17
U.S. ENVIRONMENTAL PROTECTION AGENCY Office of Pesticide Programs Antimicrobials Division (7510C) 1200 Pennsylvania Avenue NW Washington, D.C. 20460 NOTICE OF PESTICIDE: x Registration Reregistration (under FIFRA, as amended) Name and Address of Registrant (include ZIP Code) : EPA Reg. Number: 71240-6 Date of Issuance: gO 2009 Term of Issuance: Conditional Name of Pesticide Product: PERMA-GUARD MOLD AND MILDEW PROOF INTERIOR COATING On the basis of information furnished by the registrant, the above named pesticide is hereby registered/reregistered under the Federal Insecticide, Fungicide and Rodenticide Act. Registration is in no way to be construed as an endorsement or recommendation of this product by the Agency. In order to protect health and the environment, the Administrator, on his motion, may at any time suspend or cancel the registration of a pesticide in ",ccordance with the Act. The"acceptance of any name in connection with the registration of a product under this Act is not to be construed as giving the registrant a right to exclusive use of the name or to its use if it has been covered by others. This product is conditionally registered in accordance with FIFRA sec 3(c)(7)(A) provided that you: 1. Submit and/or cite all data required for registration of your product under FIFRA sec. when the Agency requires all registrants of similar products to submit such data; and submit acceptable responses required for re-registration of your product under FIFRA section 4. 2. Make the labeling changes listed below before you release the product for shipment: a. Revise the "EPA Registration Number to read, "EPA Reg. No. 71240-6". 0/ Product Manager Team-33 Regulatory Management Branch I Division (7510P) EPA Form 8570-6 Date:

NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

U.S. ENVIRONMENTAL PROTECTION AGENCY

Office of Pesticide Programs Antimicrobials Division (7510C) 1200 Pennsylvania Avenue NW

Washington, D.C. 20460

NOTICE OF PESTICIDE: x Registration

Reregistration

(under FIFRA, as amended)

Name and Address of Registrant (include ZIP Code) :

EPA Reg.

Number:

71240-6

Date of

Issuance:

~EP gO 2009 Term of Issuance:

Conditional

Name of Pesticide Product:

PERMA-GUARD MOLD AND MILDEW PROOF INTERIOR COATING

On the basis of information furnished by the registrant, the above named pesticide is hereby registered/reregistered under the Federal

Insecticide, Fungicide and Rodenticide Act.

Registration is in no way to be construed as an endorsement or recommendation of this product by the Agency. In order to protect

health and the environment, the Administrator, on his motion, may at any time suspend or cancel the registration of a pesticide in

",ccordance with the Act. The"acceptance of any name in connection with the registration of a product under this Act is not to be

construed as giving the registrant a right to exclusive use of the name or to its use if it has been covered by others.

This product is conditionally registered in accordance with FIFRA sec 3(c)(7)(A) provided that you:

1. Submit and/or cite all data required for registration of your product under FIFRA sec. ~(c)(5) when the Agency requires all registrants of similar products to submit such data; and submit acceptable responses required for re-registration of your product under FIFRA section 4.

2. Make the labeling changes listed below before you release the product for shipment:

a. Revise the "EPA Registration Number to read, "EPA Reg. No. 71240-6".

Si_fjQ";:;~i// Marsha~1I 0/ Product Manager Team-33 Regulatory Management Branch I ~ntimicrobials Division (7510P)

EPA Form 8570-6

Date:

Page 2: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

Page 2 EPA Registration No. 71240-6

b. Include the following statement to the "Precautionary Section" to read:

"Wear long sleeved shirt and long pants, socks, shoes and chemical resistant gloves. A respirator with an organic-vapor removing cartridge with a prefilter approved for pesticides (MSHAINIOSH approval number prefix TC-23C), or a canister approved for pesticides (MSHAINIOSH approved number prefix TC-

o 4G), or a NIOSH approved respirator with an organic vapor (OV) cartridge or canister with any R, P or HE prefilter.

c. Revise the "Container Disposal" statements to be in agreement with PR Notice 2007-4.

d. The 1 st claim on page 4 must be brought into compliance with PR Notice 2000-1, Treated Article" by deleting the second and third "[OPTIONAL]." The claim must read "This product contains an antimicrobial that will kill mold, mildew, and stain/odor causing bacteria remaining on the surface at the time of application .. "

e. The 5th, 6th, 8th, 9th, 10th, 12th, and 14th claims on page 4 must be brought into compliance with PR Notice 2000,.1 , Treated Article by qualifying the type of bacteria controlled by your product. You must revise these claims to read " .... stain and odor causing bacteria."

f. Revise the first paragraph under "Perma-Guard Advantage" on page 6 by deleting the 1st, 2nd, and 3rd "[OPTIONAL]s" to bring it into compliance with PRN 2000-1.

g. Revise the last statement in the second paragraph under "Perma-Guard Advantage" on page 6 by deleting the 2nd "[OPTIONAL]" to bring it into compliance with PRN 2000-1.

h. Incorporate the EPA Registration Numbers for the registered product, JOMAX Mold Killer and Deodorizer, on pages 6,8, and 12. (You need to add the Registration Numbers to the statement)

i. Delete·the 2" [OPTIONAL]s" under "Limitations" on page 7,9, and 13.

j. Delete the 4th "[OPTIONAL]" under "limited Warranty" on pages 7 and 9 to bring it into compliance with PR N 2000-1.

