1
Original format A2 1 6 7 2 3 1 2 3 4 5 6 7 8 A B C D E F A B C D E F 3650 1770 (1814) 700 LV COMPARTMENT WIDTH 950 HV COMPARTMENT WIDTH 731 SIDE DOOR WIDTH 498 687 396 161 451 1657 1213 271 105 105 105 105 796 273 9 15/10/15 ECN 1440: ISSUED FOR CONSTRUCTION MJ AS TAS 08 23-07-15 ABB REALY ADDED & UPDATED TO SUIT SH WH TAS 07 10-11-14 MASS PL. ADDED ON TX, N/PL. DESC. UPDATED. ECN # 1283. DS MJ TAS 06 27-08-14 TX-HV CABLE SPLINES ADDED & GPO CHANGED TO IEC TYPE. DS AS LC 05 03-06-14 KIOSK BRAND LABEL DELETED. DS LC TAS 04 01-11-13 1x 13 HOLE ADDED ON EARTH BAR LV END & 3x 26 HOLE ADDED ON EA. GL. PL. FOR CABLE SCREEN EARTHING. DS AS TAS 03 25-06-13 AS BUILT PK LC AS 02 14-06-13 BAT. CHARGER AND TERM. RELOCATED TO THE FRONT PK LC AS 01 14-05-13 RELEASED FOR MANUFACTURE PK AS TS 00 10-4-13 RELEASED FOR REVIEW PK LC TS REV DATE DETAILS OF REVISION DRAWN CHKD APPR QTY. ITEM DESCRIPTION PART NO. 1 1 LV BUSHING BAFFLE 7284436901 3 2 SURGE ARRESTOR AK POWER SOLUTIONS 5KA BSH5122 1 3 PLUG,BR,FLG,DN20,3/4,M PLG1840 1 4 CABLE SUPPORT RAIL SWG1717_1120 1 5 3 FUNCTION RANGE RM6 RM62N61XIDIEAB1 1 6 EARTH LEAD, 120mm2, 2700L 3681003-8 6 7 EARTH LEAD, 70mm sq., 370L 3681003-5 1 8 EARTH LEAD, 70mmsq, 900L 3681003-6 2 9 LV-SAIF-70-N800-1 3681004-33 1 10 OIL PRESENCE INDICATOR IND5026 1 11 CAP ALUM 130DIA HERM / SEAL CAPAL130 1 12 MASS PLATE KK 1500 kVA 4942191001 1 13 THERMAL INDI POCKET 3/4 BSP THM5213 16 14 CONNECTION FLEXI Cu 70 X 4 SEC F D D 6641784701 1 15 EARTH CONN. TO TX 66411340-02-01 1 16 WA- 2 WAY RM6 SUPPORT LINTEL BAU1719601 1 17 MAIN EARTH BAR 66411340-01-01 3 18 SIGN DANGER-HIGH VOLT KEEP OUT 4942122-9 1 19 OIL BUND WA 6675359701 1 20 HV CABLE CLAMP ASSY XLPE CABLE 7284413501 2 21 SWITCH DOOR P/BUTTON 250V .25A SWG1765 1 22 NAME PLATE KK 1500kVA, 11/0.433 Dyn1 4943089601 3 23 INSERT 22kV,200A, ELASTIMOLD K1501-A1 BSH1664 3 24 BUSH WELL 33kV, 200 A, TO SUIT ELAST. K1501-A1 BSH2023 1 25 TAP CHANGER TAP3696P 1 26 RM6 SWITCHGEAR EXTENSION HANDLE A048069 2 27 LIGHT 18 W FLURO WITH SLEEVE LHT2913-0 1 28 HV SWITCH STAND 3-WAY RM6 6675371 1 29 CT STEMAR 400/5 HV EFI CCT2280 3 30 CT STEMAR 2450-1837/2.89 EA LV CCT2277 3 31 CT STEMAR 100/5 HV DIFF PROT CCT2279 1 32 LV BOARD 2500A INTERPACT 7284575-05101 1 33 BUSHING PAD RESIN 3000 AMP 383 PAD2700-3 1 34 FINAL ENCLOSURE ASSY. (4-15) BAU1719001 1 35 HV PROTECTION BOX ASSY 7284442901 1 36 TANK FINISH KPX 6605140801 SUMMARY OF MASS:- TRANSFORMER UNTANKING 2350 kg OIL VOLUME 1450 Ltr TANK & FITTINGS 1540 kg TRANSFORMER TOTAL 5150 kg ENCLOSURE 330 kg BASE 285 kg L.V. SWITCHGEAR 240 kg H.V. SWITCHGEAR 275 kg Oil Bund 150 kg KIOSK TOTAL 6430 kg State: 9223383502 9 1/1 Document Number: Doc. Rev. Sheet: 3 WAY RM6 2500A LV BOARD OIL BUND AUSGRID KPX KIOSK 1500kVA 11/0.433V Dyn1 ISO 8015 0.027 ISO 2768 cl mm Scale: Technical Specification: Units of measure : BATTERY TEST ASSY BATTERY CHARGER HV EXTENSION HANDLE MOUNTED INSIDE OF HV LH DOOR GENERAL NOTES: 1 - ENCLOSURE DOORS (TOP) FITTED WITH SPRING LOADED TOWER BOLTS 2 - CHANNEL BASE FITTED WITH 32mm CONDUIT FROM END TO END 1 EACH SIDE USED FOR ALL CONTROL WIRING 3 - BATTERY BOX TO BE INSULATED FROM FRAME EARTH 4 - ENCLOSURE FINISH - POWDER COATED RAINFOREST GREEN G15 5 - REFER TO 6640361 FOR HV PROTECTION WIRING DIAGRAM. NOTE: CONTRACT No. : AG2869-11 ITEM No. 34 STOCK CODE : 178853 EARTH BAR M10 (3x) SCALE 0.025 ONE ON HV RH DOOR SIDE ACCESS DOOR TX ACCESS DOOR KIOSK ID TAG - MOUNTED INSIDE 4x LIFTING POINTS THREE POINT LATCHING RH SIDE OF HV & LV END PAD LOCKABLE 3 THK ALUM ENCLOSURE GENERATOR ACCESS COVER 18 34 18 LABEL HIGH VOLTAGE SCALE 0.050 BATTERY HOUSING 2x RELAY DIFFERENTIAL (EX AUSGRID) RELAY OVERCURRENT (ABB CO9) SHORTING LINKS HV PROTECTION BOX ASSY 3 10 13 14 21 22 23 24 27 30 BATTERY TEST BOX ASSY 25 12 20 LV END : LV BOARD: REF CONTRACT SPEC. 26 31 29 A 10A, FEMALE IEC Panel mount socket 1 11 16 33 4 SCALE 0.025 EARTH FAULT RELAY 5 15 17 19 28 32 35 36 2 4 INSIDE CABLE BOX. SCREEN EARTHING ARRANGEMENT CB FUNCTION TX-HV CABLE (0.050) A HV CABLE SCREEN EARTHING TX-HV CABLES The information is highly confidential and is the exclusive property of Schneider Electric copyright reserved. This drawing must not be used for any purpose other than that expressly permitted in writing by the owners and must not be disclosed or reproduced in any way without permission from the owners in writing. This drawing must be returned to the owners when the purpose has ceased. 7 08 08 6 6 1 REF

