Off-the-Shelf, 20 Fr. Stent Graft System Endospan Endospan Endovascular Repair for the Aortic Arch Pre Procedure 6 Month Follow Up (Courtesy of Prof. Dr. Mario Lachat, M.D., University Hospital, Zurich, Switzerland) Endospan develops an innovative array of treatments for aneurysms and dissections throughout the aorta. Endospan has an EN ISO-13485:2012 approved quality system, accredited by DEKRA. Features & Potential Benefits Transforms a complex arch open repair into a TEVAR procedure Innovative design generates anatomical fixation @ BCA origin Endograft intended to exclude arch lesion while maintaining perfusion to descending aorta, supra-aortic arteries throughout procedure Increased intra-procedural and long-term stability attributable to unique structural design Intra-procedural stability facilitated by the through-and-through delivery system Minimizes manipulation in native arch NEXUS™ Clinical Experience The Nexus™ procedure is gaining clinical experience worldwide via a European Endospan-sponsored study and Compassionate Use cases. Various disease morphologies have been treated with the Nexus, including distal ascending, isolated, pseudoaneurysms, and residual dilations following open repair. CAUTION: The Nexus System is an investigational device. Limited by law to investigational use. It does not bear the CE mark. CAUTION: The Nexus System is an investigational device. Limited by law to investigational use. It does not bear the CE mark. Maskit St. 4, Herzlia Business Park, Herzlia, ISRAEL 46733 Tel: +972-97884490 | [email protected] | www.endospan.com MKT-BNEX-EN-R3-2016

new Nexus Brochure Jan16 F - cdn.exiteme.com...presentation and training Simulated Implantation at Endospan V i r t u a l r M o d el P l a s t e d E l o m e r M odel. Title: new Nexus

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: new Nexus Brochure Jan16 F - cdn.exiteme.com...presentation and training Simulated Implantation at Endospan V i r t u a l r M o d el P l a s t e d E l o m e r M odel. Title: new Nexus

O�- the- Shelf, 20 Fr. Stent Graft System

™Endospan

™Endospan

Endovascular Repairfor the Aortic ArchPre Procedure 6 Month Follow Up

(Courtesy of Prof. Dr. Mario Lachat, M.D., University Hospital, Zurich, Switzerland)

Endospan develops an innovative array of treatments foraneurysms and dissections throughout the aorta.Endospan has an EN ISO-13485:2012 approved quality system,accredited by DEKRA.

Features & Potential Bene�ts

Transforms a complex arch open repair into a TEVAR procedureInnovative design generates anatomical �xation @ BCA originEndograft intended to exclude arch lesion while maintaining perfusion to descending aorta, supra-aortic arteries throughout procedureIncreased intra-procedural and long-term stability attributable to unique structural designIntra-procedural stability facilitated by the through-and-through delivery systemMinimizes manipulation in native arch

NEXUS™ Clinical Experience

The Nexus™ procedure is gaining clinical experience worldwide via a European Endospan-sponsored study and Compassionate Use cases. Various disease morphologies have been treated with the Nexus, including distal ascending, isolated, pseudoaneurysms, and residual dilations following open repair.

CAUTION: The Nexus System is an investigational device.Limited by law to investigational use. It does not bear the CE mark.

CAUTION: The Nexus System is an investigational device.Limited by law to investigational use. It does not bear the CE mark.

Maskit St. 4, Herzlia Business Park, Herzlia, ISRAEL 46733Tel: +972-97884490 | [email protected] | www.endospan.com

MKT-BN

EX-EN-R3-2016

Page 2: new Nexus Brochure Jan16 F - cdn.exiteme.com...presentation and training Simulated Implantation at Endospan V i r t u a l r M o d el P l a s t e d E l o m e r M odel. Title: new Nexus

NEXUS™ Endovascular Repair for the Aortic Arch

O�-the-Shelf, 20 Fr.

Endospan’s NEXUS™ breathes new life into the treatment of aortic arch pathologies, transforming itinto a minimally invasive endovascular repair. The unique modular design with its 20Fr OD crossingpro�le, as �exible as modern technology allows, expands the range of eligible patients.

Lesion excluded while maintaining perfusion to descending aorta and supra-aortic branches.Revolutionary geometric design generates intra-procedural �xation and long-term stability, whilereducing arch manipulation.Expected to reduce complications and post-op recovery time.

The NEXUS™ Stent Graft System

Endovascular Aortic Arch repair presents a substantial challenge for even the most experienced physicians due to varying morphologies and unique anatomical structures. As a result, Endospan has developed a physician-training procedure, which includes the manufacturing of a patient speci�c elastomeric model, placed in a �ow simulator, which allows the physician to imitate the entire procedure, prior to the actual implantation. This tool allows the surgical team to better plan the procedure, identify speci�c challenges and key procedural landmarks.

Physician Training on a Patient Speci�c Elastomeric Model

Connections aremore secure,

providing reliableprevention of

detachment and/orType III endoleaks.

Off-the-shelfstent-graft

sizes

Off-the-shelfstent-graft

sizes

"M"shapedsegment

Elliptictantalum

ring

Fenestration[optional]

for an ePTFEcovered stent

Endospan has developed a set of 20Fr, hydrophilic, delivery systems with various curvature designs (straight, pre-curved, pre-shaped). The unique design aids in the passage through the complex anatomical structure of the Aortic arch.

NEXUS™ Unique Delivery System

Modeling process- From CT to Physician Training

Straight

Pre-shaped

Pre-curved

Candidate CT Screening- Initial evaluation of major anatomical parameters

Creation of exact elastomeric 3D reconstruction model of candidate's anatomy

Candidate Suitable Candidate Rejected

Pre-Op Simulated Implantation session at physician site:presentation and training

Simulated Implantation at Endospan

Virtual Model

Plaster Model

Elastomer Model