172
In 2013, Neodent celebrates 20 years in business. A beautiful path where each step taken, each product released and each detail enhanced materialized the values of excellence and innovation. The dental implants industry has grown, taken new directions, new technologies, and Neodent has tread along, following all steps and having a direct participation in that evolution process, always bringing out the best for the market and for customers. Looking at the 20 years that have gone by and seeing all the changes reassures us that a lot has already been done, yet the best is still ahead of us. 20 years of history in dental implants.

Neodent Product Catalogue - 2013

Embed Size (px)

DESCRIPTION

Neodent's Product Catalogue

Citation preview

Page 1: Neodent Product Catalogue - 2013

In 2013, Neodent celebrates 20 years in business. A beautiful

path where each step taken, each product released and each

detail enhanced materialized the values of excellence and

innovation.

The dental implants industry has grown, taken new directions,

new technologies, and Neodent has tread along, following

all steps and having a direct participation in that evolution

process, always bringing out the best for the market and for

customers.

Looking at the 20 years that have gone by and seeing all the

changes reassures us that a lot has already been done, yet

the best is still ahead of us.

20 years of historyin dental implants.

Page 2: Neodent Product Catalogue - 2013
Page 3: Neodent Product Catalogue - 2013

05

Technical Guidelines

Morse Taper Line

Ti External Hex Line

II Plus Internal Hex Line

WS Morse Taper Line

Zygomatic Line

Orthodontic Anchoring and Bone Grafting

Neodent Techniques

Neodent Kits

Surgical Instruments

07

18

50

78

96

106

112

122

144

156

Page 4: Neodent Product Catalogue - 2013

0606

Page 5: Neodent Product Catalogue - 2013

07

TechnicalGuidelines

07

Page 6: Neodent Product Catalogue - 2013

08

Through years of intense research and development of new technologies, NEODENT has reached the current

state-of-the-art in treating the surface of implants, the NeoPoros surface.

Based on an abrasive particle jet concept, followed by acid subtraction, the NeoPoros surface promotes,

through the use of controlled grain oxides, cavities in the implant surface, which are then made uniform by

the acid subtraction (SLA) technique.

The whole surfacing process is guaranteed by the automated control of time, speed, pressure and particle

size. Several ongoing scientific studies to ensure that the NeoPoros surface is in constant evolution, providing

you with greatly increased safety, are on go.

Constant evolution and guaranteed safety.

Scanning Electron

Microsope Imaging

of NeoPoros surface

in different regions of

Drive CM implant.

Surface

Page 7: Neodent Product Catalogue - 2013

09

Scanning Electron Microscope imaging of NeoPoros surface in

2000x and 3000x magnifications. Controlled roughness to ensure

pore size between 2.5 and 5.0μm through the whole implant surface.

Histological study of bone tissue

response in contact with Morse Taper

Implants with NeoPoros surface.

Research conducted at the Bauru

University Dentistry School in São Paulo,

as well as the Santa Catarina Federal

University, and the Chieti-Pescara

University in Italy.

Page 8: Neodent Product Catalogue - 2013

10

acqua

:: Hydrophilic Surface;

:: Greater surface energy;

:: Greater bone neoformation potential.

Page 9: Neodent Product Catalogue - 2013

11

Acqua surface is obtained through a physiochemical

process that provides an increase in the implant’s

superficial energy, clinically resulting in a spreading of

blood throughout the implant.

There is not only a reduction in the contact angle between liquid and surface and an increase in the titanium

superficial energy, but also an advancement of stages in the bone matrix formation process, when

compared to the NeoPoros surface**.

Contact angle > 30°

(Hydrophobic Surface)

NEOPOROS Contact angle < 5°

(Super-hydrophilic Surface)

ACQUA

NeoPoros

Acqua

* Research conducted at the Mechanical Projects Laboratory at the Uberlandia Federal University School of Mechanical Engineering.** Research conducted at the Dentistry Research Center – Biomechanics, Biomaterials and Cellular Biology at the Uberlandia Federal University Dentistry School and at the Bone & Mineralization Lab., University of North Carolina, Chapel Hill, USA.

Page 10: Neodent Product Catalogue - 2013

12

Implant packages have been overhauled.

Offering a concept that provides convenience and safety through all steps of the procedure,

from storage to capture and to the implant transportation to the surgical alveolus.

The new package eases identification of both the implant model as well as its diameter and

length, regardless of its storage position, streamlining office procedures.

Safety and convenience at arm’s reach.

New ImplantPackaging

Page 11: Neodent Product Catalogue - 2013

13

After breaking the sterility seal on the

Blister, hold the primary package

(crystal tube) with the non-dominant hand

and open the lid.

With the non-dominant hand, press both

sides of the stand, creating a gripping

effect in order to secure the implant.

Still pressing the stand, capture the implant

with the contra-angle handpiece, moving the

stand to find the perfect fit between

handpiece and implant.

The stand that holds the implant is removed

from the crystal tube along with the lid.

Keep pressing the stand and remove

the lid.

Transport the implant to the surgical alveolus

1

3

5

2

4

6

Page 12: Neodent Product Catalogue - 2013

14

IMPLANT INDICATION TABLE

Bone type I Bone type II Bone type III Bone type IV

According to Lekholm and Zarb bone classification (1985).

DriveCMTitamaxCM

TitamaxTi

AlvimTi

AlvimIIPlus

TitamaxIIPlus

TitamaxWSTitamaxWS

AlvimCM

Cortical

Cortical

Cortical

Medular

DriveTi

DriveCM

DriveTi

Page 13: Neodent Product Catalogue - 2013

15

CONNECTIONS AND TORQUES

0.9 1.2 1.6 Prosthetic Abutment

15N.cm

32N.cm

10N.cm

32N.cm

32N.cm32N.cm

32N.cm

32N.cm

20N.cm

20N.cm

20N.cm

20N.cm

32N.cm

32N.cm32N.cm

10N.cm20N.cm

20N.cm20N.cm20N.cm

20N.cm10N.cm

32N.cm

32N.cm

32N.cm

15N.cm15N.cm15N.cm

CM AbutmentCM and Exact Angled Mini Conical AbutmentCM Mini Conical Abutment and CM Micro AbutmentCM Universal PostCM Universal Post Passing ScrewCM and Exact Angled Universal PostCM and Exact Anatomic PostMini Ball AttachmentCylindersWS AbutmentWS Mini Conical AbutmentWS Universal PostConical Abutment (Ø 4.3) and Slim Fit (Ø 4.1)Conical Abutment (Ø 5.0)Mini Conical Abutment (Ø 3.3 and Ø 4.3)Mini Conical Slim Fit Abutment (Ø 5.0)Mini Conical Slim Fit Abutment (Ø 4.1)Mini Angled Conical Abutment (Ø 4.1)SF Universal Post, Customizable and AngledUCLA (Ø3.3; Ø4.1; Ø4.3; Ø5.0)Mini Ball AttachmentCylindersII Plus Conical Abut. and II Plus Mini Conical AbutmentII Plus Angled Conical AbutmentII Plus Universal and Angled postII Plus UCLAMini Ball AttachmentCylinders

MORSE TAPERCM

WS MORSE TAPERWS

EXTERNAL HEX

Ti

INTERNAL HEX

IIPlus

Visit the website for more information www.neodent.com.br/us

SELECTION OF PROSTHETIC ABUTMENTS ACCORDING TO ABUTMENT/IMPLANT INTERFACE

Multiple Prosthesis

Multiple Prosthesis

Multiple Prosthesis

Multiple Prosthesis

A . Over Intermediary B. Straight to Implant

Work Method

Single Prosthesis

Single Prosthesis

Single Prosthesis

Single Prosthesis

Pros

thes

is Ty

pe

1. ScrewRetained

2. Cemented

•Mini Conical Abutment•Angled Conical Abutment•Transepithelial Abutment•Micro Abutment

•Universal Post

•Conical Abutment•CM Abutment

•Anatomic Post•Universal Post•Customizable Post

•UCLA

•UCLA•Customizable Post

Page 14: Neodent Product Catalogue - 2013

16

APEX

PROS

THET

ICIN

TERF

ACE

IMPL

ANT

BODY

IMPLANT FEATURES

Page 15: Neodent Product Catalogue - 2013

17

Drive Titamax

CM HE II Plus WS

Alvim

AlvimCorticalDrive EX

Page 16: Neodent Product Catalogue - 2013

18

Implant with sealing interface to optimize the bacterial sealing

and peri-implant tissue health.

Morse Taper

18

Page 17: Neodent Product Catalogue - 2013

19

Streamlined instalation thatdoes not require assembler.

New CM driver

Exact lineabutments,specific forCM Index implants.

Morse Taperimplants are nowfitted withindexer.

:: Switching Platform Concept - Maintenance of cervical bone, greater width of soft tissue, with optimized aesthetics;

:: Now with Hex Prosthetic Index;:: Reduced GAP (sealing interface);:: Stable Anti-Rotation Tightening;:: High mechanical resistance;:: Single prosthetic interface, regardless of implant diameter;:: The proper angle of NeoDent’s Morse Taper allows for a threaded

cylindrical implant throughout, up to the cervical portion;:: Higher resistance when compared to external hex implants with

regular platform.

19

Abutment Indication Table

•CM Conical Abutment (single)•CM Mini Conical Abutment

(multiple)•CM Angled Conical Abutment

17° and 30°(multiple)•CM Micro Abutment

(multiple)

•CM Universal Angled Post17° and 30°•CM Universal PostPassing Screw•CM Universal Post (singlebody)•Titanium Anatomic Post

•CM Mini Ball Attachment •CM Micro Abutment•CM Mini Conical Abutment•CM Angled Conical Abutment17° and 30°•Cylinder and Distal Ext. Shaft

Passive Fitting Technique• Castable Cylinder Mini Conical Abut.•Titanium Cylinder MiniConical Abut.•Brass Cylinder Mini Conical Abut.

MORSE TAPER

3.5, 3.75, 4.0,4.3 and 5.0 mm

Screw RetainedProsthetics

CementedProsthetics Overdenture Protocol

Ø 2.5 mm

Ø Implant

MORSETAPER

Inne

r Thr

ead

Ø 1.

8

ImplantsCMMorse Taper

Page 18: Neodent Product Catalogue - 2013

20

The hex prosthetic index streamlines the implant Instalation process, reduces surgery times, increases insertion torque resistance and allows the dentistry professional to install the prosthesis already foreseeing the crown positioning in relation to the implant, allowing for increased safety, speed and versatility in clinical and lab procedures.

CM Implants withProsthetic Index

Implant Capture and TransportSpecific drivers to the implant’s hex prosthetic index, available for contra-angle, allow the

capture of implants directly from the package.

Replacing legacy assemblers with these Drivers ensures greater torque resistance, higher

speed and safety to the procedure.

Each implant Instalation must be initiated with the contra-angle Drivers (whether in contra-

angle or adapted to the digital driver for contra-angle connections – C.A.).

When the implant is thus secured, the contra-angle driver should be replaced by the torque

ratchet drivers to place the implant in the planned position. This procedure preserves both the

contra-angle driver and the contra-angle bearings themselves, extending their life expectancy

and preventing contra-angle drivers from locking inside the contra-angles.

DriversInstalation drivers have six marks that coincide with the six flat sides of the implant’s hex

prosthetic index. Upon Instalation, one of the driver marks should be in the vestibular position,

in order to streamline the later prosthetic procedure.

20

Page 19: Neodent Product Catalogue - 2013

21

CMExact Line

Index Implant VersatilityCM Implants with Prosthetic Index remain compatible with

the entire CM prosthetic Abutments line which you are

already familiar with, however the Exact line is compatible

only with index CM implants.

Contact one of our expert assistants through Customer

Service at +55 41 2169 1030 and discover the

advantages of the new Morse Taper implants and the

entire Exact prosthetic Abutments line.

Besides a single CM interface for all implant diameters except for the WS and Zygomatic, CM implants now welcome another Abutments line, the EXACT LINE. These Abutmentes include, at the end of the cone, a hex index that allows positioning the prosthesis over the implant (prostethic indexing), adding even more versatility to the Morse Taper Line.

Conventional or Exact Abutments

Only conventional Abutments

21

CM Index Implants CM Implant

Page 20: Neodent Product Catalogue - 2013

22

PRODUCTFEATURES:

:: Morse Taper Interface:

:: Acqua Surface;

:: Implant with Conical central core;

:: Cervical Taper to reduce compressive tension on the bone;

:: Double and progressive threads;

:: Counterclockwise cutting chambers;

:: Blade shaped apex thread;

:: Instalation is performed with CM drivers (see page 160),

allowing the implant capture directly from the package,

offering greater safety and speed;

:: Recommended for type III and IV bones and post-extraction;

:: Single prosthetic interface for all implant diameters;

:: For better prosthetic resolution, we recommend the Instalation of

a 2mm infra-bone implant level;

:: Drilling rotation: 500 - 800 rpm;

:: Insertion rotation: 30 rpm.

DriveCM

DRILL SEQUENCEAlvim2.0

Starter Alvim3.5

Alvim4.3

Alvim5.0

3.5mm

4.3mm

5.0mm

Page 21: Neodent Product Catalogue - 2013

23

M o r s e Ta p e r

8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm

Ø 3.5

Ø 4.3

Ø 5.0

140.692 140.682 140.693 140.683 140.684

140.689 140.688 140.627 140.628 140.629

140.690 140.685 140.691 140.686 140.687

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mmPerfil

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

CM cover screw

117.013

117.017

:: Use 1.2 mm digital driver (104.007)

for Instalation;

:: Do not exceed 10N.cm torque.

:: Use 1.2 mm digital driver

(104.007) for Instalation;

:: Do not exceed 10N.cm torque.

Healings

Page 22: Neodent Product Catalogue - 2013

24

PRODUCTFEATURES:

:: Implant with Conical central core;

:: Morse Taper Interface:

:: NeoPoros Surface;

:: Cervical Taper to reduce compressive tension on the bone;

:: Double and progressive threads;

:: Counterclockwise cutting chambers;

:: Blade shaped apex thread;

:: Instalation is performed with CM drivers (see page 160),

allowing the implant capture directly from the package,

offering greater safety and speed;

:: Recommended for type III and IV bones and post-extraction;

:: Cover Screw not included;

:: Single prosthetic interface for all implant diameters;

:: For better prosthetic resolution, we recommend the Instalation of

a 2mm infra-bone implant level;

:: Drilling rotation: 500 - 800 rpm;

:: Insertion rotation: 30 rpm.

DriveCM

DRILL SEQUENCEAlvim2.0

Starter Alvim3.5

Alvim4.3

Alvim5.0

3.5mm

4.3mm

5.0mm

Page 23: Neodent Product Catalogue - 2013

25

M o r s e Ta p e r

8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm

Ø 3.5

Ø 4.3

Ø 5.0

109.692 109.682 109.693 109.683 109.684

109.689 109.688 109.627 109.628 109.629

109.690 109.685 109.691 109.686 109.687

CM cover screw

117.013

117.017

:: Use 1.2 mm digital driver

(104.007) for Instalation;

:: Do not exceed 10N.cm torque.

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

:: Use 1.2 mm digital driver

(104.007) for Instalation;

:: Do not exceed 10N.cm torque.

Healings

Perfil

Page 24: Neodent Product Catalogue - 2013

26

PRODUCTFEATURES:

:: Cylinder body implant with Morse Taper interface;

:: Acqua Surface;

:: Instalation is performed with CM drivers (see page 160),

allowing the implant capture directly from the package,

offering greater safety and speed;

:: Dual thread (faster Instalation with less trauma);

:: High compacting power (bone expansion);

:: Recommended for type III and IV bones and for narrow bone

width areas due to sub-instrumentation;

:: Cover screw not included;

:: Single prosthetic interface for all implant diameters;

:: Cervical diameter equal do implant body diameter;

:: Ease of instrumentation when preparing the surgical alveolus;

:: For better prosthetic resolution, we recommend the Instalation of

a 2mm infra-bone implant;

:: Drilling rotation: 800 - 1200 rpm;

:: Insertion rotation: 30 rpm.

DRILL SEQUENCETitamax

2.0Starter Pilot

2/3Titamax

2.8Titamax

3.0

3.5mm

3.75mm

4.0mm

*Optional

Page 25: Neodent Product Catalogue - 2013

27

M o r s e Ta p e r

9.0 mm 11.0 mm 15.0 mm13.0 mm 17.0 mm

Ø 3.5

Ø 3.75

Ø 4.0

140.661 140.662 140.664140.663 140.665

140.666 140.667 140.669140.668 140.670

140.636 140.637 140.639140.638 140.640

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

CM cover screw

117.013

117.017

:: Use 1.2 mm digital driver (104.007)

for Instalation;

:: Do not exceed 10N.cm torque.

:: Use 1.2 mm digital driver

(104.007) for Instalation;

:: Do not exceed 10N.cm torque.

Healings

Perfil

Page 26: Neodent Product Catalogue - 2013

28

DRILL SEQUENCETitamax

2.0Starter Pilot

2/3Titamax

2.8Titamax

3.0

3.5mm

3.75mm

4.0mm

*Optional

PRODUCTFEATURES:

:: Cylinder body implant with Morse Taper interface;

:: NeoPoros Surface;

:: Instalation is performed with CM drivers (see page 160),

allowing the implant capture directly from the package,

offering greater safety and speed;

:: Dual thread (faster Instalation with less trauma);

:: High compacting power (bone expansion);

:: Recommended for type III and IV bones and for narrow bone

width areas due to sub-instrumentation;

:: Cover screw not included;

:: Single prosthetic interface for all implant diameters;

:: Cervical diameter equal do implant body diameter;

:: Ease of instrumentation when preparing the surgical alveolus;

:: For better prosthetic resolution, we recommend the Instalation of

a 2mm infra-bone implant;

:: Drilling rotation: 800 - 1200 rpm;

:: Insertion rotation: 30 rpm.

Page 27: Neodent Product Catalogue - 2013

29

M o r s e Ta p e r

9.0 mm 11.0 mm 15.0 mm13.0 mm 17.0 mm

Ø 3.5

Ø 3.75

Ø 4.0

109.661 109.662 109.664109.663 109.665

109.666 109.667 109.669109.668 109.670

109.636 109.637 109.639109.638 109.640

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

CM cover screw

117.013

117.017

:: Use 1.2 mm digital driver (104.007)

for Instalation;

:: Do not exceed 10N.cm torque.

