6
Basement 1st. Floor 3rd Floor 2nd Floor 1st Floor I-4 I-3 I-2 I-1 S-2 Low S-1 Moderate R-4 R-3 R-2 R-1 %g %g S S ALLOWABLE AREA City/County Private State APPENDIX B BUILDING CODE SUMMARY ALLOWABLE HEIGHT MECHANICAL SUMMARY SEE SHEET - ELECTRICAL SUMMARY SEE SHEET - ENERGY SUMMARY PLUMBING FIXTURE REQUIREMENTS ACCESSIBLE REGULAR TUBS FEMALE MALE FEMALE MALE DRINKING FOUNTAINS SHOWERS LAVATORIES URINALS WATERCLOSETS USE Wind Earthquake psf psf Pile Size, Type, and Capacity Presumptive Bearing Capacity Field Test Modal Equivalent Lateral Force Simplified Vy= Vx= Not Required Yes Architectural, Mechanical, Components anchored? Analysis Procedure Seismic Base Shear Dual w/ Special Moment Frame Dual w/ Intermediate R/C or Special Steel Iverted Pendulum Moment Frame Building Frame Bearing Wall Basic Structural System Site Classification Spectral Response Acceleration Occupancy Category (Table 1604.5) SOIL BEARING CAPACITIES: LATERAL DESIGN CONTROL: A B SEISMIC DESIGN CATEGORY Vy= Vx= mph (ASCE-7-02) Wind Base Shears (for MWFRS) Exposure Category Basic Wind Speed psf Wind Load: Snow Load: psf psf psf Floor Mezzanine Roof Live Loads: Seismic (Ie) Snow (Is) Wind (Iw) Importance Factors: DESIGN LOADS: STRUCTURAL DESIGN No Yes No Yes No Yes No Yes No Yes Panic Hardware Smoke Detection Systems Fire Alarm Exit Signs Emergency Lighting LIFE SAFETY SYSTEM REQUIREMENTS Tenant/Dwelling Unit Separation Occupancy/Fire Barrier Separation Corridor Separation Shaft Enclosures- Other Shaft Enclosures - Exit Supporting Beams & Joists Supporting Beams & Joists Roof Construction, including Floor Construction, including Reduction W/ * Provided Joints for Rated Design # Req'd Penetration for Rated Design # Assembly for Rated Design # Sheet # and Detail # Rating Walls & Partitions. Non-Load Bearing Exterior North East South West Interior Distance Separation Fire Interior West South East North Exterior Bearing Walls Girders & Trusses. including Columns, Structural Frame, FIRE PROTECTION REQUIREMENTS REFERENCE CODE PLANS SHOWN ON ALLOWABLE Building Height in Stories (Table 504.4) Building Height in Feet (Table 504.3) Allowable Area per story or Unlimited Increase Frontage Area for Area Table 506.2 Per Story Bldg Area and use Description Story No. TOTALS Separated Use (508.4) - See below for area calculations For each story, the area of the occupancy shall be such that the sum of the ratios of the actual floor area of each use divided by the allowable floor area for each use shall not exceed 1. Non-Separated Use (508.3) The required type of construction for the building shall be determined by applying the height and area limitations for each of the applicable occupancies to the entire building. The most restrictive type of construction, so determined, shall apply to the entire building. Parking Garage Repair Garage Enclosed Open Exception: Hr. Separation: Yes No Mixed Occupancy: Special Provisions (List code sections): Residential Utility and Miscellaneous Storage Mercantile Institutional H-1 High Hazard H-2 H-3 H-4 H-5 F-1 Factory-Industrial Educational Business A-5 A-4 A-3 A-2 Assembly A-1 Occupancy: Sub-Total New EXISTING Yes No Wet II No Yes Dry III I NFPA 13 NFPA 13R NFPA 13D Yes No III-B III-A II-A V-B I-B V-A IV I-A 1st Time Interior Completion Phone Email License Name Firm TOTALS 2nd Floor FLOOR Gross Building Area: Fire District: Standpipes: Sprinklers Construction Type: Basic Building Data New Building 2018 NC Building Code for: Other Retaining Walls >5' Structural Sprinkler-Standpipe Mechanical Plumbing Fire Alarm Electrical Civil Architectural Designer Lead Design Professional: Code Enforcement Jurisdiction: Owned By: Owner/Authorized Agent: Address: Name of Project: Email Addition 2018 NC Existing Building Code: High-piled Special Uses (List code sections): A Telephone Actual Area of Occupancy A Actual Area of Occupancy B Allowable Area of Occupancy A Allowable Area of Occupancy B 1 Open space area increases from Section 506.2 are computed thus: a. Perimeter which fronts a public way or open space having 20 feet minimum width = _______ (F) b. Total Building Perimeter = _________ (P) c. Ratio (F/P) = ___________ (F/P) d. W = Minimum width of public way = _________ (W) e. Percent of frontage increase If = 100 [ F/P - 0.25] x W/30 = ________ (%) 2 Unlimited area applicable under conditions of Sections 507. 3 Maximum Building Area = total number of stories in the building x D (max. 3 stories, 506.2). 5 Frontage increase is based on the unsprinklered area value in Table 506.2. Pin Number: Detonate Deflagrate Combust Health HPM I Condition 1 2 3 4 5 SPECIAL APPROVALS (feet) Party/Fire Wall Separation Smoke Barrier Separation Incidental Use Separation Special Approval: (Local Jurisdiction, Department of Insurance, OSC, DPI, DFS, ICC, etc., describe below) ENERGY REQUIREMENTS: The following data shall be considered minimum and any special attribute required to meet energy code shall also be provided. Each designer shall furnish the required portions of the project information for the plan data sheet. If energy cost budget method, state the annual energy cost budget vs allowable annual energy cost budget. THERMAL ENVELOPE Method of Compliance: Performance (ASHRA 90.1) Roof/ceiling Assembly (each assembly) Description of assembly U-Value of total assembly R-value of insulation Skylights in each assembly U-Value of skylight total square footage of skylights in each assembly Exterior Walls (each assembly) Description of assembly U-Value of total assembly R-value of insulation Openings (windows or doors with glazing) U-Value of assembly shading coefficient projection factor low e required if applicable Door R-Values Description of assembly U-Value of total assembly R-value of insulation Openings (windows or doors with glazing) U-Value of assembly low e required if applicable Door R-Values Walls adjacent to unconditioned space (each assembly) Walls below grade (each assembly) Description of assembly U-Value of total assembly R-value of insulation Description of assembly U-Value of total assembly R-value of insulation Floors over unconditioned space (each assembly) Floors slab on grade Description of assembly U-Value of total assembly R-value of insulation Horizontal/vertical requirement Slab heated I II III IV C D Renovation II-B Partial Class: Flood Hazard Area: No Yes Basement 3rd Floor Accessory Occupancies: Partial Historical Data Presumptive Field Test D C B E F SPECIAL INSPECTIONS REQUIRED: Yes No Existing New Required Existing Required New Climate Zone: 3A 4A 5A Prescriptive (ASHRA 90.1) Prescriptive (Energy Code) Performance (Energy Code) I-4 F-2 Moderate Low Incidental Uses (Table 509): Assumed and real property line locations Fire and/or smoke rated wall locations (Chapter 7) Life Safety Plan Sheet #: LIFE SAFETY PLAN REQUIREMENTS Exterior wall opening area with respect to distance to assumed property lines (705.8) Existing structures within 30' of the proposed building Occupancy types for each area as it relates to occupant load calculation (Table 1004.1.2) Occupant loads for each area Exit access travel distances (1017) Common path of travel distances (1006.2.1 & 1006.3.2(1)) Dead end lengths (1020.4) Clear exit widths for each corridor Maximum calculated occupant load each exit door can accommodate (1005.3) Actual occupant load for each exit door A separate schematic plan indicating fire rated floor/ceiling and/or roof structure Location of doors with panic hardware (1010.1.10) Location of doors with delayed egress locks and the amount of delay (1010.1.9.7) Location of doors with electromagnetic egress locks (1010.1.9.9) Location of doors equipped with hold-open devices Location of emergency escape windows (1030) The square footage of each fire area (202) The square footage of each smoke compartment Note any code exceptions ACCESSIBLE DWELLING UNITS (SECTION 1107) Total units Accessible Units Required Type A Units Provided Total Accessible Units Provided Accessible Units Provided Type B Units Required Type B Units Provided Type A Units Required ACCESSIBLE PARKING (SECTION 1106) Lot or Parking Area Total Accessible Spaces Provided Required Provided Total Total Parking Spaces Regular with 5' Access Aisle Accessible Spaces Provided Van Spaces with 132" Access Aisle 8' Access Aisle Shell / Core Phased Construction - Shell / Core Prescriptive Repair Chapter 14 Level I Level II Level III Existing: Alteration: Historic Property Change of Use Yes No Special Inspections: Constructed (date) : Renovated (date) : Occupancy Category (1604.5): I Current: II III IV I Proposed: II III IV Current Occupancy: Proposed Occupancy: 4 The maximum area of open parking garages must comply with Table 406.5.4. The maximum area of air traffic control towers must comply with Table 412.3.1. Columns Supporting Floors Floor Ceiling Assembly PERCENTAGE OF WALL OPENING CALCULATIONS (FEET FROM PROPERTY LINES) FIRE SEPARATION DISTANCE PROTECTION (TABLE 705.8) DEGREE OF OPENINGS (%) ALLOWABLE AREA (%) ACTUAL SHOWN ON PLANS UNISEX UNISEX Exempt Building: No Yes Existing building envelope complies with code: No Yes G001 APPENDIX B DRAWING INDEX Issued for: Job #: Date: 117 Cherry Street, Suite D Black Mountain, NC 28711 4 7 5 E N K A L A K E R O A D B U N C O M B E C O U N T Y S C H O O L S 20120 D R O P O F F E N T R Y W A Y A T E N K A H I G H S C H O O L F O R: C A N D L E R, N O R T H C A R O L I N A 52083 C O R P O R A T E A N I L O A R C H T R O N A SEAL I T O N A N D E R S ON AR C H I T E C T U R E A P R O F E S S I O N A L C O R P O R A T I O N . C . N , E L L I V E H S A G T C E T I H C R A N O R T H C R A O L I N A D E R E T S I G E R 10906 E O R G E A. A N D E R S O N III George Anderson III, AIA 828 989 5154 [email protected] CONSTRUCTION 16 AUG 2021 DRAWING INDEX DESCRIPTION NO. G001 APPENDIX B & LIFE SAFETY A100 SITE PLANS A101 PLANS A201 ELEVATIONS SECTIONS S001 STRUCTURAL NOTES S101 STRUCTURAL PLANS AND DETAILS Dropoff Entryway at Enka High School 475 Enka Lake Road, Candler NC 28715 Tripp Anderson, Architect 828-989-5154 [email protected] 9606-98-9000 Buncombe County 10906 George Anderson III Aiton Anderson Architecture 828) 989-5154 [email protected] 196 sf 196 sf Utility canopy 196 sf 5,500 sf 5,500 sf 5,500 sf 40' 1 15' 1 30'+ 30'+ 30'+ 30'+ 30'+ 30'+ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 N A N A N A N A N A N A N A N A N A N A N A N A 0 0 0 0 30'+ each side UP, NS no limit NOT APPLICABLE NO SPECIAL REVIEWS REQUIRED NOT APPLICABLE NOT APPLICABLE 37393 D. Paul Fama SKA Consulting Engineers 828) 274-4440 [email protected] 196 sf 5,500 sf 30'+ 0 0 30'+ 0 0 N A N A N A N A NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE NOT APPLICABLE PROJECT LOCATION NOT TO SCALE ENKA LAKE ENKA VILLAGE HOMINY VALLEY ELEMENTARY SCHOOL ENKA HIGH Smokey Park Hwy - 19 / 23 Enka Lake Road Pisgah Hwy - 151 Sand Hill Road to I-26 UNOCCUPIED UTILITY STRUCTURE 1.0 1.0 1.0 20 15 115 C 3k 3k 0.316 0.109 1k 1k 2,000

