N1 Critical Technologies is proud to offer Industrial-Rated Enclosures for backup power systems in challenging or alternative applications. INDUSTRIAL ENCLOSURES for alternative applications Engineered to meet the challenges posed by these markets: water/wastewater treatment transportation–railroad/bridges/tunnels/toll/lane control manufacturing, process control machine builders food and beverage pulp and paper automotive ISP- BDA/DAS oil and gas marine

N1 Critical Technologies is proud to offer · Industrial-Rated Enclosures. for backup power systems in challenging or ... • 2 sets/4 post heavy duty mounting rails for rack mounted

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: N1 Critical Technologies is proud to offer · Industrial-Rated Enclosures. for backup power systems in challenging or ... • 2 sets/4 post heavy duty mounting rails for rack mounted

N1 Critical Technologies is proud to offer Industrial-Rated Enclosures for backup power systems in challenging or alternative applications.

INDUSTRIAL ENCLOSURES for alternative applications

Engineered to meet the challenges posed by these markets: water/wastewater treatment • transportation–railroad/bridges/tunnels/toll/lane controlmanufacturing, process control • machine builders • food and beverage • pulp and paperautomotive • ISP- BDA/DAS • oil and gas • marine

Page 2: N1 Critical Technologies is proud to offer · Industrial-Rated Enclosures. for backup power systems in challenging or ... • 2 sets/4 post heavy duty mounting rails for rack mounted

Industrial Enclosures are engineered to accommodate challenging power quality and emergency system applications like:• AC Input, AC or DC output• Extended runtime configurations

• Industrial environments• Shock and vibration• Outdoor• Dust/dirt• Mobile/portable• High temperature, direct sun-light• Rain, snow, dripping water, humidity• Caustic chemical, corrosive environment• Free standing, wall/pole mount

Understanding NEMA RatingsNEMA 1 (IP10- Indoor*)Protection from: falling dirt

NEMA 12 (IP52- Indoor*)Protection from: falling dirt, dust, lint, dripping and lightly splashed liquids

NEMA 3R (IP14- Indoor/outdoor*)Protection from: falling dirt, rain, sleet, snow, ice

NEMA 3 (IP54- Indoor/outdoor*)Protection from: falling dirt, rain, sleet, snow, ice and windblown dust

NEMA 4 (IP66- Indoor/outdoor*)Protection from: falling dirt, rain, sleet, snow, ice, windblown dust, splashing water, hose-directed water

“X”- Stainless steel, 304/316 options, corrosion resistance

* protect user fromincidental contact withequipment

Standard DesignConstruction:• NEMA Type 12, 3/R, 4 and IP rated• 6, 12, 18, 30 and 42U heights• 24” W x 36” D• Carbon steel• RAL-7035 light gray paint• Single door, dual-access with

front and rear door• Locking, pad-locking door with 3-point

latching mechanism and hidden hinges• Lifting eyes• 4-inch “C” channel leg stands• Foam in place, water and chemical resistant gasketing• 2 sets/4 post heavy duty mounting rails for rack mounted equipment• 6-inch gland plate for input/output connections• Media pocket on front door

Thermal Management• Door mounted, 6-inch ventilation fan- 133 CFM,

user defined voltage• Door mounted, 6-inch ventilation louvers,

grill and filter

INDUSTRIAL ENCLOSURES for alternative applications

12U NEMA 3R Enclosure, With Ventilation

KH 4-6-2017Drawing No. 1022 Rev. 1Part Number : HMA12U2436

36.00

24.00

TOP Without Sun Shield

32.75

REAR

26.50

Filtered Exhaust Louvers

38.00

RIGHT SIDE

36.00

Roof Sun Shield

Conduit Gland Plate

REAR Without Door

30

G LGN

L N G L N G

Optional Distribution

12U

FRONT Without Door

Sun shield

21.0026.50

NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fan Internal 12U 19" four post rack rails adjustable front to rearOptional distribution Optional bypass Front blanking panels also added to control air flow (not shown)Shown with optional 2U UPS and 2ea. 2U EBM’s

NOTES:

18U NEMA 3R Enclosure, With Ventilation

REAR

KH 4-6-2017Drawing No. 1023 Rev. 1Part Number : HMA18U2436

36.00

24.00

TOP Without Sun Shield

42.50

38.00

RIGHT SIDE

36.00

Roof Sun Shield

Conduit Gland Plate

REAR WITH OUT DOOR

30

G LGN

L N G L N G

Optional Distribution

18U

FRONT WITHOUT DOOR

Sun shield

NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fan Internal 18U 19" four post rack rails adjustable front to rearOptional distribution Optional bypassFront blanking panels also added to control air flow (not Shown)

NOTES:

30U NEMA 3R Enclosure, With Ventilation

KH 4-13-2017Drawing No. 1024 Rev. 1Part Number : HMA30U2436

REAR

Filtered Exhaust Louvers

FRONT WITHOUT DOOR Sun shield

58.00

30U

36.00

24.00

TOP Without Sun Shield

57.90

38.00RIGHT SIDE

36.00

Roof Sun Shield

Conduit Gland Plate

NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fanInternal 30U 19" four post rack rails adjustable front to rearOptional distributionOptional bypassFront blanking panels also added to control air flow (Not Shown)

