175070085 EN
Hydraulic power unit P 630 SG
(Translation of the original operating instructions)
replaces 11.2013
Operating instructions for rescue equipment
Edition 02.2017
2
Content Page1. Dangerclassifications 4
2. Productsafety 5
3. Intendeduse 9
4. Powerunitdesignation 10
5. Functionaldescription 10 5.1 General information 10 5.2 Installation of the power unit 11 5.3 Motor 12 5.4 Valves 13 5.5 Pumps 14 5.6 Frame with side sections 14 5.7 Connection to the rescue equipment 14
6. Connectingthehoses/devices 15 6.1 Coupling the mono-couplings 15
7. Set-upandcommissioning 17 7.1 Set-up 17 7.2 Commissioning 17
8. Operation 19 8.1 Starting the engine 19 8.2 Turningtheengineoff 20 8.3 Refuelling 20 8.4 Controlling the valves 21
9. Dismantlingtheequipment/deactivationfollowingoperation 22
10.Tests 23 10.1 Recommended test intervals 23 10.2 Visual and function check 24
11.Maintenanceandrepair 25 11.1 General information 25 11.2 Service work on the hydraulic unit 26 11.3 Additional service work 28
3
Content Page12.Faultanalysis 33
13.Technicaldata 38 13.1 Power Unit 38 13.2 Noise emissions (Sound pressure level) 40 13.3 Sparking plug 41 13.4 Sparking plug spanner 41 13.5 Fuel 41 13.6 Engine oil 42 13.7 Hydraulicfluidrecommendation 42 13.8 Operating and storage temperature range 42
14.ECDeclarationofConformity 43
4
Wearahelmetwithafaceguard
Wearprotectivegloves
Wearsafetyshoes
Properrecycling
Protecttheenvironment
Readandfollowoperatinginstructions
Wedifferentiatebetweenvariousdifferentcategoriesofsafetyinstructions.Thetableshownbelowshowsyouanoverviewoftheassignmentofsymbols(pictograms)andsignalwordstothespecificdangerandthepossibleconsequences.
1. Danger classifications
Pictogram Damage / injury to Key word Definition Consequences
Persons
DANGER! Immediatedanger Deathorsevereinjury
WARNING!Potentiallydangeroussituation
Potentialdeathorseriousinjury
CAUTION! Lessdangeroussituation
Minororslightinjury
Property
ATTENTION!Dangerofdamage
toproperty/environment
Damagetotheequipment,
damagetotheenvironment,damagetosurroundings
- NOTE
Handlingtipsandotherimportant/usefulinformation
andadvice
Noinjury/damagetopersons/environment/
device
5
2. Product safetyLUKAS products are developed andmanufactured to ensure the best performance andqualitywhenusedasintended.Thesafetyoftheoperatoristhemostimportantconsiderationinproductdesign.Furthermore,theoperatinginstructionsareintendedtohelpinusingLUKASproductssafely.Thegenerallyapplicablelegalandotherbindingregulationspertainingtothepreventionofaccidentsandprotectionoftheenvironmentapplyandaretobecompliedwithinadditiontotheoperatinginstructions.Theequipmentmustonlybeoperatedbypersonswithappropriate training in thesafetyaspectsofsuchequipment–otherwise,thereisadangerofinjury.Wewouldliketopointouttoallusersthattheyshouldreadcarefullytheoperatinginstructionsandtheinstructionscontainedthereinbeforetheyusetheequipment,andthattheyshouldcarefullyfollowsuch.Wefurtherrecommendyouhaveaqualifiedtrainershowyouhowtousetheproduct.
CAUTION!The operating instructions for the hoses, accessories and the connecteddevicesmustalsobeheeded!
Evenifyouhavealreadyreceivedinstructiononhowtousetheequipment,youshouldstillreadthroughthefollowingsafetyinstructionsagain.
CAUTION!Ensure that the accessories and connected equipment are suitable for themaximumoperatingpressure!
Pleaseensurethatnobodypartsorclothinggetstuckbetweenthevisiblymovingparts.
Immediatelyreportanychangesthatoccur(includingchangesinoperatingbehaviour)totheappropriatepersons/departments!Ifnecessary,theequipmentistobeshutdownimmediatelyandsecured!
Wearprotectiveclothing,safetyhelmetwithvisor,safetyshoesandprotectivegloves.
Checktheequipmentforvisibleflawsordamagebeforeandafteruse.
Workingundersuspendedloadsisnotpermittedwheresuchloadsarebeingliftedonlybymeansofhydraulicdevices.Ifthisworkisunavoidable,suitablemechanicalsupportsarealsorequired.
Checkalllines,hosesandscrewedconnectionsforleaksandexternallyvisibledamage,andrepairimmediately!Escapinghydraulicfluidcancauseinjuriesandfires.
6
Intheeventofmalfunctions,immediatelydeactivatethedeviceandsecureit.Repairthefaultimmediately.
Donotcarryoutanychanges(additionsorconversions)totheequipmentwithoutobtainingtheapprovalofLUKASbeforehand.
Observeallsafetyanddangerinformationonthedeviceandintheoperatinginstructions.
Allsafetyanddangerinformationonthedevicemustalwaysbecompleteandinalegiblecondition.
Pleaseensurethatallsafetycoversarepresentontheequipmentandthattheyareinproperandadequatecondition.
Anymodeofoperationwhichcompromisesthesafetyand/orstabilityofthedeviceisforbidden!
Safetydevicesmustneverbedisabled!
Themaximumoperatingpressuresetontheequipmentmustnotbechanged!
Makesurebeforeswitchingon/startingupthedeviceandduringitsoperation,thatthiswillputnooneindanger.
Observeallintervalsforrecurringtestsand/orinspectionsthatareprescribedorstatedintheoperatinginstructions.
Whenworkingclosetolivecomponentsandcables,suitablemeasuresmustbetakentoavoidcurrenttransfersorhigh-voltagetransferstotheequipment.
OnlyoriginalLUKASaccessoriesandsparepartsaretobeusedforrepairs.Whenworkingwiththisequipmentorwhentransportingit,ensurethatyoudonotgetcaughtupinthehoseorcableloopsandtrip.
Thebuild-upofstaticchargeandthereforepossiblesparkingmustbeavoidedwhenhandlingthedevice.
Donottouchtheengineandexhaustsystemwhenrunningwithcombustionenginepumpsbecauseofthedangerofburning.
Motorisedpumpsmustnotbeoperatedinareasatriskofexplosion!
