9 8 7 6 5 4 2 1 3 A B C D E F G H J K FOUNDATION PLAN 2300 150 4583 4583 3708 3858 150 150 3230 3765 3765 3765 3730 4733 6460 (TYP) 2000 (TYP) 2000 (TYP) 4732 1860 7715 3230 7530 7345 2450 6330 4500 (TYP) 2000 (TYP) 7715 7530 3230 7530 7715 1860 4733 4733 6460 (TYP) 2000 (TYP) 3708 3858 3765 3765 3765 3765 3708 2300 6330 150 150 2000 (TYP) 2000 (TYP) 1800 1800 3165 3165 3165 3165 1200 1200 150 150 3858 150 7565 150 7530 3230 7530 7565 2160 4583 4583 150 7495 7530 3230 7565 2160 4583 4583 150 3858 9 8 7 6 5 4 2 1 3 A B C D E F G H J K 4733 4733 1860 7715 3230 7530 7345 2450 6330 7715 7530 3230 7530 7715 1860 4733 185 35 35 4733 185 185 PB (230x300) 185 PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300) (TYP) PB (230x300) (TYP) 9 8 7 6 5 4 2 1 3 A B C D E F G H J K 4733 4733 1860 7715 3230 7530 7345 2450 6330 7715 7530 3230 7530 7715 1860 4733 185 35 35 4733 185 185 185 RB (230x600) RB (230x800) RB (230x900) RB (230x300) RB (230x400) (TYP) RB (230x400) (TYP) 9 8 7 6 5 4 2 1 3 A B C D E F G H J K 4733 4733 1860 7715 3230 7530 7345 2450 6330 7715 7530 3230 7530 7715 1860 4733 185 35 35 4733 185 185 185 LB (230x350) LB (230x300) LB (230x300) (TYP) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) 185 185 LB (230x350) LB (230x350) LB (230x300) (TYP) PLAN AT PLINTH LEVEL PLAN AT ROOF SLAB (+3.750m,+7.50m,+11.250m) PLAN AT LINTEL LEVEL SUNSHADE LINE SUNSHADE LINE SUNSHADE LINE SUNSHADE LINE GL +3.75m +2.10m oN ''- +11.250m +9.60m 1800 450 150 150 1500 3230 UP UP A A B B SECTIONAL ELEVATION - AA (SOUTHERN WING) 3600 SOUTHERN WING WESTERN WING 1800 RB (230x800) RB (230x800) RB (230x800) RB (230x800) RB (230x800) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x600) RB (230x900) RB (230x300) RB (230x900) RB (230x300) RB (230x900) RB (230x300) RB (230x900) RB (230x300) RB (230x900) RB (230x300) RB (230x900) RB (230x300) RB (230x900) RB (230x300) RB (230x900) RB (230x300) RB (230x300) RB (230x300) RB (230x900) RB (230x900) RB (230x300) RB (230x600) RB (230x600) RB (230x300) RB (230x900) RB (230x800) RB (230x300) RB (230x600) RB (230x900) RB (230x800) RB (230x300) RB (230x600) RB (230x900) RB (230x800) RB (230x300) RB (230x600) RB (230x900) RB (230x800) RB (230x300) RB (230x600) RB (230x900) RB (230x800) RB (230x300) RB (230x600) RB (230x900) RB (230x800) RB (230x300) RB (230x600) RB (230x900) RB (230x800) RB (230x300) RB (230x600) RB (230x900) RB (230x800) RB (230x600) RB (230x300) RB (230x600) RB (230x300) RB (230x900) GL +3.75m +2.10m oN ''- 150 150 1500 SECTIONAL ELEVATION - BB (WESTERN WING) 300 300 400 300 400 PB LB EB LB EB 300 300 400 300 400 LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x350) LB (230x300) C C D D C C D D PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB PB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB 400 LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB LB EB +7.50m +5.85m 