9
235 NE 23rd STREET LINCOLN BLVD LINCOLN BLVD HODGE BLDG CONNORS BLDG THORPE BLDG WILL ROGERS BLDG ODOT CAPITOL BLDG NE 21st STREET NE 28rd STREET N LINDSAY AVE OKLAHOMA STATE BANKING CONCOURSE THEATER SEQUOYAH BUILDING ATTORNEY GEN. BLDG NE 18th STREET WALNUT AVE DENVER DAVISON BLDG Oklahoma City, OK Project Information: Project Location: Oklahoma City, OK Using Agency: CAP Project Number: 20367 Issue Date: CAP PROJECT NUMBER: 20367 OMES Concourse Theater Audio/Visual Upgrades VOLUME 1 OF 1 Approvals: State Fire Marshal Department of Environmental Quality Water Resources Board Architect Of Record: GH2 ARCHITECTS, LLC 320 S. BOSTON AVE. SUITE 100 TULSA, OK 74103 918-587-6158 WWW.GH2.COM Date Mickerl Jones Director This approval is for compliance with State Statute 61 O.S. 204 A. 2 only. This review and approval shall not be considered a comprehensive review or a quality control check of the Contract Documents. The Consultant shall be solely responsible for any and all errors, omissions or conflicting information in the Contract Documents. Sheet: Of Cover Sheet G001 9 STATE OF OKLAHOMA Office of Management & Enterprise Services, Capital Assets Management, Construction & Properties Copyright © 2021 State of Oklahoma, Office of Management and Enterprise Services, Capital Asset Management, Construction and Properties. The documents contained herein are protected by the United States copyright laws and may not be reproduced, distributed, sold transmitted, displayed, published or broadcast without prior written consent of the State of Oklahoma, Construction and Properties. G001 GENERAL ARCHITECTURAL A101 Project Name: OMES Concourse Theater AV OMES Concourse Theater Audio/Visual Upgrades FLOOR PLAN & DETAILS COVER SHEET, SHEET INDEX, AND VICINITY MAP Engineer Of Record: The Americans with Disabilities Act of 1990 (2010 ADA Standards for Accessible Design) A. APPLICABLE CODES AND STANDARDS (www.ok.gov/oubcc/) 2015 International Building Code (as modified by State of Oklahoma) 2015 International Plumbing Code (as modified by State of Oklahoma) 2015 International Mechanical Code (as modified by State of Oklahoma) 2015 International Fire Code (as modified by State of Oklahoma) 2015 International Fuel Gas Code (as modified by State of Oklahoma) 2015 International Residential Code (as modified by State of Oklahoma) 2015 International Existing Building Code (as modified by State of Oklahoma) 2014 National Electric Code (as modified by State of Oklahoma) CRUX TECHNOLOGY 2448 E. 81ST ST. SUITE 4817 TULSA, OK 74137 800-685-6440 TG 101 GENERAL NOTES, SYMBOLS & RESPONSIBILITY SCHEDULE T 101 FLOOR PLAN RCP T 102 FLOOR PLAN RCP - ALTERNATE AUDIO VISUAL T 103 VIDEO WALL PROJECTION SCREEN T 104 PLATE DETAILS T 105 FRONT END FUNCTIONAL T 106 BACK END FUNCTIONAL

OMES Concourse Theater

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

235

NE 23rd STREET

LIN

CO

LN

B

LV

D

LIN

CO

LN

B

LV

D

HODGE BLDG

CONNORS BLDG

THORPE BLDG

WILL ROGERS BLDG

ODOT

CAPITOL BLDGNE 21st STREET

NE 28rd STREET

N L

IN

DS

AY

A

VE

OKLAHOMA STATE BANKING

CONCOURSE THEATER

SEQUOYAH BUILDING

ATTORNEY GEN. BLDG

NE 18th STREET

WA

LN

UT

A

VE

DENVER DAVISON BLDG

Oklahoma City, OK

Project Information:

Project Location: Oklahoma City, OK

Using Agency:

CAP Project Number: 20367

Issue Date:

CA

P P

RO

JE

CT

N

UM

BE

R: 2

03

67

O

ME

S C

on

co

urs

e T

he

ate

r A

ud

io

/V

is

ua

l U

pg

ra

de

sV

OL

UM

E 1

O

F 1

Approvals:

State Fire Marshal

Department of Environmental Quality

Water Resources Board

Architect Of Record:

GH2 ARCHITECTS, LLC

320 S. BOSTON AVE.

SUITE 100

TULSA, OK 74103

918-587-6158

WWW.GH2.COM

DateMickerl Jones

Director

This approval is for compliance with State

Statute 61 O.S. 204 A. 2 only. This review and

approval shall not be considered a

comprehensive review or a quality control check

of the Contract Documents. The Consultant

shall be solely responsible for any and all errors,

omissions or conflicting information in the

Contract Documents.

Sheet: Of

Cover Sheet

G001 9

STATE OF OKLAHOMA

Office of Management

& Enterprise Services,

Capital Assets Management,

Construction & Properties

Copyright © 2021 State of Oklahoma, Office of Management

and Enterprise Services, Capital Asset Management,

Construction and Properties. The documents contained

herein are protected by the United States copyright laws and

may not be reproduced, distributed, sold transmitted,

displayed, published or broadcast without prior written

consent of the State of Oklahoma, Construction and

Properties.

G001

GENERAL

ARCHITECTURAL

A101

Project Name: OMES Concourse

Theater AV

OMES Concourse Theater

Audio/Visual Upgrades

FLOOR PLAN & DETAILS

COVER SHEET, SHEET INDEX, AND VICINITY

MAP

Engineer Of Record:

The Americans with Disabilities Act of 1990 (2010 ADA Standards for Accessible Design)

A.

APPLICABLE CODES AND STANDARDS (www.ok.gov/oubcc/)

