8
Water Analysis www.mn-net.com Fascination spectrophotometer NANOCOLOR ® VIS Safe water and waste water analysis NANOCOLOR ® Barcode Technology for fast measurements Colored touch screen with intuitive user guidance High resolution scans Turbidity measurements according to EN ISO 7027 CIE-compliant color measurements Internal quality control according to ISO 9001 USB interface for update and data transfer Integrated turbidity control in COD analysis

Nanocolor

Embed Size (px)

DESCRIPTION

VIS/Spectrophotometer

Citation preview

Page 1: Nanocolor

Water Analysis

MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6-8 · D-52355 Düren · DeutschlandFrankreich:MACHEREY-NAGEL EURLTel.: +33 (0) 3 88 68 22 68Fax: +33 (0) 3 88 51 76 88E-Mail: [email protected]

Schweiz:MACHEREY-NAGEL AGTel.: +41 (0) 62 388 55 00Fax: +41 (0) 62 388 55 05E-Mail: [email protected]

Deutschlandund International:Tel.: +49 (0) 24 21 96 90Fax: +49 (0) 24 21 96 91 99E-Mail: [email protected]

www.mn-net.com

www.mn-net.comMACHEREY-NAGEL

EN ISO 9001: 2008ZERTIFIZIERT

USA:MACHEREY-NAGEL Inc.Tel.: +1 484 821 0984Fax: +1 484 821 1272E-Mail: [email protected]

Fascination spectrophotometerNANOCOLOR® VIS•Safe water and waste water analysis•NANOCOLOR ® Barcode Technology for fast measurements•Colored touch screen with intuitive user guidance•High resolution scans•Turbidity measurements according to EN ISO 7027•CIE-compliant color measurements•Internal quality control according to ISO 9001•USB interface for update and data transferN

AN

OC

OLO

R® V

IS Integrated

turbidity control

in COD analysis

Page 2: Nanocolor

NANOCOLOR ® VIS

www.mn-net.com www.mn-net.com

Innovative precisionVIS Spectrophotometer with reference detector technology (RDT)•PowerfulVISspectrophotometerwithmonochromator(340-1100nm)•Foruniversaluseinallareasofwaterandwastewateranalysis

Highly accurate measurements by using high-quality optical components•Precisionopticsandreferencedetectortechnology(RDT)ensureaccurateresults•Highresolutionscansarerecordedanddisplayedwithinseconds

Save timeFast measurements – NANOCOLOR® barcode technology

•Fullyautomatic,instantcuvettedetection•Testmethodandwavelengthselection,themeasurementitselfandresultstorageareall

carried out automatically

Measurement without cuvette slot cover•Theprogressivelydesignedopticsisinsensitivetoexternallightandmakesmeasuringstraightforward

No cuvette adapter required•Universalcuvetteslotfortheuseoftubes(16mmOD)and rectangularcuvettes(2,10,20,50mm)withoutanyadaptor

Increase accuracySelf-explanatory user guidance•Alltestsandmenuitemscanbeactivatedfastandeasily•Operationwithoutcomplexandtime-consumingtraining

User-friendly, backlit touch screen•Allsignificantdataandfunctionsareclearlyshownonthecolored, backlittouchscreendisplay

Manual with test instructions, presented as pictograms•Easytounderstandpictogramsmakerunningtestsverysimpleandconvenient

Page 3: Nanocolor

NANOCOLOR ® VIS

www.mn-net.com www.mn-net.com

Assure resultsDocumentation of results according to GLP•Individualentriesofsamplenumber,samplelocation,useranddilution•Graphicdisplayofresults,includingtomeasurementrangeand

optional 20–80% range

Clear memory management•GLP-conformstorageofresultswithallsupplementaryinformationsuchasdate, time,samplenumber,samplelocation,useranddilution

•Fastandeasyaccesstostoredresultsanddatasets

Time saving sample allocation with the NANOCOLOR ® USB handheld scanner•Easyadministrationofsamplelocations•Classificationofresultswithinseconds•Comfortablepreparationofsamplelists

Experience flexibilityPreprogrammed tests and free programming of user-defined applications

•Easyaccesstoallphotometricbasicfunctions•Morethan200preprogrammedtestsandspecialmethods•Determinationofthespectralabsorptioncoefficient(SAC)at436nm•ColordeterminationaccordingtoDINENISO7887at3wavelengths•Freeprogrammingofupto100user-definedmethods

Page 4: Nanocolor

NANOCOLOR ® VISInnen Headline 16pt Orange_WeißHinterlegtInnenFließtext10ptSchwarz

www.mn-net.com www.mn-net.com

Powerful PC-Software – free of charge Convenient data export•EasytransferofresultsandspectratoPC•DatastorageonUSBstick(includedindelivery)

Professional data and spectrum processing•EasyprocessingoftransferreddataeitherwiththePC-softwarefor

NANOCOLOR® spectrophotometer or with standard software

Comprehensive spectrum analysis•Clearlydisplayedspectra•Automaticandmanualpeakanalysis