4733 A A B B A A B B A A B B C C C C E E E E C C C C E E C C C C E E C C C C E E E E E E E E +11.250m +9.60m +7.50m +5.85m SUNSHADE LINE SUNSHADE LINE SUNSHADE LINE RB (230x600) @+3.75M,7.5M ONLY 1400 SECTION - DD 2000 120 3750 3750 FFL 0.00M GL 2100 1500 800 2100 (SCALE 1:50) COLUMN (300x600) PLINTH BEAM (230x300) PLINTH BEAM (230x300) PLINTH BEAM (230x300) ROOF BEAM (230x900) LINTEL BEAM (230x300) LINTEL BEAM (230x350) LINTEL BEAM (230x350) ROOF BEAM (230x300) LINTEL BEAM (230x300) ROOF BEAM (230x300) EDGE BEAM (230x400) ROOF BEAM (230x900) ROOF BEAM (230x800) LINTEL BEAM (230x350) LINTEL BEAM (230x350) ROOF BEAM (230x800) 11250 75THK WEATHERING COURSE WITH FLAT TILE FINISH EDGE BEAM (230x400) COLUMN (300x600) COLUMN (300x300) ROOF BEAM (230x600) ROOF BEAM (230x600) 200 800 SECTION - CC 2000 120 3749 3750 FFL 0.00M GL 2099 1500 800 2100 (SCALE 1:50) COLUMN (300x600) PLINTH BEAM (230x300) PLINTH BEAM (230x300) ROOF BEAM (230x900) LINTEL BEAM (230x300) LINTEL BEAM (230x350) ROOF BEAM (230x300) LINTEL BEAM (230x300) ROOF BEAM (230x300) EDGE BEAM (230x400) COLUMN (300x600) ROOF BEAM (230x900) 11249 EDGE BEAM (230x400) COLUMN (300x300) 2101 450 200 800 ROOF BEAM (230x900) ROOF BEAM (230x900) LINTEL BEAM (230x350) LINTEL BEAM (230x300) LANDING BEAM (230x450) 2100 +1.950 LANDING BEAM (230x450) +4.260 +5.700 +14.150 14149 +8.010 600 600 LB EB LB EB PLINTH BEAM LANDING BEAM LINTEL BEAM LANDING BEAM SECTION - EE (SCALE 1:50) E E 300 450 350 450 350 450 350 GL 400 300 400 300 +7.500 +5.700 +4.260 +1.950 +2.400 +3.350 +7.100 +3.750 +6.150 +8.010 PB ELEVATION AT STAIRCASE 500 150 200 LINTEL BEAM GL 2800 800 FFL 0.00M 2000 2800 120 3750 2100 ROOF BEAM (230x900) LINTEL BEAM (230x300) LINTEL BEAM (230x350) ROOF BEAM (230x300) ROOF BEAM (230x800) LINTEL BEAM (230x350) EDGE BEAM (230x400) ROOF BEAM (230x600) ROOF BEAM (230x300) LINTEL BEAM (230x300) ROOF BEAM (230x300) EDGE BEAM (230x400) ROOF BEAM (230x900) ROOF BEAM (230x900) LINTEL BEAM (230x350) LANDING BEAM (230x450) 600 350 +9.450 +11.760 3750 2100 LB EB LANDING BEAM 450 350 400 300 +11.25 +9.450 +10.85 +9.90 +11.760 LINTEL BEAM E9 500 ROOF BEAM (230x500) ROOF BEAM (230x500) ROOF BEAM (230x500) +14.150 ROOF BEAM 500 K4 F9 K3 LB EB LB EB LB EB FFL 0.00M -0.700M FFL 0.00M -0.700M 100 0-TP-CEG-01775 N.KAVITHA K.GUNASEKARAN 24.02.2015 24.02.2015 24.02.2015 CORPORATE SOCIAL SOCIAL RESPONSIBILITY (CSR) BHEL MATRICULATION HIGHER SECONDARY SCHOOL NOTES:- 1) ALL DIMENSIONS ARE IN 'MM' &LEVELS ARE IN 'M'. 2) DO NOT SCALE THE DRAWING. FOLLOW WRITTEN DIMENSION ONLY. 3) CONCRETE GRADE M20. 4) FOUNDATION IS DESIGNED FOR G+2 STOREYS ONLY. 5) FOR GENERAL ARRANGEMENT DETAILS REFER DRAWING NO. 0-TP-CEG-01678 6) FOR DETAILS OF REINFORCEMENT REFER SEPERATE DRAWING. LEGEND: PB - PLINTH BEAM LB - LINTEL BEAM RB - ROOF BEAM R.C.C FRAME DETAILS FOR PROPOSED CLASSROOMS IN SCHOOL EB - EDGE BEAM FOR TENDER PURPOSE ONLY

