Upload
vutu
View
225
Download
0
Embed Size (px)
Citation preview
1 20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Cytotoxic Isolators
Brand New – GloveFAST Integra
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Faster range of products for cytotoxic
handling
GloveFAST Integra CytoFAST Elite/Top GloveFAST Cyto
2
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Why a new Cytotoxic Isolator from Faster ?
Proven and constant growing toxicity of
anticancer drugs
Demand of safety for and from the operators
Demand from private and public clinics to
employ the correct equipment ( tenders )
Relative small number of players
Strong sales advantages
Lack of knowledge in the market/operators
New opportunities to exploit
3
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Target Markets • Hospitals
• Oncology units
• Big Oncology centers
• Research laboratories working with high potent compounds
• Pharma companies outsourcing production for hospitals
• Pharma companies
• Anytime the volumes of drugs to be handled are many
• Anytime the drugs are proven to be dangerous for the human beings
4
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Cytotoxic handling
Solutions provider
5
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Educational Programme • Plan to perform seminars within the year
• Meet customer needs of knowledge about
such topics
• Confirm your customers that you are a
solution provider and a partner they can
rely on
• Teach them about the technologies
available to guarantee safety within their
workplace
• Promote your Faster cytotoxic solutions …sell some Isolators!!
6
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013 7
GloveFAST Integra
Useful
Dimensions
Overall
Dimensions
Integra 09 850mm 1350mm
Integra 12 1155mm 1655mm
Integra 15 1460mm 1960mm
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Air Flow pattern
8
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Technical Specifications
Construction Full body made in epoxy painted steel painted with
antimicrobial coating – internal surfaces made in
stainless steel ( AISI 304 + AISI 316 )
Filtration n.04 certified low pressure drop absolute filters H14
ULPA/HEPA conforming to CEN EN 1822
Screens Frontal glass is made in 8mm stratified safety glass
– side glasses made in 6mm safety glass
Interlock system Transfer hatch doors electro-magnetical interlocked
Tightness of the body carcass Class 3 according to ISO 10648-2 and ISO 14644-7
Air flow speed 0,40 m/s operating LAF – 0,25 m/s half speed
reduction
9
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Technical Specifications
Operating pressure - 75 Pa
Gloves and sleeves Flanges made in PE material with O-Ring system –
Gloves made in neoprene and sleeves in textile
material
Dimensions Available in 3 bench sizes ( 850 / 1155 / 1460 mm )
Compliances
• Filtration: H14 EN 1822 – ULPA IEST-RP-CC00
1.3/007/034.1
• Air Cleanliness: ISO 3 according to ISO 14644- 1
• Isolators: ISO 10648 1-2 // ISO 14644-7 // ISO
13408 // Annex 1 to GMP
• Electrical safety: IEC 61010-1 – UL 61010-1
10
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Documentations
Brochure:
Technical Specifications: Available GloveFAST Integra
Technical Drawing: Available
11
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
GloveFAST Cyto – GloveFAST Integra
differences Target customer- Integra unit is conceived to be proposed to hospitals as
an alternative to standard open front cytotoxic cabinets. GF Cyto can be
offered to pharma industries and/or research institutes and whenever the
volume of handled drug is considerable
Confort – GF Cyto offers much confort and better ergonomy thanks to
double pass box and bigger working surface
Classification – GF Cyto is an isolator system classified in Class 2 ( hourly
leak rate <2,5*10-2 ) according to ISO standard 10644-8-2 while GF Integra is
classified in Class 3 ( hourly leak rate <10-3 )
12
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Customizations – GF Cyto can be equipped with more customizations
such as number of electrical sockets, LCD screen positioning
Filtration – GF Cyto has higher filtration surface ( 7 HEPA filters ) in
comparison to GF Integra ( 4 HEPA filters )
Certification – GF Cyto is certified by TUV in relation to the hourly leak
rate as a «closed safety system ). The leakage of GloveFAST Integra is not
tested and the unit is classified under manufacturer declaration
GloveFAST Cyto – GloveFAST Integra
differences
13
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013 14
GloveFAST Cyto – GloveFAST Integra
TUV Certification
Faster Isolator line has been tested and certified by TUV in relation
to the hourly leakage rate pressure test according to :
• ISO 14644-7
• ISO 10648-2
This is a strong sales tool as Isolators equipment can be classified
only by the real tightness of the body carcass and we have tested the
unit by TUV indipendent body. ( TUV certification )
TUV Test
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013 15
Approaching the customer to: 1) get customer’s attention 2) get
informations 3) find who is the decision maker 4) scout for opportunities
« I see you handle cytotoxic compounds into open front cabinets. I need
your help to understand how you manage to guarantee the safety in your
lab. I know these cytotoxic drugs can be really harmful for the persons. I
visit many colleagues of yours in many institutes and I always find
different situations. Please, tell me how you provide safety for your
people here, have you internal protocols or something ?»
« Well, actually we do have internal protocols which indicate the
behaviours in case of contaminations…bla bla bla…bla bla bla bla »
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013 16
« Great, I see that the safety for the operators is something you take care
of in this lab. The health of your people is important, isn’t it ? Well,
actually having internal protocols is the first step to guarantee the safety
for your own team. Each center of excellence which i have the pleasure
to serve has well structured protocols further to the most updated
equipment. The right equipment are also important in your activities as
are devices designed to provide the safety for your people. I mean, if I
would be the guy to handle all day long cancerogenic drugs i’d like to
work it in safe conditions. Do you agree with me ? Take driving as an
example, driving is a dangerous activity itself but we drive more
confident knowing that there are ABS,EDS, traction control and many
other tools which works for our safety. »
« Yes, Yes. At this stage, you got to have won a double YES. If not,
start again from the beginning. It is important the customer itself
confirm that the safety for the team is important and the team need to
work with the correct machines. »
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013 17
Your results today:
You have introduced in professional way yourself and your company,
You have stimulated correctly the interest of your customer,
You have sowed the seeds of a future business,
You won the partecipation of the customer to a company event,
You know who is the decision maker in that building
Multiply today activity for all of yours potential customer of isolators and
the success will come
20th Faster Distributor Meeting -
Cornaredo 13-14 June 2013
Thank you for your attention
18