2015 International Building Code (as modified by State of Oklahoma)

2015 International Plumbing Code (as modified by State of Oklahoma)

2015 International Mechanical Code (as modified by State of Oklahoma)

2015 International Fire Code (as modified by State of Oklahoma)

2015 International Fuel Gas Code (as modified by State of Oklahoma)

2015 International Residential Code (as modified by State of Oklahoma)

2015 International Existing Building Code (as modified by State of Oklahoma)

2014 National Electric Code (as modified by State of Oklahoma)

CRUX TECHNOLOGY

2448 E. 81ST ST.

SUITE 4817

TULSA, OK 74137

800-685-6440

TG 101 GENERAL NOTES, SYMBOLS &

RESPONSIBILITY SCHEDULE

T 101 FLOOR PLAN RCP

T 102 FLOOR PLAN RCP - ALTERNATE

AUDIO VISUAL

T 103 VIDEO WALL PROJECTION SCREEN

T 104 PLATE DETAILS

T 105 FRONT END FUNCTIONAL

T 106 BACK END FUNCTIONAL

AutoCAD SHX Text
PROJECT GENERAL NOTES
AutoCAD SHX Text
1. CONTRACTOR SHALL VISIT THE EXISTING FACILITY TO DETERMINE THE EXTENT CONTRACTOR SHALL VISIT THE EXISTING FACILITY TO DETERMINE THE EXTENT AND NATURE OF THE WORK AND THE CONDITIONS WITHIN WHICH THE WORK MUST BE ACCOMPLISHED. SUBMISSION OF A BID WILL CONSTITUTE ACCEPTANCE OF EXISTING CONDITIONS. 2. PROTECT EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN INCLUDING BUT PROTECT EXISTING CONSTRUCTION AND EQUIPMENT TO REMAIN INCLUDING BUT NOT LIMITED TO EXISTING SURFACES AND / OR MATERIALS. 3. ALL NEW BUILDING MATERIALS AND PRODUCTS SHALL NOT CONTAIN ASBESTOS. ALL NEW BUILDING MATERIALS AND PRODUCTS SHALL NOT CONTAIN ASBESTOS. 4. PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION REQUIRED TO PROVIDE TEMPORARY BARRICADES AND OTHER PROTECTION REQUIRED TO PREVENT INJURY TO PEOPLE AND DAMAGE TO ADJACENT ITEMS TO REMAIN. 5. PRIOR TO ANY WORK ON SITE, COORDINATE ALL ACTIVITY AND SCHEDULES WITH PRIOR TO ANY WORK ON SITE, COORDINATE ALL ACTIVITY AND SCHEDULES WITH THE OWNER. 6. NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE EXISTING NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE CONSTRUCTION DOCUMENTS. 7. COORDINATE ALL DEMOLITION WORK WITH NEW CONSTRUCTION PRIOR TO START. COORDINATE ALL DEMOLITION WORK WITH NEW CONSTRUCTION PRIOR TO START. 8. CAREFULLY REMOVE ITEMS IDENTIFIED AS SALVAGED, SCHEDULED FOR RE-USE CAREFULLY REMOVE ITEMS IDENTIFIED AS SALVAGED, SCHEDULED FOR RE-USE OR RELOCATION. STORE IN PROTECTED AREA UNTIL REINSTALLATION IS ACHIEVED. REPAIR DAMAGE CAUSED BY CARELESS REMOVAL OR IMPROPER STORAGE OR REPLACE SUCH ITEMS TO OWNER'S SATISFACTION. 9. CONTACT ARCHITECT BEFORE REMOVING OR DEMOLISHING ANY EXISTING CONTACT ARCHITECT BEFORE REMOVING OR DEMOLISHING ANY EXISTING CONSTRUCTION OR ITEMS NOT SHOWN TO BE REMOVED. STRUCTURAL MEMBERS SHALL NOT BE CUT OR ALTERED, EXCEPT AS SHOWN, WITHOUT AUTHORIZATION FROM THE ARCHITECT. 10. CARE SHALL BE TAKEN TO LOCATE AND PROTECT ANY STRUCTURAL CARE SHALL BE TAKEN TO LOCATE AND PROTECT ANY STRUCTURAL COMPONENTS THAT ARE WITHIN WALLS, CEILINGS OR FLOORS UNLESS SPECIFICALLY IDENTIFIED TO BE REMOVED. 11. PROTECT ADJACENT SURFACES AND FEATURES FROM DAMAGE DURING PROTECT ADJACENT SURFACES AND FEATURES FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION. THE CONTRACTOR IS RESPONSIBLE TO RESTORE TO ORIGINAL CONDITION ITEMS OR AREAS DAMAGED DURING CONSTRUCTION. 12. DIMENSIONS ARE BASED ON FIELD MEASURED DIMENSIONS AND OBSERVATIONS. DIMENSIONS ARE BASED ON FIELD MEASURED DIMENSIONS AND OBSERVATIONS. ALL DIMENSIONS ARE APPROXIMATE. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. 13. EXISTING FACILITIES MAY BE CUT, DRILLED, ALTERED, REMOVED OR EXISTING FACILITIES MAY BE CUT, DRILLED, ALTERED, REMOVED OR TEMPORARILY REMOVED AND REPLACED DURING THE PERFORMANCE OF THIS CONTRACT. WORK REPLACED SHALL MATCH EXISTING. THE CONTRACTOR IS RESPONSIBLE TO RESTORE TO ORIGINAL CONDITION ITEMS OR AREAS DAMAGED DURING CONSTRUCTION. 14. CONTRACTOR SHALL SUBMIT A REQUEST TO INTERRUPT ANY SUCH SERVICES TO CONTRACTOR SHALL SUBMIT A REQUEST TO INTERRUPT ANY SUCH SERVICES TO OWNER/ARCHITECT, IN WRITING, 48 HOURS IN ADVANCE OF PROPOSED INTERRUPTION. REQUEST SHALL STATE REASON, DATE, EXACT TIME OF, AND APPROXIMATE DURATION OF SUCH INTERRUPTION. 15. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE OWNER'S SECURITY CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE OWNER'S SECURITY REQUIREMENTS FOR THE SITE AND BUILDING AREA UNDER CONSTRUCTION. 16. CONTRACTOR SHALL INSTALL ALL NEW MATERIALS, FINISHES AND EQUIPMENT CONTRACTOR SHALL INSTALL ALL NEW MATERIALS, FINISHES AND EQUIPMENT PER MANUFACTURER'S INSTRUCTIONS. 17. THE CONTRACTOR SHALL REPAIR ANY DAMAGES DUE TO CONSTRUCTION THE CONTRACTOR SHALL REPAIR ANY DAMAGES DUE TO CONSTRUCTION TRAFFIC OR OPERATIONS. 18. THE LOCATION OF PIPING AND EQUIPMENT, AS SHOWN ON THE DRAWINGS, IS THE LOCATION OF PIPING AND EQUIPMENT, AS SHOWN ON THE DRAWINGS, IS DIAGRAMMATIC AND SCHEMATIC AND IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH ALL OTHER TRADES BEFORE PERFORMING ANY WORK. 19. CONTRACTOR TO PHOTOGRAPH AND DOCUMENT EXISTING CONDITIONS PRIOR TO CONTRACTOR TO PHOTOGRAPH AND DOCUMENT EXISTING CONDITIONS PRIOR TO STARTING DEMOLITION AND CONSTRUCTION. 20. PATCH AND REPAIR EXISTING SUBSTRATES THAT ARE TO REMAIN AS REQUIRED PATCH AND REPAIR EXISTING SUBSTRATES THAT ARE TO REMAIN AS REQUIRED TO PREPARE THEM FOR NEW WORK AND FINISHES AS DEFINED ELSEWHERE IN THE DOCUMENTS. 21. PROVIDE A COPY OF THE PROGRAMMING FOR THE INSTALLED EQUIPMENT TO PROVIDE A COPY OF THE PROGRAMMING FOR THE INSTALLED EQUIPMENT TO THE OWNER. 22. PROVIDE A COPY OF ALL SCHEMATICS FOR THE INSTALLED EQUIPMENT TO THE PROVIDE A COPY OF ALL SCHEMATICS FOR THE INSTALLED EQUIPMENT TO THE OWNER. 23. ALL INSTALLED SYSTEMS SHALL BE NON-PROPRIETARY. ALL INSTALLED SYSTEMS SHALL BE NON-PROPRIETARY. 24. PROVIDE THE OWNER WITH ALL PASSCODES OR PROGRAMMING KEYS TO THE PROVIDE THE OWNER WITH ALL PASSCODES OR PROGRAMMING KEYS TO THE INSTALLED EQUIPMENT.
AutoCAD SHX Text
OTTAWA
AutoCAD SHX Text
DELAWARE
AutoCAD SHX Text
ADAIR
AutoCAD SHX Text
CHEROKEE
AutoCAD SHX Text
SEQUOYAH
AutoCAD SHX Text
ROGERS
AutoCAD SHX Text
WASHINGTON
AutoCAD SHX Text
NOWATA
AutoCAD SHX Text
OSAGE
AutoCAD SHX Text
WAGONER
AutoCAD SHX Text
MCINTOSH
AutoCAD SHX Text
OKMULGEE
AutoCAD SHX Text
CREEK
AutoCAD SHX Text
SEMINOLE
AutoCAD SHX Text
HUGHES
AutoCAD SHX Text
OKFUSKEE
AutoCAD SHX Text
PITTSBURG
AutoCAD SHX Text
TULSA
AutoCAD SHX Text
MAYES
AutoCAD SHX Text
HASKELL
AutoCAD SHX Text
MUSKOGEE
AutoCAD SHX Text
CRAIG
AutoCAD SHX Text
KAY
AutoCAD SHX Text
NOBLE
AutoCAD SHX Text
GRANT
AutoCAD SHX Text
GARFIELD
AutoCAD SHX Text
PAYNE
AutoCAD SHX Text
POTTAWATOMIE
AutoCAD SHX Text
CANADIAN
AutoCAD SHX Text
KINGFISHER
AutoCAD SHX Text
OKLAHOMA
AutoCAD SHX Text
CLEVELAND
AutoCAD SHX Text
LOGAN
AutoCAD SHX Text
WOODS
AutoCAD SHX Text
MAJOR
AutoCAD SHX Text
HARPER
AutoCAD SHX Text
WOODWARD
AutoCAD SHX Text
GREER
AutoCAD SHX Text
KIOWA
AutoCAD SHX Text
WASHITA
AutoCAD SHX Text
DEWEY
AutoCAD SHX Text
CUSTER
AutoCAD SHX Text
BLAINE
AutoCAD SHX Text
CADDO
AutoCAD SHX Text
ALFALFA
AutoCAD SHX Text
LINCOLN
AutoCAD SHX Text
PAWNEE
AutoCAD SHX Text
BEAVER
AutoCAD SHX Text
CIMARRON
AutoCAD SHX Text
TEXAS
AutoCAD SHX Text
BECKHAM
AutoCAD SHX Text
MILLS
AutoCAD SHX Text
ELLIS
AutoCAD SHX Text
ROGER
AutoCAD SHX Text
LE FLORE
AutoCAD SHX Text
MC CURTAIN
AutoCAD SHX Text
CHOCTAW
AutoCAD SHX Text
COAL
AutoCAD SHX Text
BRYAN
AutoCAD SHX Text
ATOKA
AutoCAD SHX Text
PUSHMATAHA
AutoCAD SHX Text
GARVIN
AutoCAD SHX Text
MURRAY
AutoCAD SHX Text
LOVE
AutoCAD SHX Text
CARTER
AutoCAD SHX Text
STEPHENS
AutoCAD SHX Text
JEFFERSON
AutoCAD SHX Text
COMANCHE
AutoCAD SHX Text
JACKSON
AutoCAD SHX Text
TILLMAN
AutoCAD SHX Text
COTTON
AutoCAD SHX Text
MARSHALL
AutoCAD SHX Text
JOHNSTON
AutoCAD SHX Text
PONTOTOC
AutoCAD SHX Text
HARMON
AutoCAD SHX Text
MCCLAIN
AutoCAD SHX Text
GRADY
AutoCAD SHX Text
LATIMER

