63
X 0 . 1 6 X0 . 15 X 0 .1 3 X 0 .1 4 X0 .1 2 X 0 . 1 0 X 0 .1 1 X0 .9 X 0 . 1 X 0 . 2 X 0 .6 X 0 .7 X 0 .5 X0 . 4 X0 . 3 1 6 P W 1 F F 1 F F 2 PW2 + - X 2 0 A l ar m 3 4 + - 6 5 2 1 1 6 K1 M B- 1 6 U 5 L - 1 0 3 6 8 1 P E PP E R L + FU C H S D 6 83 0 7 M a nn h ei m 8 4 1 08 Y 1 0 1 02 8 5 6 1 60 30 3 1 1 D 10 1 D 10 0 D 1 0 D 4 PROCESS AUTOMATION HAZ-RTP adapted to Honeywell 1756 Rack IO Modules PROCESS AUTOMATION

N O HAZ-RTP adapted to I O Honeywell 1756 Rack IO …€¦ · Intrinsic safety termination assemblies ... The power source has a redundant design, ... and the PCB B: Sb/Bro

Embed Size (px)

Citation preview

X0.

16X

0.15

X0.

13

X0.

14

X0.

12

X0.

10

X0.

11

X0.

9

X0.

1

X0.

2

X0.

6

X0.

7

X0.

5X

0.4

X0.

3

1

6

PW

1

FF1

FF2P

W2

+

-X

20

Ala

rm3

4 +

-6

5

21

1

6

K1

MB

-16U

5L-1

0368

1P

EP

PE

RL+

FUC

HS

D68

307

Man

nhei

m

84

108

Y1

0102

8 5

6 1 60

30

31

1

D10

1

D10

0

D10D

4

PROC

ESS

AUTO

MATIO

N HAZ-RTP adapted to

Honeywell 1756 Rack IO Modules

PROC

ESS

AUTO

MAT

ION

Table of contents

Page

1. General Description.................................................................1- 0

2. TC/TK-IAH061 Application (6 AI)..............................................2- 0

3. TC/TK-IAH161 Application (16 AI)............................................3- 0

4. TC/TK-OAV081 Application (8 AO) ...........................................4- 0

5. TC/TK-IDX161 Application (16 DI).............................................5- 0

6. TC/TK-IDD321 Application (32 DI) ............................................6- 0

7. TC/TK-ODX161 Application (16 DO) .........................................7- 0

8. TC/TK-ODD321 Application (32 DO).........................................8- 0

HART Integration to 1756 Rack IO Modules

9. TC/TK-HAI081 Application (8 AI)...............................................9- 0

10. TC/TK-HAO081 Application (8 AO) .........................................10- 0

11. Accessories............................................................................11- 0

NEW !

NEW !

1. General Description

Page Intrinsic safety termination assemblies...............................................1- 1 Motherboard for 16 modules ..............................................................1- 3 Motherboard for 8 modules ................................................................1- 4 Installation instructions.......................................................................1- 5 Power supply block diagram ..............................................................1- 6

1- 0

Hazardous Area Remote Termination Panels With Galvanic Isolators

Honeywell 1756 Rack IO Modules • I/O card number • Signal type

P+F Motherboard • Order name • Part No. • Drawing No.

Description • Module • Motherboard • Dimensions

TC/TK-IAH061 (6 AI)

• HAZ-RTP-IAH061-118251 • Part No. 118251 • Drawing No. 36-7459_

Module: • type KFD2-STC4-Ex1, single channel, (AI) Motherboard: • 6 modules (6 channels) • 1 D-SUB 25 pin, female system connector • 2 HART 26 pin, male connector Dimensions (wxhxd) : • 165x150x150 mm

• HAZ-RTP-IAH161S-107755 • Part No. 107755 • Drawing No. 36-7282_

Module: • type KFD2-STC4-Ex1, single channel, (AI) Motherboard: • 16 modules (16 channels) • 1 D-SUB 37 pin, female system connector • 2 HART 26 pin, male connector Dimensions (wxhxd) : • 325x150x150 mm

• HAZ-RTP-IAH161-123894 • Part No. 123894 • Drawing No. 36-7527_

Module: • type KFD2-UT-Ex1, single channel, (AI) Motherboard: • 16 modules (16 channels) • 1 D-SUB 37 pin, female system connector Dimensions (wxhxd) : • 325x150x150 mm

TC/TK-IAH161 (16 AI)

• HAZ-RTP-IAH161H-105268 • Part No. 105268 • Drawing No. 36-7220_

Module: • type KFD2-STC4-Ex2, dual channel, (AI) Motherboard: • 16 modules (32 channels) • 1 D-SUB 37 pin, female system connector Dimensions (wxhxd) : • 325x150x150 mm

• HAZ-RTP-OAV081H-105269 • Part No. 105269 • Drawing No. 36-7223_

Module: • type KFD2-SCD-Ex1.LK, single channel, (AO) Motherboard: • 8 modules (8 channels) • 1 D-SUB 25 pin, female system connector • 2 HART 26 pin, male connector Dimensions (wxhxd) : • 165x150x150 mm

TC/TK-OAV081 (8 AO)

• HAZ-RTP-OAV081-105289 • Part No. 105289 • Drawing No. 36-7250_

Module: • type KFD2-CD-Ex1.32, single channel, (AO) Motherboard: • 8 modules (8 channels) • 1 D-SUB 25 pin, female system connector Dimensions (wxhxd) : • 165x150x150 mm

TC/TK-IDX161 (16 DI)

• HAZ-RTP-IDX161-105281 • Part No. 105281 • Drawing No. 36-7224_

Module: • type KFD2-SR2-Ex2.2S, dual channel, (DI) Motherboard: • 8 modules (16 channels) • 1 D-SUB 37 pin, female system connector Dimensions (wxhxd) : • 165x150x150 mm

TC/TK-IDD321 (32 DI)

• HAZ-RTP-IDD321-105270 • Part No. 105270 • Drawing No. 36-7226_

Module: • type KFD2-SRA-Ex4, four channel, (DI) Motherboard: • 4 modules (32 channels) • 1 D-SUB 37 pin, female system connector Dimensions (wxhxd) : • 165x150x150 mm

TC/TK-ODX121 (16 DO)

• HAZ-RTP-ODX121-118258 • Part No. 118258 • Drawing No. 36-7461_

Module: • type KFD2-SL2-Ex2.B, dual channel, (DO) Motherboard: • 8 modules (16 channels) • 1 D-SUB 37 pin, female system connector 1Dimensions (wxhxd) : • 165x150x150 mm

TC/TK-ODD321 (32 DO)

• HAZ-RTP-ODD321-105271 • Part No. 105271 • Drawing No. 36-7227_

Module: • type KFD2-SL2-Ex2.B, dual channel, (DO) Motherboard: • 8 modules (16 channels) • 1 D-SUB 37 pin, female system connector 1Dimensions (wxhxd) : • 165x150x150 mm

TC/TK-HAI081 (8 AI)

• HAZ-RTP-HAI081-127742 • Part No. 127742 • Drawing No. 36-7590_

Module: • type KFD2-STC4-Ex1, single channel, (AI) Motherboard: • 8 modules (8 channels) • 1 D-SUB 25 pin, female system connector • 2 HART 26 pin, male connector Dimensions (wxhxd) : • 165x150x150 mm

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\Assignment table-B.doc

1-1

Hazardous Area Remote Termination Panels With Galvanic Isolators

Honeywell 1756 Rack IO Modules • I/O card number • Signal type

P+F Motherboard • Order name • Part No. • Drawing No.

Description • Module • Motherboard • Dimensions

TC/TK-HAO081 (8 AO)

• HAZ-RTP-HAO081-132002 • Part No. 132002 • Drawing No. 36-7632_

Module: • type KFD2-SCD2-Ex1.LK, single channel, (AO) Motherboard: • 8 modules (8 channels) • 1 D-SUB 25 pin, female system connector • 2 HART 26 pin, male connector Dimensions (wxhxd): • 165x150x150 mm

----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\Assignment table-B.doc

1-2

The HAZardous Area Remote Termination Panel (HAZ-RTP…) is designed for 16 or 8 KF-modules. Power feed and system connector to Honeywell 1756 Rack IO Modules are integrated in the motherboard, which results in noticeable space savings the interface cabinet. The power source has a redundant design, increasing the reliability of the system. The operating status of the power supply is monitored and reported via LEDs and relay output. (Dry contact) The KF modules are interfaced to the motherboard himself by using 2- to 6- pin coded cable connectors (FSY…). The motherboard configuration is mounted on a stable metal plate. There are two retainers on the back for mounting the board quickly and easily to a standard DIN rail in accordance with EN 50022. 1. Model with 16 modules

22.08.02 Datum S TD

Dept.: PA-VP Sheet 1

from 1

PEPPERL+FUCHS Mannheim-Schönau

Off. In ch.

contr. techn.

contr. Norm

Replaces :

Scale:

Up date:

HAZ-RTP…(Motherboard) General Description

Terminal strip (removable) for redundant power supply and power monitoring (Option: LB/SC monitoring)

Connector for HART-Multiplexer (Option)

Metal base plate with integrated brackets for mounting on DIN rail

Main board Adapter board with customer specified system plug to Honeywell 1756 Rack IO Modules

Cable connector (FSY...) between the modules and the PCB

B: Sb/Bro 26.03.04 Xxxxx / 36-xxxx

No. Word

Label carrier

1- 3

2. Model with 8 Modules

24.10.00 Datum S TD

Dept.: PA-VP Sheet 1

from 1

PEPPERL+FUCHS Mannheim-Schönau

Off. In ch.

contr. techn.

contr. Norm

Replaces :

Scale:

Up date:

HAZ-RTP…(Motherboard) General Description

Label carrier

Terminal strip (removable) for redundant power supply and power monitoring (Option: LB/SC monitoring)

Connector for HART-Multiplexer (Option)

Metal base plate with integrated brackets for mounting on DIN rail

Main board

Adapter board with customer specified system plug to Honeywell 1756 Rack IO Modules

Cable connector (FSY...) between the modules and the PCB

B: Sb/Bro 26.03.04 Xxxxx / 36-xxxx

No. Word

1- 4

Mounting instructionsPEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

for HAZ-RTP...

Module x

Module x

Module x

Module x

Module 2

Module 4

Module 3

Module 1

10 11 12 7 8 9

X0.21. . . . .6

X0.11. . . . .6

X0.3

7 8 9 10 11 12

7 8 9 10 11 12

1. . . . .6X0.14

1. . . . .61. . . . .6

X0.12X0.13

1. . . . .6X0.15

10 11 12 7 8 9

10 11 12 10 11 12 7 8 9

7 8 9

4 5 6 4 5 6

1 2 3 1 2 3

xxxxxx / 36-xxxxReplaces:

36-9159A1Up date:

14.02.00

Dept.:

Date

Scale:

DN

PA-VP

02.02.04Sch/Bro

S

No.in ch.TD Off.

vB

of- 1

contr.

Sheet

Normcontr.Sb/vB

techn.

