Oil-fired mobile space heaters with chimney HM ... 0211672en 002 12.2007 Operator's manual

Oil-fired mobile space heaters with chimney

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Oil-fired mobile space heaters with chimney

Oil-fired mobile space heaters with chimney

HM ...

0211672en 002

12.2007

Operator's manual

Page 2: Oil-fired mobile space heaters with chimney
Page 3: Oil-fired mobile space heaters with chimney

3

Table of contents1. Foreword 5

2. Safety information 6

2.1 General recommendations ....................................................................62.2 Labels ....................................................................................................7

3. Control panel 8

4. Description 9

5. Operation 11

5.1 Installation ...........................................................................................115.2 Using the machine ...............................................................................14

6. Transport 15

7. Maintenance 16

7.1 Cleaning the heat exchanger and the combustion chamber ...............167.2 Cleaning the fan ..................................................................................177.3 Cleaning the burner .............................................................................17

8. Malfunctions, causes, and remedies 18

9. Electric wiring diagram 20

10. Technical data 21

EC Declaration of Conformity 23

Page 4: Oil-fired mobile space heaters with chimney

Table of contents

4

Page 5: Oil-fired mobile space heaters with chimney

5

Foreword1. Foreword

This operator's manual contains information and procedures for thesafe operation and maintenance of your Wacker machine. In the inter-est of your own safety and to prevent accidents, you should carefullyread through the safety information, familiarize yourself with it and ob-serve it at all times.This operator's manual is not a manual for extensive maintenance andrepair work. Such work should be carried out by Wacker Service or au-thorized specialists.

The safety of the operator was one of the most important aspects tak-en into consideration when this machine was designed. Nevertheless,improper use or incorrect maintenance can pose a risk. Please operateand maintain your Wacker machine in accordance with the instructionsin this operator's manual. Your reward will be troublefree operation anda high degree of availability.

Defective components should be replaced immediately!Please contact your Wacker representative if you have any questionsconcerning operation or maintenance.

All rights reserved, especially reproduction and distribution rights.Copyright 2007 Wacker Construction Equipment AG

No part of this publication may be reproduced in any form or by anymeans, electronic or mechanical, including photocopying, without theexpressed written permission of Wacker.Any type of reproduction, distribution or storage on data media of anytype and form not authorized by Wacker represents an infringement ofcopyright and will be prosecuted. We expressly reserve the right to make technical modifications – evenwithout special notice – which aim at further improving our machinesor their safety standards.

Page 6: Oil-fired mobile space heaters with chimney

Safety information HM ...

wagsi5700000003en.fm 6

2. Safety information

2.1 General recommendations

Set up and operate the machine according to the regulations and lawsin effect.Observe the following points:

* Strictly follow the instructions in this manual.

* Do not place the machine in areas with a high risk of fire or explo-sion.

* Do not store highly flammable materials in the vicinity of the ma-chine (minimum distance 3 m).

* All fire prevention measures must be met.

* Ensure that the ventilation of the room where the machine is locatedis sufficient and corresponds to the requirements of the machine.

* Place the machine near a flue and supply a control panel for the ma-chine which has the technical data required to operate the machine.

* Check the machine before you start it and monitor it during opera-tion. Keep children and pets away from the oil-fired space heaterwith chimney.

* Turn off the machine with the circuit breaker after use.

Always follow the operating instructions. This means, in particular:

* Do not exceed the maximum thermal output of the burner ("Techni-cal data" on page 21).

* Air flow performance must not be below the nominal air flow perfor-mance. Therefore, check the suction and discharge pipes for obsta-cles or blockages.

* Make sure that any cloths or covers are not put on the machine andthat the oil-fired space heater with chimney is not placed directlynear a wall or large bulky objects. The combustion chamber over-heats if the air flow performance is insufficient, the overheating con-tactor thermostat L1 is activated and keeps switching the burner offand on ("Malfunctions, causes, and remedies" on page 18).

Page 7: Oil-fired mobile space heaters with chimney

wagsi5700000003en.fm 7

HM ... Safety information2.2 Labels

Your machine has adhesive labels containing the most importantinstructions and safety information.

* Make sure that all the labels are kept legible.

* Replace any missing or illegible labels.