Page 3: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

) )

Page 3 EPA Registration No. 71240-6

k. Revise the statement, "A high performance EPA registered acrylic interior paint," on pages 8 and 11 by deleting the phrase, "EPA registered."

I. Revise the third statement in the first paragraph on page 8 by deleting the 2nd "[OPTIONAL], such that statement is in agreement with PR Notice 2000-1.

m. Revise the ANTIMICROBIAL section on pages 8 and 11 by deleting all the "[OPTIONAL]s" and the phrase "of these organisms to bring it into compliance with PRN 2000-1.

n. Revise the 1st statement under the third paragraph on pages 8 and 11 by deleting the 1st "OPTIONAL" to bring it into compliance with PRN 2000-1.

o. Delete the claims, "PERM Guard passes severe testing following ASTM 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial Resistance testing following ATCC Method 147" on pages 8 and 11. Data was not submitted to support either claim.

p. "Recommended Coverage" phrase on pages 9 and 13 must be brought into compliance with PR Notice 2000-5, Mandatory Labeling by deleting the term, recommended.

q. The proposed alternate brand names cited on page 1 of the label are acceptable.

r. On page 13 delete the claim" [optional] note: Perma-Guard is formulated with a ... Iead compounds."

3. Submit two (2) copies of your final printed labeling before distributing or selling the product bearing the revised labeling.

If these conditions are not complied with, the registration will be subject to cancellation in accordance with FIFRA sec. 6(e). Your release for shipment of the product constitutes acceptance of these conditions.

Page 4: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

Page 4 EPA Registration No. 71240-6

A stamped copy of the label is enclosed for your records.

If you have any questions concerning this Notice of Registration, please contact Martha Terry at (703) 308-6217.

Enclosure: (Stamped Label)

Sincerely,

~~/~ Product Manager 33' 'Regulatory Management Branch I Antimicrobials Division (7510P)

Page 5: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

) PERMA-GUft )- Volume 1 - Page 49 of 1 oo~ '1 PERMA-GUARD® Mold & Mildew Proof Interior Coating GENERAL LANGUAGE

PERMA-GUARO® Mold & Mildew Proof Interior Coating

ADDITIONAL BRAND NAMES PERMA-GUARO® Mold & Mildew Proof Bathroom Paint

PERMA-GUARO® Mold & Mildew Proof Ceiling Paint PERMA-GUARD® Bathroom Paint

PERMA-GUARD® Interior Paint PERMA-GUARD® Interior Coating ACCEPTED

PERMA-GUARO® Ceiling Paint V'f:.th CONTMENTS Mold Shield™ Mold & Mildew Proof Bathroom Paint 'EPA Letter D2.i::3d:

Mold Shiel'd™ Mold & Mildew Proof Interior Paint Mold Shield™ Mold & Mildew Proof Ceiling Paint SEP 3 0 ~.

Mold Shield™ Bathroom Paint Under ~>.~.: F~;d.G·~·:·J I-::1sr:·Gti·ci~.~9.

Mold Shield ™ Interior Paint rtmg:.c~di~. C:C~;.: ~;.00_':;;~'i.'(;;·-.le Act El~ Mold Shield™ Ceiling Paint amendGd,':fo:·:;.hc p;'."Bi:icide,

PERMA-WHITE® Mold & Mildew Proof Bathroom Painfeg"lsi6red u'uder BPli Reg-. No. PERMA-WHITE® Mold & M!ldew Proof Int~~ior Pa~nt I-tId-lfO-~ PERMA-WHITE® Mold & Mildew Proof Celhng Paint I .' .

PERMA-WHITE® Bathroom Paint PERMA-WHITE® Interior Paint PERMA-WHITE® Ceiling Paint

Interior Latex Paint with Mildewcide

( . ,

• , <

, :

I '(, ,

...

