8
Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/2002 1 NCB-EL and NCB-FL Series Network Combiner Routers NCB routers are Echelon network devices that, when used in pairs, allow you to connect multiple Echelon networks in real time, spanning great distances. These routers allow you to connect Echelon network segments isolated by great distances that cannot be spanned by conventional wire media. Maximum wire lengths are listed in the NCB Wiring Distance Limitations Table on page 4 and should be considered the ABSOLUTE MAXIMUM. In many cases, where special care is not taken to protect the specified wire from electrical noise, moisture, etc., reliable long-term operation cannot be sustained at these wire lengths. NCB-EL - Communication between two NCB-EL routers is via an Ethernet-to-Lonworks connection that uses standard CAT 5 Ethernet cross-over cable. NCB-FL - Communication between two NCB-FL routers is via an Ethernet Fiber-to-Lonworks connection that uses dedicated fiber optic wire runs. NCB-EL and NCB-FL Router Product Installation Document This document covers the procedures and specifications for installing the above listed unit(s) and when appropriate, information regarding configuration on the monitored device. For more detailed configura- tion and operation information, refer to the Network Installation Manual or Echelon Local Area Server Manual as appropriate. Ethernet Communication - EL and FL NCB-EL and NCB-FL routers allow multiple LonWorks® networks to be connected in real-time, covering distances from campus-wide to global; these routers use Internet Protocol (IP) for data transport. Communication between networks via NCB router units is "live," delayed only by the transit time through the integral routers and Ethernet channel. The NCB-EL uses standard CAT5 cross-over cable, and the NCB-FL uses dedicated fiber optic cable. Configuring the NCB-EL/NCB-FL Router NCB-EL/NCB-FL routers are always used in pairs (EL with EL and FL with FL) with one at each end of the Ethernet network path. Initial router configuration is handled by a set of DIP switches on the front of each router labeled OPTION. Switches one through six are not used; switches seven and eight are used to configure the router for the type of network media being used: 10Base2 (not used for this application), 10BaseT (used for the NCB-EL), or AUI (used for the NCB-FL). The NCB reads the DIP switch settings at power-up or after you press the RESET button. These switches are used to set the following options: Document 51895 2/12/2002 Rev A 51895:A ECN 01-683 51895:A ECN 01-683 51895:A ECN 01-683 51895:A ECN 01-683 51895:A ECN 01-683 Typical Application of NCB Routers Campus 1 Campus 1 Campus 1 Campus 1 Campus 1 Campus 2 Campus 2 Campus 2 Campus 2 Campus 2 NCB NCB NCB NCB NCB Routers Routers Routers Routers Routers Ethernet or Fiber Ethernet or Fiber Ethernet or Fiber Ethernet or Fiber Ethernet or Fiber connection connection connection connection connection Echelon Local Echelon Local Echelon Local Echelon Local Echelon Local Area Server Area Server Area Server Area Server Area Server 4WRMB 4WRMB 4WRMB 4WRMB 4WRMB RoutMB RoutMB RoutMB RoutMB RoutMB NIONs NIONs NIONs NIONs NIONs www.PDF-Zoo.com

NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/2002 1

NCB-EL and NCB-FL Series Network Combiner Routers

NCB routers are Echelon network devices that, when used in pairs, allow you to connect multiple Echelon networksin real time, spanning great distances.

These routers allow you to connect Echelon network segments isolated by great distances that cannot be spannedby conventional wire media. Maximum wire lengths are listed in the NCB Wiring Distance Limitations Table onpage 4 and should be considered the ABSOLUTE MAXIMUM. In many cases, where special care is not taken toprotect the specified wire from electrical noise, moisture, etc., reliable long-term operation cannot be sustained atthese wire lengths.

NCB-EL - Communication between two NCB-EL routers is via an Ethernet-to-Lonworks connection that usesstandard CAT 5 Ethernet cross-over cable.

NCB-FL - Communication between two NCB-FL routers is via an Ethernet Fiber-to-Lonworks connection that usesdedicated fiber optic wire runs.