Item Description

1 CAUTION• Read the operator’s manual carefully.• Privide a sufficient flow of fresh air to closed rooms.• Operate the unit at least 2 m away from combusstible

materials.• Neffer pull out the mains plug during operation or during

the after-cooling phase.• Only use heating oil or diesel fuel (not bio fuels).• Turn off the unit before you fill the tank.

2 Fasten suitable lifting tackle to the machine or attach to the transport lugs.

3 CAUTIONNote the following prior to commissioningThe following are provided in the heater for the first assem-bly:• 2 support feet• 1 axle• 2 wheelsRemove these components prior to commissioning the heater and mount them on the device.

Page 8: Oil-fired mobile space heaters with chimney

Control panel HM ...

wagtx5700000036en.fm 8

3. Control panel

1 Control lamp for voltage 2 Heating - OFF - ventila-tion main switch

3 Power supply cable

4 Overheating contactor thermostat, L1

5 Fan thermostat, F 6 Safety thermostat with manual unlocking device, L2

7 Operating hour meter 8 Cable for warm air filter 9 Overheating control lamp L1, L2

10 Control lamp "Fan OFF" 11 Fan unlocking switch 12 Safety switch for burner

13 Room thermostat

Page 9: Oil-fired mobile space heaters with chimney

wagtx5700000002en.fm 9

HM ... Description4. Description

The oil-fired space heaters with chimney in the HM series heat medi-um-sized and large rooms which require heating that is either mobileor permanently installed.The heat generated by combustion is radiated via the metal surfacesof the combustion chamber with double smoke circulation and via theheat exchanger. This heats up the air in the room.The air flow channel is separated from the smoke channel and bothchannels are hermetically welded and sealed. After cooling down thecombustion products are channelled into an exhaust pipe which mustbe connected to a flue or chimney pipe. In this way, the exhaust fumesare expelled.The air required for the combustion procedure is drawn in directly fromthe room that is to be heated. Therefore, the room must be adequatelyventilated to achieve sufficient air circulation.The final part of the air outlet channel can be replaced with the follow-ing distributors:

* Distributor with 2/4 outlets; all outlet points must remain open.

* Distributor from "Plenum" with four side openings; the air flow canbe diverted in the right direction via an adjustable flap (Figure 1).

CautionDuring operation with a "Plenum" distributor, two of the four sides mustremain open to avoid overheating the combustion chamber.

Figure 1HM oil-fired space heaters with chimney can be used with diesel oilburners which operate in the ON-OFF mode.

Page 10: Oil-fired mobile space heaters with chimney

Description HM ...

wagtx5700000002en.fm 10

CautionOnly use the approved burners supplied by the manufacturer. The CEmarking on the machine is no longer valid if the burner is replaced byone that is not approved, even if it has similar features.Burner operation is monitored by three safety devices which are acti-vated when there is a serious malfunction.The burner control unit stops operation if the flame goes out and is in-stalled on the burner housing and fitted with a restart button. The L2safety thermostat with manual locking device stops operation if thecombustion temperature exceeds the set limits (control lamp (9) lightsup). The RM thermo relay stops operation, if the power requirementsof the fan motor exceed the limit (control lamp (10) lights up).If one of these safety devices has been triggered, the cause of the mal-function must be found. Repair any damage before pressing the restartbutton and starting up the oil-fired space heater with chimney again("Malfunctions, causes, and remedies" on page 18).The L1 overheating contactor thermostat switches the machine off, ifthe air flow for cooling the combustion chamber is insufficient. The oil-fired space heater with chimney switches on again automatically assoon as the temperature has dropped below the safety limit (controllamp (9) lights up first and goes out again).

Page 11: Oil-fired mobile space heaters with chimney

wagtx5700000013en.fm 11

HM ... Operation5. Operation

5.1 Installation

CautionOnly qualified personnel are permitted to carry out the steps describedin this section.

5.1.1 Power connections and settingsThe oil-fired space heaters with chimney include all the operation andthe control and safety devices required as standard: Electrical controlpanel, burner, fan thermostat, overheating contactor thermostat andsafety thermostat with manual locking are aleady connected.CautionThe electric power supply cable for the machine must be earthed andhave a fault current protective switch.The electric power supply cable must be connected to a control panelwith a circuit breaker.

Carry out the the following steps:

* Check the supply rates on the sticker and connect the power supplycable to the mains.

* Connect the burner to the burner supply pipe (Operator's manual forburners).

* Connect the burner to a suitable socket.