Active Ingredient 4,5-Dichloro-2-n-octyl-3(2H)-isothiazolone

Other Ingredients 0.07%

99.03% 100.00%

< "

, ,. Total

KEEP OUT OF REACH OF CHILDREN

CAUTION

See side/Back panel for additional Precautionary Statements

FIRST AID If inhaled - Move person to fresh air

- If person is not breathing, call 911 or an ambulance, then give artificial respiration, preferably mouth-to-mouth if possible

- Call a poison control center or doctor for further treatment advice If on skin - Take off contaminated clothing

- Rinse skin immediateht, with plenty of water for 15-20 minutes

April 8, 2009 Page 1 of 13

Page 6: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

c:

\~J PERMA-GUAr-""-· Volume 1 - Page 50 of 100 PERMA-GUARO® Mold & Mildew Proof Interior Coating . ) GENERAL LANGUAGE

- Call a poison control center or doctor for treatment advice If -' Call a poison control center or doctor immediately for treatment advice swallowed - Have person sip a glass of water if able to swallow

- Do not induce vomiting unless told to by a'poison control center or doctor

- Do not give anything to an unconscious person If in eyes - Hold eye open and rinse slowly and gently with water for 15-20

minutes. Remove contact lenses, if present, after the first 5 minutes, then continue rinsing.

- Call a poison control center or doctor for treatment advice . Have the product container or label with you when calling a poison control center or

doctor or going for treatment advice.

EPA Reg. No. 71240-EPA Est. No.

. Net Contents: ZINSSER Logo Made in U.S.A.' RPM Logo www.zinsser.com

Rust-Oleum Corporation 11 E Hawthorn Pkwy. Vernon Hills, IL 60061

B-I-N, BULLS EYE [Opt], BULLS EYE 1-2-3 [Opt], JOMAX, PERMA-GUARD and the ZINSSER Bulls Eye design are registered trademarks of ZINSSER. READY PATCH is a trademark of ZI NSSER.

PRECAUTIONARY STATEMENTS HAZARD TO HUMANS AND DOMESTIC ANIMALS .

Caution. Harmful if inhaled, swallowed, or absorbed through skin. Avoid breathing spray mist or vapors. Avoid contact with skin, eyes, or clothing. Do not use in confined space without proper ventilation. Wash thoroughly with soap and water after handling

. and before eating, drinking, chewing gum, or using tobacco or using the toilet. Remove

. and wash contaminated clothing before reuse.

When applying with a sprayer, applicator should use a R-series filter if the respirator is to be used for not more than one shift and a P-series filter if it is to be used for more than one shift.

STORAGE AND DISPOSAL llCCEPTED

with COMIVTENTS [For sizes one gallon or less] • EFA. LIE-Her Dated: 'Store in original container in areas inaccessible to children. Do not store on side. ~~p 3 0 200'1'\ not reuse empty container. Discard in. trash or recycle. ::I

.[For sizes greater than one gallon] Do not contaminate water, food or feed by storage or disposal.

April 8, 2009 Page 2 of 13

Page 7: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

--) -, 1ot\1 . PERMA-GUAr- ') Volume 1 - Page 51 of 100

PERMA-GUARO® Mold & Mildew Proof Interior Coating .. GENERAL LANGUAGE

Pesticide Storage: Do not store or apply in extreme temperatures. Close container after each use.

Pesticide Disposal: State or local hazardous waste regulations may apply if there are different from Federal regulations. Wastes resulting from the use of this product may be disposed of on site or at an approved waste disposal faCility.

Container Disposal: Triple rinse (or equivalent). Then offer for recycling or reconditioning or puncture and dispose of in a sanitary landfill or, if allowed by state and locate authorities by burning. If burned, stay out of smoke.

P"CCEPTED op .... ,i1'1., C.O~·rv'f·i\Jn::r.J~S 'Vic. .. ~..!. .. _f' ",.'.!. .......... ,.-~ .... , .•

'.,' EPI'I Let~t2:r Dat8~1:

April 8, 2009 Page 3 of 13

Page 8: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

',.J PERMA-GUAf"-""'· Volume 1 - Page 52 of 100 CO ~\ 1 PERMA-GUARD® Mold & Mildew Proof Interior Coating -) GENERAL LANGUAGE

GENERAL MARKETING LANGUAGE

[OPTIONAL]This product contains an antimicrobial that will kill mold, mildew and [Q!!t nQ:st~in~dor-cau~,ing ba~eria {fljw ' ... remaining on the surfaCe at the time of applicatiol'\r.~vm pre~fj(" Fe gk'Wt!""':U::J~aiJ:JIW st:t1f2e.

[Optional] Lifetime Durability Guarantee [Optional] 5 YEAR Mold & Mildew-Proof Paint Film Guarantee [Optional] 10 YEAR Mold & Mildew-Proof Paint Film Guarantee [Optional] 5 YEAR Mold & Bacteria-Proof Paint Film Guarantee [Optional] 10 YEAR Mold & Bacteria-Proof Paint Film Guarantee

[Optional] Mold & Mildew-Proof [Optional] Mold & Bacteria-Proof

, [Optional] Mold, Mildew & Bacteria-Proof [Optional] Mold, Mildew & Bacteria Killer* [Optional] Mold & Mildew Killer [Optional] Kills Bacteria* [Optional] Kills Stain & Odor causing Bacteria [Optional] Kills Mold, Mildew and Bacteria* [Optional] Mold and Mildew Resistant

