Oil Condensing Boilers
UltraOil® 16-600 kWDescription 120Technical Data and Dimensions 122Accessories 142Typical Hydraulic Schematics 155
Hoval reserve the right to make changes without prior notice August 2017 - Rev 00 1
DESCRIPTION
Hoval UltraOil®
We offer a range of exclusive service contracts for our UltraOil boilers
Easy to use Sophisticated
• Low heating costs due to the latest condensing boiler design with aluFer® heat exchanger
• Improved electrical consumption due to large water content
• Low maintenance due to self-cleaning effect
• User-friendly touchscreen controls with TopTronic®E system
• Convenient remote monitoring using TopTronic® online
• Minimum sulphur emissions due to the use of ultra low sulphur heating oil
• Low CO2 emissions due to minimal fuel consumption
• Clean and economical due to fewer burner start-ups
• Space-saving due to compact design
• Time-saving installation due to flexible connection options
• Simple integration into existing systems or new builds
Simple maintenance
Low emissions
Economical EcologicalPatented aluFer®
heat exchanger
Versatile operation
UltraOil® 16-600kW
Hoval reserve the right to make changes without prior notice2 August 2017 - Rev 00
The Hoval UltraOil®, with output rates of 16 to 600 kW, has been specially developed for operation with the latest generation of low-sulphur heating oil. The latest condensing technology and the patented aluFer® heat exchanger together allow the Hoval UltraOil® to extract every last bit of heat from each drop of oil.
Hoval aluFer® technology
The internationally patented aluFer® tube is a Hoval innovation in advanced heat transfer technology. It is constructed from an inner aluminium finned surface, heat shrunk within an outer stainless steel tube. The exceptional efficiency of the heat transfer is attributed to the following factors:
• High heat conductivity of aluminium being ten times greater than that of steel
• A ten times larger heat exchange surface due to the internal finned surface of the aluminium tube
• Optimised turbulence and heat exchange efficiency created by the multiple flow channels on the inner surface of the tube
Ultra environmentally friendly:The advanced Hoval UltraOil® should only be used with Ultra Low Sulphur oil (<0.005% by weight or <50ppm sulphur content) complying to BS2869 Class A2. The sulphur content of this heating oil is equivalent to that of natural gas. Thus, the sulphur emissions drop to almost zero, meaning there are fewer deposits in the combustion chamber and a lower environmental impact. Your heating system can therefore offer a consistently high efficiency rate and less maintenance is required.Standard kerosine gas oil to BS2869 Class C2 is not suitable.
Ultra economical and compact:Due to the latest condensing technology, the Hoval UltraOil®
produces a significantly higher energy yield. With the patented aluFer® heat exchanger, maximum heat is extracted from the combustion flue gases and transmitted to the heating water, resulting in a standard efficiency in excess of 104% net. The Hoval UltraOil® combines a very high output and ingenious technology with a compact design.
Ultra flexible:The Hoval UltraOil® does not require a minimum water flow rate1, a minimum water return temperature or a minimum boiler temperature. It can therefore be integrated simply and cost-effectively into your heating system. As the flue gases are cool, an inexpensive plastic flue pipe is suitable.
1 See note 2 in Technical Data section
Sophisticated management for your heating system, the TopTronic® E control is the brain of every Hoval system. Innovative touchscreen technology ensures smooth and continuously monitored operation.
Easy maintenance guaranteed:Numerous, well thought out details ensure low operating costs and high convenience of maintenance in the UltraOil®. All the components are easily accessible, simple to clean and can be rapidly replaced in the event of a fault.
Assembly and delivery:The UltraOil® (16 - 50) boilers are supplied fully assembled, cased and shrink wrapped on a pallet for ease of handling on site. The burner is however supplied seperately for fitting by the installer. The UltraOil® 80-600D are delivered with the casings, burner and control panel packed seperately for fitting by the installer.
Twin return connections:The Hoval UltraOil® is supplied with two separate return connections and active water temperature stratification within the boiler shell is encouraged. The Hoval UltraOil® can be used with an intelligent heating system, where lower temperature circuits with cooler system returns can be connected directly to the boiler to promote condensation and therefore improve operating efficiency. Higher temperature or warmer circuits associated with more conventional system returns are directed to a separate boiler connection. By ensuring that the coldest return circuits are introduced into the boiler without mixing with hotter water – even if in relatively small quantities – the flue gases within the boiler can be brought below their dew point to release as much condensation as possible.
ErP labelling classification for boilers to 70kW.
DESCRIPTION
This boi ler should only be operated with low sulphur heating oi l (with
a sulphur contentof less than 50ppm)complying to BS2869
Class A2
UltraOil® 16-600kW
Hoval reserve the right to make changes without prior notice August 2017 - Rev 00 3
TECHNICAL DATA
Type (16) (20) (25)• Output at 80 / 60 °C kW 11-15 14-19 15-24• Output at 40 / 30 °C kW 16 20 25• Heat input kW 11.3 - 15.5 13.8 - 19.5 15.4 - 24.5• Dimension Space requirements • Maximum boiler operating temperature °C 90 90 90• Minimum boiler operating temperature °C no min. limit• Minimum return flow temperature °C no min. limit• Safety temperature limiter setting (water side) °C 110 110 110• Working / test pressure bar 3.0 / 4.5 3.0 / 4.5 3.0 / 4.5• Boiler efficiency at full load and 80 / 60°C
(related to net / gross calorific value) % 98.3 / 92.7 98.5 / 92.9 98.2 / 92.6• Boiler efficiency at full load and 40 / 30°C
(related to net / gross calorific value) % 103.5 / 97.6 103.9 / 98.0 103.8 / 97.9• Efficiency at part load 30% and return 27°C (according to EN 303)
(related to net / gross calorific value) % 103.9 / 98.0 104.2 / 98.3 104.1 / 98.2• Standing loss qB at 70 °C Watt 220 230 240• Heating gas-side resistance with rated heating capacity,
12.5% CO2,500m over sear level (tolerance +/- 20%) mbar 0.30 0.29 0.29• Condensate volume at 40 / 30 °C l/h 1.07 1.31 1.65• Flow resistance of boiler 1 z value 3.5 3.5 3.5• Water-side resistance at 10 K mbar 6.6 10.6 16.6
at 20 K mbar 1.7 2.6 4.2• Water flow rate at 10 K m3/h 1.38 1.74 2.18
at 20 K m3/h 0.69 0.87 1.09• Boiler water content litres 66 63 68• Insulation thickness mm 80 80 80• Weight (incl. casing, burner) kg 140 145 157• Transport weight kg 134 139 151• Max. electrical power consumption Watt 6/125 6/147 6/175• Noise data with casings (sound power)
Normally ventilated- Heating noise (EN 15036 part 1) dB(A) 61 62 66Room sealed - Heating noise (EN 15036 part 1) dB(A) 53 54 57
• Flue gas mass flow at full output 12.5% CO2 Ultra Low Sulphur oil kg/h 24 31 38• Flue gas temperature at nominal output 80/60 °C °C 75 75 75• Flue gas temperature at nominal output 40/30 °C °C 58 53 56• Delivery pressure at flue gas outlet Pa 50 50 50• Maximum chimney draught Pa -20 -20 -20
1 Flow resistance boiler in mbar = Volume flow (m3/h)2 x z factor2 Although generally the UltraOil® boilers do not require a minimum water flow, it does not mean that the pump and burner can be switched off together when the unit is operating at full output. There should be a pump overrun to dissipate any residual heat within the boiler to avoid nuisance high temperature lockouts.
UltraOil® (16-25)
Hoval reserve the right to make changes without prior notice4 August 2017 - Rev 00
TECHNICAL DATA
Type (35)• Output at 80 / 60°C kW 21 - 33• Output at 40 / 30°C kW 22 - 35• Heat input kW 20.9 - 33.8• Maximum boiler operation temperature °C 90• Minimum boiler working temperature °C no lower limit• Minimum return flow temperature °C no lower limit• Safety temperature limiter setting (water side) °C 110• Working / test pressure bar 3.0 / 4.5• Boiler efficiency at full load and 80 / 60°C
(related to net / gross calorific value) % 98.5 / 92.9
• Boiler efficiency at full load and 40 / 30°C(related to net / gross calorific value) % 103.6 / 97.7
• Efficiency at partial load 30% and return 27°C (according to EN 303)(related to net / gross calorific value) % 104.5 / 98.3
• Standing loss qB at 70°C Watt 250• Heating gas-side resistance with rated heating capacity,
12.5% CO2, 500m over sea level (tolerance +/- 20%)mbar 0.30
• Condensate volume at 40 / 30°C l/h 2.28• Flow resistance of boiler 1 z-value 3.4• Water-side resistance at 10K mbar 30.6
at 20K mbar 7.7• Water flow rate at 10K m3/h 3.0
at 20K m3/h 1.50• Boiler water content Litres 65• Insulation thickness mm 80• Weight (incl. casing, burner) kg 164• Transport weight kg 158• Max. electrical power consumption Watt 213• Noise data with casings (sound power)
Normally ventilated - Heating noise (EN 15036 part 1) dB(A) 63Room sealed - Heating noise (EN 15036 part 1) dB(A) 60
• Flue gas mass flow at full output 12.5% CO2 Ultra Low Sulphur oil kg/h 53• Flue gas temperature at nominal output 40 / 30°C °C 57• Flue gas temperature at nominal output 80 / 60°C °C 75• Delivery pressure at flue gas outlet Pa 40• Maximum chimney draught Pa 20
1 Flow resistance of boiler in mbar = flow rate (m3/h)2 x z-value
2 Although generally the UltraOil® boilers do not require a minimum water flow, it does not mean that the pump and burner can be switched off together when the unit is operating at full output. There should be a pump overrun to dissipate any residual heat within the boiler to avoid nuisance high temperature lockouts.