NOT APPLICABLE A.ANDEC.E,

  • Upload
    others

  • View
    16

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NOT APPLICABLE A.ANDEC.E,

Basement

1st. Floor

3rd Floor

2nd Floor

1st Floor

I-4I-3I-2I-1

S-2 LowS-1 Moderate

R-4R-3R-2R-1

%g%g SS

ALLOWABLE AREA

City/County Private State

APPENDIX B BUILDING CODE SUMMARY

ALLOWABLE HEIGHT

MECHANICAL SUMMARY SEE SHEET -

ELECTRICAL SUMMARY SEE SHEET -

ENERGY SUMMARY

PLUMBING FIXTURE REQUIREMENTS

ACCESSIBLEREGULARTUBSFEMALEMALEFEMALEMALE

DRINKING FOUNTAINSSHOWERSLAVATORIESURINALSWATERCLOSETS

USE

WindEarthquake

psf

psf

Pile Size, Type, and Capacity

Presumptive Bearing Capacity

Field Test

ModalEquivalent Lateral ForceSimplified

Vy=Vx=

Not RequiredYesArchitectural, Mechanical, Components anchored?

Analysis Procedure

Seismic Base Shear

Dual w/ Special Moment Frame

Dual w/ Intermediate R/C or Special Steel

Iverted PendulumMoment Frame

Building Frame

Bearing Wall

Basic Structural System

Site Classification

Spectral Response Acceleration

Occupancy Category (Table 1604.5)

SOIL BEARING CAPACITIES:

LATERAL DESIGN CONTROL:

A BSEISMIC DESIGN CATEGORY

Vy=Vx=

mph (ASCE-7-02)

Wind Base Shears (for MWFRS)

Exposure Category

Basic Wind Speed

psf

Wind Load:

Snow Load:

psf

psf

psf

Floor

Mezzanine

RoofLive Loads:

Seismic (Ie)

Snow (Is)

Wind (Iw)Importance Factors:

DESIGN LOADS:

STRUCTURAL DESIGN

No Yes

No Yes

No Yes

No Yes

No Yes

Panic Hardware

Smoke Detection Systems

Fire Alarm

Exit Signs

Emergency Lighting

LIFE SAFETY SYSTEM REQUIREMENTS

Tenant/Dwelling Unit Separation

Occupancy/Fire Barrier Separation

Corridor Separation

Shaft Enclosures- Other

Shaft Enclosures - Exit

Supporting Beams & Joists

Supporting Beams & Joists

Roof Construction, including

Floor Construction, including

Reduction

W/ *

Provided

Joints

for Rated

Design #

Req'd

Penetration

for Rated

Design #

Assembly

for Rated

Design #

Sheet #

and

Detail #

Rating

Walls & Partitions.

Non-Load Bearing

Exterior

North

East

South

West

Interior

Distance

Separation

Fire

Interior

West

South

East

North

Exterior

Bearing Walls

Girders & Trusses.

including Columns,

Structural Frame,

FIRE PROTECTION REQUIREMENTS

REFERENCE

CODE

PLANS

SHOWN ONALLOWABLE

Building Height in Stories (Table 504.4)

Building Height in Feet (Table 504.3)

Allowable

Area per story

or UnlimitedIncrease

Frontage

Area for

Area

Table 506.2

Per Story

Bldg Area

and use

DescriptionStory No.

TOTALS

Separated Use (508.4) - See below for area calculations

For each story, the area of the occupancy shall be such that the sum of the ratios of the actual

floor area of each use divided by the allowable floor area for each use shall not exceed 1.

Non-Separated Use (508.3)

The required type of construction for the building shall be determined by applying the

height and area limitations for each of the applicable occupancies to the entire building.

The most restrictive type of construction, so determined, shall apply to the entire building.

Parking Garage Repair GarageEnclosedOpen

Exception:Hr.Separation:YesNoMixed Occupancy:

Special Provisions (List code sections):

Residential

Utility and Miscellaneous

Storage

Mercantile

Institutional

H-1High Hazard H-2 H-3 H-4 H-5

F-1Factory-Industrial

Educational

Business

A-5A-4A-3A-2Assembly A-1

Occupancy:

Sub-TotalNewEXISTING

YesNo

WetIINo Yes DryIIII

NFPA 13 NFPA 13R NFPA 13DYesNo

III-B

III-AII-A

V-BI-B

V-AIVI-A

1st Time Interior Completion

Phone

EmailLicenseNameFirm

TOTALS

2nd Floor

FLOOR

Gross Building Area:

Fire District:

Standpipes:

Sprinklers

Construction Type:

Basic Building Data

New Building2018 NC Building Code for:

Other

Retaining Walls >5'

Structural

Sprinkler-Standpipe

Mechanical

Plumbing

Fire Alarm

Electrical

Civil

Architectural

Designer

Lead Design Professional:

Code Enforcement Jurisdiction:

Owned By:

Owner/Authorized Agent:

Address:

Name of Project:

Email

Addition

2018 NC Existing Building Code:

High-piled

Special Uses (List code sections):

A

Telephone

Actual Area of Occupancy A Actual Area of Occupancy B

Allowable Area of Occupancy A Allowable Area of Occupancy B

1 Open space area increases from Section 506.2 are computed thus:

a. Perimeter which fronts a public way or open space having 20 feet minimum width = _______ (F)

b. Total Building Perimeter = _________ (P)

c. Ratio (F/P) = ___________ (F/P)

d. W = Minimum width of public way = _________ (W)

e. Percent of frontage increase If = 100 [ F/P - 0.25] x W/30 = ________ (%)

2 Unlimited area applicable under conditions of Sections 507.

3 Maximum Building Area = total number of stories in the building x D (max. 3 stories, 506.2).

5 Frontage increase is based on the unsprinklered area value in Table 506.2.

Pin Number:

Detonate Deflagrate Combust Health HPM

I Condition 1 2 3 4 5

SPECIAL APPROVALS

(feet)

Party/Fire Wall Separation

Smoke Barrier Separation

Incidental Use Separation

Special Approval: (Local Jurisdiction, Department of Insurance, OSC, DPI, DFS, ICC, etc., describe below)

ENERGY REQUIREMENTS:

The following data shall be considered minimum and any special attribute required to meet energy code shall also be

provided. Each designer shall furnish the required portions of the project information for the plan data sheet. If energy

cost budget method, state the annual energy cost budget vs allowable annual energy cost budget.