NCB-EL and NCB-FL Router

Product Installation Document

This document covers the procedures and specifications for installing the above listed unit(s) and whenappropriate, information regarding configuration on the monitored device. For more detailed configura-tion and operation information, refer to the Network Installation Manual or Echelon Local Area ServerManual as appropriate.

Ethernet Communication - EL and FL

NCB-EL and NCB-FL routers allow multiple LonWorks® networks to be connected in real-time, covering distancesfrom campus-wide to global; these routers use Internet Protocol (IP) for data transport. Communication betweennetworks via NCB router units is "live," delayed only by the transit time through the integral routers and Ethernetchannel. The NCB-EL uses standard CAT5 cross-over cable, and the NCB-FL uses dedicated fiber optic cable.

Configuring the NCB-EL/NCB-FL Router

NCB-EL/NCB-FL routers are always used in pairs (EL with EL and FL with FL) with one at each end of the Ethernetnetwork path. Initial router configuration is handled by a set of DIP switches on the front of each router labeledOPTION. Switches one through six are not used; switches seven and eight are used to configure the router for thetype of network media being used: 10Base2 (not used for this application), 10BaseT (usedfor the NCB-EL), or AUI (used for the NCB-FL). The NCB reads the DIP switch settings atpower-up or after you press the RESET button. These switches are used to set the followingoptions:

Document 518952/12/2002 Rev A51895:A ECN 01-68351895:A ECN 01-68351895:A ECN 01-68351895:A ECN 01-68351895:A ECN 01-683

Typical Application of NCB Routers

Campus 1Campus 1Campus 1Campus 1Campus 1

Campus 2Campus 2Campus 2Campus 2Campus 2

NCBNCBNCBNCBNCBRoutersRoutersRoutersRoutersRouters

Ethernet or Fiber Ethernet or Fiber Ethernet or Fiber Ethernet or Fiber Ethernet or Fiberconnectionconnectionconnectionconnectionconnection

Echelon LocalEchelon LocalEchelon LocalEchelon LocalEchelon LocalArea ServerArea ServerArea ServerArea ServerArea Server

4WRMB4WRMB4WRMB4WRMB4WRMB

RoutMBRoutMBRoutMBRoutMBRoutMB

NIONsNIONsNIONsNIONsNIONs

www.PDF-Zoo.com

Page 2: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/20022

NOTE: For detailed information on NCB-EL/NCB-FL router configuration,refer to the manufacturer's documentation included with the product.

NCB-EL/NCB-FL DIP Switch Settings

Position Function

1-6 Not Used, Leave Up

7 8 Ethernet Port

UP X 10BaseT

DN UP 10Base2 (not used)

DN DN AUI

NCB-EL and NCB-FL Routers

These two routers are similar in function to the NCB-IM. Physically, they differ from NCB-IM routers in that they areexternal routers, and they communicate over Ethernet instead of a telephone line. The 10BaseT and AUI portsprovide for the connection to the Ethernet network. Only one port can be used at any one time.

Not UsedNot UsedNot UsedNot UsedNot Used

NCB-EL/NCB-FL Router Motherboard

10BASE-2 Connector10BASE-2 Connector10BASE-2 Connector10BASE-2 Connector10BASE-2 Connector(not used)(not used)(not used)(not used)(not used)

OPTION DIP SwitchesOPTION DIP SwitchesOPTION DIP SwitchesOPTION DIP SwitchesOPTION DIP Switches

10BASE10BASE10BASE10BASE10BASE-----T ConnectorT ConnectorT ConnectorT ConnectorT Connector(Etherlon)(Etherlon)(Etherlon)(Etherlon)(Etherlon)

AAAAAUI PUI PUI PUI PUI Portortortortort(Fiberlon)(Fiberlon)(Fiberlon)(Fiberlon)(Fiberlon)