1

X0.16

4 5 1 2

X1

MB-H

O-XXX-XXXXX

CR

US

3719

HA

Z-RTP-XXX

Y1PW

2

Alarm1

24

35

6

X20 + -

+ - FF2

FF1

PW1

1. Take away first and last module. Operate the screw to fix the board on to the DIN rail.

Installations instructions2. Turn the part as shown the stopper!

3. Set the board on the DIN rail. Turn the screw as shown till the board is fixed.(Arrows are showing direction how to turn for fixing the board)

X

152

1. . . . .6 7 8 9 10 11 12

Module 4

Module 3

Module 2

Module 1

97.5150

X0.1X0.2

1. . . . .61. . . . .6

X0.3

10 11 12 7 8 9

7 8 9 10 11 12

Module x

Module x

Module x

Module x

X0.151. . . . .6

7 8 9 10 11 12

X0.12X0.13

1. . . . .61. . . . .6

X0.14

7 8 9 10 11 12

7 8 9 10 11 12

X0.16

4 5 6 1 2 3

4 5 6 1 2 3

Alarm5+ - 6

34

+ -2

X201

PW2

FF2

PW1

FF1

19

MB-H

O-XXX-XXXXX

37

C HA

Z-RTP-XXXX1

R

US

Y1

4 5 1 2

1- 5

2. TC/TK-IAH061 Application (6 channels AI current 4 … 20 mA) Page HAZ-RTP-IAH061H-118251 ........................................................................ 2- 1 Documentation ............................................................................................. 2- 2

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\2-TC-IAH061-B.doc

2- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

20.02.03

Dept.:

Date TD

KT

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6190A

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

1 : 5

TC/TK-IAH061 AI current 4 ... 20 mA6 ch.

LOOP-DIAGRAM (1-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

2-, 3-wire Transmitter(0/4 ... 20 mA)

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

HART-Multiplexer

TC-IAH0618 point high-levelanalog input module

KFD2-... (Module see table)

Module

KFD2-STC4-Ex1AI, current

Signal

HAZ-RTP-IAH061H-118251

Motherboard System cable *1) HART communication *2)

yesHAZ-25xMx

Option

APPLICATION FOR

Honeywell1756 Rack IO Modules

Sb.

Power supply 24 VDC (redundant)Alarm (dry conntact NC)

4 5

6

1 2

3

4 5

6

4 5

6

1 2

3

1 2

3

7 8

9

10 1

1 12

X0.6

1. .

. . .6

10 1

1 12

7

8

9

1. .

. . .6

7 8

9

10 1

1 12

1. .

. . .6

F1 (T

2A)

+

- 4F2 (T

2A)

PW2

PW1

FF1X0

.8

1FF2

Alar

m3

2

X0.7

+

-5

6

X20

7 8

9

X3X2

7 8

9

X0

.31.

. . .

.6

10 1

1 12

7

8

9

HA

Z-R

TP-X

XXXX

10 1

1 12

7

8

9

1. .

. . .6

10 1

1 12

1. .

. . .6

MB-

HO

-XXX

XX

X0.5

US C

X0.4 X1

7 8

9

10 1

1 12

1. .

. . .6

10 1

1 12

1. .

. . .6

X0.2

AP-XX-XXXXX

X0.1

26251 2

26251 2

Module 8

Module 7

Module 5

Module 6

Module 4

Module 2

Module 3

Module 1

13 25141

from X3additional motherboard(ch. 9 ... 16)

Cable type K-HM26

Multiplexer

TC-IAH061

i RTN-0

Cable type K-HM26

System cableX1

RTN

HART

RTNRTN

RTN

-

3

CH 1+ i IN-0

CH 1

3

+1-2

HART

R

7-

9+8+

+6-5

Power Rail(Power supply)

*1) ... *2) see table

165

150

+1-2

(dry cont. NC)Alarm

X2

8 channels

CH 6

from second motherboard (X3)

Cable type K-HM26

CH 1

X3

Module 7 and 8 not connected

Channel 7 and 8 not in use

1756 Rack IO Modules

Cable type K-HM26 *2)

System cable *1)

2- 1

Ordering information:

MB-8U2-Y97680

MB-HO-IAH061H-118252KFD2-STC4-Ex1 (AI)

Power supply screw terminals

LEDs for power and power failure

26 pin HART connector male

Alarm screw terminal

6 channels

Motherboard unit Analog Input - HART

KFD0-LC1-8M-99143FSY-L456-Y98836

HAZ-RTP-IAH061H-118251

6 pin male terminals for cable tree FSY....

25 pin female system connector DSUB

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

PEPPERL+FUCHS

8 pieces:

1 piece:1 piece:

AP-01-118253

composed by:1 piece:8 pieces:Basic components:

1 piece:

PW1, PW2, FF1, FF2

X20.1, X20.2F1, F2

X20.3 .... 6X0.1 .... 8X2, X3X1Name

Fuse

Note

FSY cable tree and Label carrier

MB-8U2

Up date:

25.02.02

Cabel tree connection KF-Module-Motherboard

Adapter board Label carrier 1

Dept.:

Date

Scale: 1 : 2 of 2

Sb/vBcontr.techn.

36-7459Axxxxxx / 36-xxxx

Nr.Replaces:

PA-VP

17.03.04Sb/Bro

S TZ

SbOff.

in ch.

Sb

Sheet 1

contr.Norm

Motherboard without modules, adapter board,

HAZ-RTP-IAH061H-118251

Description

Motherboard without modulesKF-Module type (function)

20

1 2 3 4 5 6

1 2 3 4 5 6

X0.7

F1 (T2A)

F2 (T2A)

1. . . . .6

7 8 9 10 11 12 10 11 12

7 8 9

Mod

ule

7

Mod

ule

8

X20

1. . . . .6

PW2

3 + -Alarm

1 2

FF2 + -

4 65

PW1

FF1

X0.8

150

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

Mod

ule

6

Mod

ule

5

7 8 9 10 11 12

125125

Adapter board

165

26 2 26 2

X1

MB-HO-IAH061-118252

7 8 9 10 11 12

HAZ-RTP-IAH061H-118251

1. . . . .61. . . . .6 1. . . . .6

CUS

R

X0.6

X2

X0.5 X0.4

10 11 12 7 8 9 7 8 9

10 11 12

1. . . . .61. . . . .6 1. . . . .6X0.2

1325

X0.3

AP-0

1-11

8253

X3

114

X0.1

7 8 9 10 11 12

7 8 9 10 11 12

1 2 3 4 5 6

Label carrier 1

2- 2

3 39

43

4748

46

4544

4142

40

3738

3536

34

31

3332

2930

28

27

2526

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

9 RTN0V 52 ... 54 24 ... 2624 ... 26

PEPPERL+FUCHS

copy

right

acc

ordi

ng to

DIN

34

metal mounting plateGround

RB-V2

PF1PF2

LB/SC

RB-V1

HAZ-RTP-IAH061H-118251

Analog Input - HART6 channels

Motherboard unit

57

5960

58

56

55

18

2019

23

2122

1716

8

11

1312

910

76

RTNShell10

1

+ 24VDC

8

23

1

7

654

32

2

6

6

45

3

5

1

654

49 ... 518

14, 151 ... 5

7

242322

1318

14, 151 ... 5

17

21

1920

6

12

1817

5

16

11

16

15

RTN-513

IN-514

8 channels on board8 channels extern

Scale:MB-8U2 - : - of 2

XXXXXX / 36-XXXX

in ch.

Replaces:

Off.Sb

9 ... 16

1 ... 8

PA-VP

17.03.04Sb/Bro

Up date:

Dept.:

25.02.02

Date

No.

TD

Sb

S

X2

X3

36-7459A

contr.techn.

Sb

Sheet 2

contr.Norm

1 ... 8

P+F

Channels distribution:

common for 8 channels

-5+6

V1/PR

-23

+1

R

HART8+9+

7-

14, 1524 ... 26

1 ... 5

DCS

X3

x

RTN-x

X1IN-x

Loop

44 RTN-13

3

4

12

6

45

6

23

1

54

1

32

56

4

232

6

1

5

3

15

4

1314 10

121110

9

IN-412

RTN-411

IN-38

RTN-37

89

7

8

2

65 7

RTN-2

IN-26

5

IN-14

X0.

HART

V1/PR

Module

-2

-5+6

3

Field+1

8+ 5

1

R 9+

3

12

6

FSY-7- 4

2 6

1

3

Y11

X3

IN-02

X1X2 Ch.

RTN-01

Module and cable typesKFD2-STC4-Ex1FSY-L456-98837FSY- Cable type:

KF-Module terminal no.:87

9

AI Module type:

Module 7 and 8 not connected

2- 3

3. TC/TK-IAH161 Application (16 channels AI current 4 … 20 mA) Page HAZ-RTP-IAH161S-107755......................................................................... 3- 1 Documentation ............................................................................................. 3- 2 HAZ-RTP-IAH161T-123894 ......................................................................... 3- 5 Documentation ............................................................................................. 3- 6 HAZ-RTP-IAH161H-105268 ........................................................................ 3- 8 Documentation ............................................................................................. 3- 9

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\3-TC-IAH161.B.doc

3- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

20.02.03

Dept.:

Date TD

KT

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

+

-

X0.2

10 1

1 12

Module 15

1. .

. . .6

7 8

9

X0.1

1

7 8

9

Module 6

4 5

6

1 2

3

4 5

6

7 8

9

10 1

1 12

1. .

. . .6

1 2

3

4 5

6

1 2

3

4 5

6

4 5

6

1 2

3

1 2

3

1 2

3

4 5

6

X0.1

6

10 1

1 12

7

8

9

1. .

. . .6

Module 1

150

Y1

7 8

9

10 1

1 12

10

11

12

Module 2

Module 3

7 8

9

10 1

1 12

Module 5

Module 4

10 1

1 12

7

8

9

1. .

. . .6

X0.1

51.

. . .

.6X0

.14

1. .

. . .6

X0.1

21.

. . .

.6X0

.13

1 2

3

4 5

6

1 2

3

4 5

6

7 8

9

10 1

1 12

10

11

12

10 1

1 12

7

8

9

Module 7

Module 8

7 8

9

10 1

1 12

Module 9

Module 10

7 8

9

10 1

1 12

1. .

. . .6

X0.1

01.

. . .

.6X0

.9X0

.81.

. . .

.6X0

.71.

. . .

.6

7 8

9

7 8

9

10 1

1 12

Module 12

Module 11

10 1

1 12

7

8

9

Module 14

Module 13

10 1

1 12

7

8

9

X0.4

1. .

. . .6

1. .

. . .6

X0.6

1. .

. . .6

X0.5

X0.3

1. .

. . .6

Alar

m21

325

X20

Module 16

PW2

X0.1

1. .

. . .6 FF

1

PW1

FF2

+

-5

63

4

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

7 8

9

10 1

1 12

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

36-6189A1

AP-XX-XXXXX

HA

Z-R

TP-X

XXXX

MB-

HO

-XXX

XX

CUS

3719

X2

21

X1201

2625

Multiplexer

TC-IAH161

i RTN-0

Cable type K-HM26

System cable

X2

X1

RTN

HART

RTNRTN

RTN

-

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

1 : 5

TC/TK-IAH161 AI current 4 ... 20 mA16 ch.