A101

FLOOR PLAN

& DETAILS

B

D

C

E

A

320 S Boston Ave, Suite 100

Tulsa, Oklahoma 74103

918.587.6158

gh2.com

08-09-2021

AutoCAD SHX Text
101B
AutoCAD SHX Text
101A
AutoCAD SHX Text
2
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
EXISTING STAGE
AutoCAD SHX Text
EXISTING DOOR REMAINS
AutoCAD SHX Text
EXISTING DOOR REMAINS
AutoCAD SHX Text
EXISTING DOOR REMAINS
AutoCAD SHX Text
EXISTING DOORS REMAIN
AutoCAD SHX Text
UP
AutoCAD SHX Text
CONCOURSE THEATER
AutoCAD SHX Text
AV ROOM
AutoCAD SHX Text
FIXED AUDIENCE SEATING NOT SHOWN FOR CLARITY QTY.: 226
AutoCAD SHX Text
AREA OUTSIDE SCOPE OF WORK
AutoCAD SHX Text
ADJUST LOCATIONS OF ALL CEILING MOUNTED DEVICES AS REQUIRED FOR NEW PARTITIONS, INCLUDING, BUT NOT LIMITED TO LIGHTING, MECHANICAL GRILLES AND SPRINKLER HEADS. RELOCATE AND / OR ADJUST CEILING ACCESS PANEL AS REQUIRED.
AutoCAD SHX Text
PLYWOOD ON OUTSIDE EDGE OF STUD ON THIS SIDE OF WALL - REFER TO DETAIL C/A101
AutoCAD SHX Text
REMOVE EXISTING CARPET AND PROVIDE NEW CARPET (ALTERNATE)
AutoCAD SHX Text
NEW RESILIENT TRANSITION STRIP AT CARPET (ALTERNATE)
AutoCAD SHX Text
EXISTING FLOORING TO REMAIN
AutoCAD SHX Text
EXISTING WOOD RAIL AT EDGE OF STAGE REMAINS
AutoCAD SHX Text
EXISTING LOW WALLS TO REMAIN
AutoCAD SHX Text
EXISTING RAMPS AND HANDRAILS TO REMAIN
AutoCAD SHX Text
NOTE: EXISTING FLOOR ACCESS PANELS AT STAGE REMAIN. LOCATIONS NOT SHOWN.
AutoCAD SHX Text
REMOVE EXISTING FIXED AUDIENCE SEATING AS REQUIRED FOR INSTALLATION OF NEW CARPET (ALTERNATE)
AutoCAD SHX Text
EXISTING STEP REMAINS
AutoCAD SHX Text
EXISTING STAIRS AND HANDRAILS REMAIN
AutoCAD SHX Text
EXISTING THRESHOLD REMAINS
AutoCAD SHX Text
EXISTING VCT REMAINS. REFER TO SPECIFICATION 012700 - UNIT PRICES
AutoCAD SHX Text
EXISTING WOOD BASE REMAINS, TYP.
AutoCAD SHX Text
NEW RESILIENT TRANSITION STRIP AT CARPET (ALTERNATE)
AutoCAD SHX Text
EXISTING FLOORING TO REMAIN
AutoCAD SHX Text
SEATING REPAIR REFER TO ALLOWANCE
AutoCAD SHX Text
REUPHOLSTER EXISTING FIXED AUDIENCE SEATING (ALTERNATE #3)
AutoCAD SHX Text
REMOVE ALL EXISTING AV BOXES THAT ARE NOT BEING REUSED AND PATCH AND REPAIR ANY HOLES THAT REMAIN.
AutoCAD SHX Text
PROVIDE 6" IN-LINE DUCT FAN SYSTEM WITH THERMOSTAT CONTROL. A NEW GRILLE SHALL BE INSTALLED ABOVE THE EQUIPMENT RACK IN THE AV ROOM AND EXHAUSTED TO THE EXTERIOR OF THIS ROOM WITH A NEW GRILLE. BASIS OF DESIGN SHALL BE THE AC INFINITY CLOUDLINE SERIES T6.
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
REFER FLOOR PLANS AND PARTITION TYPES FOR PARTITION CONSTRUCTION
AutoCAD SHX Text
CONT. SEALANT BEAD - BOTH SIDES
AutoCAD SHX Text
DOUBLE RABBIT HOLLOW METAL DOOR FRAME
AutoCAD SHX Text
DOOR RE: SCHEDULE
AutoCAD SHX Text
JAMB ANCHORS MIN. 3 PER JAMB
AutoCAD SHX Text
DOUBLE STUD "JAMB STUD"
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
3-5/8" METAL STUD WALL GYPSUM BOARD STOPS AT CEILING
AutoCAD SHX Text
3 " SOUND 12" SOUND ATTENUATION BATT INSULATION (SAB)
AutoCAD SHX Text
ONE LAYER 5/8" PAINTED GYPSUM BOARD TYPE "X" EACH SIDE
AutoCAD SHX Text
3-5/8" METAL STUD @ 24" O.C. TYP.
AutoCAD SHX Text
1
AutoCAD SHX Text
FLOORING
AutoCAD SHX Text
3-5/8" METAL STUD WALL GYPSUM BOARD ON BOTH SIDES, ONE SIDE OVER ONE LAYER OF 1/2" PLYWOOD
AutoCAD SHX Text
METAL RUNNER TRACK
AutoCAD SHX Text
SOUND ATTENUATION BLANKETS FILL CAVITY
AutoCAD SHX Text
3-5/8" METAL STUD @ 16" O.C. TYP.
AutoCAD SHX Text
EXISTING CEILING
AutoCAD SHX Text
2
AutoCAD SHX Text
1 LAYER OF 5/8" GYPSUM BOARD TYPE "X" - PAINT OVER "" PLYWOOD 34"" PLYWOOD SHEATHING
AutoCAD SHX Text
ONE LAYER OF 5/8" PAINTED GYPSUM BOARD TYPE "X" PAINT
AutoCAD SHX Text
EXISTING CEILING
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
SEALANT
AutoCAD SHX Text
WOOD BASE TO MATCH EXISTING, TYP.
AutoCAD SHX Text
WOOD BASE TO MATCH EXISTING, TYP.
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
U.S. STRUCTURE
AutoCAD SHX Text
SECURE PARTITIONS TO EXISTING CEILING GRID
AutoCAD SHX Text
ADD WALL BRACING TO EXISTING STRUCTURE WHERE REQUIRED FOR WALL STABILITY. PATCH AND REPAIR EXISTING ACT AND GRID AS REQUIRED
AutoCAD SHX Text
TYPE 1
AutoCAD SHX Text
TYPE A
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
TO
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
FROM
AutoCAD SHX Text
DOOR NO.
AutoCAD SHX Text
LOCATION
AutoCAD SHX Text
DOOR SCHEDULE
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