UltraOil® (35)
5August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
DIMENSIONS (MM)
Type A B C D
UltraOil® (16,20) 1550 805 486 1485UltraOil® (25,35) 1690 945 626 1625
1 Flow heating/safety valve R 1″2 Low-temperature return R 1″3 High-temperature return R 1″4 Flue gas outlet DN 805 Control panel6 Condensate drain (left or right) incl. si-
phon (DN 25) and 2 m PVC plastic tube Ø inside 19 x 4 mm
7 Drain8 Electrical connection9 Acoustic hood
10 Heating pump set (option)
UltraOil® (16-35)
Hoval reserve the right to make changes without prior notice6 August 2017 - Rev 00
SPACE REQUIREMENTS
Boiler door incl. burner swivels upwards and to the left or to the frontA = minimum 150 mm *
- Burner service position in the front - boiler cleaning from the rightA = optimum 300 mm *
- Burner service position left - boiler cleaning from the front - A minimum gap of 160 mm is required to the right of the boiler
* without heating pump set (option)500 mm with heating pump set (option)
- The cleaning aperture must be easily accessible. - Boiler rear side must be accessible.
≥ 50 mm with flue gas silencer
UltraOil® (16-35)
7August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
TECHNICAL DATA
Type (50) (80)• Output at 80 / 60°C kW 28 - 48 58 - 77• Output at 40 / 30°C kW 30 - 50 61 - 80• Heat input kW 28.4 - 48.4 59 - 78• Maximum boiler operation temperature °C 90 90• Minimum boiler working temperature °C no lower limit• Minimum return flow temperature °C no lower limit• Safety temperature limiter setting (water side) °C 110 110• Working / test pressure bar 3.0 / 4.5 3.0 / 4.5• Boiler efficiency at full load and 80 / 60°C
(related to net / gross calorific value) % 98.7 / 93.1 98.4 / 92.6
• Boiler efficiency at full load and 40 / 30°C(related to net / gross calorific value) % 103.5 / 97.6 103.2 / 97.4
• Efficiency at partial load 30% and return 27°C (according to EN 303)(related to net / gross calorific value) % 104.7 / 98.8 104.2 / 98.3
• Standing loss qB at 70°C Watt 290 480• Heating gas-side resistance with rated heating capacity,
12.5% CO2, 500m over sea level (tolerance +/- 20%)mbar 0.75 0.26
• Condensate volume at 40 / 30°C l/h 3.52 5.0• Flow resistance of boiler 1 z-value 1.50 1.5• Water-side resistance at 10K mbar 27.70 71.4
at 20K mbar 6.90 17.9• Water flow rate at 10K m3/h 4.29 6.9
at 20K m3/h 2.15 3.45• Boiler water content Litres 115 135• Insulation thickness mm 80 80• Weight (incl. casing, burner) kg 276 360• Transport weight kg 261 317• Max. electrical power consumption Watt 250 260• Noise data with casings (sound power)
Normally ventilated - Heating noise (EN 15036 part 1) dB(A) 71 64Room sealed - Heating noise (EN 15036 part 1) dB(A) 67 -
• Flue gas mass flow at full output 12.5% CO2 Ultra Low Sulphur oil kg/h 76 126• Flue gas temperature at nominal output 40 / 30°C °C 40 52• Flue gas temperature at nominal output 80 / 60°C °C 75 75• Delivery pressure at flue gas outlet Pa 30 50• Maximum chimney draught Pa 20 20
1 Flow resistance of boiler in mbar = flow rate (m3/h)2 x z-value
2 Although generally the UltraOil® boilers do not require a minimum water flow, it does not mean that the pump and burner can be switched off together when the unit is operating at full output. There should be a pump overrun to dissipate any residual heat within the boiler to avoid nuisance high temperature lockouts.
3 With room control module.
UltraOil® (50-80)
Hoval reserve the right to make changes without prior notice8 August 2017 - Rev 00
DIMENSIONS (MM()
1 Flow heating/safety valve R 1½″2 Low-temperature return R 1½″
2a High-temperature return R 1½″3 Lead-through for oil pipe on left or right side4 LAS flue gas supply air connection C100/150
4a Flue gas connection at the back (option)5 Control panel6 Condensate drain (left or right) incl. syphon
(DN 25) and 2 m PVC plastic tube Ø inside 19 x 4 mm
7 Electrical connection on the left or right hand side
8 Drain9 Connection set (option)
10 Heating pump set (option)
UltraOil® (50)
9August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
DIMENSIONS (MM)
UltraOil® (80)
1 Safety valve R1½" 2 Flow R1½" 3 High temperature-return R1½" 4 Low temperature-return R1½" 5 Drain ½" 6 Flue gas connection, internal D155 7 Cleaning aperture D155 8 Condensate drain DN25 incl. syphon 9 Boiler controls 10 Electrical connection on the left or right hand side 11 Boiler feet 20-80mm adjustable 12 Cut-out for oil pipe on left or right hand side
Hoval reserve the right to make changes without prior notice10 August 2017 - Rev 00
Example calculation for the required corridor widthDoor width T = 800
UltraOil® (80) K =680
x 1072 = Corridor width ≥ 912800
Required minimum width of door and corridor for bringing in the boilerThe following values are the calculated minimum values
T = Door widthK = Corridor widthB = Boiler widthL = Maximum boiler length
K
T
< 150B
L B T = x L K
B K = x L T
DELIVERY DIMENSIONS
Boiler without casing and insulationUltraOil®80
UltraOil® (80)
11August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
SPACE REQUIREMENTS (MM)
UltraOil® 50
UltraOil® 80
UltraOil® (50-80)
Boiler door incl. burner swivels upwards and to the left or to the frontA = minimum 150 mm *
- Burner service position in the front - boiler cleaning from the rightA = optimum 300 mm *
- Burner service position left - boiler cleaning from the front
* without heating pump set 500 mm with heating pump set (heating pump set is optional)
- It must be possible to swing open the hinged door of the boiler with the burner upward and rearward. - Boiler rear side must be accessible.
* The cleaning aperture must be easily accessible. As a result, a minimum distance of 500 mm must be maintained on the cleaning opening side.
Hoval reserve the right to make changes without prior notice12 August 2017 - Rev 00
TECHNICAL DATA
UltraOil® (110-160)
Type (110) (130) (160)• Output at 80 / 60°C kW 78 - 105 99 - 124 114 - 152• Output at 40 / 30°C kW 83 - 110 104 - 130 119 - 160• Heat input kW 80 - 105 100 - 125 115 - 154• Maximum boiler operation temperature °C 90 90 90• Minimum boiler working temperature °C no lower limit• Minimum return flow temperature °C no lower limit• Safety temperature limiter setting (water side) °C 110 110 110• Working / test pressure bar 5.0 / 6.5 5.0 / 6.5 5.0 / 6.5• Boiler efficiency at full load and 80 / 60°C
(related to net / gross calorific value) % 99.0 / 93.4 98.9 / 93.3 98.5 / 92.9
• Boiler efficiency at full load and 40 / 30°C(related to net / gross calorific value) % 104.0 / 98.1 103.8 / 97.9 103.5 / 97.6
• Efficiency at partial load 30% and return 27°C (according to EN 303)(related to net / gross calorific value) % 105.0 / 99.1 104.8 / 98.9 104.5 / 98.6
• Standing loss qB at 70°C Watt 500 500 500• Heating gas-side resistance with rated heating capacity,
12.5% CO2, 500m over sea level (tolerance +/- 20%)mbar 0.24 0.34 0.45
• Condensate volume at 40 / 30°C l/h 7.8 8.7 10.8• Flow resistance of boiler 1 z-value 0.1 0.1 0.1• Water-side resistance at 10K mbar 8.9 12.4 18.8
at 20K mbar 2.2 3.1 4.7• Water flow rate at 10K m3/h 9.4 11.1 13.7
at 20K m3/h 4.7 5.6 6.9• Boiler water content Litres 340 340 340• Insulation thickness mm 80 80 80• Weight (incl. casing, burner) kg 420 420 420• Transport weight kg 370 370 370• Max. electrical power consumption Watt 360 550 550• Noise data with casings (sound power)
Normally ventilated - Heating noise (EN 15036 part 1) dB(A) 65 67 67
• Flue gas mass flow at full output 12.5 % CO2 Ultra Low Sulphur oil kg/h 163.6 193.0 252.0• Flue gas temperature at nominal output 40 / 30°C °C 40 42 48• Flue gas temperature at nominal output 80 / 60°C °C 68 70 75• Delivery pressure at flue gas outlet Pa 80 80 80• Maximum chimney draught Pa 20 20 20
1 Flow resistance of boiler in mbar = flow rate (m3/h)2 x z-value
2 Although generally the UltraOil® boilers do not require a minimum water flow, it does not mean that the pump and burner can be switched off
together when the unit is operating at full output. There should be a pump overrun to dissipate any residual heat within the boiler to avoid nuisance high temperature lockouts.