THERMAL ENVELOPE

Method of Compliance:

Performance (ASHRA 90.1)

Roof/ceiling Assembly (each assembly)

Description of assembly

U-Value of total assembly

R-value of insulation

Skylights in each assembly

U-Value of skylight

total square footage of skylights in each assembly

Exterior Walls (each assembly)

Description of assembly

U-Value of total assembly

R-value of insulation

Openings (windows or doors with glazing)

U-Value of assembly

shading coefficient

projection factor

low e required if applicable

Door R-Values

Description of assembly

U-Value of total assembly

R-value of insulation

Openings (windows or doors with glazing)

U-Value of assembly

low e required if applicable

Door R-Values

Walls adjacent to unconditioned space (each assembly)

Walls below grade (each assembly)

Description of assembly

U-Value of total assembly

R-value of insulation

Description of assembly

U-Value of total assembly

R-value of insulation

Floors over unconditioned space (each assembly)

Floors slab on grade

Description of assembly

U-Value of total assembly

R-value of insulation

Horizontal/vertical requirement

Slab heated

I II III IV

C D

Renovation

II-B

Partial

Class:

Flood Hazard Area: No Yes

Basement

3rd Floor

Accessory Occupancies:

Partial

Historical DataPresumptiveField Test

DCB E F

SPECIAL INSPECTIONS REQUIRED: Yes No

Existing

New

Required

Existing

Required

New

Climate Zone:

3A 4A 5A

Prescriptive (ASHRA 90.1)Prescriptive (Energy Code)

Performance (Energy Code)

I-4

F-2

Moderate Low

Incidental Uses (Table 509):

Assumed and real property line locations

Fire and/or smoke rated wall locations (Chapter 7)

Life Safety Plan Sheet #:

LIFE SAFETY PLAN REQUIREMENTS

Exterior wall opening area with respect to distance to assumed property lines (705.8)

Existing structures within 30' of the proposed building

Occupancy types for each area as it relates to occupant load calculation (Table 1004.1.2)

Occupant loads for each area

Exit access travel distances (1017)

Common path of travel distances (1006.2.1 & 1006.3.2(1))

Dead end lengths (1020.4)

Clear exit widths for each corridor

Maximum calculated occupant load each exit door can accommodate (1005.3)

Actual occupant load for each exit door

A separate schematic plan indicating fire rated floor/ceiling and/or roof structure

Location of doors with panic hardware (1010.1.10)

Location of doors with delayed egress locks and the amount of delay (1010.1.9.7)

Location of doors with electromagnetic egress locks (1010.1.9.9)

Location of doors equipped with hold-open devices

Location of emergency escape windows (1030)

The square footage of each fire area (202)

The square footage of each smoke compartment

Note any code exceptions

ACCESSIBLE DWELLING UNITS

(SECTION 1107)

Total

units

Accessible

Units

Required

Type A

Units

Provided

Total

Accessible Units

Provided

Accessible

Units

Provided

Type B

Units

Required

Type B

Units

Provided

Type A

Units

Required

ACCESSIBLE PARKING

(SECTION 1106)

Lot or

Parking Area

Total

Accessible Spaces

Provided

Required Provided

Total

Total Parking Spaces

Regular with

5' Access

Aisle

Accessible Spaces Provided

Van Spaces with

132" Access

Aisle

8' Access

Aisle

Shell / Core Phased Construction - Shell / Core

Prescriptive Repair Chapter 14

Level I Level II Level III

Existing:

Alteration:

Historic Property Change of Use

YesNoSpecial Inspections:

Constructed (date) :

Renovated (date) :

Occupancy Category (1604.5): ICurrent: II III IV

IProposed: II III IV

Current Occupancy:

Proposed Occupancy:

4 The maximum area of open parking garages must comply with Table 406.5.4.

The maximum area of air traffic control towers must comply with Table 412.3.1.

Columns Supporting Floors

Floor Ceiling Assembly

PERCENTAGE OF WALL OPENING CALCULATIONS

(FEET FROM PROPERTY LINES)

FIRE SEPARATION DISTANCE

PROTECTION (TABLE 705.8)

DEGREE OF OPENINGS

(%)

ALLOWABLE AREA

(%)

ACTUAL SHOWN ON PLANS

UNISEXUNISEX

Exempt Building:

No Yes

Existing building envelope complies with code:

No Yes

G001

APPENDIX B

DRAWING INDEX

Issued for:

Job #:

Date:

117 Cherry Street, Suite D

Black Mountain, NC 28711

4

7

5

E

N

K

A

L

A

K

E

R

O

A

D

B U

N

C

O

M

B

E

C

O

U

N

T

Y

S

C

H

O

O

L S

20120

D R

O

P

O

F

F

E

N

T

R

Y

W

A

Y

A

T

E

N

K

A

H

I G

H

S

C

H

O

O

L

F

O

R

:

C A

N

D

L

E

R

, N

O

R

T

H

C

A

R

O

L

I N

A

52083

CORPORATE

ANILOARCHTRON

A SEALI TON

ANDER

SON ARCH ITECTURE

APROF E SS IONAL COR

PO

RATION

.C.N,ELLIVE

HSA

G

TCETI

HCRA

NO RTH C RA OLIN A

DERETSIGER

10906

EORG

E A. ANDERSONIII

George Anderson III, AIA

828 989 5154

[email protected]

CONSTRUCTION

16 AUG 2021

DRAWING INDEX

DESCRIPTIONNO.

G001 APPENDIX B & LIFE SAFETY

A100 SITE PLANS

A101 PLANS

A201 ELEVATIONS SECTIONS

S001 STRUCTURAL NOTES

S101 STRUCTURAL PLANS AND DETAILS

Dropoff Entryway at Enka High School

475 Enka Lake Road, Candler NC 28715

Tripp Anderson, Architect 828-989-5154 [email protected]

9606-98-9000Buncombe County

10906George Anderson IIIAiton Anderson Architecture 828) 989-5154 [email protected]

196 sf

196 sf

Utility canopy 196 sf 5,500 sf 5,500 sf

5,500 sf

40'

1

15'

1

30'+

30'+

30'+

30'+

30'+

30'+

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

0 0

N A N A

N A N A

N A N A

N A N A

N A N A

N A N A

0 0

0 0

30'+ each side

UP, NS no limit

N

O

T

A

P

P

L

IC

A

B

L

E

NO SPECIAL REVIEWS REQUIRED

N

O

T

A

P

P

L

IC

A

B

L

E

N

O

T

A

P

P

L

IC

A

B

L

E

37393D. Paul FamaSKA Consulting Engineers 828) 274-4440 [email protected]

196 sf 5,500 sf

30'+ 0 0

30'+ 0 0

N A N A

N A N A

N

O

T

A

P

P

L

IC

A

B

L

E

N

O

T

A

P

P

L

IC

A

B

L

E

N

O

T

A

P

P

L

IC

A

B

L

E

N

O

T

A

P

P

L

IC

A

B

L

E

PROJECT LOCATION

NOT TO SCALE

ENKA

LAKE

ENKA

VILLAGE

HOMINY VALLEY

ELEMENTARY SCHOOL

ENKA

HIGH

Smokey Park Hwy - 19 / 23

E

n

k

a

L

a

k

e

R

o

a

d

P

i

s

g

a

h

H

w

y

-

1

5

1

S

a

n

d

H

ill

R

o

a

d

t

o

I

-

2

6

UNOCCUPIED UTILITY STRUCTURE

1.0

1.0

1.0

20

15

115

C

3k 3k

0.316 0.109

1k 1k

2,000

AutoCAD SHX Text
1
AutoCAD SHX Text
S
AutoCAD SHX Text
+
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
+
Page 2: NOT APPLICABLE A.ANDEC.E,

Issued for:

Job #:

Date:

117 Cherry Street, Suite D

Black Mountain, NC 28711

CONSTRUCTION

16 AUG 2021

A100

4

7

5

E

N

K

A

L

A

K

E

R

O

A

D

B U

N

C

O

M

B

E

C

O

U

N

T

Y

S

C

H

O

O

L S

20120

D R

O

P

O

F

F

E

N

T

R

Y

W

A

Y

A

T

E

N

K

A

H

I G

H

S

C

H

O

O

L

F

O

R

:

C A

N

D

L

E

R

, N

O

R

T

H

C

A

R

O

L

I N

A

52083

CORPORATE

ANILOARCHTRON

A SEALITON

ANDER

SON ARCH IT ECTURE

APROF E SS IONAL COR

PORA

TION

.C.N,ELLIVE

HSA

G

TCETI

HCRA

NO RTH C RA OLI

N A

DERETSIGER

10906

EORG

E A. ANDERSONIII

George Anderson III, AIA

828 989 5154

[email protected]

SITE PLANS

GENERAL NOTES

A. SITE PLAN HAS BEEN CREATED USING FIELD

MEASUREMENTS ONLY AND WITHOUT THE

INFORMATION OF A DETAILED SITE SURVEY. IT

IS THE CONTRACTOR'S RESPONSIBILITY TO

FIELD VERIFY ALL EXISTING CONDITIONS,

LAYOUT, ELEVATIONS AND GRADES, AND

UTILITIES LOCATIONS PRIOR TO BEGINNING

WORK OR ORDERING ANY MATERIALS.

B. CAREFULLY REMOVE WAYFINDING SIGN AND

BENCHES, AND STORE FOR RE-INSTALLATION .

COORDINATE FINAL LOCATION OF BENCHES AND

SIGN WITH THE OWNER.

C. DEMOLISH SIDEWALKS IN THE AREA OF NEW

WORK, WITH CLEAN STRAIGHT SAWCUT JOINTS

AT PORTIONS OF WALKS TO REMAIN.

D. PROVIDE GRASS SEED AND STRAW AT ALL

AREAS OF DISTURBED SOIL.