Before starting up the machine, compare the electrical connectionswith the circuit diagram.For the initial start up of the oil-fired space heater with chimney, ensurethat the power requirements of the fan do not exceed the rates given.Adjust the burner according to the instructions in the burner operator'smanual.

Page 12: Oil-fired mobile space heaters with chimney

Operation HM ...

wagtx5700000013en.fm 12

. 5.1.2 Connecting to the hot air discharge pipeThe oil-fired space heater with chimney is designed for operating withdirect air distribution.The air outlet plate can be replaced by a distributor with 2 or 4 outlets,if the warm air flow needs to go into pipes. In this case, remove theoriginal air outlet plate. Remove the screws that hold down the air out-let plate onto the housing of the oil-fired space heater with chimney.Mount the distribution part with 2 or 4 outlets. Alternatively, the air out-let plate can be replaced by the "Plenum" distributor (Figure 1). In thiscase, replace the original air outlet plate with the front plate and attachthe "Plenum" distributor to the above remaining angle profile.With the exception of "Plenum", the distributor parts can be connectedto the pipes with suitable diameters, if required for a particular purpose.As the vales for the airflow can vary, the following checks are alwaysnecessary if any changes have occurred in the distribution of warm air(changes in the length of pipe, amount of curves, etc.):

* Ensure that the power requirements of the fan motor do not exceedthe values given.

* Ensure that the air flow corresponds to the nominal air flow.

5.1.3 Connecting to the exhaust pipeThe exhaust pipes must be steel and conform to the EN 1443 stan-dard.Burner performance and proper burner operation depend on the flueflow. The connection to the flue must be in accordance with the regu-lations of the law in effect. Note the following regulations:

* The exhaust pipe must be as short as possible and face upwards.

* Avoid narrow bends and shortening diameters.

* A stack must be provided for each oil-fired space heater with chim-ney.

* The flue flow must correspond to the minimum value stated.

Page 13: Oil-fired mobile space heaters with chimney

wagtx5700000013en.fm 13

HM ... Operation. 5.1.4 Analyzing the combustion products

To check the composition of combustion products and the temperatureof the smoke, the probes seen in Figure 2 must be installed.After completing the checks, seal the hole for the probes with a mate-rial which will ensure the pipes are sealed even at high temperatures.

Figure 25.1.5 Setting combustion - initial start up

Once the sealing for the pipe connections and the smoke circulationhas been checked, the initial start up of the oil-fired space heater withchimney can take place. To set combustion correctly, analyze the com-bustion products using an appropriate measuring instrument and en-sure the values correspond to the valid guidelines.Take the settings from the burner operating manual. Each setting mustbe made after an inspection of the smoke composition. The CO2 levelsmust correspond to an excess air factor of approx. 1.2 (12.5 for dieseloil), and the CO level must be under 75 ppm.

Page 14: Oil-fired mobile space heaters with chimney

Operation HM ...

wagtx5700000013en.fm 14

. 5.2 Using the machine

5.2.1 Initial start upNote the following when starting up the oil-fired space heater withchimney:

* The main switch (2) must be set to the "0" position.

* Connect the electric power supply. Press the circuit breaker on thecontrol panel.

* When operating manually, set the main switch (2) to position : Theburner starts. After a few minutes of the combustion chamber heat-ing up, the fan starts.

* When operating the machine automatically, set the required tem-perature on the temperature thermostat and put the main switch (2)to position : The machine switches on and off automatically de-pending on whether the room temperature is above or below thetemperature set.

* If the oil-fired space heater with chimney does not work: see section"Malfunctions, causes, and remedies" on page 18. Identify thecause of the malfunction.

5.2.2 Switching off the machineTo switch off the machine, put the main switch (2) to position "0" formanual operation. This is regulated by the room thermostat when themachine is operating automatically. The burner is switched off, the fancontinues to operate until the combustion chamber has completelycooled down.CautionDo not switch off the oil-fired space heater with chimney by pulling theplug out of the control panel.Only disconnect the power supply once the fan has stopped.

5.2.3 VentilationPut the main switch (2) to position to switch on the fan.

Page 15: Oil-fired mobile space heaters with chimney

wagtx5700000018en.fm 15

HM ... Transport6. Transport

For moving and transporting the machine, hold onto the handle at thefront and roll it on its back wheels.CautionBefore moving the machine, carry out the following steps:

* Switch off the machine. Follow the instructions in section "Switchingoff the machine" on page 14.