Alarm (dry conntact NC)Power supply 24 VDC (redundant)

LOOP-DIAGRAM (1-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

2-, 3-wire Transmitter(0/4 ... 20 mA)

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

HART-Multiplexer

TC-IAH16116 point high-levelanalog input module

3

CH 1+ i IN-0

CH 1

KFD2-... (Module see table)

Module

KFD2-STC4-Ex1

KFD2-UT-Ex1

AI, current

AI, current

Signal

HAZ-RTP-IAH161S-107755

HAZ-RTP-IAH161T-123894

Motherboard System cable *1) HART communication *2)

yes

noHAZ-37xMx

HAZ-37xMx

Option

3

+1-2

HART

R

7-

9+8+

+6-5

Power Rail(Power supply)

Sb.

*1) ... *2) see table

(dry cont. NC)Alarm

+1-2

-1

+3-2 8+

7-

+4

Power Rail(Power supply)

+3

-1-2

No HART-communication

+4

...STC4-Ex1

...UT-Ex1

APPLICATION FOR

Honeywell1756 Rack IO Modules

1756 Rack IO Modules

Cable type K-HM26 *2)

System cable *1)

3- 1

Motherboard without modules, adapter board,

HAZ-RTP-IAH161S-107755

Description

Adapter board Label carrier 1

Motherboard without modulesKF-Module type (function)

6 pin male terminals for cable tree FSY....

37 pin female system connector DSUB

Cabel tree connection KF-Module-Motherboard

FSY cable tree and Label carrier

AP-0

1-10

7756

325

10 11 12 7 8 9

1 2 3 4 5 6

16 channels - one pick-offHAZ-RTP-IAH161S-107755

Basic components:

composed by:1 piece:

1 piece:1 piece:

PW1, PW2, FF1, FF2

16 pieces:

Power consumption

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

1 piece:16 pieces:

X20.3 .... 6X20.1, X20.2F1, F2

X0.1 .... 16

Name

X2X1

AP-01-107756KFD0-LC1-16M-99144FSY-L450-98833

Motherboard unitAnalog Input - HART

Ordering information:

MB-16U5L-103681

MB-HO-IAH161S-107754KFD2-STC4-Ex1 (AI)

Power supply screw terminals

LEDs for power and power failure

26 pin HART connector male

Alarm screw terminal

24VDC/0,84A/20W

Note

Fuse

1. . . . .6

1 2 3 4 5 6

10 11 12 7 8 9

Mod

ule

15

X0.15

7 8 9 10 11 12

1 2 3 4 5 6

150

X0.161. . . . .6

Y1

Mod

ule

16

HAZ-RTP-IAH161S-107755

MB-HO-IAH161S-107754

Adapter board

1. . . . .6X0.12

7 8 9 10 11 12

CR

US

3719

1. . . . .6

10 11 12 7 8 9

10 11 12

1. . . . .6X0.14

Mod

ule

14

X0.13

7 8 9 M

odul

e 13

Mod

ule

12

X2 21X1201

2625

1. . . . .6

7 8 9 7 8 9 10 11 12 10 11 12

X0.101. . . . .6

X0.11M

odul

e 11

1. . . . .6X0.9

Mod

ule

10

Mod

ule

9

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

xxxxxx / 36-xxxx

36-7282Up date:

Dept.:

Date

27.09.00

MB-16U5L Scale:

Sb/BK16.12.03

PA-VP

S

Replaces:Nr.in ch.TZ

SBOff.SB

of1 : 2 3

Normcontr.

Sheet

Sb/vB

techn.contr.

1

Alarm

1. . . . .6

7 8 9

Mod

ule

2

10 11 12

X0.2

10 11 12 7 8 9

1. . . . .6

10 11 12 7 8 9

X0.5

10 11 12 7 8 9

1. . . . .6

Mod

ule

7

10 11 12 7 8 9

10 11 12

X0.71. . . . .6

X0.8

7 8 9

Mod

ule

8

1. . . . .6X0.6

Mod

ule

6

21

7 8 9 10 11 12

1. . . . .6X0.4

Mod

ule

5

Mod

ule

4

1. . . . .6X0.3

Mod

ule

3

Label carrier 1

PW2

+ -43 5

X20 + -

6

FF2

10 11 12 7 8 9

1. . . . .6X0.1

FF1

PW1

Mod

ule

1

3- 2

16 channels - one pick-offHAZ-RTP-IAH161S-107755

X2

6

7

8

9

10

11

12

13

753

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

PEPPERL+FUCHSMotherboard unitAnalog Input - HART

1 79

8

7

8

23

18384

82

7

56

42324

22

32

8180

R8

6

5

2 77

654

212019

63 78

R7

1

56

76

1718

5

4 16

R6

4 4

3 3

4

12

6

7374

1554

4

1413

R5

6 12

23

17172

70

54

1110

R4

2

1 67

32

6968

56

489

7

R3

2

23

6566

6

1

56

64

5R2

FSY-

-2 8+

V1/PR

-5+6

3

1

9+R

Module

HART

Field+1 7-

5 2

13 6321

6

6261

3 R1

X0. Y14 1

RTN10

Scale: - 3of

17.07.03

TZ

Sb

Up date:

Dept.:Sb/vB

PA-VP

Date

25.09.00

S

2827

RTNRTN

36-7282xxxxxx/36-xxxx

Sb/vBcontr.techn.

Replaces:Nr.in ch.Off.Sb

2Sheet

contr.Norm

i IN-718

9 RTN

i RTN-717

i IN-6

i RTN-6

16

15

i IN-5

i RTN-513

14

i RTN-13

i RTN-4

12 i IN-4

11

i RTN-3

i IN-38

7

i RTN-2

6

5

i IN-2

4 i IN-1

Module and cable types

FSY- Cable type:AI Module type:

KF-Module terminal no.:

2 i IN-0

Ch

i RTN-0

X1

1 FSY-L450-98833

87

9

KFD2-STC4-Ex1

Y1: 25

3- 3

993

HAZ-RTP-IAH161S-10775516 channels - one pick-offAnalog Input - HARTMotherboard unit

R14

R15

R16

R = 250 OHM

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

52 ...54X20: 4,6(0V)

copy

right

acc

ordi

ng to

DIN

34

PEPPERL+FUCHS

PF2PF1LB/SCV2

metal mounting plateGround

V157

5960

58

56

55

1 103

X20: 3,5(+ 24VDC)

1616

23

1

49 ... 51

107108

106

1515

56

4

32

4748

46

105104

2 101

14

654

143

454443

102

13

1

56

13

4

100

4142

40

V1/PR

contr.Norm

Scale: - of

Up date:

Dept.:

Date

27.09.00

Shell24 ... 26

36-7282Replaces:

in ch.Off.

17.07.03

PA-VPSb/vB

Nr.

TZS

Sb Sb

xxxxx/ 36-xxxx Sheet

Sb/vBcontr.techn.

common for 16 channels

24 ... 2614, 151 ... 5

3

3

Loop i IN-1536

1 ... 514, 15

3523

i RTN-15

3 R 9+

+6-5

+1 HART-2

7-8+

xR

X2

x

X1

x

DCS

34

3322

i RTN-14

i IN-14

32

3121

i RTN-13

i IN-13

R9

R10

R11

R12

R13

284

1111

12

12

6

12

54

9798

393837

6

23

1

54

36

9596

94

3534

1

32

56

4

91

9392

3233

31

1010

23

6

1

5

9089

30

88

29

ModuleField

5 26

9 9321

6

878685

27

X0.FSY-4

Y125

i RTN-921

30

2920

i IN-12

i RTN-12

26

2519

i IN-11

i RTN-11

24

2318

i RTN-10

i IN-10

2217

i IN-9

1620 i IN-8

19

X1X2 Ch.

i RTN-8Y1: 22

3- 4

Motherboard without modules, adapter board,

HAZ-RTP-IAH161T-123894

Description

Adapter board Label carrier 1

Motherboard without modulesKF-Module type (function)

6 pin male terminals for cable tree FSY....

37 pin female system connector DSUB

Cabel tree connection KF-Module-Motherboard

FSY cable tree and Label carrier

AP-0

2-10

7756

325

10 11 12 7 8 9

1 2 3 4 5 6

16 channels - one pick-offHAZ-RTP-IAH161T-123894

Basic components:

composed by:1 piece:

1 piece:1 piece:

PW1, PW2, FF1, FF2

16 pieces:

Power consumption

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

1 piece:16 pieces:

X20.3 .... 6X20.1, X20.2F1, F2

X0.1 .... 16

Name

----X1

AP-02-107756KFD0-LC1-16M-99144FSY-L450-98833

Motherboard unitAnalog Input

Ordering information:

MB-16U5L-103681

MB-HO-IAH161T-123893KFD2-UT-Ex1 (AI)

Power supply screw terminals

LEDs for power and power failure

Alarm screw terminal

24VDC/0,84A/20W

Note

Fuse

----

1. . . . .6

1 2 3 4 5 6

10 11 12 7 8 9

Mod

ule

15

X0.15

7 8 9 10 11 12

1 2 3 4 5 6

150

X0.161. . . . .6

Y1

Mod

ule

16

HAZ-RTP-IAH161T-123894

MB-HO-IAH161T-123893

Adapter board

1. . . . .6X0.12

7 8 9 10 11 12

CR

US

3719

1. . . . .6

10 11 12 7 8 9

10 11 12

1. . . . .6X0.14

Mod

ule

14

X0.13

7 8 9 M

odul

e 13

Mod

ule

12

X1201

1. . . . .6

7 8 9 7 8 9 10 11 12 10 11 12

X0.101. . . . .6

X0.11M

odul

e 11

1. . . . .6X0.9

Mod

ule

10

Mod

ule

9

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

xxxxxx / 36-xxxx

36-7527Up date:

Dept.:

Date

05.02.03

MB-16U5L Scale:

Sb/BK16.12.03

PA-VP

S

Replaces:Nr.in ch.TZ

KTOff.SB

of1 : 2 3

Normcontr.

Sheet

Sb/vB

techn.contr.

1

Alarm

1. . . . .6

7 8 9

Mod

ule

2

10 11 12

X0.2

10 11 12 7 8 9

1. . . . .6

10 11 12 7 8 9

X0.5

10 11 12 7 8 9

1. . . . .6

Mod

ule

7

10 11 12 7 8 9

10 11 12

X0.71. . . . .6

X0.8

7 8 9

Mod

ule

8

1. . . . .6X0.6

Mod

ule

6

21

7 8 9 10 11 12

1. . . . .6X0.4

Mod

ule

5

Mod

ule

4

1. . . . .6X0.3

Mod

ule

3

Label carrier 1

PW2

+ -43 5

X20 + -

6

FF2

10 11 12 7 8 9

1. . . . .6X0.1

FF1

PW1

Mod

ule

1

3- 5

16 channels - one pick-offHAZ-RTP-IAH16T-123894

753

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

PEPPERL+FUCHSMotherboard unitAnalog Input

1 79

8

7

8

23

18384

82

7

56

42324

22

32

8180

6

5

2 77

654

212019

63 78

1

56

76

1718

5

4 16

4 4

3 3

4

12

6

7374

1554

4

1413

6 12

23

17172

70

54

1110

2

1 67

32

6968

56

489

7

2

23

6566

6

1

56

64

5

FSY-

-2 8+

+4+3

V1/PR

1

ModuleField-1 7-

5 2

13 6321

6

6261

3

X0. Y14 1

RTN10

Scale: - 3of

19.05.03

TZ

KT

Up date:

Dept.:Sb/KT

PA-VP

Date

05.02.03

S

2728 RTN

RTN

36-7527xxxxxx/36-xxxx

contr.techn.