1

16802468

SITE PLAN

EXISTING CONDITIONS

2

16802468

SITE PLAN

PROPOSED

EXISTING ADA PARKING AREA

EXISTING ASPHALT PAVED DRIVE

EX

IST

ING

CO

NC

RE

TE

SID

EW

ALK

E

X

IS

T

IN

G

C

O

N

C

R

E

T

E

S

ID

E

W

A

L

K

EX

IS

TIN

G C

ON

CR

ET

E S

ID

EW

ALK

STORM DRAIN

WAYFINDING SIGN

FIRE HYDRANT

BENCH

BENCH

10'-0"

6'-0"

NOTES & SPECIFICATIONS

1. NEW SIDEWALKS SHALL BE 4" THICK 4,000 PSI

CONCRETE ON 4" STONE BASE ON COMPACTED

SOIL, 6x6 #10 WWF, WITH 'PICTURE FRAME' EDGE,

LIGHT BROOM FINISH, PERPENDICULAR TO THE

DIRECTION OF PEDESTRIAN TRAVEL. 2%

MAXIMUM SLOPE IN ANY DIRECTION. PROVIDE

TURNDOWN EDGE, MIN. 12" BELOW GRADE, 8"

WIDE AT EDGE OF ASPHALT PAVING.

2. ALIGN CONTROL JOINTS AND EDGES OF NEW

SIDEWALKS WITH FACE OF BRICK PIERS. JOINTS

SHALL BE SPACED AT 10' O.C. MAXIMUM.

EXISTING ADA PARKING AREA

(NO WORK)

4 3 2 1 0 4 8

DETAIL PLAN

3

ADA CURB CUT

6'-0"

5'-0"

4'-0"

5'-0"

NOTE: 6" MAXIMUM ALLOWABLE

DIFFERENCE IN ELEVATION BETWEEN

SIDEWALK AND ASPHALT.

6'-0"

1:12 M

AX

. S

LO

PE

1:1

0 M

AX

.

1:1

0 M

AX

.

2'-0"

CAST IRON ADA DETECTABLE

WARNING SURFACE

20'-0"10'-0"

6'-0"

+/-

60' N

EW

SID

EW

ALK

NEATLY SAWCUT ASPHALT IN A

STRAIGHT LINE PARALLEL TO EXISTING

SIDEWALK FOR INSTALLATION OF NEW

WALK. REPAIR EDGE OF ASPHALT

FLUSH TO EXISTING ASPHALT AFTER

INSTALLATION OF NEW SIDEWALK.

EX

IST

ING

SLO

PE

(FIE

LD

VE

RIF

Y)

EXISTING SIDEWALK JOINT

PROPOSED CONCRETE C.J.

10'-0"

STORM DRAIN

FUTURE 8'x20' CANOPY (N.I.C.)

CONCRETE SPLASH BLOCK

PROPOSED CONCRETE C.J.

COMPRESSIBLE E.J. MATERIAL AT ALL

FOUR SIDES OF EACH BRICK PIER

2'-0"

FIRE HYDRANT

ALIGN EDGE WITH EXISTING

SIDEWALK JOINT

EXISTING SIDEWALK JOINT

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

CJ

EXISTING

SIDEWALK

ALIGN LAYOUT OF GRID PARALLEL TO EXISTING 10' SIDEWALK

FLO

W

Page 3: NOT APPLICABLE A.ANDEC.E,

1

B

A

2

1

B

A

2

1

B

A

2

Issued for:

Job #:

Date:

117 Cherry Street, Suite D

Black Mountain, NC 28711

CONSTRUCTION

16 AUG 2021

A101

4

7

5

E

N

K

A

L

A

K

E

R

O

A

D

B U

N

C

O

M

B

E

C

O

U

N

T

Y

S

C

H

O

O

L S

20120

D R

O

P

O

F

F

E

N

T

R

Y

W

A

Y

A

T

E

N

K

A

H

I G

H

S

C

H

O

O

L

F

O

R

:

C A

N

D

L

E

R

, N

O

R

T

H

C

A

R

O

L

I N

A

52083

CORPORATE

ANILOARCHTRON

A SEALITON

ANDER

SON ARCH IT ECTURE

APROF E SS IONAL COR

PORA

TION

.C.N,ELLIVE

HSA

G

TCETI

HCRA

NO RTH C RA OLI

N A

DERETSIGER

10906

EORG

E A. ANDERSONIII

George Anderson III, AIA

828 989 5154

[email protected]

PLANS

4 3 2 1 0 4 8

FLOOR PLAN

1

4 3 2 1 0 4 8

UPPER PLAN

2

4 3 2 1 0 4 8

ROOF PLAN

3

4 3 2 1 0 4 8

REFLECTED CEILING PLAN

4

210.51

DETAIL

5

12'-0"

12'-0"

210.51

DETAIL

6

210.51

DETAIL

7

A101

5&6

A101

7&8

12'-0"

12'-0"

1'-0" 1'-0"

1'-0"

1'-0"

11" 11"

11"

11"

10'-0"

1'-0"

1'-8"

1'-0" 1'-8"

1"

1"

12'-0"

12'-0"

3'-0" 3'-0"

3'-0"

3'-0"

10'-0"

210.51

DETAIL

8

1'-0"

1'-0"

1"

1"

1'-0" 1'-0"

NOTE: 0'-0" ELEVATION SHALL BE WHERE BRICK MEETS SIDEWALK AT COLUMN A1.

EXISTING GRADE IS SLIGHTLY SLOPED, SO EACH PIER WILL MEET GRADE AT A SLIGHTLY

DIFFERENT ELEVATION. ALL BRICK COURSING ON ALL PIERS SHALL ALIGN.

MODULAR BRICK

2

1

2

" STRUCTURAL STUDS @ 16" O.C.

MAX., FASTENED TO STRUCTURAL

STEEL FRAME @ 48" O.C. MAX.

5

8

" DENSGLAS GOLD

(OR EQUAL) GYPSUM

SHEATHING

HSS STEEL COLUMN

MODULAR BRICK

2

1

2

" STRUCTURAL STUDS @ 16" O.C.

MAX., FASTENED TO STRUCTURAL

STEEL FRAME @ 48" O.C. MAX.

5

8

" DENSGLAS GOLD

(OR EQUAL) GYPSUM

SHEATHING

HSS STEEL COLUMN

PAINTED STEEL PLATE

SEALANT JOINT

PAINTED CEMENTITIOUS

SOFFIT BOARD

5"x4" CONTINUOUS METAL GUTTER, ALL FOUR SIDES

4"x3" CONTINUOUS METAL DOWNSPOUT

METAL ROOFING SYSTEM SHALL BE 26 GAUGE SNAPLOCK TYPE ROOFING, 16" WIDE PANELS, WITH ALL METAL RIDGES AND

TRIM SUPPLIED BY THE ROOFING MANUFACTURER TO INSURE COLOR MATCH. PROVIDE SNOW GUARD SYSTEM

"COLORGUARD" BY S5! (OR EQUAL). BLUE METAL ROOF COLOR TO BE APPROVED BY THE ARCHITECT. INSTALL AND

FASTEN TO DECK ACCORDING TO MANUFACTURERS INSTRUCTIONS FOR CONCEALED FASTENER INSTALLATION, AND

WITH MANUFACTURER'S LAP TRIM DETAIL INTO GUTTERS. ROOF DECK SHALL BE 3/4" T&G PLYWOOD, ENTIRE DECK

COVERED WITH ICE & WATER SHIELD MEMBRANE. GUTTERS SHALL BE CONTINUOUS SEAMLESS LENGTHS, COLOR TO

MATCH ROOFING. DOWNSPOUT COLOR SHALL BE BEIGE TO MATCH BRICK. PROVIDE CONCRETE SPLASH BLOCK,

DIRECTING FLOW TOWARD EXISTINGSTORM DRAIN.

LOW PROFILE WEATHERPROOF PASSIVE ROOF

VENT WITH MINIMUM 50 SQ. IN. NET FREE AREA

NOTE: PRIOR TO ORDERING ROOF VENT,

VERIFY IT IS COMPATIBLE WITH METAL

ROOF SYSTEM, AND IT WILL FIT BETWEEN

ROOF PANEL RIBS. PAINT VENT BLUE

BEFORE INSTALLATION.

EXTERIOR CEILING SYSTEM SHALL BE "STOQUIK GOLD CEILING" FINISH SYSTEM BY STO

CORP. (OR EQUAL). 5/8" DENSGLAS GOLD (OR EQUAL) SUBSTRATE SUSPENDED WITH

ARMSTRONG DRYWALL GRID SYSTEM (OR EQUAL), CEILING FINISH SYSTEM CONSISTING OF

REINFORCING MESH, BASECOAT, PRIMER, AND FINISH COAT, SAND FINISH, BEIGE COLOR

TO MATCH BRICKS.

DIRECT APPLIED FINISH SYSTEM

FOR EXTERIOR CEILINGS

STORM DRAIN

4"x4" ELEC. BOX, CENTERED

ON PIER, 48" ABOVE GRADE,

WITH WEATHERPROOF COVER,

INSTALL FLUSH WITH FACE OF

BRICK (CONDUIT INSIDE PIER)

1" METALLIC CONDUIT TO

JB IN CEILING ABOVE

4"Ø SOFFIT VENTS W/

INSECT SCREEN

4"x4"x4" DEEP ELEC. BOXES

WITH WEATHERPROOF COVER,

INSTALL FLUSH WITH FINISH

FACE CEILING. CONNECT ALL

BOXES WITH 1" CONDUIT

ABOVE CEILING.

EQ

.E

Q.

EQ. EQ.