NOTE #1: PROVIDE NEW HARDWARE AS REQUIRED FOR FULLY FUNCTIONAL OPERATION. MATCH EXISTING BUILDING STANDARD MANUFACTURER'S PRODUCTS AND FINISHING. COORDINATE LOCKING AND KEYING WITH OWNER S.W. = SOLID WOOD (STAIN GRADE - MATCH EXISTING DOORS) H.M. = HOLLOW METAL
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MTL
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
MTL
AutoCAD SHX Text
101
AutoCAD SHX Text
-
AutoCAD SHX Text
101A
AutoCAD SHX Text
D/A101
AutoCAD SHX Text
S.W.
AutoCAD SHX Text
A
AutoCAD SHX Text
H.M.
AutoCAD SHX Text
1
AutoCAD SHX Text
101
AutoCAD SHX Text
-
AutoCAD SHX Text
101B
AutoCAD SHX Text
3'-0" X 7'-0" (PAIR)
AutoCAD SHX Text
S.W.
AutoCAD SHX Text
A
AutoCAD SHX Text
H.M.
AutoCAD SHX Text
1
AutoCAD SHX Text
D/A101
AutoCAD SHX Text
SIM
AutoCAD SHX Text
SIM
AutoCAD SHX Text
3'-0" X 7'-0" (PAIR)
AutoCAD SHX Text
LIGHTING LUMINAIRE SCHEDULE
AutoCAD SHX Text
FIXTURE TYPE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BASIS-OF-DESIGN MANUFACTURER / MODEL
AutoCAD SHX Text
A
AutoCAD SHX Text
WALL MOUNTED LED UP/ DOWN SCONCE. DIMMABLE TO 1%
AutoCAD SHX Text
CAMMAN LIGHTING: W120-16 OXFORD (6"X4"X16") 3500K DIFFUSERS: WM FINISH: PAL
AutoCAD SHX Text
QUANTITY (MATCH EXISTING - FIELD VERIFY)
AutoCAD SHX Text
14
AutoCAD SHX Text
NOTES: 1. REMOVE EXISTING REMOVE EXISTING FIXTURES COMPLETE. PREP FOR NEW FIXTURES. PATCH AND REPAIR EXISTING FINISHES AS REQUIRED FOR NEW INSTALLATION. 2. MATCH EXISTING MATCH EXISTING VOLTAGE. 3. NEW LIGHTING TO BE NEW LIGHTING TO BE INTEGRATED WITH A/V CONTROL SYSTEM. 4. PROVIDE TRIM, PROVIDE TRIM, HARDWARE AND REMODEL KITS AS REQUIRED. 5. ALL NEW LOCATIONS ALL NEW LOCATIONS TO MATCH EXISTING.
AutoCAD SHX Text
B1
AutoCAD SHX Text
ROUND LED DOWNLIGHT RECESSED IN EXISTING ACT. DIMMABLE TO 1%
AutoCAD SHX Text
CAMMAN LIGHTING: 4DR (4.5" TO MATCH EXISTING - FIELD VERIFY) 3500KTRIM / FLANGE: OPEN REFLECTOR / STANDARD FINISH: CLEAR ANODIZED "SILVER"
AutoCAD SHX Text
46
AutoCAD SHX Text
B2
AutoCAD SHX Text
ROUND LED DOWNLIGHT RECESSED IN EXISTING ACT. DIMMABLE TO 1%
AutoCAD SHX Text
CAMMAN LIGHTING: 8DR (8" TO MATCH EXISTING - FIELD VERIFY) 3500KTRIM / FLANGE: OPEN REFLECTOR / STANDARD FINISH: CLEAR ANODIZED "SILVER"
AutoCAD SHX Text
22
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
FIRST FLOOR PLAN
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text
JAMB (HEAD SIMILAR)
AutoCAD SHX Text
SCALE: 3" = 1'-0"
AutoCAD SHX Text
PARTITION TYPES
AutoCAD SHX Text
SCALE: 3/8" = 1'-0"
AutoCAD SHX Text
DOOR & FRAME TYPES
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
KEY PLAN
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
VIEW FROM STAGE
AutoCAD SHX Text
VIEW FROM SEATING
AutoCAD SHX Text
NOTES: EXISTING PAINTED STEEL HANDRAILS TO REMAIN. CONTRACTOR TO EVALUATE CONDITION OF PAINT. REFER TO SPECIFICATION 012700 - UNIT PRICES
AutoCAD SHX Text
120V GENERAL POWER CIRCUIT: FURNISH AND INSTALL NEW 20 AMP, 12O VOLT CIRCUIT. FEED FROM NEAREST 120 VOLT PANEL WITH ADEQUATE SPACE AND AMPACITY. .
AutoCAD SHX Text
1

STANDARD TECHNOLOGY LEGENDNOT ALL SYMBOLS AND NOTES MAY BE USED

DATA OUTLET LOCATION(S) INSTALLED ON WALL. CONTRACTOR SHALL PROVIDE (1) 1" CONDUIT PATHWAYFROM EACH LOCATION TO THE NEAREST ACCESSIBLE CEILING SPACE TO A 1-GANG BACK BOX. COORDINATEDATA AND POWER LOCATIONS SO THAT DATA AND POWER ARE AT THE SAME HEIGHT AND IN CLOSEPROXIMITY. CONTRACTOR SHALL PROVIDE AND INSTALL DATA CABLING TO 1-GANG BACK BOX,FACEPLATE(S) AND JACK(S) AS SHOWN ON PLANS. REFERENCE DATA NOMENCLATURE FOR DATA OUTLETQUANTITY AND INSTALLATION HEIGHT AND TYPE.

DATA OUTLET(S) INSTALLED IN FLOOR BOX. CONTRACTOR SHALL PROVIDE AND INSTALL A FLOOR BOX.CONTRACTOR SHALL PROVIDE AND INSTALL (1) 1" CONDUIT PATHWAY FROM NEAREST ACCESSIBLE CEILINGSPACE TO FLOOR BOX LOCATION SHOWN ON PLANS. COORDINATE WITH MEP PLANS AND SHARE COMMONPATHWAY. CONTRACTOR SHALL PROVIDE AND INSTALL DATA CABLING TO FLOOR BOX, FACEPLATE(S) ANDDATA JACK(S) TO EACH LOCATION SHOWN. REFERENCE DATA NOMENCLATURE FOR DATA OUTLET QUANTITYAND INSTALLATION HEIGHT AND TYPE.

DATA OUTLET(S) INSTALLED ABOVE CEILING SPACE. CONTRACTOR SHALL PROVIDE AND INSTALL A 1-GANGBACK BOX 6" ABOVE CEILING. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL 6" OF 1" CONDUITPATHWAY FROM 1-GANG BACK BOX. CONTRACTOR SHALL PROVIDE AND INSTALL DATA CABLING TO 1-GANGBACK BOX, FACEPLATE(S) AND DATA JACK(S) TO EACH LOCATION SHOWN.