Replaces:Nr.in ch.Off.Sb Sb

2Sheet

contr.Norm

9 RTN

i IN-7i RTN-7

1817

i IN-6i RTN-6

1615

i IN-5i RTN-513

14

i RTN-13

i RTN-4i IN-412

11

i RTN-387

i IN-3

i RTN-265

i IN-2

4 i IN-1

Module and cable types

FSY- Cable type:AI Module type:

KF-Module terminal no.:

i IN-02

Ch.

i RTN-0

X1

1 FSY-L450-98833

87

9

KFD2-UT-Ex1

Y1: 25

MB-16U5L

3- 6

993

HAZ-RTP-IAH16T-12389416 channels - one pick-off

Motherboard unit

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

52 ...54X20: 4,6(0V)

copy

right

acc

ordi

ng to

DIN

34

PEPPERL+FUCHS

PF2PF1LB/SCV2

metal mounting plateGround

V1

Analog Input

57

5960

58

56

55

1 103

X20: 3,5(+ 24VDC)

1616

23

1

49 ... 51

107108

106

1515

56

4

32

4748

46

105104

2 101

14

654

143

454443

102

13

1

56

13

4

100

4142

40

-1 7-

contr.Norm

Scale: - of

Up date:

Dept.:

Date

05.02.03

Shell

36-7527Replaces:

in ch.Off.

19.05.03

PA-VPSb/KT

Nr.

TZS

KT Sb

xxxxx/ 36-xxxx Sheet

contr.techn.

Sb

common for 16 channelsV1/PR

+3+4

-2 8+ 2

1

3

3

Loop for channel 1

3635 i RTN-15

i IN-15

X1 DCS

3433 i RTN-14

i IN-14

3231 i RTN-13

i IN-13

284

1111

12

12

6

12

54

9798

393837

6

23

1

54

36

9596

94

3534

1

32

56

4

91

9392

3233

31

1010

23

6

1

5

9089

30

88

29

ModuleField

5 26

9 9321

6

878685

27

FSY- X0.4

Y125

i RTN-921

3029

i IN-12i RTN-12

2625 i RTN-11

i IN-11

2423 i RTN-10

i IN-10

22 i IN-9

i IN-82019

X1 Ch.

i RTN-8Y1: 22

MB-16U5L

3- 7

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

20.02.03

Dept.:

Date TD

KT

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6189A2

Multiplexer

TC-IAH161

RTN-0

Cable type K-HM26

System cable

X2

X1

RTN

HART

RTNRTN

RTN

-

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

1 : 5

LOOP-DIAGRAM (2-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

2-wire Transmitter(0/4 ... 20 mA)

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

HART-Multiplexer

TC-IAH16116 point high-levelanalog input module

-3

+1CH 1

+ IN-0

CH 1

KFD2-... (Module see table)

Module

KFD2-STC4-Ex2AI, current

Signal

HAZ-RTP-IAH161H-105268

Motherboard System cable *1) HART communication *2)

yesHAZ-37xMx

Option

Power Rail(Power supply)

Sb.

13 1

4 15

10

11

12

1 2

3

1 2

3

1 2

3

13 1

4 15

7 8

9

10 1

1 12

Module 8

Module 4

Module 5

Module 3

Module 6

Module 7

4 5

6

4 5

6

4 5

6

13 1

4 15

10

11

12

7 8

9

7 8

9

10 1

1 12

7

8

9

13 1

4 15

7 8

9

10 1

1 12

10

11

12

7 8

9

13 1

4 15

13

14

15

Module 2

Module 1

7 8

9

10 1

1 12

10

11

12

7 8

9

13 1

4 15

13

14

15

1. .

. . .6

X1H

AZ-

RTP

-XXX

XX

65

23

41

F1 (T

2A)

FF1

X0.7

1. .

. . .6

X0.8

PW1

X0.6

1. .

. . .6

FF2

PW2

+

- +

-F2

(T2A

)Al

arm

US C

X0.4

1. .

. . .6

X0.5

1. .

. . .6

X0.3

1. .

. . .6

19 37

X20

165

MB-

HO

-XXX

XX

X2

AP-XX-XXXXX

X0.1

1. .

. . .6

X0.2

1. .

. . .6

1 20

22625

1

Power supply 24 VDC (redundant)Alarm (dry conntact NC)

8+7-

11+10-

12+-6

+4

-3

+1

HART

R

HART

R 9+

-5

+4CH 2

- RTN-1+ IN-1

CH 2

*1) ... *2) see table

(dry cont. NC)Alarm

150

TC/TK-IAH161 AI current 4 ... 20 mA16 ch.

APPLICATION FOR

Honeywell1756 Rack IO Modules

1756 Rack IO Modules

System cable *1)

Cable type K-HM26 *2)

3- 8

MB-HO-IAH161H-102519

Adapter board

165

7 8 9

1. . . . .6

7 8 9 10 11 12 10 11 12

HAZ-RTP-IAH161H-105268

FSY cable tree and Label carrier

Cabel tree connection KF-Module-Motherboard

37 pin female system connector DSUB

6 pin male terminals for cable tree FSY....

KF-Module type (function)Motherboard without modules

Label carrier 1 Adapter board

Description

HAZ-RTP-IAH161H-105268

Motherboard without modules, adapter board,

HAZ-RTP-IAH161H-105268

Power consumption

8 pieces:

PW1, PW2, FF1, FF2

1 piece:1 piece:

1 piece:composed by:

Basic components:

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

8 pieces:1 piece:

Name

X0.1 .... 8

F1, F2X20.1, X20.2X20.3 .... 6

X2X1

FSY-K123L456-99154KFD0-LC1-8M-99143AP-HO-102520

Analog Input - HARTMotherboard unit

16 channels

24VDC/0,84A/20W

Alarm screw terminal

26 pin HART connector male

LEDs for power and power failure

Power supply screw terminals

KFD2-STC4-Ex2 (AI)MB-HO-IAH161H-102519

MB-8U2-Y97680

Ordering information:

Fuse

Note

Mod

ule

8

Mod

ule

7

Mod

ule

6

Mod

ule

5X20

+ -

10 11 12 7 8 9

150

1. . . . .6

PW2

FF2

Alarm21 3

FF1

PW1X0.8

7 8 9 10 11 12 10 11 12

7 8 9

X0.61. . . . .61. . . . .6

F2 (T2A) + -

4 5 6

X0.7

F1 (T2A)

1. . . . .6X0.5

CR

US

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

20

xxxxxx / 36-xxxx

36-7220A

25.02.00

Date

Dept.:

Up date:

MB-8U2 Scale:

vB

TZ

07.09.06

PA-VP

S

Replaces:Nr.in ch.

vB SbOff.

of1 : 2 2

Norm

Sheet

contr.techn.contr.Sb

1

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

7 8 9 10 11 12

7 8 9 10 11 12

X0.11. . . . .6

125X2

26 2

X1

7 8 9 10 11 12

1. . . . .6X0.4 X0.3

1. . . . .6X0.2

AP

-HO

-102

520

Label carrier 1

3- 9

76

X2

1 ... 5

24 ... 2614, 15

IN-1

X1

RTN-0

RTN-1

IN-0

DCS

common RTN for 16 channels

LB/SC

Groundmetal mounting plate

AI Module type:

89

12

1011

7

KF-Module terminal no.:

FSY- Cable type:KFD2-STC4-Ex2FSY-K123L456-99154

Module and cable types

49 ... 51

56

55

585960

57V1

PF1PF2

V2

52 ... 54

(+ 24VDC)

(0V) X20: 4,6

X20: 3,5

16 channelsAnalog Input - HARTMotherboard unit

HAZ-RTP-IAH161H-105268Up date: 07.09.06

vBxxxxxx / 36-xxxx

Replaces:

RTNRTNRTNRTN

IN-5

RTN-5

IN-11

RTN-11

IN-15

RTN-15IN-14

RTN-14

IN-13

RTN-13IN-12

RTN-12

IN-10

RTN-10

IN-9

RTN-9IN-8

RTN-8

IN-7

RTN-7IN-6

RTN-6

IN-4

RTN-4

IN-3

RTN-3IN-2

RTN-2

IN-1

RTN-1IN-0

RTN-0

28 27 10 9

Shell

copy

right

acc

ordi

ng to

DIN

34un

auth

oriz

ed d

istri

butio

n an

d re

prod

uctio

n pr

ohib

ited

24 ... 2614, 151 ... 5

22

23

20

21

18

19

16

17

12

13

10

11

8

9

7

6

X1

19

21

20

24

23

26

30

29

25

32

31

34

33

36

35

22

15

16

18

17

11

12

14

13

5

6

8

7

3

4

2

1

X2

Loop for channel 1 and 2

P+F

8

7

6

5

4

3

2

1

39

43

4748

46

4544

4142

40

3738

3536

34

31

3332

2930

28

27

2526

2322

8

24

23

56

1

4

2019

7

21

23

56

1

4

1716

6

18

23

56

1

4

1413

5

15

23

56

1

4

1110

4

12

23

56

1

4

87

3

9

23

56

1

4

54

2

6

23

56

1

4

FSY-

2

1

3

23

56

1

Y11

X0.ModuleField

4

in ch.Off. contr. contr.

of

Sheet

Scale:

Dept.:

Date

vB SbSb

36-7220A

25.02.00

Nr.PEPPERL+FUCHS

Normtechn.TZS

PA-VP

2

2

11+-6 R

V1/PR

12+

+4

-3

+18+

R

HART 10-

9+

HART 7-

11+-6 R

V1/PR

12+

+4

-3

+18+

R

HART 10-

9+

HART 7-

Ch.

3- 10

4. TC/TK-OAV081 Application (8 channels AO current 4 … 20 mA) Page HAZ-RTP-OAV081H-105269 ....................................................................... 4- 1 Documentation ............................................................................................. 4- 2 HAZ-RTP-OAV081-105289 ......................................................................... 4- 4 Documentation ............................................................................................. 4- 5

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\4-TC-OAV081-B.doc

4- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

21.02.03

Dept.:

Date TD

KT

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6191A

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

1 : 5

TC/TK-OAV081 AO current 4 ... 20 mA8 ch.

LOOP-DIAGRAM (1-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

HART-Multiplexer

TC-OAV0818 point high-levelanalog output mod.

KFD2-... (Module see table)

Module

KFD2-SCD-Ex1.LK

KFD2-CD-Ex1.32

AO, current

AO, current

Signal

HAZ-RTP-OAV081H-105269

HAZ-RTP-OAV081-105289

Motherboard System cable *1) HART communication *2)

yes

noHAZ-25xMx

HAZ-25xMx

Option

Sb.