:: Use 1.2 mm digital driver

(104.007) for Instalation;

:: Do not exceed 10N.cm torque.

Healings

Perfil

Page 28: Neodent Product Catalogue - 2013

30

PRODUCTFEATURES:

NEW APEXSeamless adaptation between drill and cortical implant

:: Cylinder body implant with Morse Taper interface;

:: NeoPoros Surface;

:: Instalation is performed with CM drivers (see page 160), allowing

the implant capture directly from the package, offering greater

safety and speed;

:: Dual thread (faster Instalation with less trauma);

:: High cutting power;

:: Recommended for bone types I and II and block grafting areas;

:: Cover screw not included;

:: Single prosthetic interface for all implant diameters;

:: Cervical diameter equal do implant body diameter;

:: Note the specific Pilot Drill (countersink function);

:: For better prosthetic resolution, we recommend the Instalation of

a 2mm infra-bone implant level;

:: Drilling rotation: 800- 1200 rpm;

:: Insertion rotation: 30 rpm.

TitamaxCMCortical

DRILL SEQUENCETitamax

2.0Starter Pilot

2/3Titamax

2.8Titamax

3.15Titamax

3.3Pilot CM3.3 / 4.0

Titamax4.3

Titamax3.0

Pilot CM2.8 / 3.5

Pilot CM3 / 3.75

Titamax3.8

Pilot CM4.3 / 5.0

3.5mm

3.75mm

4.0mm

5.0mm

*Optional

Page 29: Neodent Product Catalogue - 2013

31

M o r s e Ta p e r

7.0 mm 8.0 mm 9.0 mm 11.0 mm 15.0 mm13.0 mm 17.0 mm

Ø 3.5

Ø 3.75

Ø 4.0

Ø 5.0

109.613 109.614 109.615 109.616 109.618109.617 109.619

109.606 109.607 109.608 109.609 109.611109.610 109.612

109.630

109.642

109.631

109.643

109.632

109.644

109.633 109.634

109.645

109.620 109.635

109.646

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

CM cover screw

117.013

117.017

:: Use 1.2 mm digital driver (104.007)

for Instalation;

:: Do not exceed 10N.cm torque.

:: Use 1.2 mm digital driver

(104.007) for Instalation;

:: Do not exceed 10N.cm torque.

Healings

Perfil

Page 30: Neodent Product Catalogue - 2013

32

AlvimCM

DRILL SEQUENCEAlvim2.0

Starter Alvim3.5

Pilot CM2.8 / 3.5

Pilot CM3.6 / 4.3

Pilot CM4.3 / 5.0

Alvim4.3

Alvim5.0

3.5mm

4.3mm

5.0mm

*Optional

PRODUCTFEATURES:

:: Conical body implant with Morse Taper interface;

:: NeoPoros Surface;

:: Instalation is performed with CM drivers (see page 160),

allowing the implant capture directly from the package,

offering greater safety and speed;

:: Dual thread (faster Instalation with less trauma);

:: Recommended for type III and IV bones and post-extraction;

:: Cover screw not included;

:: Cervical diameter equal do implant body diameter;

:: Single prosthetic interface for all implant diameters;

:: Note the specific Pilot Drill (countersink function);

:: To increase prosthetic resolution, we recommend

Instalation of a 2mm infra-bone implant level;

:: Drilling rotation: 500 - 800 rpm;

:: Insertion rotation: 30 rpm.

Page 31: Neodent Product Catalogue - 2013

33

M o r s e Ta p e r

8.0 mm 10.0 mm 13.0 mm11.5 mm 16.0 mm

Ø 3.5

Ø 4.3

Ø 5.0

109.657 109.658 109.621109.659 109.660

109.647 109.648 109.622109.649 109.651

109.652 109.653 109.655109.654 109.656

Ø 3.3

Ø 4.5

5.5 mm4.5 mm3.5 mm2.5 mm1.5 mm0.8 mm

106.182 106.168 106.169 106.170 106.183 106.184

106.175 106.171 106.172 106.173 106.174 106.180

CM cover screw

117.013

117.017

:: Use 1.2 mm digital driver (104.007)

for Instalation;

:: Do not exceed 10N.cm torque.

:: Use 1.2 mm digital driver

(104.007) for Instalation;

:: Do not exceed 10N.cm torque.

Healings

Perfil

Page 32: Neodent Product Catalogue - 2013

34

:: Minimum interocclusal space of 5.0mm from mucous level; :: Single prosthesis screw retained (Anti-rotation);

:: Recommended for posterior regions; :: Consider additional 1.5 - 2.0mm of restoring material.

CM AbutmentDemonstration sequence for

Connection for1.6 Torque

Ope

n T

ray

CM Abutment Transfer

CM Abutment Analog

CM AbutmentProtection Cylinder

TorqueRatchet

TorqueRatchet

CM Abutment Cylinder

Connection for1.2mm Torque

CM Abutment32N.cm

10N.cm

CoCr

Cas

tabl

e

Tita

nium

Clos

ed

Tray

Page 33: Neodent Product Catalogue - 2013

35

M o r s e Ta p e r

CM Abutment:: Note recommended torque in corresponding sequence.

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

115.162 115.147 115.148 115.152 115.163 115.164

CM Abutment Transfer

108.039

Open Tray

Closed Tray

108.040

:: Available in Titanium;:: Anti-rotational.

CM Abutment Cylinder

CM Abutment Analog

:: Available:Castable: For Casting;Titanium: For provisional prosthesis;CoCr: Overcasting.

:: Screw included;:: Anti-rotational.

Castable

Titanium

CoCr

118.180

118.179

118.242

101.037

106.102CM AbutmentProtection Cylinder

CM AbutmentCylinder Screw

Titanium Neotorque

116.038 116.228:: Note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use TorqueRatchet (104.050);

Neotorque Application of a fine carbon-based coatthat provides a lower friction coefficient, resultingin increased pre-load.

Page 34: Neodent Product Catalogue - 2013

36

:: Minimum interocclusal space of 4.4 mm from mucous level for straight Abutments;

:: Multiple screw retained prosthesis; :: Consider additional 1.5 - 2.0mm of restoring material.

CM Mini Conical AbutmentCM Angled Conical Abutment

Demonstration sequence for

CM MiniConical Abutment

CM Mini ConicalAngled Abutment

(17° and 30°)

Connection forProsthetic Abutments

Connection for0.9 mm Torque

TorqueRatchet

Mini ConicalAbutment Analog

Mini Conical AbutmentProtection Cylinder

Connection for1.2 mm TorqueMini Conical

Abutment Cylinder

15N.cm

10N.cm

32N.cm

Cas

tabl

e

Tita

nium

CoCr

/ N

oble

Ope

n T

ray

Clos

ed

Tray

Mini ConicalAbutment Transfer

TorqueRatchet

Page 35: Neodent Product Catalogue - 2013

37

M o r s e Ta p e r

CM Mini Conical Abutment

115.154 115.149 115.150 115.151 115.153 115.160

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm:: Note recommended torqueand sequence.

:: Height of CM angled prosthetic Abutmentsavailable on page 47.

115.16617º

115.16930º

115.167

115.170

115.168

115.171

1.5 mm 2.5 mm 3.5 mmCM AngledConical Abutment

Mini ConicalAbutment Transfer:: Available in Titanium;:: Rotational.

116.036

Ø 4.1 108.022 108.068

Open Tray

Short Screw

Multifunctional

108.021

Closed Tray

Mini ConicalAbutment Cylinder:: Available in:

Titanium: Provisional Prosthesis;CoCr: Overcasting;Castable: For Casting;Noble: Noble alloy with highmelting point.

:: Screw included;:: Rotational for multiple screwretained elements.

Castable Titanium Noble CoCr Welding CoCr

118.112Ø 4.1 118.113 118.206 118.209 118.210

Mini ConicalAbutment Analog Ø 4.1 101.020

Mini ConicalAbutment Protection Cylinder Ø 4.1 106.054

CM Mini AbutmentCylinder Screw

Titanium Neotorque

116.037 116.227:: Note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use TorqueRatchet (104.050);

Neotorque :: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

Page 36: Neodent Product Catalogue - 2013

38

:: Minimum interocclusal space of 3.5 mm from mucous level; :: Multiple screw retained prosthesis;

:: Recommended for CM Implants close to each other; :: Consider additional 1.5 - 2.0mm of restoring

material.

CM Micro AbutmentDemonstration sequence for

Connection forProsthetic Abutments

TorqueRatchet

CM MicroAbutment Transfer

Ope

n Tr

ay

Micro AbutmentAnalog

Micro AbutmentProtection Cylinder

Micro AbutmentCylinder

TorqueRatchet

Connection for1.2 mm Torque

10N.cm

32N.cm

CoCr

Cas

tabl

e

Tita

nium

CM MicroAbutment

Page 37: Neodent Product Catalogue - 2013

39

M o r s e Ta p e r

CM Micro Abutment:: Please note recommended torque and sequence. 115.200115.212 115.201 115.202 115.213

1.5 mm0.8 mm 2.5 mm 3.5 mm 4.5 mm

CM Micro Abutment Transfer:: Available in Titanium;:: Rotational.

108.070

Rotational

CM Micro Abutment Cylinder:: Available in:

Titanium: Provisional Prosthesis;CoCr: Overcasting;Castable;

:: Screw included;:: Rotational for multiple screw retained elements.

118.246

Titanium

118.245 118.247

CoCr Castable

CM MicroAbutment Analog 101.057

CM Abutment Cylinder Screw Titanium Neotorque

116.037 116.227:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet(104.050);

Neotorque :: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

CM Micro AbutmentProtection Cylinder 106.199

Page 38: Neodent Product Catalogue - 2013

40

:: Cemented single prosthesis; :: Customizable; :: Recommended for anterior regions.

CM and ExactAnatomic Post

Demonstration sequence for

CM ImplantTransfer

CM AnatomicPost

CM Implant Analog

Connection for 0.9 mm Torque

Connectionfor 0.9 mm Torque

Lab Stage

Optional Sequence

ProsthesisCompleted

TorqueRatchet

TorqueRatchet

Customization,if needed

Conventional Castable

Lab Stage

Recommended sequence

15N.cm

15N.cm

Clos

ed E

xact

Tra

y

Clos

ed T

ray

Ope

n Tr

ay

Page 39: Neodent Product Catalogue - 2013

41

M o r s e Ta p e r

CM ExactAnatomic Post

CM AnatomicPost

CM AnatomicSide Post

CM Exact AnatomicSide Post

:: Please note recommended torque;:: Exclusive Exact Abutment forCM Index implants;:: Height of anatomic prostheticAbutments available on page 46.

1.5 mm 2.5 mm 3.5 mm

114.422 114.423 114.424

1.5 mm 2.5 mm 3.5 mm

114.328 114.329 114.330

1.5 mm 2.5 mm 3.5 mm

114.419 114.420 114.421

1.5 mm 2.5 mm 3.5 mm

114.425 114.426 114.427

CM Implant Transfer:: Available in Titanium;:: Lengths: - Short: 15 mm; - Conventional: 20 mm.

CM ImplantAnalog

108.069

Short

Exact

Conventional

Open Tray

108.065

108.041

108.076

Closed Tray

101.058

Page 40: Neodent Product Catalogue - 2013

42

:: Cemented single prosthesis.

Demonstration sequence forDemonstration sequence for

CM Universal PostCM Universal Angled Post

Connection for1.2mm Torque

TorqueRatchet

CM PostTransfer

CM PostAnalog

Universal PostCylinder

Cas

tabl

e

15N.cm

32N.cm

CM Universal Post

Alu

min

a

Prov

isio

nal

CM UniversalAngled Post

Connection for0.9 mm Torque

Page 41: Neodent Product Catalogue - 2013

43

M o r s e Ta p e r

CM Universal Post:: Please note sequence and torque control;:: Universal Post height available on page 46.

:: Please note sequence and torque control.

114.129 114.077 114.078 114.079 114.136 114.137

114.130 114.086 114.087 114.088 114.139 114.140

114.131 114.080 114.081 114.082 114.142 114.143

114.132 114.083 114.084 114.085 114.145 114.146

0.8 mm

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

CM UniversalAngled Post

17º

30º

Ø 3.3

Ø 3.3

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.5

4 m

m4

mm

6 m

m6

mm

1.5 mm 2.5 mm 3.5 mm

114.095

114.101

114.107 114.108 114.109

114.110 114.111 114.112

114.102 114.103

114.104 114.105 114.106

114.096 114.097

114.098 114.099 114.100

114.089 114.090 114.091

114.092 114.093 114.094

Universal Post Transfer

UniversalPost Cylinder:: Available in:

Acrylic: For provisional prosthesis;Alumina: For metal-free prosthesis;Castable.

:: Compatible with all Universal Posts, when not modified.

:: Available in polymer;:: Abutment with impression function to pHandleuce the prosthesis;:: For closed Tray technique (replacement);:: Select Transfer according to the Abutment to be Tray according to prosthetic planning;:: Anti-rotational.

108.042

108.044

108.043

108.045

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

118.186 118.181 118.192

118.188 118.183 118.194

118.187 118.182 118.193

118.189 118.184 118.195

ProvisionalAlumina Castable

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

UniversalPost pack

UniversalPost Analog

:: Universal Post line Abutment pack, including Transfer and Castable and Provisional Cylinders.

108.060

108.062

108.061

108.063

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

101.038

101.040

101.039

101.041

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

Page 42: Neodent Product Catalogue - 2013

44

:: Cemented single prosthesis; :: Recommended for customization or laboratory use.

CM Exact Universal Post andCM Exact Angled Universal Post

Demonstration sequence for

CM ImplantAnalog

Connection for0.9 mm Torque

CM Exact Closed Tray Implant

Transfer

CM Exact UniversalPost

Prosthesis Completed

CM Exact UniversalAngled Post

15N.cm

TorqueRatchet

Page 43: Neodent Product Catalogue - 2013

45

M o r s e Ta p e r

CM Exact Universal Post

CM Exact UniversalAngled Post

:: Please note recommended torque sequence;:: Abutment with passing screw;:: Exclusive Exact Abutment for CM Index implant.

:: Please note recommended torque sequence;:: Height of CM angled prosthetic Abutments available on page 46.

114.408 114.360 114.361 114.362 114.363 114.364

114.409 114.366 114.367 114.368 114.369 114.370

114.410 114.357 114.358 114.359 114.372 114.373

114.411 114.340 114.341 114.342 114.375 114.376

0.8 mm

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

4 m

m6

mm

1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

Ø 3.3

Ø 3.3

Ø 3.3

Ø 3.3

Ø 4.5

Ø 4.5

Ø 4.5

Ø 4.54

mm

4 m

m6

mm

6 m

m

1.5 mm 2.5 mm 3.5 mm

114.390

114.396

114.402 114.403 114.404

114.405 114.406 114.407

114.397 114.398

114.399 114.400 114.401

114.391 114.392

114.393 114.394 114.395

114.384 114.385 114.386

114.387 114.388 114.389

17º

30º

CM ImplantAnalog 101.058

CM Implant Transfer:: Available in Titanium;:: Lengths: - Short: 15 mm; - Conventional: 20 mm. 108.069

Short

Exact

Conventional

Open Tray

108.065

108.041

108.076

Closed Tray

Page 44: Neodent Product Catalogue - 2013

46

CM Anatomic Post CM Anatomic Lateral Post

8 m

m6 m

m

Tran

smuc

ous

5 mm6 mm

6.5

mm

5.3

mm

Cem

enta

ble

Profi

le4

/ 6

mm

Tran

smuc

ous

Tran

smuc

ous

4.3 mm4.7 mm

Altura do Munhão Universal, Anatômico e Lateral

46

Height 3.3 / 4.5 mm

4 m

m

4 m

m 6 m

m

6 m

m

Ø 4.5 mmØ 3.3 mm

Ø 4.5 mmØ 3.3 mm

Universal Post

Anatomic Post

Universal, Anatomic and Lateral Post Height

Page 45: Neodent Product Catalogue - 2013

47

M o r s e Ta p e r

Universal Angled Post

Ø 4.5Ø 3.3

Mini Conical Angled Abutment

30º

17º

30º17º

5.80

4.50

5.20

4.90

4.80

3.50

4.20

3.90

3.80

2.50

3.20

2.90

3.50

3.50

3.50

3.50

4.90

3.50 5.90

3.50

2.50

2.50

2.50

2.50

3.90

2.50 4.

90

2.50

1.50

1.50

1.50

1.50

2.90

1.50 3.

90

1.50

Altura dos Abutmentes Protéticos Angulados CM

47

Height of CM Angled Prosthetic Abutments

Page 46: Neodent Product Catalogue - 2013

48

:: Recommended in-mouth capture, one Abutment at a time;

:: Use of positioner is mandatory for capturing;

:: O’ring with cylinder and protection disc included;

:: Refer to demonstration sequence for CM Mini Ball Attachment on page 142.

Protection Disc Positioner

CM Mini Ball AttachmentDemonstration sequence for

Connection forProsthetic Abutments

7º 14º

ProtectionDisc

32N.cm

Positioners

CM Mini BallAttachment

TorqueRatchet

straight

O’ring withCylinder

Page 47: Neodent Product Catalogue - 2013

49

M o r s e Ta p e r

CM Mini BallAttachment:: Please note sequence andrecommended torque control

Castable BallAttachment

:: Castable polymer;:: May be cemented on natural roots or waxed onto overdentures retaining bars.

102.078

Positioners:: Refer to sequence on page 142. straight , 70 e 140

102.076

Protection Disc:: Package with 10 units.

102.077

O’ring with cylinder:: Protection Disc included;:: Titanium cylider and polymer o’ring.

102.073

Pink O’ring:: Available in polymer. 102.075

O’ring remover:: Digital Driver to remove the o’ring from the cylinder.

104.044

O’ring assembler

:: Digital Driver to replace the o’ring on the cylinder.

