Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
jnes& &Professional Regulation VeEXE&tfFffiSXl
nesgfc.essional
p^AnnnwalMenu >Prnrl,,rf or AppWQn Search >&>P»Mft>" U« >App.ication Detail
Product ApprovalUSER: Public User
FL#
Application TypeCode Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance RepresentativeAddress/Phone/Email
Category
Subcategory
Compliance Method
FL10674-R12
Revision
2014
Approved*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified bythe POC and/or the Commission if necessary.
Owens Corning
One Owens Corning ParkwayToledo, OH 43659(740)[email protected]
Greg [email protected]
Mel Sancrant
1 Owens Corning PKWYToledo, OH 43659(419) [email protected]
V-
Roofing
Asphalt Shingles
Evaluation Report from a Florida Registered Architect or a Licensed FloridaProfessional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert 3.M. NieminenEvaluation Report
Florida License
Quality Assurance EntityQuality Assurance Contract Expiration DateValidated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence ofProduct StandardsCertified By
Sections from the Code
PE-59166
ULLLC
08/20/2017
John W. Knezevich, PE
3 Validation Checklist - Hardcopy Received
FI10674 R.12.-CQJL2flIfi n1 r°I Nigmingp.pdf
Standard
ASTM D3161
ASTM D3462
ASTM D7158
Year
2009
2009
2008
ProductApproval MethodMethod 1 Option D
Date Submitted
Date Validated
Date Pending FBC ApprovalDate Approved
summary of Products
FL#Model, Number or Name
04/18/2016
04/19/201604/20/2016
06/08/2016
10674.1 Owens Corning Asphalt RoofingShingles and Starters
3-tab, 4-tab, 5-tab, laminated, starter and hip &ridge shingles
Limits of UseApproved for use in HVHZ: NoApproved for use outside HVHZ: YesImpact Resistant: N/ADesign Pressure: N/AOther: Refer to ER, Section 5.
Installation Instructionsf^df,?* R1.2 T* ?nifi M FINAI FR oc ASPHALT
cM|̂ rHf=S FM0674-Rl2.pdfVerified By: Robert J. M. Nieminen PE - 59166Created by Independent Third Party: YesEvaluation ReportsF| 1f1fi74 Rl? *F ?m6 04 FINAL ER OC ASPHALT
SHTNKIFS FL10674-RX2,pd,fCreated by Independent Third Party: Yes
lBackl iNextl
Sma^j..; -^ M^h Mnnm. str^r Tallahassee Fl 32399 Phnnr; fif?tH87-1824
The State of Florid, is an AA/EEO employer, rnpyrinht 7007^011 *„tf of Plond^. :: Edy^^m.Qt :: ^MtV St^ment :: P*UP(I Stl,^Under Honda .aw, emai. addresses are pub.ic records. If you do ^^Jg-™;^a^JS^pi^SS^e,eSo^^nS^^a^^^
Product Approval Accepts:
Bfffffl
X^~\
y
\i TRINITY M
ROOFING SYSTEMS EVALUATION:
l. Scope:
Product Category: Roofing
S2SU-* Owe^W f/halt Roof Shines, as produced by Owens Corning, have•demonstrated«1 ance wkh the following sections of the Florida Building Code and Florida Build.ng Code, Res,dent,a VolumeZ^CnW£« «-* *e following Standards. Compliance is subject to the Installation Recrementsand Limitations / Conditions of Use set forth herein.