· [Optional] Interior Paint [Optional] Interior Coating [Optional] Ceiling Paint [Optional] Ceiling Coating [Optional] Bathroom Paint [Optional] Bathroom Coating [Optional] Antimicrobial Coating [Optional] Antimicrobial Paint

[Optional] Washable · [Optional] Scrubbable [Optional] Stain-Resistant [Optional] Durable

[Optional] Withstands Moisture · [Optional] Moisture Resistant [Optional] Provides extra protection in high humidity areas

[Optional] Easy Application [Optional] Fast Drying ,[Optional] Self-Priming · [Optional] Superior Adhesion ,[Optional] Great Hide [Optional] Good Hide

April 8, 2009

A_CCEPTED 'vvith COMMENTS

EE.!\. Lettsy Dated;

SEP a 0 2009

Under the Federal Insecticide, F\mglclC!'.~, ann Eodenticide Ai::t as (\xnended, for the pesticide,

xegii{~~ ~eg. No.

Page 4 of 13

Page 9: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

(

.:) PERMA-GUArl Volume 1 - Page 53 of 100 qof\l PERMA-GUARD® Mold & Mildew Proof Interior Coating , .' GENERAL LANGUAGE

[Optional] Latex Acrylic, , [Optional] Water Based, [Optional] Eggshell [Optional] Satin [Optional] Semi-Gloss

[Optional] White [Optional] (Tintable) [Optional] (Low Odor) [Optional] LOW VOC's

[Optional] Formulated with Mold & Mildew Proof Technology

* Controls bacteria that cause stains and odors.

Container Sizes 31.5 fl. oz. (1 pt. 15.50 oz.l931 ml) 126 fl. oz. (3.94 Qts.l3.72L)

, 378 fl. oz. (2.90 Gals.l11.16L) 630 fl. oz. (4.92 Gals/18.62L)

AprilS, 2009

_\ 1 Insecticide, Fi1d,,:.rthE, F'etl1;:rr:'.. "'-, 'do l{"'+as ~) "'. ,v' f~'1t1Ci e nu-l:,.. (J1C1Ci<.> ;' \ te'. C·.Uo.~I, : Ln, - -,. .", . . le 2J~H;nded, 10; [I \E~ )~eSURC1C , 'No

, '\- ~ cpl' eo., , • "'- steTI"f' UPQ.C!.\..> '). '" •

re~l 11 ~tf()-~

Page 5 of 13

Page 10: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

(

I,':J PERMA-GUAr---· Volume 1 - Page 54 of 100 \()~ \ l PERMA-GUARD® Mold & Mildew Proof Interior Coating .) CONSUMER LANGUAGE '

OPTIONAL CONSUMER MARKETING LANGUAGE

The PERMA-GUARD® Advantage: PERMA-GUARD is a high performance EPA registered, latex acrylic paint formulated to provide a beautiful, long-lasting finish and to kill mold, mildew and~ stain and odor-causing bacteria ~remaining on the painted s-urface~at the time of application and is GUARANTEED to prevent the growth of mold & mildew and [Optional] stain and odor-causing bacteria for [Optional] FIVE YEARS [Optional] TEN YEARS. It produces a tough, [Optional] scrubbable [Optional] washable finish with a LIFETIME DURABILITY GUARANTEE to resist fading, peeling and blistering (see warranty).

Great for all interior surfaces! PERMA-GUARD is ideal for new or previously painted ~rywall, cured plaster or masonry, tile, w~od - ceilings, walls, and trim as well ~~.0t~.BPTED Interior surfaces. Great for Bathrooms, Kitchens, Laundry Rooms, Basement~Y~f(t)~'T.MEN'1"It.'I Ceilings. or any interior area whe~e [Opt~onal] mo~d & milde~ are a concern. ~)r Dat~~: mold, mildew and ~ stain and odor-causing bactena are a concern.·

-\ r 8EP 3 0 200~ . . . DIREC~IONS FO~ USE .'. L;-i~~~~Lhe.F8deralIu~p :~'-l

It IS a violation of Federal Law to use thiS product In a manner InconsIS~rll"wltfr'Jt~t;i i?o'le,~~C1Jcl'l',!~:, I b I· , c..mended, fot iJ' ''',HUCH: E! Act Ci5-a e Ing. f80',isler.1 Ie 1,JOStlclcie ' " .ea Ul1rlp~ 1~p'-,It '

'~'" • .c;, .nneg, No. SURFACE PREPARATION - Surfaces must be clean, sound and free of dirt, dust, '71).. f grease, wax, wallcovering adhesive, soap film, loose paint or other surface II I l{O '\.Q

, contamination. Wash painted areas with an appropriate household cleaning solution and rinse thoroughly. Reinove all existing mold & mildew before painting. Clean surfaces with JOMAX® Mold Killer and Deodorizer and remove stains with Jomax Mold & Mildew Stain Remover. If you are concerned about mold and mildew behind walls, underneath flooring, in ventilation systems or other unseen areas, contact a professional who specializes in mold and mildew remediation.