104.043

102.069 102.070 102.071 102.097

1.5 mm 2.5 mm 3.5 mm 4.5 mm

Page 48: Neodent Product Catalogue - 2013

50

Solution for the limitation of External Hex

Implants

External Hex

50

Page 49: Neodent Product Catalogue - 2013

51

E x t e r n a l

H e x

Internal torque area.

Clip ensures greater safety in implant transport.:: Ensures the external hex integrity;

:: Maintains original rotational freedom;

:: Increased practicality and safety;

:: Increased mechanical resistance to insertion;

:: Transport clip for safety in implant handling.

Abutment Indication Table

Ø 3.3

Ø 4.1

Ø 4.3

Ø 5.0

•Castable UCLA•CoCr UCLA

•SF Mini Conical Abutment (multiple)

•Mini Conical Angled Abutment 17° and 30° (multiple)

•SF Conical Abutment (single)•Castable UCLA•Noble UCLA•CoCr UCLA

•Mini Conical Abutment (multiple)

•Mini Conical Angled Abutment 17° and 30° (multiple)

•Conical Abutment (single)•Castable UCLA•CoCr UCLA

•SF Mini Conical Abutment (multiple)

•Mini Conical Angled Abutment 17° and 30° (multiple)

•SF Conical Abutment (single)•Castable UCLA•CoCr UCLA

•Angled Post 17°•Universal Post•Castable UCLA•Titanium UCLA•CoCr UCLA

•Mini Ball Attachment

•Angled Post 17° and 30°•Universal Post•Customizable Post•Castable UCLA•Noble UCLA•Titanium UCLA•CoCr UCLA

•Mini Ball Attachment •Mini Conical Abutment•Mini Conical Angled Abutment

17° and 30°•Cylinder and Ext. Distal Bar

Passive Fitting Technique•Castable Cylinder Mini Conical Abut.•Titanium Cylinder Mini Conical Abut.•Brass Cylinder Mini Conical Abut.

•Mini Conical Abutment•Mini Conical Angled Abutment 17°

and 30°•Cylinder and Ext. Distal Bar

Passive Fitting Technique•Castable Cylinder Mini Conical Abut.•Titanium Cylinder Mini Conical Abut.•Brass Cylinder Mini Conical Abut.

•Angled Post 17°•Castable UCLA•Titanium UCLA•CoCr UCLA

3.3 and 3.5 mm

3.75 and 4.0 mm

4.3 mm

4.5 and 5.0 mm

EXTERNALHEX

Inne

r Thr

ead

Ø 1.

8In

ner T

hrea

d Ø

2.0

Inne

r Thr

ead

Ø 2.

0In

ner T

hrea

d Ø

2.5

•Angled Post 17°•Customizable Post•Castable UCLA•Titanium UCLA•CoCr UCLA

•Mini Ball Attachment •Mini Conical Abutment•Mini Conical Angled Abutment

17° and 30°•Cylinder and Ext. Distal Bar

Passive Fitting Technique•Castable Cylinder Mini Conical Abut.•Titanium Cylinder Mini Conical Abut.•Brass Cylinder Mini Conical Abut.

Screw Retained Prosthesis

Cemented Prosthesis

Overdenture Protocol

51

Ø4.1 mm

Ø3.5 mm

0.7 mm

Hex 3.3 mm

Ø 5.0 mm

Hex 2.7 mm

Hex 2.7 mm

Ø 4.3 mm

1 mm

Hex 2.37 mm

1 mm

1 mm

External HexImplants

Page 50: Neodent Product Catalogue - 2013

52

PRODUCTFEATURES:

:: External Hex Interface;

:: Acqua Surface;

:: Instalation is performed with Ti drivers (see page 160), allowing

the implant capture directly from the package, offering greater

safety and speed;

:: Implant with Conical central core;

:: Double and progressive threads;

:: Counterclockwise cutting chambers;

:: Blade shaped apex thread;

:: Recommended for type III and IV bones and post-extraction;

:: Drilling rotation: 500 - 800 rpm;

:: Insertion rotation: 30 rpm.

DRILL SEQUENCEAlvim2.0

Starter Alvim3.5

Alvim4.3

Alvim5.0

3.5mm

4.3mm

5.0mm

Page 51: Neodent Product Catalogue - 2013

53

E x t e r n a l

H e x

8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm

Ø 3.5

Ø 4.3

Ø 5.0

140.752 140.753 140.754 140.755 140.756

140.757 140.758 140.759 140.760 140.761

140.762 140.763 140.764 140.765 140.766

106.065

106.140

106.127 106.128 106.129

106.066

106.141

106.067

106.142

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Ø 4.3

Ø 5.0

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 5.0

Slim Fit Healings

106.195 106.196 106.197

Cover screw

117.001

117.006

117.003

3.3 mm

4.3 mm

5.0 mm

:: Use a 0.9mm digital driver (104.039) to install the cover

screw platform 3.3 and 4.3 and a 1.2mm digital driver

(104.007) to install a cover screw platform 5.0;

2.0 mm 3.0 mm 4.0 mm

Parallel Healings

Ø 3.3 106.060 106.061 106.062

Ø 4.3 106.132 106.133 106.134

Platform(3.3)

Platform(4.3)

Platform(5.0)

Page 52: Neodent Product Catalogue - 2013

54

PRODUCTFEATURES:

:: External Hex Interface;

:: NeoPoros Surface;

:: Instalation is performed with Ti drivers (see page 160), allowing

the implant capture directly from the package, offering greater

safety and speed;

:: Implant with Conical central core;

:: Double and progressive threads;

:: Counterclockwise cutting chambers;

:: Blade shaped apex thread;

:: Recommended for type III and IV bones and post-extraction;

:: Drilling rotation: 500 - 800 rpm;

:: Insertion rotation: 30 rpm.

DRILL SEQUENCEAlvim2.0

Starter Alvim3.5

Alvim4.3

Alvim5.0

3.5mm

4.3mm

5.0mm

Page 53: Neodent Product Catalogue - 2013

55

E x t e r n a l

H e x

8.0 mm 10.0 mm 11.5 mm 13.0 mm 16.0 mm

Ø 3.5

Ø 4.3

Ø 5.0

109.752 109.753 109.754 109.755 109.756

109.757 109.758 109.759 109.760 109.761

109.762 109.763 109.764 109.765 109.766

106.065

106.140

106.127 106.128 106.129

106.066

106.141

106.067

106.142

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Ø 4.3

Ø 5.0

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 5.0

Slim Fit Healings

106.195 106.196 106.197

Cover screw

117.001

117.006

117.003

3.3 mm

4.3 mm

5.0 mm

:: Use a 0.9mm digital driver (104.039) to install the cover

screw platform 3.3 and 4.3 and a 1.2mm digital driver

(104.007) to install a cover screw platform 5.0;

2.0 mm 3.0 mm 4.0 mm

Parallel Healings

Ø 3.3 106.060 106.061 106.062

Ø 4.3 106.132 106.133 106.134

Platform(3.3)

Platform(4.3)

Platform(5.0)

Page 54: Neodent Product Catalogue - 2013

56

PRODUCTFEATURES:

:: Cylinder body implant with external hex interface;

:: Acqua Surface;

:: Instalation is performed with Ti drivers (see page 160), allowing the

implant capture directly from the package, offering greater safety and

speed;

:: Instalation through implant’s internal hex, increasing mechanical

resistance when high torques are applied, preserving the external hex

integrity;

:: Dual thread (faster Instalation with less trauma);

:: High compacting power (bone expansion);

:: Recommended for type III and IV bones;

:: Cover screw not included;

:: Ease of instrumentation when preparing the surgical alveolus;

:: Drilling rotation: 800 - 1200 rpm;

:: Instalation rotation: 30 rpm.

DRILL SEQUENCETitamax

2.0Starter Pilot

2/3Titamax

2.8Titamax

3.0

3.75mm

4.0mm

*Optional

Page 55: Neodent Product Catalogue - 2013

57

E x t e r n a l

H e x

9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm

Ø 4.0

Ø 3.75

140.588

140.582

140.589

140.583

140.590

140.584

140.591

140.585

140.592

140.586Platform

(4.1)

Platform(4.1)

Cover screw

117.0184.1 mm

:: Use a 0.9mm digital driver (104.039) to install the cover

screw platform 4.1;

:: Do not exceed 10N.cm torque.

106.092 106.093 106.094

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Slim Fit Healings

106.190 106.191 106.192

Page 56: Neodent Product Catalogue - 2013

58

PRODUCTFEATURES:

:: Cylinder body implant with external hex interface;

:: NeoPoros Surface;

:: Instalation is performed with Ti drivers (see page 160),

allowing the implant capture directly from the package,

offering greater safety and speed;

:: Instalation through implant’s internal hex, increasing mechanical

resistance when high torques are applied, preserving the

external hex integrity;

:: Dual thread (faster Instalation with less trauma);

:: High compacting power (bone expansion);

:: Recommended for type III and IV bones;

:: Cover screw not included;

:: Ease of instrumentation when preparing the surgical alveolus;

:: Drilling rotation: 800 - 1200 rpm;

:: Instalation rotation: 30 rpm.

DRILL SEQUENCETitamax

2.0Starter Pilot

2/3Titamax

2.8Titamax

3.0

3.75mm

4.0mm

*Optional

Page 57: Neodent Product Catalogue - 2013

59

E x t e r n a l

H e x

9.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm

Ø 4.0

Ø 3.75

109.588

109.582

109.589

109.583

109.590

109.584

109.591

109.585

109.592

109.586Platform

(4.1)

Platform(4.1)

106.092 106.093 106.094

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Slim Fit Healings

106.190 106.191 106.192

Cover screw

117.0184.1 mm

:: Use a 0.9mm digital driver (104.039) to install the cover

screw platform 4.1.

Page 58: Neodent Product Catalogue - 2013

60

PRODUCTFEATURES:

Cortical

:: Cylinder body implant with External Hex interface;

:: NeoPoros Surface;

:: Instalation is performed with Ti drivers (see page 160),

allowing the implant capture directly from the package, offering greater

safety and speed;

:: Instalation through implant’s internal hex, increasing mechanical

resistance when high torques are applied, preserving the external hex

integrity;

:: Dual thread (faster Instalation with less trauma);

:: High cutting power;

:: Recommended for bone types I and II and block grafting areas;

:: Cover screw and assembler not included;

:: Drilling rotation: 800 - 1200 rpm;

:: Instalation rotation: 30 rpm.

DRILL SEQUENCETitamax

2.0Titamax

2.8Titamax

3.3Titamax

3.15Starter Pilot

2/3Countersink

3.5Pilot

3/3.75Titamax

3.0Countersink

4.1 SFCountersink

5.0 SFTitamax

3.8Titamax

4.3

3.5mm

3.75mm

4.0mm

4.5mm

5.0mm

*Optional

NEW APEXSeamless adaptation between drill and cortical implant

Page 59: Neodent Product Catalogue - 2013

61

E x t e r n a l

H e x

9.0 mm7.0 mm 11.0 mm 13.0 mm 15.0 mm 17.0 mm

Ø 4.0

Ø 3.75

Ø 3.3

Platform(4.1)

Platform(3.3)

Platform(4.1)

Platform(5.0)

Platform(5.0)

Ø 4.5

Ø 5.0

109.284 109.285

109.713109.712

109.286

109.714

109.287

109.715

109.288

109.716

109.302 109.303 109.304 109.305 109.306

109.327 109.328 109.329

109.294 109.295 109.296 109.297

106.065

106.092

106.127 106.128 106.129

106.066

106.093

106.067

106.094

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Ø 4.1

Ø 5.0

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 4.1

Ø 5.0

Slim Fit Healings

106.195 106.196 106.197

106.190 106.191 106.192

Cover screw

117.001

117.018

117.003

3.3 mm

4.1 mm

5.0 mm

:: Use a 0.9mm digital driver (104.039) to install the cover

screw platform 3.3 and 4.3 and a 1.2mm digital driver

(104.007) to install a cover screw platform 5.0;

2.0 mm 3.0 mm 4.0 mm

Parallel Healings

Ø 3.3 106.060 106.061 106.062

Page 60: Neodent Product Catalogue - 2013

62

PRODUCTFEATURES:

:: Conical body implant with external hex interface;

:: NeoPoros Surface;

:: Instalation is performed with Ti drivers (see page 160), allowing the

implant capture directly from the package, offering greater safety and

speed;

:: Capture and Instalation with contra-angle or manual, without using

assemblers (reduces surgery time);

:: Instalation through implant’s internal hex, increasing mechanical

resistance when high torques are applied, preserving the external hex

integrity;

:: Recommended for type III and IV bones and post-extraction;

:: Cover screw and assembler not included;

:: 1mm tall external hex;

:: Drilling rotation: 500 - 800 rpm;

:: Instalation rotation: 30 rpm.

DRILL SEQUENCEAlvim2.0

Alvim5.0

Starter Alvim3.5

Countersink3.5

Countersink5.0 SF

Alvim4.3

Countersink4.3

3.5mm

4.3mm

5.0mm

*Optional

Page 61: Neodent Product Catalogue - 2013

63

E x t e r n a l

H e x

Ø 5.0

Ø 4.3

Ø 3.5

10.0 mm 13.0 mm 16.0 mm

109.321

109.717

109.322

109.718

109.323

109.719

109.324 109.325 109.326

2.0 mm 3.0 mm 4.0 mm

Ø 5.0

Slim Fit Healings

106.195 106.196 106.197

106.065

106.140

106.127

106.141

106.128

106.142

106.129

106.066 106.067

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Ø 4.3

Ø 5.0

Divergent Healings

2.0 mm 3.0 mm 4.0 mm

Ø 3.3

Ø 4.3

Parallel Healings

106.060

106.132

106.061

106.133

106.062

106.134

Cover screw

117.006117.001 117.003

4.3 mm3.3 mm 5.0 mm

:: Use a 0.9mm digital driver (104.039) to install the cover screw

platform 3.3 and 4.3 and a 1.2mm digital driver (104.007) to install

a cover screw platform 5.0;

:: Do not exceed 10N.cm torque.

Platform(3.3)

Platform(4.3)

Platform(5.0)

Page 62: Neodent Product Catalogue - 2013

64

SlimFITExternal Hex

Discover the benefits of the SlimFIT line and find out why

certain details make all the difference:

:: Ease of Fitting the prosthetic Abutment by reducing

interference with the marginal bone;

:: Preserves marginal bony plates;

:: Optimizes Instalation;

:: Ease of soft tissue synthesis procedures (suture) by increasing

the mini conical abutment tapering.

CONVENTIONAL MINI CONICAL ABUTMENT WITH SF OSTEOTOMY

SF MINI CONICAL ABUTMENT WITH

CONVENTIONAL OSTEOTOMY

SHORTENINGOSTEOTOMY

The SlimFIT line is Neodent’s innovation for

External Hex Abutments, due to the rising parallel profile

that minimizes bone removal.

64

Page 63: Neodent Product Catalogue - 2013

65

E x t e r n a l

H e x

Accomodation of Soft Tissue

SlimFIT intermediaries provide excellent

accommodation for peri-implant soft tissue,

streamlining the prosthetic procedures in cases with

immediate loading and long term tissue stabilization.

For the SlimFit line, you need to

use the new SF Countersink drill,

with a new shape that reduces the

drilling diameter and causes less

trauma, preserving bone tissue.

Conventional rising profile

SlimFIT rising profile

CONVENTIONAL OSTEOTOMY

CONVENTIONAL COUNTERSINK

SlimFIT OSTEOTOMY(REDUCED BONE REMOVAL)

NEW DRILLCOUNTERSINK SlimFIT

65

Page 64: Neodent Product Catalogue - 2013

66

Connection for1.2 Torque

SF ConicalAbutment 4.1mm

ConicalAbutment 4.3mm

ConicalAbutment 5.0mm

Connection forProsthetic Abutments

Connection for1.6 mm Torque

Conical AbutmentAnalog 4.1 and 5.0

Conical AbutmentProtection Cylinder 4.1 and 5.0

Ope

n Tr

ay

Clos

ed T

ray

Conical AbutmentTransfer 4.1 and 5.0

:: Minimum interocclusal space of 6.1mm for platform 4.1, and 6.7mm for platform 5.0 from the mucous level;

:: Single screw retained prosthesis (anti-rotational); :: Installed after using the Countersink drill, minimizing

bone removal; :: SF Abutments improve tissue accommodation; :: Consider additional 1.5 - 2.0mm of restoring

material.

SF Conical AbutmentDemonstration sequence for

20N.cm

10N.cm

Conical AbutmentCylinder 4.1 and 5.0

CoCr

Cas

tabl

e

Tita

nium

TorqueRatchet

TorqueRatchet

Page 65: Neodent Product Catalogue - 2013

67

E x t e r n a l

H e x

:: Please note recommended torque and sequence.

SF Conical Abutment1 mm 2 mm

Ø 4.1

Ø 5.0

Ø 4.3

3 mm

Slim

Fit

115.051 115.052 115.053

115.007 115.008 115.009

115.192 115.193 115.194

ConicalAbutment Transfer:: Anti-rotational.

Ø 4.1

Ø 5.0

108.035

108.025 108.104

Open Tray

108.075

Closed Tray

ConicalAbutment Cylinder:: Available:

Titanium: For provisional prosthesis;CoCr: Overcasting;Castable: For Casting.

:: Screw included.

Castable Titanium CoCr

Ø 4.1

Ø 5.0

118.106 118.107 118.233

118.253118.110 118.111

Conical Abutment AnalogØ 4.1

Ø 5.0 101.030

101.027

Conical AbutmentCylinder Screw:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use TorqueRatchet (104.050).

Neotorque:: Application of a fine carbon-based coat that provides a lower friction coefficient,resulting in increased pre-load.

Ø 4.1

Ø 5.0

Titanium Neotorque

116.004 116.231

116.005 116.232

Conical AbutmentProtection Cylinder:: Used to protect the Abutment duringprosthesis production;:: For Instalation, use a 1.2mm Digital Driver(104.007).

