Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
N1 Critical Technologies is proud to offer Industrial-Rated Enclosures for backup power systems in challenging or alternative applications.
INDUSTRIAL ENCLOSURES for alternative applications
Engineered to meet the challenges posed by these markets: water/wastewater treatment • transportation–railroad/bridges/tunnels/toll/lane controlmanufacturing, process control • machine builders • food and beverage • pulp and paperautomotive • ISP- BDA/DAS • oil and gas • marine
Industrial Enclosures are engineered to accommodate challenging power quality and emergency system applications like:• AC Input, AC or DC output• Extended runtime configurations
• Industrial environments• Shock and vibration• Outdoor• Dust/dirt• Mobile/portable• High temperature, direct sun-light• Rain, snow, dripping water, humidity• Caustic chemical, corrosive environment• Free standing, wall/pole mount
Understanding NEMA RatingsNEMA 1 (IP10- Indoor*)Protection from: falling dirt
NEMA 12 (IP52- Indoor*)Protection from: falling dirt, dust, lint, dripping and lightly splashed liquids
NEMA 3R (IP14- Indoor/outdoor*)Protection from: falling dirt, rain, sleet, snow, ice
NEMA 3 (IP54- Indoor/outdoor*)Protection from: falling dirt, rain, sleet, snow, ice and windblown dust
NEMA 4 (IP66- Indoor/outdoor*)Protection from: falling dirt, rain, sleet, snow, ice, windblown dust, splashing water, hose-directed water
“X”- Stainless steel, 304/316 options, corrosion resistance
* protect user fromincidental contact withequipment
Standard DesignConstruction:• NEMA Type 12, 3/R, 4 and IP rated• 6, 12, 18, 30 and 42U heights• 24” W x 36” D• Carbon steel• RAL-7035 light gray paint• Single door, dual-access with
front and rear door• Locking, pad-locking door with 3-point
latching mechanism and hidden hinges• Lifting eyes• 4-inch “C” channel leg stands• Foam in place, water and chemical resistant gasketing• 2 sets/4 post heavy duty mounting rails for rack mounted equipment• 6-inch gland plate for input/output connections• Media pocket on front door
Thermal Management• Door mounted, 6-inch ventilation fan- 133 CFM,
user defined voltage• Door mounted, 6-inch ventilation louvers,
grill and filter
INDUSTRIAL ENCLOSURES for alternative applications
12U NEMA 3R Enclosure, With Ventilation
KH 4-6-2017Drawing No. 1022 Rev. 1Part Number : HMA12U2436
36.00
24.00
TOP Without Sun Shield
32.75
REAR
26.50
Filtered Exhaust Louvers
38.00
RIGHT SIDE
36.00
Roof Sun Shield
Conduit Gland Plate
REAR Without Door
30
G LGN
L N G L N G
Optional Distribution
12U
FRONT Without Door
Sun shield
21.0026.50
NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fan Internal 12U 19" four post rack rails adjustable front to rearOptional distribution Optional bypass Front blanking panels also added to control air flow (not shown)Shown with optional 2U UPS and 2ea. 2U EBM’s
NOTES:
18U NEMA 3R Enclosure, With Ventilation
REAR
KH 4-6-2017Drawing No. 1023 Rev. 1Part Number : HMA18U2436
36.00
24.00
TOP Without Sun Shield
42.50
38.00
RIGHT SIDE
36.00
Roof Sun Shield
Conduit Gland Plate
REAR WITH OUT DOOR
30
G LGN
L N G L N G
Optional Distribution
18U
FRONT WITHOUT DOOR
Sun shield
NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fan Internal 18U 19" four post rack rails adjustable front to rearOptional distribution Optional bypassFront blanking panels also added to control air flow (not Shown)
NOTES:
30U NEMA 3R Enclosure, With Ventilation
KH 4-13-2017Drawing No. 1024 Rev. 1Part Number : HMA30U2436
REAR
Filtered Exhaust Louvers
FRONT WITHOUT DOOR Sun shield
58.00
30U
36.00
24.00
TOP Without Sun Shield
57.90
38.00RIGHT SIDE
36.00
Roof Sun Shield
Conduit Gland Plate
NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fanInternal 30U 19" four post rack rails adjustable front to rearOptional distributionOptional bypassFront blanking panels also added to control air flow (Not Shown)
NOTES:
REAR WITH OUT DOOR
3
0
G LGN
LNG LNG
64.30
Optional Distribution
42U NEMA 3R Enclosure, With Ventilation
KH 4-14-2017Drawing No. 1025 Rev. 1Part Number : HMA42U2436
REAR
Filtered Exhaust Louvers
Sun shield
FRONT WITHOUT DOOR