o N ''-TYP) EWC D2-0.025 IWC 1240(TYP) IWC D2-0.025 1495 U D1 D1 STAFF TOILET V V VEFV BOYS TOILET URINAL AREA V V V 6100 BB 3600 STUB COLUMN STUB COLUMN STUB COLUMN CLASS ROOM CLASS

Embed Size (px)

Citation preview

98765421 3

A

B

C

D

E

F

G

H

J

K

FOUNDATION PLAN

2300

150

4583

4583

3708

3858

150

150

3230

3765

3765

3765

3730

4733

6460

(TYP

)

2000(TYP)

2000(TYP)

4732

1860

7715

3230

7530

7345

2450

6330

4500(TYP)

2000

(TYP

)

7715 7530 3230 7530 7715 1860 4733 4733

6460(TYP)

2000

(TYP

)

3708 3858 3765 3765 3765 3765 3708

2300

6330

150

150

2000

(TYP

)20

00(T

YP)

1800

1800

3165

3165

3165 3165

1200

1200 150 150

3858

150 7565

150

7530 3230 7530 7565 2160 4583 4583

150

7495

7530

3230

7565

2160

4583

4583

150

3858

98765421 3

A

B

C

D

E

F

G

H

J

K

4733

4733

1860

7715

3230

7530

7345

2450

6330

7715 7530 3230 7530 7715 1860 4733

185

3535

4733185185

PB (230x300)

185

PB (230x300)

PB (230x300)

PB (230x300)

PB (230x300)

PB (230x300)

PB (230x300)

PB (230x300)

PB (230x300)

PB (23

0x30

0)PB

(23

0x30

0)PB

(23

0x30

0)

PB (23

0x30

0)PB

(23

0x30

0)

PB (23

0x30

0)

PB (23

0x30

0)

PB (23

0x30

0)

PB (23

0x30

0)

PB (23

0x30

0)

PB (23

0x30

0)

PB (23

0x30

0)

PB (23

0x30

0)

PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300)

PB (230x300) PB (230x300) PB (230x300) PB (230x300) PB (230x300)

PB (23

0x30

0)

PB (230x300) (TYP)

PB (23

0x30

0) (TY

P)

98765421 3

A

B

C

D

E

F

G

H

J

K

4733

4733

1860

7715

3230

7530

7345

2450

6330

7715 7530 3230 7530 7715 1860 4733

185

3535

4733 185185

185

RB (23

0x60

0)

RB (230x800)

RB (230x900)

RB(230

x300

)

RB (230x400) (TYP)

RB (23

0x40

0) (TY

P)

98765421 3

A

B

C

D

E

F

G

H

J

K

4733

4733

1860

7715

3230

7530

7345

2450

6330

7715 7530 3230 7530 7715 1860 4733

185

3535

4733185185

185

LB (230x350)

LB (23

0x30

0)

LB (230x300) (TYP)

LB (230x350)

LB (230x350)

LB (230x350)

LB (230x350)

LB (230x350)

LB (230x350)

LB (230x350)

LB (230x350)

LB (230x350)

185 185

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x30

0) (TY

P)

PLAN AT PLINTH LEVELPLAN AT ROOF SLAB (+3.750m,+7.50m,+11.250m)

PLAN AT LINTEL LEVEL

SUNSHADE LINE

SUNSHADE LINE SUNSHADE LINE SUNSHADE LINE

GL

+3.75m

+2.10m

±0.00m FFL

+11.250m

+9.60m

1800

450

150

150

1500

3230

UP

UP

AA

B

B

SECTIONAL ELEVATION - AA (SOUTHERN WING)

