NUREG-1843 Supplement 1 ,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and 3 Docket Nos. 50-259, 50-260, and 50-296 Tennessee Valley Authority U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Ad Washington, DC 20555-0001

NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

NUREG-1843Supplement 1

,I

Safety Evaluation ReportRelated to the License Renewal ofthe Browns Ferry Nuclear Plant,Units 1, 2, and 3

Docket Nos. 50-259, 50-260, and 50-296

Tennessee Valley Authority

U.S. Nuclear Regulatory CommissionOffice of Nuclear Reactor Regulation AdWashington, DC 20555-0001

Page 2: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

AVAILABILITY OF REFERENCE MATERIALSIN NRC PUBLICATIONS

NRC Reference Material

As of November 1999, you may electronically accessNUREG-series publications and other NRC records atNRC's Public Electronic Reading Room athtto:llwww.nrc.pov/readinp-rm.html.Publicly released records include, to name a few,NUREG-series publications; Federal Register notices;applicant, licensee, and vendor documents andcorrespondence; NRC correspondence and Internalmemoranda; bulletins and information notices;inspection and Investigative reports; licensee eventreports; and Commission papers and theirattachments.

NRC publications in the NUREG series, NRCregulations, and Title 10, Energy, In the Code ofFederal Regulations may also be purchased from oneof these two sources.1. The Superintendent of Documents

U.S. Government Printing OfficeMail Stop SSOPWashington, DC 20402-0001Intemet: bookstore.gpo.govTelephone: 202-512-1800Fax: 202-512-2250

2. The National Technical Information ServiceSpringfield, VA 22161-0002www.ntis.gov1-800-553-6847 or, locally, 703-605-6000

A single copy of each NRC draft report for comment Isavailable free, to the extent of supply, upon writtenrequest as follows:Address: Office of the Chief Information Officer,

Reproduction and DistributionServices Section

U.S. Nuclear Regulatory CommissionWashington, DC 20555-0001

E-mail: DlSTRIBUTION~nrc.govFacsimile: 301-415-2289

Some publications in the NUREG series that areposted at NRC's Web site addresshtto:lfwww.nrc.aov/readina-rm/doc-collectionslnureas

Non-NRC Reference Material

Documents available from public and special technicallibraries include all open literature items, such asbooks, Journal articles, and transactions, FederalRegister notices, Federal and State legislation, andcongressional reports. Such documents as theses,dissertations, foreign reports and translations, andnon-NRC conference proceedings may be purchasedfrom their sponsoring organization.

Copies of Industry codes and standards used In asubstantive manner In the NRC regulatory process aremaintained at-

The NRC Technical LibraryTwo White Flint North11545 Rockville PikeRockville, MD 20852-2738

These standards are available In the library forreference use by the public. Codes and standards areusually copyrighted and may be purchased from theoriginating organization or, if they are AmericanNational Standards, from-

American National Standards Institute11 West 42Id StreetNew York, NY 10036-8002www.ansi.org212-642-4900

Legally binding regulatory requirements are statedonly In laws; NRC regulations; licenses, includingtechnical specifications; or orders, not inNUREG-series publications. The views expressedIn contractor-prepared publications In this seriesare not necessarily those of the NRC.

The NUREG series comprises (1) technical andadministrative reports and books prepared by thestaff (NUREG-X)00) or agency contractors(NUREG/CR-X)X(X), (2) proceedings ofconferences (NUREGICP-XXXX), (3) reportsresulting from International agreements(NUREGIIA-XX)OO), (4) brochures(NUREGlBR-XOOO, and (5) compilations of legaldecisions and orders of the Commission andAtomic and Safety Licensing Boards and ofDirectors' decisions under Section 2.206 of NRC'sregulations (NUREG-0750).

are updated periodically and may differ from the lastprinted version. Although references to material foundon a Web site bear the date the material wasaccessed, the material available on the date cited maysubsequently be removed from the site.

Page 3: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

NUREG-1843Supplement 1

Safety Evaluation ReportRelated to the License Renewal ofthe Browns Ferry Nuclear Plant,Units 1, 2, and 3

Docket Nos. 50-259, 50-260, and 50-296

Tennessee Valley AuthorityManuscript Completed: April 2006Date Published: April 2006

Prepared byY. Diaz-Sanabiia and R Subbaratnam

Division of License RenewalOffice of Nuclear Reactor RegulationU.S. Nuclear Regulatory CommissionWashington, DIC 20555-0001

Page 4: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and
Page 5: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

ABSTRACT

This document is a supplemental safety evaluation report (SSER) on the application for licenserenewal for the Browns Ferry Nuclear Plant (BFN), as filed by Tennessee Valley Authority (TVAor the applicant). By letter dated December 31, 2003, TVA submitted its application to the U.',.Nuclear Regulatory Commission (NRC or the Commission) for renewal of the BFN operatinglicenses for an additional 20 years. The NRC staff (the staff) issued a safety evaluation report(SER), dated January 12, 2006, which summarizes the results of its safety review of therenewal application for compliance with the requirements of Title 10, Part 54, of the Code ofFederal Regulations, (10 CFR Part 54), "Requirements for Renewal of Operating Licenses forNuclear Power Plants."

During the 530t full committee meeting of the Advisory Committee on Reactor Safeguards,March 9, 2006, the Committee reviewed the license renewal application (LRA) for BFN Units 1,2, and 3. The staff had closed the open items with a commitment to issue a supplementalsafety evaluation report (SSER) that addresses the Committee's review comments on the SER.This SSER addresses the Committee's concerns and includes revisions and enhancements tDthe following aging management programs (AMPs): (1) Unit 1 Periodic Inspection Program(B.2.1.42), (2) ASME Section Xl Subsection IWE Program (B.2.1.32), and (3) Open-CycleCooling Water System Program (B.2.1.17). This supplement also addresses the Committee'sother concerns as documented in its final letter report dated March 23, 2006.

iii

Page 6: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and
Page 7: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE OF CONTENTS'

Abstract .................................................................. iii

Table of Contents ........................................................... v

Abbreviations ............................................................. vi

1 Introduction and General Discussion ......................................... 1-1

3 Aging Management Review Results ......................................... 3-13.0.3 Aging Management Programs ............ .. .................. 3-1

3.0.3.2 AMPs That Are Consistent with the GALL Report withExceptions or Enhancements ......................... 3-1

3.0.3.3 AMPs That Are Not Consistent with or Not Addressed in theGALL Report ..................................... 3-7

3.3 Aging Management of Auxiliary Systems ............................. 3-143.3.2.3 AMR Results That Are Not Consistent with or Not Addressed

in the GALL Report ............................... 3-143.5 Aging Management of Containments, Structures, and Components Supports . 3-16

3.5.2.3 AMR Results That Are Not Consistent with or Not Addressedin the GALL Report ................................ 3-16

3.5.3 Conclusion ............................................. 3-183.8 Conclusion for Aging Management .................................. 3-18

5 Review by the Advisory Committee on Reactor Safeguards ......... .............. 5-1

6 Conclusions ........................................................... 6-1

Appendix A: Commitments for License Renewals ................................ A-1

Appendix B: Chronology ............... .................................... B-1

Appendix C: Principal Contributors ............................................. C-1

The numbering of the sections listed in this NUREG supplement is based on thenumbering of the corresponding chapters and sections in NUREG-1843.

v

Page 8: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

ABBREVIATIONS

ACI American Concrete InstituteACRS Advisory Committee on Reactor SafeguardsAHC access hole coverAMP aging management programAMR aging management reviewANSI American National Standards InstituteASME American Society of Mechanical EngineersASTM American Society for Testing and MaterialsATWS anticipated transient without scramBFN Browns Ferry Nuclear PlantBWR boiling water reactorBWRVIP Boiling Water Reactor Vessel and Internals ProjectCCW condensate circulating waterCFR Code of Federal RegulationsCLB current licensing basisCRD control rod driveEECW emergency equipment cooling waterEPRI Electric Power Research InstituteEPU extended power uprateEQ environmental qualificationFAC flow-accelerated corrosionFen environmental fatigue life correction factorFERC Federal Energy Regulatory CommissionGALL Generic Aging Lessons Learned ReportGL generic letterIGSCC intergranular stress corrosion crackingIRM intermediate range monitorISP Integrated Surveillance ProgramLPRM local power range monitorLRA license renewal applicationLTOP low temperature over-pressureMIC microbiologically influenced corrosionNDE nondestructive examinationNRC U.S. Nuclear Regulatory CommissionNUREG NRC technical report designation (Nuclear Regulatory Commission)OCCW open-cycle cooling waterRAI request for additional informationRHRSW residual heat removal service water

vi

Page 9: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

RPV reactor pressure vesselRPVII reactor pressure vessel internals inspectionRWCU reactor water cleanupSC structure and componentSER Safety Evaluation ReportSRP-LR Standard Review Plan for Review of License Renewal Applications for Nuclear

Power PlantsSRV safety relief valveSSC system, structure, and componentSSER supplemental safety evaluation reportTLAA time-limited aging analysisTS technical specificationTVA Tennessee Valley AuthorityUFSAR updated final safety analysis reportUT ultrasonic testing

vii

Page 10: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and
Page 11: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

SECTION 1

INTRODUCTION AND GENERAL DISCUSSION

This document is a supplemental safety evaluation report (SSER) on the application for licenserenewal for the Browns Ferry Nuclear Plant (BFN), as filed by Tennessee Valley Authority (IVAor the applicant). By letter dated December 31, 2003, TVA submitted its application to the U.S.Nuclear Regulatory Commission (NRC or the Commission) for renewal of the BFN operatinglicenses for an additional 20 years. The NRC staff (the staff) issued a safety evaluation report(SER), dated January 12, 2006, which summarizes the results of its safety review of therenewal application for compliance with the requirements of Title 10, Part 54, of the Code ofFederal Regulations, (10 CFR Part 54), "Requirements for Renewal of Operating Licenses forNuclear Power Plants."

During the 530' full committee meeting of the Advisory Committee on Reactor Safeguards,March 9, 2006, the Committee reviewed the license renewal application (LRA) for BFN Units. 1,2, and 3. The staff had closed the open items with a commitment to issue a supplementalsafety evaluation report (SSER) that addresses the Committee's review comments on the SEER.This SEER addresses the Committee's concerns and includes revisions and enhancements tothe following aging management programs (AMPs): (1) Unit 1 Periodic Inspection Program(B.2.1.42), (2) ASME Section Xl Subsection IWE Program (B.2.1.32), and (3) Open-CycleCooling Water System Program (B.2.1.17). This supplement also addresses the Committee'sother concerns as documented in its final letter report dated March 23, 2006.

1-1

Page 12: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

THIS PAGE IS INTENTIONALLY LEFT BLANK.

Page 13: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

SECTION 3

AGING MANAGEMENT REVIEW RESULTS

3.0.3 Aging Management Programs

3.0.3.2 AMPs That Are Consistent with the GALL Report with Exceptions orEnhancements

As supplemented in LRA Appendix B, the applicant identified that the following agingmanagement programs (AMPs) were, or will be, consistent with the GALL Report, withadditional enhancements:

* Open-Cycle Cooling Water System Program (B.2.1.17)

* ASME Section Xl Subsection IWE Program (B.2.1.32)

In its letter dated April 4, 2006, the applicant included additional supplemental information to theLRA for the above-mentioned programs that address the Advisory Committee on ReactorSafeguards (ACRS) concerns raised in the 530th full committee meeting, as documented byletter dated March 23, 2006.

3.0.3.2.11 Open-Cycle Cooling Water System Program

Summary of Technical Information in the ApDlication. The applicant's Open-Cycle CoolingWater (OCCW) System Program is described in LRA Section B.2.1.17, "Open-Cycle CoolingWater System Program." In the LRA, the applicant stated that this is an existing program. Thisprogram is consistent, with enhancement, with GALL AMP XL.M20, 'Open-Cycle Cooling WaterSystem.'

The OCCW System Program relies on implementation of the recommendations of GL 89-13 toensure that the effects of aging on the OCCW system will be managed for the extended periodof operation. The program includes surveillance and control techniques to manage agingeffects caused by biofouling, corrosion, erosion, protective coating failures, and silting in theOCCW system or structures and components serviced by the OCCW system.

During the 5301 full committee meeting of the ACRS, March 9, 2006, the committee reviewedthe LRA for BFN Units 1, 2, and 3. The staff had closed the open items with a commitment toissue a supplemental safety evaluation report (SSER) that would address an inspection concsrnon an open item on residual heat removal service water (RHRSW) system component, RHRS'Wpump pit suction pipe (see SSER Section 3.3.2.3.3). The aging management review (AMR) ofthis component required an enhancement to the OCCWS Program (see previous safetyevaluation report (SER), dated January 12, 2006, SER Section 3.0.3.2.11)

In resolving the issue, by letter dated April 4, 2006, the applicant stated the following:

In Enclosure 4 of a TVA letter to the NRC dated November 16, 2005 (ADAMS AccessionNo. ML053320331), TVA committed to perform a confirmatory inspection of the RHRS;W

3-1

Page 14: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

pump pit supply piping, sluice gate valves and seismic restraints in the RHRSW pumppit prior to the period of extended operation. As discussed with the ACRS on March 9,2006, BFN will perform an additional inspection within 10 years of entering the period ofextended operation.

These additional inspections require changes to the Open-Cycle Cooling Water SystemProgram described in LRA Sections A.1.16 and B.2.1.17.

The following is to be added to the end of LRA Section A.1.16:

In addition to the requirements of GL 89-13, the Open-Cycle Cooling WaterSystem Program will be enhanced to perform inspections on the internal portionof one of the embedded RHRSW pipes that run between the CCW Pump Pits tothe EECW / RHRSW Pump Pits, the RHRSW sluice gate valves located in theCCW pump pits, and the seismic restraints in the RHRSW pump pits. Theseinspections will be performed prior to the expiration of the current 40-yearlicense, and will be conducted at least one additional time within ten years ofentering the period of extended operation.