Hoval reserve the right to make changes without prior notice August 2017 - Rev 00 13
Type (200) (250) (300)• Output at 80 / 60°C kW 147 - 190 180 - 238 215 - 286• Output at 40 / 30°C kW 155 - 200 189 - 250 227 - 300• Heat input kW 150 - 194 182 - 241 218 - 290• Maximum boiler operation temperature °C 90 90 90• Minimum boiler working temperature °C no lower limit• Minimum return flow temperature °C no lower limit• Safety temperature limiter setting (water side) °C 110 110 110• Working / test pressure bar 5.0 / 6.5 5.0 / 6.5 5.0 / 6.5• Boiler efficiency at full load and 80 / 60°C
(related to net / gross calorific value) % 98.0 / 92.5 98.9 / 93.3 98.6 / 93.0
• Boiler efficiency at full load and 40 / 30°C(related to net / gross calorific value) % 103.1 / 97.3 103.8 / 97.9 103.6 / 97.7
• Efficiency at partial load 30% and return 27°C (according to EN 303)(related to net / gross calorific value) % 104 / 98.1 104.9 / 99.0 104.6 / 98.7
• Standing loss qB at 70°C Watt 520 600 600• Heating gas-side resistance with rated heating capacity,
12.5% CO2, 500m over sea level (tolerance +/- 20%)mbar 0.67 0.49 0.61
• Condensate volume at 40 / 30°C l/h 13.5 16.9 20.2• Flow resistance of boiler 1 z-value 0.1 0.1 0.1• Water-side resistance at 10 K mbar 29.4 46.1 66.3
at 20 K mbar 7.3 11.5 16.6• Water flow rate at 10 K m3/h 17.1 21.5 25.8
at 20 K m3/h 8.5 10.7 12.9• Boiler water content Litres 360 295 295• Insulation thickness mm 80 80 80• Weight (incl. casing, burner) kg 450 634 634• Transport weight kg 390 534 534• Max. electrical power consumption Watt 550 830 830• Noise data with casings (sound power)
Normally ventilated - Heating noise (EN 15036 part 1) dB(A) 67 - -
• Flue gas mass flow at full output 12.5% CO2 Ultra Low Sulphur oil kg/h 315.0 393.7 472.5• Flue gas temperature at nominal output 40 / 30°C °C 58 43 50• Flue gas temperature at nominal output 80 / 60°C °C 80 67 71• Delivery pressure at flue gas outlet Pa 50 50 50• Maximum chimney draught Pa 20 20 20
1 Flow resistance of boiler in mbar = flow rate (m3/h)2 x z-value
2 Although generally the UltraOil® boilers do not require a minimum water flow, it does not mean that the pump and burner can be switched off
together when the unit is operating at full output. There should be a pump overrun to dissipate any residual heat within the boiler to avoid nuisance high temperature lockouts.
TECHNICAL DATA
UltraOil® (200-300)
Hoval reserve the right to make changes without prior notice14 August 2017 - Rev 00
TECHNICAL DATA
1 Flow resistance of boiler in mbar = flow rate (m3/h)2 x z-value
2 Although generally the UltraOil® boilers do not require a minimum water flow, it does not mean that the pump and burner can be switched off together when the unit is operating at full output. There should be a pump overrun to dissipate any residual heat within the boiler to avoid nuisance high temperature lockouts.
Note: Hoval UltraOil® 320-600D boilers require twin electrical supplies, twin flow and return connections (if the optional header set is not ordered) and also twin fuel supplies.
Type (320D) (400D) (500D) (600D)• Output at 80 / 60°C kW 114 - 303 147 - 380 180 - 476 215 - 568• Output at 40 / 30°C kW 119 - 320 155 - 400 189 - 500 227 - 600• Heat input kW 115 - 309 150 - 388 182 - 482 218 - 580• Maximum boiler operation temperature °C 90 90 90 90• Minimum boiler working temperature °C no lower limit• Minimum return flow temperature °C no lower limit • Safety temperature limiter setting (water side) °C 110 110 110 110• Working / test pressure bar 5.0 / 6.5 5.0 / 6.5 5.0 / 6.5 5.0 / 6.5• Boiler efficiency at full load and 80 / 60°C
(related to net / gross calorific value) % 98.7 / 93.1 98.2 / 92.6 99.0 / 93.4 98.8 / 93.2
• Boiler efficiency at full load and 40 / 30°C(related to net / gross calorific value) % 103.9 / 98.0 103.4 / 97.5 104.1 / 98.2 103.9 / 98.0
• Efficiency at partial load 30% and return 27°C (according to EN 303)(related to net / gross calorific value) % 104.5 / 98.6 104.0 / 98.1 104.9 / 99.0 104.6 / 98.7
• Standing loss qB at 70°C Watt 1000 1040 1200 1200• Heating gas-side resistance with rated heating capacity,
12.5% CO2, 500 m over sea level (tolerance +/- 20%) mbar 0.45 0.67 0.49 0.61
• Condensate volume l/h 21.6 27.0 20.2 20.2• Flow resistance of boiler 1 z-value 0.1 0.1 0.1 0.1• Water resistance (per boiler) at 10K mbar 75.2 117.6 183.7 264.5• Water resistance (per boiler) at 20K mbar 18.8 29.4 45.9 66.1• Water flow rate (per boiler) at 10K m3/h 27.4 34.3 42.9 51.4• Water flow rate (per boiler) at 10K m3/h 13.7 17.1 21.4 25.7• Boiler water content litre 680 720 590 590• Insulation thickness mm 80 80 80 80• Weight (incl. casing, burner) kg 840 900 1268 1268• Transport weight kg 740 780 1068 1068• Max. electrical power consumption Watt 740 1000 1660 1660• Noise data with casings (sound power)
Normally ventilated
- Heating noise (EN 15036 part 1) dB(A) 72 73 - -• Flue gas mass flow at full output 12.5 % CO2 Ultra Low Sulphur oil kg/h 504 730 784 945• Flue gas temperature at nominal output 40 / 30°C °C 48 58 43 50• Flue gas temperature at nominal output 80 / 60°C °C 75 80 67 70• Delivery pressure at flue gas outlet Pa 40 25 25 25• Maximum chimney draft Pa 20 20 20 20
UltraOil® (320D-600D)
15August 2017 - Rev 00 Hoval reserve the right to make changes without prior notice
DIMENSIONS (MM)
UltraOil® (110-300)
UltraOil® (110-300)
UltraOil® (110-200) UltraOil® (250,300)
1 Flow heating/safety valve DN 65/PN 6 DN 65/PN 6 2 Low temperature return DN 65/PN 6 DN 65/PN 6 3 High temperature return DN 65/PN 6 DN 65/PN 6 4 Flue gas outlet (plastic) D200 D250 5 Siphon and 2 m PVC passage
DN 25D19x3
DN 25D19x3
6 Cleaning aperture D100 D100 7 Drain R 1″ R 1″ 8 Electrical connection, optionally left or right 9 Boiler controller, optionally left or right 10 Condensate drain, optionally left or right R ¾″ R ¾″ 11 Plinth rail 12 Maximum pressure limiter (option) Rp ¾″ Rp ¾″ 13 Safety temperature limiter (option) Rp ½″ Rp ½″ 14 Safety valve connection (option) Rp 1¼″ Rp 1¼″ 15 Expansion (option) Rp 1″ Rp 1″
Type K L M N O P Q R S
UltraOil® (110-160) 680 1524 619 756 1412 1492 740 395 290UltraOil® (200) 690 1722 619 756 1412 1492 701 356 251UltraOil® (250,300) 690 1820 650 797 1483 1602 710 335 230
Type A B C D E F G H I J
UltraOil® (110-160) 1009 844 715 2200 243 1710 153 490 280 610UltraOil® (200) 1009 844 715 2408 238 1918 137 490 277 800UltraOil® (250,300) 1064 899 770 2706 228 2018 135 690 292 888
Return stool piece (optional) Flow stool piece (optional)
Hoval reserve the right to make changes without prior notice16 August 2017 - Rev 00
DIMENSIONS (MM)
1 Flow/safety valve DN 65/PN 61a Flow connection set (option) DN 80/PN 6
2 Low-temperature return DN 65/PN 62a Low-temperature return connection set (option) DN 80/PN 6
3 High-temperature return DN 65/PN 63a High-temperature return connection set (option) DN 80/PN 6
4 Flue gas outlet (320D,400D) Ø305/3154 Flue gas outlet (500D,600D) Ø350/3525 Condensate drain/siphon DN 256 Control panel7 Electrical connection on the left or right hand side8 Fitting pipe flow (option)9 Fitting pipe return (option)
10 Expansion Rp 1″11 Safety valve connection Rp 1¼″12 Maximum pressure limiter (option) Rp ¾″13 Safety temperature limiter (option) Rp ½″14 Motor shut-off valve (option)
UltraOil® type A B C D E F G H I J K L M N O P Q R S
(320D) 2709 2200 252 770 610 680 1412 1492 1955 889 1907 844 106 1794 1009 2123 709 950 1305(400D) 2901 2408 236 767 800 690 1412 1492 1955 889 1907 844 106 1794 1009 2123 709 950 1305(500D, 600D) 3284 2708 398 982 888 690 1483 1600 2063 899 2015 899 51 1849 1064 2278 719 950 1449
UltraOil® (320D - 600D)
UltraOil® (320D - 600D)
17August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
Required minimum width of door and corridor for bringing in the boilerThe following values are the calculated minimum values
B K = x L T
T Door widthK Corridor widthB Boiler widthL Maximum boiler length
K
T
< 150B
L B T = x L K
A B C D E F
UltraOil® (110-160) 1524 1882 1362 1533 735 715UltraOil® (200) 1722 2073 1362 1533 735 715UltraOil® (250,300) 1820 2174 1434 1642 790 770
Vertical installation in case of space problemsDimensions without thermal insulation and casing(Dimensions in mm)
Type A B C D E F
UltraOil® (110-160) 1230 1751 2000 2002 2027 735UltraOil® (200) 1264 1951 2195 2182 2220 735UltraOil® (250,300) 1372 2050 2299 2304 2317 790
DELIVERY DIMENSIONS (MM)
Dimensions without thermal insulation and casingUltraOil 110-300
Note: Boilers can be delivered split down further if required. Please consult Hoval Technical for further information.