Combustionenginesmustnotbeoperatedinenclosedspacesbecauseofthedangerofpoisoningand/orsmothering.
7
Keepcombustionenginesandtheirfuelsawayfromsourcesofignitionsinceotherwisetherewillbeadangerofexplosion.
Alldamagedelectricalcomponentse.g.scorchedcables,etc.aretobereplacedimmediately!
Inordertopreventthedangeroffire,youshouldensureadequateventilationwhenoperatingcombustionenginesandyoumustkeepasafetydistanceofatleast1m(39.4 in.)towallsandotherscreens.
Damagetoelectricalcomponentsmustonlyberepairedbyaqualifiedelectricianincompliancewithallapplicablenationalandinternationalsafetyguidelinesandregulations.
Makesurethatthecombustionenginesarealwaysstandingonasflatandhorizontalasurfaceaspossibletopreventfuelfromleakingout.
Whensettinguptheunits,youmustmakesurethattheyarenotimpairedbytheinfluencesofextremetemperatures.
Theequipmentisfilledwithhydraulicfluid.Thishydraulicfluidcanbedetrimentaltohealthifitisswallowedoritsvapourisinhaled.Directcontactwiththeskinmustbeavoidedforthesamereason.Also,whenhandlinghydraulicfluid,notethatitcannegativelyaffectbiologicalsystems.
Whenworkingwithorstoringtheequipment,ensurethatthefunctionandthesafetyoftheequipmentarenotimpairedbytheeffectsofsevereexternaltemperaturesorthattheequipmentisdamagedinanyway.Pleasenotethattheequipmentcanalsoheatupoveralongperiodofuse.
Makesurethereisadequatelightingwhileworking.
Beforetransportingtheequipment,alwaysensurethattheaccessoriesarepositionedinsuchawaythattheycannotcauseanaccident.
Alwayskeeptheseoperatinginstructionseasilyaccessibleattheplaceofoperation.
Ensuretheproperdisposalofallremovedparts,leftoveroil,hydraulicfluidandpackagingmaterials.
Ifyouspillanyfuelwhenusingcombustionengines,youmustremovethespilledfuelcompletelybeforestartingtheengine.
Refuellingwhilsttheengineisrunningisstrictlyprohibited!
8
The generally applicable, legal and other binding national and international regulationspertainingtothepreventionofaccidentsandprotectionoftheenvironmentapplyandaretobeimplementedinadditiontotheoperatinginstructions.
WARNING/CAUTION!Thedeviceisintended exclusively for the purpose stated in the operating instructions (see chapter "Proper Use"). Any other use is not in accordance with its designated use.Themanufacturer/supplierisnotliableforanydamagesresultingfromimproperuse.Theuserbearssoleresponsibilityforsuchuse.Proper use includes observance of the operating instructions and compliance with theinspectionandmaintenanceconditions.
Never work in a fatigued or intoxicated state!
WARNING/CAUTION!Ifyoustillinjureyourselfonthehydraulicunit,cleanthewoundimmediatelyandconsultadoctortohaveitattendedto!Ifyougethydraulicfluidinyoureye,rinseitimmediatelyseveraltimeswithclear,cleanwaterandconsultadoctor!Also,ifyouswallowhydraulicfluidyoushouldconsultadoctor!
9
3. Intended use
You can obtain accessories and replacement parts for the rescue apparatus from yourauthorisedLUKASdealer!
WARNING/CAUTION!Thesafetyinstructionsinthisoperatinginstructionmanualconcerningthesiteoferectionandtypeoferectionmustalwaysbeobserved!
LUKAS hydraulic units are specially designed to supply LUKAS rescue equipment withhydraulicfluidsothatthisequipmentcanbeusedtorescuevictimsofroad,railorairtrafficaccidentsaswellasfrombuildings.Their use for supplying pressure / fluid to rescue equipment of other manufacturers ispossible,yet requires the technical inspectionandapprovalbyLUKAS ineach individualcase.Theequipmentisnotdesignedtooperatewithouthosesorequipment(operatingtimewithouthosesorequipment<15minutes).
ATTENTION!Whenselectingtheunitstoconnecttotheunit,bearinmindthatthemaximumpossibleuseablevolumeofhydraulicfluidislimited.Thesumofthemax.requiredoperatingvolume(hydraulicfluid)ofallconnectedequipmentmustnotexceedthemaximumpossibleusablevolumeofthepowerunit!
NOTE:AlwaysregisteryourhydraulicunitontheLUKASHydraulikGmbHinternetsite.Thisistheonlywaytoguaranteeyourextendedwarrantycover.Beforeyouusecouplingsfromadifferentcompany,youmustcontactLUKASoranauthoriseddealer.
LUKASP630unitsarenot explosionprotected!Whenusing the equipment in explosion-risk areas youmust make sure thatoperationoftheunitdoesnottriggeranexplosion!TheresponsibilityforexplosionpreventionorforrulingoutworkwiththeP630restswiththeoperatorofthedeviceorwiththepersonresponsibleattheplaceofuse.When working in areas at risk of explosion, all applicable legal, national and international regulations, standards and safety rules for avoiding explosions must be observed without limitation!
The equipment should not come into contact with acids or alkalis. If this isunavoidable,cleantheequipmentimmediatelyafterwardswithasuitablecleaningagent.
10
4. Power unit designation
P 630 S G
Codingforhydraulicpowerunits
Typegroup
Valvevariants
Motorvariants
Valve variants: S = Simultaneousoperation Motor variants: G = Petrolengine
InthecaseofallLUKAShydraulicpowerunits,thehydraulicpumpisoperatedwithamotor.Thepumpconveysthefluidfromthehydraulicoiltankandbuildsupthepressureinthetool.Fluidisdistributedtotheconnectedequipmentthroughcontrolvalves.TheP630SGisapowerunitwithframeandwithapetrolengineandsimultaneousoperation.
5. Functional description 5.1 General information
11
5.2 Installation of the power unit
1 7 5
43
9
10
2
11
12
13
14 15
1 Petroltank 2 Hydraulicfluidtank 3 Enginewithhydraulicpump 4 Connectingblockwith
controlvalves 5 Speedadjustinglever 7 Cable-pullstarter 9 "TURBO"controllever10 Mono-coupling(female)11 Fueltankcap12 Fillercaphydraulicfluid13 Frame14 Rubberbuffer15 Sidepanel16 Airfilter17 Choke18 Fueltap19 ON/OFFswitch(engine
switch)22 Engineoilfillercap/dipstick23 FilllevelindicatorEquipmentback
16
17 18 19
23
22
12
5.3 Motor
WARNING/CAUTION! See also the separate operating instructions of each engine manufacturer
accompanyingthedelivery.