Photometer control via PC•Convenientdevelopmentandadministrationofspecialmethods•Numerousadditionalmeasuringprogramssuchasscankinetics,

multi-wavelength measurements

Meet specificationsInternal quality control according to ISO 9001

Passwordprotection Integrated measuring and day counter Flag standard measurements

Automatic generation of a printable quality control card

Test and standard LOT

Set value of standard incl. tolerance levels

Test and standard description

Page 5: Nanocolor

NANOCOLOR ® VISInnen Headline 16pt Orange_WeißHinterlegtInnenFließtext10ptSchwarz

www.mn-net.com www.mn-net.com

Ensure quality

Integrated equipment monitoring

Integrated lamp test

Lamppowertest at different wavelengths

Wavelength accuracy test

Built-in,internationallyacceptedholmiumoxidefilter

...and much more

ScatteredlightaccordingtoDABandPhEur

Signaltonoiseratiocheck

Photometricaccuracytestwith NANOCONTROLNANOCHECKsolutions

MACHEREY-NAGEL GmbH & Co. KG Neumann-Neander-Str. 6-8 • D-52355 Düren • GermanyPhone: +49 (0) 2421 969 0 • Fax: +49 (0) 2421 969 199 • [email protected]

www.mn-net.comPC-POLLMEIERVIS\PollmeierK\15:48:36 Page 1 / 1Software V 4.3.0.0

Inspection Equipment Monitoring 01.03.2012

NANOCOLOR® VISTest of Wavelength Correctness (Holmiumoxyde Filter)

Photometer S/N : NVIS0012

Company : MACHEREY-NAGEL GmbH & Co. KG

Operator : PollmeierK

Peak 1: Set 360,4 nm, Measured 361,0 nm , Delta : 0,6 nm (+)

Peak 2: Set 452,8 nm, Measured 452,8 nm , Delta : 0,0 nm

Peak 3: Set 536,6 nm, Measured 535,8 nm , Delta : 0,8 nm (-)

Peak 4: Set 637,2 nm, Measured 636,8 nm , Delta : 0,4 nm (-)

Wavelength correctness test passed. ________________Signature

MACHEREY-NAGEL GmbH & Co. KG Neumann-Neander-Str. 6-8 • D-52355 Düren • GermanyPhone: +49 (0) 2421 969 0 • Fax: +49 (0) 2421 969 199 • [email protected]

www.mn-net.comPC-POLLMEIERVIS\PollmeierK\15:47:07 Page 1 / 1Software V 4.3.0.0

Inspection Equipment Monitoring 01.03.2012

NANOCOLOR® VISTest of the halogene lamp

Photometer S/N : NVIS0012

Company : MACHEREY-NAGEL GmbH & Co. KG

Operator : PollmeierK

Rel. Energy values at 340 nm : 175000 (min. 42000)

Rel. Energy values at 950 nm : 2065400 (min. 300000)

360 nm = 276700 (min. 150000)

The energy values of the halogene lamp are inside the tolerance range.

________________Signature

Integrated

HoO filter

Original test report: lamp power and wavelength accuracy

Automaticsystemcheck

Page 6: Nanocolor

NANOCOLOR ® VIS

www.mn-net.com www.mn-net.com

Enjoy versatilityCIE-compliant color measurementsInmanyindustrialsettings,theproduct’scolorisanimportantqualitycriterion.Inordertoestablisharelationshipbetweenhuman color perception and physical color stimulus specification, the InternationalCommission on Illumination (CIE –commission internationalede l’éclairage)has,already in theyear1931,definedtheCIEnorm-valencysystemandCIEnormcolorsystem,respectively.TheabovementionedsystemconstitutesthefoundationforcolormeasurementswiththeNANOCOLOR® VIS.•CIE-L*a*b*,CIE-L*Ch,CIE-L*u*v*,Hunter-Lab,RGB,CMYK,HSB,HSL,YUV,tristimulusvaluesX,Y,Z,etcetera•Hazen/APHA/PtCo-,Gardner-,Saybolt-,Klett-,Iodine-,Hess-Ives-,ASTM-,Ph.Eur.-,ADMI-colorindexetcetera

•Determinationofcolordifferencesagainstaqualitycontrolreferenceaccordingtoclassicandmodernstandards (ΔECIE1976,ΔECIE1994,ΔECIE2000,ΔECMC(1:1),ΔECMC(2:1),ΔEDIN99)

•Easydeterminationagainstnumerousstoredreferencevalues

MEBAK – beer color, bitterness units, VDK and more•Reliabledeterminationofallimportantparameterslikebeercolor,bitternessunits,vicinaldiketones,totalpolyphenoles,anthocyanogenes,-acids,photometricaliodinesampleetc.