PROJECT ABBREVIATIONS

GENERAL PROJECT NOTES

01. ANY DIMENSIONS SHOWN ON THESE DRAWINGS ARE INTENDED TO PROVIDE A GENERAL LOCATION ASREQUESTED BY THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING ALL DIMENSIONS PRIORTO ROUGH-IN AND IMMEDIATELY REPORT ANY CONFLICTS WITH THE OUTLET PLACEMENT TO THE GENERALCONTRACTOR.

02. ALL CABLE BUNDLES WILL BE SUPPORTED EVERY 48"-60" OC WITH A J-HOOK OR OTHER APPROVED PATHWAYDEVICE. REFERENCE SPECIFICATIONS AND DETAILS FOR ADDITIONAL CABLING PATHWAY INSTALLATIONREQUIREMENTS. CONTRACTOR WHO VIOLATES THESE REQUIREMENTS WILL BE REQUIRED TO REPLACE THEAFFECTED CABLE PLANT AT THEIR EXPENSE.

03. PLASTIC TIE WRAPS ARE NOT PERMITTED AT ANY TIME ON THIS INSTALLATION. ALL CABLE ROUGH-IN AND DRESS-OUT WILL BE WITH VELCRO ONLY. ALL CABLES BUNDLED WITH PLASTIC TIE WRAPS SHALL BE IMMEDIATELYREPLACED AT THE CONTRACTOR'S EXPENSE.

04. DO NOT INSTALL ANY CABLES IN ANY CONDUIT SLEEVE, STUB UP, OR WALL CAP WITHOUT A PROTECTIVEBUSHING. CABLES PULLED INTO UNPROTECTED CONDUITS WILL BE REPLACED AT THE CONTRACTOR'S EXPENSE. DONOT INSTALL ANY CABLING INTO ANY CONDUIT THAT HAS NOT BEEN CONFIRMED TO BE BLOWN CLEAR. COORDINATEWITH ELECTRICAL PRIOR TO ROUGH IN OF ANY CABLING.

05. ANY CABLING FOUND PAINTED DURING THE CONSTRUCTION PROCESS WILL BE REPLACED AT CONTRACTOR'SEXPENSE. CONTRACTOR SHALL COORDINATE WITH THE GENERAL CONTRACTOR AND PAINTER TO AVOID CONFLICTS.

06. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REFERENCE BOTH THE PROJECT DRAWINGS AND THEPROJECT SPECIFICATIONS. TOGETHER THEY FORM THE COMPLETE CONTRACT DOCUMENTS. PLEASE REFERENCETHE PROJECT SPECIFICATIONS FOR ALL MATERIALS, EQUIPMENT AND COMPONENTS NOT INDICATED ON THEDRAWING SET.

07. CONTRACTOR SHALL COORDINATE ALL FINAL CAMERA LOCATIONS, HEIGHTS AND CAMERA VIEWING ANGLES WITHOWNER/OWNER'S REPRESENTATIVE. FAILURE TO COORDINATE ALL FINAL CAMERA LOCATIONS, HEIGHTS AND VIEWANGLES MAY REQUIRE RELOCATION OF CONDUITS, CABLE AND CAMERA LOCATIONS AT CONTRACTOR'S EXPENSE.

08. CONTRACTOR SHALL COORDINATE TECHNOLOGY, TELECOM, SECURITY AND AUDIO VISUAL LOCATIONS SO THATDATA AND POWER ARE AT THE SAME HEIGHT AND SPACED 18"-24" APART UNLESS SPECIFIED OTHERWISE.REFERENCE TECHNOLOGY AND MEP SHEETS FOR COORDINATION.

09. ALL CABLING INSTALLED IN AREAS WITH EXPOSED CEILINGS SHALL BE INSTALLED IN A PROPERLY SIZED CONDUITPATHWAY. CONDUIT PATHWAYS SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. THE CONDUIT MAY BEPAINTED TO MATCH CEILING COLOR AS DIRECTED BY THE CONTRACT DOCUMENTS.

10. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO REVIEW THE ARCHITECTURAL DEMOLITION DRAWINGS FORALL DEMOLITION AREAS.

11. CONTRACTOR SHALL DOCUMENT ALL EXISTING TECHNOLOGY, TELECOM, SECURITY AND AUDIO VISUAL DEVICESAND LOCATIONS PRIOR TO DEMOLITION OF CEILINGS AND SPACES. PROVIDE TEMPORARY SUPPORT IN ALLDEMOLITION AREAS FOR DEVICES, RE-INSTALL ALL EXISTING DEVICES IN NEW CEILINGS.

12. CONTRACTOR SHALL DOCUMENT ALL EXISTING CEILING TECHNOLOGY, TELECOM, SECURITY AND AUDIO VISUALLABELING ON EXISTING CEILING GRID. PROVIDE NEW LABELING PER SPECIFICATIONS.

13. CONTRACTOR SHALL BE RESPONSIBLE FOR STOPPING ALL TECHNOLOGY, TELECOM, SECURITY AND AUDIOVISUAL CONDUIT PENETRATIONS FROM WATER OR RODENT INGRESS IN ALL BUILDINGS UPON COMPLETION OF THEPROJECT.

XX #

OUTLET INSTALLATION TYPE:

OUTLET INSTALLATION LOCATION

# INDICATES QUANTITY OF DATA DROPS TOBE INSTALLED

XX#

XX#

XX#

AC - OUTLET INSTALLED IN CEILING SPACEAP - OUTLET INSTALLED ABOVE CEILING FOR ACCESS POINTCC - OUTLET INSTALL 18" ON CENTER AFFFB - OUTLET INSTALLED IN FLOOR BOXFN - OUTLET INSTALLED IN FURNITUREHD - OUTLET INSTALLED AT 44" AFFHG - OUTLET INSTALLED AT 12" AFF UNOMB - OUTLET INSTALLED 6" ABOVE MARKER BOARDML - OUTLET INSTALLED 18" AFF IN MULLIONPI - OUTLET INSTALLED IN CEILING FOR PAGING INTERFACEPOS - OUTLET INSTALLED ABOVE WORK SURFACE FOR POINT OF SALESRW - OUTLET INSTALLED IN RACEWAYSC - OUTLET INSTALLED FOR SURVEILLANCE CAMERATV - OUTLET INSTALLED AT 24" BELOW CEILING HEIGHT UNOVP - OUTLET INSTALLED AT PROJECTOR LOCATIONWS - OUTLET INSTALLED ABOVE WORK SURFACE