Ø 4.1

Ø 5.0

106.051

106.052

Page 66: Neodent Product Catalogue - 2013

68

Connection for1.2mm Torque

Connection for1.2mm Torque

Connection forProstheticAbutments

Connection forProstheticAbutments

Connection for1.6mm Torque

Angled MiniConical Abutment

17° and 30°

Mini ConicalAbutment

3.3mm and 4.3mm

SF Mini ConicalAbutment 4.1mm

SF Mini ConicalAbutment 5.0mm

SF Mini Conical AbutmentAngled Mini Conical Abutment

Demonstration sequence for

:: Minimum interocclusal space of 4.4 mm for platform 4.1, and 4.8 mm for platform 5.0 from the mucous

level; :: Multiple (rotational) screw retained prosthesis; :: Angled Mini Conical Abutment provides 12 fitting

positions; :: Installed after using the Countersink drill, minimizing bone removal; :: SF Abutments improve tissue

accommodation; :: Consider additional 1.5 - 2.0mm of restoring material.

20N.cm

20N.cm

32N.cm

32N.cm

Ope

n Tr

ay

Clos

ed T

ray

Mini ConicalAbutment Transfer

4.1 and 5.0

Mini Conical AbutmentAnalog 4.1 and 5.0

Mini Conical AbutmentProtection Cylinder 4.1 and 5.0

10N.cm

Mini Conical AbutmentCylinder 4.1 and 5.0

CoCr

Cas

tabl

e

Tita

nium

TorqueRatchet

TorqueRatchet

Page 67: Neodent Product Catalogue - 2013

69

E x t e r n a l

H e x

SF Mini Conical Abutment:: Please note sequence corresponding to the listed Abutment diameter and torque.

1 mm 2 mm

115.187 115.188

115.054

115.134

115.055

115.135

115.056

115.136

115.057

115.197 115.198 115.199

Ø 4.1

Ø 5.0

Ø 4.3

Ø 3.3

3 mm 4 mm

115.189 115.190

Slim

Fit

Slim

Fit

Angled MiniConical Abutment:: Please note recommended torque and sequence.

2 mm

Ø 4.1

Ø 3.3

Ø 5.0

Ø 4.3

3 mm 4 mm

115.084

115.137

115.074

115.138

115.075

115.139

115.076 115.077 115.078

115.094 115.095 115.096

17º

Ø 4.1

Ø 5.0

Ø 4.3 115.111 115.112

115.143 115.144

115.140 115.141

30º

Mini Conical Abutment Transfer

:: Available in Titanium;:: Rotational.

108.024

108.022 108.068

Short Screw

Open Tray Multifunctional

Ø 4.1

Ø 5.0 108.023

108.021

Closed Tray

116.036

Mini ConicalAbutment Cylinder

:: Available in:Titanium: Provisional Prosthesis;CoCr: Overcasting;Castable: For Casting;Noble: Noble alloy with high melting point.

:: Screw included;:: Rotational for multiple screw retained elements.

118.112 118.113

118.114 118.115 118.240

Castable Titanium

118.206 118.209 118.210

Noble CoCr WeldingCoCr

Ø 4.1

Ø 5.0

Mini ConicalAbutment Analog Ø 4.1

Ø 5.0 101.022

101.020

Mini Conical AbutmentProtection Cylinder:: For Instalation, use a 1.2mm Digital Driver (104.007).

Ø 4.1

Ø 5.0

106.054

106.055

Ø 4.1

Ø 5.0

Titanium Neotorque

116.037 116.227

116.038 116.228

Mini ConicalAbutment Cylinder Screw:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

Neotorque:: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

Page 68: Neodent Product Catalogue - 2013

70

:: Cemented prosthesis; :: The Universal Post may be modified as needed, in this case, the

prosthetic sequence cannot be used; :: Screw not included, for single elements select a

Neotorque Screw.

SF Universal PostDemonstration sequence for

TorqueRatchet

SF Universal Post

ScrewNeotorque

Connection for1.2 Torque

32N.cm

PostTransfer 4.5

PostAnalog 4.5

Universal PostCylinder 4.5

Alu

min

a

Cas

tabl

e

Prov

isio

nal

Page 69: Neodent Product Catalogue - 2013

71

E x t e r n a l

H e x

SF UniversalPost

Neotorque Titanium

116.180 116.002

1 mm

4 m

m

2 mm

6 m

m

Ø 4.5

3 mm

114.428

114.431

114.429

114.432

114.430

114.433

HexScrew:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).:: Compatible with External Hex platforms 4.1 and 4.3;

:: Compatible with External Hex platforms 4.1 and 4.3.

Neotorque:: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

:: Available in polymer;:: Abutment with impression function to pHandleuce the prosthesis;:: For closed tray technique (replacement);:: Select Transfer according to the Abutment to be Cast according to prosthetic planning;:: Anti-rotational.

UniversalPost Transfer

4 m

m6

mm

Ø 4.5

108.045

108.044

UniversalPost Analog

4 m

m6

mm

Ø 4.5

101.041

101.040

UniversalPost Assembly:: Universal Post line Abutment Kit, including Transfer and Castable and Provisional Cylinders.

4 m

m6

mm

Ø 4.5

108.062

108.063

UniversalPost Cylinder

:: Available in:Acrylic: For provisional prosthesis;Alumina: For metal-free prosthesis;Castable.

:: Compatible with all Universal Posts, when not modified.

4 m

m6

mm

Ø 4.5

118.188 118.183 118.194

118.189 118.184 118.195

ProvisionalAlumina Castable

Page 70: Neodent Product Catalogue - 2013

72

Customizable PostAngled Post

Demonstration sequence for

:: Cemented prosthesis; :: The Angled Post provides 12 fitting positions and includes a Titanium screw;

:: Customizable Post does not include screw. We recommend using a Neotorque screw.

Neotorque Screw4.1 and 5.0 mm

Titanium Screw

Customizable Post4.1 and 5.0mm

Angled Post(17° and 30°)

3.3, 4.1, 4.3 and 5.0 mm

Implant Analog3.3mm, 4.1mm, 4.3mm and 5.0mm

32N.cm

Ope

n Tr

ay

Clos

ed T

ray

Transfer3.3, 4.1, 4.3 and 5.0

TorqueRatchet

Connection for1.2mm Torque

Page 71: Neodent Product Catalogue - 2013

73

E x t e r n a l

H e x

Angled Post:: Please note recommended torque and sequence;:: Abutment includes titanium screw;:: Anti-rotational.

2 mm 3 mm

Ø 3.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

4 mm

114.025 114.026 114.027

114.016 114.017 114.018

114.049 114.050 114.051

114.071 114.072 114.073

17º

114.009 114.01030º

:: Please note recommended torque and sequence;:: Screw not included;:: Anti-rotational.

CustomizablePost Ø 4.1 for Ø 5.0

Ø 4.1 for Ø 6.0

Ø 5.0 for Ø 6.0

114.029

114.030

114.035

Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

116.188 116.001

116.189 116.003

116.180 116.002

Neotorque TitaniumHexScrew:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

Neotorque:: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

:: Available in Titanium.

ImplantTransfer

Ø 3.3

Ø 3.3

Ø 4.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

Ø 5.0 108.012

Anti-

rota

tiona

lRo

tatio

nal

108.013

108.038

108.029

108.066 (SF)

108.003

108.002

108.001

108.011

108.034

108.067 (SF)

108.006

Open TrayClosed Tray

Implant Analog

Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

101.002 101.001

Titanium Brass

101.004 101.003

101.028 101.024

101.006 101.005

Page 72: Neodent Product Catalogue - 2013

74

:: For cemented or screw retained prosthesis; :: Presentation: - CoCr: Over Castable (screw not

included); - Castable: (screw not included); - Titanium: Cemented or provisional prosthesis

(screw not included); - Noble: Over Castable with high melting point alloys. Titanium (laboratory)

and Neotorque screw included. :: For single elements, select a Neotorque screw.

UCLADemonstration sequence for

UCLA3.3, 4.1, 4.3 and 5.0mm

Analog3.3, 4.1, 4.3 and 5.0mm

Ope

n Tr

ay

Clos

ed T

ray

Transfer3.3, 4.1, 4.3 and 5.0mm

Neotorque Screw

32N.cm

Connection for1.2mm Torque

TorqueRatchet

Page 73: Neodent Product Catalogue - 2013

75

E x t e r n a l

H e x

:: Available in Titanium.

ImplantTransfer

Ø 3.3

Ø 3.3

Ø 4.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

Ø 5.0 108.012

Anti-

rota

tiona

lRo

tatio

nal

108.013

108.038

108.029

108.066 (SF)

108.003

108.002

108.001

108.011

108.034

108.067 (SF)

108.006

Open TrayClosed Tray

UCLA

Ø 3.3

Ø 3.3

Ø 4.3

Ø 4.3

Ø 4.1

Ø 4.1

Ø 5.0

Ø 5.0

Anti-

rota

tiona

lRo

tatio

nal

118.204

118.097

118.009

118.040

118.212

118.235

118.237 118.006

118.101

118.004

118.001

CastableCobalt-Chromium(Cocr)

118.008

NobleTitanium

118.205

118.152

118.030

118.211

118.234

118.236 118.007

118.119

118.005

118.002

Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

116.188 116.001

116.189 116.003

116.180 116.002

Neotorque TitaniumHexScrew:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

Neotorque:: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

Implant Analog

Ø 3.3

Ø 4.3

Ø 4.1

Ø 5.0

101.002 101.001

Titanium Brass

101.004 101.003

101.028 101.024

101.006 101.005

Page 74: Neodent Product Catalogue - 2013

76

:: Recommended in-mouth capture, one Abutment at a time;

:: Use of positioner is mandatory for capturing;

:: Refer to demonstration sequence on page 142.

Protection Disc Positioner

Mini Ball AttachmentDemonstration sequence for

Connection forProsthetic Abutments

7º 14º

ProtectionDisc

Mini Ball Attachment4.1, 4.3 and 5.0mm

Positioners

32N.cm

TorqueRatchet

O’ring withCylinder

straight

Page 75: Neodent Product Catalogue - 2013

77

E x t e r n a l

H e x

Mini BallAttachment:: Please note sequence and recommended torque control.

Castable BallAttachment

:: Castable polymer;:: May be cemented on natural roots or waxed onto overdentures retaining bars.

102.078

Positioners:: Refer to sequence on page 142. straight , 70 e 140

102.076

Protection Disc:: Package with 10 units.

102.077

O’ring with cylinder:: Protection Disc included;:: Titanium cylider and polymer o’ring.

102.073

Pink O’ring:: Available in polymer. 102.075

O’ringremover:: Digital Driver to remove the O’ring from the cylinder.

104.044

O’ringAssembler:: Digital Driver to replace the O’ring on the cylinder.

104.043

Ø 4.1

Ø 4.3

Ø 5.0

102.060

102.063

102.066

102.061

102.064

102.067

102.062

102.065

102.068

2 mm 3 mm 4 mm

Page 76: Neodent Product Catalogue - 2013

7878

Internal interface that provides

greater stability and resistance

between implant and Abutment.

Internal Hex

Page 77: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

79

Prosthetic Abutment with reduced platform in relation to implant (Switching Platform).

Cervicalmicro-retentions.

Abutment Indication Table

79

INTERNALHEX

Inne

r Thr

ead

Ø 1.

6

:: II Plus Mini Conical Abutment (multiple)

:: II Plus CoCr UCLA (single):: II Plus Conical Abutment

(single):: II Plus Angled Conical

Abutment (multiple)

:: II Plus Universal Post:: II Plus Angled Post 17°

and 30°:: II Plus CoCr UCLA (single):: II Plus Titanium UCLA (single)

:: II Plus Mini Ball Attachment :: II Plus Angled Conical Abutment:: II Plus Mini Conical Abutment:: Cylinder and Distal Ext. Bar

Passive Fitting Technique:: Castable Cylinder Mini Conical Abut.:: Titanium Cylinder Mini Conical Abut.:: Brass Cylinder Mini Conical Abut.

3.75, 4.3 and 5.0 mm

4.3 and 5.0 mm

Implant Diameter

ProstheticPlatform Diameter

Screw Retained Prosthesis

CementedProsthesis Overdenture Protocol

Implant Diameter

2.5 mm

INTERNAL HEX

2.6 mm

:: Prosthetic Abutments with reduced platform in relation to

implant (Switching Platform);

:: Clip Driver to increase safety when transporting and

installing the implant;

:: Cervical micro-retentions for bone tissue maintenance;

:: Single prosthetic sequence, regardless of implant platform

diameter.

Ø 5.0

Ø 3.8

Internal HexImplantsIIPlus

Page 78: Neodent Product Catalogue - 2013

80

PRODUCTFEATURES:

TitamaxIIPlus

:: Cylinder body implant with internal hex interface;

:: NeoPoros Surface;

:: Instalation is performed with II Plus Drivers (see page 160),

allowing the implant capture directly from the package,

offering greater safety and speed;

:: Dual thread (faster Instalation with less trauma);

:: High cutting power;

:: Recommended for bone types I and II and block grafting areas;

:: Cover screw not included;

:: Single prosthetic interface for all implant diameters;

:: Drilling rotation: 800 - 1200 rpm;

:: Instalation rotation: 30 rpm.

DRILL SEQUENCETitamax

2.0Pilot

3/3.75Starter Pilot

2/3Countersink

II 4.3Countersink

II 5.0Titamax

3.0Titamax

3.15Titamax

3.8Titamax

4.3

3.75mm

5.0mm

*Optional

Cortical

NEW APEXSeamless adaptation between drill and cortical implant

Page 79: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

81

11.0 mm9.0 mm7.0 mm 13.0 mm 15.0 mm

Ø 3.75

Ø 5.0

109.462 109.463 109.464 109.465 109.466

109.474 109.475 109.476 109.477

Platform(4.3)

Cover screw

117.014

:: Use a 1.2 mm Digital Driver (104.007) to install the

cover screw;

:: Do not exceed 10N.cm torque.

Healings

4.0 mm3.0 mm2.0 mm

106.176 106.177 106.178

Page 80: Neodent Product Catalogue - 2013

82

AlvimIIPlus

DRILL SEQUENCEAlvim2.0

Alvim5.0

Starter Alvim3.5

Countersink II 5.0

Alvim4.3

CountersinkII 4.3

4.3mm

5.0mm

PRODUCTFEATURES:

:: Conical body implant with internal hex interface;

:: NeoPoros Surface;

:: Instalation is performed with IIPlus Drivers (see page 160), allowing the

implant capture directly from the package, offering greater safety and

speed;

:: Recommended for type III and IV bones and post-extraction;

:: Cover screw not included;

:: Single prosthetic interface for all implant diameters;

:: Drilling rotation: 500 - 800 rpm;

:: Instalation rotation: 30 rpm.

*Optional

Page 81: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

83

Ø 4.3

Ø 5.0

10.0 mm 13.0 mm 16.0 mm

109.478 109.479 109.480

109.481 109.482 109.483

Cover screw

117.014

:: Use a 1.2 mm Digital Driver (104.007) to install the

cover screw;

:: Do not exceed 10N.cm torque.

Healings

4.0 mm3.0 mm2.0 mm

106.176 106.177 106.178

Page 82: Neodent Product Catalogue - 2013

84

II Plus Conical Abutment II Plus Angled Conical Abutment

Demonstration sequence for

:: Minimum interocclusal space of 6.1mm for the Straight Abutment, and 7.6 mm for the Angled Abutment from

the mucous level; :: Screw retained prosthesis; :: Single Abutment for different II PLUS implant diameters (Ø 3.75,

Ø 4.3 and Ø 5.0); Consider an additional 1.5 - 2.0mm of restoring material.

II Plus Conical Abutment (anti-rotational)

II Plus AngledConical Abutment

(Rotational)

20N.cm

10N.cm

Connection for1.2 Torque

Connection forProsthetic Abutments

Connection for1.6 mm Torque

Conical AbutmentAnalog

Conical AbutmentProtection Cylinder

Ope

n Tr

ay

Clos

ed T

ray

Conical AbutmentTransfer

Conical AbutmentCylinder

CoCr

Cas

tabl

e

Tita

nium

TorqueRatchet

TorqueRatchet

Page 83: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

85

II Plus Conical Abutment:: Please note recommended torque and sequence;:: Single prosthesis (anti-rotational).

1.0 mm 2.0 mm 3.0 mm

115.184 115.185 115.186

II Plus Angled ConicalAbutment 17°:: Please note recommended torque and sequence;:: Multiple Prosthesis (Rotational).

2.0 mm 3.0 mm 4.0 mm

115.203 115.204 115.205

Conical Abutment Transfer

108.035

108.020

108.075

108.018

Open Tray

Closed Tray

Anti-

rota

tiona

lRo

tatio

nal

Ø 4.1

II Plus Conical Abutment Cylinder:: Available in:

Titanium: for provisional prosthesis;CoCr: Overcasting;Castable: For Casting

:: NeoTorque screw included.

CastableAn

ti-ro

tatio

nal

Rota

tiona

lTitanium CoCr

Ø 4.1

118.106

118.104

118.107

118.105

118.233

118.232

Conical Abutment Analog 101.027Ø 4.1

Conical Abutment Protection Cylinder 106.051Ø 4.1

Titanium Neotorque

116.004 116.231

Conical AbutmentCylinder Screw:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use TorqueRatchet (104.050).

Neotorque:: Application of a fine carbon-based coatthat provides a lower friction coefficient,resulting in increased pre-load.

Page 84: Neodent Product Catalogue - 2013

86

II Plus Mini Conical AbutmentDemonstration sequence for

:: Minimum interocclusal space of 4.4 mm from mucous level; :: Multiple (rotational) screw

retained prosthesis; :: Single Abutment for different II PLUS implant diameters (Ø 3.75, Ø 4.3 and

Ø 5.0); :: Consider additional 1.5 - 2.0mm of restoring material.

Connection for1.2mm Torque

Connection forProsthetic Abutments

Ope

n Tr

ay

Clos

ed T

ray

Mini ConicalAbutment Transfer

Mini ConicalAbutment Analog

Mini Conical AbutmentProtection Cylinder

Mini Conical AbutmentCylinder

CoCr

Cas

tabl

e

Tita

nium

TorqueRatchet

II Plus MiniConical Abutment

20N.cm

10N.cm

TorqueRatchet

Page 85: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

87

II Plus MiniConical Abutment:: Please note recommended torque and sequence. 115.155

1 mm 2 mm

115.156 115.157 115.158

3 mm 4 mm

:: Available in Titanium;:: Rotational.