5.3.1 Petrol engineThesehydraulicunitsareequippedwithacombustionenginedrivenbythefuel"petrol".Thepowerunitsareequippedwithacable-pullstarterwithwhichtheengineisstarted.(For specific details, please consult the separate operating instructions of the enginemanufacturer!)
NOTE:TheengineinstalledintheLUKASpowerunitsdoesnotmatcheverydetailoftheenginedescribedinthemanufacturer'sseparateoperatinginstructions.Nevertheless, it is important that you follow all safety rules and operating,maintenance and storage instructions in the separate engine instructions asabsolutesincetheyarenotaffectedbyadjustmentsmadebyLUKAS.
HONDA motors have a main switch that must be activated to switch the power unit on and off.Thespeedadjustingleveronthesepowerunitshastwoswitchpositions.Switch position 1 (standard): Speed 3000 1/min " " and Switch position 2: Speed 3800 1/min " ".
Thesettingisadjustedbymovingthespeedadjustinglever.
13
5.4 ValvesBothvalvesofthepowerunitinthepumpblockarefixedinplace.Thepumpblockisfullyintegrated into the hydraulic power unit. The hose assemblies (pressure line (grey) andreturn(blue))mustbeconnectedtothepumpblock.Therescueequipmentisconnectedtothehoseassemblies.ModelP630unitsareequippedwithaSIMOconnectingblock.
TheconnectingblockoftheP630SGalsohasaTURBOfunction.Witha“TURBO”controllever,eitherbothconnecteddevicescanbesuppliedsimultaneouslywithhydraulicfluid,orasingledevicecanbesuppliedwithdoublethevolume(=TURBOfunction). By supplying at double the feed rate, the speed of the connected device isincreased.
Thehosesareconnectedwiththeconnectingblockviamono-couplings.
5.4.1 Control valve "simultaneous operation" (SIMO)Thisvalveenablestheconnectionoftwopressurehosesandtworeturnhoses.Ithastwoswitching options, each of which controls the pressure application of the pressure hosethatismarkedaccordingly.Thismeansthattwo devices can be supplied with pressure simultaneously and independently of each other.Without impairingtheworkoutput, itenablesworkwithtwodevicessimultaneouslyandindependentlyofeachother.
ATTENTION!When operating several pieces of rescue equipment with one unit, ensurethat theusablevolumeofhydraulicfluid in thepowerunit isgreater than themaximumpossibleoperatingfluidvolumeofallconnectedrescueequipment.
14
TheLUKAShydraulicpowerunitsmodelP630areequippedwithaSIMOconnectingblock.Thepumpisrigidlyconnectedtotheconnectingblock. Double-flowpumpforoperatingwithSIMOvalve
Thepumpusedalwayshastwopressurestagesperpumpfeedflow,onelowpressureandonehighpressure.
Low-pressurelevel(LP) = upto14MPa*
High-pressurelevel(HP)= upto70MPa*
Thechangeoverfromlowpressuretohighpressureiscarriedoutautomaticallybythepump.Thissystemissecuredwithapressurelimitingvalve.Therefore,themaximumpermissiblesystempressurecannotbeexceeded.
5.5 Pumps
*)1MPa=10bar)
5.6 Frame with side sectionsTheP630hydraulicpowerunitismountedwithinaframe.Theframeandsidepanelsarealsoused,despitetherobustdesign,toprotectthepowerunitfromexternalinfluences,suchasforexample,dirtordamage.
5.7 Connection to the rescue equipment
Connectiontotherescueequipmentisviaextensionhosepairsorviahosereels.Theyaresuppliedinvariouslengths.(Forspecificdetails,pleaseconsulttheLUKASrangeofaccessoriesorcontactyourLUKASdealer.)
WARNING/CAUTION!Forsafetyreasons,thepressuresetonthisvalvemustnotbeadjusted(withouttheapprovalofLUKASdirectly)!
15
ATTENTION!Whenconnectingthehoseassemblies/units,alwaysensurethattheconnectioncomponentsarenotdirty.Cleanpriortouseifnecessary!
WARNING/CAUTION! Before connecting the equipment, make sure that all the components used are suitable for the maximum operating pressure of the hydraulic unit! In cases of doubt, you must consult LUKAS directlybeforeconnectingtheequipment!
6. Connecting the hoses / devices
Mono-couplinghalve(male)
Mono-couplinghalve(female)
Dustprotectioncaps
Thehoselines/unitsareconnectedviaquick-disconnectcouplinghalves(femaleandmale)tothehydraulicpumporhosereelinsuchawaythattheycannotbeswappedover.
6.1 Coupling the mono-couplings
0
1
0
16
BA C
C
Remove the dust caps before coupling together. Then push themale and female partstogetherand turn the locking sleeveon the female coupling in thedirection "1" until thelockingsleeveclicks inplace.Theconnectionhasbeenmadeand locked.Decoupling isaccomplishedbyturningthelockingsleeveindirection"0".Couplingofthehoseassemblieswhenunderpressureisalsopossible,assumingthattheconnectedequipmentisnotturnedon.
NOTE:We recommend connecting the coupling halves in a depressurised statewhenworkinginareaswithlowambienttemperatureandusingextensionhoseassemblies/hosereels,asotherwisethecouplingmayrequiretheapplicationofagreatdealofforce.
Fordustprotection,thesupplieddustcapsmustberefitted.
Using the dust protection caps: Thedustprotectioncaps"A"havetwoexternalgrooves"B".Thedustprotectioncapsmustbeinsertedinthefemalecouplinginsuchawaythatthegroovescanbeguidedoverthepins"C".Screwinthedustprotectioncapstothestoptofixinthefemalecouplings.
17
7. Set-up and commissioning
7.1 Set-up
7.2 Commissioning
WARNING/CAUTION!Because of possible spark formation, combustion engine units and electricalequipment cannot be used in an explosion-risk area. Units with combustionenginesmustnotbeusedinenclosedspaces,asthereisadangerofpoisoningand/orasphyxiation!
Theunitistobesetupinasuitablelocation(securelocation/flatsurface/sufficientdistancefromvehicles,loads,sourcesofignition,etc.).LUKASunitsworkperfectlyatanangleofupto20°.However,inordertoguaranteemaximumsafetyandfluidwithdrawal,theyshouldbeoperatedinashorizontalapositionaspossible.
ATTENTION!Nevermixupthefuelandhydraulicfluidtankswhenfillingthetank;thiscandamagethepowerunit!