UltraOil® (110-300)
Hoval reserve the right to make changes without prior notice18 August 2017 - Rev 00
Example calculation for the required corridor widthDoor width T = 800
UltraOil® (320D) K =735
x 1882 = Corridor width ≥ 1729 (per shell)800
A B C D E F
UltraOil® (320D) 1524 1882 1362 1533 735 715UltraOil® (400D) 1722 2073 1362 1533 735 715UltraOil® (500D,600D) 1820 2174 1434 1642 790 770
Required minimum width of door and corridor for bringing in the boilerThe following values are the calculated minimum values
T = Door widthK = Corridor widthB = Boiler widthL = Maximum boiler length
K
T
< 150B
L B T = x L K
Note: Two separate boiler shells are supplied with twin D boilers.
Note: Boilers can be delivered split down further if required. Please consult Hoval Technical for further information.
DELIVERY DIMENSIONS (MM)
UltraOil 320D - 600D
UltraOil® (320D - 600D)
19August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
Space requirementsfor fitting the side casing 400 mm.The boiler can then be pushed to a position 100 mm away from the wall.
Type A B C D E F
UltraOil® (110-160) 560 360 2353 1492 845 450UltraOil® (200) 560 360 2545 1492 845 450UltraOil® (250,300) 1000 480 2841 1602 900 550
* Important: there must be 700 mm space on the left or right of the boiler so that the boiler door can be swivelled out with the burner.
SPACE REQUIREMENTS (MM)
UltraOil (110-300)
UltraOil® (110-300)
Hoval reserve the right to make changes without prior notice20 August 2017 - Rev 00
UltraOil® type A B C
(320D) 2709 1492 1794(400D) 2901 1492 1794(500D, 600D) 3284 1600 1849
Detailed dimensions and dimensions for installationsee single boiler UltraOil® (160-300)
Dimensions neutralisation unitsee single boiler UltraOil® (160-300)
SPACE REQUIREMENTS (MM)
UltraOil (320D-600D)
UltraOil® (320D-600D)
21August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
– The burner electrical supply must be connected to the boiler’s standard plug-type connection.
– The burner electrical supply cable must be shortened to ensure that the plug has to be disconnected in order to swing out the burner.
Noise AttenuationThe following steps can be taken to reduce noise:
– Make the walls, ceiling and floor of the boiler plant room as solid as possible, fit sound absorbers in the air supply ducting, provide conduit supports and brackets with sound dampening fittings.
– If there are living quarters either above or below the boiler plant room, fit rubber vibration dampers underneath the base channels of the boiler and connect conduits flexibly with flexible connections.
– Connect circulating pumps to the network with flexible connections.
– In order to dampen flame noise in the flue, sound absorbers can be fitted in the flue system (consider leaving space for subsequent installation).
Flue system – Flue systems must comply with current
British Standard & Legislation.– The flue must be gastight, impervious to
moisture, non-corrosive, acid-proof and must be suitable for flue gas temperatures up to 120°C.
– The flue system must be suitable for operation with excess pressure.
– The flue must have an ascending fall in order to ensure that the condensate which forms in the flue system flows back into the boiler where it can be neutralised before being discharged into the drainage system.
– When using plastic flue pipes, a flue gas safety temperature limiter should be provided. With the UltraOil® (50), this is already fitted.
– A flue gas sampling point with a circular internal diameter of 10-21mm must be fitted in the flue pipe.
This sh ould extend through the thermal insulation if fitted. (required for the UltraOil® 16-35, 80-600D.
For the UltraOil® 50 the concentric vertical adaptor with sample points should be fitted close to the boiler).
Flue dimensionsSee Flue system section
Use– Optimum flue gas condensation and energy
saving can be achieved with the lowest possible heating operating temperatures.
– With the lowest outside air temperature, the heating return temperature should be 45°C or less to guarantee best efficiency gain.
Regulations and guidelinesThe following regulations and guidelines must be observed:
– Hoval technical information and installation instructions.
– Relevant British Standards and Guidelines.– Hydraulic and technical control regulations.
Water qualityHeating water:– European standard BSEN 14868: 2005
and VDI guideline 2035 must be observed. Particular note must be taken of the following regulations:
– Hoval boilers and water heaters are suitable for heating systems without significant oxygenation (system type 1 in accordance below with BSEN 14868: 2005).
– Systems with – Continuous oxygenation (e.g. floor
heating without diffusion-proof plastic pipes) or
– Intermittent oxygenation (e.g. frequent topping up required) must be fitted with a system separator
– Treated heating water must be checked at least once per year or more frequently as specified by the inhibitor manufacturer.
– If, in the case of existing systems (e.g. boiler replacement), the water quality of the existing heating water complies with VDI 2035, it is not recommended that the system be refilled. VDI 2035 also applies to top-up water.
– Before filling new systems, or, if applicable, existing systems, the heating system must be professionally cleaned and flushed. The heating system must be flushed before the boiler is filled.
– Components of the boiler / heat exchanger that come into contact with water are made of ferrous materials and stainless steel.
– Due to the risk of stress corrosion cracking in the stainless steel component of the boiler, the combined chloride, nitrate and sulphate content of the heating water must not exceed a total of 50mg/l.
– Once the heating has been in operation for 6 – 12 weeks, the pH value of the heating water should be between 8.3 and 9.5.
Water for filling and topping up the system:– Untreated drinking water is generally most
suitable for filling and topping up a system with a Hoval boiler. However, the water quality of the untreated drinking water must always comply with VDI 2035 or must be demineralised and/or treated with inhibitors. The specifications of BSEN 14868: 2005 must be observed.
– In order to maintain the boiler’s high efficiency level and to avoid overheating of the heating surfaces, the values in the table below must not be exceeded. These values are calculated in relation to the boiler output (the smallest individual boiler in the case of multiple boiler systems) and the water content of the system.
– The total quantity of water used to fill and top up the system during the boiler’s life must not exceed a value equivalent to three times the water content of the system.
Combustion air– A suitable supply of combustion air must be
guaranteed. It must not be possible to close the air supply aperture.
– Minimum free area for the air supply aperture at low level is 6 cm2 per 1kW boiler input.
– Minimum free area for the air supply aperture at high level is 3cm2 per 1kW boiler input.
Oil burner installation– The burner is supplied seperate for
mounting by the installer.– The gap between the burner draught tube
and the boiler refractory must be filled with the insulation material supplied.
Boiler electrical connection– Mains supply 1 x 230V, 50Hz, 10A.– Note twin (UltraOil® D) boilers require two
supplies.