Mini ConicalAbutment Transfer

116.036

Ø 4.1 108.022 108.068

Open Tray

Short Screw

Multifunctional

108.021

Closed Tray

Mini ConicalAbutment Cylinder:: Available in:

Titanium: Provisional Prosthesis;CoCr: OvecastingCastable: For Casting;Noble: Ovecastingwith high melting point alloys.

:: NeoTorque screw included(except for Castable cylinder);:: Rotational for multiple screwretained elements.

118.112 118.113

Castable Titanium

118.206 118.209 118.210

Noble CoCr Welding CoCr

Ø 4.1

Mini ConicalAbutment Analog Ø 4.1 101.020

Mini Conical Abutment Cylinder Screw:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use TorqueRatchet (104.050).

Neotorque:: Application of a fine carbon-based coatthat provides a lower friction coefficient,resulting in increased pre-load.

Ø 4.1

Titanium

116.037 116.227

Neotorque

Mini Conical AbutmentProtection Cylinder Ø 4.1 106.054

Page 86: Neodent Product Catalogue - 2013

88

II Plus Universal PostDemonstration sequence for

:: Cemented prosthesis; :: The Universal Post may be modified as needed, and in this case, the prosthetic

sequence cannot be used; :: Single Abutment for different II PLUS implant diameters (Ø 3.75, Ø 4.3 and Ø 5.0);

:: Screw not included, for single elements select a Neotorque Screw.

II Plus UniversalPost

20N.cm

TorqueRatchet

NeotorqueScrew

Connection for1.2 Torque

PostTransfer 4.5

PostAnalog 4.5

Universal PostCylinder 4.5

Alu

min

a

Cas

tabl

e

Prov

isio

nal

Page 87: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

89

II PlusHex Screw

:: Please note recommended torque and sequence.

:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

Neotorque:: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

Titanium

116.226116.224

Neotorque

Universal Post1 mm

4 m

m

2 mm

6 m

m

Ø4.5

3 mm

114.123 114.124 114.125

114.126 114.127 114.128

:: Available in polymer;:: Abutment with Castable function to pHandleuce the prosthesis;:: For closed Tray technique (replacement);:: Select Transfer according to the Abutmentto be Cast according to prosthetic planning;:: Anti-rotational.

UniversalPost Transfer

4 m

m6

mm

Ø 4.5

108.045

108.044

UniversalPost Analog

4 m

m6

mm

Ø 4.5

101.041

101.040

4 m

m6

mm

Ø 4.5

108.063

108.062

UniversalPost Pack:: Universal Post Pack, includesTransfer, Castable andProvisional Cylinders.

:: Available in:Acrylic: For provisional prosthesis;Alumina: For metal-free prosthesis;Castable.

:: Compatible with all Universal Posts, when not modfied.

UniversalPost Cylinder

4 m

m6

mm

Ø 4.5

118.188 118.183 118.194

118.189 118.184 118.195

ProvisionalAlumina Castable

Page 88: Neodent Product Catalogue - 2013

90

II Plus Angled PostDemonstration sequence for

:: Cemented prosthesis; :: Provides 6 fitting positions; :: Titanium screw included.

II Plus AngledPost

II Plus Analog

Ope

n Tr

ay

Clos

ed T

ray

I I Plus Transfer

Connection for1.2mm Torque

20N.cm

TorqueRatchet

Page 89: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

91

II Plus Angled Post

:: Please note recommended torque and sequence;:: Anti-rotational.

2 mm 3 mm 4 mm

114.171 114.172 114.173170

114.174 114.175300

Ø 4.3

Ø 5.0

101.032

101.034:: Available in brass.

II Plus ImplantAnalog

Implant Transfer

Anti-

rota

tiona

l

108.046 108.047

Open TrayClosed Tray

Page 90: Neodent Product Catalogue - 2013

92

II Plus UCLADemonstration sequence for

:: Cemented or screw retained prosthesis;

:: Presentation:

- CoCr: Over Castable;

- Titanium: Cemented or provisional prosthesis.

:: Screw not included;

:: For single elements, select a Neotorque screw.

20N.cm

II Plus UCLA

II Plus Analog

Ope

n Tr

ay

Clos

ed T

ray

I I Plus Transfer

Connection for1.2mm Torque

CoCr

Tita

nium

NeotorqueScrew

TorqueRatchet

Page 91: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

93

II Plus UCLA

Anti-

rota

tiona

lRo

tatio

nal

118.214

118.213

Cocr

118.185

Titanium

II PlusHex Screw:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use TorqueRatchet (104.050).

Neotorque:: Application of a fine carbon-based coatthat provides a lower friction coefficient,resulting in increased pre-load.

Titanium

116.226116.224

Neotorque

Closed Tray

108.046 108.047

Open Tray:: Available in Titanium.

Implant Transfer

Ø 4.3

Ø 5.0

101.032

101.034

II Plus ImplantAnalog

:: Available in brass.

Page 92: Neodent Product Catalogue - 2013

94

:: Recommended in-mouth capture, one Abutment at a time;

:: Use of positioner is mandatory for capturing;

:: Refer to demonstration sequence on page 142.

Protection Disc Positioner

II Plus Mini BallAttachment

Demonstration sequence for

Connection forProsthetic Abutments

straight 7º 14º

O’ring withCylinder

ProtectionDisc

II Plus MiniBall Attachment

Positioners

20N.cm

TorqueRatchet

Page 93: Neodent Product Catalogue - 2013

I n t e r n a l

H e x

95

CastableBall Attachment

:: Castable polymer;:: May be cemented on natural roots or waxed onto overdentures retaining bars.

102.078

Positioners:: Refer to sequence on page 142. straight , 70 e 140

102.076

Protection Disc:: Package with 10 units.

102.077

O’ring with cylinder:: Protection Disc included;:: Titanium cylider and polymer O’ring

102.073

Pink O’ring:: Available in polymer. 102.075

O’ringremover:: Digital Driver to remove the O’ring from the cylinder.

104.044

O’ringassembler:: Digital Driver to replace the O’ring on the cylinder.

104.043

II Plus MiniBall Attachment:: For Instalation, use a Prosthetic AbutmentConnection (105.009);:: Please note recommended torque;:: For torque control, use TorqueRatchet (104.050).

102.090 102.091 102.092

2 mm

Ø 4.1

3 mm 4 mm

Page 94: Neodent Product Catalogue - 2013

96

Neodent short implants (WS line) have a wide

diameter and are the best prescription for upper and

lower posterior regions.

WSMorse Taper

96

Page 95: Neodent Product Catalogue - 2013

97

IMplante WS

ImplantsWS

Abutment Indication Table

•WS Abutment (single)•Mini WS Conical Abutment

(multiple)•CM Transepithelial Abutment(multiple)

•WS Universal Post with Screw

•Mini WS Abutment

Passive Fitting Technique•Castable Cylinder Mini Conical Abut.•Titanium Cylinder Mini Conical Abut.•Brass Cylinder Mini Conical Abut.

WS MORSE TAPER AND ZYGOMATIC

4.0, 5.0 and 6.0 mm

Screw Retained Prosthesis

Cemented Prosthesis Overdenture Protocol

Ø 3.0 mm

Ø Implant

MORSE TAPER

Inne

r Thr

ead

Ø 1.

8

97

Page 96: Neodent Product Catalogue - 2013

98

PRODUCTFEATURES:

TitamaxWS

DRILL SEQUENCETitamax

2.0Starter Pilot

2/3Titamax

3.3Pilot CM3.3 / 4.0

Pilot CM4.3 / 5.0

Pilot CM3.8 / 4.3

Titamax5.3

Titamax4.3

Pilot CM5.3 / 6.0

Titamax3.0

Pilot CM3 / 3.75

Titamax3.8

Pilot CM4.3 / 5.3

4.0mm

5.0mm

6.0mm

*Mandatory for Cortical Implant andoptional for Medular Implant

:: Cylinder body implant with Morse Taper interface;

:: NeoPoros Surface;

:: Pre-assembled;

:: Cover screw not included;

:: Primary stability optimization;

:: Excelent alternative for upper and lower posterior free

extremity;

:: Pre-assembled;

:: Please note the specific Pilot Drill (countersink function);

:: For the WS Medular Titamax Implant, a pilot drill is optional;

:: Drilling rotation: 200 to 300 rpm;

:: Insertion rotation: 30 rpm;

:: Exclusive Morse Taper prosthetic interface (samesize as CM Zygomatic Implants).

Page 97: Neodent Product Catalogue - 2013

I m p l a n t s

W S

99

5.0 mm 5.0 mm6.0 mm 6.0 mm

Ø 4.0 Ø 4.0

Ø 5.0 Ø 5.0

Ø 6.0

109.604 109.578109.605 109.579

109.574 109.580109.575 109.581

109.576 109.577

WS Healings

3.5 mm2.5 mm1.5 mm0.8 mm

106.186 106.187 106.188 106.189

Cortical Medular

117.016

WSCover Screw

:: Use 1.2 mm Digital Driver (104.007) to install

the cover screw;

:: Do not exceed 10N.cm torque.

Page 98: Neodent Product Catalogue - 2013

100

:: Minimum interocclusal space of 5.0mm from mucous level; :: Single prosthesis screw retained

(Anti-rotation); :: Recommended for posterior regions; :: Consider additional 1.5 - 2.0mm of

restoring material.

WS AbutmentDemonstration sequence for

32N.cm

Connection for1.6 torque

CM Abutment Analog

CM AbutmentProtection Cylinder

TorqueRatchet

CM AbutmentCylinder

Connection for1.2mm torque

10N.cm

CoCr

Cas

tabl

e

Tita

nium

CM AbutmentTransfer

Ope

n Tr

ay

Clos

ed T

ray

WS Abutment

TorqueRatchet

Page 99: Neodent Product Catalogue - 2013

I m p l a n t s

W S

101

CM Abutment Transfer

108.039

Open Tray

Closed Tray

108.040

:: Available in Titanium;:: Anti-rotational.

CM Abutment Cylinder

CM Abutment Analog

:: Available:Titanium: For prosionary prothesis;CoCr: OverCasting;Castable: For casting.

:: Screw Included;:: Anti-rotational.

Castable

Titanium

CoCr

118.180

118.179

118.242

101.037

106.102CM AbutmentProtection Cylinder

CM AbutmentCylinder Screw

Titanium Neotorque

116.038 116.228:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050);

Neotorque :: Application of a fine carbon-based coatthat provides a lower friction coefficient, resultingin increased pre-load.

WS Abutment:: Please note corresponding sequence andrecommended torque.

0.8 mm 1.5 mm 2.5 mm 3.5 mm

115.180 115.181 115.182 115.183

Page 100: Neodent Product Catalogue - 2013

102

:: Minimum interocclusal space of 4.4 mm from mucous level; :: Multiple screw retained prosthesis;

:: Consider additional 1.5 - 2.0mm of restoring material.

WS Mini Conical AbutmentDemonstration sequence for

Connection forProsthetic Abutments

TorqueRatchet

Mini ConicalAbutment Analog

Mini Conical AbutmentProtection Cylinder

Connection for1.2mm Torque

32N.cm

Mini ConicalAbutment Cylinder

10N.cm

Cas

tabl

e

Tita

nium

CoCr

/ N

oble

WS MiniConical

Abutment

Mini ConicalAbutment Transfer

Ope

n Tr

ay

Clos

ed T

ray

TorqueRatchet

Page 101: Neodent Product Catalogue - 2013

I m p l a n t s

W S

103

Mini ConicalAbutment Transfer:: Available in Titanium;:: Rotational.

116.036

Ø 4.1 108.022 108.068

Open Tray

Short Screw

Multifunctional

108.021

Closed Tray

Mini ConicalAbutment Cylinder:: Available in:

Titanium: Provisional Prosthesis;CoCr: Overcasting;Castable: For Casting;Noble: Noble alloy with highmelting point.

:: Screw included;:: Rotational for multiple screwretained elements.

Castable Titanium Noble CoCr Welding CoCr

118.112Ø 4.1 118.113 118.206 118.209 118.210

Mini ConicalAbutment Analog Ø 4.1 101.020

Mini Conical AbutmentProtection Cylinder Ø 4.1 106.054

WS Mini Conical AbutmentCylinder Screw

Titanium Neotorque

116.037 116.227:: Please note recommended torque; :: Use 1.2mm torque connection (105.005);:: For torque control, use TorqueRatchet (104.050);

Neotorque :: Application of a fine carbon-based coatthat provides a lower friction coefficient, resultingin increased pre-load.

WS Mini Conical Abutment

115.176 115.177 115.178 115.179

0.8 mm 1.5 mm 2.5 mm 3.5 mm:: Please note recommended torque and sequence.

Page 102: Neodent Product Catalogue - 2013

104

:: Cemented prosthesis.

WS Universal PostDemonstration sequence for

Optional Sequence

WS ImplantTransfer

Closed Tray

WS ImplantAnalog

WS Post

Lab Stage

Connection for1.2mm torque

TorqueRatchet

TorqueRatchet

CM PostTransfer 4.5

Universal PostCylinder 4.5

CM PostAnalog 4.5

Connection for1.2mm torque

WS Post

Prosthesis Completed

Alu

min

a

Cas

tabl

e

15N.cm

32N.cm

Prov

isio

nal

Recommended sequence

Page 103: Neodent Product Catalogue - 2013

I m p l a n t s

W S

105

WS Universal Post

WS Implant Transfer

WS Analog

UniversalPost Transfer

:: In two parts (body and screw);:: Please note recommended torque and sequence. 114.183 114.184 114.185 114.186

114.187 114.188 114.189 114.190

0.8 mm

Ø 4.5 4 m

m6

mm

1.5 mm 2.5 mm 3.5 mm

:: Available in Titanium.108.064

101.055

:: Available in polymer;:: Abutment with impression function topHandleuce the prosthesis;:: For closed Tray technique (replacement);:: Select Transfer according to theAbutment to be Cast according toprosthetic planning;:: Anti-rotational.

108.044

108.045

Ø 4.5

4 m

m6

mm

UniversalPost Cylinder:: Available in:

Acrylic: For provisional prosthesis;Alumina: For metal-free prosthesis;Castable: For Casting.

:: Compatible with all Universal Posts,when modified.

118.188 118.183 118.194

118.189 118.184 118.195

ProvisionalAlumina Castable

Ø 4.5

4 m

m6

mm

Universal PostPack

Universal PostAnalog

:: Universal Post Pack, including Transfer, Castableand Provisional Cylinders.

108.062

108.063

Ø 4.5

4 m

m6

mm

Ø 4.5

4 m

m6

mm

101.040

101.041

Page 104: Neodent Product Catalogue - 2013

106

ZygomaticCM and HE

106

Page 105: Neodent Product Catalogue - 2013

I m p l a n t s

Z y g o m a t i c

107

ImplantsZygomatic

107

Hex 2.7 mm

Ø 4.1 mm

0.7 mm

ø 3.0 mm

Page 106: Neodent Product Catalogue - 2013

108Note: This technique requires specific accreditation.

Information through +55 41 2169 1030

PRODUCTFEATURES:

:: Cylinder Implant;

:: Clean surface;

:: Pre-assembled;

:: Cover screw not included;

:: Dual thread in CM Zygomatic version;

:: The use of the Transepithelial Abutment is recommended for

the prosthetic interface;

:: Exclusive Morse Taper prosthetic interface (samesize as WS Implants).

Ø 4.4mm

Leng

th

Ø 3.9mm

ImplantsZygomatic

Page 107: Neodent Product Catalogue - 2013

I m p l a n t s

Z y g o m a t i c

109

CM ZygomaticCover screw:: Use 1.2 mm Digital Driver (104.007)to install the cover screw;:: Do not exceed 10N.cm torque.

30.0 mm 35.0 mm 40.0 mm 45.0 mm 47.5 mm 50.0 mm 52.5 mm

109.522 109.523 109.524 109.525 109.526 109.527 109.528

Morse Taper

30.0 mm 35.0 mm 40.0 mm 45.0 mm 47.5 mm 50.0 mm 52.5 mm

109.460 109.450 109.451 109.452 109.461 109.453 109.454

External Hex

117.016

External HexCover Screw:: Use 0.9 mm Digital Driver (104.039)to install the cover screw;:: Do not exceed 10N.cm torque.

117.018

Page 108: Neodent Product Catalogue - 2013

110

Transepithelial AbutmentDemonstration sequence for

:: Mini interocclusal space of 4.5mm; :: Multiple retained prothesis; :: Morse taper abutment

compatible with Titamax WS Implant.

Transepitelial AbutmentProtection Cylinder

TransepitelialAbutment Analog

TransepitelialAbutment Cylinder

TransepitelialAbutment Transfer

Open Tray

Connection for1.2mm Torque

Connection forProsthetic Abutments

Cas

tabl

e

CoCr

TransepithelialAbutment

32N.cm

20N.cm

10N.cm

Exte

rnal

Hex

Mor

se T

aper

TorqueRatchet

TorqueRatchet

Page 109: Neodent Product Catalogue - 2013

I m p l a n t s

Z y g o m a t i c

111

:: For Instalation, use a Prosthetic Abutment Connection (105.009);:: For torque control, use Torque Ratchet (104.050).

External HexTransepithelial Abutment

Morse TaperTransepithelial Abutment

115.023 115.024 115.025

3 mm 4 mm 5 mm

115.172 115.173 115.174

3 mm 4 mm 5 mm

108.026

101.018

106.056

TransepithelialAbutment Transfer:: Disponível em Titanium;:: Rotational.

Transepithelial Abutment Cylinder:: Available in:

Castable: For Casting;CoCr: Overcasting in several metals.

:: Screw included.

Castable CoCr

118.034 118.254

TransepithelialAbutment Analog

TransepithelialAbutment Protection Cylinder

Cylinder Screw:: Please note recommended torque;:: Use 1.2mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

Neotorque:: Application of a fine carbon-based coat that provides a lower friction coefficient, resulting in increased pre-load.