NOTE:Theengineoil levelmustbeinspectedbeforethefirstcommissioningorafterlongerperiodsofstorage.Firstfilltheengineortopuptheengineoil!Forsafetyreasons,LUKASpowerunitsdonotcontainengineoilupondelivery!
7.2.1 First commissioning-Powerunitwithoutengineoil,hydraulicfluidandpetrol.
1.Pour in the engine oil according to the instructionsin the scope of delivery included with the separatemanufacturer operating instructions regarding the filleropening(engineoilfillercap,seechapter"Installationofthepowerunit").
2.Pourhydraulicoilintothehydraulicfluidtankuntilthefilllevel indicator in the viewingwindow is betweenMIN/MAX (see illustration on the right). The upper markshowstheabsolutefilllevelwhenconnectingadditionalequipmentwithincreasedusablevolume.Theresultingfillquantityisupto3.0l.
3.Pour fuel (petrol) into the tankuntil thefill level is justbelow thefilleropening. If thepowerunit is restingonan inclinedsurface,donotfill the tank to itsmaximumcapacity.
Hydraulic oil filllevelindicator
18
4.Nowbleedthehydraulicpowerunit:
5.Openandremovethetankcapsothatairentersthetank.
6.Opentheventingplugonthepumpblock,tiltthepowerunitbackwardsbyapprox.45°(seeillustration)andwaituntiloilcomesoutfromthebolt.
7.Whenoilcomesoutattheventingplug,theairhasbeenremovedfromthepump.Firstclosetheventingplugandthenreturnthepowerunittothelevel.
8.Checkthefluidlevels.Topupifnecessary.
9.Nowconnect theextensionhosesand/orhose reels (unlessalreadyconnected to theunit)and/orcoupletherescueequipment.
VentingplugPumpblockP 630 SG
19
7.2.3 Commissioning(afterthefirstfillingorpriortouse)
1.Check the fluid level of the engine oil, the hydraulic fluid and the fuel tank.Top up ifnecessary. For precise reading off of the fluid levels and for filling, the hydraulic unitshouldbeaslevelaspossible.
2.Nowconnecttheextensionhosesand/orhosereels(unlessalreadyconnectedtotheunit)and/orcoupletherescueequipment.
Beforestartingthecombustionengine,checkthatthefueltankisfullandthattheengineoilleveliswithinthepermittedtolerances.Ifnecessary,topuptherelevantfluid.
1.Openthepetroltap2.SettheON/OFFswitchtotheONposition.3.MovetheleverfromswitchingpositionAtoswitching
positionB(choke)whenstartingcold4.Pullthecable-starter.5.When themotor is running,switch the leverback to
positionA.
For the detailed procedure for starting the combustionengine,pleaseseetheseparate operating instructions of the engine manufacturer!
BA
8.1 Starting the engine
8. Operation
20
Theenginemustbeswitchedoffforrefuelling!Procedure:1.Openthefueltankcap.2. Fillthetankwithfueluntilthefilllevelisjustbelowthefilleropening.
3.Closethefueltankagainwiththefueltankcap.
WARNING/CAUTION!Besurenottospill fuel. Inparticular,hotenginepartsmustnotcomeintocontactwithfuel;dangeroffireotherwise!Iffuelisspilled,itmustbecleanedupimmediatelywithasuitableabsorbentcloth.Indoingso,becarefulnottoburnyourselfononeofthehotengineparts!Theusedclothmustthenbecleanedordisposedofaccordingtotherelevantprovisionsandguidelines!
8.3 Refuelling
1.SettheON/OFFswitchtotheOFFposition.2.Whentheenginehascometoastandstill,closethe
fueltap.
For more details on switching off the engine, please refer to the separate operatinginstructions of the engine manufacturer!
CAUTION!Nevertouchhotengineparts:thiscouldresultinsevereburns!
8.2 Turning the engine off
21
8.4 Controlling the valves
8.4.1 "Simultaneous operation" control valve (SIMO) P 630 SG
Thepumpblockalsohasa“TURBO”controllever,allowingthe user to switch to the “TURBO” function (see diagramabove).Withthisfunction,theswitchpositionofthe“TURBO”controllevercanbeusedtosupplyoneofthetwoconnectionswithdoublethevolume.The"TURBO"functionisactivatedbyturningthe“TURBO”controllevertowardstheconnectionthatistobepressurisedatthedoubledpumpingoutput.
NOTE:The“TURBO”controllevermustalwaysbemovedcompletelyuptothestop.
22
9. Dismantling the equipment / deactivation following operation
WARNING for power units with combustion engines!Checkthattheengineswitchissettothe“OFF“positionandremainstheretopreventtheunwantedstartingofthepowerunit!
Oncetheworkhasbeencompleted,allconnectedequipment is tobereset to itsneutralposition(storageposition)beforetheunitisshutdown.Youcanthenswitchofftheengineofthepowerunit.
Mono-couplings:If the connected hose assemblies are to be dismantled during shut-down, decouple asdescribedinchapter"Couplingthemono-couplings".Ensurethatyouputthedustprotectioncapsbackontothemono-couplinghalves.
Cleanthehydraulicpowerunitofanystubborndirtpriortostorage.
If theequipment is tobestored fora longerperiodof time, theexterior is tobecleanedcompletely and themechanicallymobile parts are to be lubricated. If storing a unitwithcombustionengine,youshouldalsoremovethefuelfromthefueltank.Avoidstoringthehydraulicpowerunitsinadampenvironment.Observe the additional regulations in the separate operating instructions for the hoses.
CAUTION!Depending on the size and weight of the hydraulic power unit it should betransportedtothestoragelocationbyoneormorepersons.
23
10. TestsThe hydraulic power units are subject to very high levels ofmechanical stress.A visualinspectionmustthereforebecarriedoutaftereveryuseandatleastonevisualinspectionmustbecarriedouteverysixmonths.This reveals wear and tear in good time; punctual replacement of these wearing partspreventsdamageto theequipment.Alsocheckregularly thatall thesecuringscrewsaretightened(ifapplicable,complywithprescribedtighteningtorques)Every3yearsorwhentheremightbedoubtsregardingthesafetyorreliabilityoftheunit,anadditionalfunctioncheckistobecarriedout(inthisconnection,complywiththeapplicablenational and international regulationswith regard to themaintenance intervals of rescueequipment).Operating time per day In the Federal Republic ofGermany, regular safetyinspections according to the regulations of the Gesetzlichen Unfallversicherung (GUV;connoted‘Legalaccidentinsurance’)aremandatory.