DATA SYMBOLS LEGEND

AC - ACCESS CONTROLAFF - ABOVE FINISHED FLOORAHJ - AUTHORITY HAVING JURISDICTIONAV - AUDIO AND VIDEOBBC - BACKBONE BONDING CONDUCTORBICSI - BUILDING INDUSTRY CONSULTING SERVICE INTERNATIONALC - CONDUITCD - CONSTRUCTION DOCUMENTSCCTV - CLOSED CIRCUIT TELEVISIONCO - CONDUIT ONLY (EMPTY CONDUIT WITH MULE TAPE)CP - CONTROL PANELCU - COPPERDR - DOOR RELEASEEC - ELECTRICAL CONTRACTOREF - ENTRANCE FACILITYEL - EMERGENCY LOCK DOWNEP - ENTRANCE POINTEPT - ELECTRONIC POWER TRANSFERESS - ELECTRONIC SAFETY AND SECURITYFBO - FURNISHED BY OTHERSFCC - FEDERAL COMMUNICATIONS COMMISSIONGND - GROUNDHC - HORIZONTAL CROSS-CONNECTHR - HOME RUNHVAC - HEATING, VENTILATION, AND AIR CONDITIONINGIBO - INSTALLED BY OTHERSIDF - INTERMEDIATE DISTRIBUTION FRAMEIEEE - THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERSISP - INTERNET SERVICE PROVIDERJB - JUNCTION BOXLV - LOW VOLTAGEMB - MARKER BOARDMC - MAIN CROSS- CONNECTMDF - MAIN DISTRIBUTION FRAMEMH - MANHOLEMIC - MICROPHONEMMF - MULTI-MODE FIBERMD - MOTION DETECTORMPOE - MAIN POINT OF ENTRYNEC - NATIONAL ELECTRICAL CODENEMA - ATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNIC - NOT IN CONTRACTNTS - NOT TO SCALEOC - ON CENTERPB - PULL BOXPBB - PRIMARY BONDING BUSBARPM - PROJECTOR MOUNTPNL - PANELPOC - POINT OF CONTACTPOE - POWER OVER ETHERNETPOS - POINT OF SALEPP - PATCH PANELRCP - REFLECTED CEILING PLANRFI - REQUEST FOR INFORMATIONRFP - REQUEST FOR PROPOSALRMU - RACK MOUNT UNITSBB - SECONDARY BONDING BUSBARSMF - SINGLE MODE FIBERSMR - SURFACE MOUNTED RACEWAYSW - SWITCHTBC - TELECOMMUNICATION BONDING CONDUCTORTE - TELECOMMUNICATIONS ENCLOSURETIA - TELECOMMUNICATIONS INDUSTRY ASSOCIATIONTYP - TYPICALUG - UNDERGROUNDUL - UNDERWRITERS LABORATORIES INCUNO - UNLESS NOTED OTHERWISEUPS - UNINTERRUPTIBLE POWER SUPPLYUSB - UNIVERSAL SERIAL BUSVC - VOLUME CONTROLVP - VIDEO PROJECTORWAP - WIRELESS ACCESS POINTWP - WEATHER PROOF

WALL MOUNTED AUDIO VIDEO DEVICE. DIVISION 26 REFER TO: KEYNOTES FOR DETAIL, KEYNOTES FORCOORDINATION. AV CONTRACTOR REFER TO DRAWINGS FOR QUANTITIES, SPECIFICATIONS FORMANUFACTURER AND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

AV

AV

M

VP

TP

FB

XX

XX

XX

XX

XX

XX

ERXX

AUDIO VISUAL SYMBOLS LEGEND

PS

RESPONSIBILITY SCHEDULETHIS SCHEDULE IS FOR REFERENCE AND DOES NOT INCLUDE ALL PROJECT COMPONENTS. IT SHALL BE USED IN CONJUNCTION WITH THE PROJECT DRAWINGS AND PROJECT SPECIFICATIONS.

SECTION DESCRIPTION DESIGNED BY: FURNISHED BY: INSTALLED BY:27 0000 COMMUNICATIONS CABLING OTHERS OTHERS OTHERS BY OTHERS

27 4116 INTEGRATED AUDIO-VIDEO EQUIPMENT FIRM RESPONSIBLE FOR DESIGN CONTRACTOR OWNER CONTRACTOR OWNER NOTES

CEILING PROJECTORS

CRUXNA

XNA

CONTRACTOR FURNISHED, CONTRACTORINSTALLED

CEILING PROJECTOR MOUNTS

CRUXNA

X NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

PROJECTOR LIFT CRUX NA X X NA OWNER FURNISHED, OWNER INSTALLED

MICROPHONES / CABLESCRUX

NA X NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

DSP / AMPLIFIER / INPUT SOURCE CRUX NA X X NA OWNER FURNISHED, OWNER INSTALLED

AMPLIFIERS CRUX NA X X NA OWNER FURNISHED, OWNER INSTALLED

DISTRIBUTED SPEAKERS

NA NAX

X NA TO BE EVALUATED AND ADVICE PROVIDED BYCONTRACTOR

PORTABLE SPEAKERS NA NA NA NA NA NOT APPLICABLE TO THIS PROJECT

CONTROL PANEL(S)CRUX

NA X NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

WALL PLATESCRUX

NA X NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

WIRING

CRUX NA X NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

FLOOR BOXES CRUX NA NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

AV RACK CRUX NA NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

AV PATCH CORDSCRUX

NA XNA

CONTRACTOR FURNISHED, CONTRACTORINSTALLED

AV CABLINGCRUX

NA X NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

POWER CONDITIONER / SEQUENCER

CRUX NAX

X NA CONTRACTOR FURNISHED, CONTRACTORINSTALLED

VIDEO WALL CRUX NA X NA ALTERNATE

VWxx

CEILING MOUNTED AUDIO VIDEO DEVICE. DIVISION 26 REFER TO: KEYNOTES FOR DETAIL, KEYNOTES FORCOORDINATION. AV CONTRACTOR REFER TO DRAWINGS FOR QUANTITIES, SPECIFICATIONS FORMANUFACTURER AND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

EQUIPMENT RACK. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AV CONTRACTOR REFER TO:KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FOR MANUFACTURER AND MODELAND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

AUDIO VIDEO FLOOR BOX. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AV CONTRACTORREFER TO: KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FOR MANUFACTURERAND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

CEILING MOUNTED MICROPHONE. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AVCONTRACTOR REFER TO: KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FORMANUFACTURER AND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

CEILING MOUNTED PROJECTION SCREEN. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AVCONTRACTOR REFER TO: KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FORMANUFACTURER AND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

WALL MOUNTED TOUCH PANEL. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AV CONTRACTORREFER TO: KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FOR MANUFACTURERAND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

WALL MOUNTED TOUCH PANEL. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AV CONTRACTORREFER TO: KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FOR MANUFACTURERAND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

XXWP

WALL MOUNTED AUDIO VIDEO WALL PLATE. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AVCONTRACTOR REFER TO: KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FORMANUFACTURER AND MODEL AND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

VIDEO WALL. DIVISION 26 REFER TO KEYNOTES FOR COORDINATION. AV CONTRACTOR REFER TO:KEYNOTES FOR DETAIL, DRAWINGS FOR QUANTITIES, SPECIFICATIONS FOR MANUFACTURER AND MODELAND FUNCTIONAL DRAWINGS FOR CONNECTIVITY.

CONSTRUCTIONDOCUMENTS

© 2020 COPYRIGHT GH2 ARCHITECTS, LLC

SHEET NUMBER:

SHEET NAME:

08/09/2021ISSUE:

ISSUE DATE:

20170013.42GH2 PROJECT NUMBER:

OM

ES

SE

QU

OY

AH

CO

NC

OU

RS

E T

HE

AT

ER

RE

NO

VA

TIO

N

OTHER ISSUE DATES:

NO. DESCRIPTION DATE

OKL

AHO

MA

CIT

Y, O

K

D-GH2-1009-01 - - BF -Project No. PDS SEC AV BIM TG-101

GENERAL NOTESSYMBOLS AND

RESPONSABILITYMATRIX

AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
X
AutoCAD SHX Text
TECHNOLOGY + SECURITY CONSULTING
AutoCAD SHX Text
800.685.6440
AutoCAD SHX Text
www.cruxsolutions.com

FB 01 FB 01

ER34"

60"

10"

FB 02

AV 01

AV 01

FLOOR PLAN/RCP

01

0302

KEYNOTE LEGEND x

04

TP 01

05

AV 02

WP01

38"10"

01

09

VP AV 03

06

07

08

07

CONSTRUCTIONDOCUMENTS

© 2020 COPYRIGHT GH2 ARCHITECTS, LLC

SHEET NUMBER:

SHEET NAME:

08/09/2021ISSUE:

ISSUE DATE:

20170013.42GH2 PROJECT NUMBER:

OM

ES

SE

QU

OY

AH

CO

NC

OU

RS

E T

HE

AT

ER

RE

NO

VA

TIO

N

OTHER ISSUE DATES:

NO. DESCRIPTION DATE

OKL

AHO

MA

CIT

Y, O

K

D-GH2-1009-01 - - BF -Project No. PDS SEC AV BIM T-101

FLOORPLAN / RCP

38"

151"CENTERED TO WALL

PS

02

(NOT ALL KEYNOTES MAY APPLY)

01. DIVISION 26 TO PROVIDE 120V POWER AND 1" CONDUIT FROMFLOOR BOX TO ER (TYPICAL). ALL CONDUIT TO HAVE NYLONGROMMETS AND PULL STRING. SEE DETAIL T-104.