3600

SOUTHERN WING

WES

TERN

WING

1800

RB (230x800) RB (230x800) RB (230x800) RB (230x800) RB (230x800)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (23

0x60

0)

RB (230x900)

RB(230

x300

)

RB (230x900)

RB(230

x300

)

RB (230x900)

RB(230

x300

)

RB (230x900)

RB(230

x300

)

RB (230x900)

RB(230

x300

)

RB (230x900)

RB(230

x300

)

RB (230x900)

RB(230

x300

)

RB (230x900)

RB(230

x300

)

RB(230

x300

)

RB(230

x300

)

RB (230x900)

RB (230x900)

RB(230x300) RB (230x600)

RB (230x600)

RB(230

x300

)

RB (23

0x90

0)

RB (23

0x80

0)

RB(230x300) RB (230x600)RB

(23

0x90

0)

RB (23

0x80

0)

RB(230x300) RB (230x600)RB

(23

0x90

0)

RB (23

0x80

0)

RB(230x300) RB (230x600)RB

(23

0x90

0)

RB (23

0x80

0)

RB(230x300) RB (230x600)RB

(23

0x90

0)

RB (23

0x80

0)

RB(230x300) RB (230x600)RB

(23

0x90

0)

RB (23

0x80

0)

RB(230x300) RB (230x600)RB

(23

0x90

0)

RB (23

0x80

0)

RB(230x300) RB (230x600)RB

(23

0x90

0)

RB (23

0x80

0)

RB (230x600)

RB(230x300)

RB (230x600)

RB(230x300) RB

(23

0x90

0)

GL

+3.75m

+2.10m

±0.00m FFL

150

150

1500

SECTIONAL ELEVATION - BB (WESTERN WING)

300

300

400

300

400

PB

LB

EB

LB

EB

300

300

400

300

400

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB (23

0x35

0)

LB(230x300)

C

C

D

D

C

C

D

D

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

PB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

400

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB

LB

EB+7.50m

+5.85m

4733

AA

B

B

AA

B

B

AA

B

B

C

C

CC

EE

E

E

C

C

CC

E

E

C

C

CC

E

E

C

C

CC

E

E

E E

E E

E E

+11.250m

+9.60m

+7.50m

+5.85m

SUNSHADE LINE

SUNSHADE LINE

SUNSHADE LINE

RB (23

0x60

0)@+3

.75M

,7.5M

ONLY

1400

SECTION - DD

2000

120

3750

3750

FFL 0.00M

GL

2100

1500

800

2100

(SCALE 1:50)

COLUMN(300x600)

PLINTH BEAM(230x300)PLINTH BEAM

(230x300)PLINTH BEAM

(230x300)

ROOF BEAM(230x900)

LINTEL BEAM(230x300)

LINTEL BEAM(230x350)

LINTEL BEAM(230x350)

ROOF BEAM(230x300)

LINTEL BEAM(230x300)

ROOF BEAM(230x300)

EDGE BEAM(230x400)

ROOF BEAM(230x900)

ROOF BEAM(230x800)

LINTEL BEAM(230x350)

LINTEL BEAM(230x350)

ROOF BEAM(230x800)

1125

0

75THK WEATHERING COURSEWITH FLAT TILE FINISH

EDGE BEAM(230x400)

COLUMN(300x600)

COLUMN(300x300)

ROOF BEAM(230x600)

ROOF BEAM(230x600)

200

800

SECTION - CC

2000

120

3749

3750

FFL 0.00M

GL

2099

1500

800

2100

(SCALE 1:50)

COLUMN(300x600)

PLINTH BEAM(230x300)

PLINTH BEAM(230x300)

ROOF BEAM(230x900)

LINTEL BEAM(230x300) LINTEL BEAM

(230x350)

ROOF BEAM(230x300)

LINTEL BEAM(230x300)

ROOF BEAM(230x300)

EDGE BEAM(230x400)

COLUMN(300x600)

ROOF BEAM(230x900)

1124

9

EDGE BEAM(230x400)

COLUMN(300x300)

2101

450

200

800

ROOF BEAM(230x900)

