DS 0.72" DS Layer 1: AGC ComfortSelect 36 (e=0.036*, #2) ZF-S: Super Spacer Premium NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT Rendered to: EARTHWISE GROUP, LLC SERIES/MODEL: 623.620 Patio Door 90% Argon* TYPE: Sliding Patio Door 0.27 Reference must be made to Report No. D7298.03-116-46, dated 03/27/15 for complete test specimen description and data. Summary of Results Standardized Thermal Transmittance (U-Factor) Gap 1: Clear Unit Size: 78-3/4" x 78-3/4" (2000 mm x 2000 mm) (Model Size) Layer 2: 130 Derry Court York, PA 17406 p. 717.764.7700 f. 717.764.4129 www.archtest.com www.intertek.com/building

NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

  • Upload
    buitu

  • View
    223

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

DS0.72"DS

Layer 1: AGC ComfortSelect 36 (e=0.036*, #2)ZF-S: Super Spacer Premium

NFRC 102-2010 THERMAL PERFORMANCETEST REPORT

Rendered to:

EARTHWISE GROUP, LLC

SERIES/MODEL: 623.620 Patio Door

90% Argon*

TYPE: Sliding Patio Door

0.27

Reference must be made to Report No. D7298.03-116-46, dated 03/27/15 for complete testspecimen description and data.

Summary of ResultsStandardized Thermal Transmittance (U-Factor)

Gap 1:Clear

Unit Size: 78-3/4" x 78-3/4" (2000 mm x 2000 mm) (Model Size)

Layer 2:

130 Derry CourtYork, PA 17406

p. 717.764.7700f. 717.764.4129

www.archtest.com www.intertek.com/building

Page 2: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Report Number:Test Date:

Report Date:

78-3/4" x 78-3/4" (2000 mm x 2000 mm) (Model Size)

NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT

5796 Cedarview Court

Series/Model:

Overall Size:

Test Sample Identification:

Sliding Patio Door

D7298.03-116-46

623.620 Patio Door

Type:

Test Procedure: U-factor tests were performed in a Guarded Hot Box in accordance withNFRC 102-2010, Procedure for Measuring the Steady-State Thermal Transmittance ofFenestration Systems .

Btu/hr·ft2·F (CTS Method)Standardized U-factor (Ust):

This report is a reissue of the original Report No. D7298.01-116-46. This report is reissued inthe name of Earthwise Group, LLC through written authorization of Deceuninck NorthAmerica, LLC.

Test Results Summary:

The Energex Winodw Alliance - Bensalem, Pennsylvania

0.27

NFRC Standard Size:

Test Sample Submitted by:

Test Sample Submitted for: Validation for Recertification (Production Line Unit) no Plant Qualification

Liberty Township, Ohio 45044

Rendered to:

EARTHWISE GROUP, LLC

03/27/1503/19/15

78.7" x 78.7" (2000 mm wide x 2000 mm high)

130 Derry CourtYork, PA 17406

p. 717.764.7700f. 717.764.4129

www.archtest.com www.intertek.com/building

Page 3: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Test Sample Description:

*Stated per Client/Manufacturer N/A Non-Applicable

VinylMitered / Welds / Unsealed

N/AGlazing Method:Exterior Finish:

White Interior Finish:

White

Vinyl

AGC ComfortSelect 36 (e=0.036*, #2)90% Argon*

Single-Probe Method*

Gap 1:DS

0.72"DS

Gas Fill Method:

Daylight Opening:

Active Panel:

VinylExterior Finish:

Material:

Glazing Method:

White

Material:

31-3/4" x 67-3/4"White

Exterior39-7/8" x 75-7/8"

Page 2 of 8

78-3/4" x 78-3/4" (Model Size)

Frame:VY: Vinyl

D7298.03-116-46

Daylight Opening:

31-3/4" x 67-3/4"

WhiteWhite

39-7/8" x 75-7/8"Material:

Daylight Opening:Vinyl

Interior Finish:

*EPS foam located in all panel cavities

Size:

VI: Vinyl with Reinforcement - Interlock (Aluminum)*

ExteriorSize:

Corner Joinery:

Exterior Color:Interior Color:

Vinyl

Exterior Color:Interior Color:Corner Joinery:

Interior Finish:

Mitered / Welds / Unsealed

VP: Vinyl with Reinforcement - Partial*Size:

Exterior Color:

ZF-S: Super Spacer PremiumClear

Exterior Finish:

Corner Joinery:

Layer 1:

Glazing Method:

Vinyl

N/A

Coped / Screws / Sealed

Fixed Panel:

Glazing Information:

Layer 2:

Interior Color:

*Aluminum reinforcement in stiles and bottom rail*EPS foam located in all panel cavities

Page 4: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Test Sample Description: (Continued)

Weatherstripping:

Hardware:

Drainage:

Weepslot

Polypile with center fin

2 Screen track

4

Roller assembly

Metal handle lock assembly

0.50" x 0.50" 4

LocationDrainage Method

Bottom corners of each panel

Fixed panel track sill

Inactive jambs and fixed panel track head3

1 set

Metal keeper

Weep notch 1.00" x 0.13"

1.00" x 0.25"

Size

Sill face and active panel track sill

1Aluminum threshold

Weephole

Aluminum snubber 1

Vinyl insert

Quantity

Polypile with center fin 2 rows Jambs

Lock jamb

Polypile pad

Description

1 Lock stile

1

Bottom corners of active panel

1 row Fixed and active meeting stile

2 Fixed meeting stile

Quantity Location

Quantity

Polypile with center fin

D7298.03-116-46Page 3 of 8

3 rows

LocationDescription

Head and sill

2 Fixed and active meeting stile

Fixed panel track jamb

Fixed panel retainer clip 2 Top and bottom of fixed meeting stile

Fixed panel riser 1 Fixed panel track sill

Vinyl interlock

Page 5: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Measured Test Data

Heat Flows1. Total Measured Input into Metering Box (Qtotal) Btu/hr 2. Surround Panel Heat Flow (Qsp) Btu/hr 3. inches4.5. Metering Box Wall Heat Flow (Qmb) Btu/hr 6. EMF vs Heat Flow Equation (equivalent information) 0.0115*EMF + -0.0177. Flanking Loss Heat Flow (Qfl) Btu/hr 8. Net Specimen Heat Loss (Qs) Btu/hr

Areas1. Test Specimen Projected Area (As) ft2

2. Test Specimen Interior Total (3-D) Surface Area (Ah) ft2

3. Test Specimen Exterior Total (3-D) Surface Area (Ac) ft2

4. Metering Box Opening Area (Amb) ft2

5. Metering Box Baffle Area (Ab1) ft2

6. Surround Panel Interior Exposed Area (Asp) ft2

Test Conditions1. Average Metering Room Air Temperature (th) F2. Average Cold Side Air Temperature (tc) F3. Average Guard/Environmental Air Temperature F4. Metering Room Average Relative Humidity %5. Metering Room Maximum Relative Humidity %6. Metering Room Minimum Relative Humidity %7. Measured Cold Side Wind Velocity (Perpendicular Flow) mph8. Measured Warm Side Wind Velocity (Parallel Flow) mph9. Measured Static Pressure Difference Across Test Specimen 0.00" ± 0.04"H2O

Average Surface Temperatures1. Metering Room Surround Panel F2. Cold Side Surround Panel F

Results

Thermal Transmittance (U-factor)

899.16

Btu/hr·ft2·F0.0236

75.1170.84

10.05

69.80

32.04

Thermal Transmittance of Test Specimen (Us)0.27

68.19-0.22

9.66

1.

71.26

12.66

9.86

-0.38

51.688.00

10.41

NA

50.11

829.47

43.0748.77

7.59

Surround Panel ConductanceSurround Panel Thickness

Page 4 of 8D7298.03-116-46

Btu/hr·ft2·F0.272. Standardized Thermal Transmittance of Test Specimen (Ust) Btu/hr·ft2·F

Page 6: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Calculated Test Data

CTS Method1. Warm Side Emittance of Glass (e1)2. Cold Side Emittance of Glass3. Warm Side Frame Emittance*4. Cold Side Frame Emittance*5. Warm Side Sash/Panel/Vent Emittance*6. Cold Side Sash/Panel/Vent Emittance*7. Warm Side Baffle Emittance (eb1)8. Cold Side Baffle Emittance (eb2)9. Equivalent Warm Side Surface Temperature F

10. Equivalent Cold Side Surface Temperature F11. Warm Side Baffle Surface Temperature F12. Cold Side Baffle Surface Temperature F13. Measured Warm Side Surface Conductance (hh)14. Measured Cold Side Surface Conductance (hc)15. Test Specimen Thermal Conductance (Cs)16. Convection Coefficient (Kc) Btu/(hr·ft2·F1.25)17. Radiative Test Specimen Heat Flow (Qr1) Btu/hr18. Conductive Test Specimen Heat Flow (Qc1) Btu/hr19. Radiative Heat Flux of Test Specimen (qr1)20. Convective Heat Flux of Test Specimen (qc1)21. Standardized Warm Side Surface Conductance (hsth)22. Standardized Cold Side Surface Conductance (hstc)23. Standardized Thermal Transmittance (Ust)

Test Duration1.2.

*Stated per NFRC 101

9.1810.08

Btu/hr·ft2·F

N/A

3.49

395.30Btu/hr·ft2·F

Btu/hr·ft2·F

0.92

55.55

N/A

Page 5 of 8

The thermal performance test results were derived from 02:03 hours, 03/19/15 to 06:03hours, 03/19/15.

Btu/hr·ft2·F4.970.37

0.27

The environmental systems were started at 17:13 hours, 03/18/15.

Btu/hr·ft2·FBtu/hr·ft2·F

5.28

Thermal Transmittance (U-factor)

The test parameters were considered stable for two consecutive four hour test periodsfrom 22:03 hours, 03/18/15 to 06:03 hours, 03/19/15.

1.18 Btu/hr·ft2·F

68.78

434.17

0.900.90

1.35

The reported Standardized Thermal Transmittance (Ust) was determined using CTS Method,per Section 8.2(A) of NFRC 102.

3.

Btu/hr·ft2·F

0.84

D7298.03-116-46

0.84

0.900.90

0.33

Page 7: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Glass collapse determined using a digital glass and air space meter

ANSI/NCSL Z540-2-1997 type B uncertainty for this test was 1.62%.

The test sample was installed in a vertical orientation, the exterior of the specimen was exposedto the cold side. The direction of heat transfer was from the interior (warm side) to the exterior(cold side) of the specimen. The ratings were rounded in accordance to NFRC 601, NFRC Unitand Measurement Policy. The data acquisition frequency is 5 minutes.

“This test method does not include procedures to determine the heat flow due to either airmovement through the specimen or solar radiation effects. As a consequence, the thermaltransmittance results obtained do not reflect performances which are expected from fieldinstallations due to not accounting for solar radiation, air leakage effects, and the thermal bridgeeffects that have the potential to occur due to the specific design and construction of thefenestration system opening. The latter can only be determined by in-situ measurements.Therefore, it is important to recognize that the thermal transmittance results obtained from thistest method are for ideal laboratory conditions and should only be used for fenestration productcomparisons and as input to thermal performance analyses which also include solar, air leakageand thermal bridge effects.”

0.78"0.84"

Page 6 of 8

Glazing Deflection:

D7298.03-116-46

Fixed Panel

Center gap width at laboratory ambientconditions on day of testing

The sample was inspected for the formation of frost or condensation, which may influence thesurface temperature measurements. The sample showed no evidence of condensation/frost atthe conclusion of the test.

Active Panel

Estimated center gap width upon receipt ofspecimen in laboratory (after stabilization)

Edge Gap Width

0.78"

0.72" 0.72"

0.84"

0.72" 0.66"Center gap width at test conditions

Required annual calibrations for the Architectural Testing Inc. 'thermal test chamber' (ICN000001) in York, Pennsylvania were last conducted in May 2014 in accordance withArchitectural Testing Inc. calibration procedure. A CTS Calibration verification was performedDecember 2014. A Metering Box Wall Transducer and Surround Panel Flanking LossCharacterization was performed December 2014.

Page 8: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

For ARCHITECTURAL TESTING, INC.

Tested By: Reviewed By:

Ryan P. Moser Shon W. EinsigSenior Technician Senior Technician

Individual-In-Responsible-Charge

RPM:klbD7298.03-116-46

Attachments (pages): This report is complete only when all attachments listed are included.

Submittal Form and Drawings (15)Baffle Wiring Diagram (1)

D7298.03-116-46

"Ratings included in this report are for submittal to an NFRC licensed IA for certificationpurposes and are not meant to be used for labeling purposes. Only those values identified on avalid Certification Authorization Report (CAR) are to be used for labeling purposes."

Page 7 of 8

Architectural Testing, Inc. will service this report for the entire test record retention period. Testrecords that are retained such as detailed drawings, datasheets, representative samples of testspecimens, or other pertinent project documentation will be retained by Architectural Testing,Inc. for the entire test record retention period. The test record retention end date for this reportis March 19, 2019.

This report is a reissue of the original Report No. D7298.01-116-46. This report is reissued inthe name of Earthwise Group, LLC through written authorization of Deceuninck NorthAmerica, LLC.

Appendix-A: Appendix-B:

Architectural Testing, Inc. is accredited by the International Accreditation Service (IAS) under thespecific test methods listed under lab code TL-144, in accordance with the recognizedInternational Standard ISO/IEC 17025:2005. The laboratory’s accreditation or test report in noway constitutes or implies product certification, approval, or endorsement by IAS.

CTS Calibration Data (1)

This report does not constitute certification of this product nor an opinion or endorsement bythis laboratory. It is the exclusive property of the client so named herein and relates only to thespecimen tested. This report may not be reproduced, except in full, without the writtenapproval of Architectural Testing, Inc.

Appendix-D:

Surround Panel Wiring Diagram (1)Appendix-C:

Page 9: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Page 8 of 8

.03R0

Revision(s)

Revision Log

03/27/15

Rev. #

Original Report Issue - Reissue of Report No.D7298.01-116-46 in the name of EarthwiseGroup, LLC.

Date

D7298.03-116-46

Page(s)

All

This report produced from controlled document template ATI 00025(a), revised 03/14/2013.

Page 10: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

CTS Test DateCTS Size ft2

CTS Glass/Core ConductanceWarm Side Air Temperature FCold Side Air Temperature FWarm Side Average Surface Temperature FCold Side Average Surface Temperature FConvection Coefficient (Kc)Measured Cold Side Surface Conductance (hc)Measured Thermal Transmittance

4.

1.2. 43.06

05/11/14

69.803. 0.42

D7298.03-116-46Appendix A: CTS Calibration Data

Btu/hr·ft2·F

8. 0.33

5. -0.396. 54.35

Btu/hr·ft2·F

3.88

9. 4.9710. 0.30 Btu/hr·ft2·F

7.Btu/(hr·ft2·F1.25)

Page 11: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

+1 +2 +3

+4 +5

+6 +7 +8

D7298.03-116-46Appendix B: Surround Panel Wiring Diagram

Page 12: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

+1 +2 +3 +4 +5 +6 +7 +8 +9 +10 +11 +12 +13 +14 +15 +16 +17 +18 +19 +20 +21 +22 +23 +24 +25 +26 +27 +28 +29 +30

Appendix C: Baffle Wiring DiagramD7298.03-116-46

Page 13: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

Appendix D: Submittal Form and DrawingsD7298.03-116-46

Page 14: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA
Page 15: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA
myingst
Text Box
No Aluminum Reinforcement in this Sash
myingst
Line
myingst
Rejected
myingst
Rejected
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Rectangle
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Line
myingst
Text Box
EPS Foam Locations
myingst
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
Line
rmoser
New Stamp
rmoser
Rejected
rmoser
Rejected
rmoser
Rejected
rmoser
Rejected
rmoser
Rejected
Page 16: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

ITEM NO. DESCRIPTION QUANTITY FAB DWG. NO SOURCE

1 HEAD 1 10001100-F-01 A2 JAMB 2 10001100-F-05 A3 EXTERIOR FRAME COVER 1 10001104-F-01 A4 INTERIOR FRAME COVER 2 STRAIGHT CUT A5 SILL 1 10001101-F-01 A6 SILL THRESHOLD 1 10300171-F-01 PPPP7 SILL RISER 1 10001105-F-01 A8 WEATHER-STRIPPING - .270 x .250 AS REQ'D HHHH9

10 MISC SNUBBER 2 10300148-F-01 PPPP11 ROLLER TRACK CAP 1 STRAIGHT CUT N12 L - BRACKET 2 LLLL13 SILL FRAME GASKET 2 CC1415 KEEPER 1 F16 2778 KEEPER - YZD MILD STEEL17 2778 KEEPER - STAINLESS STEEL18 SCREEN KEEPER 1 MMMM19 BUMPER STOP 2 F2021 SCREWS SNUBBER 1622 L - BRACKET - HEAD & SASH 823 L - BRACKET - HEAD & SASH 424 KEEPER (INSTALLATION) 225 SILL RISER 426 FRAME ASSEMBLY 1227 SCREEN KEEPER 2282930

REV DATE DESCRIPTION BY

NAME:

CONFIDENTIAL DWN BY: JGMUNPUBLISHED WORK © 2008 CHKD BY:

DECEUNINCK NORTH AMERICA DWG NO:

QUAS CANLK

DECU-2808-00

#8 x 1.25" PFH - ZINC#8A x 1" PFH - ZINC

DECU-2808-84011H0402152.525

10001105W21255MW

1030014816719-01011H027

623.000 PD - 005

623000PD-005

623.000 PD - 005 - BILL OF MATERIALS 2 LITE

100011001000110010001104

PART NO.

100011041000110110300171

#8 x 2.5" PFH - ZINC#8 x 2.5" PFH - ZINC

#8 x 1.25" PFH - ZINC

THIS DOCUMENT CONTAINS PROPRIETARY AND CONFIDENTIAL INFORMATION. DO NOT COPY OR DISCLOSE THIS INFORMATION WITHOUT THE EXPRESS WRITTEN CONSENT OF DECEUNINCK NORTH AMERICA. DECEUNINCK NORTH AMERICA RESERVES THE RIGHT TO CHANGE THIS DRAWING AND ANY ASSOCIATED DOCUMENTS.

#8 x 3" PPH - ZINC#6 x .375" PPH

MONROE, OH COPYRIGHT 2008

rmoser
New Stamp
Page 17: NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT … · NFRC 102-2010 THERMAL PERFORMANCE TEST REPORT ... "Ratings included in this report are for submittal to an NFRC licensed IA