PPPPPower - 24VDC INower - 24VDC INower - 24VDC INower - 24VDC INower - 24VDC IN

Status LEDsStatus LEDsStatus LEDsStatus LEDsStatus LEDs

Network LEDsNetwork LEDsNetwork LEDsNetwork LEDsNetwork LEDs

Echelon SMX TEchelon SMX TEchelon SMX TEchelon SMX TEchelon SMX TransceiverransceiverransceiverransceiverransceiverData PData PData PData PData Portortortortort

SMX DaughterboardSMX DaughterboardSMX DaughterboardSMX DaughterboardSMX DaughterboardConnectorConnectorConnectorConnectorConnector

NCB-FL Fiber Adapter

TTTTTo NCB moduleo NCB moduleo NCB moduleo NCB moduleo NCB moduleAAAAAUI PUI PUI PUI PUI Port - Fort - Fort - Fort - Fort - Fiberiberiberiberiber

TTTTTransmitransmitransmitransmitransmit

ReceiveReceiveReceiveReceiveReceive

www.PDF-Zoo.com

Page 3: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/2002 3

NCB Series Power Supply Requirements

The NCB-EL and NCB-FL require 24 VDC @ 0.050 A nominal and battery backup in accordance with local coderequirements. It can be powered by any power limited, filtered 24 VDC source, as appropriate for your area, foruse with fire protective signaling units. Power connections are made via plug-in screw terminals.

NCB-EL Installation Requirements:

1) NCB-EL Network Combiner Module2) SMX Echelon network transceiver3) NCB Power Supply (24 Volt DC 400mA, center POSITIVE, outer NEGATIVE)4) Ethernet cross-over cable for a direct connection, or a standard Ethernet cable otherwise (must be supplied

by customer)5) NISCAB-56) HSP-121B Surge Suppressor

NCB-FL Installation Requirements:

1) NCB-FL Network Combiner Module2) SMX Echelon network transceiver3) CentreCOM Fiber Optic Transceiver with provided extension cable4) NCB Power Supply (24 Volt DC 400mA, center POSITIVE, outer NEGATIVE)5) HSP-121B Surge Suppressor6) Bidirectional fiber optic cable (must be supplied by customer)7) NISCAB-5

NOTE: The NCB power supply unit requires 115 VAC, 60Hz primary power.

A UPS (Uninterruptable Power Supply) for use with fire protective signalling units isrequired for each unit.

NCB-EL/NCB-FL Status LEDs

ACT (yellow) - Activity LED (ACT); indicates a packet has been passed by the router.

ERR (red) - Error. Indicates one of three things:

a) Always on: a diagnostic error has occurred.

b) Slow flash or always on: insufficient configuration information is present.

c) Quick flash: insufficient IP configuration information.

Green - Power; indicates when power is present for the router.

NCB-EL/NCB-FL Network LEDs

ETH RX (yellow) - Ethernet Receive; indicates when a packet has been detected on the Ethernet port.

WINK (red) - Flashes for two seconds when the Control Neuron receives a Wink Network Management com-mand.

ETH TX (green) - Ethernet Transmit; indicates when a packet is transmitted on the Ethernet port.

Reset, CSVC and RSVC Buttons

Reset - Hardware reset for the entire NCB router.

CSVC - Service button for the router's Neuron processor.

RSVC - Service button for the router module.

www.PDF-Zoo.com

Page 4: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/20024

Installing the Network Transceiver on NCB Series Routers

NCB routers require an SMX network transceiver to connect to the local Echelon network segment. Any standardnetwork transceiver is supported by the NCB module. Follow these steps to install the transceiver:

1. Remove the back plate of the NCB router. CAUTIONCAUTIONCAUTIONCAUTIONCAUTION: Do not remove the router motherboard: Do not remove the router motherboard: Do not remove the router motherboard: Do not remove the router motherboard: Do not remove the router motherboardfrom the front panel.from the front panel.from the front panel.from the front panel.from the front panel.

2. Carefully remove the router motherboard from the enclosure.

3. Mount stand-offs provided with the transceiver to the motherboard.

4. Carefully mount the network transceiver by seating the header socket on the NCB SMX header.

5. Reinsert the motherboard into the NCB enclosure (be sure to attach network media to the network connec-tor on the transceiver first) and replace the back cover.

