8
November 8, 2005 JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4 – 1.2 mm) Higher granularity requires more anodes More anodes require more resistive network and/or more acquisition channels Need optimal readout electronics and data acquisition system

November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

Embed Size (px)

Citation preview

Page 1: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

New Instrumentation for JLAB Awake Animal Project

• Smaller Pixel Size requires higher granularity in PMT (2.4 – 1.2 mm)

• Higher granularity requires more anodes• More anodes require more resistive network

and/or more acquisition channels• Need optimal readout electronics and data

acquisition system

Page 2: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

Two Options for Readout Electronics of 10 cm X 20 cm Gamma-Camera

BB

CC DD

AA

Resistive Network Resistive Network with 4 Output with 4 Output Channels per Channels per

ModuleModule

4 Output Channels 4 Output Channels X 8 Modules = 32 X 8 Modules = 32

Channels TotalChannels Total

8 Rows and 8 8 Rows and 8 Columns with 16 Columns with 16 Output ChannelsOutput Channels

32 Output 32 Output Channels X 2 Channels X 2 Modules = 64 Modules = 64 Channels totalChannels total

Each Module Each Module Read Out Read Out SeparatelySeparately

2x2 Modules 2x2 Modules Read Out in Read Out in SeriesSeries

Type IType I Type IIType II

Page 3: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

Raw Image showing four Hamamatsu 8500 tubes (each tube 5 cm square)

Raw Image Summed in Y-Dimenision Showing High-Contrast and Spatial Uniformity

10 cm X 10 cm Gamma-Camera Built for Deutsches Krebsforschungszentrum

(German Cancer Research Center)

Gamma Camera Components

Page 4: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

Dual Modality Gamma/Optical Imager Deutsches Krebsforschungszentrum

(German Cancer Research Center)

Gamma/Optical System on Tomographic Gantry

Tc-99m MDP Bone ScanPlanar, Pinhole Collimator

Page 5: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

New 10 cm X 20 cm Gamma-Camera for John Hopkins University Awake Animal Imager

Composed of Two Modules Like the 10 cm X 10 cm Gamma-Camera Made for the Deutsches

Krebsforschungszentrum

Page 6: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

New 10 cm X 20 cm Gamma-Camera for John Hopkins University Awake Animal Imager

Image Showing Two Modules of 4 Tubes

Close-Up of Central Region Showing Pixel Resolution in Crack Between Tubes of Different Modules

Module 2Module 2

Module 1Module 1

Page 7: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

Resistive Network with Four Readout Channels

DC

BA

.

.

.

.

.

.

.

.

.

.......

.....

.....

.....

.....

.......

.

.

.

.

.

.

R'R'

R'R' R'

R'

R1 R2 R3 R31 R32

R1' R2' R3' R31' R32'

A A A

A A A AA

AA

A A

A AAAA

AAA

R1.5k

R1.5k

R1.5k

110

30 30 30

R1.5k

R1.5k

110

110

30

R1.5k

R1.5k

R1.5k

R1.5k

R1.5k

30110

30

1.2 mm step CsI(Tl) crystal with 22Na source

Resistive Network used to read out 1024 channels of

Burle 85021 PMT using four readout channels Lineout of Image Showing

High-Contrast Pixel Separation

Page 8: November 8, 2005JLAB Awake Animal Project New Instrumentation for JLAB Awake Animal Project Smaller Pixel Size requires higher granularity in PMT (2.4

November 8, 2005 JLAB Awake Animal Project

Readout Data Acquisition System

• PCI Based System– Two 16 channel Datel PCI416 cards in the current two

detector / 16 channel per detector system

– Two 32 Channel Datel PCI417 needed for next 64 channel detector (type 2)

– One 32 Channel Datel PCI417 needed for next 32 channel detector (type 1)

• VME Based System– Capable of modules of 64 channels

• USB Based System– Capable of modules of 128 channels