Power supply 24 VDC (redundant)Alarm (dry conntact NC)

4 5

6

1 2

3

4 5

6

4 5

6

1 2

3

1 2

3

7 8

9

10 1

1 12

X0.6

1. .

. . .6

10 1

1 12

7

8

9

1. .

. . .6

7 8

9

10 1

1 12

1. .

. . .6

F1 (T

2A)

+

- 4F2 (T

2A)

PW2

PW1

FF1X0

.8

1FF2

Alar

m3

2

X0.7

+

-5

6

X20

7 8

9

X3X2

7 8

9

X0

.31.

. . .

.6

10 1

1 12

7

8

9

HA

Z-R

TP-X

XXXX

10 1

1 12

7

8

9

1. .

. . .6

10 1

1 12

1. .

. . .6

MB-

HO

-XXX

XX

X0.5

US C

X0.4 X1

7 8

9

10 1

1 12

1. .

. . .6

10 1

1 12

1. .

. . .6

X0.2

AP-XX-XXXXX

X0.1

26251 2

26251 2

Module 8

Module 7

Module 5

Module 6

Module 4

Module 2

Module 3

Module 1

13 25141

from X3additional motherboard(ch. 9 ... 16)

Cable type K-HM26

Multiplexer

TC-OAV081

RTN

Cable type K-HM26

System cable

X3

X1

HART

-CH 1

+ IOUT-0

CH 1

Power Rail(Power supply)

?I

Converter, positioner(4 ... 20 mA)

+1-2

?I

+1-2

9R

HART 7-8+

11+10-

-2+1

Power Rail(Power supply)

...SCD-Ex1.LK

...CD-Ex1.32

*1) ... *2) see table

165

150

X2

8 channels

CH 8

from second motherboard (X3)

Cable type K-HM26

CH 1

(dry cont. NC)Alarm

APPLICATION FOR

Honeywell1756 Rack IO Modules

1756 Rack IO Modules

Cable type K-HM26 *2)

System cable *1)

4- 1

MB-HO-OAV081H-103650

Adapter board

165

7 8 9

1. . . . .6

7 8 9 10 11 12 10 11 12

HAZ-RTP-OAV081H-105269

26 pin HART connector male (see Note)6 pin male terminals for cable tree FSY....

25 pin female system connector DSUB

FSY cable tree and Label carrier

Cabel tree connection KF-Module-Motherboard

KF-Module type (function)Motherboard without modules

Label carrier 1 Adapter board

Description

HAZ-RTP-OAV081H-105269

Motherboard without modules, adapter board,

The Pepperl + Fuchs HART multiplexer HMM (master) and HMS (slave) have 16 channels each. In case of connecting this type of board to a HART-muliplexer, two boards can be connected together (to a total of 16 HART channels). The primary board has to be connected to the HMUX using the X3 connector.If more than 8 HART channels are required, a second board can be connected to the primary one. This connection is made using X2 on the primary and X3 on the secondary board.

Analog Output - HART

HAZ-RTP-OAV081H-105269

Power consumptionPW1, PW2, FF1, FF2

8 pieces:1 piece:1 piece:

1 piece:composed by:

Basic components:

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

8 pieces:1 piece:

X2, X3

X20.3 .... 6X20.1, X20.2F1, F2

X0.1 .... 8

Name

Note:

X1

FSY-L456-98837KFD0-LC1-8M-99143AP-HO-103651

8 channels

Motherboard unit

24VDC/0,45A/10,5W

Power supply screw terminals

LEDs for power and power failure

Alarm screw terminal

KFD2-SCD-Ex1.LK (AO)MB-HO-OAV081H-103650

MB-8U2-Y97680

Ordering information:

Note

Fuse

Mod

ule

8

Mod

ule

7

Mod

ule

6

Mod

ule

5

X20

+ -

10 11 12 7 8 9

150

1. . . . .6

PW2

FF2Alarm

21 3

FF1

PW1X0.8

2526

7 8 9 10 11 12 10 11 12

7 8 9

X0.61. . . . .61. . . . .6

F2 (T2A) + -

4 5 6

X0.7

F1 (T2A)

1. . . . .6X0.5

CR

US

X2

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

20

xxxxxx / 36-xxxxReplaces:

1 : 2

36-7223

06.03.00Date

Dept.:

Up date:

MB-8U2 Scale:

vB/KT

TZ

02.04.03

PA-VP

S

Nr.in ch.

vB vBOff.

of 2

Norm

Sheet

contr.techn.contr.Sb/vB

1

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

7 8 9 10 11 12

7 8 9 10 11 12

X0.11. . . . .6

12512 26 2

7 8 9 10 11 12

1. . . . .6

X1

X0.4

1325

X0.31. . . . .6

X3

X0.2

114

AP-H

O-1

0365

1

Label carrier 1

4- 2

2

2

PA-VP

S TZ techn. Norm

PEPPERL+FUCHS Nr.

06.03.00

36-7223

SB Sb/vBSB

Date

Dept.:

Scale:

Sheet

of

contr.contr.Off.in ch.

4

Field Module X0.1

Y1

1

65

32

3

1

2

FSY-

4

1

65

32

6

2

45

4

1

65

32

9

3

78

4

1

65

32

12

4

1011

4

1

65

32

15

5

1314

4

1

65

32

18

6

1617

4

1

65

32

21

7

1920

4

1

65

32

24

8

2223

1

2

3

4

5

6

7

8

56

X1

39

43

4748

46

4544

4142

40

3738

3536

34

31

3332

2930

28

27

2526

Up date: 07.08.02Sb

HAZ-RTP-OAV081H-105269

Analog Output - HART8 channels

Motherboard unit

3

X3

P+F

9

57

13

158

19

159

4

610

10

611

14

1612

20

1613

Shell

RTN

RTN

RTN

RTN

RTN

RTN

RTN

RTN

Ch.

24 ... 2624 ... 26

2019

232122

1718

16

910

131211

78

6

14, 151 ... 5

14, 151 ... 5

X2

Loop

IOUT-7

IOUT-6

IOUT-5

IOUT-4

IOUT-3

IOUT-2

IOUT-1

IOUT-0

X20: 4,6

X20: 3,5

(0V)

(+ 24VDC)

52 ... 54

V2

PF1PF2

V157585960

56

55

49 ... 51

V1/PR

3

12

9R

HART 7-8+

xxxxxx / 36-xxxxReplaces:

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

2425

2223

21

n.c.n.c.

n.c.n.c.

n.c.

Module and cable types

FSY- Cable type:AO Module type:

KF-Module terminal no.:87

9

KFD2-SCD-Ex1.LKFSY-L456-98837

metal mounting plateGround

LB/SC

14, 1524 ... 26

1 ... 5

DCSIOUT-x

X3

x

RTN-x

X1

common for 8 channels

X3

Channel distribution:

8 channels extern

X2

9 ... 16

1 ... 8

1 ... 8

8 channels on board

-2? 8+I

V1/PR

R 9+

+1 HART 7-

4- 3

X1

MB-HO-OAV081-105290

165

7 8 9

1. . . . .6

7 8 9 10 11 12 10 11 12

HAZ-RTP-OAV081-105289

Description

Motherboard without modules, adapter board,

HAZ-RTP-OAV081-105289

Motherboard without modulesKF-Module type (function)

Adapter board Label carrier 1 Cabel tree connection KF-Module-Motherboard

FSY cable tree and Label carrier

25 pin female system connector DSUB

6 pin male terminals for cable tree FSY....

HAZ-RTP-OAV081-105289

Basic components:

composed by:1 piece:

1 piece:1 piece:8 pieces:

PW1, PW2, FF1, FF2

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

1 piece:8 pieces:

Name

X0.1 .... 8X20.3 .... 6

F1, F2X20.1, X20.2

----X1

AP-HO-105291KFD0-LC1-8M-99143FSY-L450-98845

Analog Output 8 channels

Motherboard unit

Ordering information:

MB-8U2-Y97680

MB-HO-OAV081-105290KFD2-CD-Ex1.32 (AO)

Alarm screw terminal

LEDs for power and power failure

Power supply screw terminals

Note

Fuse

----

Mod

ule

8

Mod

ule

7

Mod

ule

6

Mod

ule

5

X20

+ -

10 11 12 7 8 9

150

1. . . . .6

PW2

FF2Alarm

21 3

FF1

PW1X0.8

7 8 9 10 11 12 10 11 12

7 8 9

X0.61. . . . .61. . . . .6

F2 (T2A) + -

4 5 6

X0.7

F1 (T2A)

1. . . . .6X0.5

CR

US

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

20

xxxxxx / 36-xxxx

1 : 2

36-7250

19.06.00Date

Dept.:

Up date:

MB-8U2 Scale:

vB/KT

TZ

02.04.03

PA-VP

S

Replaces:Nr.in ch.

vB vBOff.

of 2

Norm

Sheet

contr.techn.contr.Sb/vB

1

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

7 8 9 10 11 12

7 8 9 10 11 12

X0.11. . . . .6

Adapter board

7 8 9 10 11 12

1. . . . .6

1325

X0.4 X0.31. . . . .6

X0.2

141

AP-H

O-1

0529

1

Label carrier 1

4- 4

HAZ-RTP-OAV081-105289

393

metal mounting plate

X20: 4,6

X20: 3,5

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

(0V)

copy

right

acc

ordi

ng to

DIN

34

Ground

(+ 24VDC)

52 ... 54

P1: resistor 0 Ohm

Motherboard unit

8 channelsAnalog Output

V2LB/SCPF1PF2

V157585960

56

55 P1

49 ... 51

1

8

7

23

1

8

56

4

32

7

6

5

2

654

3

6

1

56

4

5

43

46

4847

2322

24

4445

41

2019

21

42

40

1718

16

ModuleField

4 4

3 3

4

12

654

4

6

23

1

54

2

1

32

56

4

23

6

1

5

2

3837

151413

12

34

3635

1110

313233

87

9

2930

28

56

FSY-

1

5

321

6

1

X0.4

2

272625

3

Y11

RTN-x

IOUT-x

X1

xxxxxx / 36-xxxx

36-7250Up date:

Dept.:

Date

19.06.00

Shell

Scale:

02.04.03

PA-VPSb

S

P+F

Replaces:

in ch.

Nr.

SB

TZ Off.SB

Loop

1620 IOUT-7

RTN

1614

610

IOUT-6RTN

IOUT-5RTN

of 2

contr.

Sheet

Normcontr.

Sb/vB

techn.

DCS

2

Module and cable typesKFD2-CD-Ex1.32FSY-K450-98845

RTN5

46

1519

IOUT-4RTN

IOUT-3RTN

1513

9

IOUT-2RTN

IOUT-1

AO Module type:FSY- Cable type:

KF-Module terminal no.:

3

X1

5IOUT-0

Ch.