WWWWWARNINGARNINGARNINGARNINGARNING: DO NO: DO NO: DO NO: DO NO: DO NOT remove or replace the motherboard from the front panel of theT remove or replace the motherboard from the front panel of theT remove or replace the motherboard from the front panel of theT remove or replace the motherboard from the front panel of theT remove or replace the motherboard from the front panel of theenclosure. Doing so may damage the unit, causing the unit to malfunction when poweredenclosure. Doing so may damage the unit, causing the unit to malfunction when poweredenclosure. Doing so may damage the unit, causing the unit to malfunction when poweredenclosure. Doing so may damage the unit, causing the unit to malfunction when poweredenclosure. Doing so may damage the unit, causing the unit to malfunction when poweredon. Doing so will void the unit's warrantyon. Doing so will void the unit's warrantyon. Doing so will void the unit's warrantyon. Doing so will void the unit's warrantyon. Doing so will void the unit's warranty. Always remove and replace the motherboard. Always remove and replace the motherboard. Always remove and replace the motherboard. Always remove and replace the motherboard. Always remove and replace the motherboardfrom the rear of the enclosure.from the rear of the enclosure.from the rear of the enclosure.from the rear of the enclosure.from the rear of the enclosure.

NCB Wiring Distance Limitations Table

NONONONONOTE 1:TE 1:TE 1:TE 1:TE 1: Unless specifically stated otherwise, all wire described is twisted, unshielded, and protected from electrical noise to the same extentcomputer network wiring would be if run in the same areas.

NONONONONOTE 2: TE 2: TE 2: TE 2: TE 2: The technical description for wire types normally specifies the wire gauge; for instance, wire specified as CAT-5 is normally 22 or 24gauge. It takes a special effort to obtain wire that meets the electrical specifications (capacitance, characteristic impedance, velocity factor),exceeds the attenuation, and is a lower gauge wire, and technically the wire at that point would no longer be “CAT 5.” Jobs using the NCBrouters at these wire distances should be approved by Notifier prior to purchase.

Router Type Cable Type Max Distance

NCB-IM phone line Public switched telephone circuits N/A

NCB-IM leased line Leased line telephone circuits N/A

NCB-IM dry contact Voice grade (CAT5) copper pair, 22-24 AWGNote 1 6,000 to 8,000 ft

High data grade copper pairs (CAT5), heavier than normalgauge (such as 18 gauge or better) to lower resistanceNote 2 15,000 to 20,000 ft

14 to 18 gauge THHN power wire (not twisted) 3,000 to 4,000 ft

NCB-EL to NCB-EL direct CAT5 Ethernet crossover cable 300 ft

NCB-EL to NCB-EL with ENIC-HUB CAT5 EThernet cable 300 + 300 = 600 ft total

NCB-FL Multimode fiber with ST connector 32,500 ft

www.PDF-Zoo.com

Page 5: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/2002 5

Installing the NCB-EL in the NISCAB-5

Mount a single gang electrical box in the NISCAB-5 back box using self tapping screws provided. Mount the HSP-121B to the box using studs provided per the diagram on the following page. Once mounted, install a single,grounded electrical outlet in the box and connect the output from the HSP-121B. The HSP-121B must be con-nected to primary power through conduit using knockouts supplied.

1. The NISCAB-5 is provided with three shelves and stand-offs for assembly of a shelf unit; however, only thetop shelf is required for these applications.

2. Install the shelf according to the above figure.3. Run the Echelon network lines to the cabinet in conduit. Connect the network wires (or fiber) to the SMX

network transceiver.4. When installing an NCB-EL, connect the Ethernet cable to the 10BaseT connector.5. Connect the router transformer power plug to the power connector on the unit and slide the unit and shelf

into the cabinet.6. Plug the router power transformer into the electrical outlet.