Titanium

116.004 116.231

Neotorque

Page 110: Neodent Product Catalogue - 2013

112112

Page 111: Neodent Product Catalogue - 2013

I m p l a n t s

Z y g o m a t i c

113113

Orthodontic Anchoring

BoneGrafting

Page 112: Neodent Product Catalogue - 2013

114

PRODUCTFEATURES:

Orthodontic Anchoring

:: Available in Titanium alloy as per ASTM-F136 ( V);

:: Implants for orthodontic movement;

:: Self-perforating;

:: Collar height:

- Low: 0 mm;

- Medium: 1 mm.

:: Torque resistance of up to 10 N.cm (Ø 1.3 mm) and 20 N.cm

(Ø 1.6 mm).

Hex Size: 2.7 mm

Hole Diameter:

0.7mm

1 m

m

Orthodontic Anchoring Implant Package. Removing the cap to access the implant.

1 2

Page 113: Neodent Product Catalogue - 2013

115

O r t h o d o n t i c

A n c h o r i n g

9 mm

9 mm

7 mm

7 mm

5 mm

5 mm

11 mm

11 mm

Ø 1.3

Ø 1.3

Ø 1.6

Ø 1.6

109.484

109.487

109.485

109.488

109.486

109.489

109.701

109.702

109.493

109.496

109.494

109.497

109.495

109.498

Low Collar

Medium Collar

Implant capture with Orthodontic

Anchoring Contra-Angle Connection.

Implant Instalation with Contra-Angle

Connections (105.039 or 105.040).

Option of manual implant insertion using

Tuff Driver (104.033) or Ratchet and Ratchet

Adapter for Contra-Angle Connections

(105.025).

Implant installed.

3 4 5 6

Page 114: Neodent Product Catalogue - 2013

116

PRODUCTFEATURES:

BoneGrafting

:: Available in Titanium;

:: Fixation of bone block;

:: Self-perforating.

Expanded Head

Standard Head

Ø 2.0 mm Ø 3.0 mmØ 3.85 mm

Ø 1.5 mm Ø 2.5 mmØ 3.70mm

Page 115: Neodent Product Catalogue - 2013

117

B o n e

G r a f t i n g

10 mm8 mm6 mm 12 mm 14 mm

Ø 1.5

Ø 2.0

116.196116.194 116.198 116.199 116.200

116.203 116.205 116.207 116.209

10 mm8 mm 12 mm 14 mm

Ø 1.5

Ø 2.0

116.210 116.211 116.212 116.213

116.214 116.215 116.216

Standard Head

Expanded Head

Page 116: Neodent Product Catalogue - 2013

118

BONE GRAFTINGAND ORTHODONTIC

ANCHORING KITFEATURES:

:: Autoclavable polymer case

Note: Items that compose Neodent Kits are sold separately.

Page 117: Neodent Product Catalogue - 2013

119

B o n e

G r a f t i n g

Contents

Bone Grafting and Orthodontic Anchoring CaseBone Grafting Manual DriverPhilips Connection for Manual DriverPhilips Connection for Contra-AngleDrill 1.6 for Contra-AngleDrill 1.3 for Contra-AngleDrill 1.1 for Contra-AngleDrill 1.6 for Straight PieceDrill 1.3 for Straight PieceDrill 1.1 for Straight PieceBone Grafting and Orthodontic Anchoring PunctureAnchoring Tuff DriverAnchoring Contra-Angle Connection - LongAnchoring Contra-Angle Connection - ShortRatchet Adapter for Contra-Angle Connections

110.227104.018105.063105.023103.045103.079103.044103.043103.078103.042103.207104.033105.039105.040105.025

111111111111111

Bone Grafting andOrthodontic AnchoringKit

XXXXXXXXXXX

XXXXXXXXXXXXXXX

X

XX

XX

XXXX

Graf

ting

Com

plet

e

Anch

orin

g

Page 118: Neodent Product Catalogue - 2013

120

Bone Grafting and Orthodontic Anchoring Puncture 103.207

:: Available in stainless steel;:: Initial cortical rupture.

Drills forOrthodontic Anchoring:: Available in surgical steel;:: Recommended for type I and II bones;:: Marks refer to Implant length (5, 7, 9 and 11mm).

7 mm5 mm

9 mm11 mm

103.042 103.078 103.043

103.044

Ø 1.1mm Ø 1.3mm Ø 1.6mm

Straight Piece

Contra-Angle 103.079 103.045

105.040

Short

105.039

Long

105.025Orthodontic AnchoringAdapter Connections:: Connections for installing Anchoring Implants with Ratchet and Contra-Angle;

:: Ratchet Adapter for Contra-Angle Connections (105.025).

Page 119: Neodent Product Catalogue - 2013

121

B o n e

G r a f t i n g

Orthodontic AnchoringTuff Driver

Manual Driver

:: Available in stainless steel;:: Orthodontic Anchoring Implant manual Instalation.

104.033

104.018:: Assists in handling Philips Driver (105.063) and the Puncture for Bone Grafting andOrthodontic Anchoring Guide (103.207).

Philips Driver

105.063

Manual Driver

105.023

Contra-Angle:: Available in stainless steel;:: Screw Instalation for bone grafting.

Page 120: Neodent Product Catalogue - 2013

122122

Page 121: Neodent Product Catalogue - 2013

N e o d e n t

Te c h n i q u e s

123

NeodentTechniques

123

Page 122: Neodent Product Catalogue - 2013

124

Contents

127.027127.028127.029127.030127.032127.031104.048103.356103.357

111111111

Tooth Extractor (with case)Tooth Extractor Tractor ø 2.10x10mmTooth Extractor Tractor ø 1.60x16mmTooth Extractor Tractor ø 1.60x10mmTooth Extractor Tractor ø 2.10x16mmTooth Extractor Wire RopeTooth Extractor Digital DriverTwister Drill for Extractor 1.30mmTwister Drill for Extractor 1.80mm

BENEFITS

HOW DOES IT WORK?

:: Preservation of bone bed and adjacent tissues;

:: Reduced surgery time;

:: Practical and streamlined handling;

:: Greater procedure safety and stability.

To perform a radicular extraction, you only need to turn the

handle, making the wire rope attached to the tractor to

remove the root, while preserving adjacent structures.

Note: Items that compose the Tooth Extractor Kit are also sold separately.

127.038Extractor Tray

Page 123: Neodent Product Catalogue - 2013

N e o d e n t

K i t s

125

Tooth Extractor

Fitting the Tray to the Tooth Extractor.

Root removal by rotating the handle clockwise.

DEMONSTRATION SEQUENCE

TOOTH EXTRACTOR KITFEATURES

The Tooth Extractor provides practical and efficient

handling. It is a solution that brings comfort, ease

and precision to your practice.

With simple and quick operation, the extractor

allows extraction with less trauma in comparison

with conventional techniques, preserving bone

integrity in a safer surgical procedure.

Residual tooth root preparation.Tray preparation (127.038), Tray sold separately.

Syndesmotomy.

Instalation of Tractor to prepared area with Digital Driver.

1 2

5

3

64

Page 124: Neodent Product Catalogue - 2013

126

GUIDED SURGERY INA SIMPLE, PRACTICALAND ACCURATE WAY

NeoGuide has improved into a simplified service that helps you over essential stages of guided surgery, streamlining planning and providing better surgical and prosthetic predictability.With only 3 steps, we deliver to you a more accessible protocol:

Step 1:You send the tomography files from your patient to the NeoGuide Technology Center, where a team of professors will work in virtually placing implants and prosthetic abutments to develop a surgical guide.

Step 2:You receive the virtual project by e-mail and, comfortably at home, your office or elsewhere, you approve the planning or suggest adjustments you consider necessary.

Step 3:We deliver a surgical guide, just as you need it. With NeoGuide, the result is a quick and accurate treatment, valuing your time, work quality, and your patients’ comfort and safety.

// Flapless surgery with reduced surgical trauma.// Guided implants from beginning to end.// Easy Instalation of prosthetic abutments// Prosthetic abutment system that allow passive prosthesis fitting.// Possibility of pHandleucing the prosthesis before the surgery.// Reduced surgery time.// Support and guidance for best technique.

NEOGUIDE ADVANTAGES:

HELPING YOU IN ESSENTIAL STAGES

126

Page 125: Neodent Product Catalogue - 2013

127

UNDERSTANDING HOWNEOGUIDE WORKS

Tomographic GuideIt is used to simulate the desired teeth position.

Ideally, this guide is obtained by duplicating the wax teeth

assembly.

Surgical Guide ProductionUsing state-of-the-art machinery, guides are pHandleuced

with high accuracy and quality controle, using industry

standards.

Virtual Positioning

The NeoGuide Center optimally positions implants,

searching for the ideal location, and sends it back to the

professional.

TomographyScanning is to obtain images of bone density,

alveolar flap outlines and tomographic guide

imaging.

Guided SurgeryWith streamlined NeoGuide Kits, the work becomes of

confidence and precision for flapless surgery.

Planning Approval

Using the free NeoGuide Light software, the

professional reviews and approves the planning

provided by the Neodent team.

01

05

0302

06

04

127

Page 126: Neodent Product Catalogue - 2013

128

Note: Items that compose Neodent Kits are sold separately.

NEOGUIDE KITFEATURES:

:: Technique-specific composition;

:: Autoclavable polymer case

:: Drivers, connections and surgery Instruments needed for

the NeoGuide technique;

:: Recommended technique for virtual planning and

flapless surgery.

Page 127: Neodent Product Catalogue - 2013

I m p l a n t s

Z y g o m a t i c

129

Contents

Neoguide Surgical Kit CaseNeoguide Contra-Angle Mucous ExtractorNeoguide Manual Mucous ExtractorNeoguide Drill 1.3Neoguide Drill 2.0Neoguide Drill 2.8Neoguide Drill 3.0Neoguide Drill 3.3Neoguide Pilot Drill 3.5Neoguide Pilot Drill 3.75Neoguide Pilot Drill 4.0Neoguide Contra-Angle Narrow Mucous ExtractorNeoguide Manual Narrow Mucous ExtractorNeoguide Narrow Pilot DrillNeoguide CM 3.5 Contra-Angle ConnectionNeoguide CM 3.75 Contra-Angle ConnectionNeoguide CM 4.0 Contra-Angle ConnectionRatchet Hex ConnectionNeoguide CM Narrow Contra-Angle ConnectionNeoguide CM Narrow Ratchet ConnectionShort 1.2 Digital DriverDigital Driver for Torque ConnectionsNeoguide Drill Guide 2.0Neoguide Drill Guide 2.8Neoguide Drill Guide 3.0Neoguide Drill Guide 3.3Neoguide Guide FastenerNeoguide Narrow Drill Guide 2.0Neoguide Narrow Drill Guide 2.8Neoguide Guide StabilizerNeoguide Narrow Guide StabilizerTorque RatchetTitanium TweezersNeoguide Implant Guide 3.5Neoguide Implant Guide 3.75Neoguide Implant Guide 4.0

110.250 103.180 103.181 103.179 103.183 103.184 103.185 103.186 103.187 103.188 103.189103.194103.195103.196 105.079105.080105.081105.001105.091105.092104.007104.005 125.033 125.034 125.035 125.036 125.032125.039125.040 125.041125.059104.050129.001125.029125.030125.031

111111111111111111111111114114211555

XXXXXXXXXXX

XXXX

XXXXXXX

X

XXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

Regu

lar

Com

plet

e

Page 128: Neodent Product Catalogue - 2013

130

Neoguide Drills:: Available in surgical steel;:: Twister Drill for ø1.3 and ø 2.0 and Tri-spade for other diameters;:: 1.3 drill for drilling through Surgical Guide tubes;:: Marks from 7 to 17mm.

PLUS DRILLS: Application of a fine carbon-based coat that reduces the friction coefficient and the heat generated during osteotomy.

103.179 103.183 103.184 103.185 103.186

Ø1.3 Ø2.0 Ø2.8 Ø3.0 Ø3.3

125.029 125.030 125.031

Ø3.5 Ø3.75 Ø4.0

125.032Guide Fastener

:: Available in Titanium;:: Pin that fastens the prototype surgical guide over the flap;:: Working length of 12mm and Ø1.3 mm.

Neoguide Pilot Drills

:: Available in surgical steel with carbon coating to provide lower friction coefficients;:: Preparation of bone crest to settle the cervical Bone of Titamax CM Implants;:: Recommended for type I and II bones.

103.187 103.188 103.189

ø3.5 ø3.75 ø4.0

Neoguide Kit

Neoguide KitNarrow

103.196

125.041Neoguide Kit

Neoguide KitNarrow

125.059

:: Available in Titanium;:: Aims to stabilize the prototype guide after the Instalation of each implant.

Stabilizer

Mucous Extractor:: Available in surgical steel with carbon coating to provide lower friction coefficients;:: Guided circle incision for mucous removal;:: Rotating Mucous Extractor - Used with Contra-Angle;:: Manual Mucous Extractor - Used manually with Digital Driver for Torque Connections (104.005);:: Also recommended as a punch.

103.180 103.181

Contra-Angle Manual

Neoguide Kit

Neoguide KitNarrow

103.194 103.195

Neoguide Implant Guide:: Available in Titanium;:: Guide for CM Implant Instalation using Neoguide Technique;:: Colors indicate the CM Implant diameters.

Page 129: Neodent Product Catalogue - 2013

I m p l a n t s

Z y g o m a t i c

131

125.033 125.034 125.035 125.036

ø2.0 ø2.8 ø3.0 ø3.3

Neoguide Kit

Neoguide KitNarrow

125.039 125.040

105.079 105.080 105.081

3.5 3.75 4.0

Neoguide Kit

Neoguide KitNarrow

105.091 125.040

Drill Guide:: Use the drill that matches the Surgical Guide diameter (color-coded);:: Fitted to Surgical Guide ringlets;:: Colors indicate the CM Implant diameters.

Neoguide CMContra-Angle Connection:: Available in Titanium;:: To insert implants using the motor and contra-angle.

:: Available in Titanium;:: Used with Mini Conical Abutment Analog to obtain a working model;:: Includes 3 pieces of 1mm high spacers;:: Technique for pHandleucing the prosthesis before the surgery.

PositionerNeoguide

Ratchet Hex Connection(Ratchet Driver Connection):: Available in surgical steel;:: Adaptation of hex assemblies;:: Fit in square ratchets;:: Silicone ring for better assembly tightening and transport.

105.001

101.054

Page 130: Neodent Product Catalogue - 2013

132

The 3shape scanner is the first step to use the Neoshape system, which has the accuracy of laser scanning as one of its highlights. With it, a Prosthesis Technician can scan impression models or Castables and, through a simple 3D modeling software, create pieces in a simple and intuitive way.Scanners D700, D500 e D810 provide micrometric precision by performing a laser reading on three different axes with no human contact. Professionals that purchase the system are provided with world-class tech support by the company and all technical information for the product to be used properly.

:: NEODENT and 3SHAPE PARTNERSHIP

CAD/CAM System

The Dental Designer software is versatile and intuitive. Its tools are straightforward and allow the handling of prosthetic structure drawings in a quick

and efficient way. It allows customized anatomic adjustments such as: cementing space, coping width, adding or removing

virtual waxing, abutment customization, among many others. As all planning happens virtually, the

waste of time and materials is reduced.

:: DENTAL DESIGNER SOFTWARE

Page 131: Neodent Product Catalogue - 2013

133

The milling process begins after a virtual image (previously designed by the prosthesis technician through the Dental Designer software) is sent to the CAM software, which will mathematically define the angles and axes to be designed on the material in order to reach a result exactly the same as planned.

• micrometric adaptation;• optimization of production time;• automation of manual labor: virtual waxing;• laser scanning technology: accuracy and speed;• 5 axes milling: production faithful to CAD drawing;• raw materials with proven sources and quality.

:: NEODENT MILLING CENTER

:: AVAILABLE MATERIALS:

- Cobalt-Chromium: ideal for metal-ceramic prosthesis.- Titanium: Recommended material for infrastructure in hybrid prosthesis.- Zircon: Aesthetics, high resistance, bio-compatibility.- E-max® CAD: Translucent, resistant, aesthetic, and easy to use.

Digital planning of high complexity dental prosthesis

Page 132: Neodent Product Catalogue - 2013

134

The Neoshape System comprises new industry technologies to ensure the accuracy and quality in pHandleucing several prosthetic techniques available in the marketplace. This news widens horizons, offering excellence, adaptation, precision and aesthetics in a customized way with digital planning.

With that, the prosthesis technician uses the computer screen to plan in three dimensions all aesthetic and functional details of different prosthetic resolutions in common lab tasks.

After the virtual waxing is completed, a digital file is forwarded online to the Neodent Milling Center. There, the information received from each case is managed. Next, the file is forwarded to state-of-the-art equipment that accurately repHandleuce the 3D drawings through milling, ensuring a precise adaptation and finishing.

The Neoshape system offers, along with its 3D modeling software, an extensive library of prosthetic interfaces, allowing the prosthetic to pHandleuce customized structures over any Neodent implant or prosthetic abutment, with the same quality and adaptation accuracy of a standard abutment.

Regardless of the material chosen to pHandleuce the prosthesis, the mechanical properties and quality warranty are reassured by world-class quality and controlled source raw materials, reinforcing our ethical commitment.

2. Scanning

PROSTHESIS TECHNICIANTASK

4. Production of customized part at the Neodent Milling

Center

NEODENT TASK

3. CAD Modeling in 3D planning software

PROSTHESIS TECHNICIANTASK

5. Prosthesis completed with porcelain application

PROSTHESIS TECHNICIANTASK

DENTIST TASK

1. Patient

Page 133: Neodent Product Catalogue - 2013

135

4

Virtual planning.

Castable of the elements to be restored and antagonist arc.

1

For overdenture work, the impression model must be dried and with preparation edges exposed and delimited. For implant works, the model must be hollow, with artificial gums.

2

Scanning the working model and antagonist.

3

STEP BY STEP TECHNIQUE

5

Indutrial milling. Micrometric level quality control.

6

Different technique and material possibilities.

Page 134: Neodent Product Catalogue - 2013

136

Passive FittingDemonstration sequence for

Technique that allows passive Fitting, with no need for welding through cementing the Titanium cylinder to

the metal structure. Used for multiple prostheses and reduces laboratory work times.

Page 135: Neodent Product Catalogue - 2013

N e o d e n t

Te c h n i q u e s

137

Mini Conical Abutment Pas-sive Fitting Cylinders:: Brass and Titanium cylinders include screw;:: For Instalation, use 1.2 mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

118.083

118.089

118.081

118.087

118.082

118.088

Castable

ø4.1

ø5.0

Brass Titanium

118.250 118.248 118.249

Castable Brass Titanium

118.174 118.173 118.172

Castable Brass Titanium

116.086 116.087

4.1 mm 5.0 mm

CM Micro AbutmentPassive Fitting Cylinders:: Brass and Titanium cylinders include screw;:: For Instalation, use 1.2 mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

GT PassiveFitting Cylinders:: Brass and Titanium cylinders include screw;:: For Instalation, use 1.2 mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

Passive FittingWork Screw:: For laboratory use.

118.086 118.084 118.085

Castable Brass TitaniumTransepithelial Abutment Passive Fitting Cylinders:: Brass and Titanium cylinders include screw;:: For Instalation, use 1.2 mm torque connection (105.005);:: For torque control, use Torque Ratchet (104.050).

Page 136: Neodent Product Catalogue - 2013

138

Passive FittingDemonstration sequence for

Normalization of alveolar flaps.

Surgical drilling completed, obtaining

adequate distance from Distal implant in relation

to the mental foramen with 7mm flag.

1 2

Instalation of square transfers, replaced by

short screws (Mini conical Abutment cylinder screw) and transfers joined with

acrylic resin.

Positioning of Multi-functional Guide to

obtain intermaxillary ratios. Joining transfers with acrylic resin. After

joining, liquid silicone is injected for impression of

soft tissues.

5 6

Castable Passive Fitting Cylinder, Brass Passive

Fitting Cylinder, grooved Titanium Passive Fitting

Cylinder with lower dimension than the brass,

which compensates hiring the mill.

9

Instalation of 5 Titamax Cortical CM Implants

Ø3.75.

Instalation of CM Mini Conical Abutments.

3 4

Removal of Multi-Funcional Guide and

Instalation of Mini Conical Abutment analogs to the

transfers.

Working model with artificial gum.

7 8

Page 137: Neodent Product Catalogue - 2013

N e o d e n t

Te c h n i q u e s

139

Castable ring with waxed infrastructure.

Brass Cylinders are placed over analogs, Then Castable Cylinders are fixed by working screws.

1110

Cementing with Panavia® (Kuraray Med. Inc. Tokio-Japan) the structure over the Titanium cylinders.

Please note cementing area.

1514

Adapting the infrastructure over the model.

Fused infrastructure.

1312

Final inside-mouth view.

16

Page 138: Neodent Product Catalogue - 2013

140

Distal BarDemonstration sequence for

:: Technique used to ease mandible rehabilitation, through a provisional protocol-type prosthesis supported

by implants.

Distal Bar:: Recommended for distal Implants to reinforce the Cantilever. 125.011

Mini Abutment GT

Ø 4.1

Ø 5.0 125.012

125.023

:: Available in surgical steel;:: Recommended for Conical Transfer (used in closed tray technique).

Polish protector123.008 123.009

Distal Bar Cylinder:: Available in Titanium;:: Retainers to ease joining with acrylic resin;:: Recommended torque: 10 N.cm;:: For torque, use 1.2mm torque connection (105.005).

118.169

Mini Abutment GT

Ø 4.1

Ø 5.0 118.170

118.171

Page 139: Neodent Product Catalogue - 2013

N e o d e n t

Te c h n i q u e s

141

Prosthesis wearing, keeping posterior region integrity.

GT Implants installed.

21

Applying self-polymerizing acrylic resin on cylinders.

Placement of rubber dike over cylinders to protect soft tissue. 65

Wearing, finishing and polishing inferior prosthesis with polishing protectors.

Removal of inferior prosthesis after resin is polymerized, cylinders already captured.

109

Proof of inferior prosthesis wearing (centered occlusion position, no interference on cylinders).

Instalation of cylinders to central Implants and Distal Bar to posterior Implants.

43

Applying to worn area in lower prosthesis, repositioning inside mouth, patient in occlusion until total polymerization.

Applying acrylic resin between cylinders.

87

Final posterior inside-mouth view.

Provisional implant-supported prosthesis completed. 1211

Page 140: Neodent Product Catalogue - 2013

142

Mini Ball AttachmentDemonstration sequence for

Page 141: Neodent Product Catalogue - 2013

N e o d e n t

Te c h n i q u e s

143

Implants installed.Production of new total prosthesis.

21

Placement of protection discs.

Using positioners to correct paralleling between Implants and determine the right distance between o’ring and Attachment.

65

First O’ring captured.Prosthesis proof to verify adaptation without interference. 109

Ball Attachments installed.

Abutments.

43

Lower view of relief performed.

Placement of o’rings.

87

Side view of assembly.Second o’ring captured.

1211

Page 142: Neodent Product Catalogue - 2013

144144

Page 143: Neodent Product Catalogue - 2013

I m p l a n t s

Z y g o m a t i c

145145

Neodent Kits

STERILIZATIONSterilize on the day before or the day of the procedure. We recommend, preferentially, the sterilization method by steam autoclaving, including the parameters and procedures set forth in regulation BS EN ISO 17665-1: Sterilization of health care products. Moist heat. Requirements for the development, validation and routine control of a sterilization process for medical devices; or to proceed according to the autoclave manufacturer’s instruction manual. WARNING: KITS ARE DAMAGED IF SEALED WITH DUCT TAPE. DO NOT STERILIZE POLYMER PRODUCTS USING STOVE. STERILIZATION PERIOD: 7 to 15 days, if stored in a clean, dry environment protected from sunlight.

CLEANINGNeodent Kits and Surgical Instruments must be properly cleaned after each use. Do not leave them in contact with humidity for long periods. 1st step: Disassemble parts (if applicable). 2nd step: Completely immerse the part in 10% enzymatic detergent solution. 3rd step: Wash in ultrasound cleaner for about 10 minutes. 4th step: Rinse with abundant distilled water to completely remove solution residues, even by brushing, if needed. 5th step: Dry with paper towels or air blower. 6th step: Perform a visual inspection to check for flaws in the cleaning process. If the part is dirty, it should be immersed again in detergent – steps 1 and 2 – and, if needed, clean with a nylon brush (repeat the rinse and dry sequence). 7th step: Select the package according to the sterilization process. Prefer self-sealing packages with surgical paper and film blade. IMPORTANT: Never store the material unless completely dry. Drying is extremely important to prevent oxidation. WARNING: Do not use (non-enzymatic) descaler products, as they tend to darken parts and also cause oxidation. The use of enzymatic fluid in higher concentration than 10%, as well as drying parts that contain residual cleaning solution, favors oxidation and should be avoided.

Surgical Tweezer with automatic implant locking and millimeter scale for reference during procedures.

Surgical and Prosthetic Ratchet (single model) can be disassembled and has torque control.

Paralleling positioners are color-coded and numbered to show the exact implant size to be used.

Page 144: Neodent Product Catalogue - 2013

146

Note: Items that compose the Surgical Kit

are sold separately. Below,

we suggest three Surgical Kit setups:

Starter, Intermediate and Advanced.

Page 145: Neodent Product Catalogue - 2013

N e o d e n t

K i t s

147

Contents

Surgical Kit CasePLUS Starter DrillPLUS Alvim Twister Drill 2.0PLUS Twister Drill 2.0PLUS Pilot Drill 2/3PLUS Twister Drill 2.8PLUS Twister Drill 3.0PLUS Twister Drill 3.15PLUS Twister Drill 3.3PLUS Twister Drill 3.8PLUS Twister Drill 4.3PLUS Alvim Drill 3.5PLUS Alvim Drill 4.3PLUS Alvim Drill 5.0PLUS Countersink Drill 3.5PLUS SF Countersink Drill 4.1PLUS Countersink Drill 4.3PLUS SF Countersink Drill 4.5 and 5.0PLUS CM Pilot Drill 2.8/3.5PLUS CM Pilot Drill 3/3.75PLUS CM Pilot Drill 3.3/4.0PLUS CM Pilot Drill 3.6/4.3PLUS CM Pilot Drill 4.3/5.0Drill ExtenderTi Contra-Angle Connection 4.1 and 4.3Ti Ratchet Connection 4.1 and 4.3 ShortTi Ratchet Connection 4.1 and 4.3 LongTi Contra-Angle Connection 5.0Ti Ratchet Connection 5.0 ShortTi Ratchet Connection 5.0 LongTi Short Ratchet Connection 3.5Ti Long Ratchet Connection 3.5CM Short Ratchet ConnectionCM Long Ratchet ConnectionCM Contra-Angle ConnectionTi Contra-Angle Connection 3.5CM Height Measuring ToolImplant Mount 3.3 LongParalleling Guide 2.8/3.5Paralleling Guide 3.0/3.75Paralleling Guide 3.3/4.0Paralleling Guide 3.6/4.3Paralleling Guide 4.3/5.0Short 0.9 Digital DriverShort 1.2 Digital DriverDigital Driver Contra-Angle ConnectionTorque RatchetMillimeter ProbeTitanium TweezerII Plus Short Ratchet ConnectionII Plus Long Ratchet ConnectionII Plus Contra-Angle ConnectionII Plus Countersink Drill 4.3II Plus Countersink Drill 5.0

110.251103.170103.171103.162103.213103.163103.164103.165103.166103.167103.168103.172103.173103.174103.366103.239103.211103.242103.216103.217103.218103.219103.220103.091105.047105.045105.046105.050105.048105.049105.087105.088105.073105.074105.075105.089128.015113.014128.019128.020128.021128.022128.023104.039104.007104.028104.050129.004129.001105.030105.031105.068103.296103.297

111111111111111111111111111111111111111111111111111111

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX XXX

XXXXXXX

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX

XXX

XXXXXXX

XXX

XX

X

XXXXXXXXX

XXXXXXXX

XXX

Adva

nced

Inte

rmed

iate

SurgicalKit

Page 146: Neodent Product Catalogue - 2013

148

Note: Items that compose Neodent Kits

are sold separately

Page 147: Neodent Product Catalogue - 2013

N e o d e n t

K i t s

149

Contents

Compact Surgical Kit CasePLUS Starter DrillPLUS Twister Drill 2.0PLUS Pilot Drill 2/3PLUS Twister Drill 2.8PLUS Twister Drill 3.0PLUS Alvim Drill 3.5PLUS Alvim Drill 4.3PLUS SF Countersink Drill 4.1PLUS Countersink Drill 4.3PLUS CM Pilot Drill 2.8/3.5PLUS CM Pilot Drill 3/3.75PLUS CM Pilot Drill 3.6/4.3Drill ExtenderTi Contra-Angle Connection 4.1 and 4.3Ti Ratchet Connection 4.1 and 4.3 ShortTi Ratchet Connection 4.1 and 4.3 LongCM Short Ratchet ConnectionCM Long Ratchet ConnectionCM Contra-Angle ConnectionParalleling Guide 2.8/3.5Paralleling Guide 3.0/3.75Paralleling Guide 3.6/4.3Short 0.9 Digital DriverShort 1.2 Digital DriverTorque Ratchet

110.254103.170103.162103.213103.163103.164103.172103.173103.239103.211103.216103.217103.219103.091105.047105.045105.046105.073105.074105.075128.019128.020128.022104.039104.007104.050

11111111111111111111111111

Compact Surgical Kit

Page 148: Neodent Product Catalogue - 2013

150

Note: Items that compose Neodent Kits

are sold separately.

This technique requires specific accreditation.

Information through +55 41 2169 1030

Page 149: Neodent Product Catalogue - 2013

N e o d e n t

K i t s

151

Contents

Zygomatic Surgical Kit CaseZygomatic Installer HandpieceZygomatic Contra-Angle ConnectionZygomatic Drill Exchange ConnectionZygomatic Plus Spheric Drill 2.9Zygomatic Plus Twister Drill 2.7Zygomatic Plus Pilot Twister Drill 2.7/3.3Zygomatic Plus Twister Drill 3.3Zygomatic CM Plus Countersink DrillZygomatic Plus Pilot Twister Drill 3.3/3.7Zygomatic CM Height Measuring ToolZygomatic Lip ProtectorZygomatic Bicortical ProbeZygomatic ProbeShort 1.2mm Digital DriverShort 0.9 mm Digital Driver

110.214104.042105.067105.069103.190103.191103.192103.193103.197103.208128.016124.004129.011129.012104.007104.039

1111111111111111

ZygomaticKit

Page 150: Neodent Product Catalogue - 2013

152

Note: Items that compose Neodent Kits

are sold separately

Page 151: Neodent Product Catalogue - 2013

N e o d e n t

K i t s

153

Contents

Prosthetic Kit CaseTorque Connection 0.9Torque Connection 1.2 ShortTorque Connection 1.2Torque Connection 1.6Torque Connection - ScrewdriverTorque Connection SquareConnection for Prosthetic AbutmentsShort Connection for Prosthetic AbutmentsTorque Connection 1.2 LongCM Height Measuring ToolDigital Driver for Torque ConnectionsTransfer DriverTorque Ratchet

110.213105.065105.041105.005105.006105.007105.008105.009105.044105.071128.015104.005104.016104.050

11111111111111

ProstheticKitXXXXXXXXXXXXXX

XXXXX

XX

XCo

mpl

ete

Basic

Page 152: Neodent Product Catalogue - 2013

154

PROSTHETIC SELECTION KIT FEATURES:

:: Autoclavable polymer case

:: Recommended for better planning of

Morse Taper prosthetic abutments.

Note: Items that compose Neodent Kits

are sold separately

Page 153: Neodent Product Catalogue - 2013

N e o d e n t

K i t s

155

Contents

CM Prosthetic Selection Kit CaseCM Post 3.3x4x0.8 Prosthetic SelectionCM Post 3.3x4x1.5 Prosthetic SelectionCM Post 3.3x4x2.5 Prosthetic SelectionCM Post 3.3x4x3.5 Prosthetic SelectionCM Post 3.3x4x4.5 Prosthetic SelectionCM Post 3.3x4x5.5 Prosthetic SelectionCM Post 3.3x4x6.5 Prosthetic SelectionCM Post 3.3x6x0.8 Prosthetic SelectionCM Post 3.3x6x1.5 Prosthetic SelectionCM Post 3.3x6x2.5 Prosthetic SelectionCM Post 3.3x6x3.5 Prosthetic SelectionCM Post 3.3x6x4.5 Prosthetic SelectionCM Post 3.3x6x5.5 Prosthetic SelectionCM Post 3.3x6x6.5 Prosthetic SelectionCM Post 4.5x4x0.8 Prosthetic SelectionCM Post 4.5x4x1.5 Prosthetic SelectionCM Post 4.5x4x2.5 Prosthetic SelectionCM Post 4.5x4x3.5 Prosthetic SelectionCM Post 4.5x4x4.5 Prosthetic SelectionCM Post 4.5x4x5.5 Prosthetic SelectionCM Post 4.5x4x6.5 Prosthetic SelectionCM Post 4.5x6x0.8 Prosthetic SelectionCM Post 4.5x6x1.5 Prosthetic SelectionCM Post 4.5x6x2.5 Prosthetic SelectionCM Post 4.5x6x3.5 Prosthetic SelectionCM Post 4.5x6x4.5 Prosthetic SelectionCM Post 4.5x6x5.5 Prosthetic SelectionCM Post 4.5x6x6.5 Prosthetic SelectionCM Angled Post 3.3x6x1.5 17° Prosthetic Sel.CM Angled Post 3.3x6x2.5 17° Prosthetic Sel.CM Angled Post 3.3x6x3.5 17° Prosthetic Sel.CM Angled Post 3.3x6x1.5 30° Prosthetic Sel.CM Angled Post 3.3x6x2.5 30° Prosthetic Sel.CM Angled Post 3.3x6x3.5 30° Prosthetic Sel.WS Post 4.5x6x0.8 Prosthetic SelectionWS Post 4.5x6x1.5 Prosthetic SelectionWS Post 4.5x6x2.5 Prosthetic SelectionWS Post 4.5x6x3.5 Prosthetic SelectionShort 1.2 Digital DriverCM Anatomic Post Alt. 1.5 Prosthetic Sel. *CM Anatomic Post Alt. 2.5 Prosthetic Sel. *CM Anatomic Post Alt. 3.5 Prosthetic Sel. *CM Anatomic Lateral Post Alt. 1.5 Prosthetic Sel.*CM Anatomic Lateral Post Alt. 2.5 Prosthetic Sel.*CM Anatomic Lateral Post Alt. 3.5 Prosthetic Sel.*

110.223114.191114.192114.193114.194114.195114.196114.197114.198114.199114.200114.201114.202114.203114.204114.205114.206114.207114.208114.209114.210114.211114.212114.213114.214114.215114.216114.217114.218114.219114.220114.221114.222114.223114.224114.230114.231114.232114.233104.007114.226114.227114.228114.335114.336114.337

1111111111111111111111111111111111111111111111

CM ProstheticSelection Kit

*Optional

Page 154: Neodent Product Catalogue - 2013

156156

Page 155: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

157157

NeodentInstruments

Page 156: Neodent Product Catalogue - 2013

158

Alvim Drill

Countersink Drill

Plus Starter Drill

Pilot Drill

:: Available in surgical steel and Zircon;:: Instrument sequence forsurgical alveolus in Alvim Implants.

103.174 103.255

103.173 103.254

103.172 103.253

Surgical steel Zircon

Ø 3.5

Ø 4.3

Ø 5.0

:: Available in surgical steel and Zircon;:: Preparation of bone crest for Fittingthe cervical bone Implants 3.3, 3.5,3.75, 4.0, 4.5 and 5.0mm (external hex) and 4.3 and 5.0mm (internal hex).

:: Available in surgical steel;:: Cortical rupture;:: 2.0mm diameter.

:: Available in surgical steel and Zircon;:: Increasing the surgical alveolus diameter row, easing the penetration of the next drill;:: Replaces the Countersink when usingMorse Taper Implants.

Surgical steel Zircon

103.242 103.293

103.239 103.292

103.366

103.209 103.265

External Hex

Ø 4.1(SF)

(SF)

Ø 3.5

Ø 3.3

103.211 103.267Ø 4.3

Ø 4.5/ Ø 5.0

Surgical steel Zircon

Internal Hex

Ø 4.3

Ø 5.0

103.296 103.298

103.297 103.299

103.170Ø 2.0

Surgical steel Zircon

103.216 103.272

103.269

103.218 103.274

103.219 103.275

103.220 103.276

103.213

103.217 103.273

103.214 103.270

103.215 103.271

2.8/3.5 mm

3.3/4 mm

3.6/4.3 mm

4.3/5 mm

2/3 mm

3/3.75 mm

3.8/4.3 mm

4.3/5.3 mm

103.221 103.2775.3/6 mm

Page 157: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

159

Twister Drill:: Available in surgical steel and Zircon;:: Instrument sequence for surgical alveolus in Titamax Implants;:: Length: 35mm.

Surgical steel Zircon

Ø 2.0

Alvim Ø 2.0

103.162

103.171

Ø 3.0

Ø 3.15

Ø 3.3

103.164 103.245

103.166 103.247

103.165 103.246

Ø 3.8

Ø 4.3

Ø 5.3

103.167 103.248

103.168 103.249

103.169 103.250

Ø 2.8 103.163 103.244

Paralleling Guides:: Available in Titanium;:: Instrument to guide the implant’s position;:: Diameter of central band corresponds to CM Implant diameter CM Implants;

:: Smaller side to be used after Ø2.0mm drill;:: Larger side to be used after the last drill beforeimplant Instalation.

128.019

128.020

128.021

128.022

128.023

128.024

128.025

WS

2.8/3.5

3.0/3.75

3.3/4.0

3.6/4.3

4.3/5.0

Ø 4.3/5.0

Ø 5.3/6.0

:: For Installing CM Implants with the Torque Ratchet (104.050);

:: With six marks to indicate the hex index face position;

:: The laser marks indicate the depth of implant Instalation, bone level, 1 and 2mm infra-bone and last marking (3mm) biological space.

CM Ratchet Connection

105.073 105.074

Short Long

Page 158: Neodent Product Catalogue - 2013

160

Ratchet ConnectionExternal Hex - Ti

Ratchet ConnectionInternal Hex - II Plus

:: To Install External Hex Ti Implants with a Torque Ratchet (104.050).

:: To Install Internal Hex II PLUS Implants with a Torque Ratchet (104.050);

:: With six marks to indicate the internal hexface position.

105.048

105.049

105.045

105.046

105.087

105.088

5.04.1/4.33.5

Short

Long

105.030 105.031

4.3/5.0 4.3/5.0

Short Long

CM Contra-Angle Connection

105.075:: To Install CM Implants with Contra-Angle, or attached to a Digital Driver for Contra-Angle Connections (104.028) for manual Instalation;

:: With six marks to indicate the hex index face position;:: The laser marks indicate the depth of implant Instalation, bone level, 1 and 2mm infra-bone and last marking (3mm) biological space.

Contra-Angle ConnectionInternal Hex - II Plus

:: To capture the implant directly from the package;:: To Install External Hex Ti Implants with Contra-Angle, or attached to a Digital Driver (104.028) for manual Instalation;

:: With clip to increase safety when transporting and positioning implants;

:: To capture the implant directly from the package;:: To Install Internal Hex II PLUS Implants with Contra-Angle, or attached to a Digital Driver (104.028) for manual Instalation;

:: With clip to increase safety when transporting and positioning Implants.

105.068

4.3/5.0

Contra-Angle ConnectionExternal Hex - Ti

105.047105.089 105.050

4.1/4.33.5 5.0

Page 159: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

161

128.015:: Available in Titanium;:: For selection of CM prosthetic abutments;:: Marks corresponding to transmucous heights.

1.53.55.5

2.5

6.54.5

0.8

CM Height Measuring Tool

Drill Extender:: Available in surgical steel;:: Screw for drill retaining;:: Screw attached to drill extender;:: To tighten or untighten the screw, use a half-turn on the 1.2 Digital Driver (104.007) is enough.

103.091

Titanium Tweezer:: To handle implants;:: New Tweezer system that prevents deviation in the active bit;

:: Millimeter scale for checking during procedures;

:: Self-locking implant.

129.001

Contra-Angle Hex Connection:: Available in surgical steel;:: Adaptation of hex assemblies;:: To insert implants using the motor and Contra-Angle;

:: Silicone ring for better assembly tightening and transport.

Ratchet Hex Connection(Ratchet Driver Connection):: Available in surgical steel;:: Adaptation of hex assemblies;:: Fit in square ratchets;:: Silicone ring for better tightening tightening and transport.

105.018105.001

105.002

Short Long

Page 160: Neodent Product Catalogue - 2013

162

Millimeter Probe:: Available in Titanium;:: To probe preparations and analyze depth;:: Millimeter scale for checking during procedures.

129.004

Digital Driver for Contra-Angle Connections

:: Available in surgical steel;:: Connected to Ti and II Plus Contra-Angle Connections, it becomes a manual driver for Implant Instalation.

104.028

Hex Digital Driver 0.9 mm

Hex Digital Driver 1.2 mm

:: Available in surgical steel;:: With diverging hex for better screw tighteningand transport;:: Handling cover screws for Implants3.3, 3.5, 3.75, 4.0, 4.3 and Cicatrizer 3.3 alt. 2 mm.

:: Available in surgical steel;:: With diverging hex for better screw tightening and transport.

104.040104.041104.039

Medium25 mm

Medium25 mm

Long38 mm

Long38 mm

Short20 mm

Short20 mm

Tuff Driver:: Available in stainless steel;:: Manual implant Instalation.

104.047

104.010104.012104.007

Page 161: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

163

Torque Ratchet:: Available in surgical steel;:: Extremely safe (lower than 5% variation);:: Fitting for square connections;:: Collapsible ratchet that allows for proper assembly cleaning;:: Maintenance and calibration information through Customer Service +55 41 2169 1030.

104.050

Operation Instructions

The Neodent Torque Ratchet was designed to allow the necessary torque to be applied and simultaneous verification of that torque with the same Instrument.

The Neodent Torque Ratchet comes with pre-calibrated torques: 10, 20, 32, 45 and 60 N.cm.

The ratchet function works in both directions, by simply pulling and turning the driver’s pin 180°.However, the torque measurements work only clockwise.

All that is needed is to apply force to the RATCHET Handle 1(never the ratchet body) until the value marked on theLATERAL SCALE 2 corresponds to the desired torque.

•WARNING: When inverting the torque direction, the gear may come loose from the driver body and fall. Therefore, this inversion should only be done with the driver connected to a part or outside the patient’s mouth.

Page 162: Neodent Product Catalogue - 2013

164

Prosthetic Adapting Driver:: Used for tightening analogs and milling prosthetic Abutments.

104.036

104.016

Torque Meter Drivers and Connectors:: Available in surgical steel;:: Please note the connection that matches the screw in the prosthetic Abutment;:: To control the torque, the connections should be adapted to aTorque Ratchet (104.050);:: For manual torque, the connections should be adapted to aDigital Driver (104.005).

105.009

SquareScrewdriver1.61.20.9

105.065 105.005 105.006 105.007 105.008 104.005105.041 105.042 105.044

1.6Short

1.2Short

Prosthetic Abutment

Prosthetic Abutment

Short Digital

105.071

1.2Long

:: Available in surgical steel;:: Recommended for Conical Transfer (used inclosed tray techniques).

Transfer Driver

Trephine Drill:: Available in surgical steel;:: Collecting bone cylinder;:: Implant removal.

0.35mm

103.051 103.026 103.087 103.027 103.028 103.029

Ø3.3 mm Ø 4.1 mm Ø 4.3 mm Ø 5.0 mm Ø 8.0 mm Ø10.0 mm

Page 163: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

165

Bone Profile Drill

7 and 9 mm Flag

:: Available in surgical steel;:: Used in the second surgical stage;:: Conforms the bone around the implant platform, preparing an emergency profile compatible with the prosthetic Abutment’s profile;

:: Each drill includes a guide with specific diameter.

Ø3.3 mm Ø 4.1 mm

External Hex Internal Hex

Ø 4.3 mm Ø 5.0 mm Ø 4.3 mm Ø 5.0 mm

103.039 103.030 103.085 103.031 103.102 103.103

128.026 :: Available in surgical steel; :: Recommended forprosthetic/surgical planning.:: 7 and 9 mm marks.

Angle Meter:: Available in Titanium;:: Angles: 17º and 30º;:: To select and plan the angle of prosthetic abutments during surgical procedures;

:: Suggested use: After Twister Drill 2.0.

128.017

17º

128.018

30º

Alvim RadiographicPositioner:: Available in Titanium;:: Used to verify the depth of osteotomy without opening flaps;

:: We suggest using a periapical x-ray to evaluate.

16

11.513

108

129.013 129.014129.009

Ø 3.5 mm Ø 4.3 mm Ø 5.0 mm

Page 164: Neodent Product Catalogue - 2013

166

126.001

110.180

1.8 mm 2.5 mm 3.0 mm 3.5 mm

:: Available in surgical steel;:: Concave active cutting bit for non-traumatic lifting the floor of the maxillary sinus;:: Used to prepare the surgical alveolus for Implant Instalation in the posterior maxillary region with low bone height;:: Marks from 7 to 17mm.

:: Available in surgical steel;:: Convex active bit;:: Used when the bone width is insufficient, demanding bone compression and expansion before placing the implant;

:: Marks from 7 to 17mm.

110.160 110.161 110.162 110.163

Compactors

Expanders

17 mm13 mm9 mm

15 mm11 mm7 mm

17 mm13 mm9 mm

15 mm11 mm7 mm

1.8 mm 2.5 mm 3.0 mm 3.5 mm 4.0 mm 4.5 mm

110.154 110.155 110.156 110.157 110.158 110.159

Osteotome Case:: Available in polymer;:: Autoclavable;:: Osteotomes sold separately.

Surgical Hammer:: Available in surgical steel;:: Polymer active bit;:: Used in compactors and expanders;:: Weight: 130g.

Page 165: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

167

Curette for Sinus Lifting:: Available in surgical steel;:: Used to displace the Sinusal Membrane.

126.008

1

126.009

3

126.010

4

126.011

5

126.012

7

Metallic Bone Scraper

Disposable Bone Scraper

:: Used to remove autogenous bone applied in reconstructive surgery;

:: Equipped with Titanium Nitride coated blade;

:: Silicone handle;:: Autoclavable.

127.016

Straight

127.017

Positive

127.018

Negative

127.019

Blade

:: Used to remove autogenous bone;:: Single use;:: Supplied sterile.

127.023

Page 166: Neodent Product Catalogue - 2013

168

107.003

107.008

Disposable Bone Collector:: Available in polymer;:: To collect autogenous bone;:: Single use;:: Adaptable to vacuum pump;:: Includes two disposable sieves;:: Use second tip for saliva suction (watch for contamination).

Surgical Lip Retractor124.001

Columbia Retractor :: Available in surgical steel;:: Rounded edges to minimize surgical trauma.

:: Available in surgical steel;:: Rounded edges to minimize surgical trauma.

124.003

129.008Scalpel Handle:: Available in surgical steel;:: For standard scalpel blade use;:: Blade not included;

Page 167: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

169

Blade and Bivers Handle:: Handle and blade in surgical steel;:: Non-traumatic extraction for implantInstalation;:: Similar to a periotome;:: Blades supplied individually.

129.002

129.005

Complementary Case:: Available in autoclavable polymer;:: Used to organize drills andancillary connections.

110.233

Teste

Bone Particler:: Available in surgical Stainless steel;:: Increases in bone volume;:: Blade comes with 3-year warranty, oxidation free;:: Fitted with lever for easier use;:: Bone mill pesttle with slots to optmize bone block locking during use. :: Please avoid the use of bone originated from tissue banks.

Bovine bone block withvolume = 1.76 cm3

After particling, volumegain was about 7 times.

Magnified particles.

Note: Tech Support - +55 41 2169 1030

127.011

Page 168: Neodent Product Catalogue - 2013

170

OSTELL ISQ is a portable equipment that applies Ressonance Frequency Analysis

to measure the stability of dental implants and perform bone integration monitoring.

The system includes the use of a SmartPeg, which is attached to the implant or abutment. The SmartPeg is

excited by measuring probe magnetic impulses, which generate a ressonance frequency

in response, used to calculate the implant stability value in the equipment. The higher this

value, the higher the implant stability.

The Osstell kit is composed of an equipment, probe, power supply, testing device, SmartPeg assembler,

USB cable, AC plug, user manual (SmartPegs are sold separately).

132.041

OSSTELL ISQFEATURES:

Page 169: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

171

OsstellISQSmartpegs

Smartpeg Type 01Smartpeg Type 02Smartpeg Type 03Smartpeg Type 04Smartpeg Type 05Smartpeg Type 06Smartpeg Type 07Smartpeg Type 08Smartpeg Type 09Smartpeg Type 10Smartpeg Type 11Smartpeg Type 12Smartpeg Type 13Smartpeg Type 14Smartpeg Type 15Smartpeg Type 16Smartpeg Type 17Smartpeg Type 18Smartpeg Type 21Smartpeg Type 22Smartpeg Type 23Smartpeg Type 24Smartpeg Type 25

Smartpeg Type 26Smartpeg Type 27Smartpeg Type 28Smartpeg Type 30Smartpeg Type 31Smartpeg Type 32Smartpeg Type 33Smartpeg Type 34Smartpeg Type 35Smartpeg Type 36Smartpeg Type 37Smartpeg Type 38Smartpeg Type 40Smartpeg Type 44Smartpeg Type 45Smartpeg Type 46Smartpeg Type 47Smartpeg Type 48Smartpeg Type 49Smartpeg Type 50Smartpeg Type 51Smartpeg Type 52Smartpeg Type A3

132.112132.113132.114132.115132.116132.117132.118132.119132.120132.121132.122132.123132.124132.125132.126132.127132.128132.129132.130132.131132.132132.133132.134

132.135132.136132.137132.138132.139132.140132.141132.142132.143132.144132.145132.146132.147132.148132.149132.150132.151132.152132.153132.154132.155132.156132.157

Note: Package with 5 units.

Page 170: Neodent Product Catalogue - 2013

172

NeosurgMotor

When you need to rely on high performance in oral and implant

surgery, Neodent provides the Neosurg XT Plus motor, an

internationally acknowledged tool. Silent, ergonomic, and practical,

the Neosurg motor has programs and torque control to allow

increased precision, safety and reliability during procedures. It offers

secured control to your hands. Discover the Neosurg XT Plus motor.

Neosurg XT Plus is small, light and can be

easily carried.

INTELLIGENT COMMAND PEDAL

All setups for the irrigation system, programs and speeds can be controlled through the pedal, leaving hands free for the surgical procedure. It was developed to avoid accidental system activation (progressive acceleration).

Micro Motor and Contra-Angle

REDUCED SIZE OF CONTRA-ANGLEHigh resistance Titanium body. Internal and external irrigation system. Reduced head size and ergonomically compact body. Greater visibility, access and mobility inside mouth cavity.

IRRIGATION SYSTEM WITH METAL CONNECTORSAllows perfect adaptation of the irrigation cable,offering resistance and safety. It can be sterilized.

CONTROL PANEL WITH SIMPLIFIED INTERFACE

Control Unit

Advanced design with simple and intuitive panel.Membrane type keys, with no crevices to streamline cleaning.

PERISTALTIC PUMP ATTACHED TO MOTORNo need to autoclave, only thehose system is sterilized.

MECHANICAL CALIBRATION SYSTEMBesides electronic calibration, Neosurg XT Plus has a torque meter to ensure even greater micro motor precision and contra-angle. The calibration is performed directly by the professional, with no need of manufacturer maintenance.

SHIELDED MICRO MOTOR WITH TITANIUM CASINGUses a magnetic induction system that produces neither noise nor vibration. High torque precision andspeed variation.

Page 171: Neodent Product Catalogue - 2013

N e o d e n t

I n s t r u m e n t s

173

NeosurgMotor

When you need to rely on high performance in oral and implant

surgery, Neodent provides the Neosurg XT Plus motor, an

internationally acknowledged tool. Silent, ergonomic, and practical,

the Neosurg motor has programs and torque control to allow

increased precision, safety and reliability during procedures. It offers

secured control to your hands. Discover the Neosurg XT Plus motor.

Neosurg XT Plus is small, light and can be

easily carried.

INTELLIGENT COMMAND PEDAL

All setups for the irrigation system, programs and speeds can be controlled through the pedal, leaving hands free for the surgical procedure. It was developed to avoid accidental system activation (progressive acceleration).

Micro Motor and Contra-Angle

REDUCED SIZE OF CONTRA-ANGLEHigh resistance Titanium body. Internal and external irrigation system. Reduced head size and ergonomically compact body. Greater visibility, access and mobility inside mouth cavity.

IRRIGATION SYSTEM WITH METAL CONNECTORSAllows perfect adaptation of the irrigation cable,offering resistance and safety. It can be sterilized.

CONTROL PANEL WITH SIMPLIFIED INTERFACE

Control Unit

Advanced design with simple and intuitive panel.Membrane type keys, with no crevices to streamline cleaning.

PERISTALTIC PUMP ATTACHED TO MOTORNo need to autoclave, only thehose system is sterilized.

MECHANICAL CALIBRATION SYSTEMBesides electronic calibration, Neosurg XT Plus has a torque meter to ensure even greater micro motor precision and contra-angle. The calibration is performed directly by the professional, with no need of manufacturer maintenance.

SHIELDED MICRO MOTOR WITH TITANIUM CASINGUses a magnetic induction system that produces neither noise nor vibration. High torque precision andspeed variation.

Page 172: Neodent Product Catalogue - 2013

174

Neo

dent

res

erve

s th

e ri

ght

to p

erfo

rm t

echn

ical

cha

nges

wit

hout

pri

or n

otic

e.Im

ages

for

ill

ustr

atio

n pu

rpos

es o

nly.