ATTENTION!Cleanoffanydirtbeforecheckingtheequipment!
WARNING/CAUTION!To perform inspections,maintenance and repairs, personal safety equipmentappropriatefortheworkisanabsoluterequirement.(whennecessaryalsousescreens).
LUKASoffersasuitabletestkitforthefunctiontestofthehydraulicunits.(Forspecificdetails,pleaseconsulttheLUKASrangeofaccessoriesorcontactyourLUKASdealer.)
10.1 Recommended test intervals10.1.1 General visual inspection
Avisualinspectionmustbecarriedoutaftereveryuse,butatleastonceeverysixmonths.
24
Visual Inspection
• Tightnessofallhydraulicconnections,• Generaltightness,noleakage(sweatedoilsdonothaveanyinfluenceonthefunction),• isthereanydetectabledamagetotheengine,connectingblocks,ontheframeortheside
sections,• Isthereanysignofdamagetothehydraulicsorfueltank,• Sideplatespresentandtightened,• Presenceand legibility of the identificationplate, all actuation signs, instruction signs,
markingsandwarnings,• Thepresenceandperfectconditionofallcovers(e.g.exhaustdeflector),• Allfluidlevelsarewithinthespecifiedtolerances,• Aretherotaryswitchesandswitchingleversinproperworkingorderandundamaged,• Couplingsmustbeeasytocouple,• Dustprotectioncapsmustbeavailable,• Allrequiredaccessoryparts(e.g.sparkingplug,sparkingplugspannerandfuelcan)are
present.• Checkforleaks.
Functional test• Unconventionalornoticeablenoisesheardduringoperation• Cable-pullstarterfullyfunctional,• Engineswitchfullyfunctional,• Testformaximumload.
10.2 Visual and function check
Operating time per day Functional test
upto1hour 1xannually
upto8hours 1xperquarter
upto24hours 1xpermonth
In addition to these test intervals you need to carry out a function test if: - theunitmakessuspiciousnoises, - thereisajustifiedsuspicionofinternaldamagetotheunit.
Ifthenoisesandsuspicionsreferredtoaboveariseseveraltimesinamonth,orifmaximumpressurecannotbeachievedduringthefunctiontest,youneedtocontactLUKAScustomerservice immediately. The contact details are given in the Chapter "Fault analysis".
10.1.2 Function check
NOTE:usetheLUKAStestkit,includingtestinginstructions,forthefunctiontest.
25
11.1 General informationLUKAShydraulicunitsmodelP630requireonlylimitedmaintenance.Forservice work, specialtrainingisunnecessary;however,knowledgeofthefunctionofthepowerunit,thelegalsafetyinstructionsanddealingwiththerequiredtoolsarebasicprerequisites.
ATTENTION!Neveruseunnecessaryforceduringmaintenanceworkthatcoulddamagethecomponentsofthepowerunitorcompromiseoperationalsafety.
Duetothecomplexinstallation,service workonthehydraulicpowerunitmustonlybeexecutedbytheequipmentmanufacturer,personneltrainedbytheequipmentmanufacturer,orauthorisedLUKASdealers.
WARNING/CAUTION!Protective clothes must be worn when maintenance and repairs are beingcarriedout,sincethedevicesmayalsobepressurisedwhennotinoperation.
Duringwork,ensurethatallcomponentsareparticularlyclean,sincedirtcandamagetherescueequipment!
11. Maintenance and repair
26
ATTENTION!Since LUKAS hydraulic units are designed for top performance, only thosecomponentsinthereplacementpartslistsfortherelevantunitcanbereplaced.Anyothercomponentsintheunitmayonlybereplacedif:- YouhaveparticipatedinanappropriateLUKASservicetrainingcourse.- YouhavetheexpresspermissionofLUKAScustomerservice(uponrequest,
wewillcheckforthegrantofpermission.Examinationineachindividualcasenecessary!)
Whencleaningunitsandequipment,notethatnocleaningagentmaybeusedthathasapHvalueoutsidetherange5-8!
ATTENTION!Attentionmustbepaidtoensuringthatnooperatingfluidscanescapefromunitswithcombustionenginesduringrepairwork!
11.2 Service work on the hydraulic unit
11.2.1 Care instructionsTheexteriorofthedevicemustbecleanedfromtimetotime(not the electrical contacts) andthemetallicsurfaces(not the electrical contacts)mustbetreatedwithasuitableagenttoprotectagainstcorrosion.(Incaseofdoubt,contactyourauthorisedLUKASdealerorLUKASdirectly!)
11.2.2 Function and load test Ifthereisanydoubtregardingthesafetyorreliabilityoftheequipment,afunctionandstresstestmustalsobeperformed.LUKASoffersappropriatetestingequipmentforthis.
11.2.3 Replacing the hydraulic fluid- Afterapprox.200deployments,butafterthreeyearsatthelatest,replacethehydraulic
fluid.- Thefluidshouldbereplacedafterithaswarmedup.- Theenginemustbeswitchedoff!- Theusedhydraulicfluidmustbedisposedofproperly.
27
A
B
5. Pourthenewhydraulicfluidthroughthefillerneckintothehydraulictankandclosetheneckagainwithfillercap"B".
6. TheunitthenhastobebledagainasdescribedintheChapter"Commissioning".
Replacing the hydraulic fluid - procedure:1. Placethepowerunitonaslightlyelevatedbasesothatthedrainplugforthehydraulic
fluidcanbeeasilyreached.2. Placeasuitablecollectioncontainerunderthe"A"drainplug.3. Openthe"B"fillercap,removethe"A"drainplugandletthehydraulicfluidrunintothe
providedcollectioncontainer.4. Screwthe"A"drainpluginagain(tighteningtorquemax.5Nm).
11.2.4 Changing decalsAlldamagedand/orillegibledecals(safetynotices,typeplateetc.)mustbereplaced.
Procedure:1.Removedamagedand/orillegibledecals.2.Cleansurfaceswithindustrialalcohol.3. Affixnewdecals.
Takecaretoaffixthedecalsinthecorrectpositions.Ifthisisnolongerknown,youshouldaskyourauthorisedLUKASdealerorcontactLUKASdirectly.
28
NOTE:Non-observanceofthemaintenanceplancanleadtomalfunctionsthatarenotcoveredbythewarranty.
Fordismantlingthesparkingplug,useacommercially-availablesparkingplugspannerwithuniversaljointandspannersizeof16mm(5/8inch).Astraight/rigidsparkingplugspannerwoulddamageorbreakoffthesparkingplug!
