What is NFPA 70E? Originally developed at OSHA’s request, NFPA 70E Standards for Electrical Safety in the Workplace help companies and employees avoid workplace injuries and fatalies due to shock, electrocuon, arc flash, and arc blast. NFPA 70E focuses on praccal safeguards to protect personnel by reducing exposure to major electrical hazards. OSHA bases its electrical safety mandates – OSHA 1910 Subpart S and OSHA 1926 Subpart K – on the comprehensive informaon in this important standard.* 80% of electrical related accidents and fatalies involving Qualified Workers are caused by arc flash/arc blast. Arc Flash Hazard PPE Categories Arc Flash Hazard PPE Category Protecve Clothing Minimum Arc Rang of PPE (cal/cm 2 ) 1 1 layer: FR long sleeve shirt, FR pants, FR coverall, head protecon, leather protectors, foot protecon, eye protecon, voltage rated gloves 4 2 1 or 2 layers: T-shirt, FR long sleeve shirt, FR pants, FR coverall, face shield, voltage rated gloves, leather protectors, foot protecon, coon underwear, eye protecon, hearing protecon, head protecon 8 3 2 or 3 layers: T-shirt, FR long sleeve shirt, FR pants, FR coverall, flash hood, voltage rated gloves, leather protectors, foot protecon, coon underwear, eye protecon, hearing protecon, head protecon 25 4 3 or more layers: T-shirt, FR long sleeve shirt, FR pants, FR coverall, flash hood, voltage rated gloves, leather protectors, foot protecon, coon underwear, eye protecon, hearing protecon, head protecon 40 Source: ohsonline.com What you need to know about the NFPA 70E 2015 edion changes to Arc Rang to keep you protected. New ARC Flash Standards ARC RATING Transion from HRC Categories to PPE Levels “Hazard/Risk Category” will now be referred to as “PPE Category”. The new PPE Category is no longer task based. Eliminaon of HRC Level 0 HRC levels previously ranged from 0 to 4. Level 0 meant the worker was outside the arc flash boundary and no arc flash PPE was required. The new PPE Categories have eliminated level 0. However, non-melng clothing is required for tasks not included in PPE Categories 1 to 4. In the new NFPA 70E 2015 edion, the term AR or Arc Rated as it relates to Personal Protecve Equipment (PPE) was introduced to help differenate between AR and FR (Flame Resistant). The reason? ALL AR clothing is flame resistant, but not all FR clothing has an arc rang.

New ARC Flash Standards ARC RATING - Wholesale Safety …electrical safety mandates – OSHA 1910 Subpart S and OSHA 1926 Subpart K – on the comprehensive information in this important

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: New ARC Flash Standards ARC RATING - Wholesale Safety …electrical safety mandates – OSHA 1910 Subpart S and OSHA 1926 Subpart K – on the comprehensive information in this important

What is NFPA 70E?Originally developed at OSHA’s request, NFPA 70E Standards for Electrical Safety in the Workplace help companies and employees avoid workplace injuries and fatalities due to shock, electrocution, arc flash, and arc blast. NFPA 70E focuses on practical safeguards to protect personnel by reducing exposure to major electrical hazards. OSHA bases its electrical safety mandates – OSHA 1910 Subpart S and OSHA 1926 Subpart K – on the comprehensive information in this important standard.*

80% of electrical related accidents and fatalities involving Qualified Workers are caused by arc flash/arc blast.

Arc Flash Hazard PPE Categories Arc Flash Hazard

PPE Category

Protective Clothing

Minimum Arc Rating

of PPE (cal/cm2)

1 1 layer: FR long sleeve shirt, FR pants, FR coverall, head protection, leather protectors, foot protection, eye protection, voltage rated gloves 4

21 or 2 layers: T-shirt, FR long sleeve shirt, FR pants, FR coverall, face shield, voltage rated gloves, leather protectors, foot protection, cotton underwear, eye protection, hearing protection, head protection

8

32 or 3 layers: T-shirt, FR long sleeve shirt, FR pants, FR coverall, flash hood, voltage rated gloves, leather protectors, foot protection, cotton underwear, eye protection, hearing protection, head protection

25

43 or more layers: T-shirt, FR long sleeve shirt, FR pants, FR coverall, flash hood, voltage rated gloves, leather protectors, foot protection, cotton underwear, eye protection, hearing protection, head protection

40

Source: ohsonline.com

What you need to know about the NFPA 70E 2015 edition changes to Arc Rating to keep you protected.

New ARC Flash Standards ARC RATING

Transition from HRC Categories to PPE Levels“Hazard/Risk Category” will now be referred to as “PPE Category”. The new PPE Category is no longer task based.

Elimination of HRC Level 0HRC levels previously ranged from 0 to 4. Level 0 meant the worker was outside the arc flash boundary and no arc flash PPE was required. The new PPE Categories have eliminated level 0. However, non-melting clothing is required for tasks not included in PPE Categories 1 to 4.

In the new NFPA 70E 2015 edition, the term AR or Arc Rated as it relates to Personal Protective Equipment (PPE) was introduced to help differentiate between AR and FR (Flame Resistant). The reason? ALL AR clothing is flame resistant, but not all FR clothing has an arc rating.

Page 2: New ARC Flash Standards ARC RATING - Wholesale Safety …electrical safety mandates – OSHA 1910 Subpart S and OSHA 1926 Subpart K – on the comprehensive information in this important

Changes to Coverage RequirementsNon-Melting Clothing Required Under AR ClothingNon-AR garments worn underneath AR clothing must be made of all-natural, non-melting fibers.

Item #ARS

Shirts must be to be tucked into pants. Shirts and Coveralls must be fastened at the wrist and closed at the neck.

Electrical shock is the second leading

cause for lost time on the job (second only to burns) Source: BLS 2011 Report – Time Away from Work

Item #ARH

ARC Rated Balaclava RequirementsArc rated balaclava or hood now required where incident energy exposure is greater than 1.2 cal\cm2 to 12 cal\cm2 (previously 4 cal or greater). Arc rated full hood required at greater than 12 cal\cm2.

[email protected]©2015 Magid Glove & Safety Mfg. Co. LLC. All Rights Reserved. FLYNFPA Rev. 02/15. Sources: *nfpa.org; Drageland, C. (September 1, 2014). Say Goodbye to “Hazard Risk Categories”, Say Hello to “PPE Categories [Web blog post]. Retrieved February 18, 2015, from powerstudies.com/blog/say-goodbye-%E2%80%9Chazard-risk-categories%E2%80%9D-say-hello-%E2%80%9Cppe-categories%E2%80%9D;Hoagland, H. (May 1, 2014). Redefining PPE classifications for NFPA 70E: HRC 0 is Gone [Web blog post]. Retrieved February 18, 2015, from Electrical and Arc Flash safety. electricalarcflashsafety.com/redefining-ppe-classifications-for-nfpa-70e

Magid offers a full line of protective clothing including Spark Guard®, Weld Pro®, Magid A.R.C.™, Magid Ultralite™, AR Defense™ base layer, Magid AR/FR and Magid 2112.

The mission of the international nonprofit NFPA, established in 1896, is to reduce the worldwide burden of fire and other hazards on the quality of life by providing and advocating consensus codes and standards, research, training, and education. nfpa.org