Maximum filling quantity based on VDI 2035Total hardness of filling water up to…
[mol/m3] 1 <0.1 0.5 1 1.5 2 2.5 3 >3.0f°H <1 5 10 15 20 25 30 >30d°H <0.56 2.8 5.6 8.4 11.2 14.0 16.8 >16.8e°H <0.71 3.6 7.1 10.7 14.2 17.8 21.3 >21.3~mg/l <10 50.0 100.0 150.0 200.0 250.0 300.0 >300Conductivity <20 100.0 200.0 300.0 400.0 500.0 600.0 >600Boiler size of individual boiler maximum filling quantity without demineralisation
up to 50 kW NO REQUIREMENT 20 l/kW50 to 300 kW 50 l/kW 20 l/kW 20 l/kW always demineralise
1 Total of alkaline earths2 If the conductivity in µS/cm exceeds the value specified in the table a water analysis must be carried out
D
2 x D 1D
< 2D
D
Flue gastest point
UltraOil® (16-600kW)
Hoval reserve the right to make changes without prior notice22 November 2018 - Rev 01
– In order to ensure reliable burner operation, a GOK combined oil de-aerator, 70 micron oil filter & shut-off valve unit must be fitted between the burner and the oil supply pipe serving each burner. The GOK unit must be mounted at burner height. It is supplied as standard with all UltraOil boilers (two supplied with each UltraOil 'D' boiler). For more information please see the Accessories section - part number 6049368 refers.
– The size and design of the oil distribution pipework should comply with current regulations.
– For UltraOil (16-80) boilers the recommended oil pipework size is 4mm inside diameter and the maximum pipework length in metres is as follows:
Suct ion height H in m
UltraOil®
(16) (20) (25) (35) (50) (65) (80)
0 30 30 30 30 20 14 12
1 30 30 30 23 15 11 9
2 30 29 23 16 10 8 6
3 20 16 13 9 6 - -
– For UltraOil (110-300) boilers the recommended oil pipework size is 6mm inside diameter and the maximum pipework length in metres is as follows:
– The above table is also applicable for UltraOil twin (320-600D) boilers. Both boilers will each require their own oil supply.
– All figures are indicative only and are based on a total resistance (including components, elbows etc) of 40 mbar. If pipework is oversized this can lead to operational issues with the burner.
Expansion vessel / expansion– It is recommended that the system
expansion vessel is connected to the heating system with a suitable connection consisting of a lock shield valve and drain cock as per BS 7074. This means that the entire system will not need to be emptied in order to carry out work on the vessel.
– In the case of open vented, the system height must be such that the required minimum operating pressure is maintained.
Safety valve & automatic air vent– A safety valve and automatic air vent must
be fitted to all boilers.– On the UltraOil® 16-50 and the UltraOil®
(110-600D) these should be fitted on the flow pipework from the boiler, but before any isolation valve.
– On the UltraOil® 80 the seperate safety valve connection can be utilised for both items (utilising a tee piece).
Condensate drain - off- Permission to run the flue gas condensate
into the drainage system must be obtained from the relevant authority.
- The condensate from the flue system can be run off via the boiler. A condensate trap in the flue pipe system is then no longer required.
- A siphon must be fitted at the condensate outlet of the oil-fired condensing boiler (supplied with the boiler). No isolating valve should be fitted in this drainage pipework.
Information concerning heating system replacementIf an existing oil-fired heating system is being replaced by a Hoval UltraOil®, the following points relating to the oil tank and its refilling should be observed:- The Hoval UltraOil® must only be operated
with ultra low sulphur heating oil with a sulphur content < 50ppm (< 0.005%). Complying to BS2869 Class A2
- It is beneficial if the oil tank is cleaned first.- An existing residual quantity of heating oil
in the oil tank may be mixed with ultra low sulphur heating oil provided that the residual oil does not exceed the following proportions of the total content. Residual quantity heating oil
(sulphur content 2000ppm or 0.2%) max 3% of the tank volume. Residual quantity heating oil (sulphur content 1000ppm or 0.1%) max 5% of the tank volume. Residual quantity heating oil
(sulphur content 500ppm or 0.05%) max 10% of the tank volume.
- The tank must be filled completely (100%) in order to achieve the permitted mixing ratio with ultra low-sulphur heating oil, taking into account the remaining residual quantity of heating oil in the tank.
Oil distribution pipework installation
– The UltraOil® (16-80) boilers can only be used with a single pipe system. Max. suction height without intermediate pump 3.5m, Maximum length of pipework is 30m. Please confirm any oil feed designs with Hoval Technical before installation.
– The UltraOil® (110-600D) boilers can only be used with a single pipe system. Max. suction height without intermediate pump 3.5m, Maximum length of pipework is 30m. Please confirm any oil feed designs with Hoval Technical before installation.
– The pipework / flexible connections must be positioned in such a way that the burner lid / burner can be swung out by 90°.
– A shut-off device must be installed at the end of the rigid oil pipe ie: before the flexible connections.
– The highest point of the oil distribution pipework should be 3.5m above the lowest point of the oil tank suction pipe.
– Pipework must be installed to avoid self priming.
– If the highest point of the oil level in the oil tank is higher than the lowest point of the distribution pipework, a solenoid valve must be fitted at the highest point of the oil pipework, as close as possible to the oil tank.
Concentric Flue design UltraOil® 50• An adapter with sample points must
be used (fitted to the boiler flue outlet connection).
• The flue gas is very cool and saturated with moisture so there will be very little or no buoyancy to pull the gases up the chimney.
• The burner fan assists with the evacuation of the flue gases so there may be slight pressurisation of the flue.
• It is permissible for the condensate from the flue system to drain back through the boiler.
• Horizontal flue sections must be inclined back to the boiler (3° minimum) to prevent condensate remaining in the flue.
• Flues must be designed to meet all current regulations / standards.
• See Technical data section for flue gas mass flow rates, temperatures and usable fan overpressure.
• Please refer to the ventilation requirements below.
Flue design UltraOil® 80-600D• A minimum temperature class T120
flue can be used if fitted with an over temperature device.
• The first two metres of flue must be the same diameter as the boiler flue gas connection.
• Single wall flues may be used as it is not necessary to keep the flue gas temperature high.
• The flue gas is very cool and saturated with moisture so there will be very little or no buoyancy to pull the gases up the chimney.
• The burner fan assists with the evacuation of the flue gases so there may be slight pressurisation of the flue.
• Flues must be leak proof against condensate and suitable for pressurised flue gases.
• It is permissible for the condensate from the flue system to drain back through the boiler.
• Horizontal flue sections must be inclined back to the boiler (3° minimum) to prevent condensate remaining in the flue.
• If combustion air ducting is used this should be the same size as the flue.
• Flues must be designed to meet all current regulations / standards.
• On installations with multiple boilers into a single flue the flue system must be designed to prevent any back circulation of flue gases into the plant room.
• See Technical data section for flue gas mass flow rates, temperatures and usable fan overpressure.
• Please refer to ventilation requirements below.
VentilationVentilation air requirements should comply to BS5410-2: current edition.
Suction UltraOil®height H (110) (130) (160) (200) (250) (300)in m0 30 30 30 26 21 171 30 30 26 20 15 122 28 25 18 14 10 8
– A Hoval safety valve and automatic air vent set (c/w pressure gauge) is available as an accessory. (Please see Accessories).
UltraOil® (16-600kW)
Hoval reserve the right to make changes without prior notice November 2018 - Rev 01 23
100/150PP FOR ULTRAOIL 50 ONLY
Accessories
Connection C100/150 to 2xE100PPFor separate routing of flue gases and combustion air.
Recommendation:If the air inlet is near a noise sensitive place (window of bedroom, terrace etc). We recommend the use of a sound absorber on the air inlet. 2015 244
Wall terminal for horizontal discharge 015 072 100
1000mm extension(including support bracket)500mm extension(including support bracket)250mm extension
015 072 420
015 072 410015 072 405
Vertical terminal (black) with cap(including support bracket) 015 072 000
Vertical adaptor Complete with 2 sample points 015 072 400
45 degree elbow 015 072 600
93 degree elbow 015 072 500
Support bracket 015 072 900
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Hoval reserve the right to make changes without prior notice24 August 2017 - Rev 00
100/150PP CONCENTRIC FLUE PARTS FOR ULTRAOIL 50 ONLY
Accessories
.
Lead pitched roof flashing(to suit roof angle 25-45 degrees) 015 07 270
Aluminium flat roof flashing 015 072 800
Wall terminal kit (for horizontal discharge)Comprises of vertical adaptor, 93 degree elbow and 2 wall plates. Max dimension can be extended by use of extension pieces. 015 072 100
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
Ø10
0Ø
150
1095
1135
102152
110
Ø100Ø150
152
102
990 / 490 / 2401000 / 500 / 250
Ø10
0
Ø15
0
Ø10
2Ø
152
9095
100
45°
125135
Ø102
Ø152
93°
125
150
Ø15
0
1230
Ø100Ø150
680
1180
1290
200
160
22° - 45°
390
40
Ø160
165
Ø102Ø152
215
Ø100Ø150
152
102
Ø10
0
Ø15
0
152
102
Ø10
0
Ø15
0
490500
240250
Ø10
0
Ø100
Ø150
Ø100
115
240
140
1220 max
Wallplate
Wallterminal
93 degreebend
Verticaladaptor
Ø80Ø124
Ø100Ø150
155
10
195
430
155
80/125 to 100/150adaptor
Wallplate
All items finished white RAL 9016.