02. DIVISION 26 TO PROVIDE 120V TO RECESSED PROJECTOR AND 1"CONDUIT FROM CONNECTION END TO ER-01. ALL CONDUIT TO HAVENYLON GROMMETS AND PULL STRING.COORDINATE WITH AVCONTRACTOR.

03. DIVISION 26 TO PROVIDE 3- 120V 20A CIRCUITS TO ER (DUPLEXOK) AND 2- 2" CONDUITS WITH NYLON BUSHINGS AND PULL-STRINGFROM RACK TO ACCESSIBLE CEILING LOCATION.

04. DIVISION26 TO PROVIDE 120V POWER AND 1-1/2" CONDUIT FROMFLOOR BOX TO ER (TYPICAL). ALL CONDUIT TO HAVE NYLONGROMMETS AND PULL STRING. SEE DETAIL T-104. CENTER TOSTAGE.

05. MOUNT 48" AFF DIVISION 26 TO PROVIDE 1" EMPTY CONDUIT TOER-01. ALL CONDUIT TO HAVE NYLON GROMMETS AND PULL STRING.COORDINATE WITH AV CONTRACTOR FOR CUSTOM BACK BOX.

06. PROJECTION SCREEN AND LIFT. DIVISION 26 TO PROVIDE 2-GANGQUAD 120V OUTLET ,ONE (1) 1-1/2" CONDUIT AND ONE (1) 1" CONDUITTO ER-01 TO ER-01. ALL CONDUIT TO HAVE NYLON GROMMETS ANDPULL STRING.

07. DIVISION 26 TO PROVIDE 1-1/2" CONDUIT FROM THIS CAMERALOCATION TO ER - 01. ALL CONDUIT TO HAVE NYLON GROMMETSAND PULL STRING.

08. DIVISION 26 TO PROVIDE 1" CONDUIT FROM THIS MICROPHONELOCATION TO ER - 01. ALL CONDUIT TO HAVE NYLON GROMMETSAND PULL STRING.

09. DIVISION 26 TO PROVIDE 1-GANG BOX 18" AFF (OR TYPICAL) WITH1" CONDUIT TO ER-01. ALL CONDUIT TO HAVE NYLON GROMMETSAND PULL STRING.

AutoCAD SHX Text
CONCOURSE
AutoCAD SHX Text
THEATRE
AutoCAD SHX Text
101
AutoCAD SHX Text
TECHNOLOGY + SECURITY CONSULTING
AutoCAD SHX Text
800.685.6440
AutoCAD SHX Text
www.cruxsolutions.com

FB 01 FB 01

ER34"

60"

10"

FB 02

AV 01

AV 01

130"CENTERED TO WALL

FLOOR PLAN/RCP ALTERNATE

01

0302

KEYNOTE LEGEND(NOT ALL KEYNOTES MAY APPLY)

01. DIVISION26 TO PROVIDE 120V POWER AND 1" CONDUIT FROMFLOOR BOX TO ER (TYPICAL). SEE DETAIL T-104.

02. DIVISION 26 TO PROVIDE 120V IN RECESSED RECEPTACLECENTERED ON SUPPORT WALL FOR VIDEO WALL. COORDINATE WITHAV CONTRACTOR.

03. DIVISION 26 TO PROVIDE 3- 120V 20A CIRCUITS TO ER (DUPLEXOK) AND 2- 2" CONDUITS WITH NYLON BUSHINGS AND PULL-STRINGFROM RACK TO ACCESSIBLE CEILING LOCATION.

04. DIVISION26 TO PROVIDE 120V POWER AND 1-1/2" CONDUIT FROMFLOOR BOX TO ER (TYPICAL). SEE DETAIL T-104. CENTER TO STAGE.

05. MOUNT 48" AFF DIVISION 26 TO PROVIDE 1" EMPTY CONDUIT TOER-01. COORDINATE WITH AV CONTRACTOR FOR CUSTOM BACK BOX

06. DIVISION 26 TO PROVIDE 1-GANG BOX 18" AFF (OR TYPICAL) WITH1" CONDUIT TO ER-01. ALL CONDUIT TO HAVE NYLON GROMMETSAND PULL STRING.

07. DIVISION 26 TO PROVIDE 1-1/2" CONDUIT FROM THIS CAMERALOCATION TO ER - 01. ALL CONDUIT TO HAVE NYLON GROMMETSAND PULL STRING.

08.DIVISION 26 TO PROVIDE 1" CONDUIT FROM THIS MICROPHONELOCATION TO ER - 01. ALL CONDUIT TO HAVE NYLON GROMMETSAND PULL STRING..

x

04

TP 01

05

AV 02

WP01

38"10"

01

06

07

08

07

VW01

CONSTRUCTIONDOCUMENTS

© 2020 COPYRIGHT GH2 ARCHITECTS, LLC

SHEET NUMBER:

SHEET NAME:

08/09/2021ISSUE:

ISSUE DATE:

20170013.42GH2 PROJECT NUMBER:

OM

ES

SE

QU

OY

AH

CO

NC

OU

RS

E T

HE

AT

ER

RE

NO

VA

TIO

N

OTHER ISSUE DATES:

NO. DESCRIPTION DATE

OKL

AHO

MA

CIT

Y, O

K

D-GH2-1009-01 - - BF -Project No. PDS SEC AV BIM T-102

FLOORPLAN / RCPALTERNATE

38"

AutoCAD SHX Text
CONCOURSE
AutoCAD SHX Text
THEATRE
AutoCAD SHX Text
101
AutoCAD SHX Text
TECHNOLOGY + SECURITY CONSULTING
AutoCAD SHX Text
800.685.6440
AutoCAD SHX Text
www.cruxsolutions.com

130.7"

73.5"

VIDEO WALL / PROJECTION SCREEN SIZE COMPARISON

CONSTRUCTIONDOCUMENTS

© 2020 COPYRIGHT GH2 ARCHITECTS, LLC

SHEET NUMBER:

SHEET NAME:

08/09/2021ISSUE:

ISSUE DATE:

20170013.42GH2 PROJECT NUMBER:

OM

ES

SE

QU

OY

AH

CO

NC

OU

RS

E T

HE

AT

ER

RE

NO

VA

TIO

N

OTHER ISSUE DATES:

NO. DESCRIPTION DATE

OKL

AHO

MA

CIT

Y, O

K

D-GH2-1009-01 - - BF -Project No. PDS SEC AV BIM T-103

PROJECTION SCREENVIDEO WALL

AutoCAD SHX Text
TECHNOLOGY + SECURITY CONSULTING
AutoCAD SHX Text
800.685.6440
AutoCAD SHX Text
www.cruxsolutions.com

PUSHPUSH

MIC 1 MIC 2PUSH

MIC 3

PUSHPUSH

MIC 4 MONITOR NET

MAKE: ACE BACKSTAGE

BACK BOX: CUSTOMHEIGHT: STAGE FLOOR

02FB

MODEL PNL106, C-15102, C-15141, C-15142, CUSTOM ENGRAVINGMAKE: ACE BACKSTAGE / HALL RESEARCH

BACK BOX: CUSTOMHEIGHT: STAGE FLOOR

01FB

MODEL PNL-107, PE / EX-HDU-WP

NEUTRIK

PUSH

RJ-45

DA-LIFT 15

20.00TO

30.00ADJUSTMENT

31.19 28.98

30.7534.00

33.75

9.50

20.00

PLATE DETAIL

LIFT DETAIL

MAKE:MODEL:

BACK BOX:

HALL RESEARCHEX-HDU-WP1-GANG

HEIGHT: 18" AFF OR TYPICAL

WP 01

5.14

[130.5]

