12 fibers NanoCore Single-Jacket Micro Distribution (Plenum) 48 fibers 24 fibers Fiber Type Max. Attenuation Min OFL Bandwidth Min EMBc Bandwidth Gb Ethernet Distance 10 Gb Ethernet Distance (dB/km) (MHz-km) (MHz-km) (m) (m) 850nm (MM) or 1310nm (SM) 1300nm (MM) or 1550nm (SM) 850nm (MM) or 1310nm (SM) 1300nm (MM) or 1550nm (SM) 850nm (MM) or 1310nm (SM) 1300nm (MM) or 1550nm (SM) 850nm (MM) or 1310nm (SM) 1300nm (MM) or 1550nm (SM) 850nm (MM) or 1310nm (SM) 1300nm (MM) or 1550nm (SM) OM4* 3.0 1.0 3500 500 4700 N/A 1100 550 550 N/A OS2** 0.5 0.5 N/A N/A N/A N/A > 25,000 > 40,000 10,000 - 25,000 40,000 Product Highlights RoHS & REACH compliant. All cables utilize bend-insensitive optical fibers. Small, lightweight construction suitable for installations where space is at a premium. Ideal for Data Center environments Each fiber is color coded for easy identification. Flexible and easy to handle. Options Riser/LSZH cables available. Standard jacket color for OM4 is aqua. OM4 (OM4+) optical fiber with extended 10 GbE distances is available. Enhanced bend insensitive OS2 optical fiber is available (ITU-TG.657.B3). Cables with 3.0 mm tubes with 8,12,16 or 24 fibers per tube are available. Interlock Armored construction available. Applications Designed to withstand tight bends and accommodate difficult cabling routes with significantly lower signal loss than conventional multimode fiber. Ideal for high-density data center installations to support 10, 40 and 100 GbE and 8, 16, and 32 GFC. 144 fibers Confidential: is document contains information of a proprietary nature to Data Center Systems. Any reproduction, use or dissemination of said information in whole or part without the express written consent to Data Center Systems is prohibited. www.datacentersys.com 1881 Valley View Lane Dallas, TX 75234 972-620-4997 Optical Specifications TIA/EIA-568-C.3 ISO/ IEC 11801, 2nd edition Telcordia GR-409-CORE Notes: For OM4 cables, typical maximum attenuation is less than indicated in the Optical Specifications. For customers needing a maximum attenuation value of 2.8, please contact DCS. OS2 glass is compliant to ITU-T G.657.A1 * ** (UL) OFNP c(UL) OFNP FT6

NanoCore Single-Jacket Micro Distribution (Plenum)...NanoCore™Single-Jacket Micro Distribution (Plenum) RECOMMENDED MAXIMUM LOADS Features Fiber Count Fibers per Tube Tube Layout

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: NanoCore Single-Jacket Micro Distribution (Plenum)...NanoCore™Single-Jacket Micro Distribution (Plenum) RECOMMENDED MAXIMUM LOADS Features Fiber Count Fibers per Tube Tube Layout

12 fibers

NanoCore™Single-JacketMicro Distribution (Plenum)

48 fibers

24 fibers

Fiber Type

Max. Attenuation Min OFL Bandwidth Min EMBc Bandwidth Gb Ethernet Distance 10 Gb Ethernet Distance

(dB/km) (MHz-km) (MHz-km) (m) (m)850nm (MM)

or 1310nm

(SM)

1300nm (MM)

or 1550nm

(SM)

850nm (MM)

or 1310nm

(SM)

1300nm (MM)

or 1550nm

(SM)

850nm (MM)

or 1310nm

(SM)

1300nm (MM)

or 1550nm

(SM)

850nm (MM)

or 1310nm

(SM)

1300nm (MM)

or 1550nm

(SM)

850nm (MM)

or 1310nm

(SM)

1300nm (MM)

or 1550nm

(SM)OM4* 3.0 1.0 3500 500 4700 N/A 1100 550 550 N/A

OS2** 0.5 0.5 N/A N/A N/A N/A > 25,000 > 40,000 10,000 - 25,000 40,000

Product HighlightsRoHS & REACH compliant.All cables utilize bend-insensitive optical fibers.Small, lightweight construction suitable for installations where space is at a premium.Ideal for Data Center environmentsEach fiber is color coded for easy identification.Flexible and easy to handle.