Connection sealfor UltraOil® (80)with clamping flanges Ø 150 mm(e.g. in connection with the Hovalflue gas sound absorber)on Hoval flue gas pipe systems alreadyincluded in the scope of delivery;
2029 956
Horizontal flue gas connection E100PPfor UltraOil® (50)for the conversion of the verticalflue gas connection (series delivery)to a horizontal to rear routedflue gas connection.
6016 933
6017 246 6031 571
6017 245
Boiler plinthfor UltraOil® (16-35)to elevate the condensate drainagemade of steelheight 150 mmpainted anthracite painted
6025 418
Flue gas sound absorberto reduce the flue gas in-duct sound emissions.Mounting position: vertical up to 45°
for Hoval UltraOil® type
Connection on both sides
(16-25) E80(35) E100 (incl. transition E80-E100)(50) integrated(80) E150
Hoval reserve the right to make changes without prior notice August 2017 - Rev 00 25
6034 576
6037 062
6038 526 6038 507 6038 508 6038 509 6038 510
6034 575
TopTronic® E module expansionsfor TopTronic® E basic module heat generator
NoteThe supplementary plug set may have to be ordered to implement functions differing from the standard!
ODER+
NoteThe flow rate sensor set must be provided as well.
TopTronic® E module expansion UniversalTTE-FE UNIExpansion to the inputs and outputs of a con-troller module (basic module heat generator, heating circuit/domestic hot water module, solar module, buffer module) for implementing vari-ous functions
incl. fitting accessories
Can be installed in: Boiler control panel, wall housing, control panel
TopTronic® E module expansionheat accounting TTE-FE WMZ/EBZExpansion to the inputs and outputs forthe basic module heat generator forimplementing the following functions: - Calculating total energy consumption - Calculating the heat generator energy for
heating - Calculating the heat generator energy for
hot water
incl. fitting accessories3x contact sensor ALF/2P/4/T L = 4.0 m
Can be installed in: Boiler control, wall housing, control panel
TopTronic® E module expansion heatingcircuit TTE-FE HKExpansion to the inputs and outputs of the basic module heat generator or the heating circuit/do-mestic hot water module for implementing the following functions: - 1 heating circuit without mixer or - 1 heating circuit with mixer
incl. fitting accessories1x contact sensor ALF/2P/4/T L = 4.0 m
Can be installed in: Boiler control, wall housing, control panel
Flow rate sensor sets (for models 16-80 only)Size Connection Flow rate
l/min
DN 8 G ¾″ 0.9-15DN 10 G ¾″ 1.8-32DN 15 G 1″ 3.5-50DN 20 G 1¼″ 5-85DN 25 G 1½″ 9-150
OR
NoteFor models 110-300 the flow rate sensors must be provided by the installer.
Accessories
ACCESSORIES
Hoval reserve the right to make changes without prior notice26 August 2017 - Rev 00
6034 499 6034 503
6034 571
6037 058 6037 057 6034 574
6037 071 6037 069 6037 070
6037 079 6037 078 6018 867 6022 797
6034 578 6034 579
6034 581
6035 563 6035 564 6035 565
6035 566 6038 533
2055 889 2055 888 2056 775 2056 776
2061 826
6038 551 6038 552
6039 253
Accessories for TopTronic® E
Supplementary plug setfor basic module heat generator (TTE-WEZ)for controller modules and module expansion TTE-FE HK
TopTronic® E controller modulesTTE-HK/WW TopTronic® E heating circuit/
hot water moduleTTE-SOL TopTronic® E solar module TTE-PS TopTronic® E buffer moduleTTE-MWA TopTronic® E measuring module
TopTronic® E room control modulesTTE-RBM TopTronic® E room control modules
easy whitecomfort whitecomfort black
Enhanced language package TopTronic® Eone SD card required per control module Consisting of the following languages:HU, CS, SK, RO, PL, TR, ES, HR, SR, PT, NL, DA
TopTronic® E remote connectionTTE-GW TopTronic® E online LANTTE-GW TopTronic® E online WLAN
SMS remote control unitSystem component SMS remote con-trol unit
TopTronic® E interface modulesGLT module 0-10 VGateway module ModBus TCP/RS485Gateway module KNX
TopTronic® E wall casingWG-190 Wall casing smallWG-360 Wall casing mediumWG-360 BM Wall casing medium with
control module cut-outWG-510 Wall casing largeWG-510 BM Wall casing large with
control module cut-out
TopTronic® E sensorsAF/2P/K Outdoor sensorTF/2P/5/6T Immersion sensor, L = 5.0 mALF/2P/4/T Contact sensor, L = 4.0 mTF/1.1P/2.5S/6T Collector sensor, L = 2.5 m
System housingSystem housing 182 mmSystem housing 254 mm
Bivalent switch
Accessories
ACCESSORIES
27August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
242 902
6015 000
6010 082
CO monitorFor safety shut-off of theboiler on leakage ofcarbon monoxideincl. connection cable
2056 861
Flow temperature guard for underfloor heating system (1 guard per he-ating circuit) 15-95 °C, differential gap 6 K, ca-pillary tube max. 700 mm setting (visible from the outside) inside the housing cover
Clamp-on thermostat RAK-TW1000.SThermostat with strap, without cable and plug
Kit Clamp-on thermostat RAK-TW1000.SThermostat with strap, enclosed cable (4 m) and plug
Immersion thermostat RAK-TW1000.S SB 150Thermostat with pocket ½″ - depth of immersi-on 150 mm, brass nickel-plated
Condensate pumpfor transporting condensation waterinto a higher drainage duct.Including connection line,completely wired,cable and plug for connectionto the boiler controllermax. transport height: 3.5 mDelivery rate up to 120 l/hcombinable with neutralisation boxcan be mounted in boiler socket
6034 771
Neutralisation boxfor transporting condensation water intoa lower lying drainage ductincl. condensate neutralisationincl. neutralisation granulate 3 kgcombinable with condensate pumpcan be mounted in boiler socket
6024 764
Neutralisation granulatefor neutralisation boxRefill set volume 3 kgLife time of one filling:approx. 2-4 years; depending on amountof condensate
2028 906
Condensate pumpfor UltraOil® (50)for transporting condensation waterinto a higher drainage ductIncluding connection linecompletely wiredcable and plug for connectionto the boiler controllerMax. transport height: 3.5 mcombinable with neutralisation boxcan be mounted in boiler socket
6034 772
Neutralisation boxfor UltraOil® 50for transporting condensation water intoa lower lying drainage duct incl.neutralisation granulate 6 kg.Combinable with condensate pump;can be mounted in boiler socket
6012 553
Condensate drainage forHoval UltraOil® (16-35)
Condensate drainage forHoval UltraOil® (50)
Accessories
ACCESSORIES
Hoval reserve the right to make changes without prior notice28 August 2017 - Rev 00
Neutralisation granulatefor neutralisation boxRefill set volume 3 kgLife time of one filling:approx. 2-4 years; depending on amountof condensate
2028 906
Accessories
ACCESSORIES
Condensate box KB 22for UltraOil® (80-300), (320D-600D)For condensate drainage into highersituated drain pipe with delivery pump.Max. delivery height 3.5 m, from1200 kW two delivery pumps necessary.Delivery rate 120 l/hincl. liquid level switch, silicone hose9/13 mm, 4 m long, electrical cable1.5 m with plug
6033 767
Neutralisation box KB 23for UltraOil® (80-300), (320D-600D)Condensate drainage into lower situateddrain pipe without condensatedelivery pumpwith neutralisation12 kg neutralisation granulatePlaced under the boilerUse one box for each boiler.
6001 917
Neutralisation granulatefor neutralisation boxRefill set volume 3 kgLife time of one filling:approx. 2-4 years; depending on amountof condensate
2028 906
Neutralisation box KB 24for UltraOil® (80-300), (320D-600D)for transporting condensation water intoa higher lying drainage duct,max. delivery height 3.5 m, from1200 kW two delivery pumps necessary.Delivery rate 120 l/hincl. liquid level switch, silicone hose9/13 mm, 4 m long, electrical cable1.5 m with plug12 kg granulate
6033 764
Condensate drainage forHoval UltraOil® (80-600D)
Connection set AS25-S/NT/HTfor mounting a heating armaturegroup HA25for UltraOil® (16,20)Suitable for left or right connectionLow/high temperatureConnection set, fully thermally insulatedRigid flow pipe and flexiblereturn flow pipeFor mounting an armature group HA20adapter set DN20 - DN25 necessary.Delivery:Connection set in assembly units,completely packed.
6017 055
Boiler connection setsfor mounting a heating armature group to the boiler Hoval UltraOil® (16-50).Suitable for left or right connection.Low/high temperature version
Delivery• Connection set in assembly units, completely
packed.