RTN

12

1011

I

V1/PR

?+1-2

10-11+

V1/PR

+1-2

10-11+

4- 5

5. TC/TK-IDX161 Application (16 channels DI 24 VDC) Page HAZ-RTP-IDX161-105281 ........................................................................... 5- 1 Documentation ............................................................................................. 5- 2

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\5-TC-IDX161-B.doc

5- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

21.02.03

Dept.:

Date TD

KT

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6193A

1 : 5

TC/TK-IDX161 DI 24 V DC (10 ... 30 V)16 ch.

LOOP-DIAGRAM (2-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

TC-IX16116 point digital input module

System cable *1)

KFD2-... (Module see table)

Module

KFD2-SR2-Ex2.2SDI

Signal

HAZ-RTP-IDX161-105281

Motherboard System cable *1) HART communication *2)

---HAZ-37xMx

Option

Sb.

Power supply 24 VDC (redundant) *Alarm (dry conntact NC)

TC-IDX161

IN-0System cable

X1

CH 1 GND-0

13 1

4 15

10

11

12

1 2

3

1 2

3

1 2

3

13 1

4 15

10

11

12

7 8

9

Module 3

Module 5

Module 6

Module 4

Module 8

Module 7

4 5

6

4 5

6

4 5

6

13 1

4 15

7 8

9

10 1

1 12

7

8

9

10

11

12

7 8

9

13 1

4 15

10

11

12

7 8

9

7 8

9

10 1

1 12

13

14

15

13 1

4 15

Module 2

Module 1

10 1

1 12

10

11

12

7 8

9

7 8

9

13 1

4 15

13

14

15

1. .

. . .6

HA

Z-R

TP-X

XXXX

X1

371

24

35

6

F1 (T

2A)

FF1

X0.7

1. .

. . .6

X0.8

PW1

X0.6

1. .

. . .6

FF2

PW2

F2 (T

2A)

+

-Al

arm

+

-

US C

X0.4

1. .

. . .6

X0.5

1. .

. . .6

X0.3

1. .

. . .6

19

X20

MB-

HO

-XXX

XX

20

AP-XX-XXXXX

X0.1

1. .

. . .6

X0.2

1. .

. . .6

1

Sensors acc.DIN EN 60 947-5-6 (NAMUR)or switch contacts

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

IN-1GND-0CH 2

Power Rail(Power supply + LB/SC)

LB= Lead Breakcage on field loop!SC = Short circuit on field loop!

* LB/SC

*1) ... *2) see table

-3

+12

-3

+1

-6

+41110

12

89

7

5-6

+4

165

150

(dry cont. NC)Alarm

2.2

1.2

2.1

1.1

1756 Rack IO Modules

APPLICATION FOR

Honeywell1756 Rack IO Modules

MB-HO-IDX161-103652

165

7 8 9

1. . . . .6

7 8 9 10 11 12 10 11 12

HAZ-RTP-IDX161-105281

Description

HAZ-RTP-IDX161-105281

Motherboard without modules, adapter board,

Motherboard without modulesKF-Module type (function)

Adapter board Label carrier 1 Cabel tree connection KF-Module-Motherboard

FSY cable tree and Label carrier

37 pin female system connector DSUB

6 pin male terminals for cable tree FSY....

HAZ-RTP-IDX161-105281

PW1, PW2, FF1, FF2

1 piece:

Basic components:

composed by:

1 piece:1 piece:8 pieces:

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

1 piece:8 pieces:

Name

X0.1 .... 8X20.3 .... 6

F1, F2X20.1, X20.2

----X1

KFD0-LC1-8M-99143FSY-L456-98837

AP-HO-103653

Digital Input 16 channels

Motherboard unit

Ordering information:

MB-8U2-Y97680

Alarm screw terminal

LEDs for power and power failure

Power supply screw terminals

MB-HO-IDX161-103652KFD2-SR2-Ex2.2S (DI)

----

Note

Fuse

Mod

ule

8

Mod

ule

7

Mod

ule

6

Mod

ule

5

X20

+ -

10 11 12 7 8 9

150

1. . . . .6

PW2

FF2Alarm

21 3

FF1

PW1X0.8

7 8 9 10 11 12 10 11 12

7 8 9

X0.61. . . . .61. . . . .6

F2 (T2A) + -

4 5 6

X0.7

F1 (T2A)

1. . . . .6X0.5

CR

US

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

20

xxxxxx / 36-xxxxReplaces:

1 : 2

36-7224

06.03.00

Date

Dept.:

Up date:

MB-8U2 Scale:

vB/DN

TZ

13.10.00

PA-VP

S

Nr.in ch.

Sb SbOff.

of 2

Norm

Sheet

contr.techn.contr.Sb

1

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

7 8 9 10 11 12

7 8 9 10 11 12

X0.11. . . . .6

Adapter board

X1

7 8 9 10 11 12

1. . . . .6X0.4 X0.3

1. . . . .6X0.2

AP-H

O-1

0365

3

Label carrier 1

5- 2

IN-0X1

IN-1

GND-0

DCS

LB/SC

Groundmetal mounting plate

9

78

FSY- Cable type:DI Module type:

KF-Module terminal no.:

KFD2-SR2-Ex2.2SFSY-L456-98837

Module and cable types

49 ... 51

56

55

585960

57V1

PF1PF2

V2

52 ... 54

(+ 24VDC)

(0V) X20: 4,6

X20: 3,5

xxxxxx / 36-xxxxReplaces:

Ch.

IN-14

IN-15GND-3

IN-12

IN-13GND-3

IN-10

IN-11GND-2

IN-8

IN-9GND-2

IN-6

IN-7GND-1

IN-4

IN-5GND-1

IN-2

IN-3GND-0

GND-0

37 n.c.36 n.c.

33 n.c.35 n.c.

IN-1

IN-0

vB/BK13.08.03Up date:

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

Digital InputMotherboard unit

16 channelsHAZ-RTP-IDX161-105281

Loop for channel 1 and 2

2, 41

3

7

56, 8

10, 129

11

15

1314, 16

18, 2017

19

23

2122, 24

26, 2825

27

31

2930, 32

8

7

6

5

4

3

2

1

X1

39

43

4748

46

4544

4142

40

3738

3536

34

31

3332

2930

28

27

2526

2322

8

24

23

56

1

4

2019

7

21

23

56

1

4

1716

6

18

23

56

1

4

1413

5

15

23

56

1

4

1110

4

12

23

56

1

4

87

3

9

23

56

1

4

54

2

6

23

56

1

4

FSY-

2

1

3

23

56

1

Y11

X0.ModuleField

4

in ch.Off. contr. contr.

of

Sheet

Scale:

Dept.:

Date

SB Sb/vBSb

36-7224

06.03.00

Nr.PEPPERL+FUCHS

Normtechn.TZS

PA-VP

2

2

+4 101112-6

5

LB/SCV1/PR

2.2

1.2

+1

-32

7

92.1

1.1 8

Shell

+4 101112-6

5

LB/SCV1/PR

2.2

1.2

+1

-32

7

92.1

1.1 8

(on Board)0V+ 24VDC

Groundmetal mounting plate

5- 3

6. TC/TK-IDD321 Application (32 channels DI 24 VDC) Page HAZ-RTP-IDD321-105270 ........................................................................... 6- 1 Documentation ............................................................................................. 6- 2

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\6-TC-IDD321-B.doc

6- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

21.02.03

Dept.:

Date TD

KT

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6192A

1 : 5

TC/TK-IDD321 DI 24 V DC (10 ... 30 V)32 ch.

LOOP-DIAGRAM (4-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

TC-IDD32132 point digital input module

KFD2-... (Module see table)

Module

KFD2-SRA-Ex4DI

Signal

HAZ-RTP-IDD321-105270

Motherboard System cable *1) HART communication *2)

---HAZ-37xMx

Option

Sb.

Power supply 24 VDC (redundant) *Alarm (dry conntact NC)

TC-IDD321

IN-0

System cableX1CH 1

IN-1

13 1

4 15

10

11

12

1 2

3

1 2

3

1 2

3

13 1

4 15

10

11

12

7 8

9

Module 3

Module 5

Module 6

Module 4

Module 8

Module 7

4 5

6

4 5

6

4 5

6

13 1

4 15

7 8

9

10 1

1 12

7

8

9

10

11

12

7 8

9

13 1

4 15

10

11

12

7 8

9

7 8

9

10 1

1 12

13

14

15

13 1

4 15

Module 2

Module 1

10 1

1 12

10

11

12

7 8

9

7 8

9

13 1

4 15

13

14

15

1. .

. . .6

HA

Z-R

TP-X

XXXX

X1

371

24

35

6

F1 (T

2A)

FF1

X0.7

1. .

. . .6

X0.8

PW1

X0.6

1. .

. . .6

FF2

PW2

F2 (T

2A)

+

-Al

arm

+

-

US C

X0.4

1. .

. . .6

X0.5

1. .

. . .6

X0.3

1. .

. . .6

19

X20

MB-

HO

-XXX

XX

20

AP-XX-XXXXX

X0.1

1. .

. . .6

X0.2

1. .

. . .6

1

Sensors acc.DIN EN 60 947-5-6 (NAMUR)or switch contacts

4-6 4

+5

-3

-4

+2

-1

3

2

3

2

11

11

9

8

7

-6

+5

-3

-4

+2

-1

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

IN-2

10

12

CH 2CH 3

IN-3CH 4

GND-0

Power Rail(Power supply + LB/SC)

LB= Lead Breakcage on field loop!SC = Short circuit on field loop!

* LB/SC

*1) ... *2) see table

165

150

(dry cont. NC)Alarm

LB/S

C

APPLICATION FOR

Honeywell1756 Rack IO Modules

1756 Rack IO Modules

System cable *1)

6- 1

MB-HO-IDD321-103654KFD2-SRA-Ex4 (DI)

Ordering information:

MB-8U2-Y97680

Alarm screw terminal

LEDs for power and power failure

Power supply screw terminals

24VDC/0,56A/13,5W

Digital Input 32 channels

Motherboard unit

FSY-K123L456-99154KFD0-LC1-8M-99143

HAZ-RTP-IDD321-105270

37 pin female system connector DSUB

6 pin male terminals for cable tree FSY....

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

PEPPERL+FUCHS

8 pieces:

1 piece:1 piece:

AP-HO-103655

composed by:1 piece:8 pieces:Basic components:

1 piece:

PW1, PW2, FF1, FF2

X20.1, X20.2

Power consumption

F1, F2

X0.1 .... 8X20.3 .... 6

----X1Name

Fuse

----

Note

FSY cable tree and Label carrier

MB-8U2

06.03.00

Up date:

Cabel tree connection KF-Module-Motherboard

Adapter board Label carrier 1

Dept.:

Date

Scale: 1 : 2 of 2

techn.contr.Sb/vB

36-7226Axxxxxx / 36-xxxx

Replaces:Nr.PA-VP

07.09.06vB

S TZ

SBOff.

in ch.

SB

Sheet 1

Normcontr.