The following is being added to the LRA Section B.2.1.17 Enhancements:

In addition to the requirements of GL 89-13, the Open-Cycle Cooling WaterSystem Program will be enhanced to perform inspections on the internal portionof one of the embedded RHRSW pipes that run between the CCW Pump Pits tothe EECW / RHRSW Pump Pits, the RHRSW sluice gate valves located in theCCW pump pits, and the seismic restraints in the RHRSW pump pits. Theseinspections will be performed prior to the expiration of the current 40-yearlicense, and will be conducted at least one additional time within ten years ofentering the period of extended operation.

Program Elements Affected:

Element 5 - Monitoring and Trending

Inspection scope, method (e.g., visual or nondestructive examination [NDE]),and testing frequencies are in accordance with the utility commitments underNRC GL 89-13. Testing and inspections are done annually and during refuelingoutages. Inspections or nondestructive testing will determine the extent ofbiofouling, the condition of the surface coating, the magnitude of localized pitting,and the amount of MIC, if applicable. Heat transfer testing results aredocumented in plant test procedures and are trended and reviewed by theappropriate group.

BFN Evaluation

Element 5 requires that inspection scope, method (e.g., visual or nondestructiveexamination [NDE]), and testing frequencies are in accordance with the utilitycommitments under NRC GL 89-13. The inspections associated with thisenhancement are in addition to the BFN commitments under NRC GL 89-13.

3-2

Page 15: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

These inspections will provide additional assurance that there is no loss ofintended function of the Open-Cycle Cooling Water System.

By letter dated November 16, 2005, the applicant committed to perform a confirmatoryinspection of the RHRSW pump pit supply piping, sluice gate valves, and seismic restraints i:1the RHRSW pump pit prior to the period of extended operation. As discussed with the ACRS onMarch 9, 2006, the applicant will perform an additional inspection within 10 years of entering theperiod of extended operation.

Staff Evaluation. The staff agrees with the applicant's evaluation and concludes that with theproposed enhancement, the staff found the OCCW System Program is consistent with GALL.AMP Xl.M20 and, therefore, acceptable. These additional inspections require changes to theOCCW System Program described in LRA Sections A.1.16 and B.2.1.17. This also closed theopen item from the AMP inspection.

UFSAR SupDlement. In LRA Section A.1.16, the applicant provided the UFSAR supplement forthe OCCW System Program. The staff reviewed this section and determined that theinformation, with the above revision to the UFSAR supplement provides an adequate summarydescription of the program. The staff found that this section of the UFSAR supplement, withrevision, met the requirements of 10 CFR 54.21(d).

Conclusion. On the basis of its review and audit of the applicant's program, the staff determinedthat those program elements for which the applicant claimed consistency with the GALL Reportare consistent with the GALL Report. In addition, the staff reviewed the enhancement andconfirmed that the implementation of the enhancement prior to the period of extended operationwould result in the existing AMP being consistent with the GALL Report AMP to which it wascompared. The staff concluded that the applicant had demonstrated that the effects of agingwill be adequately managed so that the intended functions will be maintained consistent withthe current licensing basis (CLB) for the period of extended operation, as required by10 CFR 54.21(a)(3). The staff also reviewed the UFSAR supplement for this AMP andconcluded that, with revision, it provides an adequate summary description of the program, asrequired by 10 CFR 54.21(d).

3.0.3.2..20 ASME Section XI Subsection IWE Program

Summary of Technical Information in the Application. The applicant's ASME Code Section XlSubsecd.ion IWE Program is described in LRA Section B.2.1.32, "ASME Section Xl SubsectionIWE Program.n In the LRA, the applicant stated that this is an existing program. This program isconsistent, with exceptions, with GALL AMP Xl.S1, "ASME Section Xl Subsection IWE."

During the 5301 full committee meeting of the ACRS, March 9, 2006, the committee reviewedthe LRA. for BFN Units 1, 2, and 3. The staff had closed the open items with a commitment toissue an SSER that will address a concern that the committee had raised on an open item ondrywell shell, specifically related to the aging management in the sand bed region. The AMRreview of this component is discussed in the SER dated January 12, 2006, (see SERSection 3.5.2.3.1). In resolving the open item, by letter dated April 4, 2006, the applicantcommitted to perform an ultrasonic testing (UT) thickness measurement as an enhancement tothe ASMIE Section Xl Subsection IWE Program as follows.

3-3

Page 16: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

These additional periodic inspections in the sand bed region require changes to theASME Section Xi Subsection IWE Program described in LRA Sections A.1.29 andB.2.1.32.

The following is to be added to the end of LRA Section A.1.29:

The ASME Section Xl Subsection IWE Program will be enhanced to requireultrasonic inspections of the Units 1, 2, and 3 drywell liner plate near the sandbed region. The first inspection on each unit will be performed prior to the periodof extended operation. Subsequent periodic inspections will be performed oneach unit at a period not to exceed 10 years. The results of these inspections willbe reviewed to ensure that the acceptance criteria of ASME Section XlSubsection IWE-3000 are met.

The following is to be added to the LRA Section B.2.1.32 Enhancements (Note that allprogram elements were reviewed and only those affected by this enhancement areincluded in the following additions to Section B.2.1.32):

The ASME Section Xl Subsection IWE Program will be enhanced to requireultrasonic inspections of the Units 1, 2, and 3 drywell liner plate near the sandbed region. The first inspection on each unit will be performed prior to the periodof extended operation. Subsequent periodic inspections will be performed oneach unit at a period not to exceed 10 years. The results of these inspections willbe reviewed to ensure that the acceptance criteria of ASME Section XlSubsection IWE-3000 are met.

Program Elements Affected:

Element 4 - Detection of Aging Effects

The frequency and scope of examination specified in 10 CFR 50.55a andSubsection IWE ensure that aging effects would be detected before theywould compromise the design-basis requirements. As indicated inIWE-2400, inservice examinations and pressure tests are performed inaccordance with one of two inspection programs, A or B, on a specifiedschedule. Under Inspection Program A, there are four inspection intervals(at 3,10, 23, and 40 years) for which 100% of the required examinationsmust be completed. Within each interval, there are various inspectionperiods for which a certain percentage of the examinations are to beperformed to reach 100% at the end of that interval. In addition, a generalvisual examination is performed once each inspection period. After40 years of operation, any future examinations will be performed inaccordance with Inspection Program B. Under Inspection Program B,starting with the time the plant is placed into service, there is an initialinspection interval of 10 years and successive inspection intervals of10 years each, during which 100% of the required examinations are to becompleted. An expedited examination of containment is required by10 CFR 50.55a in which an inservice (baseline) examination specified forthe first period of the first inspection interval for containment is to be

3-4

Page 17: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

performed by September 9, 2001. Thereafter, subsequent examinationsare performed every 10 years from the baseline examination. Regardingthe extent of examination, all accessible surfaces receive a visualexamination such as General Visual, VT-1, or V1T-3 (see table in item 3above). IWE-1240 requires augmented examinations (ExaminationCategory E-C) of containment surface areas subject to degradation. AVT-1 visual examination is performed for areas accessible from bothsides, and volumetric (ultrasonic thickness measurement) examination isperformed for areas accessible from only one side.

BFN Evaluation

Element 4 states 'The frequency and scope of examination specified in10 CFR 50.55a and Subsection IWE ensure that aging effects would bedetected before they would compromise the design-basis requirements.'The inspections associated with this enhancement are of the inaccessiblearea of the drywell shell liner plate and are in addition to the current BFNASME Section Xl, Subsection IWE procedural requirements. Theseinspections will provide additional assurance that there is no loss ofintended function of the drywell shell.

Element 5 - Monitoring and Trending

With the exception of inaccessible areas, all surfaces are monitored byvirtue of the examination requirements on a scheduled basis. Whencomponent examination results require evaluation of flaws, evaluation ofareas of degradation, or repairs, and the component is found to beacceptable for continued service, the areas containing such flaws,degradation, or repairs shall be reexamined during the next inspectionperiod, in accordance with Examination Category E-C. When thesereexaminations reveal that the flaws, areas of degradation, or repairsremain essentially unchanged for three consecutive inspection periods,these areas no longer require augmented examination in accordance WithExamination Category E-C.

BFN Evaluation

Element 5 states 'With the exception of inaccessible areas, all surfacesare monitored by virtue of the examination requirements on a scheduledbasis.' The inspections associated with this enhancement are of theinaccessible area of the drywell shell liner plate and are in addition to thecurrent BFN ASME Section Xl, Subsection IWE procedural requirements.These inspections will provide additional assurance that there is no lossof intended function of the drywell shell.

Element 6 - Acceptance Criteria

IWE-3000 provides acceptance standards for components of steelcontainments and liners of concrete containments. Table IWE-3410-1

3-5

Page 18: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

presents criteria to evaluate the acceptability of the containmentcomponents for service following the preservice examination and eachinservice examination. This table specifies the acceptance standard foreach examination category. Most of the acceptance standards rely onvisual examinations. Areas that are suspect require an engineeringevaluation or require correction by repair or replacement. For someexaminations, numerical values are specified for the acceptancestandards. For the containment steel shell or liner, material lossexceeding 10% of the nominal containment wall thickness, or materialloss that is projected to exceed 10% of the nominal containment wallthickness before the next examination, are documented. Such areas areto be accepted by engineering evaluation or corrected by repair orreplacement in accordance with IWE-3122.

BFN Evaluation

Element 6 states 'For the containment steel shell or liner, material lossexceeding 10% of the nominal containment wall thickness, or materialloss that is projected to exceed 10% of the nominal containment wallthickness before the next examination, are documented. Such areas areto be accepted by engineering evaluation or corrected by repair orreplacement in accordance with IWE-3122.' The acceptance criteria forthe inspections associated with this enhancement will provide additionalassurance that the design minimum wall thickness is being maintained. Ifduring the License Renewal examinations local areas of degradation arefound, IWE-3122 provides the acceptance criteria. If either the thicknessof the base metal in local areas is reduced by no more than 10% of thenominal plate thickness of the reduced thickness can be shown byengineering analysis to satisfy the requirements of the BFN DesignCriteria, the component is acceptable by engineering evaluation.Additionally, the noted degradation condition would be subject to the siteCorrective Action Program.

Staff Evaluation. As discussed in their letter dated March 23, 2006, the ACRS recommendedthat either the drywell refueling seals should be included within the scope of license renewaland be subjected to periodic inspections or the drywell shells should be subjected to periodicvolumetric inspections to detect external corrosion. The applicant addressed the drywellrefueling seals in followup to RAI 2.4-3 by letter dated May 31, 2005. The applicant's responseto RAI 2.4-3 stated that the Browns Ferry refueling seals are not within the scope of licenserenewal. In addressing the ACRS's concern, the applicant chose to perform periodic ultrasonicinspections of the drywell shell in the area of the sand bed region. The sand bed region waschosen for inspection because it is the terminus for the drainage pathway for water that mayenter the inaccessible area. By being a drainage pathway, it could be subjected to wetting anddrying in the lower areas near the sand bed region which could result in corrosion of the shell.

As discussed at the ACRS meeting, BFN will perform periodic UT of the Units 1, 2, and 3drywell in the area of the sand bed region. These UT thickness measurements will beperformed as an enhancement to the ASME Section Xi Subsection IWE License RenewalAging Management Program. BFN will perform the first inspection on each unit prior to the

3-6

Page 19: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

period of extended operation. Subsequent inspections will be performed on each unit at aninterval not to exceed 10 years. The results of these inspections will be reviewed to ensure thatthe acceptance criteria of ASME Section Subsection IWE-3000 are met during each inspection.The staff evaluated the applicant's acceptance criteria for the inspections associated with thisenhancement which will provide additional assurance that the design minimum wall thicknesswill be maintained and found it acceptable. The staff also found that these enhancements willaddress the aging concerns that staff documented previously in the RAI 3.5-4 and the periodicinspection provides assurance that any degradation identified will be suitably addressed andmanacred. Staff considers this open issue adequately resolved.

The applicant has also previously committed (Commitment # 46, BFN letter datedNovember 16, 2005) to perform supplementary inspections of the vertical portions of the drywellshell which were intended to provide the staff the necessary assurance that the potentialdegradation of the uninspectable side of the drywell will be monitored and managed. Theinspections of the drywell shell near the sand bed region are in addition to the inspectionsdiscussed in Enclosure 1 of the TVA letter to the NRC dated November 16, 2005. As discussedin this letter:

For Unit 1, TVA will perform one time confirmatory ultrasonic thickness measurements on thevertical cylindrical area immediately below the drywell flange.

For Units 2 and 3, TVA will perform one time confirmatory ultrasonic thickness measurementson a portion of the cylindrical section of the drywell in a region where liner plate is 0.75 inchesthick (i.e. below the drywell head).

UFSAR SupDlement. In LRA Section A.1.29 and supplement, the applicant provided theUFSAR supplement for the ASME Code Section Xl Subsection IWE Program. The staffreviewed this section and determined that the information in the UFSAR supplement with theabove revisions to the UFSAR supplement provides an adequate summary description of theprogram. The staff found that this section of the UFSAR supplement, with revision, met therequirements of 10 CFR 54.21 (d).

Conclusion. On the basis of its review, RAI responses, and audit of the applicant's program, thestaff determined that those program elements for which the applicant claimed consistency withthe GALL Report are consistent with the GALL Report. In addition, the staff reviewed theexceptions and the associated justifications and determined that the AMP, with exceptions, isadequate to manage the aging effects for which it is credited. The staff concluded that theapplicant had demonstrated that the effects of aging will be adequately managed so that theintended functions will be maintained consistent with the CLB for the period of extendedoperation, as required by 10 CFR 54.21(a)(3). The staff also reviewed the UFSAR supplementfor this AMP and concluded that, with revisions, it provides an adequate summary description ofthe program, as required by 10 CFR 54.21(d).