August 2017 - Rev 00 29Hoval reserve the right to make changes without prior notice
Accessories
Holding platefor the installation of a loading groupLG25-2/unmixed HA group HA25-2Suited to Hoval boiler connection setAS25Dimension between axes A = 125 mm,installation height H = 60 mm
2022 446
Connection set AS 25-LGfor UltraOil® (16-35)for mounting acompact charging group LG-2Suitable for left or right connection,low-temperature returnconnection set in assemblies,with complete thermal insulationconsisting of flexible tubes
6034 818
ACCESSORIES
Connection set AS32-25-S/NT/HTfor installing anarmature group HA32for UltraOil® (35)connection set, completely heat insulatedRigid flow pipe and flexible returnflow pipe.Suitable for left orright connectionLow/high temperaturefastening materialincl. reduction set 1¼″AG - 1″IGfor boiler connectionAdapter screw connectionDN 25 - DN 32 necessaryDelivery:Connection set in assembly units,completely packed.
6024 455
Connection set AS40-S/NT/HTfor mounting a heating armature groupHA40for UltraOil® (50)Connection set fully thermally insulatedRigid flow pipe and flexible return flowpipe with threaded flange R1½″Suitable for left or right connectionLow/high temperatureAdapter set DN32 - DN40 necessary.DeliveryConnection set in assembly units,complete packet.
6014 848
Adapter set DN20-DN25for the installation of the HA groupDN20 to a wall distributor DN25 ora connection set DN25.Installation height 120 mm
6013 693
AS25-S2/NT/HT Low/high temperaturefor UltraOil® (25,35)Connection set, fully thermally insulatedRigid flow pipe and flexible returnflow pipe.Suitable for left or right connectionof an armature group HA25.For mounting an armature group HA20an adapter set DN20 - DN25 is necessary.Delivery:Connection set in assembly units,completely packed.
6024 985
Hoval reserve the right to make changes without prior notice30 August 2017 - Rev 00
Accessories
ACCESSORIES
Adapter set DN32-DN25for the installation of the HA groupDN32 to a connection set DN25.
6007 191
Adapter fitting DN32-DN40for the installation of the HA groupDN32 to a wall distributor DN40 or aconnection set AS40-S/NT/ HT.
6014 863
6020 519 6020 659
6020 520 6020 521
6023 300
6020 522
6023 301
6014 867
2004 408 2029 652
2004 408 2029 652
2030 392
2030 393
6023 297
2030 397
2030 398
2030 398
2030 399
2030 407 2053 966
Hoval heating armature groups
Heating armature group HA-3BM-Rwith 3-way motorised mixing valve and heat-in-sulating box. Installation right (flow left).HA group - type Pump - type
DN 20 (¾″)Pump with stepless speed controlHA20-3BM-R/AX 12-4 AX12-4HA20-3BM-R/AX 13-4 AX13-4
DN 25 (1″)Pump with stepless speed controlHA25-3BM-R/AX 12-1 AX12-1HA25-3BM-R/AX 13-1 AX13-1
HA25-3BM-R without pump
Pumps for HA25-3BM-Rfor heating armature group HA25-3BM-R wi-thout pump.
A12-1 230 V
A13-1 230 V
DN 32 (1¼″)Pump with stepless speed controlHA32-3BM-R/AX 13-2 AX13-2HA32-3BM-R/A 15-2 A15-2HA32-3BM-R without pump
Pumps for HA32-3BM-Rfor heating armature group HA32-3BM-R wi-thout pump.
A13-2 230 V
A14-2 230 V
DN 40 (1½″)HA40-3M-R without pump
Pumps for HA40-3Mfor heating armature group HA40-3M without pump. Transition pieces and threaded flang es must be ordered separately if necessary.
A14-2 230 VTransition piece Z17Threaded flange Z29
A15-2 230 VTransition piece Z17Threaded flange Z29
A401-1 230 VModulA 40-12 250 PN6-16 230 V
2030 398
Hoval reserve the right to make changes without prior notice August 2017 - Rev 00 31
Accessories
ACCESSORIES
6020 523 6025 429
6020 524 6020 525
6023 327
6020 526
6023 328
2030 392
2030 393
6023 298
2030 397
Heating armature group HA-3BM-Lwith 3-way motorised mixing valve and heat-in-sulating box. Installation left (flow right)
HA group - type Pump - type
DN 20 (¾″)Pump with stepless speed controlHA20-3BM-L/AX 12-4 AX12-4HA20-3BM-L/AX 13-4 AX13-4
DN 25 (1″)Pump with stepless speed controlHA25-3BM-L/AX 12-1 AX12-1HA25-3BM-L/AX 13-1 AX13-1HA25-3BM-L without pump
Pumps for HA25-3BM-Lfor heating armature group HA25-3BM-L wi-thout pump.
A12-1 230 V
A13-1 230 V
DN 32 (1¼″)Pump with stepless speed controlHA32-3BM-L/AX 13-2 AX13-2HA32-3BM-L/A 15-2 A15-2HA32-3BM-L without pump
Pumps for HA32-3BM-Lfor heating armature group HA32-3BM-L wi-thout pump.
A13-2 230 V
A14-2 230 V
6020 527
6020 528 6020 529
6023 324
2004 408 2029 652
6020 530
6023 325
2030 392
2030 393
2030 397
Loading group LG-2Heating armature group HA-2For the connection of a side calorifier or as heating circuit without mixer, with heat- insulating box. Installation right (flow left).LG/HA group type Pump type
DN 20 (¾″)Pump with stepless speed controlLG/ HA20-2/AX12-4 AX12-4
DN 25 (1″)Pump with stepless speed controlLG/ HA25-2/AX 12-1 AX12-1LG/ HA25-2/AX 13-1 AX13-1LG/ HA25-2 without pump
Pumps for LG/ HA25-2for heating armature group LG/ HA25-2 without pump.
A12-1 230 V
A13-1 230 VIntermediate piece Z17Threaded flange Z29
DN 32 (1¼″)Pump with stepless speed controlLG/ HA32-2/AX 13-2 AX13-2LG/ HA32-2 without pump
Pumps for LG/ HA32-2for heating armature group LG/ HA32-2 without pump.
A13-2 230 V
Hoval reserve the right to make changes without prior notice32 August 2017 - Rev 00
Accessories
ACCESSORIES
6019 209 6019 210 6025 295
Actuator NR230-20Bfor three-way valve B3G4602-wire controlOperating voltage 230 V/50 HzTorque 10 NmActuation time 140 smanual/automatic positioningreversible scale forposition indicator 0...10.Complete with installation material.
245 209
Actuator NR230-20Sfor three-way valve B3G460with limit switch2-wire controlOperating voltage 230 V/50 HzTorque 10 NmActuation time 140 smanual/automatic positioningreversible scale forposition indicator 0...10
245 212
Bypass valve DN 20 (½″)for the installation in a HA groupDN 20Pressure range 0.1 to 0.6 barRPM-regulated pumps must be set toa constant speed!
6013 684
Bypass valve DN 20 (½″)for the installation in a HA groupDN 25/32Pressure range 0.1 to 0.6 barRPM-regulated pumps must be set toa constant speed!
6006 989
Bypass valve DN 32 (1 ¼″)for the installation in a HA group DN 32Setting range from 0.6 to 1.5 barMax. flow rate: 1.5 m3/hwith self-sealing screw connection formounting between flow and returnball valveRPM-regulated pumps must be set toa constant speed!
6014 849
Wall bracketfor the installation of a Hoval armature group on the wall.
Dim. between Connection Wall dist.Type centre lines mm Top Bottom mm
DN 20 90 Rp 1″ R 1″ 70,85,100DN 25 125 Rp 1½″ R 1″ 87-162DN 32 125 Rp 2″ R 1½″ 142,167
2039 167 2039 168 2039 169 2039 170
Three-way tap B3G460, PN10 with internal thread connection, brassfor manual operation or with actuator NR..., housing, cover, shaft and segment made of brass, maintenance-free O-ring seal.Left and right-hand installation possible.Operating pressure 10 bar.Max. operating temperature + 110 °C.
Type DNScrew
connection kvs
Operating pressure
bar
B3G460 15 Rp ½″ 2.5 10B3G460 20 Rp ¾″ 6.0 10B3G460 25 Rp 1″ 12.0 10B3G460 32 Rp 1¼″ 18.0 10
Hoval reserve the right to make changes without prior notice August 2017 - Rev 00 33
Accessories
ACCESSORIES
Safety set SG15-1″Suitable up to max. 50 kWcomplete with safety valve (3 bar)Pressure gauge and automatic air ventwith cut off valveConnection: 1″ internal thread
641 184
Safety set SG20-1″Range of application to 100 kWcomplete with safety valve (3 bar)Pressure gauge and autom.aspirator with shut-off valve.Connection: DN20 1″ internal thread
6014 390 Installation example
Hoval reserve the right to make changes without prior notice34 August 2017 - Rev 00
Accessories
ACCESSORIES
Manual oil priming pumpThe GOK manual oil priming pump is designed to prime the UltraOil burner by pulling oil through the burner oil supply pipe up to the vent port on the burner oil pump. The priming pump is recommended to remove air from the oil pipe system prior to operating the fuel oil pump and burner
2073 718
Automatic oil de-aerator and oil filter unit
GOK combined de-aerator, 70 micron oil filter and shut-off valve unit with 3/8” BSP female inlet & outlet connections suitable for all sizes of UltraOil boilers.Supplied with 2 x 3/8” BSP male to male oil hose connectors.The unit de-aerates internally and therefore no external vent pipe is necessary. It is supplied as standard with each UltraOil boiler (two supplied with each twin UltraOil ‘D’ boiler). Suitable for indoor use.