OptionsRiser/LSZH cables available.Standard jacket color for OM4 is aqua.OM4 (OM4+) optical fiber with extended 10 GbE distances is available.Enhanced bend insensitive OS2 optical fiber is available (ITU-TG.657.B3).Cables with 3.0 mm tubes with 8,12,16 or 24 fibers per tube are available.Interlock Armored construction available.

ApplicationsDesigned to withstand tight bends and accommodate difficult cabling routes with significantly lower signal loss than conventional multimode fiber. Ideal for high-density data center installations to support 10, 40 and 100 GbE and 8, 16, and 32 GFC.

144 fibers

Confidential: This document contains information of a proprietary nature to Data Center Systems. Any reproduction, use or dissemination of said information in whole or part without the express written consent to Data Center Systems is prohibited.

www.datacentersys.com1881 Valley View Lane Dallas, TX 75234972-620-4997

Optical SpecificationsTIA/EIA-568-C.3 ISO/ IEC 11801, 2nd edition Telcordia GR-409-CORE

Notes: For OM4 cables, typical maximum attenuation is less than indicated in the Optical Specifications. For customers needing a maximum attenuation value of 2.8, please contact DCS.

OS2 glass is compliant to ITU-T G.657.A1

*

**

(UL) OFNP c(UL) OFNP FT6

Page 2: NanoCore Single-Jacket Micro Distribution (Plenum)...NanoCore™Single-Jacket Micro Distribution (Plenum) RECOMMENDED MAXIMUM LOADS Features Fiber Count Fibers per Tube Tube Layout

Confidential: This document contains information of a proprietary nature to Data Center Systems. Any reproduction, use or dissemination of said information in whole or part without the express written consent to Data Center Systems is prohibited.

NanoCore™Single-JacketMicro Distribution (Plenum)

RECOMMENDED MAXIMUM LOADS

Features

Fiber Count Fibers per Tube Tube Layout

Tube OD 50 UM OM4

8.3 UM OS2

in. mm12 - - - - 350-0006-574 350-0006-17424 12 2+FxCSM 0.079 2.0 350-0007-574 350-0007-17448 12 4xCSM 0.079 2.0 350-0009-574 350-0009 17472 12 6xCSM 0.079 2.0 350-0010-574 350-0010-17496 12 8xCSM 0.079 2.0 350-0015-574 350-0015-174

Fiber Count

Fibers per

Tube

Tube Layout

Tube OD Cable ODTensile Load

Cable WeightInstall Operation

in. mm in. mm lbs N lbs N lbs/kft Kg/Km12 - - - - 0.118 3.0 100 445.1 30 133.5 5.9 8.824 12 2+FxCSM 0.079 2.0 0.234 5.9 150 667.6 45 200.3 20.7 30.848 12 4xCSM 0.079 2.0 0.256 6.5 150 667.6 45 200.3 25.6 38.172 12 6xCSM 0.079 2.0 0.295 7.5 150 667.6 45 200.3 36 53.696 12 8xCSM 0.079 2.0 0.344 8.7 150 667.6 45 200.3 48.5 72.2

144 12 9x3xCSM 0.079 2.0 0.39 9.9 150 667.6 45 200.3 54.1 80.5

www.datacentersys.com1881 Valley View Lane Dallas, TX 75234972-620-4997

Abbreviations:CSM = Central Strength Member, F = Filler

Notes: 24-strand single-tube layout has two 12-strand bundles that are separated by colored nylon binders. Bundles of 8 also available.

*

(UL) OFNP c(UL) OFNP FT6

Storage: Installation: Operating:

Cable Temperature Ranges

40° to 70°C (-40° to 158°F)0° to 60°C (32° to 140°F)0° to 70°C (32° to 158°F)

-

Mechanical SpecificationsBend radius, no load = 10x cable overall diameter

Bend radius, load = 15x cable overall diameter

Compliant to TIA 568-C.3, ISO/IEC 11801 & Telcordia GR-409.