JB IN SOFFIT ABOVE

Page 4: NOT APPLICABLE A.ANDEC.E,

Issued for:

Job #:

Date:

117 Cherry Street, Suite D

Black Mountain, NC 28711

CONSTRUCTION

16 AUG 2021

A201

4

7

5

E

N

K

A

L

A

K

E

R

O

A

D

B U

N

C

O

M

B

E

C

O

U

N

T

Y

S

C

H

O

O

L S

20120

D R

O

P

O

F

F

E

N

T

R

Y

W

A

Y

A

T

E

N

K

A

H

I G

H

S

C

H

O

O

L

F

O

R

:

C A

N

D

L

E

R

, N

O

R

T

H

C

A

R

O

L

I N

A

52083

CORPORATE

ANILOARCHTRON

A SEALITON

ANDER

SON ARCH IT ECTURE

APROF E SS IONAL COR

PORA

TION

.C.N,ELLIVE

HSA

G

TCETI

HCRA

NO RTH C RA OLI

N A

DERETSIGER

10906

EORG

E A. ANDERSONIII

George Anderson III, AIA

828 989 5154

[email protected]

ELEVATIONS

SECTIONS

A201

3

4 3 2 1 0 4 8

ELEVATION

1

3'-4"

8"

12'-0"

2'-0"

26 GA. STANDING SEAM

METAL ROOF W/ 4 GUTTERS

AND 2 DOWNSPOUTS

ACCENT BRICK RECESSED

ROWLOCK OVER SOLDIER

COURSE (GRAY/BROWN)

FIELD BRICK, RUNNING

BOND, TYPICAL

(MATCH EXISTING SCHOOL)

FIELD BRICK RECESSED

PANEL FOR OWNER'S SIGN

ACCENT BRICK RECESSED

SOLDIER COURSE

(GRAY/BROWN)

1'-0"

2'-0"

1'-0"

11'-4"

STEEL BENT PLATE BRICK

LEDGER SUPPORTING BRICK

SOLDIER COURSE

CONCRETE FOUNDATIONS

BELOW FROSTLINE

4

12

1 0 1 2

SECTION

1 0 1 2

SECTION

ELASTOMERIC PLASTER

COATING ON CEMENT

BOARD CEILING

26 GA. STANDING SEAM

METAL ROOF WITH

SNO-GUARD CLIPS

5"x4" CONTINUOUS

METAL GUTTER

SIDEWALK AND GRADE VARY

0'-0" ELEVATION

15'-10

1

2

" T.O. STEEL

1"

ELASTOMERIC PLASTER

COATING ON CEMENT

BOARD SOFFIT

CEMENT BOARD FASCIA

VAPOR BARRIER OVER

PLYWOOD ROOF

SHEATHING

BRICK VENEER WITH

TIES AT 16" O.C.

EACH DIRECTION

5

8

" DENSGLAS GOLD

(OR EQUAL) GYPSUM

SHEATHING

2

1

2

" STRUCTURAL STUDS @ 16" O.C.

MAX., FASTENED TO STRUCTURAL

STEEL FRAME @ 48" O.C. MAX.

SOLDIER COURSE

ACCENT BRICK

10.25.5.751

DETAIL

BRICK VENEER

BRICK TIE

SELF-ADHERED

COUNTERFLASHING, SEALED

THRU-WALL FLASHING,

EXTEND BEYOND FACE OF

BRICK, TRIM FLUSH

GYPSUM SHEATHING ON

METAL STUD WALL FRAMING

HSS 7x7 COLUMN

8

1

2

"

STEEL PLATE BRICK

LEDGE, PAINTED

2'-10"

℄ ℄

2 3

4

2'-0"

A201

2

SAME ELEVATION FOR ALL 4 SIDES

CELL VENT WEEPS @ 24" O.C.

THRU FLASHING

AND WEEPS

THRU FLASHING

AND WEEPS

THRU FLASHING

AND WEEPS

1"

CONCRETE

SIDEWALK

ROOF FRAMING OR

PRE-ENGINEERED ROOF TRUSSES

EPDM OR ICE & WATER SHIELD BENEATH

BOTTOM OF WALL FRAME TRACKS

FIELD BRICK AND GROUT SHALL MATCH THE EXISTING BUILDING: MEDIUM PALOMINO

WIRECUT MODULAR BRICK BY MERIDIAN BRICK LLC IN COLUMBIA SC. ACCENT BRICK

SHALL BE BLACK METALLIC MODULAR BY MERIDIAN. CONTACT LOCAL PRODUCT REP

DEAN MOORE: [email protected].

ALL MASONRY MATERIALS SHALL CONFORM TO THE STANDARD ASTM C216 AND ASTM

C270, AND MASONRY WORK SHALL BE INSTALLED IN ACCORDANCE WITH ACI 530.1.

MORTAR SHALL BE REGULAR GRAY NON-COLORED MORTAR (TO MATCH EXISTING

BUILDING) WITH FIELD BRICK (PALOMINO), EXCEPT MORTAR AT ACCENT BRICK (BLACK)

SHALL BE DARK GRAY COLORED MORTAR (COLOR SELECTED FROM FULL RANGE OF

SUPPLIER'S SAMPLES BY ARCHITECT). ALL MORTAR SHALL BE TYPE 'N'.

A101

5

A101

6

1" 1"

A101

7

A101

8

Page 5: NOT APPLICABLE A.ANDEC.E,

Issued for:

Date:

117 Cherry Street

Black Mountain, NC 28711

16 AUGUST 2021

CONSTRUCTION

Project Number:

File Name: 210281-S0001

210281

Plotted: 8/18/2021 2:43 PM

CONSULTING

ENGINEERS

64 Peachtree Road Suite 30Asheville NC 28803-3153

t: 828 274 4440

AL License No. CA-3746-Ewww.skaeng.com

SKA Consulting Engineers, Inc.

S001

GENERAL

NOTES

21020Job #:

4 7

5

E N

K A

L

AK

E R

O A

D

B U

N C

O M

B E

C

O U

N T

Y

S C

H O

O L

S

D R

O P

O F

F E

N T

R Y

W A

Y A

T E

N K

A

H I

G H

S

C H

O O

L F

O R

:

C A

N D

L E

R,

N O

R T

H

C A

R O

L I

N A

STRUCTURAL DESIGN DATA

1. CODES AND STANDARDS:

A. 2018 N. C. REVISIONS TO THE 2015 INTERNATIONAL RESIDENTIAL CODE.

B. MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, ASCE 7-10.

C. BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, ACI 318-14.

D. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, AISC 360-10.

E. AF&PA - NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION.

2. OCCUPANCY CATEGORY - II

3. GEOTECHNICAL DESIGN DATA:

A. FOOTINGS - ALLOWABLE SOIL BEARING PRESSURE 2000 PSF

4. LIVE LOADS (UNLESS NOTED OTHERWISE)

A. MINIMUM ROOF LIVE LOAD 20 PSF

5. ROOF SNOW LOADS (MINIMUM):

(1) GROUND SNOW LOAD (PG) 15 PSF

(2) FLAT ROOF SNOW LOAD (PF) 16.8 PSF

(3) IMPORTANCE FACTOR 1.0

(4) Ce 1.0

(5) Ct. 1.0

6. DEAD LOADS - PER CONSTRUCTION SHOWN ON DWGS

7. ROOF TRUSS LOADS:

A. LIVE LOADS (UNLESS NOTED OTHERWISE)

(1) TOP CHORD MINIMUM 20 PSF

(2) BOTTOM CHORD 5 PSF

B. DEAD LOADS

(1) TOP CHORD 10 PSF

(2) BOTTOM CHORD - SUSPENDED 10 PSF

C. DEAD LOADS - MINIMUM VALUES FOR USE WITH UPLIFT

(1) TOP CHORD 6 PSF

(2) BOTTOM CHORD - SUSPENDED 6 PSF

8. WIND DESIGN DATA:

A. BASIC WIND SPEED 115 MPH

B. EXPOSURE CATEGORY B

C. INTERNAL PRESSURE COEFFICIENT 0.18/-0.18

9. EARTHQUAKE LOADS:

A. MAPPED SPECTRAL RESPONSE ACCELERATION:

SHORT PERIOD SS = 0.3161

1 SECOND PERIOD S1 = 0.1096

B. DESIGN SPECTRAL RESPONSE ACCELERATION:

SHORT PERIOD SDS = 0.326

1 SECOND PERIOD SD1 = 0.17

C. SITE CLASS D

D. RISK CATEGORY II

E. IMPORTANCE FACTOR 1.0

F. SEISMIC DESIGN CATEGORY C

G. SEISMIC FORCE RESISTING SYSTEM

STEEL NOT SPECIFICALLY DETAIL FOR SEISMIC

RESPONSE MODIFICATION COEFFICIENT (R) 3

SYSTEM OVERSTRENGTH FACTOR (ΩO) 3

DEFLECTION AMPLITUDE FACTOR (Cd) 3

SEISMIC RESPONSE COEFFICIENT (Cs) 0.0143

H. ANALYSIS PROCEDURE - EQUIVALENT LATERAL FORCE

I. DESIGN BASE SHEAR 1 KIP

FOUNDATIONS

1. ALL FOOTINGS ARE DESIGNED TO BEAR ON RESIDUAL SOIL OR COMPACTED ENGINEERED FILL

AND TO HAVE A MINIMUM BEARING CAPACITY AS LISTED UNDER "STRUCTURAL DESIGN DATA” IN

THE GENERAL NOTES. FOOTING EXCAVATIONS ARE TO BE INSPECTED BY AN INDEPENDENT

TESTING LABORATORY FOR SUITABLE SOILS, BEARING PRESSURE, AND COMPACTION.