ITEM NO. DESCRIPTION QUANTITY FAB DWG. NO SOURCE

1 FXD PNL TOP RAIL 1 10001102-F-01 A2 STILE 2 10001102-F-01 A3 BOTTOM RAIL 1 10001102-F-02 A4 INTERLOCK 1 10001117-F-04 A5 SCREW COVER 1 STRAIGHT CUT A6 GLAZING BEAD 4 10001111-F-01 A7 STILE REINFORCEMENT - JAMB 1 STRAIGHT CUT PPPP8 STILE REINFORCEMENT - INTERLOCK 1 STRAIGHT CUT PPPP9 WEATHER-STRIPPING - .270 x .250 AS REQ'D HHHH1011 OPR PNL RAIL - TOP 1 10001102-F-01 A12 STILE - INTERLOCK 1 10001102-F-03 A13 STILE - LOCK 1 10001102-F-04 A14 RAIL - BOTTOM 1 10001102-F-05 A15 INTERLOCK 1 10001117-F-02 A16 SCREW COVER 1 STRAIGHT CUT A17 GLAZING BEAD 4 10001111-F-01 A18 STILE REINFORCEMENT - INTERLOCK 1 STRAIGHT CUT PPPP19 STILE REINFORCEMENT - LOCK 1 10300150-F-01 PPPP20 RAIL REINFORCEMENT - BOTTOM 1 10300150-F-01 PPPP21 WEATHER-STRIPPING - .270 x .250 AS REQ'D HHHH2223 MISC LOCK SET ASSEMBLY - 2817 LOCK W/ TRIMPLATE 1 AMESBURY F24 HANDLE SET ASSEMBLY 1 AMESBURY F25 HANDLE SET - INTERIOR SWITCH AMESBURY26 HANDLE SET - INTERIOR SWITCH / KEY27 HANDLE SET - BLANK28 ROLLER ASSEMBLY - PRECISION 1.66" WHEEL 2 F29 DRAFT PLUG - .810 DIA. 2 HHHH30 3/8" HOLE PLUG 2 D31 IMPACT BRACKET 2 MMMM32 1" INSULATED GLASS - NOTE 233 SETTING BLOCKS (REFER TO IG SUPPLIER GUIDELINES) AS REQ'D34 GLAZING COMPOUND AS REQ'D VENTURE TAPE3536 SCREWS LOCK SET 237 ROLLER ASSEMBLY 438 FIXED PANEL TO JAMB 1039 REINFORCMENT TO PANEL AS REQ'D40 INTERLOCK AS REQ'D41 IMPACT BRACKET 642

NOTE LAMINATED GLASS UTILIZES .090" SOLUTIA PVBREV DATE DESCRIPTION BY

NAME:

CONFIDENTIAL DWN BY: JGMUNPUBLISHED WORK © 2008 CHKD BY:

DECEUNINCK NORTH AMERICA DWG NO:

000.620 PD - 006

000620PD-006

10300151

#8 x 1" PFH - ZINC

9946011H055-D

REFER TO APPLICABLE TEST REPORT

#8 x 1" PPH - ZINC#8 x .75" PFH - PAINTED

1000111710001118

DECU-XXX3

W21255MW

2806/2957-01DECU-XXX1DECU-XXX2

W21255MW

10001102

1000111110300150

10001102

1939-6011-TRUTH

10001102

1000111810001111

THIS DOCUMENT CONTAINS PROPRIETARY AND CONFIDENTIAL INFORMATION. DO NOT COPY OR DISCLOSE THIS INFORMATION WITHOUT THE EXPRESS WRITTEN CONSENT OF DECEUNINCK NORTH AMERICA. DECEUNINCK NORTH AMERICA RESERVES THE RIGHT TO CHANGE THIS DRAWING AND ANY ASSOCIATED DOCUMENTS.

#8 x .75" PPH - ZINC

DECU-XXX4 ADH-3006

REFER TO APPLICABLE TEST REPORT

MONROE, OH COPYRIGHT 2008

REFER TO APPLICABLE TEST REPORT

#8 x 3" PFH - PAINTED

#8 x 1.5" PFH - ZINC

000.620 PD - 006 - BILL OF MATERIALS 2 LITE

103001501030015010300150

1000110210001117

PART NO.

100011021000110210001102

myingst
Text Box
1300151
myingst
Line
myingst
Line
rmoser
New Stamp