2. Standards:
Section
1S07.2.5, R905.2.41507.2.7.1, R905.2.6.11507.2.7.1, R905.2.6.1
3. References:
Entity
ULLLC(CER9626)UL LLC (CER9626)UL LLC(TST9628)ULLLC(TST9628)ULLLC(TST9628)ULLLC(TST9628)UL LLC (TST9628)UL LLC (TST9628)Miami-Dade(CER1592)UL LLC (QUA9625)
Property
Physical PropertiesWind Resistance
Wind Resistance
Examination
Physicals &Wind ResistancePhysicals & Wind ResistancePhysical PropertiesWind Resistance
Physicals&Wind ResistanceWind Resistance
Physical PropertiesPhysical PropertiesFBC HVHZCompliance
Quality Control
Standard
ASTM D3462
ASTM D3161
ASTM D7158
Reference
File R2453, Vol. 320120516-R2453
06CA20263
11CA34308
4786093137
4786126532
Classification letter
Classification letter
Various NOAs
ServiceConfirmation, R2453
Year
2009
2009
2008
Date
02/15/2007
05/16/2012
04/18/2006
02/18/2012
02/01/201402/10/2014
02/13/2014
10/02/2015
Various
Exp. 08/20/2017
4. product Description:
4.1 AsphaltShingles:Classic* and Supreme* are fiberglass reinforced, 3-tab asphalt roof shingles.Berkshire* are fiberglass reinforced, 4-tab asphalt roof shingles.Devonshire"* are fiberglass reinforced, 5-tab asphalt roof shingles.Duration*, TruDefinition* Duration*, Duration* Premium Cool, TruDefinition* Duration Designer ColorCoTection, TruDefinition* Oakridge*, Oakridge* and WeatherGuard HP are fiberglass reinforced, lammatedasphalt roof shingles.Berkshire* Hip &Ridge Shingles, High Ridge, WeatherGuard* HP Hip &Ridge Shingles, ProEdge Hip &RidgeShingles and DuraRidge" Hip &Ridge Shingles are fiberglass reinforced, hip and ndge asphalt roof shingles.Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
5.
4.1.1
4.1.2
4.1.3
4.1.4
4.2
4.3
Limitations:
5l This is a building code evaluation. Neither Trinity|ERD nor Robert Nieminen, P.E. are, in any way, theDesigner of Record for any project on which this Evaluation Report, or previous versions thereof, .s/was usedfor permitting or design guidance unless retained specifically for that purpose.
5 2 This Evaluation Report isnotfor use in the HVHZ.5*3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLCCertificate ofAuthorization OS503
Evaluation Report O37940.O2.12-R7FL10674-R12
Revision 7:04/18/2016Page 2 of 8
5,4
5.4.1
5.4.2
5.4.3
5.4.4
5.5
\xj TRINlTYiERD
\A/ir,H Classification: 1^0777 1 and7^Z^-S shingles noted herein arejClawed "^^^^^XR905.2.6.1 to ASTM ~f-<^^^£^£*s««£6*» insta"atiOT re"UirementSuse in all wind zonesup to Va$d = 150 mph (Vult - iy« mpnj.to meet this wind rating. n.,--;*^
MOwensCorn,ngh^^^in accordance with FBC Tables 1507.2.7 1and ****** _ f Sect]on 6for instaHationacceptable for use in all wind zones up to Vasd =150 mph (Vult - 19* mpn,.rponirements to meet this wind rating.
the shingle manufacturer for data specific to each shingle.Refer to Owens Corning published information on wind resistance and installation «™tat,onsZproducts in the roof assembly shall have ,ua,ity assurance audit in accordance w,th the Ronda Bu„d,ngCodeand F.A.C. Rule 61G20-3.
INSTALLATION:
" SSf.au be acceptable to X^gJ^^JZZSZ.'"**Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections ou/.^ ,
S^phalt shingles shall comply with *-£££SS£**£T£ZZminimum four (4) nails per shingle in accordance with FBC Sections 150/.2exceptions: ...> Berkshire* shingles require minimum five (5) nails per shingle> WeatherGuard* HP shingles require minimum six (6) nails per shingle.> Devonshire- shingles require minimum six (6) nails per shintfe.> Starter Strip Shingle and Starter Strip Pius require mm.mum five (5) nails per strip.Refer to Owens Corning published information on wind resistance and installation limitations
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC1507.2.6 orR905.2.5. Staples are not permitted.