COMPACTION OF SOIL UNDER FOOTINGS TO BE 95% OF THE MAXIMUM STANDARD PROCTOR DRY

DENSITY.

5. SEE FOUNDATION PLAN NOTES FOR FURTHER REQUIREMENTS.

CONCRETE

1. CONCRETE SHALL BE NORMAL WEIGHT CONCRETE UNLESS NOTED OTHERWISE. CONCRETE

SHALL HAVE THE FOLLOWING MINIMUM 28-DAY COMPRESSIVE STRENGTHS UNLESS NOTED

OTHERWISE IN THE PLANS OR SPECIFICATIONS.

FOOTINGS 3000 PSI

EXTERIOR SLABS ON GRADE 4000 PSI

2. CONCRETE PERMANENTLY EXPOSED TO WEATHER SHALL HAVE A MAXIMUM WATER/CEMENT

RATIO OF 0.45 AND SHALL CONTAIN APPROXIMATELY 6% ENTRAINED AIR.

3. CONCRETE SHALL BE BATCHED USING MATERIALS AND PROPORTIONS DESIGNATED IN THE

APPROVED DESIGN MIXES. THE GENERAL CONTRACTOR SHALL PROVIDE QUALITY CONTROL OF

THE CONCRETE MIX.

4. CONCRETE SLUMP SHALL BE 3 TO 5 INCHES.

5. THE ADDITION OF WATER TO INCREASE SLUMPS ABOVE THE LEVEL SPECIFIED OR TO RETEMPER

CONCRETE WHICH HAS EXPERIENCED SLUMP LOSS DUE TO EXCESSIVE MIXING OR HEAT

BUILD-UP IS NOT PERMITTED.

6. CONCRETE SHALL BE HANDLED, PLACED, AND CONSOLIDATED IN ACCORDANCE WITH THE

REQUIREMENTS OF THE SPECIFICATIONS.

7. SEE ACI 305 & ACI 306 FOR CURING AND HOT AND COLD WEATHER REQUIREMENTS FOR

CONCRETE.

8. PROVIDE PRE-MOLDED EXPANSION-JOINT FILLER AT EDGES OF SLABS ON GRADE AGAINST

VERTICAL SURFACES UNLESS NOTED OTHERWISE.

9. ANCHOR BOLTS FROM FOOTINGS SHALL BE ACCURATELY LOCATED AND SECURELY TIED IN PLACE

PRIOR TO PLACEMENT OF THE CONCRETE. PLACEMENT OF ANCHOR BOLTS IN FRESH CONCRETE

AFTER THE CONCRETE HAS BEEN PLACED WILL NOT BE PERMITTED.

10. THE CONTRACTOR SHALL USE INSTRUMENTS TO MAINTAIN A CONTINUOUS CHECK OF THE

ELEVATIONS OF THE TOP SURFACES OF SLABS DURING THE PLACEMENT AND FINISHING OF THE

CONCRETE. ADJUSTMENTS SHALL BE MADE TO MAINTAIN THE SURFACES WITHIN THE SPECIFIED

TOLERANCES.

11. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING AND INSTALLING ALL

ANCHOR BOLTS, CLIPS, INSERTS, SLEEVES AND OTHER REQUIRED ITEMS IN ACCORDANCE WITH

THE CONTRACT DOCUMENTS AND IN COOPERATION WITH OTHER TRADES PRIOR TO THE PLACING

OF CONCRETE.

12. CONCRETE FORMWORK SHALL NOT BE REMOVED UNTIL CONCRETE HAS REACHED SUFFICIENT

STRENGTH TO NOT BE DAMAGED BY FORMWORK REMOVAL.

REINFORCING STEEL

1. DETAILING, FABRICATION, STORAGE, AND INSTALLATION OF REINFORCING, UNLESS OTHERWISE

SHOWN ON THE PLANS, SHALL COMPLY WITH APPLICABLE REQUIREMENTS OF THE “BUILDING

CODE REQUIREMENTS FOR REINFORCED CONCRETE” (ACI 318) AND THE “MANUAL OF STANDARD

PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES” (ACI 315), BOTH BY THE

AMERICAN CONCRETE INSTITUTE.

2. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60. REINFORCING STEEL WELDED

TO EMBEDDED STEEL PLATES OR SHAPES SHALL CONFORM TO ASTM A706. DO NOT WELD

REINFORCING BARS TO EACH OTHER.

3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A1064.

4. UNLESS NOTED OTHERWISE ON PLANS OR IN DETAILS, REINFORCING BARS MARKED ON THE

PLANS AS BEING CONTINUOUS SHALL BE LAPPED AT SPLICE LOCATIONS AS SHOWN IN SCHEDULE.

FOR SPLICES AT CORNERS OR INTERSECTIONS OF WALLS AND BEAMS, SEE TYPICAL DETAILS.

5. REINFORCING STEEL SHALL BE CLEAN OF MUD, DEBRIS, LOOSE RUST, CEMENT GROUT, OR ANY

OTHER MATERIAL WHICH MAY INHIBIT BOND BETWEEN THE STEEL AND THE CONCRETE.

6. REINFORCING SHALL BE SECURELY TIED AND ANCHORED IN PLACE BEFORE CONCRETE

PLACEMENT, TO PREVENT DISLOCATION.

7. UNLESS OTHERWISE NOTED, CONCRETE COVERAGE ON REINFORCING STEEL SHALL BE AS

FOLLOWS:

FOOTINGS - BOTTOM 3"

FOOTINGS - ALL OTHER FACES 2"

SLAB-ON-GRADE - TOP 1"

SLAB-ON-GRADE - BOTTOM 2"

8. BARS SHALL BE BENT ONLY USING APPROVED METHODS. BARS SHALL NOT BE BENT AFTER

PARTIAL EMBEDMENT IN HARDENED CONCRETE.

STRUCTURAL STEEL

1. ROLLED STEEL W-SHAPES SHALL CONFORM TO ASTM A992, GRADE 50, FY=50

KSI. COLD FORMED STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE-B,

FY=46 KSI. ALL OTHER ROLLED STEEL SHAPES, PLATES, AND BARS, SHALL

CONFORM TO ASTM A36, FY=36 KSI. ANCHOR BOLTS SHALL CONFORM TO ASTM

F1554, GRADE 36 AND SHALL BE HOT DIPPED GALVANIZED..

2. FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL BE IN

ACCORDANCE WITH AISC SPECIFICATIONS, COMMENTARY, AND CODE OF

STANDARD OF PRACTICE.

3. WELDS:

A. ALL WELDS SHALL BE MADE IN ACCORDANCE WITH AWS D1.1 STRUCTURAL

WELDING CODE - STEEL BY THE AMERICAN WELDING SOCIETY FOR THE

MATERIAL BEING WELDED. WELDS SHALL BE MADE USING E70XX

LOW-HYDROGEN ELECTRODES UNLESS OTHERWISE NOTED.

B. GALVANIZED STEEL SHALL BE WELDED IN ACCORDANCE WITH AWS D19 -

WELDING ZINC COATED STEEL BY THE AMERICAN WELDING SOCIETY.

STEEL SURFACES SHALL BE FREE OF ZINC IN THE AREA TO BE WELDED.

C. WELDS SHALL BE MADE BY WELDERS WHO HAVE BEEN QUALIFIED BY TESTS

AS PRESCRIBED IN AWS D1.1 BY THE AMERICAN WELDING SOCIETY, TO

PERFORM THE TYPE OF WORK REQUIRED.

D. ALL SHOP WELDS SHALL BE A MINIMUM 3/16" AND ALL FIELD WELDS SHALL

BE A MINIMUM 1/4", UNLESS NOTED OTHERWISE. INDICATED WELDING OF

CONNECTED PARTS SHALL BE "CONTINUOUS" OR "ALL AROUND" AS

APPLICABLE, UNLESS NOTED OTHERWISE.

E. WELDS SHALL BE CLEANED AND TOUCHED UP WITH THE APPROPRIATE

PAINT OR ZINC COATING.

F. PROVIDE SEAL WELDS ON ALL WELDED STEEL JOINTS EXPOSED TO VIEW,

MOISTURE, OR CORROSIVE CONDITIONS WHICH WOULD NOT OTHERWISE BE

WELDED FOR STRENGTH.

FRAMING LUMBER & SHEATHING

1. ROOF SHEATHING SHALL BE 5/8” APA RATED SHEATHING WITH A 48/24 SPAN

RATING, EXPOSURE 1. SECURE TO SUPPORTING WOOD FRAMING WITH 10d NAILS @ 6” O/C @ PANEL

EDGES AND 10d NAILS, @ 12” O/C AT PANEL INTERIOR SUPPORTS. ALLOW 1/8” SPACE BETWEEN PANEL

ENDS AND EDGES, TYP.

2. ALL LUMBER SHALL BE PROTECTED FROM MOISTURE, HEAT AND DAMAGE DURING DELIVERY, STORAGE

AND ERECTION.

3. ALL LUMBER SHALL BE SOUTHER YELLOW PINE #2 OR BETTER.

4. METAL CONNECTORS USED TO CONNECT WOOD FRAMING MEMBERS SHALL BE EQUIVALENT TO

CONNECTORS SPECIFIED ON THE DRAWINGS. METAL CONNECTORS USED WITH PRESSURE TREATED

LUMBER SHALL HAVE A LONG-TERM CORROSION PROTECTIVE FINISH.

