Pierre Beeckman Philips Innovation Services

May 23, 2014

Objective testing of flicker and stroboscopic effects resulting from mains voltage fluctuations

Page 2: Objective testing of flicker and stroboscopic effects resulting from

2 May 23, 2014 Philips Innovation Services

• Modeling & Simulations • Design Methods & Tools • Standardization

• Design reviews • Risk analysis • Trainings & audits

• (Pre-)compliance EN, IEC/CISPR, FCC, ETSI • ISO/IEC 17025 accreditation

Technology development

Consultancy Testing

Competences:

EMC

PQ

ESD

SI / PI

EMF

Wireless

EMC Center Philips Innovation Services

Page 3: Objective testing of flicker and stroboscopic effects resulting from

3 May 23, 2014 Philips Innovation Services

Introduction

Page 4: Objective testing of flicker and stroboscopic effects resulting from

Why ‘flicker’ matters

Human impact

• Headaches

• Neurological problems: photosensitive epilepsy

• Autistic sensitivity

• Performance reduction

Safety

• Distraction

• Possible hazard from stroboscopic effect: apparent

stopping or slowing of motion of machinery

4 May 23, 2014 Philips Innovation Services

Page 5: Objective testing of flicker and stroboscopic effects resulting from

5 May 23, 2014 Philips Innovation Services

Different types of temporal light artefacts

Flicker

• The perception of temporal changes in the intensity

(luminance flicker) or color (chromatic flicker) of the light

Stroboscopic effect

• The perception that objects illuminated by fluctuated

• light move discretely rather than continuously

Ghost effect (phantom array)

• The perception of a spatially extended series of light spots

when making a saccade across a light spot that fluctuates

over time

Page 6: Objective testing of flicker and stroboscopic effects resulting from

6 May 23, 2014 Philips Innovation Services

Root Cause: light output modulation Light source technology • Incandescent, fluorescent, solid-state: inherently they have different flicker/strobo properties

Drivers • Electronics convert AC mains to ‘DC’ LED current and voltage • Always some ripple in the LED current will remain which translates toripple in the light output • Suppressing the ripple requires buffering which costs money, physical space, and impacts lifetime

Dimming • Dimming SSL sources is challenging particularly with phase-cut dimmers • Wide variation & no standard test procedure

Camera interactions • Artifacts also result from camera's interaction; especially sensitive for high-speed cameras

Mains voltage fluctuations • Arising from the grid or from other connected equipment or systems

Dimmer voltage

‘variations’ supply

Driver

Light source technology

EMC/PQ

Page 7: Objective testing of flicker and stroboscopic effects resulting from

7 May 23, 2014 Philips Innovation Services

Examples light ripple due to driver & dimming

single stage SMPS

dual stage SMPS

linear (tapped-linear driver)

linear (quasi-DC)

some examples for major driver categories

examples of SSL lamp + phase-cut dimmer

Page 8: Objective testing of flicker and stroboscopic effects resulting from

Visibility: when can people see the stroboscopic effect and flicker?

Flicker influence quantities • frequency • mean luminance • retinal position of the stimulus • size of the stimulus • shape of the waveform (e.g. sinusoidal, squares) • adaptation state of the observer • perceptual load of the observer

Metrics (using light output):

• Flicker Index 𝐹𝐼 = 𝐴𝑟𝑒𝑎 1

𝐴𝑟𝑒𝑎 2+𝐴𝑟𝑒𝑎 1

• Modulation depth (flicker percent)

MD =𝐿𝑚𝑎𝑥 − 𝐿𝑚𝑖𝑛

(𝐿𝑚𝑎𝑥+ 𝐿𝑚𝑖𝑛) ∗ 100%

• IEC short-term flicker metric (Pst)

• Philips Stroboscopic Visibility measure (SVM)

light output

8 May 23, 2014 Philips Innovation Services

Frequency dependent ‘summation’ of spectrum of light output

Page 9: Objective testing of flicker and stroboscopic effects resulting from

9 May 23, 2014 Philips Innovation Services

Standardization activities

Page 10: Objective testing of flicker and stroboscopic effects resulting from

Future: diversity of lighting technologies & diversity of voltage-fluctuation immunity performance

requires flicker immunity test

Voltage fluctuations: low-frequency EMC

∆U voltage ‘variations’

on the mains

Appliances (threat)

Lighting equipment (victim)

Emission test: IEC 61000-3-3 voltage changes , -fluctuations & flicker (regular & fast)

EMC

Until now: no flicker immunity test for lighting equipment; incandescent

lamp is considered the most sensitive apparatus connected to a

LV-mains

11 May 23, 2014 Philips Innovation Services

Page 11: Objective testing of flicker and stroboscopic effects resulting from

10 May 23, 2014 Philips Innovation Services

IEC flickermeter: emulates average perception of flicker from a 60 W incandescent lamp IEC

Mains voltage + variations

∆U

Un

Various flicker metrics and limits for various product categories: Pst

Plt

Pinst

d dmax

Limits & test conditions in

IEC 61000-3-3

flickermeter (IEC61000-4-15) emulating 60 W lamp + eye/brain response

Page 12: Objective testing of flicker and stroboscopic effects resulting from

12 May 23, 2014 Philips Innovation Services

Flicker and stroboscopic effect testing preparatory work IEC TC34-MT1 on future objective immunity test method lighting equipment IEC TR 61547-1