6.2.4 Where the roof s,ope exceeds 21 units vertical in 12 units horizontal, special methods of fasten.ng arerequired. See figures below for details.Minimum Nailing - Starter Strip Shingle and Starter Strip Plus:
6.1.1
6.2.1
6.2.5
toftott firstSttrWStripshingle with6" removed Starter Strip shinfito overhangs eaves and takes W-%"
Exterior Researchand Design,LLCCertificate ofAuthoritation 89SQ3
Wwtfwrlodc®
Ottp«dac
frit tootedr-3*trom««¥e
portioned along e«vt
Start* Strip ffcs ov«rh*ns* «*v«» «nd rtto* 1/4*-3M*
Evaluation Report O37940.02.12-R7FL10674-R12
Revision 7:04/18/2016Page 3 of 8
6.2.6 Minimum Nailing - Classic8 &Supreme:
Standard
NormalMantardor Ana paraHighWind dmtvjuun y
\TRINITY ERD
Metric Sized„„_., Mansard or Ar»a panm^Tatm* High Wind dsswnMy^^•rw.»*«non»a/« Area. W.„to.*»m»
vmfw««•«««-..*»..~— _______ I I r—s r: i~i Pv—rs—imTrrv^
S>ExposureExpo*icI6n
6.2.7 Minimum Nailing - Berkshire*:
Sttbrt striputt*<(*Meidw
Z
-i^m""1^ **~1^r* m*~^A
Standard Fastening Pattern
B 6/8* ExposureExposition
AsphaltrootingcementCtoooto d* ttehod* tslt&o
6-Nail Fastening Pattern
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, LLCCertificate of Authorization #9503
Evaluation Report O37940.02.12-R7FL10674-R12
Revision 7:04/18/2016Page 4 of 8
'• X
\XI
TRINITY ERD
6.21 Minimum Nailing -TruDefinition* Oakridge*, Oakridge*:
4Naflf>att*nEsquemacontdavoi
65/9" Exposure NalsBcposidto d*6S/9p*io. Cttves
B5~*Expwa»ExpMleUn ASMSpul?.
Nail Patt»mEsquema coit6 daws
1 (NailI Esqu
65/9"Exposuȣxposid6ttdt6Sr8pd9-
5 5/8" ExposutsExpost¬SWpdg.
Standard Fastening Pattern6-Nail Fastening Pattern
ExteriorResearchand Design,LLC.Certificate ofAuthorization #9503
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing - WeatherGuard* HP:
rwCTi
Sla^tWaVUwVfarftito—ntf
¥r-lariTTlaaiaJhriatUr--
Evaluation Report 037940.02.12-R7FL10674-R12
Revision 7:04/18/2016Page 6 of 8
6.3.5 Minimum Nailing - ProEdge Hip &Ridge Shingles:
StandardFasteningPattern
V
7 V
/
vJ TRINITY iERD
•11"-
•r \
6* Exposure
I-12'-
T
Sealant
6.3.6 Minimum Nailing - DuraRidge™ Hip &Ridge Shingles:Note: The drawings below pertain to minimum, as-tested attachment requirements. Refer to Owens Corningpublished installation instructions for their minimum requirements.
7. Labeling:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency notedherein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBCTable 1507.2.7.1 / R905.2.6.1.
8. Building Permit Requirements:As required by the Building Official or Authority Having jurisdiction in order to properly evaluate the installation ofthis product.
9. MANUFACTURING PLANTS:Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QArequirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC- QUA9625 ; (414) 248-6409; karen.buchmannOul.com
- END OF EVALUATION REPORT-
Exterior Research and Design, LLC.
Certificate of AuthorizationU9SQ3
Evaluation Report 037940.02.12-R7FL10674-R12
Revision 7:04/18/2016Page 8 of 3
business &Professional Regulationia Department?
sinessv(}Sessional
•Home Login IUser Registration Hot Topics Submit Surcharge Stats ft Facts Publications IFBC sScT^fS^"""' "u'nks""'SSPProduct ApprovalUSER: Public User
> Product pr Application search > Application List > Application Detail
FL#
Application TypeCode Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance RepresentativeAddress/Phone/Email
Category
Subcategory
Compliance Method
FL9777-R7
Revision
2014
Approved
Owens Corning
One Owens Corning ParkwayToledo, OH 43659(740)[email protected]
Greg Keeler
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed FloridaProfessional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. PriestEvaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration DateValidated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product StandardsCertified By
Sections from the Code
PE-74021
UL LLC
12/31/2020
Locke Bowden
3 Validation Checklist - Hardcopy Received
FL9777 R7 COI OCR14002.4A FBC 2014 Evaluation Report Wpar.hPrlnr-1,Non-HVHZ - final.pdf
Standard
ASTM D 1970
ASTM G 155
TAS 103
UL 1897
Yfijll
2009
2005
1995
2004
Date Submitted
Date Validated
Date Pending FBCApprovalDate Approved
Summary of Products
FL# Model, Number or Name
9777.1 Weatheriock G
Limits of Use
Approved for use in HVHZ: NoApproved for use outside HVHZ: YesImpact Resistant: N/ADesign Pressure: N/AOther: See evaluation report for limits of use.
9777.2 Weatheriock MAT
Limits of UseApproved for use in HVHZ: NoApproved for use outside HVHZ: YesImpact Resistant: N/ADesign Pressure: N/AOther: See evaluation report for limits of use.