WOOD TRUSSES (ALTERNATE)

1. ROOF TRUSSES SHALL BE DESIGNED BY THE TRUSS MANUFACTURER IN ACCORDANCE WITH THE

GEOMETRY, SUPPORT LOCATION, AND LOAD INFORMATION SHOWN ON THE DRAWINGS. MEMBER

DESIGNS SHALL BE IN ACCORDANCE WITH THE "NATIONAL DESIGN SPECIFICATION FOR WOOD

CONSTRUCTION" BY THE NATIONAL FOREST PRODUCTS ASSOCIATION, AND CONNECTION

DESIGNS SHALL BE IN ACCORDANCE WITH THE "TRUSS PLATE INSTITUTE DESIGN

SPECIFICATIONS". WOOD TRUSS SHOP DRAWINGS SHALL SHOW COMPLETE CONSTRUCTION

INFORMATION AND SHALL BEAR THE SEAL OF A QUALIFIED PROFESSIONAL ENGINEER THAT IS

REGISTERED IN THE STATE WHERE THE BUILDING IS LOCATED AND IS KNOWLEDGEABLE IN THE

DESIGN AND FABRICATION OF WOOD TRUSSES.

2. WOOD TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH THE GRAVITY AND WIND LOADING

INFORMATION CONTAINED IN THESE DRAWINGS, AND IN ACCORDANCE WITH ALL APPLICABLE

PROVISIONS OF THE "NORTH CAROLINA STATE BUILDING CODE".

3. TOP AND BOTTOM CHORD MEMBERS SHALL BE FABRICATED FROM KILN-DRIED YELLOW PINE, NO.

2 GRADE OR BETTER. WEB MEMBERS SHALL BE FABRICATED FROM KILN-DRIED YELLOW PINE, NO.

2 GRADE OR BETTER.

4. PROVIDE TEMPORARY AND PERMANENT TRUSS BRACING IN ACCORDANCE WITH THE

RECOMMENDATIONS OF THE TRUSS PLATE INSTITUTE STANDARD BWT-76 "BRACING WOOD

TRUSSES", AND IN ACCORDANCE WITH THE MANUFACTURER'S PRINTED INSTRUCTIONS.

DRAWINGS & COORDINATION

1. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL, MECHANICAL,

ELECTRICAL, AND PLUMBING DRAWINGS, AND DRAWINGS OF OTHER TRADES. THE CONTRACTOR

SHALL BE RESPONSIBLE FOR SEEING THAT THE WORK OF ALL TRADES IS COORDINATED WITH

THE STRUCTURAL WORK.

2. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL DIMENSIONS SHOWN ON THE CONTRACT

DOCUMENTS.

3. ANYTHING WHICH, IN THE OPINION OF THE CONTRACTOR, APPEAR TO BE DEFICIENCIES,

OMISSIONS, CONTRADICTIONS OR AMBIGUITIES IN THE PLANS SHALL BE BROUGHT TO THE

ATTENTION OF THE DESIGNER. CORRECTIONS OR WRITTEN INTERPRETATIONS SHALL BE ISSUED

BEFORE CONSTRUCTION OF THE AFFECTED WORK MAY PROCEED.

4. DETAILS ARE MARKED AT THE SPECIFIC LOCATION WHERE THEY APPLY, BUT ALSO INDICATE

GENERAL CONSTRUCTION REQUIREMENTS FOR OTHER LOCATIONS WITH SIMILAR CONDITIONS.

5. DETAILS NOTED AS "TYPICAL" MAY NOT BE REFERENCED ON THE DRAWINGS. TYPICAL DETAILS

APPLY AT ALL LOCATIONS WHERE THE TYPE OF CONSTRUCTION SHOWN IN THE TYPICAL DETAIL

OCCURS.

CONSTRUCTION

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION AND

ERECTION OF STRUCTURAL MATERIALS IN ACCORDANCE WITH THE DRAWINGS.

2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO ORDERING MATERIALS OR

PROCEEDING WITH NEW WORK IN AREAS AFFECTED BY EXISTING CONDITIONS. THE DESIGNER

SHALL BE INFORMED IN WRITING OF CONFLICTS BETWEEN EXISTING AND PROPOSED NEW

CONSTRUCTION.

3. THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION, AND ANY

TEMPORARY BRACING OR SUPPORT REQUIRED TO ACCOMMODATE THE CONTRACTOR'S MEANS

AND METHODS ARE THE RESPONSIBILITY OF THE CONTRACTOR.

4. THE CONTRACTOR IS RESPONSIBLE FOR LIMITING THE AMOUNT OF CONSTRUCTION LOAD

IMPOSED ON NEW AND/OR EXISTING STRUCTURES. SUCH LOADS SHALL NOT EXCEED THE

CAPACITY OF THE STRUCTURE AT ANY TIME.

5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DESIGNING, FURNISHING, ERECTING, AND

REMOVING ANY SHORING AND BRACING REQUIRED DURING CONSTRUCTION, INCLUDING BRACING

REQUIRED FOR SIDES OF EXCAVATIONS DURING FOUNDATION CONSTRUCTION AND TEMPORARY

BRACING FOR WALLS.

6. THE CONTRACTOR SHALL INFORM THE DESIGNER, IN WRITING, OF ANY DEVIATION FROM THE

CONTRACT DOCUMENTS. CONTRACTOR SHALL NOT BE RELIEVED OF THE RESPONSIBILITY FOR

SUCH DEVIATION BY VIRTUE OF THE DESIGNER'S REVIEW OF SHOP DRAWINGS, PRODUCT DATA,

ETC. UNLESS THE CONTRACTOR HAS SPECIFICALLY INFORMED THE DESIGNER OF SUCH

DEVIATION AT TIME OF SUBMISSION, AND THE DESIGNER HAS GIVEN WRITTEN APPROVAL FOR

THE SPECIFIC DEVIATION.

7. NO OPENINGS NOR ANY CHANGES IN SIZE, DIMENSION OR LOCATION SHALL BE MADE IN ANY

STRUCTURAL ELEMENTS WITHOUT WRITTEN APPROVAL OF THE DESIGNER.

8. WHERE CONSTRUCTION TOLERANCES ALLOW FOR VARIATIONS IN LOCATION, SIZE, ETC. OF

STRUCTURAL ELEMENTS, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE

ALL MATERIALS AND LABOR NECESSARY TO MODIFY CONNECTION ELEMENTS AS REQUIRED TO

PROVIDE A FINISHED PRODUCT WHICH IS IN ACCORDANCE WITH THE REQUIREMENTS OF THE

DRAWINGS. ANY SUCH MODIFICATIONS REQUIRED SHALL BE REVIEWED AND APPROVED BY THE

DESIGNER PRIOR TO EXECUTION.

9. THE DESIGNER SHALL BE NOTIFIED AT THE PROPER TIME WHEN ITEMS ARE READY FOR FIELD

REVIEW. SUFFICIENT NOTICE SHALL BE GIVEN TO ALLOW SCHEDULING OF THE FIELD REVIEW.

SUBMITTAL NOTES

1. ALL SHOP DRAWINGS MUST BE REVIEWED AND STAMPED BY THE GENERAL CONTRACTOR PRIOR TO

SUBMITTAL. SUBMITTAL WITHOUT CONTRACTOR REVIEW WILL RESULT IN DELAYS. THE CONTRACTOR

SHALL CONFIRM THAT SHOP DRAWINGS HAVE BEEN COMPLETED AND CHECKED BY THE SUPPLIER PRIOR

TO SUBMISSION.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS IN ELECTRONIC FORMAT.

3. SHOP DRAWINGS SUBMITTALS REQUIREMENTS SHALL BE IN ACCORDANCE WITH THE STRUCTURAL

SPECIFICATIONS. CHANGES OR ADDITIONS MADE ON RESUBMITTED SHOP DRAWINGS SHALL BE CLEARLY

INDICATED, AND THE PURPOSE OF THE RESUBMITTAL SHALL BE NOTED ON THE TRANSMITTAL. REVIEW OF

THE RESUBMITTED SHOP DRAWINGS SHALL BE LIMITED SPECIFICALLY TO THE ITEMS NOTED FOR

CORRECTION ON THE PREVIOUS SUBMITTAL.

4. THE GENERAL CONTRACTOR SHALL SUBMIT THE FOLLOW SHOP DRAWINGS FOR STRUCTURE ENGINEER

AND ARCHITECT REVIEW:

A. CONCRETE MIX DESIGN

B. REINFORCING STEEL

C. STRUCTURAL STEEL (a)

D. STEEL STAIRS/LADDERS (a)(c)

E. PRE-FABRICATED WOOD ROOF TRUSSES (a)(c) (ALTERNATE)

5. MANUFACTURER'S LITERATURE: SUBMIT TWO COPIES OF MANUFACTURER'S LITERATURE FOR ALL

MATERIALS AND PRODUCTS USED IN CONSTRUCTION OF PROJECT.

6. THE ENGINEERS'S REVIEW OF SHOP DRAWINGS IS FOR GENERAL CONFORMANCE OF THE DESIGN

CONCEPT. CONTRACTOR SHALL SUBMIT A SCHEDULE OF SHOP DRAWINGS SUBMITTALS THAT IS

ACCEPTABLE TO BOTH CONTRACTOR AND ENGINEER. AFTER THE CONTRACTOR HAS REVIEW THE SHOP

DRAWINGS, PROMPT REVIEW BY THE ENGINEER WILL BE MADE OF ALL SUBMITTALS. FOR LARGE

SUBMITTALS, REASONABLE REVIEW TIME SHALL BE ALLOW AND MAY EXCEED TWO WEEKS. THE

CONCURRENT SUBMITTAL OF MULTIPLE SHOP DRAWINGS (“DUMPING”) WILL FURTHER EXTEND THE REVIEW

PROCESS AND TIME FRAME NECESSARY TO PROPERLY REVIEW EACH SUBMITTAL.

