4
© ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Presentation title - 12/05/2015 – P 7 NDT in General Requirement PG 78 : Repairs of Defects In Materials May be, provided acceptance by the Inspector is first obtained for the method and extent of repairs PG 90 : Inspection and Test (General) During Construction and After Completion by AI PG 91 : Qualification of Inspectors Qualification of AI PG 93 : Examination and Repair of Flat Plate in Corner Joints For More than 14 mm, LPT and MT to be used NDT Related Clauses in Section - I NDE in ASME

NDT Related Clauses of Section I

Embed Size (px)

DESCRIPTION

NDT related clauses in Section I

Citation preview

  • ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

    Presentation title - 12/05/2015 P 7

    NDT in General Requirement

    PG 78 : Repairs of Defects In Materials

    May be, provided acceptance by the Inspector is first obtained for the method and extent of repairs

    PG 90 : Inspection and Test (General)

    During Construction and After Completion by AI

    PG 91 : Qualification of Inspectors

    Qualification of AI

    PG 93 : Examination and Repair of Flat Plate in Corner Joints

    For More than 14 mm, LPT and MT to be used

    NDT Related Clauses in Section - I

    NDE in ASME

  • ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

    Presentation title - 12/05/2015 P 8

    PW 11 : Volumetric Examination of Welded Butt Joints

    Table PW 11Either RT or UT until PW -11 restricts for any method

    PW 40 : Repair of Defects

    PW 46 : Inspection and Tests

    PW 50 : Qualification of Nondestructive Examination Personnel

    Written Practice must be written by employer

    NDT Related Clauses in Section - I

    NDE in ASME

  • ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

    Presentation title - 12/05/2015 P 9

    Radiography Reference in Section - I

    PW 51 : Radiographic Examination

    PW 51.1 : RT as per Section VPW 51.2 : Permission for Backing StripPW 51.3 : Acceptance Standard

    51.3.1 : Unacceptance of LOF, Crack, and LOP

    51.3.2 : Unacceptance for Other Elongated Indication

    51.3.3 : Aligned Indications ( L in 6L distance)

    51.3.4 : Round Indications A 250PW 5.4 : Retention of radiograph and record for 5 years

    Radiographic Examination

    NDE in ASME

  • ALSTOM 2013. All rights reserved. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited.

    Presentation title - 12/05/2015 P 10

    Ultrasonic Reference in Section - I

    PW 52 : Ultrasonic Examination

    PW 52.1 : UT as per Section V, Article 4PW 52.2 : Report Retention for 5 yearsPW 52.3 : Acceptance Standard

    52.3.1 : Unacceptance of LOF, Crack, and LOP

    52.3.2 : Unacceptance for Other Elongated Indication

    t mentioned in 52.3.2 is thinner for 2 joints

    Ultrasonic Examination

    NDE in ASME