TWO-COAT SYSTEM- No Priming Required! PERMA-GUARD is self-priming for , most jobs and will adhere to any sound surrace. It bonds to existing glossy paints ..,. even tile and Formica® - without sanding. Fill all nail holes and gouges with ZINSSER READY PATCHTM spackling compound. Spot prime and seal all stains with an appropriate stain killing primer-sealer, such as B-I-N® Primer-Sealer or Bulls Eye® Odorless [Opt] Bulls Eye 1-2-3® [Opt] before painting.

APPLICATION - Shake or stir well before using. Apply with synthetic bristle brush, roller, pad applicator, or sprayer. For airless spraying, use a .017 tip and high medium (2000-2600 PSI) pressure. Apply when air and surface temperatures are 50° - 90°F (10°-32°C) and humidity is less than 80%. May be applied over slightly damp surfaces.

DRY TIME - At normal temperatures, 70°F (21°C), PERMA-GUARD dries to recoat in 2 hours. If used above tile on shower walls, wait at least 24 hours before using shower. Full adhesion and hardness develop in 7 days.

AprilS, 2009 Page 6 of 13

Page 11: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

· ' J PERMA-GUAF.jVO!Ume 1 - Page 55 of 100 \ \(j \1 PERMA-GUARD® Mold & Mildew Proof Interior Coating / ' CONSUMER lANGUAGE

( TINTING - May be tinted to off-white, pastel or medium colors with universal colorants. start with 75% of the tinting formula for a given color and adjust if necessary. Maximum tint - 4 oz. per gallon (31 mill). Multiple containers of tinted paint should be intermixed (boxed) to ensure color uniformity.

(

COVERAGE - Apply each coat at a rate of 400 sq ft (37 m2) per gallon. Coverage will vary with the porosity of the surface am~ the method of application.

CLEANUP - Clean application tools, spatters, and spills immediately with warm water and liquid detergent; rinse with water. Follow equipment manufacturer's directions to clean spray equipment. Remove dried product with a heavy-duty ammoniated household cleaner; rinse with water.

'~LlMITATIONS - Not intended for application to floors or any surface subject to water immersion or prolonged contact with water including shower enclosures, saunas, or steam rooms . .JI)~Not recommended for use in HVAC ductwork.

LIMITED WARRANTY: PERMA-GUARD® [Opti,onal] Mold & Mildew-Proof Interior Paint is guaranteed for [Optio,nal] five [Optional] ten years from the date of application to provide protection of the painted surface from mold, mildew and~stain and odor-causing bacteria when two coats are applied according to the label directions. In addition, the dried paint film is guaranteed for so long as you reside in your home and is made to the original residential consumer paint purchaser to resist fading, peeling and blistering. Application of other paints over PERMA-GUARD® nullifies the warranty. The contents are warranted to be free of defects for two years from date of manufacture. All warranties and guarantees are limited to replacement or refunded value of product actually used when supported by proof of purchase. This guarantee is not transferable. 'Directions are as complete as possible but cannot encompass all conditions, applications, techniques, and/or surfaces which are beyond our control. If you have a question, check with your dealer or call 888-855-1774.

April 8, 2009 Page 7 of 13

Page 12: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

(

- 'J' ~~ I. . PE~MA-GUAr--"') Volume 1 - Page 56 of 100 I I

PERMA-GUARD® Mold & Mildew Proof Intenor Coatmg " j

PROFESSIONAL PAINTER LANGUAGE

OPTIONAL PROFESSIONAL PAINTER MARKETING LANGUAGE [Optional] Great for any Residential or Commercial Project

A high performance~ acry,lic interior paint. PERMA-GUARD [Optional] Satin [Optional] Semi-Gloss [Optional] Eggshell produces a tough, durable, washable finish with a L1FET~ME DURABILITY GUARANTEE to resist fading,

, peeling and blistering (see warranty). )PERMA-GUARD withstands moisture and resists dirt pickup - key conditions that promote mold, mildew and~-stain and odor­causing bacteria growth on the paint film and eventually cause---p£,riffailure. PERMA­GUARD Delivers excellent hide, great touch-up, outstanding adhesion, easy soap and water clean up. It is self-priming, fast drying (recoat in 2 hours), spatter4'esistant and

, has low odor and low VOC's.

ANTIMICROBIAL - PERMA-GUARD will kill mold, mildew and ~stain and odor-causing bacteria ~remaining on the surface at the time of application 'lfte! p~e:c~~~.i~gBn min ted surfaces and will prevent future growth ~ ~ of mold, mildew and~stain and odor-causing bacteria on the pai ted surface only. ~(It does not protect against food borne or disease-causing bacteria).