3.0.3.3 AMPs That Are Not Consistent with or Not Addressed in the GALL Report

In its letter dated April 4, 2006, the applicant supplemented LRA Appendix B. The applicantidentified and added the following plant-specific AMP: Unit 1 Periodic Inspection Program(B.2.1.42)

3-7

Page 20: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

For AMPs that are not consistent with or not addressed by the GALL Report, the staffperformed a complete review of the AMPs to determine whether they were adequate to monitoror manage aging. The staff's review of these plant-specific AMPs is documented in thefollowing section of this SSER.

3.0.3.3.5 Unit 1 Periodic Inspection Program (B.2.1.42)

Summary of Technical Information in the Application. In the LRA, the applicant did not include adescription of the new, plant-specific AMP B.2.1.42, "Unit 1 Periodic Inspection Program."During the course of the staffs AMR of Unit 1 systems in layup for the extended outage, it wasrealized that neither the GALL-recommended one-time inspection nor the Unit 1 restartinspection would be sufficient in itself to monitor the effects of any new degradation that mightoccur during the period of extended operation. This plant-specific program is designed tomonitor the condition of and perform periodic inspections of components that were in layup andhave been requalified without replacement.

Staff Evaluation. In accordance with 10 CFR 54.21 (a)(3), the staff reviewed the informationincluded in AMP B.2.1.42 regarding the applicant's demonstration of the Unit 1 PeriodicInspection Program to ensure that the effects of aging will be adequately managed so that theintended functions will be maintained consistent with the CLB throughout the period of extendedoperation.

The staff reviewed the Unit 1 Periodic Inspection Program against the AMP elements found inthe SRP-LR Section A.1.2.3 and Table A.1-1, and focused on how the program manages agingeffects through the effective incorporation of the 10 program elements (i.e., program scope,preventive actions, parameters monitored or inspected, detection of aging effects, monitoringand trending, acceptance criteria, corrective actions, confirmation process, administrativecontrols, and operating experience).

The applicant indicated that the corrective actions, confirmation process, and administrativecontrols are part of the site-controlled quality assurance program. The staffs evaluation of thequality assurance program is discussed in SER Section 3.0.4. The remaining seven elementsare discussed below.

The program was initially submitted for review by the applicant's letter dated August 4, 2005.The staff review determined that the required information submitted was not entirely completeor consistent with the information identified in SRP-LR Section A.1.2.3. On September 2, 2005,in an informal communication (eight staff questions addressed below) and in a formal meetingsummary dated October 31, 2005, the staff requested additional information to support itsreview. The program was initially revised and resubmitted by TVA letter dated November 16,2005. Subsequently, by letters dated March 7 and April 4, 2006, the applicant submitted itsrevised Unit 1 Periodic Inspection Program to resolve staff comments and close out allremaining open items.

In NRC Question 1 of the informal staff request of September 2, 2005, the staff requested theapplicant to review the entire SRP-LR Section A.1.2.3 and to include additional applicableinformation. In NRC Question 2 of the informal staff request of September 2, 2005, the staffalso identified a general concern that, in the description of the program, the use of the term"failures" is not appropriate for license renewal. In response, the applicant revised the term

3-8

Page 21: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

"failures" to read, "acceptable degradation." The applicant also revised the UFSARSection A.2.4 and the description of each element to include the information identified inSRP-LR Section A. 1.2.3, as discussed below.

(1) Scope of Program - In LRA Section B.2.1.42, the applicant stated that the programprovides periodic monitoring of the non-replaced piping/fittings that were not in servicesupporting operation of Units 2 and 3. This piping is carbon/low-alloy or stainless steelthat was exposed to air, treated water, or raw water during the extended Unit 1shutdown. The susceptible locations identified are those areas determined to have thehighest potential for service-induced wear or latent aging effects. The staff found, ingeneral, the scope of the program to be comprehensive and acceptable because itincludes components that were subject to lay-up at locations most susceptible todegradation as a result of the extended outage. The applicant's response to Question 3of the informal staff request of September 2, 2005, by the revised letter datedNovember 16, 2005, did not include a detailed AMR table (Table 3) in a standard format.The format should list system and components, and it should reference the newinspection program, uB.2.1.42 Unit I Periodic Inspection Program," as the AMP. Thesubmitted format did not allow a staff review of specific combinations of components,materials, environments, and aging effects to be managed by the new Unit I PeriodicInspection Program. In addition, the applicant did not respond to NRC Question 3(b)concerning the number of sample locations. Instead, the applicant stated that its earlierresponse, dated May 18, 2005, in a table titfed,"NDE Examinations Performed forOriginal Non-replaced Piping, (3 sheets)," had identified specific components, piping,and welds that will be included in the scope of this new program. The applicant statedthat the table included piping and welds in the RHRSW, fire protection, EECW, rawcooling water, control rod drive, core spray, feedwater, high pressure coolant injection,main steam, reactor core isolation cooling, residual heat removal, and reactor buildingclosed cooling water systems. The staff accepts this list to satisfy the requirement of theprogram element "scope" in lieu of the detailed AMR table for purpose of this evaluation.However, in a teleconference on December 7, 2005, the applicant agreed (by letterdated December 20, 2005) to revise the LRA AMR tables (Table 3) to add the newlyidentified piping and components that will be included in the scope of the program andto identify these in appropriate systems tables in a future revision. Also, the applicantagreed to review the adequacy of the number of sample locations on the basis of a95/95 confidence level. By letter dated March 7, 2006, the applicant included a detaileddescription of the scope of the program and, by letter dated April 4, 2006, the applicantagain modified the scope of the program. The revised scope includes five commonmaterial and environment combinations and a comprehensive list of systems that werenot in service during the extended outage and are now subject to periodic inspections.These systems include all systems that were subject to moisture as a result of layupconditions during the extended outage. The inspection locations will be selected fromnon-replaced piping that is in-scope for license renewal and will include areas wheredegradation would be expected as well as areas where degradation would not beexpected.

The staff confirmed that the scope of program element satisfies the criterion defined inSRP-LR Section A.1.2.3.1. The staff concluded that the program attribute is acceptable.

3-9

Page 22: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

(2) Preventive Actions - In the initial preventive action program element, the applicantidentified the Unit 1 Periodic Inspection Program as a detection program. Programs arenormally identified as condition monitoring, performance monitoring, or prevention andmitigation programs. In NRC Question 5 of the informal staff request of September 2,2005, the staff requested the applicant to clarify that the program is a conditionmonitoring program. In the revised LRA Section B.2.1.42, the applicant stated that theprogram is a condition monitoring program and, thus, there are no preventive actions.The staff concurred with this assessment and does not identify the need for anypreventive actions associated with this program.

The staff confirmed that the preventive actions program element satisfies the criteriondefined in SRP-LR Section A.1.2.3.2. The staff concluded that the program attribute isacceptable.

(3) Parameters Monitored or Inspected - In LRA Section B.2.1.42, the applicant clarifiedthat the Unit 1 Periodic Inspection Program is a condition monitoring program and onlythe first two items of the SRP-LR are applicable. The applicant identified that theselected sample will be examined by the same or equivalent methodology (UT thicknessfor piping and UT shear wave and surface exam for weld), as performed to determineacceptability of not replacing piping sections prior to restart. The applicant stated thatthe susceptible locations were those areas determined to have the highest potential forservice-induced wear or latent aging effects, which includes all types of corrosion. Theapplicant also identified that the inspection techniques utilized evaluate internalconditions and are sensitive to the presence of unacceptable conditions, including wear,erosion, and corrosion (including crevice corrosion), if present. In addition, the applicantinitially identified that the sample selected for periodic inspection will be based on a90/90 confidence level consistent with the methodology identified in Electric PowerResearch Institute (EPRI) 107514. The staff was concerned that a 90/90 confidencelevel may not be appropriate and that EPRI 107514 had not been reviewed by the staff.In NRC Question 4 of the informal staff request of September 2, 2005, the staffrequested the applicant to clarify whether application of EPRI 107514 represented anindustry consensus for selecting a sample on the basis of 90/90 criteria. The applicantwas also requested to identify the sample size on the basis of 90/90 criteria versus95/95 and to justify selecting a sample size on the basis of the 90/90 criteria versus themore restrictive 95/95 criteria. In its response, dated November 16, 2005, the applicantrevised the sample size basis to reflect a confidence level of 95/95 and replaced theEPRI reference with "Elementary Statistical Analysis." TVA's letter dated April 4, 2006,clarified that the sample size for the 95/95 assurance criterion for the common materialand environment groupings will be based on NUREG-1 575. The staff's review of theacceptability of the revised basis for the sample size is further discussed underElement 4. The staff found that the parameters monitored or inspected will providesymptomatic evidence of potential degradation and, therefore, are acceptable.

The staff confirmed that the parameters monitored or inspected program elementsatisfies the criterion defined in SRP-LR Section A.1.2.3.3. The staff concluded that thisprogram attribute is acceptable.

(4) Detection of Aging Effects - SRP-LR Section A.1.2.3.4 states that the applicant is toprovide justification, including codes and standards referenced, that the inspection

3-10

Page 23: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

technique and frequency are adequate to detect the aging effects before a loss ofstructure and component (SC) intended function. In the initial submittal of LRASection B.2.1.42, the applicant did not identify any codes and standards. In NRCQuestion 6 of the informal staff request of September 2, 2005, the staff requested theapplicant to include additional information to demonstrate that the technique andfrequency of future inspections is justified. In revised LRA Section B.2.1.42, in itssubmittal dated November 16, 2005, the applicant stated that the program is notcovered by industry codes or standards and the selected inspection methodologies arebased on the inspections performed to determine whether components requirereplacement prior to restart. The applicant also stated that the examination techniquesutilized for the baseline inspection were ultrasonic thickness measurements for thepiping and ultrasonic shear wave for welds. The applicant identified that the restartinspections can be used as a baseline and additional periodic inspections of samplelocations will be performed after Unit 1 is returned to service and again within the first10 years of the period of extended operation. The ultrasonic thickness measurementsused should be capable of detecting most forms of internal degradation of the pipingcaused by the extended outage. The staff was concerned that inspections may not beperformed to recognized codes and standards and that UT inspection may not be thebest technique to detect certain types of corrosion. The staff believes that codes andstandards such as ASME Section V and ASTM are appropriate references. Based onindustry standards such as ASTM G46-94 and standard practices identified in EPRIdocuments and the GALL Report, visual inspections may be a more appropriatetechnique to identify certain types of internal degradation, such as pitting and MIC.Therefore, the applicant was requested to identify specific codes and standards used forperiodic inspections and evaluate the acceptability of UT alone to detect all forms ofcorrosion. In a teleconference with the applicant on December 7, 2005 (as referenced inthe applicant submittal dated December 20, 2005) the applicant indicated that internalvisual inspections are performed as part of other aging management programs whenthe system is open, but UT is preferred for periodic inspection trending purposes, sinceopportunistic internal inspections are limited by accessibility. By letter dated March 7,2006, the applicant clarified that the selected sample will be examined by UT thicknessfor piping and welds not covered by ASME Section Xl, and the program has beenrevised to select inspection locations from areas where degradation would be expectedas well as areas where degradation would not be expected. The applicant stated that ifunacceptable degradation is detected in any sample location, the unacceptabledegradation will be evaluated and dispositioned using the Corrective Action Program.The staff found a combination of opportunistic internal visual inspections combined withperiodic UT inspections to be an acceptable technique to detect latent aging effects.

In regard to the basis for the sample size addressed in the SRP-LR 'detection of agingeffects" element, the applicant described the sample size basis under Element 3,"parameters monitored or inspected."The applicant applied a statistical analysis toestablish a confidence level of 95/95 for selecting a sample size within a commonmaterial and environment. In SER Section A.2.4, submitted by letter dated October 19,2005, the applicant stated that if unacceptable degradation is identified, the sample sizewill be appropriately expanded. Although the applicant did not respond to staffs requestin NRC Question 3(b) concerning the number of sample locations (scope) to beinspected, the applicant did adequately identify the basis for the sample size. Thenumber of sample locations was subsequently identified in TVA draft letter dated

3-11

Page 24: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

March 7, 2006. The applicant clarified that the sample size will be based onNUREG-1475, with a minimum sample size of 59 locations for each material andenvironmental combination. In the event any inspection location fails the acceptancecriterion, the entire material and environment combination sampled is consideredsuspect and the unacceptable degradation must be evaluated and dispositioned usingthe Corrective Action Program.

The staff concurred that application of periodic internal visuals from other programs,combined with ultrasonic inspections from the periodic inspection program, areacceptable to detect potential aging effects that may have occurred as the result of theextended outage. Frequency of inspections is addressed under Element 5, below.

The staff found that the 95/95 confidence level is an acceptable basis for determining anadequate sample size and that, in the event unacceptable degradation is detected, aprovision to expand the sample size by considering all common material andenvironment combinations as suspect is consistent with NUREG-1475, industry practice,and SRP-LR Section A.1.2.3.4. The staff concluded that this program attribute isacceptable.

(5) Monitoring and Trending - In the initial submittal of LRA Section B.2.1.42, the applicantdid not identify whether results will be monitored and trended. In NRC Question 7 of theinformal staff request of September 2, 2005, the staff requested the applicant to clarifythat results will be monitored and trended. In its response, the applicant confirmed thatthe program has been revised to clarify the requirement to monitor and trend the resultsof periodic inspections. In revised LRA Section B.2.1.42, the applicant stated that theinspection frequency is re-evaluated each time the inspection is performed and can bechanged based on the trend of the results. SRP-LR Section A.1.2.3.5 states that plant-specific and/or industry-wide operating experience may be considered in evaluating theappropriateness of the technique and frequency. The applicant credits lessons learnedfrom the Units 2 and 3 restart experience, and TVA draft letter dated March 7, 2006,clarified that the baseline inspections will be performed on the selected sample locationsprior to restart. The first periodic inspection will be performed after Unit 1 is returned tooperation, but prior to the end of the current operating period, and the second periodicinspection of all sample locations will be completed within the first 10 years of the periodof extended operation. The applicant further clarified that, to ensure accurate andrepeatable baseline values are available, sample locations will be identified on controlleddrawings contained in the technical instruction for the Unit 1 Periodic InspectionProgram. The staff found that the overall monitoring and trending proposed by theapplicant is acceptable because there is reasonable assurance that effective periodicinspections at the frequency identified combined with the Corrective Action Program willeffectively manage the applicable aging effects.