NOTE: Power-limited and nonpower-limited circuits must remain separated in the cabinet. All power-limited wiring must remain at least 0.25 inches from any nonpower-limited circuit wiring. Run all non-power-limited wiring along bottom of cabinet. All power-limited and nonpower-limited circuit wiringmust enter and exit the cabinet through different knockouts and/or conduits.

NISCAB-5 Shelf Installation

NISCAB-5NISCAB-5NISCAB-5NISCAB-5NISCAB-5

TTTTTop Shelf for NCB Rop Shelf for NCB Rop Shelf for NCB Rop Shelf for NCB Rop Shelf for NCB Routerouterouterouterouter

Shelves for PNETShelves for PNETShelves for PNETShelves for PNETShelves for PNET-1-1-1-1-1

Stand-offsStand-offsStand-offsStand-offsStand-offs

CoverCoverCoverCoverCover

www.PDF-Zoo.com

Page 6: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/20026

HSP-121B/NISCAB-5 Installation

Install Outlet Using SelfInstall Outlet Using SelfInstall Outlet Using SelfInstall Outlet Using SelfInstall Outlet Using SelfTTTTTapping Screws (Papping Screws (Papping Screws (Papping Screws (Papping Screws (Provided)rovided)rovided)rovided)rovided)

Install Edco HSPInstall Edco HSPInstall Edco HSPInstall Edco HSPInstall Edco HSP-121B-121B-121B-121B-121BUsing the Studs and NutsUsing the Studs and NutsUsing the Studs and NutsUsing the Studs and NutsUsing the Studs and Nuts

as Shownas Shownas Shownas Shownas Shown

NISCAB-5NISCAB-5NISCAB-5NISCAB-5NISCAB-5

Electrical OutletElectrical OutletElectrical OutletElectrical OutletElectrical Outlet

Edco HSPEdco HSPEdco HSPEdco HSPEdco HSP-121B-121B-121B-121B-121B

Nonpower-limited WiringNonpower-limited WiringNonpower-limited WiringNonpower-limited WiringNonpower-limited Wiringin Bottom of Cabinetin Bottom of Cabinetin Bottom of Cabinetin Bottom of Cabinetin Bottom of Cabinet

NOTE: Power-limited andnonpower-limited circuits mustremain separated in the cabinet.All power-limited wiring mustremain at least 0.25 inches fromany nonpower-limited circuitwiring. Run all non-power-limitedwiring along bottom of cabinet.All power-limited and nonpower-limited circuit wiring must enterand exit the cabinet throughdifferent knockouts and/orconduits.

NCB-EL Router Installation Into the NISCAB-5

NOTE: Use only wire for power limited systems.Power limited wire runs use type FPLR, FPLP, FPLor equivalent cabling per NEC 760.

NCB Series RouterNCB Series RouterNCB Series RouterNCB Series RouterNCB Series Router

Shelf Unit for NCB RouterShelf Unit for NCB RouterShelf Unit for NCB RouterShelf Unit for NCB RouterShelf Unit for NCB Router

NISCAB-5NISCAB-5NISCAB-5NISCAB-5NISCAB-5

CoverCoverCoverCoverCover

www.PDF-Zoo.com

Page 7: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/2002 7

Installing the NCB-FL in the NISCAB-5

The NCB-FL requires the installation of a fiber cable extension between the router module and the CentreCOMFiber Optic Transceiver.

1. Attach the fiber cable extension tothe CentreCOM transceiver, andplace them on the second shelfbelow the router mounting shelf.Mount the CentreCOM transceiverto the shelf using the bracketprovided. Run the cable extensionbehindbehindbehindbehindbehind the router mounting shelfup to the router module.

2. Connect the network wires (orfiber) to the SMX network trans-ceiver.

4. Connect the fiber cable to the AUIconnector.

5. Connect the router transformerpower plug to the power connectoron the unit and slide the unit andshelf into the cabinet.

6. Plug the router power transformerinto the electrical outlet.

Installing a PNET-1 in the NCB-EL Assembly

The PNET-1 is a surge suppressor that protects an Ethernet line from power surges. Install the PNET-1 into theNISCAB-5 as shown in Figure 1-15.