2.83

[72.0]

.54

[13.8]

1.97

[49.9]

.49

[12.5]

1.85

[46.9]

3.42

[87.0]

.86

[21.8]

.60

[15.1]

.36

[9.1]

MAKE: CRESTRON

BACK BOX: CUSTOMHEIGHT: STAGE FLOOR

01FB

MODEL TSW-570

2.29

[58.1]

4.33

[110.1]

.05

[1.2]

1.78

[45.3].24

[6.0]

1.65

[42.0]

3.39

[86.0]

TP-01 DETAIL

CONSTRUCTIONDOCUMENTS

© 2020 COPYRIGHT GH2 ARCHITECTS, LLC

SHEET NUMBER:

SHEET NAME:

08/09/2021ISSUE:

ISSUE DATE:

20170013.42GH2 PROJECT NUMBER:

OM

ES

SE

QU

OY

AH

CO

NC

OU

RS

E T

HE

AT

ER

RE

NO

VA

TIO

N

OTHER ISSUE DATES:

NO. DESCRIPTION DATE

OKL

AHO

MA

CIT

Y, O

K

D-GH2-1009-01 - - BF -Project No. PDS SEC AV BIM T-104

DETAILS

AutoCAD SHX Text
TECHNOLOGY + SECURITY CONSULTING
AutoCAD SHX Text
800.685.6440
AutoCAD SHX Text
www.cruxsolutions.com

RJ45

FB-01

EXISTINGBIAMP NEXIA TC

AUDIO DSP

RJ45

IN OUT

LANTO SWITCH

CISCOSG350-28P

POE SWITCH

RJ45RJ45

RJ45RJ45

RJ45

RJ45RJ45

RJ45RJ45

RJ45

PROJECTOR

RJ45

3.5 AUDIO

INPUTOUTPUT

TRANSFORMER

SWITCH

MIXER

PSTO CONTROL DSP

VDO360USB 2.0

PTZ CAMERA

TP 01

RJ45

AV 01

VDO360USB 2.0

PTZ CAMERA

AV 01

USB EXTENDER

VDO360VUSBEXT-U Rx

USB EXTENDER

VDO360VUSBEXT-U Tx

RJ45

RJ45

USB EXTENDER

VDO360VUSBEXT-U Rx

USB EXTENDER

VDO360VUSBEXT-U Tx

RJ45

RJ45

CPUUSB RJ45

RJ45

Rx

RJ45

Tx

EXISTINGBIAMP NEXIA TC

AUDIO DSP

RJ45

IN

OUT

LANTO SWITCH

RJ45

Rx

RJ45

Tx

SWITCH

SHUREMXWANI8

AUDIO INTERFACE

RJ45

OUT

1

RJ45

2

RJ45

3TO CHARGING STATION

TO ACCESS POINT

TO SWITCH

SHUREMXWANI4

AUDIO INTERFACE

OUT

RJ45

1

RJ45

2

RJ45

3TO CHARGING STATION

TP ACCESS POINT

TO SWITCH

RJ45

CHARGING STATION

SHUREMXWANI4

FROM AUDIO INTERFACE

RJ45

CHARGING STATION

SHUREMXWANI4

FROM AUDIO INTERFACE

FROM AUDIO INTERFACE

FROM AUDIO INTERFACE

FROM AUDIO DSP

FROM AUDIO DSP

RJ45

FB-01

FB-03

RJ45

TO AUDIO DSP

FROM CPU

TO SWITCH

RJ45

FB-01 Rx

CRESTRONHD-RX-101-C-E

FB-01

RJ45FB-02

FB 03

TO FB-01 Rx

TO FB-01 Rx

FROM FB-03FROM FB-03

CRESTRONHD-XSPSURROUND DSP

RJ45

IN OUT

LAN

CRESTRONHD-XSP

BLU-RAY

RJ45

OUT

LANTO SWITCH

TO SWITCH

FROM BLU-RAY

FROM SURROUND DSP

ATLONAAT-AD2

AUDIO CONVERTER

RJ45

CONTROL DSP

CRESTRONCP4

FROM CONTROL DSP

EPSONL1500UHNL

RDLTX-J2

PROJECTOR LIFT

DA-LIFT78088WHT

CONTROL DSP

FROM PROJECTOR SCREEN

RJ45RJ45

RJ45RJ45

FROM PROJECTOR

CONTROL PANEL

CRESTRONTSW-570-B-S

TO SWITCH

FROM CONTROL PANEL

USB INTERFACE

SHUREANIUSB-MATRIX

FROM SWITCH

FROM BEAMFORMING MICROPHONE

TO USB INTERFACE

USB INTERFACE

SHUREANIUSB-MATRIX

FROM AUDIO DSP

RJ45

RJ45

RJ45

RJ45

FROM MEDIA PLAYER

RJ45

BEAMFORMING MICROPHONE

SHUREMXA910

TO USB INTERFACEFROM SWITCH

TO BEAMFORMING MIC

TO USB Rx

TO USB Rx

FROM PROJECTOR LIFT

FROM USB Tx

FROM USB Tx

TO HDMI SWITCH

FB-02 Rx

CRESTRONHD-MD4X1-4K-E

FROM CPU

WIRELESS MOUSE AND KB

IOGEARGKM552R

ER-01

PA-1PA-1

PA-2PA-2

PA-4PA-4

PA-5PA-5

PA-3PA-3

PA-6PA-6

RJ45

RJ45

RJ45

RJ45

RJ45

RJ45

WiFi MEDIA PLAYER

SONOSHUB

RJ45TO SWITCH

AV 03FROM CPU

(HDMI)

TO PROJECTOR

FROM HDMI SWITCH

AV 02

FB-01 Rx

CRESTRONHD-RX-101-C-E

WP-01

TO CPU

TO CPU

FROM WP-01

FROM WP-01

CONSTRUCTIONDOCUMENTS

© 2020 COPYRIGHT GH2 ARCHITECTS, LLC

SHEET NUMBER:

SHEET NAME:

08/09/2021ISSUE:

ISSUE DATE:

20170013.42GH2 PROJECT NUMBER:

OM

ES

SE

QU

OY

AH

CO

NC

OU

RS

E T

HE

AT

ER

RE

NO

VA

TIO

N

OTHER ISSUE DATES:

NO. DESCRIPTION DATE

OKL

AHO

MA

CIT

Y, O

K

D-GH2-1009-01 - - BF -Project No. PDS SEC AV BIM T-105

FRONT ENDFUNCTIONAL

AutoCAD SHX Text
TECHNOLOGY + SECURITY CONSULTING
AutoCAD SHX Text
800.685.6440
AutoCAD SHX Text
www.cruxsolutions.com

PA1A

PA1B

QSCCX502

PA2A

PA2B

QSCCX502

PA3A

PA3B

QSCCX502V

PA4A

PA4B

QSCCX502

PA5A

PA5B

QSCCX702

PA6A

PA6B

QSCCX602V

FRONT

SURROUND

SURROUND

BACK

HOUSE CEILING 70V

SUBWOOFER

CONSTRUCTIONDOCUMENTS

© 2020 COPYRIGHT GH2 ARCHITECTS, LLC

SHEET NUMBER:

SHEET NAME:

08/09/2021ISSUE:

ISSUE DATE:

20170013.42GH2 PROJECT NUMBER:

OM

ES

SE

QU

OY

AH

CO

NC

OU

RS

E T

HE

AT

ER

RE

NO

VA

TIO

N

OTHER ISSUE DATES:

NO. DESCRIPTION DATE

OKL

AHO

MA

CIT

Y, O

K

D-GH2-1009-01 - - BF -Project No. PDS SEC AV BIM T-106

BACK ENDFUNCTIONAL

AutoCAD SHX Text
TECHNOLOGY + SECURITY CONSULTING
AutoCAD SHX Text
800.685.6440
AutoCAD SHX Text
www.cruxsolutions.com