6049 368
Replacement oil filter insert for the above itemThis oil filter should be replaced annually (two required for each twin UltraOil 'D' boiler).Filter gauge 70 micron
2074 044
35November 2018 - Rev 01Hoval reserve the right to make changes without prior notice
Accessories
Maximum pressure limiter setsuitable for use with the above flow and return stool pieces to meet the safety requirementsof EN 12828 > 300 kW (single boiler)or SWKI 93-1 > 70 kW.Consisting of:- adjustable maximum pressure limiter- safety temperature limiter RAK-ST.131 and cock
Two sets required per UltraOil 'D’ twin boiler
6025 358
Flow and return stool piecesfor assembly on flow and high or low temperature return of the Hoval UltraOil® (110-600D) boiler.Complete with gasket, nuts and bolts for connection of- safety valve 1¼″- an additional safety temperature limiter and a maximum pressure limiter set on the flow- an expansion vessel on the return (not by Hoval)Two sets required per UltraOil ‘D’ twin boilerPart no. 6025 358 below also required
Dimension Suitable for UltraOil® Connection
DN 65 (110-300 & 320D-600D) flow 6032 993DN 65 (110-300 & 320D-600D) return 6023 108
Further information see “Dimensions”
Flow stool piece
Return stool piece
6038 472
Flow/return, pipework headers, DN 65 / PN 6for UltraOil® (320D-600D) Hydraulic connection set for double boiler incl. motorised shut-off butterfly valves.Stool pieces must also be ordered with this hy-draulic connection set (flow/return).
6001 926
6002 660 Hydraulic motorised shut-off butterfly valves PN 6for UltraOil® (320D-600D)for direct mounting in flow and/or return. As option if no flow/return set will be ordered. Complete with cabling.1 piece DN 65Two sets required per UltraOil ‘D’ twin boiler
High-temperature return DN 65 / PN 6for UltraOil® (320D-600D)Pipework header set for double boiler(e.g. for return from calorifier charging circuit).
High-temperature return
ACCESSORIES
Hoval reserve the right to make changes without prior notice36 August 2017 - Rev 00
UltraOil® boiler with Direct Heating Circuit
SV
Typical Hydraulic Schematics
RBM Control module AF Outdoor sensor VF1 Flow sensor 1VF2 Flow sensor 2SF Calorifier sensorB1 Flow temperature thermostat (series connection with pump)MK1 Pump mixed circuit 1MK2 Pump mixed circuit 2SLP Calorifier loading pumpYK1 Actuator mixer 1YK2 Actuator mixer 2HT High temperature returnNT Low temperature return
ATS Anti-thermal siphon dip to prevent gravity circulation
TPV Temperature and pressure relief valve
TD Tundish to drainSV Safety ValveAAV Automatic air ventSTB Safety temperature limiterPmax Pressure limiterTTE-GW GatewayTTE-WEZ Base module heat generatorTTE-FEHK Extension module
TD ATS
1
A
B
D
E
C
F
2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
D
E
C
F
BEBE005.dwg
Achtung ! Für die Installation muss das anlagenbezogene Schema verwendet werden!Attention! This is just a schematic. For installation please use the detail-plan!Attenzione! Per la messa in opera, utilizzare le schema dettagliato!Attention! Pour la réalisation pratique de l'installation, il faut utiliser le schéma détaillé!
Datum:
Datei:Version:
Blatt:
Hydr. Verbindungshinweise /Notice / Nota / Remarque:
1 4.1...
29.01.2015BEBE005 Name:
AF
RBM
TTE-GW
TTE-WEZ
DKP
T T
B1
P
HT
NT
UltraOil
AAV
Notes :- This hydraulic schematic just shows the basic principle. The installation must be in accordance with local regu-lations.- With underfloor heating an over temperature thermostat has to be installed.- Anti thermal siphon dip has to be installed.- up to eight boilers can be linked together to provide sequence control (option)- Oil supply pipework is not shown
TYPICAL HYDRAULIC SCHEMATICS
August 2017 - Rev 00 37Hoval reserve the right to make changes without prior notice
UltraOil® boiler with - Free standing calorifier- Direct heating circuit- 1 or 2 mixed heating circuits
RBM Control module AF Outdoor sensor VF1 Flow sensor 1VF2 Flow sensor 2SF Calorifier sensorB1 Flow temperature thermostat (series connection with pump)MK1 Pump mixed circuit 1MK2 Pump mixed circuit 2SLP Calorifier loading pumpYK1 Actuator mixer 1YK2 Actuator mixer 2HT High temperature returnNT Low temperature return
ATS Anti-thermal siphon dip to prevent gravity circulation
TPV Temperature and pressure relief valve
TD Tundish to drainSV Safety ValveAAV Automatic air ventSTB Safety temperature limiterPmax Pressure limiterTTE-GW GatewayTTE-WEZ Base module heat generatorTTE-FEHK Extension module
1
A
B
D
E
C
F
2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
D
E
C
F
BEBE030.dwg
Achtung ! Für die Installation muss das anlagenbezogene Schema verwendet werden!Attention! This is just a schematic. For installation please use the detail-plan!Attenzione! Per la messa in opera, utilizzare le schema dettagliato!Attention! Pour la réalisation pratique de l'installation, il faut utiliser le schéma détaillé!
Datum:
Datei:Version:
Blatt:
Hydr. Verbindungshinweise /Notice / Nota / Remarque:
1 4.1...
19.03.2015BEBE030 Name:
AF
RBM
TTE-GW
MK1
T T
VF1
YK1
DKP
T T
SLP T
T
MK2
T T
B1.2VF2
YK2
B1.1
TTE-WEZ
TTE-FEHK
SF
T
B1
P
HT
NT
UltraOil
AAVSV
ATSTDTPV
Notes :- This hydraulic schematic just shows the basic principle. The installation must be in accordance with local regu-lations.- With underfloor heating an over temperature thermostat has to be installed.- Anti thermal siphon dip has to be installed.- up to eight boilers can be linked together to provide sequence control (option)- Oil supply pipework is not shown
Typical Hydraulic Schematics
TYPICAL HYDRAULIC SCHEMATICS
Hoval reserve the right to make changes without prior notice38 August 2017 - Rev 00
Notes :- This hydraulic schematic just shows the basic principle. The installation must be in accordance with local regulations.
- With underfloor heating an over temperature thermostat has to be installed.
- Anti thermal siphon dip has to be installed.
- up to eight boilers can be linked together to provide sequence control. (option)- Oil supply pipework is not shown.
RBM Control module AF Outdoor sensor VF1 Flow sensor 1VF2 Flow sensor 2SF Calorifier sensorB1 Flow temperature thermostat (series connection with pump)MK1 Pump mixed circuit 1MK2 Pump mixed circuit 2SLP Calorifier loading pumpYK1 Actuator mixer 1YK2 Actuator mixer 2HT High temperature returnNT Low temperature return
ATS Anti-thermal siphon dip to prevent gravity circulation
TPV Temperature and pressure relief valve
TD Tundish to drainSV Safety ValveAAV Automatic air ventSTB Safety temperature limiterPmax Pressure limiterTTE-GW GatewayTTE-WEZ Base module heat generatorSB-Y4 OFA 200 Flue damper control relayRBM Room Station
ATS
AAVSV
TD
1
A
B
D
E
C
F
2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
D
E
C
F
BEDE010.dwg
Achtung ! Für die Installation muss das anlagenbezogene Schema verwendet werden!Attention! This is just a schematic. For installation please use the detail-plan!Attenzione! Per la messa in opera, utilizzare le schema dettagliato!Attention! Pour la réalisation pratique de l'installation, il faut utiliser le schéma détaillé!
Datum:
Datei:Version:
Blatt:
Hydr. Verbindungshinweise /Notice / Nota / Remarque:
1 4.1
BEDE010(KAE010) Name:
16.11.2015
. . .
DETAILS:+ siehe Kesselfolgeschaltungen-Systeme+ look cascade-systems+ vedi cascata-sistemi+ voir cascade-système
YK1
MK1
T T
B1.1VF1
SF
T
SLP T
T
DKP
T T
MK2
T T
B1.2VF2
YK2P
HT
NT
UltraOil
P
HT
NT
UltraOil
Y10.1 Y10.2
TTE-WEZ
AF
RBM
TTE-GW
TTE-WEZSB-Y4OFA200
SB-Y4OFA200
TD
SV AAV
UltraOil® (320D - 600D) boiler with - Free standing calorifier- Direct heating circuit- 1 or 2 mixed heating circuits
Typical Hydraulic Schematics
TYPICAL HYDRAULIC SCHEMATICS
39August 2017 - Rev 00Hoval reserve the right to make changes without prior notice
Hoval at Titanic BelfastAugust 2017 - Rev 00