Page 13: Objective testing of flicker and stroboscopic effects resulting from

IEC voltage flickermeter & the light flickermeter

Mains voltage

13

light flickermeter

Model 60 W incandescent lamp

Light output

IEC 61000-3-3 flickermeter

May 23, 2014 Philips Innovation Services

Flicker metrics

Page 14: Objective testing of flicker and stroboscopic effects resulting from

Block diagram PInS test setup Flicker & strobo metrics:

General: MD: Modulation depth/flicker percent FI: Flicker index

Philips: SVM: Strobo effect visibility measure FVM: Flicker visibility measure

IEC: Pst: short-term flicker

Synthesized a.c. mains +

(optional) voltage fluctuations

NEMA SSL 7A phase cut dimmer

(optional)

Light flicker- and

stroboscopic effect meter

EUT Light sensor

Measurement test voltage properties

Metrics

General: rms, max, min, mean

IEC: d: relative voltage fluctuation Pst: short-term flicker

14 May 23, 2014 Philips Innovation Services

Page 15: Objective testing of flicker and stroboscopic effects resulting from

Photograph setup Ulbricht sphere including EUT &

CIE compliant light sensor

NI USB-6251 data acquisition

16 bits; 16 inputs, 2 outputs

Test voltage signal generation

&

Calculation of flicker & strobo metrics

using Matlab

Chroma 61601 amplifier

Inverto Light sensor amplifier

Tektronix DPO 4104

Oscilloscope (monitoring)

15 May 23, 2014 Philips Innovation Services

Page 16: Objective testing of flicker and stroboscopic effects resulting from

All test levels (Pst=1) for immunity testing (draft of IEC TR 61547-1)

16

Rectangular amplitude modulations with duty cycle of 50 % 1) 3) 4)

Voltage changes per minute Frequency

Relative voltage fluctuation

d =∆U/U

(cpm) (Hz) (%)

39 0,3250 0,894

110 0,9167 0,722

1056 8,8 0,2752)

1620 13,5 0,407

4000 33,3 2,343

NOTE 1 – See Table 5 of IEC 61000-4-15

NOTE 2 – See Table 2b of IEC 61000-4-15 for P inst =1; the value of d = 0,196 % is increased to 0,275 % to give Pst =1

NOTE 3 –Duration of the voltage fluctuation recommended to be minimally 60 seconds

NOTE 4 – Recommended absolute tolerance for the duty cycle is ±2 %, for the modulation frequency the recommended tolerance is ±1 % and for the relative voltage fluctuation the recommended tolerance is ±2 %

1

May 23, 2014 Philips Innovation Services

Page 17: Objective testing of flicker and stroboscopic effects resulting from

Example test voltage fluctuation (1) EUT: 9 W self-ballasted CFL lamp

Test voltage: d = 0,407 % @ 13,5 Hz (Pst = 1)

Relative illuminance

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5-400

-300

-200

-100

0

100

200

300

400

Time(sec)

Main

s v

oltage (

V)

EUT1

17

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.50.6

0.7

0.8

0.9

1

1.1

1.2

1.3

Time (sec)

Rela

tive illu

min

ance

EUT2

May 23, 2014 Philips Innovation Services

Page 18: Objective testing of flicker and stroboscopic effects resulting from

100

101

0

0.2

0.4

0.6

0.8

1

Frequency(Hz)

Pst

(pu)

Results voltage fluctuation immunity tests

Pst=1

EUT1

EUT2

EUT3

Example test voltage fluctuation (2) Results for 3 EUTs @ all test points

18

EUT1: 60 W incandescent lamp EUT2: 9 W self-ballasted CFL lamp EUT3: 7 W self-ballasted LED lamp

May 23, 2014 Philips Innovation Services

Page 19: Objective testing of flicker and stroboscopic effects resulting from

Summary

19

• Flicker and stroboscopic effect are important light quality aspects for lighting equipment

• There is an increasing diversity of flicker sensitivity of lighting equipment

• New lighting technologies drive – EMC and performance standards to include requirements for flicker and/or

stroboscopic effects – Need for an immunity test method, metrics and limits

• An objective way of flicker and strobo testing is developed, capable of – Applying a variety of test voltages – Analyzing illuminance waveforms using a variety of metrics

May 23, 2014 Philips Innovation Services

Page 20: Objective testing of flicker and stroboscopic effects resulting from

20 May 23, 2014 Philips Innovation Services

Further reading

• M. Perz et al, Modeling the visibility of the stroboscopic effect occurring in temporally modulated light systems, Lighting Research and Technology, May 13, 2014 : http://lrt.sagepub.com/content/early/2014/05/12/1477153514534945.full.pdf?ijkey=GcQ3UW7Qz2UwqtM&keytype=ref

• US DoE – Solid-state lighting technology fact sheet:

http://apps1.eere.energy.gov/buildings/publications/pdfs/ssl/flicker_fact-sheet.pdf

Page 21: Objective testing of flicker and stroboscopic effects resulting from

21 May 23, 2014 Philips Innovation Services

Acknowledgement

This work is supported by the Eniac Joint Undertaking project Enlight: Energy efficient and intelligent lighting systems