1
Photo A Showing location of proposed new shelter ;··>'1 1N•ne:o1i!ghbouring Property Existing bus stop markings burnt off. Plan Section of footpath planter broken out. New macadam hardstandlng formed. Roadside guardrailing maintained and altered - central section to be removed Bus stop markings relocated D IDIDI La Route des Quennevais Roadside guardrailing modified Clear footpath width maintained 1300 Clear footpath iil width maintained 0 1 2 3 I I I I I I I I I I UNEAR SCALE 1 :50 4 5n New prefabricated bus shelter in accordance with manufacturers All dimensions are to be checked on site before the commencement of any works including the order of materials. Any discrepancies are to be reported to the Architect. Do not scale from this drawing. Unless the title 'Contract' or 'Working' has been added to these drawings then these drawings are not for site use and we will accept no responsibility for errors or omissions, the drawing will also not be adjusted to include for SER requirements. This drawing is design copyright© Andrew Harvey Architects Ltd. Digimap Licence Number J48. Portions of this drawing may include intellectual property of the States of Jersey and are herein used by permission. Date: Revision Note: 3 Bay Fully Enclosed Bus Shelter Specification: Description: Dome Roof/3 Bay/Full End Panels/2 Front Openings Dimensions: 1300mm Wide x 3000mm Long x 2500mm High Seating: Length of Shelter/ 700mm from Ground Level Glazing: Roof - Bronze Tinted Polycarbonate Sides - 6mm TSG Colour: Dark green framing /"/--7"'- details 1300 Bus stop markings relocated Clear footpath width maintained a La Route des Quennevais North Elevation South Elevation East Elevation New prefabricated bus shelter in accordance with manufacturers dela"ls New prefabricated bus shelter in accordance with manufacturers details Section of footpath planter broken out. New macadam hardstanding formed. Bus stop marldngs relocated ===-- --=== === === === ===' === === 3000 7100 (Section of Railings Removed) West Elevation dient States of Jersey Transport & Technical Services project title New Bus Shelter at Stop No. 2542 (Don Farm) La Route des Quennevais St. Brelade drawing tltle Layout Plan, Elevations, Site Plan & scale(s): 1:50/1:100 Photo Consultation date: drawn: April 2016 R.M checked: Andrew Harvey Architects DDDDDDDDDDDDDDDDDDDDDDDDDDDDDD 1st Floor, Beresford House, Bellozanne Road, St. Helier, Jersey, JE2 3JW telephone: 01534 869291 facsimile: 01534 869293 drawing number: 11s1 I 01 I 02 mobile: 07797 740530 [email protected]

North Elevation South Elevation - Government of Jersey · North Elevation South Elevation East Elevation New prefabricated bus shelter in accordance with manufacturers dela"ls New

  • Upload
    others

  • View
    24

  • Download
    0

Embed Size (px)

Citation preview

Page 1: North Elevation South Elevation - Government of Jersey · North Elevation South Elevation East Elevation New prefabricated bus shelter in accordance with manufacturers dela"ls New

Photo A Showing location of proposed new shelter

;··>'1 1N•ne:o1i!ghbouring Property

Existing bus stop markings burnt off.

Plan

Section of footpath planter broken out. New macadam hardstandlng formed.

Roadside guardrailing maintained and altered -central section to be removed

Bus stop markings relocated

D

IDIDI

La Route des Quennevais

Roadside guardrailing modified

Clear footpath width maintained

1300

Clear footpath iil width maintained ~

0 1 2 3

I I I I I I I I I I

UNEAR SCALE 1 :50

4 5n

New prefabricated bus shelter in accordance with manufacturers

All dimensions are to be checked on site before the commencement of any works including the order of materials. Any discrepancies are to be reported to the Architect. Do not scale from this drawing. Unless the title 'Contract' or 'Working' has been added to these drawings then these drawings are not for site use and we will accept no responsibility for errors or omissions, the drawing will also not be adjusted to include for SER requirements. This drawing is design copyright© Andrew Harvey Architects Ltd. Digimap Licence Number J48. Portions of this drawing may include intellectual property of the States of Jersey and are herein used by permission.

Date: Revision Note:

3 Bay Fully Enclosed Bus Shelter Specification:

Description: Dome Roof/3 Bay/Full End Panels/2 Front Openings

Dimensions: 1300mm Wide x 3000mm Long x 2500mm High

Seating: Length of Shelter/ 700mm from Ground Level

Glazing: Roof - Bronze Tinted Polycarbonate Sides - 6mm TSG

Colour: Dark green framing

/"/--7"'- details ~~7 1300 (!~

Bus stop markings relocated

Clear footpath width maintained

a

La Route des Quennevais

North Elevation South Elevation

East Elevation New prefabricated bus shelter in accordance with manufacturers dela"ls

New prefabricated bus shelter in accordance with manufacturers details

Section of footpath planter broken out. New macadam hardstanding formed.

Bus stop marldngs relocated

===-- --=== === === === ===' === ===

3000 ~· 7100 (Section of Railings Removed)

West Elevation

dient

States of Jersey Transport & Technical Services

project title

New Bus Shelter at Stop No. 2542 (Don Farm) La Route des Quennevais

St. Brelade

drawing tltle

Layout Plan, Elevations, Site Plan &

scale(s):

1:50/1:100

Photo

Consultation

date: drawn:

April 2016 R.M checked:

Andrew Harvey Architects DDDDDDDDDDDDDDDDDDDDDDDDDDDDDD

1st Floor, Beresford House, Bellozanne Road,

St. Helier, Jersey, JE2 3JW

telephone: 01534 869291 facsimile: 01534 869293

drawing number:

11s1 I 01 I 02

mobile: 07797 740530 [email protected]