* Disconnect the electric power supply. Pull the mains plug from thesocket.

* Wait until the oil-fired space heater with chimney has cooled down.

Only lift the machine using the specified lifting equipment. Attach arope or chains to the four lifting points. Before lifting, ensure that theequipment used is able to lift the weight of the machine (see technicaldata).The machines can only be stacked (max. of 2) by using the proper ac-cessories that are standard for the series. Do not move machines thatare stacked.CautionNever lift the machine by hand. Its heavy weight could cause seriousbodily injury.

Page 16: Oil-fired mobile space heaters with chimney

Maintenance HM ...

wagtx5700000022en.fm 16

7. MaintenanceCautionOnly qualified personnel are permitted to carry out the steps describedin this section.Carry out the following maintenance measures regularly to ensuresmooth operation of the machine. Ensure that the power supply is dis-connected before starting.CautionBefore you start maintenance work, carry out the following steps:

* Switch off the machine. Follow the instructions in section "Switchingoff the machine" on page 14.

* Disconnect the power supply using the circuit breaker on the controlpanel.

* Wait until the heater has cooled down.

7.1 Cleaning the heat exchanger and the combustion chamber

To sustain the machine's efficiency and extend its service life, carry outthe cleaning described in this section at least once at the end of everyoperating cycle and more frequently for a build up of excess soot.Heavy build up of soot can occur if, for example, the flue flow is ob-structed, a poor quality fuel is used, the burner is not set correctly or ifthe machine is switched on and off too frequently.Note: If the machine starts vibrating when operating, it could meanthere is a large build up of soot.Access to the heat exchanger (1): Remove the top plate (3). Dismantlethe inspection plate of the smoke cabinet (2). Take out the swirler jig(7).Access to the combustion chamber (4): Remove burner (5).

Page 17: Oil-fired mobile space heaters with chimney

wagtx5700000022en.fm 17

HM ... Maintenance. 7.2 Cleaning the fan

Remove any objects from the grid on the suction side (6) and clean thefan wheel with compressed air, if necessary.

Figure 3

7.3 Cleaning the burner

To ensure the machine operates smoothly: Service the burner regular-ly. Contact an authorized customer service center to have this done.Cleaning, servicing and adjustment measures must be carried out ac-cording to the instructions in the operating manual.CautionAfter servicing, make sure the machine is running properly.

Page 18: Oil-fired mobile space heaters with chimney

Malfunctions, causes, and remedies HM ...

wagtx5700000025en.fm 18

8. Malfunctions, causes, and remedies

Malfunction Cause Remedy

The machine does not start

No electric power

Check the function and position of the main switch

Check the electrical power line

Check electrical connections

Check the fuses are still intact

Main switch is set incorrectly Set main switch properly

Room thermostat does not work properly

Check thermostat setting and adjust correctly

Check thermostat

The safety device (burner, L2 thermostat, fan thermo relay) does not come on after it was repaired

Press the restart button:- Burner (knob on control unit)- L2 thermostat (knob (6))- Fan thermo relay (knob (11))

L1 thermostst activated (control lamp (9) lights up and goes out)

Combustion chamber over-heats

Check fuel supply

Check position of flaps, con-nections, etc.

Remove any possible objects stuck in the air pipes or fan guards

L2 thermostat activated (control lamp (9) lights up)

Combustion chamber over-heats excessively

Check as described above

If the measures described above are not successful, seek technical support from the cus-tomer service center

RM thermo relay activated (control lamp (10) lights up)

Excessive current consump-tion of fan motor

Heater with axial fan: Remove possible obstruction at air suc-tion point; shorten air channel

Heater with centrifugal fan: Check the fan-belt setting ("Connecting to the hot air dis-charge pipe" on page 12)

Always check that the fan's power requirement is below the value on the nameplate

The burner does not start, the flame does not ignite and the control lamp for the restart but-ton lights up on the control unit

The burner does not function properly

If the same situation occurs after pressing the restart button and starting the machine again: Contact the Technical Cus-tomer Service

Page 19: Oil-fired mobile space heaters with chimney

wagtx5700000025en.fm 19

HM ... Malfunctions, causes, and remedies

Fan does not start or only after a delay

No electric powerCheck the fuses are still intact

Check electrical connections

F thermostat is damaged Check the thermostat, set or replace

Motor coil has burned through or has a short

Replace fan motor

Engine condensor has burned through (Mod. "M")