Be prepared for the futureFast photometer update – free of charge•Atanytime,stayup-to-datebyeasyprogramupdatingvia Internet/PCandUSBstick•Forthecurrentsoftwareupdatepleasevisitwww.mn-net.com

Page 7: Nanocolor

NANOCOLOR ® VISInnen Headline 16pt Orange_WeißHinterlegtInnenFließtext10ptSchwarz

www.mn-net.com www.mn-net.com

See clearNephelometric turbidity measurements according to EN ISO 7027•Determinationofscatteredlightata90°angle(nephelometric)at860nminarangefrom1to1000NTU/FNU.•Absorptionmeasurementata180°angle(turbidimetric)at550nminarangeof1to100FAUandat860nminarangeof2to400FAU

•TurbiditycontrolinCODanalysis

Integrated automatic turbidity controlInphotometricanalysis,turbidityasasourceoferrorisoftenunderestimated.Turbidityiscausedbyparticlesthatareal-readywithinthewatersample,orareformedduringananalyticalreaction.Inbothcases,theresultingturbidityimpactsthemeasurementvaluewhilevisualdetectionmaybetricky.Experienceshows,thatevenlowturbidityvaluesthatcannotbedetectedwiththehumaneye,maysignifi-cantly interfere with analytical results. • Worldwideuniquesolutionforturbidityproblems• Automaticturbiditycontrolfortubetests• DirectdisplayofturbiditiesinNTUaccordingtoDINISO7027• Warningaboutpotentialinterferencescausedbyturbidity• Maximummeasurementsafety

Be mobileVariable power supply•Classicmainsconnectiontochargetheinstrument•Useacaradaptertochargeinyouvehicle•Externalbatterypackforon-siteandthefielduse

Transport case with rechargeable batteries•Mobileapplicablespectrophotometer•Safetransportoftheinstrumentandallimportantaccessories•In-fieldmeasurementsarepossible

Spectrophotometer NANOCOLOR ® VIS

Powersupplyandchargerforexternalbatterypack

Externalbatterypack for mobile use

Calibration cuvette

Accessories

Turbidity is not always easy to identify

Page 8: Nanocolor

NANOCOLOR ® VIS

KATD

E100109/FlyerN

ANOVISde2/3/0/02.2012PD

PrintedinGermany

MACHEREY-NAGEL GmbH & Co. KG · Neumann-Neander-Str. 6–8 · 52355 Düren · GermanyFrance:MACHEREY-NAGEL EURLTel.: +33 388 68 22 68Fax: +33 388 51 76 88E-mail: [email protected]

Switzerland:MACHEREY-NAGEL AGTel.: +41 62 388 55 00Fax: +41 62 388 55 05E-mail: [email protected]

Germanyand international:Tel.: +49 24 21 969-0Fax: +49 24 21 969-199E-mail: [email protected]

www.mn-net.com

www.mn-net.comMACHEREY-NAGEL

EN ISO 9001: 2008CERTIFIED

Technical dataType: VISSpectrophotometerwithreferencedetectortechnology(RDT)Light source: Halogen lampOptical system: MonochromatorWavelength range: 340–1100nmWavelength accuracy: ± 1 nmWavelength resolution: 0.3nmWavelength calibration: AutomaticWavelength selection: Automatic,barcode,manualScan speed: 1 complete scan in less than 1 minSpectral bandwidth: <4nmPhotometric range: ±3,0Einwavelengthrange400-900nmPhotometric accuracy: 0.005Eat0.0–0.5E;1%at0.5–2.0EPhotometric linearity: <0.5%at2E;≤1%at>2EStray light: <0.5%Measuring modes: Morethan200preprogrammedtests,100optionallyprogrammablemethods,absor-

bance,transmission,factor,kinetics,2-pointcalibration,scan,nephelometricturbiditymeasurement

Cuvette holder: Testtubes16mmOD,rectangularcuvettes2,10,20,40,50mmData memory: 1000measureddatasets,GLPconformDisplay: Colored,backlitLCDtouchscreenOperation: Barcodetechnology,displayuserguidance,touchscreenLanguages: de,en,fr,es,nl,it,hu,pl,pt,czExternal light: Insensitive,opencuvetteslotInterfaces: USBandbi-directionalserialRS232Update: ViaInternet/PCandUSBstick(includedindelivery)Operating range: 10–40°C,max.80%relativehumidity(withoutcondensation)Power supply: 12VDC/2.0ADimensions L / W / H: 325/215/115mmWeight: 2kgWarranty: 2 years

This device complies with the following directives: -2006/95/EG-Low-VoltageDirective -2004/108/EG-EMV-Directive

Ordering informationSpectrophotometer NANOCOLOR® VIS REF 919 150 incl.PCsoftwareforspectrophotometers,quickreference guide,manual,dustcover,mainsadaptor,USBcable, USBstick,calibrationcuvetteandcertificateAccessories and spare parts:Case for NANOCOLOR® VIS REF 919 151 Cover for cuvette slot for NANOCOLOR® VIS REF 919 152 BatterypackforNANOCOLOR® VIS REF 919 153 Halogen lamp for NANOCOLOR® VIS REF 919 154 DustcoverforNANOCOLOR® VIS REF 919 155 MainsadaptorNANOCOLOR® VIS REF 919 156 AdaptorforcarsforNANOCOLOR® VIS REF 919 157NANOCOLOR® USB-stick REF 919 123 Handheld scanner for NANOCOLOR® spectrophotometers REF 919 134

Yourlocaldistributor: