New ProductsFeaturing• WarmCair condensing warm air heaters
• QuanTec condensing boilers
www.johnsonandstarley.co.uk
HEATING
VENTILATION
RENEWABLES
2013 WINNERof the
Most Innovative Product
Building on our position as Market leaders in the Warm Air Heating Industry and using
the latest proven cutting edge technology, the WarmCair range of Condensing Warm
Air Heaters have been designed to offer exceptional reliability, unrivalled efficiency and
warmth combined with low carbon emissions and low operating noise levels. Patent
applications are in place for Europe the USA and Canada.
Suitable for upgrades and new build the WarmCair range can replace any existing Warm
Air Heater. Having a thermal efficiency of up to 98%, indications from our field trial have
shown savings in gas consumption of <28%. These savings are dependent upon the
usage, lifestyle, property size, insulation values and fuel costs.
Without doubt our most innovative Warm Air Heater development and with the range
going up to 46kW units for the first time, they will be capable of meeting commercial
Heating requirements in schools, retail outlets, sports halls and comunity centres etc.
Warming to a new generation of domestic heating systems
2 www.johnsonandstarley.co.uk
space heating
Downflow Upflow Combined downflow & DHW
Page number 4 10 14
Type Air Heater Air heater Air and water heater
Application Warm air heating Warm air heating Warm air heating & DHW
Models 5 4 3
Mounting Floor Floor Floor
Output range 10-46kW 16-46kW 16-20kW
Control option Modulating Modulating Modulating
Providing a new generation of economic and energy-efficient domestic heating systems
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 3
Warm air heating solutions
WarmCair product selector
Features
How the system works
Electronic filtration
Up to 98% Thermal Efficiency
Low carbon & NOx emissions
Enhanced electronic control
Fully modulating
Electronic air cleaner option
Room Sealed
Available range 10kW to 46kW
Summer air circulation facility
Available either upflow or downflow
DW combined downflow with integral DHW
Patent pending for EU North America and Canada
Polluted airenters unit
Wire meshpre-filter (earthed)
High voltage screen
Wire mesh filter (earthed)
Polluted air enters unit Polarized glass fibre pads
CLE
AN
ER
AIR
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
The ‘C’ Series range of heaters use the latest technologies available resulting in reduced running cost, noise and emissions.The sophisticated controls that enable the precise amount of heat output to match the demand. Being a condensing appliance it uses less energy to produce the required heat output as it uses more of the energy input when compared to a similar sized non-condensing heater.
The additional heat energy is produced by passing the exhaust flue gases through a secondary heat exchanger where the heat is transferred into the air stream. In this way latent heat, which would otherwise escape and be lost to atmosphere, is substantially recovered and utilised in the heat delivery process.
The option of Cleanflow electronic filtration: will provide your system with the added benefit of filtered air within the home. With the heating unit running on full demand the air in the house will pass over the heater six times per hour. At every pass the air will be filtered and 95% of airborne pollutants down to 1 micron can be removed. Particles such as pollen, house dust and cigarette smoke will be eliminated.
4 www.johnsonandstarley.co.uk
WarmCair ‘C’ series
C26D Internal view
Controller
Time control A & B Changedisplay up and down
LED display
D & E Test mode up and down minimum to maximum
Summer aircirculation
CTest mode
Reset
1. Flue test point
2. MMI Control panel with time control
3. Electrical Terminal Connector Board
4. Sliding flue connector
5. Combustion air fan assembly
6. Exhaust flue drain elbow
7. Gas valve/venturi with burner arm
8. Integral condensate pump
9. Duct temperature sensor
10. Gas cock
11. ESYS PCB
12. Flue collector box
13. EC Air circulation fan
14. LED display
15. Air filter
WarmCair Downflow
1
2
3
4
5
6
7
8
15
14
13
12
11
10
9
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 5
Warm air heating solutions
- downflow models
front front
6 www.johnsonandstarley.co.uk
WarmCair ‘C’ seriesR
esis
tanc
e E
xter
nal t
o H
eate
r
Fan Performance
0 100 200 300 400 500 600 700 800 900m³/h
70
60
50
40
30
20
10
0
FIGURE 11. FAN PERFORMANCE GRAPH C10D
PASCALS
FAN MODULATION RANGE
FIGURE 11. FAN PERFORMANCE GRAPH C16D & D16U
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
0 100 200 300 400 500 600 700 800 900 1000 1100m³/h
70
60
50
40
30
20
10
0
PASCALS
FAN MODULATION RANGE
Specifications
WarmCair C16D
Air heater: WarmCair C16D
Max output: 14.08kW
Weight: 62kg
NOx class: 5
Specifications
WarmCair C10D
Air heater: WarmCair C10D
Max output: 8.8kW
Weight: 48kg
NOx class: 5
Fan performance Fan performance
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
300
1200
550
244
267
32 46
72123
1340
146
171
52
102
133
45735
35
132
56
185
mCaire C10War D
400
1200
665
150
129
1340
344
381
72
80
185
104
57
113
272
15
9852225
mCaire C16War D
Front view Front viewSide view Side view
Plan viewPlan view
Base viewBase view
61
105185
113
1547
2
20672
45 23
141
1399
158
148
1257
600
64
425
544
740
front
front
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 7
Warm air heating solutions
Specifications
WarmCair C36D
Air heater: WarmCair C36D
Max Output: 31.86kW
Weight: 96kg
NOx Class: 5
Specifications
WarmCair C26D
Air heater: WarmCair C26D
Max Output: 22.88kW
Weight: 68kg
NOx Class: 5
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
FIGURE 11. FAN PERFORMANCE GRAPH C26D & D26U
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
1000 1200 1400 1600 1800 2000 2100 2400 2600 2800m³/h
175
150
125
100
75
50
25
0
PASCALS
FAN MODULATION RANGE
FIGURE 11. FAN PERFORMANCE GRAPH C36D & D36U
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
PASCALS
175
150
125
100
75
50
25
01000 1200 1400 1600 1800 2000 2100 2400 2600 2800m³/h
FAN MODULATION RANGE
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
IN Wg
Fan performance Fan performance
186
106
58
61 565 43
39
295
146
1339
666
129
151
1200
485
430
381
Front view Front viewSide view Side view
Plan viewPlan view
Base view Base view
800
- downflow models
front
8 www.johnsonandstarley.co.uk
WarmCair ‘C’ series
Specifications
WarmCair C46D
Air heater: WarmCair C46D
Max output: 40.48kW
Weight: 96kg
NOx class: 5
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
FIGURE 11. FAN PERFORMANCE GRAPH C46D & D46U
1000 1200 1400 1600 1800 2000 2100 2400 2600 2800 3000m³/h
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
175
150
125
100
75
50
25
0
PASCALS
FAN MODULATION RANGE
Fan performance
61
105185
113
1547
2
20672
45 23
141
1399
158
148
1257
600
64
425
544
740
Front view Side view
Plan view Base view
The highly versatile range of downflow warm air heaters has been designed with the user and installer in mind for a comfortable and quiet life.
800
800
space heating
9
Features
How the system works
Electronic filtration
Up to 98% Thermal Efficiency
Low carbon & NOx emissions
Enhanced electronic control
Fully modulating
Electronic air cleaner option
Room Sealed
Available range 16kW to 46kW
Summer air circulation facility
Available either upflow or downflow
Patent pending for EU North and South America
Polluted airenters unit
Wire meshpre-filter (earthed)
High voltage screen
Wire mesh filter (earthed)
Polluted air enters unit Polarized glass fibre pads
CLE
AN
ER
AIR
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
WarmCair upflow warm air heaters designed to meet the standards expected of a central heating system for the millennium.The sophisticated controls that enable the precise amount of heat output to match the demand. Being a condensing appliance it uses less energy to produce the required heat output as it uses more of the energy input when compared to a similar sized non-condensing heater.
The additional heat energy is produced by passing the exhaust flue gases through a secondary heat exchanger where the heat is transferred into the air stream. In this way latent heat, which would otherwise escape and be lost to atmosphere, is substantially recovered and utilised in the heat delivery process.
The option of Cleanflow electronic filtration: will provide your system with the added benefit of filtered air within the home. With the heating unit running on full demand the air in the house will pass over the heater six times per hour. At every pass the air will be filtered and 95% of airborne pollutants down to 1 micron can be removed. Particles such as pollen, house dust and cigarette smoke will be eliminated.
- upflow models
10 www.johnsonandstarley.co.uk
WarmCair ‘C’ series
1. Combustion measuring point
2. MMI Control panel with time control
3. Gas valve/venturi with burner arm
4. Sliding flue connector
5. Exhaust flue drain elbow
6. EC Air circulation fan
7. Condensate trap
8. Integral condensate pump
9. Air pressure switch
10. Air flter
11. Electrical Terminal Connector Board
12. Combustion air fan assembly
13. Flue collector box
14. Gas cock
15. ESYS PCB
16. LED display
15. Air filter
17. Duct temperature sensor
1
2
4
3
5
6
7
8
9
17
16
15
13
14
12
11
10
Controller
Time control A & B Changedisplay up and down
LED display
D & E Test mode up and down minimum to maximum
Summer aircirculation
CTest mode
Reset
C26U Internal view
WarmCair upflow
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 11
Warm air heating solutions
12 www.johnsonandstarley.co.uk
WarmCair ‘C’ series
Specifications
WarmCair C26U
Air heater: WarmCair C26U
Max Output: 22.88kW
Weight: 68kg
NOx Class: 5
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
FIGURE 11. FAN PERFORMANCE GRAPH C26D & D26U
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
1000 1200 1400 1600 1800 2000 2100 2400 2600 2800m³/h
175
150
125
100
75
50
25
0
PASCALS
FAN MODULATION RANGE
Fan performance
1200
485
1339
665
405
126
197
120
89 513 65
53438
5
53
123
133
93
445
418
3333
29
190
74 56 5050
Front view Side view
Plan view Base view
Specifications
WarmCair C16U
Air heater: WarmCair C16U
Max output: 14.08kW
Weight: 65kg
NOx class: 5
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
FIGURE 11. FAN PERFORMANCE GRAPH C16D & D16U
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
0 100 200 300 400 500 600 700 800 900 1000 1100m³/h
70
60
50
40
30
20
10
0
PASCALS
FAN MODULATION RANGE
Fan performance
1200
400
1339
64
665
405
197
120
125
88 513
120
65
535
400
133
122
54
190 444 29
3333
433
Front view Side view
Plan view Base view
- upflow models
front
front
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 13
Warm air heating solutions
Specifications
WarmCair C46U
Air heater: WarmCair C46U
Max output: 40.48kW
Weight: 96kg
NOx class: 5
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
FIGURE 11. FAN PERFORMANCE GRAPH C46D & D46U
1000 1200 1400 1600 1800 2000 2100 2400 2600 2800 3000m³/h
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
175
150
125
100
75
50
25
0
PASCALS
FAN MODULATION RANGE
Fan performance
Front view Side view
Plan view Base view
Specifications
WarmCair C36U
Air heater: WarmCair C36U
Max Output: 31.86kW
Weight: 96kg
NOx Class: 5
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
FIGURE 11. FAN PERFORMANCE GRAPH C36D & D36U
Res
ista
nce
Ext
erna
l to
Hea
ter
Fan Performance
PASCALS
175
150
125
100
75
50
25
01000 1200 1400 1600 1800 2000 2100 2400 2600 2800m³/h
FAN MODULATION RANGE
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
IN Wg
Fan performance
600
1254
1399
142
740
316
97 557 9389
64
500
648128
55
533
509 34198
600
1254
1399
142
740
316
97 557 9389
64
500
648128
55
533
509 34198
Front view Side view
Plan view Base view
front
front
800 800
Features
Up to 98% Thermal Efficiency
Low carbon & NOx emissions
Enhanced electronic control
Fully modulating
Electronic air cleaner option
Room Sealed
Available range 10kW to 20kW
Summer air ventilation facility
Available as downflow only
DW models with integral DHW
WarmCair combined downflow hot water and warm air heater, designed to meet the standards expected of a central heating system for the millennium.A highly efficient condensing gas fired downflow forced convection air heater and water heater. Significant reductions in Carbon and NOx emissions are achieved. It has been designed with dual functionality to provide the user with warm air central heating and to provide domestic hot water. It is room sealed with a stainless steel heat exchanger, using a vertical or horizontal concentric flue system. For vented or unvented indirect DHW system applications only.
The option of Cleanflow electronic filtration: will provide your system with the added benefit of filtered air within the home. With the heating unit running on full demand the air in the house will pass over the heater six times per hour. At every pass the air will be filtered and 95% of airborne pollutants down to 1 micron can be removed. Particles such as pollen, house dust and cigarette smoke will be eliminated.
14 www.johnsonandstarley.co.uk
WarmCair ‘C’ series
How the system works
Electronic filtration Controller
Polluted airenters unit
Wire meshpre-filter (earthed)
High voltage screen
Wire mesh filter (earthed)
Time control
Central heatingtemperature + & -
LED display
Polluted air enters unit Polarized glass fibre padsInformation history
On/Offsummer/winter mode switch
Reset
CLE
AN
ER
AIR
combination space and water heating
1. Combustion measuring point
2. Cool door heat generator
3. Burner arm assembly
4. Flow & return sensors
5. Gas valve
6. Condensate trap
7. Gas cock
8. Pump assembly
9. Water to air Heat exchanger
10. Return water temperature sensor
11. Drain cock
12. Condensate pump
13. Air cirulation fan
14. Air filter
15. PCB interface
16. PCBassembly
17. Combustion air fan
18. Air pressure switch (optional)
19. Flue sensor
20. Control panel
1
2
5
3
4
6
7
8
19
18
1615
17
14
13
12
10
9
11
C16DW Internal view
WarmCair combined downflow & DHW
9
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 15
Warm air heating solutions
1350
44514
80
550
77
722
90
181
194
335
515
341
355
4444
123 51146
105210 49
376
18301
222
57
286
51
1355
621
1480
316 90
550130
365 54
318
283
30
90
202
143
286
301
1
249
5856
824
8
158
6554
37
137
723
8155
1
194
181
335
16 www.johnsonandstarley.co.uk
WarmCair ‘C’ series
Specifications
WarmCair C16DW
Fan performance
Specifications
WarmCair C10DW
Air heater: WarmCair C10DW
Warm air heating output: 10KW
Weight: 66kg
NOx class: 5
DHW efficiency: 89.56%
Air heater: WarmCair C16DW
Warm air heating output: 16KW
Weight: 76.5kg
NOx class: 5
DHW efficiency: 89.6%
0 200 400 600 800 1000 1200 1400m³/h
140
120
100
80
60
40
20
0
RESI
STAN
CE E
XTER
NAL
TO H
EATE
R
FAN PERFORMANCE
Fan performance
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
0 200 400 600 800 1000 1200 1400m³/h
140
120
100
80
60
40
20
0
RESI
STAN
CE E
XTER
NAL
TO H
EATE
R
FAN PERFORMANCE
Front viewFront view Side viewSide view
Plan viewPlan view Base viewBase view
front
front
- combined downflow air heater & DHW
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 17
Warm air heating solutions
Specifications
WarmCair C20DW
Fan performance
Air heater: WarmCair C20DW
Warm air heating output: 20KW
Weight: 82.5kg
NOx class: 5
DHW efficiency: 89.6%
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
The highly versatile range of Combined warm air heaters have been designed with the user and installer in mind.
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200m³/h
180
160
140
120
100
80
60
40
20
0
RESI
STAN
CE E
XTER
NAL
TO H
EATE
R
FAN PERFORMANCE
Front view Side view
Plan view Base view
550
77
722
1350 14
80
90 537
628
181
194
335
123341
164
400
4448
90
146
198
251
327
49
302
286
222
3157
416
18
front
www.johnsonandstarley.co.uk
QuanTec boiler range
The QuanTec HR28C is the first thoroughbred combi boiler in the world with integral
PFGHR built into the primary heat exchanger of the boiler, delivering significant savings
in energy consumption, CO2 emissions and at an affordable price, giving a realistic
payback and a reduced environmental impact.
The full condense technology increases domestic hot water efficiency to levels not
reached before in any combi boiler. Energy savings of up to 26% over a typical water
heater are achieved.
Incorporating the PFGHR into the primary heat exchanger has resulted in raising
efficiency of the DHW to a weighted seasonal efficiency of 95.51% This has resulted
in the comparative hot water efficiencies currently being the highest listed on the SAP
Products Characteristics Database. (See www.boilers.org.uk)
Warming your home with the super efficient condensing boiler
space heating
19
HRPFG COMBI SYSTEM REGULARREGULAR COMPACT
Page number 22 23 24 25 26
TypePFGHR Combination
boilerCombination boiler System boiler Regular boiler Regular compact boiler
Application Space heating & DHW Space heating & DHW Space heating & DHW Space heating & DHW Space heating & DHW
Models 1 2 1 2 2
Mounting Wall Wall Wall Wall Wall
Output range 28kW 24 & 30kW 24kW 16 & 25kW 16 & 24kW
Control options Various Various Various Various Various
Providing a new generation of economic and super efficient domestic hot water & heating systems
QuanTec Product selector
QuanTec boiler range
Model
HR28CCombi with integral Passive Flue Gas Heat
Recovery (PFGHR) fitted as standard
30C Combi 24C
24C Combi 24C
24S System 24S
24R Regular 24R
16R Regular 16R
24Rk Reguar 24Rk kompact
16Rk Regular 16Rk kompact
Features
High efficiency
Low carbon & NOx emissions
Light weight
Enhanced electronic control
ERP compliant
Full Heat condense
The new reference of condensing technology
In addition to the isothermic advantages, the HR28C model gives DHW efficiency levels never reached before are achieved with the addition of pre-heating sanitary water function which results in the lowest possible flue gas temperatures and fuel consumption
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
ModelsUsing ‘Giannoni cool door’ technoloy
A robust and cost effective solution to heating and hot water delivery
www.johnsonandstarley.co.uk
QuanTec boiler range
Internal view
Giannoni isothermic stainless steel heat exchanger with cool door technology
Cool door technology enables NOx levels to fall below 40mg/kWH
Giannoni full condense stainless steel heat exchanger with inbuilt PFGHR (HR28C model)
Full condense technology increases energy savings of 26% over the most efficient hot water heater on the market (HR28C model)
Lower flue temperatures reduce the plume to an almost invisible level (HR28C model)
PCB board and switches
Honeywell neXsys low power consumption electronic boiler control
Eliminates the need for separate boiler and user control
PFGHR cold water intake
Honeywell pre-mix gas control
Honeywell fan
Wilo group set
Rain catcher
Offset to centralise flue outlet
Giannoni cool door burnertechnology
Wilo pump adaptable for ERP compliance
Central heating temperature +
Central heating temperature -
On/Off, summer, winter modeswitch
Reset switch
DHW temperature +
DHW temperature -
Information history
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 21
Space heating solutions
Front view Side viewPlan view
Dimensions (mm)
1. Rain trap
2. Flue sensor
3. View port
4. Giannoni “cool door” heat exchanger
5. Ignition/detection electrode
6. Flow temperature sensor
7. Honeywell Combustion air fan
8. Condensate trap
9. Diverter valve
10 Gas valve
11. Control panel
12 Wilo Pump adaptable for ERP2015
13. CH water pressure sensor
14. Automatic air vent
15. Return thermistor sensor
16. DHW turbine sensor
17. DHW turbine sensor
18. Venturi/burner injector
19. Burner arm
20. Expansion vessel
21. Central offset flue outlet
1
2
5
3
4
6
7
10
11
129
8
19
20
21
1718
15
16
14
13
Internal view
QuanTec HR28C
Control panel
Model
HR28CCombi with integral Passice Flue Gas
Heat Recovery (PFGHR) fitted as standard
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
combi with integeral passive flue gas heat recovery
423 321
123
212
183
780
Base view
www.johnsonandstarley.co.uk
QuanTec boiler range
Front view Side viewPlan view
Dimensions (mm)
Control panel
1. Rain trap
2. Flue sensor
3. View port
4. Giannoni “cool door” heat exchanger
5. Ignition/detection electrode
6. Flow temperature sensor
7. Honeywell Combustion air fan
8. Condensate trap
9. Diverter valve
10 Gas valve
11. Control panel
12 Wilo Pump adaptable for ERP2015
13. CH water pressure sensor
14. Automatic air vent
15. Return thermistor sensor
16. Pressure relief valve
17. Venturi/burner injector
18. Burner arm
19. Expansion vessel
20. Central offset flue outlet
1
2
5
3
4
6
7
10
11
12
9
8
20
18
19
16
17
15
14
13
Internal view
QuanTec Combi 24C & 30C
Model
30C Combi 30C
24C Combi 24C
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
423 321
123
212
183
780
Base view
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 23
Space heating solutions
423 321
123
212
183
780
1. Rain trap
2. Flue sensor
3. View port
4. Giannoni cool door heat exchanger
5. Ignition/detection electrode
6. Flow temperature sensor
7. Honeywell Combustion air fan
8. Condensate trap
9. Gas valve
10. Control panel
11. Wilo Pump adaptable for ERP2015
12. CH water pressure sensor
13. Automatic air vent
14. Pressure relief valve
15. Venturi/Burner injector
16. Burner arm
17. Expansion vessel
18. Central offset flue outlet
1
2
5
3
4
6
7
9
10
8
18
15
16
17
14
13
12
11
Internal view
QuanTec System 24S
Dimensions (mm)
Front view Side viewPlan view
Base view
Model
24S System 24S
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
Control panel
www.johnsonandstarley.co.uk
QuanTec boiler range
423 321
123
212
183
780
1. Rain trap
2. Flue sensor
3. View port
4. Giannoni cool door heat exchanger
5. Ignition/detection electrode
6. Honeywell Combustion air fan
7. Condensate trap
8. Control panel
9 Gas valve
10. Venturi/Burner injector
11. Burner arm
12. Central offset flue outlet
1
4
2
3
5
7
9
6
8
12
10
11
Internal view
QuanTec Regular 16R & 24R
Dimensions (mm)
Front view Side viewPlan view
Base view
Model
24R Regular 24R
16R Regular 16R
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
Control panel
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 25
Space heating solutions
QuanTec Regular 16Rk & 24Rk kompact
Dimensions (mm)
Model
24Rk kompact Regular 24Rk kompact
16Rk kompact Regular 16Rk kompact
PART LPART LBUILDING REGULATIONS
FULLY COMPLIANT WITH
1. Flue sensor
2. View port
3. Giannoni cool door heat exchanger
4. Ignition/detection electrode
5. Honeywell Combustion air fan
6. Condensate trap
7. Control panel
8 Gas valve
9. Venturi/Burner injector
10. Burner arm
Internal features 1
2
3
4
7
5
6
8
8
9
www.johnsonandstarley.co.uk
QuanTec boiler range
370
646
303
119
184
129
184
Front view Side viewPlan view
Base view
HR28C Combi 30C Combi 24C System 24SRegular 16R/24R
Regular 16Rk/24Rk
Maximum weight lift kg 40 38 37 38 38
Gas supply mbar 2H - G20 - 20mbar
Gas connection mm 15mm copper
Gas Injector size 4.75 4.75 4.2 4.2 4.2 4
Domestic hot water flow and return mm 15mm copper -
Heating flow and return mm 22mm copper
Safety valve discharge mm 15mm copper - -
Flue terminal diameter mm 100mm (4”)
Average flue temperature-mass flow rate DHW °C - g/s 30°C 11g/s - - - - -
Average flue temperature-mass flow rate CH g/s 30°C 11g/s - - - - -
Condense drain mm 21.5mm plastic overflow pipe
Maximum heating system water content using fitted expansion vessel lts 73 73 73 73 - -
Electrical supply V ~ Hz 230V ~ 50Hz
Electrical rating W 100
External fuse rating A 3
Expansion vessel capacity lts 8 8 8 8 - -
Expansion vessel initial charge pressure bar 1.0 1.0 1.0 1.0 - -
Heating system minimum pressure bar 0.7 0.7 0.7 0.7 - -
DHW maximum inlet pressure bar 5 5 5 - - -
Minimum inlet pressure for maximum DHW flow rate bar - - - - - -
Maximum inlet pressure for DHW flow rate bar 10.0 - - - - -
Minimum inlet pressure for appliance to operate bar 0.2 0.2 0.2 0.2 - -
Maximum flow rate at 35°C l/m 12.3 12.3 10.1 - - -
Minimum domestic hot water flow rate l/m 2.0 2.0 2.0 - - -
Maximum flow temperature °C 60 60 60 - - -
DHW specific rate l/m 14.4 14.4 11.8 - - -
Water content CH lts 1.2 1.2 1.2 - - -
Water content DHW lts 1.0 1.0 1.0 - - -
Ball valves are fitted in water and gas connections
For larger systems use an additional expansion vessel
QuanTec technical data
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 27
Space heating solutions
WarmCair flue example
Flue information
Flue performance
Condensate
60/100mm diameter Horizontal and vertical concentric flues
60/100mm diameter flexible flue kit.
Balanced terminals.
Air/flue operates at very low temperatures.
No clearance needed between the air duct and adjacent services.
Vertical appliance adaptor is fitted as part of the air heater.
The condensing warm air heaters and boilers are certified with corresponding flue systems according to EU Directive on gas-fired devices.The maximum flue length permissible is 12m excluding the terminal.
The minimum flue length is 1.25m from the top of the appliance case to the top of the terminal.
Longer flues may be fitted, however the input to the appliance will reduce accordingly.
Elbows may be fitted within the system with a corresponding reduction in overall flue length.
If an extended horizontal flue is being used it must have a continuous fall back towards the appliance of 3˚ (52mm) per metre.
This ensures that condensate runs back into the appliance from the flue system for safe discharge via the condensate waste pipe.
28 www.johnsonandstarley.co.uk
Flue options
STANDARD HORIZONTAL FLUE KIT
OFFSET HORIZONTAL REAR FLUEEXTENDED HORIZONTAL REAR FLUE
Standard fluekit comprising of:
TurretHorizontal Terminal
Can be fitted to the left or the right.
Standard flue kit +
90˚ Elbow
Required ExtensionLength
Can be fitted to the left
or the right.
Vertical Appliance
Adaptor
Horizontal Terminal
90˚ Elbow
Required ExtensionLength
HORIZONTAL SIDE FLUE VERTICAL FLUE OFFSET VERTICAL FLUE
Can be fitted to the left or the right.
Standard Flue Kit comprising of
TurretHorizontal Terminal
Vertical Appliance Adaptor
Required Extension Lengths
Vertical Terminal
Can be fitted to the left or the right.
Turret
Vertical Terminal
90˚ Elbow
Required Extension Lengths
FRONT SIDE FLUE
Can be fitted to the left or the right.
Standard Flue Kit +90˚ Elbow
Required ExtensionLength
EXTENDED HORIZONTAL REAR FLUE
Plume terminalsEquivalent lengths
Quantec options
Guidelines for the maximum flue length are as follows.