NOTE - Ausgrid

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Original format A21 6 72 3

1 2 3 4 5 6 7 8

A

B

C

D

E

F

A

B

C

D

E

F

3650

1770

(181

4)

700LV COMPARTMENT

WIDTH

950HV COMPARTMENT WIDTH

731SIDE DOOR WIDTH

498

687 396 161

451

1657

1213

271

105

105105105

796

273

9 15/10/15 ECN 1440: ISSUED FOR CONSTRUCTION MJ AS TAS08 23-07-15 ABB REALY ADDED & UPDATED TO SUIT SH WH TAS07 10-11-14 MASS PL. ADDED ON TX, N/PL. DESC. UPDATED. ECN # 1283. DS MJ TAS06 27-08-14 TX-HV CABLE SPLINES ADDED & GPO CHANGED TO IEC TYPE. DS AS LC05 03-06-14 KIOSK BRAND LABEL DELETED. DS LC TAS 04 01-11-13 1x 13 HOLE ADDED ON EARTH BAR LV END & 3x 26

HOLE ADDED ON EA. GL. PL. FOR CABLE SCREEN EARTHING.DS AS TAS

03 25-06-13 AS BUILT PK LC AS02 14-06-13 BAT. CHARGER AND TERM. RELOCATED TO THE FRONT PK LC AS01 14-05-13 RELEASED FOR MANUFACTURE PK AS TS00 10-4-13 RELEASED FOR REVIEW PK LC TS

REV DATE DETAILS OF REVISION DRAWN CHKD APPR

QTY. ITEM DESCRIPTION PART NO.1 1 LV BUSHING BAFFLE 72844369013 2 SURGE ARRESTOR AK POWER SOLUTIONS 5KA BSH51221 3 PLUG,BR,FLG,DN20,3/4,M PLG18401 4 CABLE SUPPORT RAIL SWG1717_11201 5 3 FUNCTION RANGE RM6 RM62N61XIDIEAB11 6 EARTH LEAD, 120mm2, 2700L 3681003-86 7 EARTH LEAD, 70mm sq., 370L 3681003-51 8 EARTH LEAD, 70mmsq, 900L 3681003-62 9 LV-SAIF-70-N800-1 3681004-331 10 OIL PRESENCE INDICATOR IND50261 11 CAP ALUM 130DIA HERM / SEAL CAPAL1301 12 MASS PLATE KK 1500 kVA 49421910011 13 THERMAL INDI POCKET 3/4 BSP THM5213