The staff confirmed that the monitoring and trending program element satisfies thecriterion defined in SRP-LR Section A.1.2.3.5. The staff concluded that this programattribute is acceptable.

(6) Acceptance Criteria - In LRA Section B.2.1.42, revised by letter dated March 7, 2006,the applicant stated that the acceptance criteria is that the pipe wall will remain aboveminimum acceptable wall thickness until the next periodic inspection. The staff found the

3-12

Page 25: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

application of minimum wall thickness based on the Code of record to be reasonableand appropriate acceptance criteria to maintain the intended functions of thecomponents inspected.

The staff confirmed that the acceptance criteria program element satisfies the criteriondefined in SRP-LR Section A.1.2.3.6. The staff concluded that this program attribute isacceptable.

(10) Operating Experience - In NRC Question 8 of the informal staff request of September 2,2005, the staff requested the applicant to identify a commitment to provide (or haveavailable for review) operating experience for this new program in the future to confirmits effectiveness. The applicant's response confirmed that the program has been revisedto clarify the requirement to evaluate the results of the periodic inspections to verifyprogram effectiveness. In the revised version of LRA Section B.2.1.42, the applicantstated that the Unit 1 Periodic Inspection Program is a new program that will monitor theoperating conditions of Unit 1 components that were not replaced during the Unit 1restart. The applicant credits the trending data developed in Element 5 to demonstratethe effectiveness of the Unit 1 Periodic Inspection Program. The staff found that there isreasonable assurance that the use of trending data will provide objective evidence todetermine the effectiveness of the periodic inspection program.

The staff confirmed that the operating experience program element satisfies the criteriondefined in SRP-LR Section A.1.2.3.10. The staff concluded that this program attribute isacceptable.

UFSAR Supplement. By letter dated March 7, 2006, the applicant provided the following revisedUFSAR supplement for the Unit I Periodic Inspection Program:

A.2.4 Unit I Periodic Inspection Program

The Unit 1 Periodic Inspection Program is a new program that performs periodicinspections of the non-replaced piping/fittings that were not in service supportingoperation of Units 2 and 3 following the extended Unit I outage to verify that no latentaging effects are occurring, and to correct degraded conditions prior to loss of functimn.

The piping in the program is carbon/low-alloy or stainless steel that: 1) was exposed toair, treated water or raw water during the extended Unit 1 shutdown; and 2) will beexposed to treated water or raw water during normal operation. The inspection locationswill be selected from non-replaced piping which is within the scope of license renewaland will include areas where degradation would be expected as well as areas wheredegradation would not be expected. The sample selected for periodic inspection will bebased on a 95/95 confidence level on a common material and environment bases. Thesample size for the 95/95 assurance criterion for the common material and environmentgroupings will be based on NUREG-1475 as described in Chapter 21 which is based ona large or infinite lot size.

The initial sample, once selected, will be utilized in subsequent inspections. The initialbaseline inspection of the sample locations will be performed prior to restart. The firstUnit 1 periodic inspection of all sample locations will be performed after Unit 1 is

3-13

Page 26: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

returned to operation but prior to the end of the current operating period. The secondperiodic inspection of all sample locations will be completed within the first 10 years ofthe period of extended operation. The inspection frequency is re-evaluated each timethe inspection is performed and can be changed based on the trend of the results. Theinspections will continue until the trend of the results provides a basis to discontinue theinspections. However, as a minimum, periodic inspections of all selected samplelocations must be performed: 1) after Unit 1 is returned to operation but prior to the endof the current operating period; and 2) within the first 10 years of the period of extendedoperation.

The inspection techniques utilized evaluate internal conditions that are sensitive to thepresence of unacceptable conditions including wear, erosion, and corrosion (includingcrevice corrosion) if present. If unacceptable degradation is detected in any samplelocation, the unacceptable degradation will be evaluated and dispositioned using theCorrective Action Program.

The staff reviewed the above UFSAR supplement and determined that it provides an adequatesummary description of the program. The staff found that this section of the UFSARsupplement met the requirements of 10 CFR 54.21 (d).

Conclusion. On the basis of its review of the applicant's program, the staff found that the Unit 1Periodic Inspection Program adequately addresses the 10 program elements identified inAppendix A of the SRP-LR, and that the program can adequately manage the aging effects forwhich it is credited. The staff also reviewed the UFSAR supplement for this AMP and found thatit provides an adequate summary description of the program, as required by 10 CFR 54.21(d).

The following two AMR review items are presented in this SSER for background information onissues that were raised in the ACRS full committee meeting dated March 9, 2006, because ofwhich the enhancements to the two foregoing AMPs resulted. The following sections revise theprevious staff evaluations found in the final SER dated January 12, 2006.

3.3 Aging Management of Auxiliary Systems

3.3.2.3 AMR Results That Are Not Consistent with or Not Addressed in the GALL Report

3.3.2.3.3 Residual Heat Removal Service Water System - Summary of Aging ManagementEvaluation - Table 3.3.2.3

InsDection of Residual Heat Removal Service Water (RHRSW) Pipinp. The staff reviewed LRATable 3.3.2.3, which summarizes the results of AMR evaluations for the RHRSW systemcomponent groups. This item originated from regional AMP inspections conducted duringDecember 2004 and a followup inspection September 2005, related to the RHRSW pump pitsuction pipes.

As part of its review of the LRA, the staff, by letter dated October 31, 2005, requestedsupplemental information needed to address four open items included in the ACRS interimevaluation of BFN's LRA and the staffs draft SER. This supplemental response to the staff'srequest concerns the open item from AMP inspection of RHRSW piping. The AMP inspection is

3-14

Page 27: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

documented by staff letter to the applicant dated November 7, 2005, "Browns Ferry NuclearPlant - Inspection Report 05000259/2005013, 05000260/2005013, and 05000296/2005013."

In its response, by letter dated November 16, 2005 the applicant stated:

The Residual Heat Removal Service Water (RHRSW) pump pit supplies waterfor both the RHRSW system and the Emergency Equipment Cooling Water(EECW) system. The RHRSW pump pit takes suction from three 24" cast ironpipes that are encased in concrete. These pipes are coated internally withcement. Each of the three 40 foot long pipes has a tee on the upstream endwhich receives raw cooling water from two Condenser Circulating Water (CCW)pump pits via sluice gate valves located in the CCW pump pits. There are sixsluice gates with two for each of the three encased pipes.

The three RHRSW inlet pipes are included in the BFN Open Cycle CoolingWater (OCCW) program. The inlets of these pipes are the injection point forcorrosion inhibitors and biocides that are used to maintain the EECW System.The chemicals being injected at the inlet of these pipes are used to treat theother components in the OCCW system, including those components located inthe RHRSW pump pits. These pipes receive the largest concentration ofchemicals.

rhe sluice gate utilizes a local manual closure mechanism. The function of the sluicegate valves is to allow isolation of the encased pipe for RHRSW pump pit or CCW pumppit maintenance. The sluice gate has no active safety function other than remainingopen to provide a flow path. The previously discussed raw water chemical treatmentsystem [System No. 23] injects chemicals or biocides immediately upstream of thesluice gates. The treated water immediately enters the throat of the valve and proceedson to the imbedded piping. Substantial chemical treatment does not come into contactwith the external portion of the sluice gate or its operator. Four of the six valves havebeen replaced in the past. The remaining two valves are scheduled to be replaced inJanuary 2006.

As part of the License Renewal Process, an NRC inspection of Aging ManagementPrograms (AMPs) was performed at Browns Ferry during the week of December 13,2004. During this inspection, TVA indicated that a one time inspection of the externalsurfaces of the OCCW piping that is exposed to raw water would be performed. It waslater determined that the external surface of the RHRSW pump pit inlet piping isencased in concrete and is not accessible for inspection. TVA did not specify an internalinspection for license renewal because the aging of the pipe internals is managed bycompliance with the requirements of Generic Letter 89-13 which is consistent withrequirements of NUREG 1801 for Aging Management Programs (AMPs) for Open CycleCooling Water Systems. In a follow-up NRC AMP inspection during the week ofSeptember 19, 2005, TVA was informed that the staffs expectation was that aninspection be performed on the internal surfaces of the subject pipe.

3-15

Page 28: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

Based on additional discussions with the NRC, BFN will perform the following threeactions:

(1) Perform a confirmatory inspection of the RHRSW pump pit supply piping usingunderwater cameras or other methods or techniques available at the time of theinspection. The inspection will include internal portions of one RHRSW pump pitsupply pipe, and to the extent possible, will identify flow restrictions and materialloss due to corrosion. The inspection will be performed from either the CCWpump pit or the RHRSW Pump Pit end of the pipe. This inspection will beperformed prior to the period of extended operation.

(2) BFN will include instructions in the CCW pump pit Preventive MaintenanceProgram to periodically inspect the sluice gate valves. This will be completedprior to the period of extended operation.

(3) BFN will perform a confirmatory inspection of the seismic restraints in theRHRSW pump pit. This inspection will be performed prior to the period ofextended operation.

These confirmatory inspection items are incorporated into the Open Cycle Cooling WaterSystem Program, as an enhancement to the previously approved staff evaluation. Theenhancement is shown in SSER Section 3.0.3.2.11.

The staff concluded that with the proposed inspection the component will continue to fulfill itsintended function (i.e., no pipe blockage) and the proposed enhancement to the OCCWSProgram is acceptable.

3.5 Aging Management of Containments. Structures, and Components Supports

3.5.2.3 AMR Results That Are Not Consistent with or Not Addressed in the GALL Report

3.5.2.3.1 Primary Containment Structures - Summary of Aging Management Evaluation -Table 3.5.2.1 - Drywell Liner plate inspection in the sand pocket regions

The staff reviewed this AMR item previously in RAI 3.5-4 dated December 10, 2004, wasdocumented previously in the final SER issued on January 12, 2006 (see SERSection 3.5.2.3.1). UT thickness measurements of the sand pocket area that were obtainedduring the U2C10 and U3C8 refueling outages for Units 2 and 3, respectively; and in 1999 and2002 for Unit 1 (0-TI-376 Appendix 9.7, page 4), indicated that the condition of the drywell steelliner plate in this area meets code requirements, and that this area should not be categorizedfor augmented examination. In that previous evaluation the staff, in concluding, stated:

Based on the detailed response, the staff found that the applicant has in place detailedprocedures for examining the concrete and steel components inside the drywell, andsystematic acceptance criteria. Since the applicant plans to continue this process duringthe extended period of operation and therefore, the staff found the applicant's processof detecting degradation of these components adequate and acceptable, and the staffsconcern described in RAI 3.5-4 is resolved.

3-16

Page 29: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

However, when the ACRS questioned the applicant on March 9, 2006, as to the details of therecent: inspections, the applicant provided details of the UT inspections that were conductedduring these outages for Units 1, 2, and 3 and earlier in 1997 and 1999. The staff found thesedetails of particular interest for Unit 1. Staff pursued the inquiry, especially an indicationidentified in a UT inspection conducted in 1997 in Unit 1.

In responding to this ACRS concern, the applicant, in its submittal dated April 4, 2006, stated:

UNIT 1 DRYWELL SHELL INSPECTION RESULTS

Inspections of the Unit I drywell liner plate in the area of the sand bed region wereperformed in 1987, 1997, 1999, 2002, and 2004. Six areas of the drywell liner plate wereultrasonically (UT) inspected for each of the noted years. Each of the areas is 7" longcircumferentially and 5" wide vertically. Each area starts immediately above the concretefloor at elevation 549.92'. Each area is divided into a 6" long by 4" rectangle divided into1" by 1" grid squares and identified physically using low stress stamps by the letters "A"thru "X" (144 total locations). An inclusion was initially detected at Area #2 grid "I", in the1999 inspection. An inclusion is particles of nonmetallic material usually oxides,sulphides, silicates, and such which are entrapped mechanically or are formed duringsolidification or by subsequent reaction within the solid metal. The following tableprovides the minimum and maximum thickness measured ultrasonically at the Area #2grid "I" for each inspection:

Year Maximum Minimum(inch) (inch)

1987 1.146 1.080

1997 1.126 1.106

1999 1.136 1.110

2002 1.142 1.113

2004 1.146 1.114

[Note: Inspection results are available on site for review.]

The nominal wall thickness is 1.125" for this area of the drywell liner plate. The ASMECode derived tolerance is 10% of nominal wall thickness which yields a minimum of1.0125". Any readings below 1.0125" require documenting per the site correctiveprogram and an engineering evaluation. As can be seen, all of the measurements areabove the minimum criteria and indicate no trend in wall loss.

In performing the ultrasonic inspection of this area, the inclusion was noted at a depth of0.766". There was minimum loss of back wall signal with an associated signal at 0.7136"depth and no appreciable length (one half of a transducer diameter; transducer diameteris 3/8"), confirming the inclusion is small and sub-surface. Subsequent inspectionsrevealed no measurable difference in the depth / size of the inclusion and no change inthe thickness in the liner in this area. The inspection results were reviewed by a Level 3

3-17

Page 30: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

inspector and found to be non-recordable in accordance with ASME/ASTM SpecificationSA 516. The inclusion was noted in the inspection results as an aid to inspectorsperforming future inspections of the area. The presence of the inclusion does not affectthe strength of the drywell containment shell, and since it does not connect to thesurface of the liner plate, it does not represent a site for future corrosion. No additionalcomponent, material, environment, or program was brought into scope as a result of thisinclusion.