Replace condenser

Motor bearing has seized Replace the engine

The fan is noisy or vibratesObstacle in cooling fins Remove obstacle

Insufficient air circulation Remove all obstacles that impair the air circulation

Insufficient thermal efficiency Insufficient burner thermal out-put

Contact the Technical Cus-tomer Service

Malfunction Cause Remedy

Page 20: Oil-fired mobile space heaters with chimney

Electric wiring diagram HM ...

wagtx5700000030en.fm 20

9. Electric wiring diagram

M Fan motor SB "Ventilator OFF" control lamp

PA Bushing room thermo-stat

F Fan thermostat BR Burner L1 Overheating contactor thermostat

FB Fuse for 6 A burner TA Room thermostat L2 Safety thermostat with manual unlocking device

TM Remote switch for fan C Condenser RV Heating - OFF - ventila-tion switch

RM Thermo relay for fan PB Bushing burner SL Overheating control lamp L1, L2

ST Control lamp for voltage CO Operating hour meter

Page 21: Oil-fired mobile space heaters with chimney

wagtd5700000003en.fm 21

HM ... Technical data

10. Technical data

HM 105 HM 133 HM 174

Item number 0610118 0610119 0610120

Max. thermal output [kcal/h][kW]

90,000 104.70

115,000 133.70

150,000174.42

Air flow performance [m3/h] 6,000 8,000 10,500

Net thermal output1

1. With Ecoflam-burner

[kcal/h][kW]

79,650 92.62

101,890 118.48

131,250152.62

Thermal efficiency rate, h

% 88.5 88.6 87.5

Voltage [V] 230 1~

Frequency [Hz] 50

Oil consumption [kg/h] 8.82 11.27 14.71

Smoke temperature [°C] 260 220 249

Smoke flow rate [Nm3/h] 213 223 306

Fan motor current consumption

[W] 1,060 1,500 1,860

Total current consumption1

[W] 1,240 1,690 2,120

Static pressure avail-able

[mm H2O] 10 10 10

Fume resistance1 [mbar] 1 1 1

Required flue flow1 [mbar] 0.1 0.1 0.1

Flue connection diameter

[mm] 150 200 200

Warm air discharge connection

[mm] 500 515 600

Fan thermostat acti-vating temperature

[°C] 30 30 30

Temperature monitor [°C] 85 85 85

Noise level at 1 m1 [dBA] 78.1 79.6 82

Dimensions,L x W x H

[mm] 1,520 x 960 x 702 1,695 x 1,090 x 772 1,895 x 1,230 x 724

Weight [kg] 160 195 250

Page 22: Oil-fired mobile space heaters with chimney

Technical data HM ...

wagtd5700000003en.fm 22

Page 23: Oil-fired mobile space heaters with chimney

EC Declaration of Conformity

Wacker Construction Equipment AG, Preußenstraße 41, 80809 München

certifies that the construction machine:

Type:

Oil-fired mobile space heaters with chimney

fulfills the requirements of the directive 89/392/EC with amendments 91/368, 93/44,93/68, and 98/37.

The machine was constructed in accordance with the following directives:

89/336/EC92/31/EC73/23/EC

Type HM 105 HM 133 HM 174

Machine type number 0610118 0610119 0610120

Installed thermal output [kW] 104.70 133.0 174.42

Dr. Stenzel

Head of Research and Development

Plea

se k

eep

this

doc

umen

t in

a sa

fe p

lace

Page 24: Oil-fired mobile space heaters with chimney

Wacker Construction Equipment AG - Preußenstraße 41 - 80809 München - Tel.: +49-(0)89-3 54 02-0 - Fax: +49-(0)89-3 54 02-390Wacker Corporation - P.O. Box 9007 - Menomonee Falls, WI 53052-9007 - Tel.: +1 (1) 262-255-0500 - Fax: +1 (1) 262-255-0550 - Tel.: 800-770-0957Wacker Machinery Ltd.- Skyline Tower, Suite 2303, 23/F, 39 Wang Kwong Road, Kowloon Bay, Hong Kong -Tel.: +852 2406 6032 -Fax: +852 2406 6021

Page 25: Oil-fired mobile space heaters with chimney
Page 26: Oil-fired mobile space heaters with chimney