibias = (IB+ + IB-)/2

The difference between the two sink values is known as the input offset current, Iio and is given by Iio = IB+ - IB-.

Page 11: Operational Amplifier Characterization

Effect of (-) input bias current

Output voltage should be zero ideally: The fact that a voltage component will be measured is due strictly to IB-

For simplicity, assume that the input offset voltage is 0V The bias current is furnished from the output terminal.

Since negative feedback forces the differential input voltage to 0V, V0 must rise to supply the voltage drop across Rf. Thus, the output voltage error due to IB- is found from V0 = RfIB-.

IB+ flows through 0, so it causes no voltage error.

Page 12: Operational Amplifier Characterization

Effect of (+) input bias current

V0 should ideally equal 0V. However, the positive input bias current IB+ flows through the internal resistance of the signal generator.

IB+ sets up a voltage drop of RG IB+ across resistor RG and applies it to the (+) input.

The differential input voltage of 0V, so the (-) input is also at RGIB+

Since there is 0 resistance in the feedback loop, V0 equals RGIB+.

Page 13: Operational Amplifier Characterization

Reducing the effect of input bias current

It is possible to reduce the output dc voltage caused by the input bias current by connecting the op-amp as shown in fig

This method consists of introducing a resistance R3 in series with the noninverting input lead

From a signal point of view, R3 has a negligible effect. The appropriate value for R3 can be determined by analyzing the circuit

IB+ = IB- = IB, results inR3 = R2/(1 + R2/R1) = R1R2/(R1 + R2)

Page 14: Operational Amplifier Characterization

Output Impedance Typical values for the open-loop output resistance R0

are 75 to 100 We wish to find the output resistance of a closed-loop

amplifier To do this, we short the signal source, which makes the

inverting and non-inverting configurations identical and apply a test voltage Vx to the output

Then the output resistance Rout Vx/I can be obtained by straightforward analysis of the circuit

Page 15: Operational Amplifier Characterization

V = -Vx R1/(R1 + R2) = -Vx

I = Vx/(R1 + R2) + (Vx - AV)/R0

= Vx/(R1 + R2) + (1 + A)Vx/R0

Thus1/Rout = I/Vx = 1/(R1 + R2) + (1 + A)/R0

where the constant is defined as = R1/(R1 + R2)

Page 16: Operational Amplifier Characterization

This means that the closed-loop output resistance is composed of two parallel components,Rout = [R1 + R2] || [R0/(1 + A)]

Normally R0 is much smaller than R1 + R2, resulting inRout R0/(1 + A)

The closed-loop output resistance is smaller than the op amp open-loop output resistance by a factor equal to the amount of feedback, 1 + A.

Rout R0/A for A>>1

Page 17: Operational Amplifier Characterization

Differential and Common mode input impedance

As shown in fig, the op amp has a differential input resistance Rid seen between the two input terminals.

In addition, if the two input terminals are tied together and the input resistance (to ground) is measured, the result is the common-mode input resistance Ricm.

Typical values for the input resistances of general-purpose op amps using bipolar junction transistors are Rid = 1 M and Ricm = 100 M.

Page 18: Operational Amplifier Characterization

DC gain, bandwidth, gain-bandwidth product

The differential open-loop gain of op amp is not infinite; rather, it is finite and decreases with frequency.

Fig shows a plot for |A|, with the numbers typical of most general-purpose op amps (such as 741).

Although the gain is quite high at dc and low frequencies, it starts to fall off at a rather low frequency (10 Hz in this example).

The uniform -20 dB/decade gain rolloff shown is typical of internally compensated op amps.

Page 19: Operational Amplifier Characterization

Common mode and power supply rejection ratios

The power supply rejection ratio (PSRR) is a measure of the ability of the op-amp to ignore changes in the power supply voltage.

The PSRR is the ratio of the change in Vo to the total change in power supply voltage.

For example, if the positive and negative supplies vary from 5 V to 5.5 V, the total change is 11 – 10 =1 V. PSRR is usually specified in microvolts per volt or sometimes in decibels. Typical op-amps have a PSRR of about 30 V / V

Page 20: Operational Amplifier Characterization

Frequency Compensation Many op amps are internally compensated. Internal frequency compensation capacitor prevents the op

amp from oscillating by decreasing the op amp's gain as frequency increases. Otherwise there would be sufficient gain and phase shift at some high frequency where enough output signal could be fed back to the input and cause oscillations.

The trade-off for frequency stability are limited small-signal bandwidth, slow slew rate, and reduced power bandwidth.

Page 21: Operational Amplifier Characterization

Slew Rate Slew rate is a measure of the speed at which the output

signal can change. Slew rate is related to the power bandwidth, fp, which is

defined as the frequency at which a sine wave output, at rated output voltage, starts to experience distortion.

If the output signal is V0 = V sin 2fpt, Then the maximum slope is SR = dV / dt |max = 2fpV

The power bandwidth is given by fp = SR / 2V

Page 22: Operational Amplifier Characterization

Noise in op-amp circuits

Electronic circuits are susceptible to noise and op-amp is not an exception. Apart from external noise, op-amp has internal noise sources like bias current, drift and internal components.

Noise is also amplified by op-amp, just as offset voltage and signal voltage.

Even if there were no external noise, there would still be noise in the output voltage caused by the op amp. This internal op amp noise is modeled most simply by a noise voltage source En.

Page 23: Operational Amplifier Characterization

The 741 op amp has 2 V of total noise over a frequency of 10 Hz to 10 kHz.

This noise voltage is valid for source resistors (Ri) between 100 and 20 k.

The noise voltage goes up directly with Ri once Ri exceeds 20 k. Thus Ri should be kept below 20 k to minimize noise in the output.

Page 24: Operational Amplifier Characterization

Measures to minimize internal noise Keep series input resistors and the feedback resistors

as low in value as practically possible to satisfy circuit requirements

Bypass feedback resistor with a small capacitor (3 pF) which will reduce noise gain at higher frequencies

Never connect a capacitor across the input resistor or from (-) input to ground. There will always be a few pF of stray capacitance from (-) input to ground due to wiring