On March 9, 2006, the applicant also met with the ACRS and the NRC staff and confirmed thedetails of these inspections. Because of the previous operational history of the drywell shell inthe sandbed region the applicant agreed and the staff concurs, that proposed revision wouldadequately supplement the AMP on ASME Section Xl Subsection IWE Program in managingthe component. Also, after evaluating the data provided and documented in TVA submittaldated April 4, 2006, the staff concluded that the presence of the inclusion does not affect thestrength of the drywell containment shell and as it does not connect to other corroded areas, itdoes not represent a site for future corrosion. The revised commitment to perform periodic UTexaminations of the drywell shell in the sand-pocket areas, is shown as an augmentation to thepreviously approved staff evaluation of the ASME Section Xl Subsection IWE Program. Theenhancement is described in SSER Section 3.0.3.2.20. Therefore, the staff considers the openissue resolved.

3.5.3 Conclusion

The staff concluded that the applicant provided sufficient information to demonstrate that theeffects of aging of the containments, structures, and component supports components that arewithin the scope of license renewal and subject to an AMR will be adequately managed so thatthe intended function(s) will be maintained consistent with the CLB for the period of extendedoperation, as required by 10 CFR 54.21 (a)(3).

The staff also reviewed the applicable UFSAR supplement program summaries and concludedthat they adequately describe the AMPs credited for managing aging of the containments,structures, and component supports, as required by 10 CFR 54.21(d).

3.8 Conclusion for Aging Management

The staff reviewed the information in LRA Section 3, "Aging Management Review Results," andAppendix B, 'Aging Management Programs and Activities." On the basis of its review of theAMR results and AMPs, the staff concluded that the applicant had demonstrated that the agingeffects will be adequately managed so that the intended functions will be maintained consistentwith the CLB for the period of extended operation, as required by 10 CFR 54.21 (a)(3). The staffalso reviewed the applicable UFSAR supplement program summaries and concluded that theUFSAR supplement adequately describes the AMPs credited for managing aging as requiredby 10 CFR 54.21(d).

With regard to these matters, the staff concluded that there is reasonable assurance that theactivities authorized by the renewed license will continue to be conducted in accordance withthe CLB, and that any changes made to the BFN CLB in order to comply with10 CFR 54.21(a)(3) are in accord with the Atomic Energy Act of 1954, as amended, and NRCregulations.

3-18

Page 31: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

SECTION 5

REVIEW BY THE ADVISORY COMMITTEE ON REACTORSAFEGUARDS

The NRC staff issued its safety evaluation report (SER) with open items related to the renewalof operating licenses for Browns Ferry Nuclear Plant, Units 1, 2, and 3 on August 9, 2005. OnOctober 5-6, 2005, the applicant presented its license renewal application, and the staffpresented its review findings to the Advisory Committee on Reactor Safeguards (ACRS) PlantLicense Renewal Subcommittee and Full Committee. The staff reviewed the applicant'scomments on the SER and completed its review of the license renewal application. The staff'sevaluation is documented in an SER that was issued by letter dated January 12, 2006.

During the 530h meeting of the ACRS, March 9, 2006, the ACRS completed its review of theBFN license renewal application and the NRC staffs SER. The ACRS documented its findingsin a letter to the Commission dated March 23, 2006. This supplement addresses thecommittee's concern as documented in the previous sections. A copy of this letter is providedon the following pages of this SSER section.

5-1

Page 32: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

THIS PAGE INTENTIONALLY LEFT BLANK

5-2

Page 33: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

ACRSR-2180March 23, 2006

The Honorable Nils J. DiazChairmanU.S. Nuclear Regulatory CommissionWashington, DC 20555-0001

SUBJECT: REPORT ON THE SAFETY ASPECTS OF THE LICENSE RENEWALAPPLICATION FOR THE BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3

Dear Chairman Diaz:

During the 530th meeting of the Advisory Committee on Reactor Safeguards, March 9-11,2006, we completed our review of the license renewal application (LRA) for the Browns FerryNuclear Plant (BFN) Units 1, 2, and 3 and the associated final Safety Evaluation Report (SER)prepared by the NRC staff. On August 23, 2005, we visited the Browns Ferry site and reviewedactivities under way for license renewal, power uprate, and restart. Our Plant Operations andPlant License Renewal Subcommittees also reviewed these matters on September 21, 2005.Our Plant License Renewal Subcommittee reviewed the LRA and SER with Open Items onOctober 5, 2005. We issued an interim letter on the safety aspects of this application onOctober 19, 2005. During our reviews, we had the benefit of discussions with representativesof the NRC staff, including Region II personnel, and the Tennessee Valley Authority (TVA). Wealso had the benefit of the documents referenced. This report fulfills the requirements of10 CFR 54.25 that the ACRS review and report on all license renewal applications.

CONCLUSIONS AND RECOMMENDATIONS

1. With the inclusion of the conditions in Recommendations 2 and 3, the application forlicense renewal for BFN Units 1, 2, and 3 should be approved.

2. The drywell refueling seals should be included within the scope of license renewal andbe subjected to periodic inspections. Alternatively, as proposed by the staff, the drywellshells should be subjected to periodic volumetric inspections to detect externalcorrosion.

3. If the extended power uprate (EPU) is implemented before the period of extendedoperation, the staff should require that TVA evaluate the operating experience ofUnits 1, 2, and 3 at the uprated power level and then incorporate lessons learned intotheir aging management programs prior to entering the period of extended operation.

DISCUSSION

TVA requested renewal of the BFN Units 1, 2, and 3 operating licenses for 20 years beyondtheir current operating terms, which expire on December 10, 2013, June 28, 2014, and July 2,2016, respectively.

5-3

Page 34: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

The BFN site is located in Limestone County, Alabama on the north shore of the WheelerReservoir. All three BFN units are General Electric boiling water reactors (BWR 4) with Mark 1containments. Units 1 and 2 commenced operation in 1973 and 1974 respectively and wereboth shut down after the March 22, 1975 fire in Unit 1. Both units were returned to service in1976, the same year Unit 3 commenced operation. All three units operated until 1985, whenthey were shut down to address management, technical, and regulatory issues. Units 2 and 3were restarted in 1991 and 1995 respectively and have been in operation since then. Unit 1has been shut down since 1985 and TVA plans to restart it in May 2007. The approximateduration of power operation of the three units is 10 years for Unit 1, 23 years for Unit 2, and 18years for Unit 3. As part of an extensive restart program for Unit 1, components that have beenin "layup" for the past 20 years will be either replaced or requalified. Layup is intended toprovide a controlled environment to limit corrosion of plant components.

BFN Unit I is currently not identical to Units 2 and 3. TVA has committed to implement all ofthe physical and programmatic improvements to Unit 1 that have been made to Units 2 and 3.By the time of restart, the Unit 1 licensing basis will be identical to that of the other two units.The three units will have nearly identical components, materials, environments, operatingprocedures, and technical specifications. The Corrective Action Program applies to all threeunits, so that any condition identified in one unit will be reviewed for generic implications to theother units. The applicant states that, because all three units contain the same materials andhave experienced the same conditions, the aging mechanisms during the layup and recoveryperiods are similar among the three units. Since the aging effects of the Unit 1 shutdown aresimilar to those experienced in Units 2 and 3, the applicant has used operating experience fromthe restart of Units 2 and 3 in the recovery of Unit 1. Based on these considerations, TVA hassubmitted a common license renewal application for all three units.

In part because it is not clear to what extent the layup experience of Units 2 and 3 parallels theexperience of Unit 1, in our interim report we questioned the extent of applicability of Units 2and 3 operating experience to the unique operating history of Unit 1. The SER states that a1987 NRC inspection report identified several instances of deficient layup conditions during theearly phase of the extended outage. This raises the possibility of potential latent effects thatcould result in accelerated aging once the plant restarts and operates at power. The applicantacknowledges this concern by stating on page B-4 of the LRA that "During the performance ofIijRMI5juu U A -r *t-AAC thor~n MiAie rrtnnnifnirn fhnf thn nnorntinn nvnorLQnv'

Page 35: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

restarted and again within the first ten years of the period of extended operation. Theinspection frequency will depend on the results of each inspection. The acceptance criteria arethat the pipe wall remains above the minimum acceptable thickness until the next inspectionand no unacceptable weld cracks exist. We concur with the staffs conclusion that this programwill adequately manage the aging effects for which it is credited.

In the original BFN LRA, the applicant requested renewed licenses at EPU conditions for allthree units. In a letter dated January 7, 2005, TVA requested that the EPU and the LRA beseparated. Even though the staff reviewed the LRA based on current licensed power levels foreach unit, the final SER has several references to EPU conditions. The steam dryers areincluded in the scope of license renewal, but their aging management review will be performedas part of the safety evaluation of the EPU application. The time-limited aging analyses(TLAWs) associated with neutron embrittlement, reactor vessel fatigue, radiation degradation ofdrywell expansion gap foam, and stress relaxation of the core plate hold-down bolts wereperformed assuming EPU conditions.

In the final SER, the staff documents its review of the license renewal application and otherinformation submitted by TVA and obtained through the audits and inspections conducted at theplant site. The staff reviewed the completeness of the applicant's identification of structures,systems, and components (SSCs) that are within the scope of license renewal; the integratedplant assessment process; the applicant's identification of the plausible aging mechanismsassociated with passive, long-lived components; the adequacy of the applicant's agingmanagement programs (AMPs); and the identification and assessment of TLAAs requiringreview.

The BFN application either demonstrates consistency of aging management programs with theGeneric Aging Lessons Leamed (GALL) Report or documents deviations from the approachesspecified in the GALL Report. The staff reviewed this application in accordance withNUREG-1 800, the Standard Review Plan for Review of License Renewal Applications forNuclear Power Plants.

The slaff also performed inspections and an audit of AMPs and aging management reviews(AMR,;). A recent inspection found that the applicant had made significant progress indeveloping the AMP implementation packages but identified errors in them. The applicantinitiated a Problem Evaluation Report to identify the causes of the errors and determinecorrective actions to prevent recurrence. Inspections performed before BFN enters the periodof extended operation should verify that implemented corrective actions have been effective.

The audit of the AMPs and AMRs is documented in a report by the Brookhaven NationalLaboratory. The audit examined 28 AMPs and the associated AMRs and verified that the AMPsare consistent with the GALL Report or concluded that they would adequately manage agingduring the period of extended operation. Several of the existing AMPs will be enhanced toinclude Unit 1 prior to the period of extended operation. Appendix F of the LRA describes TVA's plan to resolve the differences between the licensing bases of Unit 1 and Units 2 and 3before Unit 1 restart. The staffs review of Appendix F did not identify any omissions ordiscrepancies.

The staff concluded that the scoping and screening processes implemented by the applicanthave successfully identified SSCs within the scope of license renewal and subject to an AM:R.

5-5

Page 36: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

With the inclusion in the scope of license renewal of those Unit I systems and components thatwere in layup and have not been replaced, we agree with this conclusion.

Open Item 2.4-3 in the SER concerns aging management of drywell shell corrosion. The staffwas concerned that leakage through refueling seals at the top of the drywell could lead tocorrosion of the drywell shell in a location that cannot be inspected. This aging effect has beenobserved in several Mark I containments and is the subject of Generic Letter 87-05 andInformation Notice 86-99 on the potential for corrosion of BWR Mark I steel drywells in thesandpocket region. The staff has concluded that the refueling seals should be within the scopeof license renewal because they are nonsafety-related components whose failure can affect theintegrity of the safety-related containment steel liner. We concur with this conclusion.

The applicant acknowledges that water was observed below the refueling seals at BFN Unit 3during the 1998 refueling outage, but maintains that the refueling seals should not be within thescope of license renewal. As an alternative to the inclusion of the seals, the staff proposed thatTVA periodically perform ultrasonic testing of the drywell shells as part of the containmentinservice inspection program. Such an approach has been used by previous license renewalapplicants, and we agree that it is an acceptable alternative. As an alternative to the staffsproposal, the applicant committed to perform a one-time confirmatory inspection of the Unit 1drywell shell prior to restart and of the Units 2 and 3 shells prior to entering the period ofextended operation. Based on this commitment, the staff closed out this open item. We do notagree with this resolution. One-time inspections are intended to confirm that an unexpectedaging effect is not occurring or is occurring at such a slow rate that no further inspections arerequired. This aging effect has been observed in several Mark I containments, and we areaware of at least one instance of through-wall corrosion. One-time inspection of the shell doesnot provide assurance that leakage of the refueling seals after the one-time inspection isperformed will not create an environment that could result in future drywell degradation. Unlessthe applicant can demonstrate that the resulting corrosion rate would not be sufficient todegrade the pressure retaining function during the period of extended operation, the refuelingseals should be within the scope of license renewal and subject to periodic inspections, or thedrywell shells should be subjected to periodic volumetric inspections.

During our March 9, 2006 meeting, we were told that the staff has reopened this item based ondiscussions with the applicant regarding drywell inspection results. Ultrasonic inspectionsperformed in 1999, 2002, and 2004 identified a small inclusion in the drywell liner of Unit 1. Theapplicant will submit this information to the staff in writing. The staff plans to document itsevaluation of this information in a supplemental SER. Based on our discussions with theapplicant and staff, the resolution of this issue does not affect our recommendations regardingthis LRA.

In our interim letter we noted that in the draft SER some restart inspections were referred to as"one-time" inspections. We suggested that, to avoid confusion, the term "one-time" inspectionshould be used only for license-renewal-related inspections. For clarification purposes, the finalSER now provides definitions of one-time inspections, restart inspections, and Unit 1 periodicinspections. Section 3.7 of the final SER still refers to some restart inspections as one-timeinspections. The final SER should be revised to be consistent with these definitions.

The applicant has identified systems and components requiring a TLAA and reevaluated themfor 20 more years of operation. The SER concludes that the TLAAs are valid for the period of

5-6

Page 37: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

extended operation, the TLAAs are projected to the end of the period of extended operation, orthat aging effects will be adequately managed for the period of extended operation. We concurwith this assessment.