NOTES:

REAR WITH OUT DOOR

3

0

G LGN

LNG LNG

64.30

Optional Distribution

42U NEMA 3R Enclosure, With Ventilation

KH 4-14-2017Drawing No. 1025 Rev. 1Part Number : HMA42U2436

REAR

Filtered Exhaust Louvers

Sun shield

FRONT WITHOUT DOOR

79.00

42U

36.00

24.00

TOP Without Sun Shield

85.40

Conduit Gland Plate

38.00RIGHT SIDE

36.00

Roof Sun Shield

REAR WITH OUT DOOR

30

G LGN

LN G LNG

Optional Distribution

NEMA 3RCabinet has insulationForklift Base AND Lift eyes Up to 283CFM Thermostatically controlled fan Internal 42U 19" four post rack rails adjustable front to rearOptional distribution Optional bypass Front blanking panels also added to control air flow (not shown)

NOTES:

6U NEMA 3R Enclosure, With Ventilation

KH 4-14-2017Drawing No. 1021 Rev. 1Part Number : HMA241636

36.00

16.00

TOP Without Sun Shield

FRONT Without Door

24.00

Sun shield

6U

REAR Without Door

3 0

GL

GN

LN

GLN

G

4" base

Optional Distribution

NEMA 3RCabinet has insulationOptional Forklift Base AND Lift eyes Optional wall mounting plateUp to 283CFM Thermostatically controlled fan Internal 6U 19" Horizontal four post rack rails adjustable front to rearOptional distribution Optional bypassFront blanking panels also added to control air flow (not shown)Shown with optional 2U UPS and 2U EBM’s

NOTES:

30.30Conduit

Gland Plate

38.00

RIGHT SIDE

36.00

Sun Shield

FRONT

Filtered 6" Fan Pressurizing The

Cabinet

Optional .19" Wall Mounting

Plate

6U 12U 18U 30U 42U

Wall-Mount Enclosures• 4U wall-mount power enclosure• 6U wall/pole mounted, freestanding

convertible enclosure• Wall-mount brackets• Insulated cabinet• Internal UPS mounting plate

2U NEMA 3R Enclosure, With Ventilation Wall Mount

KH 4-12-2017Drawing No. 1020 Rev. 1Part Number : HMA412412WM

24.00

41.00

Front door closed

Right side UPS in Service position Front Door Open UPS in Service position

Right side UPS in Normal position

17.70

Input Output terminal block and bypass

Front Door Open Showing UPS InstalledWall Mount Brackets Atached

NEMA 3RCabinet has insulationWall Mount brackets Up to 283CFM Thermostatically controlled fanInternal UPS Mounting PlateOptional distributionOptional bypassShown with optional 2U UPS

NOTES:

2U NEMA 3R Enclosure, With Ventilation Wall Mount

KH 4-12-2017Drawing No. 1020 Rev. 1Part Number : HMA412412WM

24.00

41.00

Front door closed

Right side UPS in Service position Front Door Open UPS in Service position

Right side UPS in Normal position

17.70

Input Output terminal block and bypass

Front Door Open Showing UPS InstalledWall Mount Brackets Atached

NEMA 3RCabinet has insulationWall Mount brackets Up to 283CFM Thermostatically controlled fanInternal UPS Mounting PlateOptional distributionOptional bypassShown with optional 2U UPS

NOTES:

Standard OptionsConstruction:• Stainless Steel (304/316L)• Custom paint- user specified, standard RAL colors• Front door only• User defined security, access control and door handles• EMI/RFI attenuating gasketing• Seismic mounting and vibration attenuation• Sliding and fixed shelves• Sub-panel for din-rail mounted equipment• Interior lighting and door window kits

Thermal Management• Full interior Insulation–R7• Full coverage sunscreen, door drip shields• 10” ventilation fan- 306 CFM• Air conditioning- user or application defined BTU and

operating voltage• Mission critical venting–mechanical louvers,

H2 sensor and controls (required for Type 4/X, sealed enclosure applications)• Heater• Thermostat or timer• 18-inch leg stands or heavy duty casters

Power Input/Output• Custom power distribution din rail• Main power disconnect/circuit breaker• Terminal blocks for main power input/output and accessory power• Terminal blocks and relays for dry contact communication• Convenience receptacles–user specified

Page 3: N1 Critical Technologies is proud to offer · Industrial-Rated Enclosures. for backup power systems in challenging or ... • 2 sets/4 post heavy duty mounting rails for rack mounted

Custom Options*Construction:• NEMA Type 12, 3/R, 4/X and IP ratings

• User or application-defined dimensions; custom H x W x D

• Carbon, stainless steel (304/316L) and aluminum; user andapplication-specified gauges

• One, two or multi-door front, or dual access withdoors front and rear

• Marine-grade and corrosion resistant coatings

• Fixed-mount equipment installation including large 3P UPS

• DC power systems–chargers and custom battery solutions

• Battery rack-mounting

* All “Standard Options” listed on inside page can be selectedas part of a full custom enclosure

(877) [email protected]

www.n1critical.com • www.lithium-ion-ups.com211 N. Parker Drive, Janesville, WI 53545