(also observe the separate instructions from the engine manufacturer)
First month or after the first 20 hours (first time):• Replaceengineoil(seeoperatinginstructionsoftheenginemanufacturer).
You must conduct the following service measures every 50 operating hours:• Cleantheairfilterelement.• Afterusinginadustyenvironment,inspecttheairfilterelementandcleanimmediately,
ifnecessary.
You must conduct the following service measures every 100 operating hours:• Replaceengineoil.• Checkthesparkingplug,cleanifnecessary/settheelectrodegapofthesparkingplug
You must conduct the following service measures every 200 operating hours:• Replacethesparkingplug• Replaceairfilter
(Thefollowingserviceworkshouldbeexecutedbyanauthoriseddealer,LUKASdirectlyorthe engine manufacturer.)
You must conduct the following service measures every 300 operating hours:• Replacethesparkingplugandthefilterelement• Cleanandadjustthecarburettor,valveclearance,valveseatandcylinderhead.
You must conduct the following service measures every 1000 operating hours or every 2 years:
• Checkthestarter• Inspecttheenginefordamage• Checkthefuellineandreplace,ifnecessary.
11.3 Additional service work
29
11.3.1 Replacing and cleaning the air filter
Procedure:Ifpresent,removetherearsidepanelofthehydraulicpowerunit,inthatthefixingclipandthesidepanelareremoved.1.Unscrewbothboltsfromtheairfiltercoverandremovethecover.2.Removethefoamairfilterinsertfromthecover.3.Takethepaperairfilterinsertfromtheairfilterhousing.4.Checkbothairfilterinsertsandreplaceifdamaged.Thepaperairfilterinsertmustalways
bereplacedatplannedintervals.5.Cleantheairfilterinsertsifreusingthem. Paperairfilterinsert:Tapoutthepaperairfilterinsertafewtimesonahardsurfaceto
removedirtorblowcompressedair[notmorethan207kPa(2.1kg/cm)]fromtheairfilterhousingsidethroughthefilterinsert.Neverattempttobrushoutdirtbecauseitwouldbepressedinbythebristles.Replacethepaperairfilterinsertifitisexceedinglydirty.
Foam air filter insert: Clean in warm soapy water, rinse and allow to dry thoroughly. Orcleaninnon-flammablesolventandletdry.Donotintroduceanyoiltothefoamairfilterinsert.
6.Wipeawaydirtfromtheinsideoftheairfilterhousingwithadampcloth.Ensurethatdirtdoesnotpenetratetheairductleadingtothecarburettor.
7.Thenre-fitthefilter.
NOTE:Keepingtheairfilteringoodconditionisextremelyimportant.Penetratingdirtleadstodamageandwearintheengineincaseofincorrectinstallation,incorrectdamageorunsuitablefilterinserts. Alwayskeeptheairfilterinsertclean.
AirfiltercoverBolts
Foamairfilterinsert:
Paperairfilterinsert:
Airfilterhousing
30
11.3.2 Replacing, cleaning and setting the sparking plug
Procedure:Inordertodelivergoodperformance,thesparkingplugmusthaveacorrectelectrodegapandbefreefromdeposits.1.Detachthesparkingplugconnectorandremoveanydirtnearthesparkingplug.2.Unscrewthesparkingplugusinga16mm(5/8inch)sparkingplugspanner.3.Checkthesparkingplug.Replacethesparkingplugifitisdamaged,extremelydirty,the
sealingwasherisinpoorconditionortheelectrodesareworn.4.Measure theelectrodegapon thesparkingplugwithawire feelergauge.Correct the
electrodegap,ifrequired,bycarefullybendingthesideelectrode.Targetelectrodegap:0.6-0.7mm(0.024-0.028in)
5.Carefullyscrewinthesparkingplugbyhandinordertoavoidstrippingthethread.6.Tightenthesparkingplugaftermountingwitha5/8-inchsparkingplugspannerinorderto
compressthewasher.7.Anewsparkingplugshouldbetightenedbyanadditional1/2turnafterfittinginorderto
compressthewasher.8.Ausedsparkingplugshouldbetightenedbyanadditional1/8to1/4turnafterfittingin
ordertocompressthewasher.9.Placethesparkingplugconnectoronthesparkingplug.
NOTE: Aloosesparkingplugcanoverheatanddamagetheengine.Asparkingplugthatistootightcandamagethethreadinthecylinderhead.
0.6-0.7mm(0.024-0.028in)
Gasket
Sideelectrode
11.3.3 Replacing the engine oil and the engine oil filter
Fortheprocedureforreplacingtheengineoilandengineoilfilter,pleaserefertotheseparateoperatinginstructionsoftheenginemanufacturer!
Sparkingplugspanner
Sparkingplugcon-nector
31
11.3.4 Mono-couplingsThemono-couplingsmustbereplacedif:- thereisexternaldamage,- thelockingdoesnotfunction,- hydraulicfluidcontinuestoleakinthecoupled/uncoupledstate.
WARNING/CAUTION!Neverrepaircouplings:theymustbereplacedbygenuineLUKASparts!
Procedure for coupling to valve block:
1. Firstemptythehydraulictankasdescribedinthechapter"Replacingthehydraulicfluid".2.Removescrewedfittingsonthecoupling.3.Removecouplingsandunderlyingseals4.Positionthenewcoupling,togetherwiththeseals,ontothevalveblock.5.Re-attachthecouplingswiththeboltsandtightentoatorqueofMA=40Nm.6. Thehydraulicfluidtankmustberefilledandthepowerunitvented.
3. Loosentheunionnutsonthehoselinesandremovethecoupling.
Procedure for coupling to hose pairs:
1. Firstemptythehydraulictankasdescribedinthechapter"Replacingthehydraulicfluid".2. Pullthekink-protectionbackfromthecouplings.
32
11.3.5 Quick-disconnect couplings
Thequick-disconnectcouplingsmustbereplacedif:- thereisexternaldamage,- thelockingdoesnotfunction,- hydraulicfluidcontinuestoleakinthecoupled/uncoupledstate.
WARNING/CAUTION!Neverrepaircouplings:theymustbereplacedbygenuineLUKASparts!
DuringassemblytightentheunionnutsonthehoselinetoatorqueofMA=35Nm.
Procedure:
1. Loosentheunionnutsonthehoselineandremovethecoupling.2.Positionthenewcouplingandtightentheunionnutonthehoseassembliestoatorqueof
MA=35Nm.