Motherboard without modules, adapter board,

HAZ-RTP-IDD321-105270

Description

Motherboard without modulesKF-Module type (function)

3719

201

20

4 5 6 1 2 3

4 5 6 1 2 3

F1 (T2A)

X0.7

F2 (T2A)

1. . . . .6

10 11 12 7 8 9 7 8 9

10 11 12

Mod

ule

7

Mod

ule

8

X20

1. . . . .6

PW2

3 + -Alarm

1 2

FF2 + -

4 65

PW1

FF1

X0.8

150

Mod

ule

1

Mod

ule

2

Mod

ule

4

Mod

ule

3

Mod

ule

5

Mod

ule

6

10 11 12 7 8 9

Adapter board

MB-HO-IDD321-103654

165

HAZ-RTP-IDD321-105270

10 11 12 7 8 9

1. . . . .61. . . . .6 1. . . . .6

LB/SCC

US

R

X0.6 X0.5 X0.4

7 8 9 10 11 12 10 11 12

7 8 9

1. . . . .61. . . . .6 1. . . . .6X0.2

X1

X0.3

AP

-HO

-103

655

X0.1

10 11 12 7 8 9

10 11 12 7 8 9

4 5 6 1 2 3 Label carrier 1

6- 2

GND-135, 363 39

IN-28

IN-31GND-1IN-30

IN-29GND-1

IN-24

IN-27GND-1IN-26

IN-25GND-1

IN-20

IN-23GND-1IN-22

IN-21GND-1

IN-19

52 ... 540V

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

PEPPERL+FUCHS

copy

right

acc

ordi

ng to

DIN

34

metal mounting plateGround

RB-V2LB/SC

PF2PF1

RB-V1

HAZ-RTP-IDD321-10527032 channels

Motherboard unit Digital Input

Electonic circuit(Adapter board)

57

5960

58

56

55

LB/SCX20.1, 2

Shell

RelayK1

6

7

8

5

1

+ 24VDC

8

23

1

7

654

32

2

6

654

3

5

1

654

43

49 ... 51

4748

46

242322

4544

32

37 n.c.

34

3335, 36

31

30

29

35, 36

35, 36

41

212019

42

40

181716

25

28

27

26

35, 36

35, 36

24

23

22

35, 36

Scale: of 2

(on Board)0V

Nr.

SbOff.

in ch.

xxxxxx / 36-xxxxReplaces:

PA-VPDept.:

Up date:

06.03.00

Date TZ

SB

S

LB/SCV1/PR

+ 24VDC

36-7226A

Sb/vBcontr.techn.

Sheet 2

Normcontr.

Groundmetal mounting plate

Loop for channel 1 ... 4

92-3

+5

-6

-4

11

124

103

+2

-1

18

7

GND-0

IN-3

IN-2

IN-1

GND-0

IN-0X1 DCS

IN-16

IN-18

IN-17GND-1

IN-12

IN-15GND-0IN-14

IN-13GND-0

IN-11GND-0IN-10

GND-0

GND-0

GND-0

GND-0

GND-0

Ch.

IN-4544

4

2

33

4

12

6

45

6

23

1

54

1

32

56

4

232

6

1

5

3738

151413

12

3536

34

1110

16

21

20

1935, 36

17, 18

17, 1813

15

14

31

3332

89

7

2930

6

28

5

17, 18

17, 1810

12

11

9

IN-9

IN-8

17, 18

17, 18

7

6

8

IN-6

IN-7

IN-5

1

X0.

V1/PR

Module

+2

-6

-4+5

-3

Field-1

58

LB/SC

4

112

3

2

1110

9

3

12

6

FSY-

17 4

2

27

2526

3

Y11

17, 18

17, 18

2

3

4 IN-3

IN-2

IN-1

1

X1

IN-0 FSY-K123L456-99154KFD2-SRA-Ex4

Module and cable types

FSY- Cable type:KF-Module terminal no.:

12

1011

87

9

DI Module type:

07.09.06vB

6- 3

7. TC/TK-ODX121 Application (16 channels DO 24 VDC) Page HAZ-RTP-ODX121-118258 (Not in commercial agreement) ....................... 7- 1 Documentation ............................................................................................. 7- 2

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\7-TC-ODX161-B.doc

7- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

21.02.03

Dept.:

Date TD

KT

11.12.03Sb/BK

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6195A

1 : 5

TC/TK-ODX161 DO 24 V DC16 ch.

LOOP-DIAGRAM (2-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

TC-OX12116 point digital output mod.

KFD2-... (Module see table)

Module

KFD2-SL2-Ex2.BDO

Signal

HAZ-RTP-ODX161-118258

Motherboard System cable *1) HART communication *2)

---HAZ-37xMx

Option

Sb.

Power supply 24 VDC (redundant)Alarm (dry conntact NC)

TC-ODX121

IN-0System cable

X1

CH 1 GND-0

13 1

4 15

10

11

12

1 2

3

1 2

3

1 2

3

13 1

4 15

10

11

12

7 8

9

Module 3

Module 5

Module 6

Module 4

Module 8

Module 7

4 5

6

4 5

6

4 5

6

13 1

4 15

7 8

9

10 1

1 12

7

8

9

10

11

12

7 8

9

13 1

4 15

10

11

12

7 8

9

7 8

9

10 1

1 12

13

14

15

13 1

4 15

Module 2

Module 1

10 1

1 12

10

11

12

7 8

9

7 8

9

13 1

4 15

13

14

15

1. .

. . .6

HA

Z-R

TP-X

XXXX

X1

371

24

35

6

F1 (T

2A)

FF1

X0.7

1. .

. . .6

X0.8

PW1

X0.6

1. .

. . .6

FF2

PW2

F2 (T

2A)

+

-Al

arm

+

-

US C

X0.4

1. .

. . .6

X0.5

1. .

. . .6

X0.3

1. .

. . .6

19

X20

MB-

HO

-XXX

XX

20

AP-XX-XXXXX

X0.1

1. .

. . .6

X0.2

1. .

. . .6

1

IN-1GND-0CH 2

*1) ... *2) see table

Power Rail(Power supply)

3

6

+4-5

+1-2

+1-2

+4-5

Valves

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

& (dry cont. NC)Alarm

165

150

8

9

7

APPLICATION FOR

Honeywell1756 Rack IO Modules

1756 Rack IO Modules

System cable *1)

7- 1

165

7 8 9

1. . . . .6

7 8 9 10 11 12 10 11 12

HAZ-RTP-ODX161-118258

6 pin male terminals for cable tree FSY....

37 pin female system connector DSUB

FSY cable tree and Label carrier

Cabel tree connection KF-Module-MotherboardLabel carrier 1 Adapter board

KF-Module type (function)Motherboard without modules

Motherboard without modules, adapter board,

Description

HAZ-RTP-ODX161-118258

MB-HO-ODX161-118259

HAZ-RTP-ODX161-118258

PW1, PW2, FF1, FF2

8 pieces:1 piece:1 piece:

1 piece:composed by:

Basic components:

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

8 pieces:1 piece:

X20.1, X20.2F1, F2

X20.3 .... 6X0.1 .... 8

Name

----X1

KFD0-LC1-8M-99143AP-HO-118260

FSY-L456-98837

Motherboard unit

16 channelsDigital Output

Power supply screw terminals

LEDs for power and power failure

Alarm screw terminal

MB-8U2-Y97680

Ordering information:

KFD2-SL2-Ex2.B (DO)MB-HO-ODX161-118259

Fuse

Note

----

Mod

ule

8

Mod

ule

7

Mod

ule

6

Mod

ule

5

X20

+ -

10 11 12 7 8 9

150

1. . . . .6

PW2

FF2Alarm

21 3

FF1

PW1X0.8

7 8 9 10 11 12 10 11 12

7 8 9

X0.61. . . . .61. . . . .6

F2 (T2A) + -

4 5 6

X0.7

F1 (T2A)

1. . . . .6X0.5

CR

US

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

20

xxxxxx / 36-xxxxReplaces:

36-7461Up date:

Dept.:

Date

04.03.02

MB-8U2 Scale:

03.05.04

TZ

PA-VPSb/Bro

S in ch.

Nr.

SBOff.SB

of1 : 2 2

contr.

Sheet

Norm

Sb/vBcontr.techn.

1

3719

201

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

7 8 9 10 11 12

7 8 9 10 11 12

X0.11. . . . .6

Adapter board

7 8 9 10 11 12

1. . . . .6

X1

X0.4 X0.31. . . . .6

X0.2

AP-H

O-1

1826

0

Label carrier 1

7- 2

X1OUT-0

DCS

DC-0 (+)

OUT-1

DC-0 (+)

DC-0 (+)

DC-1 (+)

LB/SC

52 ... 54

49 ... 51

Groundmetal mounting plate

Shell (X1)

Loop for channel 1 and 2

34 GND-1

35 n.c.33 n.c.

55

56

60595857

V1

PF2PF1

V2

(+ 24VDC)

(0V)

X20: 3,5

X20: 4,6

GND-1

n.c.GND-016

36

32

9

78

KF-Module terminal no.:

FSY- Cable type:DO Module type: KFD2-SL2-Ex2.B

FSY-L456-98837

Module and cable types

2

contr.techn.

Sb/vB

Sheet

contr.Norm

2of

SbOff.

Sb

TZ in ch.

Nr.Replaces:

S

Sb/BroPA-VP

03.05.04

Scale:MB-8U2

04.03.02

Date

Dept.:

Up date:

36-7461xxxxxx / 36-xxxx

Motherboard unitDigital Output16 channels - one pick-offHAZ-RTP-ODX161-118258

2625

27

28

3029

3233

31

34

3635

3837

40

4241

4445

46

4847

43

39

OUT-14

OUT-15+DC-1

OUT-12

OUT-13+DC-1

OUT-10

OUT-11+DC-1

OUT-8

OUT-9+DC-1

OUT-6

OUT-7+DC-0

OUT-4

OUT-5+DC-0

OUT-2

OUT-3+DC-0

+DC-0

Ch.

OUT-1

OUT-0

1

copy

right

acc

ordi

ng to

DIN

34un

auth

oriz

ed d

istri

butio

n an

d re

prod

uctio

n pr

ohib

ited

2, 41

3

7

56, 8

10, 129

11

15

1314

18, 2017

19

23

2122, 24

26, 2825

27

31

2930

8

7

6

5

4

3

2

X1

2322

8

24

23

56

1

4

2019

7

21

23

56

1

4

1716

6

18

23

56

1

4

1413

5

15

23

56

1

4

1110

4

12

23

56

1

4

87

3

9

23

56

1

4

54

2

6

23

56

1

4

FSY-

2

1

3

23

56

1

Y11

X0.ModuleField

4

PEPPERL+FUCHS

0V(on Board)

+ 24VDC

Groundmetal mounting plate

-

-

8

V1/PR

+ -56

+4

9

+ -23

+1 7

8

V1/PR

-56

+4

9

-23

+1 7

7- 3

8. TC/TK-ODD321 Application (32 channels DO 24 VDC) Page HAZ-RTP-ODD321-105271 ......................................................................... 8- 1 Documentation ............................................................................................. 8- 2

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\8-TC-ODD321-B.doc

8- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

21.02.03

Dept.:

Date TD

KT

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

+

-

X0.2

10 1

1 12

Module 15

1. .

. . .6

7 8

9

X0.1

1

7 8

9

Module 6

4 5

6

1 2

3

4 5

6

7 8

9

10 1

1 12

1. .