According to current plans, all three BFN units will be subjected to an EPU that will raise theirpower output to 3952 MWt prior to entering the period of extended operation. However, theLRA and the associated SER reflect operating experience only at the current power level. If theEPU is implemented before the period of extended operation, the staff should require that V/Aevaluate the operating experience of Units 1, 2, and 3 at the uprated power level and thenincorporate lessons learned into their aging management programs prior to entering the periodof extended operation. The EDO response to our interim letter stated that the staffs SER forthe EPU would include a commitment to perform such an evaluation.

With the inclusion of commitments to perform periodic inspections of BFN Units 1, 2, and 3drywell refueling seals or drywell shells and to perform an evaluation of operating experience atthe EPLJ level and incorporate lessons learned into their aging management programs prior loentering the period of extended operation, the application for license renewal of Browns FerryUnits 1, 2, and 3 should be approved.

Sincerely,

/IR

Graham B. WallisChairman

References:1. U.S. Nuclear Regulatory Commission, "Safety Evaluation Report Related to the License Renewal

of the Browns Ferry Nuclear Plant, Units 1, 2, and 3," January 2006.2. U.S. Nuclear Regulatory Commission, "Safety Evaluation Report with Open Items Related to the

License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and 3," August 2005.3. Tennessee Valley Authority, "Browns Ferry Nuclear Plant (BFN) - Units 1, 2, and 3 - Application

for Renewed Operating Licenses," December 31, 2003.4. Tennessee Valley Authority, "Browns Ferry Nuclear Plant (BFN) - Units 1, 2. and 3 - January 28,

2004 Meeting Follow-Up - Additional Information," February 19, 2004.5. Brookhaven National Laboratory, "Audit and Review Report for Plant Aging Management

Programs (AMPs) and Aging Management Reviews (AMRs), Browns Ferry Nuclear PlantUnits 1, 2, and 3, Docket Nos.: 05000259, 05000260, 05000296," April 26, 2005.

6. U.S. Nuclear Regulatory Commission, "Browns Ferry Nuclear Plant - Inspection ReportC15000259/2004012, 05000260/2004012, and 05000296/2004012," January 27, 2005.

7. U.S. Nuclear Regulatory Commission, "Browns Ferry Nuclear Plant - Inspection Report05000259/2005013, 05000260/2005013, and 05000296/2005013," November 7, 2005.

8. Tennessee Valley Authority, "Browns Ferry Nuclear Plant (BFN) - Units 1, 2, and 3 LicenseRenewal Application (LRA) - Annual Update (TAC Nos. MC1704, MC1 705, and MC1 706),"January 31, 2006.

9. Letter from William J. Shack, Acting Chairman, ACRS, to Luis A. Reyes, Executive Director forOperations, NRC, "Interim Report on the Safety Aspects of the License Renewal Application forthe Browns Ferry Nuclear Plant, Units 1, 2, and 3," October 19, 2005.

10. Letter from Luis A. Reyes, Executive Director for Operations, NRC, to William J. Shack, ActingChairman, ACRS, "Response to Advisory Committee on Reactor Safeguards - Interim Report on

5-7

Page 38: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

* the Safety Aspects of the License Renewal Application for Browns Ferry Nuclear Plant, Units 1, 2,and 3," November 28, 2005.

11. Tennessee Valley Authority, "Browns Ferry Nuclear Plant (BFN) - Units 1, 2, and 3 - Summary ofNRC Site Visit and Meeting Regarding Extended Power Uprate (EPU) and License RenewalApplication (LRA)," January 7, 2005.

12. U.S. Nuclear Regulatory Commission,"10 CFR Parts 2, 50, 54, and 140, Nuclear Power PlantLicense Renewal," Federal Register, Vol. 54, No. 240, December 13,1991, pp. 64943-64980.

13. U.S. Nuclear Regulatory Commission,"10 CFR Parts 2, 51, and 54, Nuclear Power Plant LicenseRenewal; Revisions," Federal Register, Vol. 60, No. 88, May 8, 1995, pp. 22461-22495.

5-8

Page 39: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

SECTION 6

CONCLUSIONS

The staff of the U.S. Nuclear Regulatory Commission (NRC or the Commission) reviewed thelicense renewal applications for the Browns Ferry Nuclear, Units 1, 2, and 3, in accordance withCommission regulations and NUREG-1800, "Standard Review Plan for Review of LicenseRenewal Applications for Nuclear Power Plants," dated July 2001. Title 10, Section 54.29, ofthe Code of Federal Regulations (10 CFR 54.29) provides the standards for issuance of arenewed license.

On the basis of its evaluation of the license renewal applications, the NRC staff concluded thatthe requirements of 10 CFR 54.29(a) have been met and that all open items and confirmatoryitems have been resolved.

The staff notes that any requirements of Subpart A of 10 CFR Part 51 are documented inSupplement 21 to NUREG-1437, "Generic Environmental Impact Statement for LicenseRenewal of Nuclear Plants: Regarding Browns Ferry Nuclear, Units 1, 2, and 3, Final Report,"dated June 23, 2005.

6-1

Page 40: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

THIS PAGE INTENTIONALLY LEFT BLANK

Page 41: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

APPENDIX ACOMMITMENTS FOR LICENSE RENEWALS

OF BFN UNITS 1, 2, AND 3

During the review of the Browns Ferry Nuclear Plant (BFN) license renewal application (LRA) bythe U.S. Nuclear Regulatory Commission (NRC) staff, the applicant made commitments relatedto aging management programs (AMPs) to manage aging effects of structures and components(SCs) before the period of extended operation. The following tables list these commitments,along with the implementation schedules and the sources of the commitments.

* Table 1 lists those commitments that are not for a specific unit.

* Table 2 lists commitments that are specific to Unit 1.

Note that these tables also contain non-AMP commitments.

Changes to the attached Commitment Tables reflect changes made as a result of the changesdelineated in Enclosure 1 of the letter dated April 4, 2006. The following items are revised:

* Item 15 of Table 1* Item 28 of Table 1* Item 45 of Table 1* Item 48 of Table 1* Item 49 of Table 2

Also, Items 50 through 62 of Table 3 were revised to add the TVA response dated March 2,2006, as a source document.

Also, Items 52 of Table 3 was revised to add the TVA response dated April 21, 2006, as asource document.

A-1

Page 42: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

THIS PAGE IS INTENTIONALLY LEFT BLANK

A-2

Page 43: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)1. Accessible Non- Develop and implement new program. A.1.1 Prior to the period of * LRA Section B.2.1.1Environmental extended operation

Qualification Cablesand ConnectionsInspection Program

2. Electrical Cables Not Revise implementing documents for A.1.2 Prior to the period of * LRA Section B.2.1.2Subject to LPRM cable system aging to reference extended operation * Response to follow-10 CFR 50.49 existing Technical Specification up to RAI 2.5-2 datedEnvironmental requirements and license renewal March 2, 2005Qualification reference(s).Requirements Usedin Instrumentation Develop and implement new program to Prior to the period of * LRA Section 6.2.1.2Circuits Program manage IRM cable system aging. extended operation * Response to follow-

up to RAI 2.5-2 datedMarch 2, 2005

3. Inaccessible Medium Develop and implement new program to A.1.3 Prior to the period of * LRA Section 6.2.1.3Voltage Cables Not manage the medium-voltage cables to the extended operation * Response to RAI 3.6-Subject to 10 CFR Residual Heat Removal Service Water 3(a) dated50.49 Environmental pumps. December 9, 2004Qualification * Response to follow-Requirements up RAI 3.6-3 datedProgram January 18, 2005

4. ASME Section Xl Revise implementing documents to A.1.4 Prior to the period of * LRA Section 6.2.1.4Inservice Inspection include license renewal reference(s). extended operationSubsections IWB,IWC, and IWDProgram

5. Chemistry Control Revise implementing documents to A.1.5 Prior to the period of * LRA Section B.2.1.5Program I include license renewal reference(s). | | extended operation ll

A-3

Page 44: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

6. Reactor Head Revise implementing documents to A.1.6 Prior to the period of * LRA Section B.2.1.6Closure Studs include license renewal reference(s). extended operationProgram

7. Boiling Water Revise implementing documents to A.1.7 Prior to the period of * LRA Section B.2.1.7Reactor Vessel include license renewal reference(s). extended operationInside DiameterAttachment WeldsProgram

8. Boiling Water Revise implementing documents to A.1.8 Prior to the period of * LRA Section B.2.1.8Reactor Feedwater include license renewal reference(s). extended operationNozzle Program

9. Boiling Water Revise implementing documents to A.1.9 Prior to the period of * LRA Section B.2.1.9Reactor Control Rod include license renewal reference(s). extended operationDrive Return LineNozzle Program .

10 Boiling Water Revise implementing documents to A.1.10 Prior to the period of * LRA Section B.2.1.10Reactor Stress include license renewal reference(s). extended operationCorrosion CrackingProgram

11. Boiling Water Revise implementing documents to A.1.1 1 Prior to the period of * LRA Section B.2.1.11Reactor Penetrations include license renewal reference(s). extended operation * Enclosure 1 of TVAProgram letter dated

September 14, 2005

A-4

Page 45: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

( I 111 A MI

12. Boiling Water Revise implementing documents to A.1.12 Prior to the period of * LRA Section B.2.1.12Reactor Vessel include license renewal reference(s). extended operationInternals Program

Inspect the top guide beams Prior to the period of * Response to NRCextended operation Question (3) dated

May 25, 2005

Establish an aging management program Two years before the * Response tofor the steam dryers. first BFN unit enters the RAI 3.1-1 dated

period of extended January 31, 2005operation

Enhance the Reactor Pressure Vessel Two years before the * Response to RAIInternals Inspection (RPVII) Units 1, 2, first BFN unit enters the B.2.1.12-1 (C) datedand 3 procedure to require visual period of extended January 31, 2005inspection of the Access Hole Covers operation * Response to NRC(AHCs) and inspection of the AHC welds. Question (7) dated

May 25, 2005

Implement the inspection of weld TS-2 When inspection * Response to(BWRVIP-41). technique for weld TS-2 Question (12) dated

being developed by the May 25, 2005BWRVIP InspectionCommittee is available.

13. Flow-Accelerated Revise implementing documents to A.1.14 Prior to the period of * LRA Section B.2.1.15Corrosion Program include license renewal reference(s). extended operation

14. Bolting Integrity Revise implementing documents to A.1.15 Prior to the period of * LRA Section B.2.1.16Program include license renewal reference(s). extended operation

A-5

Page 46: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule(UFSAR)

15. Open-Cycle Cooling Revise implementing documents to A.1.16 Prior to the period of * LRA Section B.2.1.17Water System include license renewal reference(s). extended operationProgram Enhance the Open-Cycle Cooling Water Once prior to the period * Enclosure 1 of TVASystem Program to perform confirmatory of extended operation letter dated April 4,inspections of the RHRSW pump pit 2006supply piping, sluice gate valves and Within 10 years afterseismic restraints in the RHRSW pump entering the period ofpit. extended operation

16. Closed-Cycle Revise implementing documents to A.1.17 Prior to the period of * LRA Section B.2.1.18Cooling Water include license renewal reference(s). extended operationSystem Program

17. Inspection of Revise implementing documents to A.1.18 Prior to the period of * LRA Section B.2.1.20Overhead Heavy include license renewal reference(s). extended operationLoad and Light LoadHandling SystemsProgram

18. Compressed Air Revise implementing documents to: A.1.19 Prior to the period of * LRA Section B.2.1.21Monitoring Program * Include license renewal reference(s). extended operation* Incorporate guidelines in ASME OM-

S/G-2000, Part 17; ANSI/ISA-S7.0.01-1996; and EPRI TR 108147

19. BWR Reactor Water Revise implementing documents to A.1.20 Prior to the period of * LRA Section B.2.1.22Cleanup System include license renewal reference(s). extended operationProgram

20. Fire Protection Revise implementing documents to A.1.21 Prior to the period of * LRA Section B.2.1.23Program include license renewal reference(s). extended operation

A-6

Page 47: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR _

21. Fire Water System Revise implementing documents to: A.1.22 Prior to the period of * LRA Section B.2.1.24Program * Include license renewal reference(s). extended operation* Perform flow tests or non-intrusive

examinations to identify evidence ofloss of material due to corrosion.

Perform sprinkler head inspections to Prior to exceeding the * LRA Section B.2.1.24ensure signs of degradation, such as 50-year service life forcorrosion, are detected in a timely any sprinklermanner.

22. Aboveground Carbon Revise implementing documents to A.1.23 Prior to the period of * LRA Section B.2.1.26Steel Tanks Program include license renewal reference(s). extended operation

23. Fuel Oil Chemistry Revise implementing documents to A.1.24 Prior to the period of * LRA Section B.2.1.27Program include license renewal reference(s). extended operation * Enclosure 1 of TVAletter datedSeptember 14, 2005

A-7

Page 48: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

24. Reactor Vessel Revise implementing documents to A.1.25 Prior to the period of * LRA Section B.2.1.28Surveillance include license renewal reference(s). extended operationProgram Enhance the Integrated Surveillance Prior to the period of * LRA Section B.2.1.28

Program (ISP) per proposed BWRVIP- extended operation116.

If the ISP is not approved two years prior Two years prior to the * Response to RAIto the commencement of the license commencement of the B.2.1.28-1 (A) datedrenewal period, a plant-specific license renewal period January 31, 2005surveillance program for each BFN unit * Response towill be submitted to the NRC. Question (9) dated

May 25, 2005

Maintain Unit 1 and Unit 3 surveillance Unit 3 is ongoing * Response tocapsules (standby capsules) available to Unit 1 will commence at Question (10) datedthe ISP. restart May 25, 2005

A-8

Page 49: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment _ LRA | Implementation | SourceAppendix A Schedule

(UFSAR)25. One-Time Inspection Develop and implement new program. A.1.26 Prior to the period of * LRA Section B.2.1.29Program extended operation

Develop and submit procedure for NRC At least two years prior * Response toreview. to the expiration of the Proposed Unresolved

current operating license Item 3.0-4 LP dated__ May 27, 2005

Perform a one-time inspection of the Prior to the period of * Response to RAIASME equivalent Class MC supports in a extended operation B.2.1.33-2 datedsubmerged environment of the Units 2 January 18, 2005and 3 Torus.