ROOF BEAM(230x900)

LINTEL BEAM(230x350)

LINTEL BEAM(230x300)

LANDING BEAM(230x450)

2100

+1.950

LANDING BEAM(230x450)

+4.260

+5.700

+14.150

1414

9

+8.010

600

600

LB

EB

LB

EB

PLINTH BEAM

LANDING BEAM

LINTEL BEAM

LANDING BEAM

SECTION - EE(SCALE 1:50)

E

E

300

450

350

450

350

450

350

GL

400

300

400

300

+7.500

+5.700

+4.260

+1.950

+2.400

+3.350

+7.100

+3.750

+6.150

+8.010

PB

ELEVATION AT STAIRCASE

500

150200

LINTEL BEAM

GL

2800

800

FFL 0.00M

2000 2800

120

3750

2100

ROOF BEAM(230x900)

LINTEL BEAM(230x300) LINTEL BEAM

(230x350)

ROOF BEAM(230x300)

ROOF BEAM(230x800)

LINTEL BEAM(230x350)

EDGE BEAM(230x400)

ROOF BEAM(230x600)

ROOF BEAM(230x300)

LINTEL BEAM(230x300)

ROOF BEAM(230x300)

EDGE BEAM(230x400)

ROOF BEAM(230x900)

ROOF BEAM(230x900)

LINTEL BEAM(230x350)

LANDING BEAM(230x450)

600

350

+9.450

+11.760

3750

2100

LB

EB

LANDING BEAM 450

350

400

300

+11.25

+9.450

+10.85

+9.90

+11.760

LINTEL BEAM

E9

500

ROOF BEAM(230x500)

ROOF BEAM(230x500)

ROOF BEAM(230x500)

+14.150

ROOF BEAM500

K4F9K3

LB

EB

LB

EB

LB

EB

FFL 0.00M

-0.700M

FFL 0.00M

-0.700M

100

0-TP-CEG-01775

N.KAVITHA

K.GUNASEKARAN

24.02.2015

24.02.2015

24.02.2015

CORPORATE SOCIAL SOCIAL RESPONSIBILITY (CSR)

BHEL MATRICULATION HIGHER SECONDARY SCHOOL

NOTES:-1) ALL DIMENSIONS ARE IN 'MM' &LEVELS ARE IN 'M'.2) DO NOT SCALE THE DRAWING. FOLLOW WRITTEN DIMENSION ONLY.3) CONCRETE GRADE M20.4) FOUNDATION IS DESIGNED FOR G+2 STOREYS ONLY.5) FOR GENERAL ARRANGEMENT DETAILS REFER DRAWING NO. 0-TP-CEG-016786) FOR DETAILS OF REINFORCEMENT REFER SEPERATE DRAWING.

LEGEND:

PB - PLINTH BEAMLB - LINTEL BEAMRB - ROOF BEAM

R.C.C FRAME DETAILS FOR PROPOSEDCLASSROOMS IN SCHOOL

EB - EDGE BEAM

FOR TENDER PURPOSE ONLY

98765421 3

A

B

C

D

E

F

G

H

J

K

4733

4733

1860

7715

3230

7530

7345

2450

6330

7715 7530 3230 7530 7715 1860 4733

185

3535

4733185185

185

GROUND FLOOR PLAN

UP

UP

185185

STUBCOLUMN

W

3600 6100

D

3600

D

3600

D

BB3600

D

JW W W W W W W W W W W

V

EF

WB

D2D2

D2

IWC

IWC

-0.025

-0.025

-0.025

1100

(TYP

)

EWC

D2

-0.025

IWC

1240

(TYP

)

D2IWC

-0.025

1495UUUUU U U U

D1 D1STAFF TOILET

VV EF VV

BOYS TOILET

URINAL

ARE

A

VV

V

6100

BB

3600

STUBCOLUMN

STUBCOLUMN

STUBCOLUMN

CLASS ROOMCLASS ROOM CLASS ROOM CLASS ROOM

CLASS ROOM

WW

W

D

BBBBBB

BB

3600

WW

W

D

BB

3600

WW

W

D

CLASS ROOM

CLASS ROOM

V

WB

D2D2D2

IWC

IWC

-0.025

-0.025

-0.025

1100(TYP)