PERMA-GUARD is guaranteed to prevent the growth of mold, mildew and ~~ stain and odor-causing bacteria on the painted surface for at least [Optional] FIVE [Optional] TEN YEARS. -' ~Ig:: hs::FM

nd 03 ev '"

ACCEPTED Great for all interior surfacesl Ideal for new or previously painted gypsum dl~cflI;:ll~lIViENTS wood, cured plaster and masonry, ceilings, walls, cabinets and trim or previousfY'A .'..J8tter Da,te'.J:' painted metal.' $~IP '!) 0

gU;, <J . 2UL~

DIRECTIONS Unden:re Federal rns8cticic.k

It is a violation of Federal Law to use this product in a manner inconsiste:htwitl1;iitSK1 FodGl1ticido:: 1l.1;( as

I b I, C!,.'I~W .. H:)U, ror. t.he pestICide, a e Ing. "~'gl"t~"ed 'd ~P)!" r-.,;. .».'::;' - lP.1· er .l:..4 'l"l i'i.S£-!, '~O.

,SURFACE PREPARATION - Surfaces must be clean, sound, and free of dirt, dust, 7!~r;o-0 grease, wax, wall covering adhesive, soap film, loose paint or other surface contamination, Remove all existing mold & mildew before painting. Clean surfaces .with Perma-Wash Disinfectant & Fungicide Interior Concentrate, Perma-Wash Fungicide, Disinfectant and Deodorizer Ready-to-Use spray, or' Jomax Mold Killer

, & Deodorizer Ready-to-Use spray. Remove stains with Jomax Mold & Mildew 'Stain Remover. If you are concerned about mold and mildew behind walls, ,underneath flooring, in ventilation systems or other unseen areas, contact a professional who specializes in mold and mildew remediation. For commercial buildings, follow appropriate guidelines for mold removal.

April 8, 2009 Page 8 of 13

Page 13: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

(

I) PERMA-GUAf"'· Volume 1 - Page 57 of 100 \00t \1 PERMA-GUARD® Mold & Mildew Proof Interior Coating . ) PROFESSIONAL PAINTER LANGUAGE

TWO-COAT SYSTEM· No Priming Required! PERMA-GUARD is self-priming and will adhere to any sound surface. It bonds to existing glossy paints - even tile and Formica® - without sanding. The first coat of PERMA-GUARD® primes and seals the surface, providing a base for the topcoat. The topcoat completes the sealing process while providing scrub resistance and protection of the painted surface from mold, mildew and [Optional] stain and odor-causing bacteria. Spot prime and fill all nail holes and gouges with Zinsser READY PATCH

ThO

Spackling & Patching Compound. Seal all stains with an appropriate stain killing primer-sealer, such as B-I-N® Primer-Sealer or Bulls Eye® Odorless [Opt] Bulls Eye 1-2-341> [Opt] before painting.

, APPLICATION - Shake or stir well before using. Apply with synthetic bristle brush roller, pad applicator or sprayer. For airles~ spraying, use a .017 tip and high medium

, (2000-2600 PSI) pressure. Apply when air and surface temperatures are between 50°­gO°F (10°-32°C) and humidity is less than 80%. May be applied over slightly damp surfaces.

DRY TIME - At normal temperatures; 70°F (21 °C) PERMA-GUARD dries to recoat in 2 hours. If used above tile on shower walls, wait at least 24 hours before using shower.

, Full adhesion and hardness develop in7 days.

TINTING - May be tinted to off-white, pastel or medium colors with universal colorants. Start with 75% of the tinting formula for a given color and adjust if necessary. Maximum tint - 4 oz. per gallon (20 oz. per 5 gallon pail). • _', .l!.CC.E'PT7;>

~~:"'I' ""r n, ,1::;.0 tn •. r '-'VWJ'"

.. ~COVERAGE - Apply each coat at a rate of 400 sq. ft. (37m2) p'elf{ LE\~t~~~l\j'TS

g~lIon. Coverage will vary with the porosity of the surface and method of application. "<v~ .Lated:

CLEANUP - Clean a~plication tools, spatters, an~ spills immediately wittJ[,~'<~:' 3 0 20ag and liqUid detergent; nnse wIth water. Follow equIpment manufacturer's$tr-,str01)s.J.91i';~}~',s>~C~C.ich<),

, clean spray equipm~nt. R~move dried product with a heavy-duty ammon~~-WU;~; [~.: ~le }J;~~~~~~~:c~G ii.ct as household cleaner; nnse wIth water. ·~.9.r EPA.R~gJe~~ '. l/ '2 () ~ ,1110.

~. LIMITATIONS - Not intended for application to floors or any surface SUbjec?4 --p to immersion or prolonged contact with water; including shower enclosures, saunas or steam rooms. ~. Not recommended for use in HVAC ductwork.