79.00
42U
36.00
24.00
TOP Without Sun Shield
85.40
Conduit Gland Plate
38.00RIGHT SIDE
36.00
Roof Sun Shield
REAR WITH OUT DOOR
30
G LGN
LN G LNG
Optional Distribution
NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fan Internal 42U 19" four post rack rails adjustable front to rearOptional distribution Optional bypass Front blanking panels also added to control air flow (not shown)
NOTES:
6U NEMA 3R Enclosure, With Ventilation
KH 4-14-2017Drawing No. 1021 Rev. 1Part Number : HMA241636
36.00
16.00
TOP Without Sun Shield
FRONT Without Door
24.00
Sun shield
6U
REAR Without Door
3 0
GL
GN
LN
GLN
G
4" base
Optional Distribution
NEMA 3RCabinet has insulationOptional Forklift Base AND Lift eyes Optional wall mounting plateUp to 283CFM Thermostatically controlled fan Internal 6U 19" Horizontal four post rack rails adjustable front to rearOptional distribution Optional bypassFront blanking panels also added to control air flow (not shown)Shown with optional 2U UPS and 2U EBM’s
NOTES:
30.30Conduit
Gland Plate
38.00
RIGHT SIDE
36.00
Sun Shield
FRONT
Filtered 6" Fan Pressurizing The
Cabinet
Optional .19" Wall Mounting
Plate
6U 12U 18U 30U 42U
Wall-Mount Enclosures• 4U wall-mount power enclosure• 6U wall/pole mounted, freestanding
convertible enclosure• Wall-mount brackets• Insulated cabinet• Internal UPS mounting plate
2U NEMA 3R Enclosure, With Ventilation Wall Mount
KH 4-12-2017Drawing No. 1020 Rev. 1Part Number : HMA412412WM
24.00
41.00
Front door closed
Right side UPS in Service position Front Door Open UPS in Service position
Right side UPS in Normal position
17.70
Input Output terminal block and bypass
Front Door Open Showing UPS InstalledWall Mount Brackets Atached
NEMA 3RCabinet has insulationWall Mount brackets Up to 283CFM Thermostatically controlled fanInternal UPS Mounting PlateOptional distributionOptional bypassShown with optional 2U UPS
NOTES:
2U NEMA 3R Enclosure, With Ventilation Wall Mount
KH 4-12-2017Drawing No. 1020 Rev. 1Part Number : HMA412412WM
24.00
41.00
Front door closed
Right side UPS in Service position Front Door Open UPS in Service position
Right side UPS in Normal position
17.70
Input Output terminal block and bypass
Front Door Open Showing UPS InstalledWall Mount Brackets Atached
NEMA 3RCabinet has insulationWall Mount brackets Up to 283CFM Thermostatically controlled fanInternal UPS Mounting PlateOptional distributionOptional bypassShown with optional 2U UPS
NOTES:
Standard OptionsConstruction:• Stainless Steel (304/316L)• Custom paint- user specified, standard RAL colors• Front door only• User defined security, access control and door handles• EMI/RFI attenuating gasketing• Seismic mounting and vibration attenuation• Sliding and fixed shelves• Sub-panel for din-rail mounted equipment• Interior lighting and door window kits
Thermal Management• Full interior Insulation–R7• Full coverage sunscreen, door drip shields• 10” ventilation fan- 306 CFM• Air conditioning- user or application defined BTU and
operating voltage• Mission critical venting–mechanical louvers,
H2 sensor and controls (required for Type 4/X, sealed enclosure applications)• Heater• Thermostat or timer• 18-inch leg stands or heavy duty casters
Power Input/Output• Custom power distribution din rail• Main power disconnect/circuit breaker• Terminal blocks for main power input/output and accessory power• Terminal blocks and relays for dry contact communication• Convenience receptacles–user specified
Custom Options*Construction:• NEMA Type 12, 3/R, 4/X and IP ratings
• User or application-defined dimensions; custom H x W x D
• Carbon, stainless steel (304/316L) and aluminum; user andapplication-specified gauges
• One, two or multi-door front, or dual access withdoors front and rear
• Marine-grade and corrosion resistant coatings
• Fixed-mount equipment installation including large 3P UPS
• DC power systems–chargers and custom battery solutions
• Battery rack-mounting
* All “Standard Options” listed on inside page can be selectedas part of a full custom enclosure
(877) [email protected]
www.n1critical.com • www.lithium-ion-ups.com211 N. Parker Drive, Janesville, WI 53545