Connect the Ethernet cable from the 10Base-T Ethernet connector on the NCB-EL router to the PNET-1 IN connec-tion (the square end). Run the Ethernet line from the OUT connection (the round end) to the LAN.

NISCAB-5NISCAB-5NISCAB-5NISCAB-5NISCAB-5

PNETPNETPNETPNETPNET-1-1-1-1-1

Shelf Unit for PNETShelf Unit for PNETShelf Unit for PNETShelf Unit for PNETShelf Unit for PNET-1-1-1-1-1

CoverCoverCoverCoverCover

Star WStar WStar WStar WStar Washerasherasherasherasher

PNETPNETPNETPNETPNET-1 Ground W-1 Ground W-1 Ground W-1 Ground W-1 Ground Wireireireireire

PNET-1 Installation Diagram

CentreCOM Fiber OpticCentreCOM Fiber OpticCentreCOM Fiber OpticCentreCOM Fiber OpticCentreCOM Fiber OpticTTTTTransceiverransceiverransceiverransceiverransceiver

NCB-FL Installation

Fiber cable extensionFiber cable extensionFiber cable extensionFiber cable extensionFiber cable extension

MountingMountingMountingMountingMountingBracketBracketBracketBracketBracket

www.PDF-Zoo.com

Page 8: NCB-EL and NCB-FL Router Product Installation Document · NCB-IM phone line Public switched telephone circuits N/A NCB-IM leased line Leased line telephone circuits N/A NCB-IM dry

Document 51895 NCB-EL and NCB-FL Router Installation Rev. A 2/12/20028

Using the ENIC-HUB with NCB Series Routers

The ENIC-HUB is an eight-port network hub that connects multiple devices to an Ethernet network. NCB seriesrouters connect to the hub via one of these ports. Make the connections according to the following instructions:

1. Make sure all power is disconnected.

2. Connect the NCB (10BaseT connector) to its PNET-1 suppressor (the IN connector - square end).

3. Make the ground connection on the NCB's PNET-1 suppressor.

4. Connect the NCB's PNET-1 (OUT connector - round end) to one of the ENIC-HUB's PNET-1 (OUTconnector) suppressors.

5. Connect the ENIC-HUB to the PNET-1, and make the ground connection for the PNET-1.

NCB Programming

NCB Series routers must be added or inserted in the Echelon network like any standard router and bound using theEchelon Local Area Server application.

For more information on programming the NCB Series routers, refer to the NCB Series router appendix in theEchelon Local Area Server manual.

NCB series RouterNCB series RouterNCB series RouterNCB series RouterNCB series Router

ENIC-HUBENIC-HUBENIC-HUBENIC-HUBENIC-HUB

NOTE: Use only wire for power limited systems.Power limited wire runs use type FPLR, FPLP, FPLor equivalent cabling per NEC 760.

PPPPPrimary Primary Primary Primary Primary Powerowerowerowerower(non-power limited)(non-power limited)(non-power limited)(non-power limited)(non-power limited)

PPPPPrimary Primary Primary Primary Primary Powerowerowerowerower(non-power limited)(non-power limited)(non-power limited)(non-power limited)(non-power limited)

TTTTTo Echelon Networko Echelon Networko Echelon Networko Echelon Networko Echelon Network(power limited)(power limited)(power limited)(power limited)(power limited)

TTTTTo Etherneto Etherneto Etherneto Etherneto Ethernet(power limited)(power limited)(power limited)(power limited)(power limited)

NCB Series Router Connection to ENIC-HUB

NOTE: Power-limited and nonpower-limited circuits must remain separated in the cabinet. All power-limited wiring must remain at least 0.25 inches from any nonpower-limited circuit wiring. Run all non-power-limited wiring along bottom of cabinet. All power-limited and nonpower-limited circuit wiringmust enter and exit the cabinet through different knockouts and/or conduits.

www.PDF-Zoo.com