LIMITED WARRANTY: PERMA-GUARD® [Optional] Mold & Mildew-Proof Interior Paint is guaranteed for [Optional] five [Optional] ten years from the date of application to provide protection of the painted surface from mold, mildew and ~stain and odor-causing bacteria when two coats are applied according to the label directions. [Optional] In addition, the dried paint film is guaranteed for so long as you reside in your home and is made to the original residential consumer paint purchaser to resist ,fading, peeling and blistering. Application of other paints over PERMA-GUARD® nullifies the warranty. The contents are warranted to be free of defects for two years from date of manufacture. This limited warranty is limited to replacement or refunded

April 8, 2009 Page 9 of 13

Page 14: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

(

..J PERMA-GUA("'· Volume 1 - Page 58 of 1 00 ) 40' \ 1 PERMA-GUARD® Mold & Mildew Proof Interior Coating ) PROFESSIONAL PAINTER LANGUAGE

value of product actually used when supported by proof of purchase. If you have a question, check with your dealer or call 888-855-1774.

[Optional] NOTE: ~E~MA-GUARD® is formulated with a mildewcide and does not contain mercury or lead compounds.

April 8, 2009

ACCEPTED •. , r-Ol\IFVI't",\'iTS '-'v'!.hl ,..;.. . i~'llL ·l.~'J

..... EPA LeHr:)r Dated:

l y • SEPe:' 301?nM',u'Cl"''''' ·r..cier Ule l'en81e t.¥.~~. U .. ·;

Fungicide, an::.t Rodenticide Act as ,!''tiended, for the pesticide, re~is:'<ilr€d urLC::':: BPARGg. No.

Page 10 of 13

Page 15: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

( ~.

I .~) PERMA-GUAP-....... j Volume 1 - Page 59 of 100

PERMA-GUARD® Mold & Mildew Proof Interior Coating . j PROFESSIONAL RESTORATION OR REMEDIATION USERS

OPTIONAL PROFESSIONAL RESTORA TIONOR REMEDIATION MARKETING LANGUAGE [Optional] Great for any IAQ Remediation or New Construction Project

PERMA-GUARD [Optional] Mol & Mildew-Proof Interior [Optional] Coating is a high performance . professional [Optional] protective coating; formulated with 100% latex acrylic to provide a long-lasting finish and kill mold, mildew and [Optional] stain and odor-causing bacteria [Optional] on the surface at the time of application and is GUARANTEED to prevent the growth of mold, mildew and [Optional]

: stain and [optional] odor-causing bacteria on the coating film for [Optional] FIVE. [Optional] TEN YEARS. PERMA-GUARD produces a tough, durable, [Optional] satin finish that withstands moisture and resists dirt pickup - protecting and restoring the soundness of new, aged or recoverable water damaged material against mold and moisture. PERMA-GUARD delivers [Optional] great hide, outstanding adhesion, moisture resistance, and easy soap and water clean up. It is low odor, fast drying [Optionall(recoat in 2 hours), spatter-resistant and has low voe's. [Optional] The low sheen finish coat minimizes the appearance of surface imperfections.

ANTIMICROBIAL - PERMA-GUARD will kill mold, mildew and ~ stain and odor-causing bacteri~ remaining on the surface at the time of application ~fter pre-cleaning contaminated surfaces and will prevent future growth~1 ~~of mold, mildew and [Optional] stain and odor-causing bacteria on the painted surface only.~(lt does not protect against food borne or disease-causing bacteria).

PERMA-GUARD [Optional] Protects [Optional] improves the water resistance of wood, concrete and wallboard and minimizes surface water absorption under wet conditions [Optional] (NOTE: rt does not make surfaces waterproof).

Ideal for painting after remediation, [Optional] new construction, [Optional] or ,remodeling [Optional] projects to prevent future mold, mildew and [Optional] stain and odor-causing bacteria growth on the painted surface. Great for attic spaces, interior :wall cavities and crawl spaces on new or previously painted gypsum drywall; wood" trusses, frame and interior side OSS lumber, [Optional] cured plaster and masonry, ,unfinished cement block or pour,ed concrete basements [Optional] previously painted metal and galvanized metal [Optional] and related~alntable surfaces [Optional] and other building materials. ]S,.cCEP -ED

~1\1'<!oh COMMENTS v it .. fP n J. :J.

EPF,.Letter uateo..

SEP 3 0 Z009.

April 8, 2009 Page 11 of 13

Page 16: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

( , "

(

i,-) PERMA-GUAF-'""'· Volume 1 - Page 60 of 100 \W'Ot \1 PERMA-GUARD® Mold & Mildew Proof Interior Coating ) PROFESSIONAL RESTORATION OR REMEDIATION USERS

DIRECTIONS FOR USE It is a violation of Federal Law to use this product in a manner inconsistent with its labeling.

PERMA-GUARD can be used as part of a comprehensive mold remediation or water restoration program. For further information, please refer to the associated "Use of PERMA-GUARD in a Comprehensive Mold REMEDIATION or WATER Restoration Program" pamphlet.