EWC

D2

-0.025

IWC

1240(TYP)

D2

IWC

-0.025

D1

V

GIRLS TOILET

V V V

D1

EFV

VEF

V

D2 D2

IWC

IWC

D2

IWC

IWC

D2

WT

3000

D2

98765421 3

A

B

C

D

E

F

G

H

J

K

4733

4733

1860

7715

3230

7530

7345

2450

6330

7715 7530 3230 7530 7715 1860 4733

185

3535

4733185185

185

FIRST & SECOND FLOOR PLAN

UP

UP

185185W

3600 6100

D

3600

D36

00D

BB3600

D

JW W W W W W W W W W W

V

EF

WB

D2D2

D2

IWC

IWC

-0.025

-0.025

-0.025

1100

(TYP

)

EWC

D2

-0.025

IWC

1240

(TYP

)

D2IWC

-0.025

1495UUUUU U U U

D1 D1STAFF TOILET

VV EF VV

BOYS TOILET

URINAL

ARE

A

VV

V

6100

BB

3600

CLASS ROOMCLASS ROOM CLASS ROOM CLASS ROOM

CLASS ROOM

WW

W

D

BBBBBB

BB

3600

WW

W

D

BB

3600

WW

W

D

CLASS ROOM

CLASS ROOM

V

WB

D2D2D2

IWC

IWC

-0.025

-0.025

-0.025

1100(TYP)

EWC

D2

-0.025

IWC

1240(TYP)

D2

IWC

-0.025

D1

V

GIRLS TOILET

V V V

D1

EFV

VEF

V

D2 D2

IWC

IWC

D2

IWC

IWC

D2

WT

3000

D2

33580 2000 9325

34610

2000

9325

8790

3714

5

36115

8790

230

UP

UP

D3

D3

1000

SLOP

E

SLOP

E

SLOP

E

SLOPE

SLOPE

1000

SOUTHERN WING

WESTERN WING

110 ∅ PVC RWP

TERRACE PLAN

PARAPETWALL

ELEVATION - SOUTHERN WING (VIEW-AA)GL GL

ELEVATION - WESTERN WING (VIEW-BB)

A

B

B

C

C

C C

D

D

D D

A

A

B

B

C

C

C C

D

D

D D

1050

650

550

100

SAND FILLINGSUNKEN SLAB 120.THK

480

SAND FILLINGSUNKEN SLAB 120.THK

480

SUNSHADE LINE

SUNSHADE LINE

SUNSHADE LINE

J

SUNSHADE LINE

SUNSHADE LINE

SUNSHADE LINE SUNSHADE LINE

SUNSHADE LINE

AMAINCOLUMN

MAINCOLUMN

MAINCOLUMN

MAINCOLUMN

MAINCOLUMN

MAIN COLUMN

MAIN COLUMN

MAIN COLUMN

SLOP

E

SLOP

E

SLOP

E

SLOP

E

SLOP

E

SLOPE

SLOPE

SLOPE

SLOPE

SLOPE

1515TYP

1515

TYP

1515

TYP

TYPICAL DETAIL OF STAIRCASE

RISER 150MM

TREAD 300MM

150MM R

.C.C WAIST

SLAB

(SCALE 1:50)

BRICK WORK C.M 1:5

900

1500

600

3000

(SCALE 1:20)

PERCOLATION PIT DETAILS FOR RAIN WATERHARVESTING

300

G.L

SAND FILLING

JELLY

PEBBLES

PRECAST RCC SLAB (PERFORATED)

10025

P.C.C 1:4:8SAND FILLING

25THK ELLIS PATTERN FLOOR

100

DETAILS OF FLOORING(SCALE 1:20)