ATTENTION!Thereturnhose,whichisscrewedontotheport“T”oftherescuetool,mustbeequippedwithaquick-disconnect-coupling(male)always.However, the supply hose line must be equipped with a quick-disconnect-coupling(female).
ATTENTION!Ensurethatconnection“T1”/"T2"onthepumpblockisalwaysconnectedtoconnection“T”onthemono-coupling.
4.PositionthenewcouplingandtightentheunionnutsonthehoseassembliestoatorqueofMA=40Nmandpushthekink-protectionofthecouplingsback.
5. Thehydraulicfluidtankmustberefilledandthepowerunitvented.
33
NOTE: Incaseoffaultswhichdirectlyaffectthecombustionengine,pleasealsoobservetheseparateinstructionsintheoperatinginstructionsoftheenginemanufacturer.
Fault Check Cause SolutionCombustionenginewillnotstart
Checkfuellevelintank
Fueltankempty Topupfuel
Checkfuelline Faultinthefuelline Shutdownimmediatelyandhaverepairedbyauthoriseddealer,motor/enginemanufacturerordirectlybyLUKAS
Inspectengineswitch
Cable-pullstarter Activatecable-pullstarter
MotorswitchnotsettoChoke
SetmotorswitchtoChoke
Hydraulicunitorenginenotsuitablefortheworkingenvironment
Ambienttemperaturetoolow
Forthesolution,consulttheseparateoperatinginstructionsoftheenginemanufacturer.Useadifferenthydraulicfluidoroperatingfluidthatissuitablefortherelevantambienttemperature(seeChapterI"TechnicalData")
Notenoughoxygenintheairbecauseofthealtitudeofapplicationlocationofthehydraulicmotor
Useadifferentmoresuitablehydraulicunit.
Havetheenginesettothealtitudeofapplicationofthehydraulicpowerunitbyanauthoriseddealer,enginemanufacturerorLUKASdirectly(onlyiftheunitistobeusedfrequentlyatthisaltitude).
Checkairfilter Airfiltercontaminated Cleanorreplacetheairfilter.
Areallvalvessettopressure-free(restsetting)?
Combustionmotordefectiveoroverloadedduetodifferentdefectintheunit
Haverepairedbyauthoriseddealer,motor/enginemanufacturerordirectlybyLUKAS
12. Fault analysis
34
Fault Check Cause SolutionThemotorisrunning,buttheconnectedrescueequipmentisnotmoving/movingveryslowlyuponactivationofthevalve.
Checkhose Hoseassemblynotconnectedproperlyorisdamaged
Checkconnectionofhoseandreconnectifnecessary.
Checktheswitchpositionofthevalveleveronthepumpblockofthehydraulicunit
Valvenotswitchedtosupplylinepressurisation.
Switchvalvetopressureloadofthesupplyline.
Defectivepumpunit HaverepairedbyauthoriseddealerordirectlybyLUKAS
Connectadifferentunitandcheckwhetheritworkswhenactuated
Thepreviouslyconnectedunitisdefective.
Rectificationseeoperatinginstructionsoftheconnectedunit
Mono-coupling(female)defective
Replacemono-coupling(female)
Theconnectedrescueequipmentdoesnotmoveonactivationofthevalve,ormovesonlyveryslowlyorunevenly.
Connectadifferentunitandcheckwhetheritworkswhenactuated
Thepreviouslyconnectedunitisdefective.
Rectificationseeoperatinginstructionsoftheconnectedunit
Checktheswitchingpositionofthe“TURBO”controlleveronthepumpblockofthehydraulicsystem.
The“TURBO”controlleverisnotfullyswitched.
Checktheswitchingpositionofthe"TURBO"controlleverandreswitchifnecessary(toendposition).
Defectivepumpunit HaverepairedbyauthoriseddealerordirectlybyLUKAS
Airinhydraulicsystem Ventthehydraulicsystem
Plug-incoupling(female)defective
Replaceplug-incoupling(female)
Mono-coupling(female)defective
Replacemono-coupling(female)
35
Fault Check Cause SolutionConnectedrescuedevicedoesnotreachitsfinalposition
Checkhydraulicfluidvolumeinhydraulictank
Insufficientfluidinthehydraulictank
TopuphydraulicfluidtothemaximumfillinglevelCaution! Before topping up the rescue equipment, return to the base position!
Usablehydraulicfluidvolumeoftheunitisinsufficient
Useadifferentrescuedevicewithademandquantitybelowthemaximumusablequantityoftheunit
Connectedrescuedevicedoesnotreachitsspecificperformancedata
Maximumpermittedoperatingpressureofthepumpisnotreached
HavethepressurelimitingvalveresetorrepairedbyauthoriseddealerordirectlybyLUKAS
Pumpblockdefective HaverepairedbyauthoriseddealerordirectlybyLUKAS
Connectedunitdefective
Rectificationseeoperatinginstructionsoftheconnectedunit
Duringfunctiontest:Apressuregaugeinstalledbetweentherescueequipmentandthehydraulicpowerunitdoesnotindicatethemaximumoperatingpressureoftheequipment.
Checkthedetailsoftherescuedevice
Theoperatingpressureoftheconnectedrescuedeviceislockedinternally
Norepairorfaultrectificationrequired
Connectedrescuedeviceisdefective
Consulttheseparateoperatingmanualfortheconnectedrescuedevice
Hydraulicunitdefective HaverepairedbyauthoriseddealerordirectlybyLUKAS
36
Fault Check Cause SolutionFluidcomingoutfromhydraulicfluidtank
Connectedunitnotinbasepositionyetandfluidcomingoutoffillercap?
Returnofthehydraulicfluidfromtherescuedeviceexceedsthetank’smaximumquantitywhenfilled.
Reducefluidlevelinthehydraulictankto“Minimum”mark,movetheunittothebasepositionandthenfillbackupwithhydraulicfluidtothe“Maximum”level
Fluidleaksfromadifferentlocation?
