715.4A300May 29, 2007(Sup. 1/30/02)
Maximum Allowable Flange LoadsAxial Flow
Terms:Fx, Fy, Fz Applied suction and discharge forces as
shown in Figure 1, units in lbs.Mx, My, Mz Applied suction and discharge moments as
shown in Figure 1, units in ft.lbs.Fmax, Mmax Max. allowable resultant loads,
See Table 1 for AF sizes.Loads applied to suction and discharge flanges must meetthe following criteria:
Maximum Allowable Flange LoadsAxial Flow
AF PumpSize
Suction & Discharge Suction & Discharge
Fmax. (lb)Mmax. (ft
lb) Fmax. (N)Mmax.(Nm)
6" 1115 2123 4960 28798" 1679 4201 7469 5696
10" 2382 7475 10,596 10,13512" 2916 10,953 12,972 14,85114" 3210 13,312 14,279 18,05016" 3682 17,654 16,379 23,93718" 4153 22,405 18,474 30,78920" 4624 27,835 20,569 37,74124" 5566 40,462 24,760 54,862
700mm 5566 40,462 24,760 54,86230" 6980 63,822 31,050 86,53636" 8394 92,481 37,340 125,39442" 9808 126,442 43,630 171,441
1200mm 11,221 165,710 49,915 224,68454" 21,440 361,900 95,374 490,696
copyright Goulds Pumps, Incorporated, a subsidiary of ITT Corporation , Inc. Page 4 of 9