150

7560

DETAILS OF LINTEL CUM SUNSHADEOVER HEADROOM DOOR OPENING

3-12

8 STPS @ 150C/C

2-10

8 @ 150 c/c

8 @ 200 c/c

230600

O

O

O

O

O

10 -3NOS

8 -2NOS

8 -2L-STPS @150C/C

DETAILS OF LINTEL OVER VENTILATOR

230

150

O

O

O

2000

120

3750

12

34

56

78

910

1112

1314

1516

171819

202122

2324

25

1570

2100

1225

0

1100

1000

230

+5.70

150

2000

120

3750

2627

2829

3031

3233

3435 36

373839

4041

424344

454647

4849

50

1570

2100

1100

1000

230

+14.150

150

FFL 0.00M

P.C.C 1:4:8

BRICK WORK INCM 1:5

GLGL

930

STUB COLUMN

1800 1200 1900150

800

1500PLINTH BEAM

800

2000 100

450

+8.01

+4.26

150

500

200

150

1000

1100

+9.45

2000

120

5152

5354

5556

5758

5960 61

626364

6566

676869

707172

7374

75

1570

230

150

+11.76

3750

2100

1000

1000

75 THK WEATHERING COURSEWITH FLAT TILE FINISH

+1.95

DWARF WALL

PLINTH BEAM

SECTION - CC(SCALE 1:50)

700

2000

120

3750

FFL 0.00M

2100

DWARF WALL

GL GL

1000

300

1200

230

1000

PLINTH BEAM

2000

120

3750

2100

1000

1125

0

PARAPET WALL

1000

1200

230

75 THK WEATHERING COURSEWITH FLAT TILE FINISH

1800

P.C.C 1:4:8

450

PLINTH BEAM

2000

800

STUB COLUMN

1200

250

2000

150

1500

100

800

2000

3750

2100

1000

1200

230

110 ∅ PVCRWP

SECTION - DD(SCALE 1:50)

PLINTH BEAM 100

0-TP-CEG-016780

0

0-TP-CEG-01678

N.KAVITHA

K.GUNASEKARAN

24.02.2015

24.02.2015

24.02.2015

NOTES:-

1) ALL DIMENSIONS ARE IN 'MM' &LEVELS ARE IN 'M'.2) DO NOT SCALE THE DRAWING. FOLLOW WRITTEN DIMENSION ONLY.3) CONCRETE GRADE M20.4) FOUNDATION IS DESIGNED FOR G+2 STOREYS ONLY5) FOR RCC DETAILS REFER DRAWING NO: 0-TP-CEG-01775.

LEGEND:-D - COUNTRY WOOD PANELLED DOOR 2000 X 2100.D1 - PVC PANELLED DOOR 1000 X 2100.D2 - PVC PANELLED DOOR 750 X 2100.

TOTAL AREA - 695.00 SQM.

AREA OF STAIRCASE - 44.00 SQM.

AREA OF PROPOSED SCHOOL BUILDING - 651.00 SQM.

CORPORATE SOCIAL SOCIAL RESPONSIBILITY (CSR)

BHEL MATRICULATION HIGHER SECONDARY SCHOOL

GENERAL ARRANGEMENT OF PROPOSEDCLASSROOMS IN SCHOOL

TOTAL AREA - 695.00 SQM.

AREA OF STAIRCASE - 44.00 SQM.

AREA OF PROPOSED SCHOOL BUILDING - 651.00 SQM.

TOTAL AREA - 695.00 SQM.

AREA OF STAIRCASE - 44.00 SQM.

AREA OF PROPOSED SCHOOL BUILDING - 651.00 SQM.

GROUND FLOOR

FIRST FLOOR

SECOND FLOOR

W - GLAZED ALUMINIUM SLIDING WINDOW WITH ALUMINIUM GRILL - 1200 X 1200.V - GLAZED ALUMINIUM LOUVERED VENTILATOR - 600 X 600.EF - EXHAUST FAN DIA 600MM.IWC - INDIAN WATER CLOSETEWC - EUROPEAN WATER CLOSETWT - WASH TROUGHBB - BLACK BOARDWB - WASH BASINJ - RCC JALLY 1000x1060

D3 - COUNTRY WOOD PANELLED DOOR 1000 X 2100.

RWP - RAIN WATER PIPE

FOR TENDER PURPOSE ONLY