4
SURETECH Instruments Newsletter March 2016 1 SURE Engineering keeps you up to date with Electrical Sensing and Safety Equipment March 2016 SURETECH Instruments are manufactured by SURE Engineering March 2016 SURETECH showcases our South African designed and manufactured range of transducers and sensors - now available for your everyday tasks of measuring electrical parameters such as voltage, current, kW, kVA, kVARs, power factor, frequency, kWH etc. Leading edge Rogowski Current Sensor for measuring electrical parameters RCS General Features: Moulded in solid resin for ruggedness, reliability, long life, stability and easy application Rubberised strain relief Coaxial cable tail provides interface to integrator BNC connector available as flying lead OR panel mount, OR none Accuracy 0.5% Standard cable tail length: 300mm (other lengths available on request) Electrostatic shielded to operate in high dv/dt applications Split-core versions are available, but are more expensive and generally less accurate Insulation voltage is 1000 volts standard, higher available on order RCS sensors can be supplied with Rogowski signal processing or stand alone Galvanic isolation from HV source

Newsletter_201603 Erica

Embed Size (px)

Citation preview

Page 1: Newsletter_201603 Erica

SURETECH Instruments Newsletter March 2016

1

SURE Engineering keeps you up to date with Electrical Sensing and Safety Equipment

March 2016

SURETECH Instruments

are manufactured by SURE Engineering

March 2016

SURETECH showcases our South African designed and manufactured range of transducers and sensors - now available for your everyday tasks of measuring electrical parameters such as voltage, current, kW, kVA, kVARs, power factor, frequency, kWH etc.

Leading edge Rogowski Current Sensor for measuring

electrical parameters

RCS General Features: • Moulded in solid resin for ruggedness,

reliability, long life, stability and easy application

• Rubberised strain relief

• Coaxial cable tail provides interface to integrator

• BNC connector available as flying lead OR panel mount, OR none

• Accuracy 0.5%

• Standard cable tail length: 300mm (other lengths available on request)

• Electrostatic shielded to operate in high dv/dt applications

• Split-core versions are available, but are more expensive and generally less accurate

• Insulation voltage is 1000 volts standard, higher available on order

• RCS sensors can be supplied with Rogowski signal processing or stand alone

• Galvanic isolation from HV source

Page 2: Newsletter_201603 Erica

SURETECH Instruments Newsletter March 2016

2

Rogowski Current Sensor : � SURETECH RCS sensors can be used in a wide range of measurement

applications, including power � frequencies, high frequency and pulse applications, such as measuring gate current

on SCRs and GTOs, � IGBTs etc in power electronics drive systems � SURETECH RCS bandwidth is very wide extending well beyond 1MHz. Rogowski

technology does not respond � to DC (zero output at zero frequency input), but the sensors are very useful to

measure the AC current � components on a DC line � SURETECH RCS sensors have been value engineered for cost effectiveness, even

in applications that require � sensing points to be installed for later maintenance / monitoring; (without installing an

integrator at every � sensor). This feature is extremely useful to improve maintainability in motor drives

and power electronic � systems � SURETECH RCS sensors are available in various formats, sizes, insulation levels,

bandwidths etc

Everyone needs TRANSDUCERS for measuring electrical parameters

Transducer General Features: • Standard transducer enclosure for simple

mounting (125mmx70mmx117mm)

• Flexible enclosure sizes are also available for user required number of channels

• Standard screw terminals for easy and reliable connections

• Transient suppression on inputs and outputs

• Wide selection of input and output options (tell us what your needs are)

• Wide range of auxiliary PS options

• Inputs, outputs, and auxiliary power supply are galvanically isolated

• DC voltage, or DC current outputs available (enquire)

• Backup to provide you support for design, applications information, installation, maintenance

Page 3: Newsletter_201603 Erica

SURETECH Instruments Newsletter March 2016

3

Transducer Specifications: (enquire for different configurations)

TYPE SYSTEM MODEL INPUTS OUTPUTS AUX PS ACCURACY

CURRENT Single phase 45-65Hz

TRD/1Ph/I 0-5 A AC 0-10A AC 0-20A AC

0-5V DC 0-10V DC 0-20 mA 4-20 mA

90-260 VAC Class 0.5

CURRENT 3 phase 45-65Hz (4 channel also avail)

TRD/3Ph/I 0-5 A AC 0-10A AC 0-20A AC

0-5V DC 0-10V DC 0-20 mA 4-20 mA

90-260VAC Class 0.5

VOLTAGE Single phase 45-65Hz

TRD/1Ph/V 0-110VAC 0-220VAC 0-1kV AC

0-5V DC 0-10V DC 0-20 mA 4-20 mA

90-260VAC Class 0.5

VOLTAGE 3 phase 45-65Hz

TRD/3Ph/V 0-110VAC 0-220VAC 0-1kV AC

0-5V DC 0-10V DC 0-20 mA 4-20 mA

90-260VAC Class 0.5

KVA 3 phase 4 wire

TRD/3Ph/V 0-110VAC 0-220VAC 0-1kV AC

0-5V DC 0-10V DC 0-20 mA 4-20 mA

90-260VAC Class 0.5

If you would like to see ALL the SURETECH Instruments, then our latest PRODUCT CATALOGUE is available on our website. Click here to access it or email Erica at [email protected] and she will send you a copy.

Page 4: Newsletter_201603 Erica

SURETECH Instruments Newsletter March 2016

4

SURE Engineering contact details: Contact Erica to enquire for the discount pricing or to place an order. Tel: 021 – 701 8529 Email: [email protected] Website: http://www.suretech.co.za Copyright © 2016 SURE Engineering All rights reserved.

Our mailing address is: SURE Engineering P.O. Box 63 Steenberg 7947 Cape Town