16 14 CONNECTION FLEXI Cu 70 X 4 SEC F D D 66417847011 15 EARTH CONN. TO TX 66411340-02-011 16 WA- 2 WAY RM6 SUPPORT LINTEL BAU17196011 17 MAIN EARTH BAR 66411340-01-013 18 SIGN DANGER-HIGH VOLT KEEP OUT 4942122-91 19 OIL BUND WA 66753597011 20 HV CABLE CLAMP ASSY XLPE CABLE 72844135012 21 SWITCH DOOR P/BUTTON 250V .25A SWG17651 22 NAME PLATE KK 1500kVA, 11/0.433 Dyn1 49430896013 23 INSERT 22kV,200A, ELASTIMOLD K1501-A1 BSH16643 24 BUSH WELL 33kV, 200 A, TO SUIT ELAST. K1501-A1 BSH20231 25 TAP CHANGER TAP3696P1 26 RM6 SWITCHGEAR EXTENSION HANDLE A0480692 27 LIGHT 18 W FLURO WITH SLEEVE LHT2913-01 28 HV SWITCH STAND 3-WAY RM6 66753711 29 CT STEMAR 400/5 HV EFI CCT22803 30 CT STEMAR 2450-1837/2.89 EA LV CCT22773 31 CT STEMAR 100/5 HV DIFF PROT CCT22791 32 LV BOARD 2500A INTERPACT 7284575-051011 33 BUSHING PAD RESIN 3000 AMP 383 PAD2700-31 34 FINAL ENCLOSURE ASSY. (4-15) BAU17190011 35 HV PROTECTION BOX ASSY 72844429011 36 TANK FINISH KPX 6605140801

SUMMARY OF MASS:-

TRANSFORMER

UNTANKING 2350 kg

OIL VOLUME 1450 Ltr

TANK & FITTINGS 1540 kg

TRANSFORMER TOTAL 5150 kg

ENCLOSURE 330 kg

BASE 285 kg

L.V. SWITCHGEAR 240 kg

H.V. SWITCHGEAR 275 kg

Oil Bund 150 kg

KIOSK TOTAL 6430 kg State:9223383502 9 1/1

Document Number: Doc. Rev. Sheet:

3 WAY RM6 2500A LV BOARD OIL BUND AUSGRID KPX KIOSK 1500kVA 11/0.433V Dyn1 ISO 8015

0.027 ISO 2768 cl mm Scale: Technical Specification: Units of measure :

BATTERY TEST ASSY

BATTERY CHARGER

HV EXTENSION HANDLEMOUNTED INSIDE OFHV LH DOOR

GENERAL NOTES:1 - ENCLOSURE DOORS (TOP) FITTED WITH SPRING LOADED TOWER BOLTS2 - CHANNEL BASE FITTED WITH 32mm CONDUIT FROM END TO END 1 EACH SIDE USED FOR ALL CONTROL WIRING3 - BATTERY BOX TO BE INSULATED FROM FRAME EARTH4 - ENCLOSURE FINISH - POWDER COATED RAINFOREST GREEN G155 - REFER TO 6640361 FOR HV PROTECTION WIRING DIAGRAM.

NOTE:CONTRACT No. : AG2869-11ITEM No. 34STOCK CODE : 178853

EARTH BARM10 (3x)

SCALE 0.025

ONE ON HV RH DOORSIDE ACCESS DOOR

TX ACCESS DOOR

KIOSK ID TAG - MOUNTED INSIDE

4x LIFTING POINTS

THREE POINT LATCHINGRH SIDE OF HV & LV ENDPAD LOCKABLE

3 THK ALUMENCLOSURE

GENERATOR ACCESS COVER

18

34 18

LABELHIGH VOLTAGE

SCALE 0.050

BATTERY HOUSING2x

RELAY DIFFERENTIAL(EX AUSGRID)

RELAY OVERCURRENT(ABB CO9)

SHORTING LINKS

HV PROTECTION BOX ASSY 3 10 13 14 21 22 23 24 27 30

BATTERY TEST BOX ASSY

25 12

20 LV END : LV BOARD: REF CONTRACT SPEC.

26

31 29

A

10A, FEMALE IEC Panel mount socket

1 11

16

33

4

SCALE 0.025

EARTH FAULT RELAY

5

15

17

19

28

32

35

36

2

4

INSIDE CABLE BOX.SCREEN EARTHING ARRANGEMENT

CB FUNCTION TX-HV CABLE(0.050)A

HV CABLE SCREENEARTHING

TX-HV CABLES

The information is highly confidential and is the exclusive property of Schneider Electric copyright reserved. This drawing must not be used for any purpose other than that expressly permitted in writing by the owners and must not be disclosed or reproduced in any way without permission from the owners in writing. This drawing must be returned to the owners when the purpose has ceased.

7

08

08

6

6

1

REF

t55164
Typewritten Text
242594_01r00