Perform a one-time inspection of the in- Prior to the period of * Response toscope submerged concrete in one extended operation Question 359 datedindividual CCW pump bay of the Intake October 8, 2004Pumping Station. * Response to RAI

3.5-16 dated April 5,2005

Perform ultrasonic thickness Prior to the period of * Response to RAImeasurements of tank bottoms for those extended operation 7.1.19-1 datedtanks specified in the Fuel Oil Chemistry May 25, 2005Program (B.2.1.27) and the AbovegroundCarbon Steel Tanks Program (B.2.1.26).

A-9

Page 50: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT(NON-UNIT SPECIFIC)

PROGRAMS AND TLAAs

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

26. Selective Leaching of Develop and implement program. A.1.27 Prior to the period of * LRA Section B.2.1.30Materials Program extended operation

27. Buried Piping and Revise implementing documents to A.1.28 Prior to the period of * LRA Section B.2.1.31Tanks Inspection include license renewal reference(s). extended operationProgram Add a trigger to the excavation permit Complete * NRC Inspection

document to require notification of Report datedengineering to perform a piping inspection January 27, 2005when piping is excavated.

Determine (via engineering evaluation) if Within 10 years after * Response to RAIsufficient inspections have been entering the period of 7.1.22-1 datedperformed to draw conclusion regarding extended operation May 25, 2005ability of underground coating to protectpiping.

If required, conduct a focused inspectionto draw conclusion concerning thecoating.

Revise implementing documents to Complete * Response to RAIinspect buried piping when it is excavated. 7.1.22-1 dated

May 25, 2005

A-10

Page 51: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA | Implementation | SourceAppendix A ScheduleI (UFSARI

28. ASME Section Xl Revise implementing documents to A.1.29 Prior to the period of * LRA Section B.2.1.32Subsection IWE include license renewal reference(s). extended operationProgram Enhance ASME Section XI, Subsection First inspection on each * Enclosure 1 of TVA

IWE Program to perform a UT inspection unit prior to the period of letter dated April 4,of the sand bed area of the drywell liner of extended operation. 2006Units 1, 2, and 3.

Subsequent periodicinspections will beperformed on each unitat a period not to exceed10 years.

29. ASME Section Xl Revise implementing documents to A.1.30 Prior to the period of * LRA Section B.2.1.33Subsection IWF include license renewal reference(s). extended operation

Program Enhance program to manage the aging Prior to the period of * Response to Follow-effects of ASME equivalent Class MC extended operation up RAI B.2.1.33-1supports. dated May 31, 2005

30. 10 CFR 50 Appendix Revise implementing documents to A.1.31 Prior to the period of * LRA Section B.2.1.34J Program include license renewal reference(s). extended operation

31. Masonry Wall Revise implementing documents to A.1.32 Prior to the period of * LRA Section B.2.1.35Program include license renewal reference(s). extended operation

Revise implementing procedures to clearly Prior to the period of * LRA Section B.2.1.35identify structures with masonry walls extended operationwithin scope and to clarify qualificationrequirements for personnel who performmasonry wall walkdowns.

A-11

Page 52: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item NumberlTitle Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

32. Structures MonitoringProgram

Revise implementing documents toinclude license renewal reference(s).

A.1.33 Prior to the period ofextended operation

* LRA Section B.2.1.36

Enhance procedures implementingthe10 CFR 50.65 Maintenance RuleProgram to identify all structures andstructural components within scope.

Enhance procedures implementing the10 CFR 50.65 Maintenance Rule programsampling approach to includeexaminations of below-grade concretewhen excavated.

Prior to the period of * LRA Section B.2.1.36extended operation * Response to GALL

audit Question 173dated October 8,2004

* Response to GALLaudit Question 357dated October 8,2004

Prior to the period of * LRA Section B.2.1.36extended operation * Response to GALL

audit Question 285dated October 8,2004

Prior to the period of * LRA Section B.2.1.36extended operation

Enhance procedures implementing the10 CFR 50.65 Maintenance Rule programto include the guidance provided in ACI349.3R-96 Chapter 7.

Enhance LCEI-CI-C9, Attachment 1,"Buried Piping Inspection Checklist," toinclude "Mechanical Penetration" as aninspection attribute.

Prior to entering theperiod of extendedoperation

* Response to GALLaudit Question 285dated October 8,2004I I

A-12

Page 53: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation | SourceAppendix A Schedule

(UFSAR_

33. Inspection of Water- Revise implementing documents to A.1.34 Prior to the period of * LRA Section B.2.1.37Control Structures include license renewal reference(s). extended operationProgram Revise implementing documents to Prior to the period of * LRA Section B.2.1.37

identify required structures and structural extended operationcomponents within the scope of licenserenewal.

Revise implementing documents to Prior to the period of * LRA Section B.2.1.37include special inspections following the extended operationoccurrence of large floods, earthquakes,tornadoes, and intense rainfall.

Implement periodic monitoring of the raw Prior to the period of * Response to RAI 3.5-service water in close proximity to the extended operation 16 dated April 5,Intake Pumping Station for the 2005requirements of an aggressiveenvironment.

34. Environmental Revise implementing documents to A.1.35 Prior to the period of * LRA Section B.3.1Qualification include license renewal reference(s). extended operationProgram __

35. Fatigue Monitoring Implement enhanced Fatigue Monitoring A.1.36 Prior to the period of * LRA Section B.3.2Program Program using the EPRI-licensed extended operation

FatigueProO cycle counting and fatigueusage tracking computer program.

36. Systems Monitoring Revise implementing documents to A.2.1 Prior to the period of * LRA Section B.2.1.39Program include license renewal reference(s). extended operation * Enclosure 1 of TVA

letter datedSeptember 14, 2005

A-13

Page 54: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

37. Bus Inspection Develop and implement new program. A.2.2 Prior to the period of * LRA Section B.2.1.40Program extended operation * Response to RAI 3.6-

4 dated December 9,2004

38. Diesel Starting Air Revise implementing documents to A.2.3 Prior to the period of * LRA Section B.2.1.41Program include license renewal reference(s). extended operation

39. Time-Limited Aging Develop and submit revised P-T limits to A.3.1.5 Prior to the period of * LRA Section A.3.1.5Analysis: the NRC for approval. extended operation * LRA Section 4.2.5Reactor VesselThermal LimitAnalyses: OperatingPressure-Temperature Limits(P-T)

40. Time-Limited Aging Revise existing EQ program to cover the A.3.3 Prior to the period of * LRA Section A.3.3Analysis: extended period of operation. extended operation * LRA Section 4.4EnvironmentalQualification ofElectrical Equipment

41. Time-Limited Aging Implement an administrative tracking A.3.5.7 Prior to the period of * LRA Section A.3.5.7Analysis: system to ensure limiting number of extended operation * Response to RAIOther Plant Specific fatigue cycles will not be exceeded at the 4.7.8 dated March 2,Time-Limited Aging select EECW locations. 2005Analysis:EmergencyEquipment CoolingWater Weld FlawEvaluation .

A-14

Page 55: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule l

(UFSAR)

42. RAI 2.1-2,A-3 Identify additional piping segments and N/A Complete * Response to RAI 2.1-supports/equivalent anchors to be placed 2,A-3 datedin scope. September 3, 2004

* TVA response datedFebruary 28, 2005

43. RAI 2.1-2,B Implement Unit 1, 2, and 3 DCNs to N/A Prior to the period of * Response to RAI 2.1-qualify twelve temperature switches in the extended operation 2,B datedTurbine Building. September 3, 2004

44. RAI 2.1-2,C RHRSW Include 24-inch Raw Cooling Water N/A Complete * Response to RAI 2.1-tunnel discharge piping located in the RHRSW 2,C RHRSW Tunneltunnel in scope of license renewal. dated September 3,

2004* TVA response dated

January 31, 200545. RAI 2.1-2,C Intake Revise 10 CFR 54.4(a)(2) Scoping N/A Complete * Response to RAI 2.1-Pumping Station Methodology document to address 2,C Intake Pumping

components located in the lower Station datedcompartments of the Intake Pumping September 3, 2004Station.

46. Open Item 01 2.4-3 Perform one time confirmatory ultrasonic N/A Prior to the period of * Enclosures 1 and 9 ofthickness (UT) measurements on a extended operation TVA letter datedportion of the cylindrical section of the November 16, 2005drywell on Units 2 and 3.

A-15

Page 56: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 1: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(NON-UNIT SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

47. Open Item 01 4.7.7 Perform a BFN plant-specific analysis N/A Two years prior to the * Enclosures 3 and 9 ofconsistent with BWRVIP-25 to period of extended TVA letter dateddemonstrate that the core plate hold-down operation November 16, 2005bolts can withstand required loads,considering the effects of stress relaxationuntil the end of the period of extendedoperation. Take appropriate correctiveaction if the analysis does not satisfy thespecified criteria.

Submit the analysis or the correctiveaction taken to resolve the core plate hold-down bolt issue to the NRC for review.

48. Not Used

A-16

Page 57: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 2: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(UNIT I SPECIFIC)

NOTE: This Table does not contain all of the same Item Numbers as contained in Table 1. While there is a one-to-one correlationof items with the same number, the same Item Numbers are not in both tables as explained below:

* For Item Numbers 1 through 47, only those Item Numbers that have a Unit I specific commitment are inrdldAd in this tahI.* Item Numbers 49 and 63 applies only to Unit 1.

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)2. Electrical Cables Not Include Unit 1 High-Range Radiation A.1.2 Prior to Unit 1 restart * Response to GALLSubject to Monitoring cables in the Environmental audit Question 16910 CFR 50.49 Qualification (EQ) Program. dated October 8,Environmental 2004Qualification

Requirements Usedin InstrumentationCircuits Program

5. Chemistry Control Include Unit 1 in the program. A.1.5 Prior to Unit 1 restart * LRA Section B.2.1 .5Program

7. Boiling Water Include Unit 1 in the program. A.1.7 Prior to Unit 1 restart * LRA Section B.2.1.7Reactor VesselInside DiameterAttachment WeldsProgram

8. Boiling Water Upgrade Unit 1 operating procedures to A.1.8 Prior to Unit 1 restart * LRA Section B.2.1.8Reactor Feedwater decrease the magnitude and frequency ofNozzle Program feedwater temperature fluctuations.

10. Boiling Water Include Unit 1 in the program. A.1.10 Prior to Unit 1 restart * LRA Section B.2.1.10Reactor Stress * Response to GALLCorrosion Cracking audit Question 181Program dated October 8.

J .2004

A-17

Page 58: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 2: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(UNIT I SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

11. Boiling Water Include Unit 1 in the program. A.1.11 Prior to Unit 1 restart * LRA Section B.2.1.11Reactor Penetrations * Response to GALLProgram audit Question 194

dated October 8,2004

12. Boiling Water Include Unit 1 in the program. A.1.12 Prior to Unit 1 restart * LRA Section B.2.1.12Reactor Vessel * Response toInternals Program Question (4b) dated

May 25, 200513. Flow-Accelerated Include Unit 1 in the program. A.1.14 Prior to Unit 1 restart * LRA Section B.2.1.15

Corrosion Program * Response to GALLaudit Question 144dated October 8,2004

15. Open-Cycle Cooling Include Unit 1 in the program. A.1.16 Prior to Unit 1 restart * LRA Section B.2.1.17Water System * Response to GALLProgram audit Question 144

dated October 8,2004

16. Closed-Cycle Include Unit 1 in the program. A.1.17 Prior to Unit 1 restart * LRA Section B.2.1.18Cooling Water * Response to GALLSystem Program audit Question 144

dated October 8,2004

18. Compressed Air Include Unit 1 in the program. A.1.19 Prior to Unit 1 restart * LRA Section B.2.1.21Monitoring Program

A-18

Page 59: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 2: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(UNIT 1 SPECIFIC)

Item NumberlTitle Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

19. BWR Reactor Water Include Unit 1 in the program. A.1.20 Prior to Unit 1 restart * LRA Section B.2.1.22Cleanup System * LRA Section F.13Program _ _ _

20. Fire Protection Update the Fire Protection Report and to A.1.21 Prior to Unit 1 restart * LRA Section B.2.1.23Program incorporate Unit 1 as an operating unit.Fully implement the program on Unit 1.

21. Fire Water System Update the Fire Protection Report and A.1.22 Prior to Unit 1 restart * LRA Section B.2.1.24Program procedures to incorporate Unit 1 as anoperating unit. Fully implement theprogram on Unit 1.

24. Reactor Vessel Either include Unit 1 within the BWRVIP A.1.25 Prior to the period of * LRA Section B.2.1.28Surveillance ISP, or submit for NRC approval a plant extended operationProgram specific surveillance program that meets

the requirements of 10 CFR 50 AppendixH for the period of extended operation.

Ensure BWRVIP-86-A and BWRVIP-1 16 Prior to the period of * Response to RAIare revised to incorporate Unit 1, and extended operation B.2.1.28-1 datedsubmit to the NRC a license amendment January 31, 2005request to implement the ISP for site-specific use forUnit 1.

25. One-Time Inspection Perform a one-time inspection of the A.1.26 Prior to Unit 1 restart * Response to RAIProgram ASME equivalent Class MC supports in a B.2.1.33-2(b) datedsubmerged environment of the Unit 1 January 18, 2005Torus.

