12
® NOISEBLOCK Modular Panel Enclosure Systems Commercial │ Industrial │ Environmental

NOISEBLOCK Modular Panel Enclosure Systems...4 Sound Transmission Class (STC) is determined by comparing test data with a set of standard STC contours as described in ASTM E413, Standard

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

  • ®

    NOISEBLOCK™ Modular Panel Enclosure SystemsCommercial │ Industrial │ Environmental

  • Noise control in commercial, industrial, or environmental systems is an important element of the design process. Whether it is to comply with municipal ordinances, conform to OSHA standards or to achieve occupant comfort, designing a system to the required noise level takes knowledge and experience. For over 55 years KINETICS NOISE CONTROL, INC. has been delivering noise control solutions to meet the needs of many industries.

    KINETICS designs and manufactures a complete line of modular engineered systems incorporating the NOISEBLOCK™ acoustic panel. This double-walled acoustic panel can be quickly and easily assembled into a variety of plenum, equipment enclosure, or process enclosure configurations; and are designed to provide a high level of sound absorption and transmission loss.

    KINETICS offers a complete design and engineering service, including acoustic, structural and ventilation provisions. This allows us to deliver custom, cost effective products and solutions that will fit your system and meet your needs.

    NOISEBLOCK™ Panel Systems: Commercial, Industrial, and Environmental Applications

    Commercial Applications

    The mitigation of noise from heating and cooling systems in modern commercial proj-ects is an important aspect in any building de-sign. KINETICS engineers and manufactures complete pressurized plenum enclosures for a wide array of HVAC installations. NOISBLOCK™ pressurized plenums are designed to provide effective noise control, structural integrity, along with full access for maintenance and inspection.

    Applications

    • Built-up and Custom Air Handlers• Double Wall Panel Duct• Fan Enclosures• HVAC Mixing Plenums• Mechanical Equipment• Relief / Outside Air Plenums• Supply / Return Plenums Field Assembled NOISEBLOCK™ AHU Casing

    02 l NOISEBLOCK™ Acoustic Panel Systems

  • KINETICS NOISE CONTROL, INC. l 03

    Industrial Applications

    Worker safety has taken on increasing impor-tance for industrial facilities, and as such, noise reduction initiatives have become an essential goal of the industry. Whether it is to comply with increasingly strict OSHA regulations, or to reduce hearing loss claims against an insurer, worker safety is now in the forefront. NOISEBLOCK™ enclosures are a key design element in bringing industrial, process and manufacturing facilities to safer noise levels and to help make a better work environment for all involved.

    Applications

    • Backup/Constant Power Generators• Compressors• In-Plant Offices• Manufacturing Equipment• Paint Booths• Positive Displacement Blowers• Processes• Test Chambers• Vacuum Blowers• Ventilation Fans• Pumps• Saws• Punch Presses

    In-Plant NOISEBLOCK™ Equipment Enclosure

    Environmental Applications

    With residential areas encroaching on industrial and commercial areas, environmental noise is a main concern for communities. It is common for commercial and industrial facilities to have mechanical or process equipment located out-side of the building, where the noise generated from this equipment was once not a concern, it is now. To mitigate outside noise sources a partial or complete NOISEBLOCK™ panel enclosure can be used. KINETICS engineers their enclosures with special design consider-ations for outdoor use, such as wind and snow loading, weather protection, proper roof design to avoid water pooling, waterproofing, and the use of special materials. KINETICS can provide a complete engineered system to account for all acoustic, structural and ventilation aspects.

    Applications

    • Air-Cooled Chillers• Cooling Towers• LNG Terminal Process Equipment• Wastewater Treatment Plant Process Blowers• Generators• Fans• Blowers

    Process Blower NOISEBLOCK™ Enclosure

  • 04 l NOISEBLOCK™ Acoustic Panel Systems

    NOISEBLOCK™ Panel Types

    Type STL acoustic panels are fabricated of various thicknesses and materials depending on the level of noise control required for a particular application. Standard KINETICS NOISEBLOCK™ type STL panels are fabricated with an outer solid shell of 18 gage and inner perforated shell of 22 gage steel. Panels are stiff-ened with 18 gage internal channels and edge rails. The acoustic grade fill is 2.5 to 6 pcf long strand fiberglass or mineral wool, depending on the application, are inert, mildew resistant, vermin proof and incombustible. Standard panels are 4" thick, but optional 2" and 6" panels are available to meet special requirements.

    Type HTL acoustic panels are designed for applications where a higher transmission loss is required. Standard KINETICS type HTL panels are fabricated with an outer solid shell of 16 gage and inner perforated shell of 22 gage steel with a high mass septum added for increased acoustic performance. Panels are stiffened with 18 gage internal channels and edge rails. The acoustic grade fill is 2.5 to 6 pcf long strand fiber-glass or mineral wool depending on the applica-tion and are inert, mildew resistant, vermin proof and incombustible. Panels are available in 4" or 6" thickness.

    Materials

    Outer and inner shell materials are available in standard galvanized steel, Type G90, mill phosphatized (satin) finish galvanized steel (readily paintable), stainless steel, Types 304 and 316, aluminum and aluminized steel. Standard material gages for solid outer shell are 18 ga. and 16 ga., perforated (23% open area) inner shell is 22 gage. Septum panels and panels with solid outer and inner shells are available. Factory applied powder-coat finish is available as an additional option.

    Typical STL panel detail: solid outer shell, me-dia, and perforated inner shell.

    All internal sound absorbing media used in NOISEBLOCK™ panels meet the requirements of NFPA-90A and surface burning characteris-tics per ASTM E84, with maximum flame spread rating of 25 and smoke developed rating of 50. Other media are available offering more stringent flame spread index and smoke devel-oped index. The media is available both unlined, lined or bagged using a specialized film or cloth barrier and acoustic spacer. The insulation is un-der compression so as not to allow settling of acoustic media within the panel.

    Typical groove and tongue (GT) panel joint

  • KINETICS NOISE CONTROL, INC. l 05

    Standard Panel Dimensions

    NOISEBLOCK™ acoustic panels are available in standard designated widths of 21.625" and 45.625", and standard lengths up to 144". Other width and lengths are available by special order. Most NOISEBLOCK™ enclosure and plenum systems incorporate as many standard panels as possible and then finished with non standard panels. For pressurized plenum systems the maximum panel width is determined by the internal operating static pressure (positive or negative), simply supported panel span and allowable panel deflection.

    Designated Panel Width

    Designated Panel Width

    Designated Panel Width

    GG Panel(Groove-Groove)

    GT Panel(Groove-Tongue)

    TT Panel(Tongue-Tongue)

    NOISEBLOCK™ Panel Joint

    Silenced Ventilation Systems

    KINETICS engineers will work with you to properly design wall or roof mounted, silenced forced/passive ventilation systems. KINETICS ensures the enclosed equipment or process is properly ventilated as to prevent overheating. KINETICS does this by choosing from our expansive product line of circular (VCS), rectan-gular straight (VRS) and elbow (VES) absorptive

    or reactive silencers and fixed-blade acoustic louvers (VAL/VAC/VPL). All are backed by inde-pendent testing per ASTM E477 and/or ASTM E90 in NVLAP accredited laboratories.

    Accessories

    NOISEBLOCK™ acoustic panel systems offer many accessory items: forced or passive silenced ventilation systems, windows, single and double leaf access doors, removable panel wall and roof sections, structural steel components, and factory painting.

    Panel connection style and width reference. Tongue and groove connections are standard for 16 gage shell and lighter. Heavier gages incorporate H-joiners.

  • 06 l NOISEBLOCK™ Acoustic Panel Systems

    Acoustic Performance Data

    Achievable Noise Reduction

    NOISEBLOCKTM enclosure systems offer typical noise reductions of 20-35 dBA. Special custom systems incorporating heavier (thicker gage) panel shell, thicker panels or an enclosure within an enclosure are available to achieve higher levels of noise reduction.

    When tested in accordance with ASTM E90, Standard Recommended Practice for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions, the panel assembly shall have the following minimum airborne sound transmission loss:

    The acoustic performance of NOISEBLOCK panel systems is not degraded through prolonged exposure to noise, vibration, pressure differential, dampness, wind, rain or snow.

    NOISEBLOCK panel acoustic performance is backed by independent testing in a NVLAP accredited laboratory. When tested in accordance with ASTM C423, Standard Method of Test for Sound Absorption of Acoustic Materials in Reverberant Rooms, the panel assembly shall have the following minimum airborne sound absorption:

    ModelSTL-21

    STL-21

    STL-42

    STL-42

    HTL-42

    Construction3

    18 ga. solid / 22 ga. perforated16 ga. solid / 22 ga. perforated18 ga. solid / 22 ga. perforated16 ga. solid / 22 ga. perforated16 ga. solid / 22 ga. perforated + septum

    1250.150.150.600.600.60

    2500.660.661.131.131.13

    5001.071.071.121.121.12

    10001.061.061.091.091.09

    20000.970.971.031.031.03

    40000.860.860.910.910.91

    NRC4

    0.950.951.001.001.00

    Sound Absorption

    1 (2) = 2-inch thickness2 (4) = 4-inch thickness3 solid inner skin available4 Noise Reduction Coefficient (NRC) is the average of coefficients at 250, 500, 1K and 2K Hz, expressed in the nearest integral multiple of 0.05.4 Sound Transmission Class (STC) is determined by comparing test data with a set of standard STC contours as described in ASTM E413, Standard Classification for Determination of Sound Transmission Class.

    ModelSTL-21

    STL-21

    STL-42

    STL-42

    HTL-42

    Construction3

    18 ga. solid / 22 ga. perforated16 ga. solid / 22 ga. perforated18 ga. solid / 22 ga. perforated16 ga. solid / 22 ga. perforated16 ga. solid / 22 ga. perforated + septum

    1251719212427

    2502325283234

    5003435394148

    10004748485161

    20005556566066

    40005760586670

    STC5

    3739404348

    Transmission Loss, dB

  • KINETICS NOISE CONTROL, INC. l 07

    Windows

    Observation windows are available as double-pane, wire reinforced, or tempered safety glass. The windows are held in place with a flexible acoustic, airtight seal and separated by an airspace of the same thickness as the NOISEBLOCK™ panel. Depending on window size it can be factory installed or shipped and field installed. High STC rated windows are available were maximum noise control is required.

    Doors

    A complete line of single and double leaf NOISEBLOCK™ access doors are available in various sizes and can be incorporated to meet a variety of needs such as personnel and machinery access. Single and double leaf access doors are available with industrial grade strap hinges (swing right/left, in/out) and panic/passage hardware (keyed locks or sliding hard-ware are available as an option). The maximum single leaf door size is 48" wide x 96" high and the maximum double leaf door size is 144" wide x 144" high. Door thicknesses match adjacent panel thickness, construction, and acoustic performace.

    Pressurized plenum single leaf doors are available in various sizes and have acoustic edge and bottom seals, doors are factory pre-hung, insulated and equiped with 2 or 3 strap hinges with Ventlok latches. (zinc and alu-minum non-corrosive alloy). Double-pane, wire reinforced view ports are an available option.

    Removable Panels

    NOISEBLOCK™ removable access panels for walls and roofs can be located and sized as required for easy access to interior equip-ment for maintenance, service, or repair. The construction of removable panels is the same as the surrounding panels. Depending on the size and frequency of use, removable panels incor-porate Ventlock latches or bolted connections. Roof access panels for outdoor applications can be designed for sloped roofs or can incorporate a rasied curb for flat roofs. Lifting lugs and special flashing are included as required.

    Structural Steel Components

    Structural steel components and welded as-semblies are designed for either field weld-ing or bolt together assembly. Standard structural items are shipped with one factory coat of primer for protection during shipping. KINETICS can supply structural items with hot-dip galvanized coated finish or factory painted with either a wet paint or powder-coat finish depending on size and specification.

    Thermal Performance

    The insulation materials used in NOISEBLOCK™ panels at 75˚F have maximum thermal conductance values of 0.06 BTU/hr-ft2-˚F (4" thick) and 0.12 BTU/hr-ft2-˚F (2 inch thick). Thermal resistance values are R17 (4" thick) and R8 (2" thick). Other insulation materials yielding higher thermal performance values are available.

  • Standard Construction and Connection Details

    08 l NOISEBLOCK™ Acoustic Panel Systems

    DETAIL 4 DETAIL 5

    CORNER DETAILCORNER ASSEMBLY DETAIL

    WALL PANEL TO BUILDING WALL

    DETAIL 7

    ROOF PANEL TO BUILDING CEILING

    DETAIL 12

    INTERIOR PANEL CONNECTION

    DETAIL 9

    WALL PANEL TO BUILDING CEILING

    DETAIL 8

    DETAIL 11

    DRIP SHIELD DETAIL

    DETAIL 6

    DETAIL 10

    REDUCED CLEARANCEOUTSIDE TRIM DETAIL

    T & G PANEL ASSEMBLY DETAIL

    DETAIL 1 DETAIL 2

    WALL TO CURB DETAIL

    DETAIL 3

    BASE CHANNEL CORNER DETAIL

    OUTSIDE TRIM CORNER DETAIL

    GROOVE

    TONGUE

    TEKSCREW

    CONTINUOUSDOUBLE BEADOF CAULKAPPLIED INSIDE

    WALL PANEL

    CONTINUOUSBEAD OF

    CAULK(3 PLACES)

    FLOORCHANNEL

    TEK SCREW

    CONCRETE CURBOPTIONAL

    ANCHORS(BY OTHERS)

    ANCHORS(BY OTHERS)

    MITERED(BY OTHERS)

    FLOORCHANNEL

    CONTINUOUSBEADS OF CAULK

    CONCRETE CURBOPTIONAL

    CONTINUOUSBEAD OFCAULK

    CONCRETE CURBOPTIONAL

    INSIDE TRIM

    OUTSIDE TRIM

    PANELS MEETINGAT CORNER

    CONTINUOUSBEAD OF CAULK

    OUTSIDE TRIM

    TEK SCREW INSIDE TRIM

    MITERED (BY OTHERS)

    TEK SCREW

    OUTSIDETRIM

    OUTSIDE TRIM

    TEK SCREWTEK SCREW

    TEK SCREW

    TEK SCREWTEKSCREW

    TEK SCREW

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OF CAULK

    ANCHORS(BY OTHERS)

    ANCHORS(BY OTHERS)

    ANCHORS(BY OTHERS)

    ANCHORS(BY OTHERS)

    CONTINUOUSBEAD OF

    CAULK

    CONCRETE CURBOPTIONAL

    EXISTING WALL

    FLASHING

    EXISTING CEILING

    10GA SPECIALANGLE 2" X 4"

    H-CHANNEL

    INSIDETRIM

    TRIM

    10GA SUPPORT ANGLE

    EXISTINGWALL

    DRIP SHIELD

    DRIP SHIELD

    TOP OF DOOR OPENING

    FLOOR CHANNELOUTSIDE TRIMSPOT WELDED

    TO CHANNEL

    INSIDE TRIM

    EXISTINGWALL

  • KINETICS NOISE CONTROL, INC. l 09

    CONTINUOUSBEAD OFCAULK

    WALL PANEL TO HSS COLUMN

    G GT T

    DETAIL 20

    FIELD CUT FLASHING DETAIL

    DETAIL 15

    WALL TO ROOF JOINT

    DETAIL 17

    STRUCTURAL ROOF SUPPORT

    DETAIL 18

    90° ROOF OFFSET WITH SUPPORT

    DETAIL 13

    GRAVEL STOP (OUTDOOR) DETAIL

    DETAIL 14

    INTERMEDIATE DECK DETAIL

    DETAIL 16

    FLOOR PANELS

    SINGLE DOOR IN PANELACOUSTICAL LOUVER INSTALLATION

    DETAIL 19

    DETAIL 22 DETAIL 23 DETAIL 24

    ACOUSTICAL DOUBLE DOOR

    DETAIL 21

    DOWNBLAST CENTRIFUGAL EXHAUSTER

    OUTSIDE TRIM

    TEK SCREW

    CONTINUOUSBEAD OF CAULK

    INSIDE TRIM

    GRAVEL STOP

    CONTINUOUSBEAD OF CAULK

    INSIDE TRIM

    INSIDE TRIM

    INSIDE TRIM

    TEK SCREW

    TEK SCREW

    TEK SCREW

    TEK SCREW

    TEK SCREW

    TEK SCREW

    TEK SCREW

    TEK SCREW

    OUTSIDE TRIM

    OUTSIDE TRIM

    OUTSIDE TRIM

    OUTSIDETRIM

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OFCAULK

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OF CAULK

    CONTINUOUSBEAD OFCAULK

    CONTINUOUSBEAD OF

    CAULK

    CONTINUOUSBEAD OF CAULK CONTINUOUS BEAD

    OF CAULK

    CONTINUOUSBEAD OFCAULK

    CONTINUOUS BEAD OF CAULK

    CONTINUOUSBEAD OFCAULK

    BUILT-UP ROOF(BY OTHERS)

    FLOORCHANNEL

    DECKPANEL

    COVER TRIM

    WALL PANEL(UPPER)

    WALL PANEL(LOWER)

    ROOF PANEL

    ROOF PANEL

    ROOF PANEL

    ROOF PANEL

    W-BEAM

    FLOOR CHANNEL

    COVER TRIM

    W-BEAM

    TACK WELDTOP OF BEAM

    TO ROOF PANELS H-CHANNEL

    PIPE SUPPORTSCREWADJUSTMENT

    ANCHORS(BY OTHERS)

    SEALER INSIDEH-CHANNEL

    TACK WELDTOP PLATE

    TO W-BEAMPIPE SUPPORT

    CONCRETE CURB/FLOOR(BY OTHERS)

    FLOORCHANNEL WALL PANEL

    FLOOR PANEL

    ANGLES WELDEDTO COLUMN

    INSIDE

    HSS COLUMN

    TRIM

    FIELD CUT TO FIT

    FLAT FLASHING(FIELD CUT)

    TRIM

    DOWNBLASTCENTRIFUGALEXHAUSTER

    FLO

    W

    FLANGE

    FLASHING(OPTIONAL)

    ACOUSTICLOUVER

    KNEE BRACE(IF REQUIRED)

    PANELS

    HEAVY DUTYSPRING ORCHAIN BOLTWINDOW

    (OPTIONAL)

    HEAVY DUTY STRAPOR CAMLIFT HINGES

    INSIDERELEASE

    DOOR GASKET REFRIGERATOR LATCH

    COMPRESSIONLATCH

    ACOUSTICPANEL

    STRAP HINGE

    DOOR

    STRAP HINGECOMPRESSION LATCH

    WINDOW(OPTIONAL)

  • Engineering Services

    10 l NOISEBLOCK™ Acoustic Panel Systems

    Structural Performance

    NOISEBLOCK™ acoustic panel enclosures and plenum systems are structurally designed for internal and external loading (± internal static pressure, wind loads, snow loads, live and dead loads as well as seismic) per industry standards following the applicable IBC building codes. Available options include copies of the structural steel calculations and PE stamp. KINETICS engineering group uses the latest AutoCAD soft-ware and can incorporate your equipment or system AutoCAD layout into our submittals to assure proper clearances and access locations.

    Installation Guidelines

    KINETICS supplies complete AutoCAD submit-tal, piece-marked installation drawings and bill of materials which correspond to the factory piece-marked panel system components. This piece-marking notation allows for easy installa-tion of any system by referencing the numbers associated on the project specific assembly drawings and details. Typcial enclosure and plenum systems incorporate six standard com-ponents, NOISEBLOCK™ tongue and groove panels, base channel, inside and outside trim pieces, fasteners, sealant and door(s).

    1. Review the KINETICS supplied job specific, piece-marked, installation drawings and compare against the supplied bill of materials.

    2. Prior to delivery of product, clear an area near where the panels are to be installed so they can be conveniently stored. To save time and labor move panels directly from the truck to this area. Make sure the necessary material handling equipment is available, including lifts for unloading and carts for moving panels across the floor to the installation site.

    3. Near the installation area stack the panels on end and lengthwise with piece marks exposed. This will save time from moving and restacking panels as the enclosure is installed. If more than one enclosure is in-volved separate panels by drawing number as referenced on the bill of materials.

    Installation Planning Tips

    4. Typical tools and equipment required for successful installation are: ladder, extension cord, lifts, portable lighting, masonry and metal drill, metal cutting saw, tape measure, caulking gun, come a long.

    5. Summary of Installation:• Locate base channel• Set corner panels• Install wall, partition and door panels• Add wall trim inside and outside• Install structural components (if required)• Add roof panels• Add roof trim inside and outside• Complete enclosure

  • KINETICS NOISE CONTROL, INC. l 11

    Packaging

    NOISEBLOCK™ panel systems are knocked-down (unassembled), standard palletized, banded and shrink wrapped before shipping. All panels, trim items including optional items are piece-marked to cor-respond to piece-marked installation drawings and details supplied with every order. Inside and outside trim are supplied in standard 10’-0” lengths to be field cut to required lengths. Standard shipments are sent in a closed trailer but flatbed shipments are available per special request.

    Standard Skid Packaging Export Crate Packaging

    Finish

    NOISEBLOCK panel systems are available factory powder-coat finish per selection of POWDURA® RAL Series Super Durable TGIC FREE Polyester Powder Coatings, color matching or mill/unpainted.

  • NPE │ 04/19Kinetics Noise Control, Inc. is continually upgrading the quality of our products. We reserve the right to make changes to this and all products without notice.

    MADE IN USA

    kineticsnoise.com/[email protected]®