Leakfromtank,linesorseals
ReplacedefectivecomponentsorrepairbyauthoriseddealerorLukasdirectly
Leakingfluidbetweenengineandflangebearing
Radialshaftsealonthedriveshaftisdefective
HaverepairedbyauthoriseddealerordirectlybyLUKAS
Hydraulicfluidmilkyandcloudy
Water/condensationinthesystem
Replacethehydraulicfluidimmediately
Hosescannotbecoupled
Couplingdefective Couplingmustbereplacedimmediately
37
Fault Check Cause SolutionItisfrequentlynotpossibletocouplehoseassemblies
Hydraulicfluidnotadaptedtotheapplicationsituation
Hydraulicfluidmustbereplaced(seechapter"Recommendedhydraulicfluids")
Couplingdefective Couplingmustbereplacedimmediately
Leakinthecouplings Couplingdefective Couplingmustbereplacedimmediately
Leakageatthedriveshaftofthehydraulicpump
Shaftsealdefective. Repairbyanauthoriseddealer,bypersonnelspeciallytrainedbyLUKAS,orbyLUKASitself
ContactanauthorisedLUKASdealerortheLUKASCustomerServiceDepartmentdirectlyifthemalfunctionscannotberectified.TheaddressfortheLUKASCustomerServicedepartmentis:
LUKAS Hydraulik GmbHA Unit of IDEX Corporation
Weinstraße39, D-91058ErlangenTel.: (+49)09131/698-348Fax.: (+49)09131/698-353
NOTE: Incaseoffaultswhichaffectthecombustionengine,pleasealsoobservetheinstructionsintheseparateoperatinginstructionsoftheenginemanufacturer.
38
13. Technical data
NOTE:The following tables contain only the technical data required for standardacceptance.AdditionaldataconcerningyourunitcanbeobtainedfromLUKASonrequest.The limitation of themax. fill quantity of the hydraulic tank results from the"operabilityatanincline"prescribedinthestandards.
Becauseallvaluesaresubjecttotolerances,theremaybesmalldifferencesbetweenthedataforyourdeviceandthedatainthefollowingtables!The values may also differ because of reading inaccuracies and/or tolerances in themeasuringequipmentused.
13.1 Power Unit13.1.1 Basic dimensions of the power unit (mm [inch])
Power unit P 630 SG:
39
1) HD = Highpressure 2) ND=Lowpressure 3) 1MPa=10bar
13.1.2 Technical data P 630 SG
Device type P 630 SGArticle number 81-53-20
Motor type 4-strokepetrolengine
Engine power rating[kW] 1,8/2,2[HP] 2.4 / 3.0
Engine speed[min-1]
3000/3800[rpm.]
Feed rate simultaneous (HD)1)
[l/min] 2x0,55/2x0,7[gal.-US/min] 2x0.15/2x0.19
Feed rate turbo (HD)1)
[l/min] 1x1,1/1x1,35[gal.-US/min] 1x0.29/1x0.36
Feed rate simultaneous (ND)2)
[l/min] 2x2,4/2x3,0[gal.-US/min] 2x0.63/2x0.79
Feed rate turbo (ND)2)
[l/min] 1x4,7/1x5,8[gal.-US/min] 1x1.24/1x1.53
Max. operating pressure (HD)1)
[MPa]3) 70[psi.] 10000
Max. operating pressure (ND)2)
[MPa]3) 14[psi.] 2000
Max. fill volume hydraulicfluid
[l] 2,2[gal.-US] 0.58
Max. fill volume Petrol
[l] 0,77[gal.-US] 0.17
Weight (with petrol and hydraulic fluid)
[kg] 23,9
[lbs.] 56.7
Valve variants SimultaneousoperationMax. unit connection facilities 2
40
13.2 Noise emissions (Sound pressure level)
Device type P 630 SGSpeed 3000[1/min]/[rpm] 3800[1/min]/[rpm]Idle run(accordingtoEN) [dB(A)] 80 84
Full load(accordingtoEN) [dB(A)] 84 88
Idle run(accordingtoNFPA) [dB(A)] 73 77
Full load(accordingtoNFPA) [dB(A)] 77 80
Explanation of dual number noise emission values according to DIN EN 13204:2012-09Serialnumberofthemachine,operatingconditionsandothercharacteristicproperties:Model...P630SG,type...81-53-20,maximumworkingpressure...700bar,enginespeed....3800[1/min]/[rpm]INDICATEDDUALNUMBERNOISEEMISSIONVALUESaccordingtoENISO4871MeasuredA-ratedemissionsoundpressurelevelLpA,indB,referredto20μPa....88Measurementuncertainty,KpA,indB.....4MeasuredA-ratedemissionsoundpowerlevel(ifrequired)LWA,indB,referredto1pW....101Measurementuncertainty,KpA,indB.....4ValuesdeterminedaccordingtoEN13204,AppendixB,usingbasicstandards ENISO3744andENISO11201.NOTE!Thesumofthemeasurednoiseemissionvaluesandtheassociatedmeasure-mentuncertaintythatcanoccurduringthemeasurementrepresenttheupperlimitofthemeasuredvalues.
41
13.3 Sparking plug
13.5 Fuel
Sparking plug type: CR5HSB(NGK) U16FSR-UB(DENSO)
Fuel: Lead-freepetrol ROZ91toROZ98
13.4 Sparking plug spanner
Universal joint sparking plug spanner with spanner size 16 mm (5/8 inch)
42
13.7 Hydraulic fluid recommendation
13.8 Operating and storage temperature range
MineraloilDINISO6743-4forLUKAShydraulicequipmentandothers
Oiltemperaturerange Oildesignation Viscosityrating RemarksA -20....+55°C HM10 VG10
Oiltemperaturerange Oildesignation Viscosityrating RemarksA -4.0 .... +131°F HM10 VG10
recommendedrangeofviscosity:10...200mm²/s(10…200 cSt.)SuppliedwithHM10DINISO6743-4.
ATTENTION!Beforeyouusehydraulicfluidsfromadifferentmanufacturer,youmustcontactLUKASoranauthoriseddealer.
Operating temperature [°C]/[°F] -20 … +55 -4 … +131
Ambient temperature (deviceinoperation) [°C]/[°F] -25 … +45 -13 … +113
Storage temperature (devicenotinoperation) [°C]/[°F] -30 … +60 -22 … +140
13.6 Engine oil
43
14. EC Declaration of Conformity
LUKAS Hydraulik GmbHA Unit of IDEX Corporation
Weinstraße 39, D-91058 ErlangenTel.: (+49) 0 91 31 / 698 - 0Fax.: (+49) 0 91 31 / 698 - 394e-mail: [email protected]
Made in GERMANY
© Copyright 2017 LUKAS Hydraulik GmbHP630SG_manual_175070085_en.indd
Subj
ect t
o ch
ange
s
Please dispose of all packaging materials and removed items properly.
WARNING/CAUTION! Beforeconnectingtheequipment,makesurethatall the components used are suitable for the
maximum operating pressure of the hydraulic unit!Incasesofdoubt,you must consult LUKAS
directlybeforeconnectingtheequipment!