9777.3 WeatherLock Metal
Limits of Use
Approved for use in HVHZ: NoApproved for use outside HVHZ: YesImpact Resistant: N/ADesign Pressure: N/AOther: See evaluation report for limits of use.
9777.4 Weatheriock Metal
Limits of Use
Approved for use in HVHZ: YesApproved for use outside HVHZ: NoImpact Resistant: N/ADesign Pressure: N/AOther: See evaluation report for limits of use.
04/19/2016
04/20/2016
04/21/2016
06/08/2016
Description
Weatherproof!ng Underlayment
Installation Instructions
FL9777 R7 H OCR14002.4A FBC 2014 Evaluation RenortWeatheriock Non-HVHZ • final.pdfVerified By: Zachary R. Priest 74021Created by Independent Third Party: Yes
Evaluation ReportsFU9777 R7 AE OCR14002.4A FBC 2014 Evaluation
Weatheriock Non-HVHZ - final.pdf
Created by Independent Third Party: Yes
Waterproofing Underlayment
Installation Instructions
FL9777 R7 II OCR14002.4A FBC 2014 Evaluation RenortWeatheriock Non-HVHZ - final.pdfVerified By: Zachary R. Priest 74021Created by Independent Third Party: Yes
Evaluation ReportsFL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Report
Weatheriock Non-HVHZ • final.prifCreated by Independent Third Party: Yes
Weatherproofmg Underlayment
Installation Instructions
FL9777 R7 II OCR14002.4A FBC 2014 Evaluation ReportWeatheriock Non-HVHZ - final.pdfVerified By: Zachary R. Priest PE-74021Created by Independent Third Party: Yes
Evaluation ReportsFL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Report
Weatheriock Non-HVHZ - final.pdf
Created by Independent Third Party: Yes
Weatherproof!ng Underlayment
Installation Instructions
FL9777 R7 II OCR14002.4B FBC 2014 Evaluation ReportWeatheriock Metal HVHZ - final.pdf
Verified By: Zachary R. Priest PE-74021Created by Independent Third Party: Yes
Evaluation ReportsFL9777 R7 AE OCR14002.4B FBC 2014 Evaluation Report
Weatheriock Metal HVHZ - final.pdfCreated by Independent Third Party: Yes
9777.5 WeatherLock Specialty Tile & Metal Weatherproofmg Underlayment
Limits of UseApproved for use in HVHZ: NoApproved for use outside HVHZ: YesImpact Resistant: N/ADesign Pressure: +0/-105Other: See evaluation report for limits of use.
Installation Instructions
FL9777 R7 II OCR14002.4A FBC 2014 Evaluation ReportWeatheriock Non-HVHZ - final.pdf
Verified By: Zachary R. Priest 74021Created by Independent Third Party: Yes
Evaluation ReportsFL9777 R7 AE OCR14002.4A FBC 2014 Evaluation Report
Weatheriock Non-HVHZ - final.pdf
Created by Independent Third Party: Yes
|Back| |Next|
Contact Us :: 1940 North Monroe Street. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not sendelectronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emailaddress If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do
not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you area licensee under Chaoter 455. F.S.. Dlease click here .
Technical Services, LLC
Certificate of Authorization No. 2982417520 Edinburgh Drive
Tampa, FL 33647(813)480-3421
EVALUATION REPORT Florida Building Code 5th Edition (2014)Manufacturer:
Issued ApriH9, 2016
Manufacturing Location:
Quality Assurance:
Scope
Category:Subcategory:Code Sections:
Properties:
References
OWENS CORNING ROOFING AND ASPHALT LLC1 Owens Corning ParkwayToledo, OH 43657(800) 438-7465www.owenscornina.com
Brentwood, NH
UL LLC (QUA9625)
RoofingUnderlayments1504.3.1,1507.2.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507.4.5, 1507.4 52 1507 531507.5.3.2, 1507.7.3, 1507.7.3.2Physical properties
EntityPRI ConstructionPR I ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI ConstructionPRI Construction
Materials
MaterialsMaterialsMaterials
Materials
Materials
MaterialsMaterials
Materials
MaterialsMaterialsMaterialsMaterials
TechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologiesTechnologies
(TST6049)(TST6049)(TST6049)(TST6049)(TST6049)(TST6049)(TST6049)(TST6049)(TST6049)(TST5878)(TST6049)(TST5878)(TST6049)
Report No.NEI-039-02-01NEI-042-02-01REV2NEI-045-02-01
NEI-045-02-01NEI-053-02-01NEI-053-02-01
NEI-093-02-02
OCF-213-02-01OCF-237-02-01OCF-252-02-01OCF-252-02-01OCF-253-02-02OCF-272-02-01
StandardASTMD 1970ASTM D 1970
TAS 103
ASTM G 155TAS 103ASTMG 155
ASTMD 1970ASTM D 1623UL1897
ASTM D 4798ASTMD 1970
ASTMD 1970TAS 103
Year2009
2009
1995
2005a
1995
2005a
20092009
2004
2001
2009
2009
1995
Product Description and Limits of Use
WeatherLock® G
WeatherLock® Mat
OCR14002.4A
WeatherLock® Gisan ASTM D1970 self-adhesive underlayment constructed from SBSmodified asphalt, a fiberglass mat reinforcement and surfaced with granules Theproduct is supplied in2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft.
WeatherLock® Gis permitted to be used with mechanically fastened asphalt shingleswood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on theroof deckshall be limited to a maximum 30 days.
WeatherLock® Mat is an ASTM D 1970 self-adhesive underlayment constructed fromSBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1-sq. rolls with nominal dimensions of3-ft x 33.3-ft and 2 sq. rolls with nominal dimensionsof 3-ft x 66.7-ft.
WeatherLock® Mat is permitted to be used with mechanically fastened asphalt shingleswood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on theroof deck shall be limited to a maximum 30days.
FL9777-R7 Page1of4This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEKTechnical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is validThis eva uation report does not express nor imply warranty, installation, recommended use. orother product attributes that are notspecifically addressed herein.
a CREEKTechnical Services, LLC
OWENS CORNING ROOFING AND ASPHALT LLCWeatherLock® Self-Sealing Ico&Water Barriers
WeatherLock® Metal
WeatherLock®Specialty Tile & Metal
Product Application
Min. Roof Slope:
Application:
Min. ApplicationTemperature:
OCR1-4002.4A
WeatherLock® Metal is an ASTM D1970 self-adhesive underlayment constructed fromSBS modified asphalt with a fiberglass mat reinforcement and plastic film surface Theproduct is supplied in 2.0sq. rolls with nominal dimensions of3-ft x66.7-ft.
WeatherLock® Metal is permitted to be used with mechanically fastened asphaltshingles, metal roof panels or shingles, wood shakes or shingles, and slate roofing asprescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90days.
WeatherLock® Specialty Tile &Metal is an ASTM D1970 self-adhesive underlaymentconstructed from SBS modified asphalt and surfaced with a non-woven polyester fabricTheproduct is supplied in 2.14sq. rolls with nominal dimensions of3-ft x 71.3-ft.
WeatherLock® Specialty Tile &Metal is permitted to be used with mechanically fastenedasphalt shingles, clay or concrete tile, metal roof panels or shingles, wood shakes orshingles, and slate roofing as prescribed in the FBC. WeatherLock® Specialty Tile &Metal is permitted to be used with adhered clay or concrete tile roofing using either 3M™2-Component Foam Roof Tile Adhesive AH-160 (3M Company) or TILE BOND™ RoofTileAdhesive (The Dow ChemicalCompany) 'to a maximum 90 days.
Exposure on the roof deck shall be limited
The maximum roof slope shall be 6:12 when used with clay or concrete tile installationswithout battens. Tile shall be stored on battens for roof slopes greater than 6:12 Tilesshall not be stacked greater 10 tiles per stack.
2:12 or in accordance in with FBC
Deck substrates shall be clean, dry, and free from any irregularities and debhs. Allfasteners in the deck shall bechecked for protrusion and corrected prior to underlaymentapplication. Prior to beginning installation, the underiayment shall be unrolled andallowed to relax for a minimum of 3-5 minutes.
The underlayment shall be installed with the release backer removed and pressed firmlyinto place toensure complete contact with the deck. The underlayment shall be installedwith the roll length parallel to the eave, starting at the eave, and with minimum 3" sidelaps and minimum 6" end laps staggered 6-ft. from preceding course. End laps forWeatherLock® Specialty Tile &Metal shall be primed with ASTM D41 primer or sealedwith asphalt roof cement a minimum of3-4 inches across thewidth ofthe lap.
It is permissible to nail the underlayment 18-inches on-center as needed (nails shall beinstalled perpendicular to deck with the nail heads flush to the top surface of theunderlayment). WeatherLock® Specialty Tile & Metal shall be back nailed wheninstalled on roof slopes greater than 3:12.
For valley applications, the roll shall be applied centered along the valley prior toinstalling the underlayment at the eave. For eave protection, the underlayment shouldextend to a point 24-inches inside the exterior wall.
The underlayment shall be installed over metal drip edge at the eave, and under the dripedge at the rake or valley pan when used as a valley liner. Alternately, it is permissibleto install the underlayment under the drip edge in accordance Section 1507.2.9.3.
40°F; Contact the manufacturer when installing at temperatures below the minimumapplication tempsrature.
FL9777-R7 Page 2 of 4This evaluation report is provided for State ofFlorida product approval under Rule 61G20-3. The manufacturer shall notify CREEKTechnical Services, LLC ofany product changes or quality assurancechanges throughout the duration for which this report is valid.This evaluation report does not express nor imply warranty, installation, recommended use. or otherproduct attributes that are notspecifically addressed herein.
CREEKTechnical Services, LLC
Wind Resistance
OWENS CORNING ROOFING AND ASPHALT LLCWeatherLock© Self-Sealing Ico &Water Barriers
The Maximum Design Pressures shown below were caloula.ed using a2:1 margin of safety per FBC Section 1504.9.Underlayment System Nn 1Roof Deck:
Underlayment:
Min. 15/32-inch CDX plywood attached to wood supports spaced amaximum 24" o.c.
SSS2S2?i St**, Ti'e &Meta' Sha" be applied in accordance withZT,*nl I installation instructions to the fastened deck and backnailed along theStm'TS 12g3' 1-1M-inch galvanized rin9 shank ^ng nails throughoptionally pnmed, 32ga. x 1-5/8-inch 0 tin caps spaced 12" o.c. The appHed
app'caTn601 r°"ed With ' minlmum ?5'b Steel r0,ler im^ediate.y following-105 psfMaximum Design
Pressure:
General Limitations
1)2)3)
9)
Thisevaluation report is not use in the HVHZ.Fire Classification is not within thescopeof this evaluationInstallation of the evaluated product shall comply with this report, the FBC, and the manufacturer's publishedSlSK^pd;SanCi6S 6XISt b"~" ^^ ™' ^ ™° '•S'XSSTh! ^ldeCkHShlbe, co,nstructed of cl°sely fitted plywood sheathing for new or existing constructionThe space under the deck area shall be properly ventilated in accordance with the FBC requirementAll side lap seams shall be installed to shed water from the deck equ'remenis.The underlayment may be used as described in other current FBC product approval documentsDesign wind load pressures shall be determined for components and cladding in accordance with FBC
™ad^t^ 3CC0rdanCe * FBC red—tS <° •— ** <"* wind10) saattss^a 9iven underlayment sha"meet or exceed the desi9n wind ioads11) RLer61GC20-3ted *" ^ ""* Sha" ^ manufactured under a^ality assurance program in compliance with
OCR14002.4A FL9777-R7 Page 3 of 4This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEKlecnnical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is validThis evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are notspecifically addressed herein.
CREEKTechnical Services, LLC
Compliance Statement
OWENS CORNING ROOFING AND ASPHALT LLCWeatherLock® Self-Sealing Ice&Water Barriers
^^^^^^Z^^^p^^^^^^^^^^^
$4Wz •
No 74C21
*
.* -
- "tJ \ IrzZ~?>\ STATE OF SMtS
'^/onaC^Certification of Independence
2016.04.19
^3—15:51:11
-04'00'
Zachary R. Priest, P.E.Florida Registration No. 74021Organization No. ANE9641
S*SSLCd06S n0t h3Ve' n°r "" "3CqUire' a**«* imereSt in an^ «»Wmanufacturing or disputing
tChfs7valLetiohniCal SerViCeS' LLC lS POt °VVned' °Perated' °r C°ntr0Hed by any COmpany manufacturing or distributing products under
££73*JSStaf d°eS n0t haV6, n°r Wi" aCqUire' afinanCial interest in any company manufacturing or distributing products
pr'oS R' PrieS'' P'E' d°eS n0t h3Ve' n°r Wi" *****' 3finandal interest in any 0,ner entily involved in the aPProval Process of the
End of Report
OCR14002.-1A FL9777-R7 Page 4 of 4This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEKTechnical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is validThis evaluation report does not express nor imply warranty, installation, recommended use, orother product attributes that are notspecifically addressed herein.