NDT related clauses in Section I
Citation preview
ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Presentation title - 12/05/2015 P 7
NDT in General Requirement
PG 78 : Repairs of Defects In Materials
May be, provided acceptance by the Inspector is first obtained for the method and extent of repairs
PG 90 : Inspection and Test (General)
During Construction and After Completion by AI
PG 91 : Qualification of Inspectors
Qualification of AI
PG 93 : Examination and Repair of Flat Plate in Corner Joints
For More than 14 mm, LPT and MT to be used
NDT Related Clauses in Section - I
NDE in ASME
ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Presentation title - 12/05/2015 P 8
PW 11 : Volumetric Examination of Welded Butt Joints
Table PW 11Either RT or UT until PW -11 restricts for any method
PW 40 : Repair of Defects
PW 46 : Inspection and Tests
PW 50 : Qualification of Nondestructive Examination Personnel
Written Practice must be written by employer
NDT Related Clauses in Section - I
NDE in ASME
ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Presentation title - 12/05/2015 P 9
Radiography Reference in Section - I
PW 51 : Radiographic Examination
PW 51.1 : RT as per Section VPW 51.2 : Permission for Backing StripPW 51.3 : Acceptance Standard
51.3.1 : Unacceptance of LOF, Crack, and LOP
51.3.2 : Unacceptance for Other Elongated Indication
51.3.3 : Aligned Indications ( L in 6L distance)
51.3.4 : Round Indications A 250PW 5.4 : Retention of radiograph and record for 5 years
Radiographic Examination
NDE in ASME
ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.
Presentation title - 12/05/2015 P 10
Ultrasonic Reference in Section - I
PW 52 : Ultrasonic Examination
PW 52.1 : UT as per Section V, Article 4PW 52.2 : Report Retention for 5 yearsPW 52.3 : Acceptance Standard
52.3.1 : Unacceptance of LOF, Crack, and LOP
52.3.2 : Unacceptance for Other Elongated Indication
t mentioned in 52.3.2 is thinner for 2 joints
Ultrasonic Examination