SURFACE PREPARATION - Surfaces must be clean, sound and free of dirt, dust, grease, wax, [Optional] wall covering adhesive, soap film, loose paint or other surface contamination. Remove all existing mold & mildew before painting. Clean surfaces with Perma-Wash Disinfectant & Fungicide Interior Concentrate, Perma-Wash Fungicide, Disiofectant and Deodorizer Ready-to-Use spray, or Jomax Mold Killer & Deodorizer Ready-to-Use spray. Remove stains with Jomax Mol'd & Mildew Stain Remover. If you are concerned about mold and mildew behind walls, underneath flooring, in ventilation systems or other unseen areas, contact a professional who specializes in mold and mildew remediation. For commercial buildings,' follow appropriate guidelines for mold removal. Refer to EPA's webpage for additional information on mold and mildew remediation.

ONE-COAT SYSTEM- No Priming Requiredl PERMA-GUARD will adhere to any sound surface. It bonds to new or previously painted drywall, wood, [Optional] and primed metal [Optional] and glossy surfaces without sanding. When applied according to label directions PERMA-GUARD seals the surface, providing moisture resistance and protection of the painted surface from mold, mildew and [Optional] stain and odor­causing bacteria. In most cases a spray application can be completed in one coat, but

'for extremely porous or irregular surfaces, a second coat may be required.' To properly restore surfaces, spot prime and fill all nail holes and gouges with Zinsser READY PATCH™ Spackling & Patching Compound. Seal all stains with an appropriate stain killing primer-sealer, such as B-I-N® Primer-Sealer or Bulls Eye® Odorless [Opt] Bulls Eye 1-2-3® [Opt] before painting.

: APPLICATION - Shake or stir well before using. Apply with synthetic bristle brush' roller, pad applicator or sprayer. For airless spraying, use a .017 tip and high medium (2000-2600 PSI) pressure. Apply when air and surface temperatures are betwe.A" ~o-90°F (10°-32°C) and humidity is less than 80%. May be applied over slightly ~~> ~0o.· surfaces. . v~,:;~,~ 'Q'& '~

.~u. 0 ~0"" (\~,s.:. o0: v ... r[? DRY TIME. - At normal temperatures: 70°F (21°C) PERMA-GUARD dn ours, ~ 6~~:C(}~ Full adheSion and hardness develop In 10 days. ~ ~ il)"~~<:;-~~~./~~~O'

·0".,,0 <;:?,~ .[Optional] TINTING - Maybe tinted to off-white, pastel or medium colors with o~0(J ?>~i~;;}~j(; universal colorants. Start with 75% of the tinting formula for a given color and ,ijf~(~ o0~ {,a necessary. Maximum tint - 4 oz. per gallon (20 oz. per 5 gallon pail). -\:):~6F~o00~O-\}'~\'). 'i

. ..<; .. #~~~ ... t§ /\ 0

April 8, 2009 Page 12 of ~

Page 17: NOTICE OF PESTICIDE: PERMA-GUARD MOLD AND ......2009/09/30  · 05590 and 03273 even when subject to combined stains of mold and mildew spores" and "PERM GUARD also, passes Bacterial

(

(

'J PERMA-GUAr~\ Volume 1 - Page 61 of 100 'lot II PERMA-GUARD® Mold & Mildew Proof Interior Coating j .

PROFESSIONAL RESTORATION OR REMEDIATION USERS

[Optional] TINTING - May be tinted with universal colorants if color is desired. Maximum tint - 4 oz. per gallon.

~ COVERAGE - Apply at a rate of 250-400 sq ft per gallon. Coverage will vary with the porosity of the surface and method of application.

CLEANUP - Clean application tools, spatters, and spills immediately with warm water and liquid detergent; rinse with water. Follow equipment manufacturer's directions to clean spray equipment. Remove dried product with a heavy-duty ammoniated household cleaner; rinse with water.

~ LIMITATIONS - Not intended for application to floors or any surface subject . to immersion or prolonged contact with water; including shower enclosures, saunas or

steam rooms. ~'Not recommended for use in HVAC ductwork.

LIMITED WARRANTY: PERMA-GUARD [Optional] Mold & Mildew-Proof Interior Coating is guaranteed for [Optional] five [Optional] ten years from the date of application to provide protection of the painted surface from mold & mildew when one coat is applied according to the label directions. Application of other paints over

, PERMA-GUARD nullifies the warranty. The contents are warranted to be free of defects for two years from date of manufacture. All warranties and guarantees are limited to replacement or refunded value of product actually used when supported by proof of purchase. This guarantee is not transferable. Directions are as complete as

, possible but cannot encompass all conditions, applications, techniques and/or surfaces which are beyond our control. If you have a question, check with your dealer or call 888-855-1774.

April 8, 2009 Page 13 of 13