1 x 90˚ Elbow + 12 metres straight
2 x 90˚ Elbow + 10 metres straight
3 x 90˚ Elbow + 8 metres straight
4 x 90˚ Elbow + 6 metres straight
When using 45˚ elbows
1 x 90˚ Elbow is equivalent to 2 x 45˚ Elbows
The flue duct outlet should be at least 600mm from the boundary line when facing it and at least 300mm from the boundary line when running parallel to it.
space heating
Sales/Spares 01604 707012 Replacement help line 01604 707011 29
Space heating solutions
ITEM DESCRIPTION QTY PARTS INCLUDED APPLICATION PART No.
1QUANTEC60/100 STANDARDHORIZONTAL FLUE KIT (white)
1
800mm Horizontal Terminal
Horizontal 1000-0020070Outside Wall Cover Plate
Inside Wall Cover Plate
Sealing rings
2 QUANTEC TURRET 1 Inside Wall Cover Plate Horizontal 1000-0020020
3 WARMCAIRHORIZONTAL TERMINAL (white)
1 Outside Wall Cover Plate
Horizontal 1000-00198301 Inside Wall Cover Plate
1 Outside Wall Cover Plate
4 VERTICAL APPLIANCE ADAPTOR (white) 1 Vertical adapter Vertical 1000-0018990
2 45˚ ELBOW WHITE 80mm Ø (white) 1 Elbow Horizontal + Vertical 1000-0018980
3 90˚ ELBOW WHITE 80mm Ø (white) 1 Elbow Horizontal + Vertical 1000-0018980
4 250mm STRAIGHT EXTENSION (white)
1 250mm Straight Extension
Horizontal + Vertical 1000-00189601 100mm Diameter Clamp
2 Screws
5 500mm STRAIGHT EXTENSION (white)
1 500mm Straight Extension
Horizontal + Vertical 1000-00189501 100mm Diameter Clamp
2 Screws
6 1000mm STRAIGHT EXTENSION (white)
1 1000mm Straight Extension
Horizontal + Vertical 1000-00189401 100mm Diameter Clamp
2 Screws
6 2000mm STRAIGHT EXTENSION (white)
1 2000mm Straight Extension
Horizontal + Vertical 1000-00232001 100mm Diameter Clamp
2 Screws
9 RIDGE TERMINAL (terracotta) 1 Condensing Concentric Ridge Terminal Vertical 1000-0021030
10 WALL FIXING BRACKET 100mm 1 Clamp for 100mm tube Horizontal + Vertical 1000-0020050
11 1140mm VERTICAL TERMINAL1 Vertical Terminal Assembly
Vertical 1000-00189301 Support Bracket
12 PLUME MANAGEMENT KIT60mm (black) 1 Horizontal 1000-0020730
13 1000mm EXTENSION FLUE 60mm (black) 1 1000mm Extension (60mm) Horizontal 1000-0020740
14 90˚ ELBOW BLACK 60mm Ø (black) 1 Elbow Horizontal 1000-0020680
15 45˚ ELBOW (BLACK) 60mm Ø (black) 2 Elbow Horizontal 1000-0020670
16 WALL FIXING BRACKET 60mm 1 Support Bracket Horizontal 1000-0020770
Flue part numbers
www.johnsonandstarley.co.uk
Flue options
space heating
31
Pub
licat
ion
No.
ZZ
1456
-3 M
ay 2
013
Johnson & Starley LtdRhosili Road, Brackmills,Northampton NN4 7LZ
[email protected]@johnsonandstarley.co.uk
Reception 01604 762881
Sales/Spares 01604 707012
Service/Warm air upgrade 01604 762881
Warm air upgrade 01604 707011
Johnson & Starley Dravo Division Industrial H&V Sales 01604 [email protected]
www.dravo.co.uk
In the interest of continuous development Johnson & Starley reserve the right to change specification without prior notice.