34. Environmental Include Unit 1 in the program. A.1.35 Prior to Unit 1 restart * LRA Section B.3.1QualificationProgram _ _ _ ___

A-19

-

Page 60: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 2: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMS AND TLAAs(UNIT I SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

47. Open Item 01 2.4-3 Perform one time confirmatory UT N/A Prior to Unit I restart * Enclosures 1 and 9 ormeasurements on the drywell vertical TVA letter datedcylindrical area immediately below the November 16, 2005drywell flange

49. Unit 1 Periodic Develop and implement new program. A.2.4 Prior to Unit 1 restart * Response toInspection Program Proposed Unresolved

Items 3.0-2 LP (1 &2) and 3.0-3 LP datedMay 27, 2005

* Enclosure 1 of TVAletter datedSeptember 14, 2005

* Enclosure 1 of TVAletter dated April 4,2006

Develop and submit implementing Prior to Unit 1 restart * Response toprocedure(s) for NRC review. Proposed Unresolved

Items 3.0-4 LP datedMay 27, 2005

* Enclosure 1 of TVAletter dated April 4,2006

A-20

Page 61: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 2: BFN COMMITMENT LIST ASSOCIATED WITH LRA APPENDIX A AGING MANAGEMENT PROGRAMSAND TLAAs

(UNIT I SPECIFIC)

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)63. Response to NRC Replace all BFN Unit 1 dry tubes. N/A Prior to Unit 1 restart * Response toQuestions Question (8) datedConcerning RPV May 25, 2005Internals

Perform MSIP for Unit 1 Control Rod Drive Prior to Unit 1 restart * Response toReturn Line Cap. Question (6) dated

May 25, 2005Change the Unit 1 AHCs to bolted design. Prior to Unit 1 restart * Response to NRC

Question (7) dated__ May 25, 2005

A-21

Page 62: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 3: UNIT 1 RESTART COMMITMENTS THAT ARE DISCUSSED IN LRA APPENDIX F

NOTE: See Note at the beginning of Table 2

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ (L FSA R )

50. Appendix F.1 Evaluate and modify, as required, main N/A Prior to Unit 1 restart * LRA Appendix Fsteam leakage path piping to ensure * TVA response datedstructural integrity. January 31, 2005

* TVA response datedMarch 2, 2006

51. Appendix F.2 Implement Containment Atmosphere N/A Prior to Unit 1 restart * LRA Appendix FDilution System modification. * TVA response dated

January 31, 2005* TVA response dated

March 2, 200652. Appendix F.3 Revise Fire Protection Report per Unit 1 N/A Prior to Unit 1 restart * LRA Appendix F

License Condition 2.C.13. * TVA response datedJanuary 31, 2005

* TVA response datedMarch 2, 2006

* TVA response datedApril 21, 2006

53. Appendix F.4 Implement Environmental Qualification N/A Prior to Unit 1 restart * LRA Appendix FProgram. * TVA response dated

January 31, 2005* TVA response dated

March 2, 200654. Appendix F.5 Address GL 88-01, and make necessary N/A Prior to Unit 1 restart * LRA Appendix F

plant modifications. * TVA response datedJanuary 31, 2005

* TVA response datedMarch 2, 2006

A-22

Page 63: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 3: UNIT I RESTART COMMITMENTS THAT ARE DISCUSSED IN LRA APPENDIX F

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)55. Appendix F.6 BWRVIP Programs used for Units 2 and . NIA Prior to Unit 1 restart. * APS ^.Appcnd.x F

will be used for Unit 1. * TVA response datedJanuary 31, 2005

* TVA response datedMarch 2, 2006

56. Appendix F.7 Install ATWS features. N/A Prior to Unit 1 restart * LRA Appendix F* TVA response dated

January 31, 2005* TVA response dated

March 2, 200657. Appendix F.8 Remove Reactor Vessel Head Spray N/A Prior to Unit 1 restart * LRA Appendix F

piping in drywell, and seal the primary * TVA response datedcontainment penetrations January 31, 2005

* TVA response datedMarch 2, 2006

58. Appendix F.9 Implement the Hardened Wetwell Vent N/A Prior to Unit 1 restart a LRA Appendix Fmodification. * TVA response dated

January 31, 2005* TVA response dated

March 2, 200659. Appendix F.10 Cap Service Air and Demineralized Water N/A Prior to Unit 1 restart * LRA Appendix F

Primary Containment Penetrations. * TVA response datedJanuary 31, 2005

* TVA response datedMarch 2, 2006

A-23

Page 64: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

TABLE 3: UNIT I RESTART COMMITMENTS THAT ARE DISCUSSED IN LRA APPENDIX F

Item Number/Title Commitment LRA Implementation SourceAppendix A Schedule

(UFSAR)

60. Appendix F. 11 Modify Auxiliary Decay Heat Removal N/A Prior to Unit I restart * LRA Appendix FSystem to serve Unit 1. * TVA response dated

January 31, 2005* TVA response dated

March 2, 200661. Appendix F.12 Fully implement the Maintenance Rule N/A Prior to Unit 1 restart * LRA Appendix F

Unit 1's temporary exemption ceases to * TVA response datedbe effective. January 31, 2005

* TVA response dated__ March 2, 2006

62. Appendix F.13 Replace RWCU piping outside of primary N/A Complete * LRA Appendix Fcontainment with IGSCC resistant piping. * TVA response dated

January 31, 2005Implement actions requested in GL 89-10 * VA response datedfor RWCU March 2, 2006

A-24

Page 65: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

APPENDIX B

CHRONOLOGY

This appendix contains a chronological listing of the routine licensing correspondence betweenthe U.S. Nuclear Regulatory Commission (NRC) staff and the Tennessee Valley Authority(TVA), and other correspondence regarding the NRC staff's reviews of the Browns FerryNuclear (BFN), Units 1, 2, and 3 (under Docket Numbers 50-259, 50-260 and 50-296) licenserenewal application (LRA).

November 7, 2005

November 28, 2005

December 20, 2005

January 31, 2006

January 31, 2006

February 14, 2006

March 1, 2006

March 2, 2006

Letter from Harold 0. Christensen, NRC, to K. W. Singer, TennesseeValley Authority (TVA) regarding Browns Ferry Nuclear Plant - InspectionReport 05000259/2005013, 05000260/2005013, and 05000296/2005013(Accession No. ML053120402)

Response to Advisory Committee on Reactor Safeguards (ACRS) -Interim Report on the Safety Aspects of the License Renewal Application(LRA) for Browns Ferry Nuclear Plant, Units 1, 2, and 3. (Accession Nc.ML053180460)

TVA letter to NRC, "Browns Ferry Nuclear Plant (BFN) - SupplementalInformation for the Time Limited Aging Analysis of the Relaxation of theCore Hold-Down Bolts and the Unit 1 Periodic Inspection Program (TAONOS. MCI 704, MC1705, AND MC1706) (Accession No. ML05356032E)

Browns Ferry Nuclear Plant, Units 1, 2, and 3 License RenewalApplication - Annual Update Letter (Accession No. ML060410288)

Safety Evaluation Report related to the License Renewal Application ofBrowns Ferry Nuclear Plant, Units 1, 2, and 3 - Request for AdditionalInformation Related to Appendix F items in the Application. (AccessionNo. ML060330295)

TVA letter to NRC, 'Browns Ferry Nuclear Plant (BFN) Units 1, 2, and 3License Renewal Application - Revised Commitment Tables" (AccessionNo. ML060450582)

Memorandum to James E. Dyer, Director of Nuclear Reactor Regulationfrom William D. Travers, Regional Administrator, regarding Browns FerryLicense Renewal Application. (Accession No. ML060610326)

TVA letter to NRC, "Browns Ferry Nuclear Plant (BFN) Units 1, 2, and ,License Renewal Application - Request for Additional Information relatedto Appendix F of the License Renewal Application: Integration of BFNUnit 1 Restart and License Renewal Activities" (Accession No.ML0606106100)

B-1

Page 66: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

March 3, 2006

March 7, 2006

March 7, 2006

March 23, 2006

April 4, 2006

April 21, 2006

Safety Evaluation Report related to the License Renewal Application ofBrowns Ferry Nuclear Plant, Units 1, 2, and 3 - Request for AdditionalInformation Related to Appendix F items in the Application and TopicsDiscussed in Public Meeting on March 1, 2006, at the Nuclear RegulatoryCommission. (Accession No. ML0606203530)

TVA letter to NRC, "Browns Ferry Nuclear Plant (BFN) Units 1, 2, and 3License Renewal Application - Periodic Inspection Program"(Accession No. ML060660374)

TVA letter to NRC, "Browns Ferry Nuclear Plant (BFN) Units 1, 2, and 3License Renewal Application - Supplemental Information for Open Item2.4-3. (Accession No. ML060790376)

Letter from Dr. Graham B. Wallis, ACRS Chairman, to Honorable Nils J.Diaz, NRC Chairman. Report on the Safety Aspects of the LicenseRenewal Application for the Browns Ferry Nuclear Plant Units 1, 2, and 3.(Accession No. ML060870208)

TVA letter to NRC, "Browns Ferry Nuclear Plant (BFN) Units 1, 2, and 3License Renewal Application - Unit 1 Lower Drywell Liner Inspections,Unit 1 Periodic Inspection Program, and Residual Heat Removal ServiceWater Piping Inspections (TAC NOS. MC1704, MC1705, AND MC1706(Accession No.ML060950060)

TVA letter to NRC, "Browns Ferry Nuclear Plant (BFN) Units 1, 2, and 3License Renewal Application - Revised Commitment List (TAC NOS.MC1704, MC1705, AND MC1706)

B-2

Page 67: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

APPENDIX CPRINCIPAL CONTRIBUTORS

RESPONSIBILITYNAME

R. SubbaratnamY. Diaz :SanabriaR. KarasD. JengH. AsharK. ManclyY.LiR. McNallyM. Hart-zmanC. JulianL. LundA. Hododon

Project ManagerProject ManagerManagement SupervisionCivil EngineeringCivil EngineeringManagement SupervisionTechnical Support: Mechanical EngineeringMechanical EngineeringMechanical EngineeringRegional SupportManagement SupervisionOffice of General Counsel

C-1

Page 68: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

I

Page 69: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

NRC FORM 335 U.S. NUCLEAR REGULATORY COMMISSION 1. REPORT NUMBER(9-2004) (Assigned by NRC. Add Vol., Supp., Rev.,NRCMD 3.7 and Addendum Numbers, N yny.)

BIBLIOGRAPHIC DATA SHEET(See istnuctions on the revere) NUREG-1843, Supp. 1

2. TITLE AND SUBTITLE 3. DATE REPORT PL BLISHED

Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, MONTH YEARUnits 1, 2, and <, Supplement 1 April 2006

4. FIN OR GRANT NUMBER

S. AUTHOR(S) 6. TYPE OF REPORT

Yoira Diaz SanabriaRam Subbaratnam

7. PERIOD COVERED (indoLsm Dates)

8. PERFORMING ORGWNIZATION -NAME AND ADDRESS (INRC, provide DOeon. Offc or Rgion, U.S. Nuclear RegulatotyCommisain. andmahingaddress :cont-actrpmvide nam arsnd maig address.)

Division of License RenewalOffice of Nuclear Reactor RegulationU.S. Nuclear Regulatory CommissionWashington, DC 20555-0001

9. SPONSORING ORGANIZATION - NAME AND ADDRESS (IfNRC, typo 'Same as above'; itcontractor, provide NRCDtsiovn, Oft corRegion. U.S. NuarRegubttorylnmisdon,and maftg adress.)

Same as above

10. SUPPLEMENTARY NOTES

11. ABSTRACT (200 wslids orless)

This document is a supplemental safety evaluation report (SSER) on the application for license renewal for the Browns. FerryNuclear Plant (13FN), as filed by Tennessee Valley Authority (TVA or the applicant). By letter dated December31, 2003, TVAsubmitted its application to the U.S. Nuclear Regulatory Commission (NRC or the Commission) for renewal of the BFNoperating licenses for an additional 20 years. The NRC staff (the staff) issued a safety evaluation report (SER), dated January12, 2006, which summarizes the results of its safety review of the renewal application for compliance with the requirements ofTitlel0, Part54, of the Code of Federal Regulations, (1OCFRPart54), 'Requirements for Renewal of Operating Licenses forNuclear Power Plants."

During the 530th full committee meeting of the Advisory Committee on Reactor Safeguards, March9, 2006, the Committeereviewed the license renewal application (LRA) for BFN Units1, 2, and 3. The staff had closed the open items with acommitment to issue a supplemental safety evaluation report (SSER) that addresses the Committee's review comments on theSER. This SSER addresses the Committee's concerns and includes revisions and enhancements to the following agingmanagement programs (AMPs): (1) Unitl Periodic Inspection Program (B.2.1.42), (2) ASME SectionXI Subsection WI:Program (B.2.1.32), and (3) Open-Cycle Cooling Water System Program (B.2.1.17). This supplement also addresses theCommittee's other concerns as documented in its final letter report dated March23, 2006.

12. KEY WORDS/DESCRIPTORS (List words orphrases that wit assist researchers in locatig the report) 13. AVAILABILITY STATEMENT

license renewal, nuclear power unlimited14. SECURITY CLA!ZIFICATION

(This Page)

unclassified(This Report)

unclassified15. NUMBER OF PAGES

16. PRICE

_ _SNRC FORM 335 (9-2004) PRINTED ON R �-CYCLED PAPER

Page 70: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

Federal Recycling Program

Page 71: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

II--

Page 72: NUREG-1843, Supp 1, 'Safety Evaluation Report …NUREG-1843 Supplement 1,I Safety Evaluation Report Related to the License Renewal of the Browns Ferry Nuclear Plant, Units 1, 2, and

NUREG-1843, Supp. 1 SAFETY EVALUATION REPORT RELATED TO THE LICENSE RENEWAL OFTHE BROWNS FERRY NUCLEAR PLANT, UNITS 1, 2, AND 3

APRIL 2006