7. THE CONTRACTOR IS RESPONSIBLE FOR PROPER CHECKING AND COORDINATION OF DETAILS,

DIMENSIONS, SIZES AND QUANTITIES AS REQUIRED TO FACILITATE COMPLETE AND ACCURATE

FABRICATION AND ERECTION.

8. REPRODUCTION OF THESE CONTRACT DOCUMENTS FOR USE IN SHOP DRAWINGS IS NOT PERMITTED.

9. THE NOTATIONS FOLLOWING SUBMITTAL ITEMS INDICATE THE FOLLOWING:

A. INCLUDE A CERTIFICATE OF COMPLIANCE WITH CONTRACT DOCUMENTS SIGNED AND SEALED BY

THE PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA RESPONSIBLE FOR

THE DESIGN.

B. SUBMIT ONE COPY FOR INFORMATION AND RECORD ONLY.

10. CALCULATIONS AND SHOP DRAWINGS SHALL BE SIGNED AND SEALED BY A PROFESSIONAL ENGINEER

THAT IS REGISTERED IN THE STATE WHERE THE BUILDING IS LOCATED.

ELEV.

NEW COLUMN GRID

DESIGNATION

SHEET WHERE

SECTION IS DRAWN

SECTION NUMBER

ELEVATION NUMBER

SHEET WHERE

ELEVATION IS DRAWN

INDICATES

DIRECTION OF VIEW

INDICATES

DIRECTION OF VIEW

INDICATES AREA

SHOWN IN DETAIL

SHEET WHERE DETAIL

IS DRAWN

DETAIL NUMBER

Dwg.#

DRAWING SYMBOL LEGEND

ANNOT-LEGEND-SYMB.dwg

EXIST. COLUMN

GRID DESIGNATION

Page 6: NOT APPLICABLE A.ANDEC.E,

Issued for:

Date:

117 Cherry Street

Black Mountain, NC 28711

16 AUGUST 2021

CONSTRUCTION

Project Number:

File Name: 210281-S0101

000000

Plotted: 8/18/2021 2:46 PM

CONSULTING

ENGINEERS

64 Peachtree Road Suite 30Asheville NC 28803-3153

t: 828 274 4440

AL License No. CA-3746-Ewww.skaeng.com

SKA Consulting Engineers, Inc.

S101

----

21020Job #:

4 7

5

E N

K A

L

AK

E R

O A

D

B U

N C

O M

B E

C

O U

N T

Y

S C

H O

O L

S

D R

O P

O F

F E

N T

R Y

W A

Y A

T E

N K

A

H I

G H

S

C H

O O

L F

O R

:

C A

N D

L E

R,

N O

R T

H

C A

R O

L I

N A

Dwg.#

FOUNDATION PLAN1/4" = 1'-0"

000000-S2001.DWG

1 2

A

B

12'-0"

TY

P.

TY

P.

X'-X"COORDINATE SLAB

EDGE WITH ARCH.

DWGS.,TYP.

SAW CUT SLAB

CONTROLJOINTS

# 4 x 4'-0"RE-ENTRANTBARS

Dwg.#

ROOF FRAMING PLAN1/4" = 1'-0"

000000-S2002.DWG

1 2

A

B

12'-0"

BOTTOM PLATE BRICK

SUPPORT - SEE DETAIL

2 x 8 RAFTERS @ 24"O.C., TYP.

TY

P.

TYP.6

S101

2 x 8 CEILING JOISTS, EARAFTER.

W8x15 (+15'-10 1/2")

HSS-7X7X3/8 (+11'-11 3/8")

HSS-7X7X3/8 (+11'-11 3/8")

W8x15 (+15'-10 1/2")

2 x 8 COLLAR TIES, EA. SIDE

OF HIP BELOW RIDGE, EA

DIRECTION

X

2'-0" x 2'-0" AT CORNERS

2" CLR.

Dwg.#

TYPICAL SLAB EDGE AT COLUMN3/4" = 1'-0"

000000-6001.DWGS101

2

#3 TIES - 3 EA,

EQUALLY SPACED

(4) #6 DWLS - DRILL AND

EPOXY INTO CONCRETE

TYPICAL CORNER

PLAN VIEW

COLUMN AND BASEPLATE

ITEMS - SEE DETAIL 3/S101

VENEER - SEE

ARCH. DWGS.

(5) #5 EA. WAY

3" TO A.B.'S

4'-0" x 4'-0"

14" EXP. MATERIAL

XX

2 - #4, CONT.

SLAB REINF - SEE

PLAN NOTES

Dwg.#

TYPICAL SLAB EDGE DETAIL3/4" = 1'-0"

000000-S6002.DWGS101

1

EXTERIOR SLAB ON

GRADE BY OTHERS

BOND BREAKER

Dwg.#

TYPICAL COLUMN BASE DETAIL3/4" = 1'-0"

STD8022.DWGS101

3

COLUMN - SEE PLAN

TOP OF FOOTING

BASE PLATE - 3/4" x14" x 14"

4 - 3 4"Ø HEADED ANCHOR BOLTSw/ 2 NUTS EACH

C.L. - COLUMN, BASE PLATE &

FOOTING, EACH WAY

FOUNDATION PLAN NOTES

1. ELEVATIONS:

A. THE REFERENCE ELEVATION (0'-0") FOR ALL ELEVATIONS SHOWN ON THE FOUNDATION PLANS

SHALL BE AT THE TOP OF CONCRETE AT THE ENTRANCE STRUCTURE. SEE SITE PLAN FOR

SPECIFIED ELEVATION OF TOP OF CONCRETE.

3. ALL FOOTING REINFORCING SHALL BE SUPPORTED ON CHAIRS OR PRECAST CONCRETE BLOCKS ON

THE SOIL AND SHALL BE SECURED AGAINST LATERAL MOVEMENT.

4. IF RAINFALL OR GROUNDWATER INTRUSION IS IMMINENT BEFORE PLACEMENT OF CONCRETE IN

FOOTING EXCAVATIONS, A 2" THICK "MUD MAT" OF LEAN CONCRETE SHALL BE PLACED IN THE

EXCAVATION AFTER OVER EXCAVATING 2" IN DEPTH. FOR LIGHT PRECIPITATION CONDITIONS,

PROTECT BOTTOM AND SIDES OF EXCAVATION WITH TEMPORARY 6 MIL POLYETHYLENE LINING. ANY

SOIL WHICH IS SOFTENED DUE TO MOISTURE EXPOSURE SHALL BE UNDERCUT TO FIRM SOIL AND

THE DEPTH OF THE FOOTING SHALL BE INCREASED TO REPLACE THE SOFT SOIL THAT WAS

REMOVED.

5. UNLESS OTHERWISE NOTED, THE CONCRETE SLAB-ON-GRADE SHALL COMPLY WITH THE

FOLLOWING:

THICKNESS: 4"

REINFORCING: 6 x 6 - W2.9 x W2.9 W.W.F. IN MATS, NOT ROLLS, PLACED 1" CLEAR FROM

TOP SURFACE

VAPOR BARRIER: SEE ARCHITECTURAL DRAWINGS

STONE BASE: MINIMUM 4" COMPACTED WASHED STONE

6. SLAB SLOPES: SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF FLOOR DRAINS, WALL SLEEVES,

RADON VENTS, PVS BOOTS FOR DOWNSPOUTS AND SLOPED SLAB AREAS. SLOPE SURFACE

UNIFORMLY TO DRAIN. SLOPED SLABS WHICH POND WATER SHALL BE REPLACED.

BEAM - SEE PLAN

SEE PLAN FOR

STEEL COLUMN.

TYPICAL DETAILMOMENT CONNECTION AT COLUMN

S101

4

C.L. COLUMN

FULL PEN TOP

AND BOTT.

FLANGE

BEAM - SEE PLAN

DOUBLE SIDED

SHEAR TAB WELDPLATES

EXTEND BOTTOM PLATES TO

FACE OF COLUMNS.

SEE PLAN AND SCHEDULE FOR

STEEL COLUMN.

TYPICAL DETAIL - HSSMOMENT CONNECTION AT COLUMN

S101

5

C.L. COLUMN

FULL PEN.

BRICK VENER -

SEE ARCH.

DWGS.

12"

5/16 3-12

5/16 3-12TYP.

HSS BEAM - SEE PLAN

Dwg.#

TYPICAL ROOF SECTION3/4" = 1'-0"

DRAWING5.DWGS101

6

ROOF SHEATHING - SEE GENERAL NOTES

ROOFING ITEMS - SEE

ARCH. DWGS.

COORDINATE WITH ARCH. DWGS.

BRICK VENEER - SEEARCH. DWGS.

BEAM - SEE PLAN

CONT. 2 x1.75 X 5.5" LVL

SQUASHBLOCKS BELOWEA. RAFTER

SIMPSON H3 HOLDDOWN, (2) EA. JOISTS

(9) 16 D x 3" NAILS

CONT. (2) 2 x 6 NAILER - ATTACH TO

BEAM WITH 12" DIA. (A307) BOLT @4'-0" O.C. MAX. AND WITHIN 6" FROM

EACH END OF BEAM