. . .6

1 2

3

4 5

6

1 2

3

4 5

6

4 5

6

1 2

3

1 2

3

1 2

3

4 5

6

X0.1

6

10 1

1 12

7

8

9

1. .

. . .6

Module 1

Y1

7 8

9

10 1

1 12

10

11

12

Module 2

Module 3

7 8

9

10 1

1 12

Module 5

Module 4

10 1

1 12

7

8

9

1. .

. . .6

X0.1

51.

. . .

.6X0

.14

1. .

. . .6

X0.1

21.

. . .

.6X0

.13

1 2

3

4 5

6

1 2

3

4 5

6

7 8

9

10 1

1 12

10

11

12

10 1

1 12

7

8

9

Module 7

Module 8

7 8

9

10 1

1 12

Module 9

Module 10

7 8

9

10 1

1 12

1. .

. . .6

X0.1

01.

. . .

.6X0

.9X0

.81.

. . .

.6X0

.71.

. . .

.6

7 8

9

7 8

9

10 1

1 12

Module 12

Module 11

10 1

1 12

7

8

9

Module 14

Module 13

10 1

1 12

7

8

9

X0.4

1. .

. . .6

1. .

. . .6

X0.6

1. .

. . .6

X0.5

X0.3

1. .

. . .6

Alar

m21

X20

Module 16

PW2

X0.1

1. .

. . .6 FF

1

PW1

FF2

+

-5

63

4

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

7 8

9

10 1

1 12

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

13

14

15

13 1

4 15

36-6194A

AP-XX-XXXXX

HA

Z-R

TP-X

XXXX

MB-

HO

-XXX

XX

CUS

3719

X1201

TC-IAH161

OUT-0

System cableX1

DC-1 (+)

RTN OUT-1

DC-0 (+)

RTN OUT-0

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

1 : 5

TC/TK-ODD321 DO 24 V DC32 ch.

Alarm (dry conntact NC)Power supply 24 VDC (redundant)

LOOP-DIAGRAM (2-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

TC-ODD32132 pointdigital output mod.

CH 1

OUT-1

KFD2-... (Module see table)

Module

KFD2-SL2-Ex2.BDO

Signal

HAZ-RTP-ODD321-105271

Motherboard System cable *1) HART communication *2)

---HAZ-37xMx

Option

Power Rail(Power supply)

Sb.

*1) ... *2) see table

Valves

CH 2

150

325

(dry cont. NC)Alarm

8

9

7

1756 Rack IO Modules

APPLICATION FOR

Honeywell1756 Rack IO Modules

System cable *1)

3

6

+4-5

+1-2

+1-2

+4-5

8- 1

6 pin male terminals for cable tree FSY....

FSY cable tree and Label carrier

Cabel tree connection KF-Module-MotherboardLabel carrier 1 Adapter board

KF-Module type (function)Motherboard without modules

Motherboard without modules, adapter board,

Description

37 pin female system connector DSUB

HAZ-RTP-ODD321-105271

13 14 15

AP

-HO

-103

657

10 11 12 7 8 9

1 2 3 4 5 6

32 channels - one pick-offHAZ-RTP-ODD321-105271

Power consumption

16 pieces:1 piece:1 piece:

composed by:

Basic components:

1 piece:

PW1, PW2, FF1, FF2

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

16 pieces:1 piece:

X20.1, X20.2F1, F2

X20.3 .... 6X0.1 .... 16

Name

----X1

KFD0-LC1-16M-99144AP-HO-103657

FSY-L456-98837

Motherboard unitDigital Output

24VDC/2A/48W

Power supply screw terminals

LEDs for power and power failure

Alarm screw terminal

MB-16U5L-103681

Ordering information:

MB-HO-ODD321-103656KFD2-SL2-Ex2.B (DO)

Fuse

Note

----

13 14 15 13 14 15

1. . . . .6

1 2 3 4 5 6

10 11 12 7 8 9

Mod

ule

15

X0.15

7 8 9 10 11 12

1 2 3 4 5 6

150

X0.161. . . . .6

Y1

Mod

ule

16

13 14 15

19

HAZ-RTP-ODD321-105271

MB-HO-ODD321-103656

1. . . . .6

Mod

ule

12

X0.12

7 8 9 10 11 12

Adapter board

C

R

US

13 14 15 13 14 15

1. . . . .6

10 11 12 7 8 9

10 11 12

1. . . . .6X0.14

Mod

ule

14

X0.13

7 8 9

Mod

ule

13

X1

371

20

325

13 14 15 13 14 15

1. . . . .6

7 8 9 7 8 9 10 11 12 10 11 12

X0.101. . . . .6

X0.11

Mod

ule

111. . . . .6

X0.9

Mod

ule

10

Mod

ule

9

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

1 2 3 4 5 6

xxxxxx / 36-xxxx

36-7227AUp date:

Dept.:

Date

07.03.00

MB-16U5L Scale:

vB07.09.06

PA-VP

S

Replaces:Nr.in ch.TZ

SBOff.SB

of1 : 2 3

Normcontr.

Sheet

Sb/vB

techn.contr.

1

13 14 15 13 14 15

1. . . . .6

7 8 9

Mod

ule

2

10 11 12

X0.2

10 11 12 7 8 9

13 14 15 13 14 15

1. . . . .6

10 11 12 7 8 9

X0.5

10 11 12 7 8 9

13 14 15

1. . . . .6

Mod

ule

7

10 11 12 7 8 9

10 11 12

X0.7

13 14 15

1. . . . .6X0.8

7 8 9

Mod

ule

8

1. . . . .6X0.6

Mod

ule

6

13 14 15

7 8 9 10 11 12

1. . . . .6X0.4

Mod

ule

5

Mod

ule

4

1. . . . .6X0.3

Mod

ule

3

Label carrier 1

PW2

FF2

13 14 15 10 11 12 7 8 9

1. . . . .6X0.1

FF1

PW1

Mod

ule

1

F1 (T2A)

F2 (T2A)

1Alarm

6 + - + -

2 3 54

X20

8- 2

RTN OUT-017

9

78

KF-Module terminal no.:

FSY- Cable type:DO Module type: KFD2-SL2-Ex2.B

FSY-L456-98837

Module and cable types

2

contr.techn.

Sb/vB

Sheet

contr.Norm

3of

SBOff.

SB

TZ in ch.

Nr.Replaces:

S

vBPA-VP

07.09.06

Scale:MB-16U5L

07.03.00

Date

Dept.:

Up date:

36-7227Axxxxxx / 36-xxxx

Motherboard unitDigital Output32 channels - one pick-offHAZ-RTP-ODD321-105271

2625

27

28

3029

3233

31

34

3635

3837

40

4241

4445

46

4847

43

39

OUT-14

OUT-15

OUT-12

OUT-13

OUT-10

OUT-11

OUT-8

OUT-9

OUT-6

OUT-7

OUT-4

OUT-5

OUT-2

OUT-3

Ch.

OUT-1

OUT-0

1

copy

right

acc

ordi

ng to

DIN

34un

auth

oriz

ed d

istri

butio

n an

d re

prod

uctio

n pr

ohib

ited

1

2

4

3

5

6

8

7

9

10

12

11

13

14

16

15

8

7

6

5

4

3

2

X1

2322

8

24

23

56

1

4

2019

7

21

23

56

1

4

1716

6

18

23

56

1

4

1413

5

15

23

56

1

4

1110

4

12

23

56

1

4

87

3

9

23

56

1

4

54

2

6

23

56

1

4

FSY-

2

1

3

23

56

1

Y11

X0.ModuleField

4

PEPPERL+FUCHS

-

-

8

V1/PR

+ -56

+4

9

+ -23

+1 7

Y1: 26

8- 3

35 RTN OUT-1

LB/SC

Groundmetal mounting plate

49 ... 51

56

55

585960

57V1

PF1PF2

V2

52 ... 54

(+ 24VDC)

(0V) X20: 4,6

X20: 3,5

DC-1 (+)

DC-0 (+)

RTN OUT-1

DCSX1OUT-0

OUT-1

RTN OUT-0

3

Sb/vB

techn.contr.

Normcontr.

Sheet

3of

Off.SBSB

TZ

Replaces:Nr.in ch.S

PA-VP

07.09.06vB

Scale:MB-16U5L

Up date:

Dept.:

Date

07.03.00

xxxxxx / 36-xxxx

36-7227ADigital OutputMotherboard unit

HAZ-RTP-ODD321-10527132 channels - one pick-off

DC-1(+)36

Loop for channel 1 and 2

Shell

OUT-3134

OUT-30

DC-0(+)

OUT-28

OUT-29

OUT-26

OUT-27

OUT-24

OUT-25

OUT-22

OUT-23

OUT-21

OUT-20

OUT-19

OUT-18

OUT-16

Ch.

OUT-17

X1

9

10

12

11

13

14

15

16

25

27

8685

28

87

26

2930

88

9089

3231

33

939291

363534

96

9495

3837

39

9798

404142

100

102

4445

43

101

105104

4746

48

108

106107

103

99

copy

right

acc

ordi

ng to

DIN

34un

auth

oriz

ed d

istri

butio

n an

d re

prod

uctio

n pr

ohib

ited

21

22

25

26

30

29

33

18

19

20

24

28

27

31

32

23

16

23

56

1

4

15

23

56

1

4

14

23

56

1

4

13

23

56

1

4

12

23

56

1

4

11

23

56

1

4

10

23

56

1

4

FSY-

2

9

3

56

1

Y1X0.ModuleField

4

PEPPERL+FUCHS

0V(on Board)

+ 24VDC

8

V1/PR

-56

+4

9

-23

+1 7

Y1: 23

8- 4

9. TC/TK-HAI081 Application HART Integration to 1756 Rack IO Modules (8 channels AI current 4 … 20 mA) Page HAZ-RTP-HAI081-127742 ........................................................................... 9- 1 Documentation ............................................................................................. 9- 2

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\9-TC-HAI081-B.doc

9- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

10.12.03

Dept.:

Date TD

BK

26.03.04Sb/Bro

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6031A

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

1 : 5

TC/TK-HAI081 AI current 4 ... 20 mA8 ch.

LOOP-DIAGRAM (1-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

2-, 3-wire Transmitter(0/4 ... 20 mA)

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

HART-Multiplexer

TC-HAI0818 point high-levelanalog input mod.

KFD2-... (Module see table)

Module

KFD2-STC4-Ex1AI, current

Signal

HAZ-RTP-HAI081-127742

Motherboard System cable *1) HART communication *2)

yesHAZ-37xMx

Option

Sb.

Power supply 24 VDC (redundant)Alarm (dry conntact NC)

4 5

6

1 2

3

4 5

6

4 5

6

1 2

3

1 2

3

7 8

9

10 1

1 12

X0.6

1. .

. . .6

10 1

1 12

7

8

9

1. .

. . .6

7 8

9

10 1

1 12

1. .

. . .6

F1 (T

2A)

+

- 4F2 (T

2A)

PW2

PW1

FF1X0

.8

1FF2

Alar

m3

2

X0.7

+

-5

6

X20

7 8

9

7 8

9

X0

.31.

. . .

.6

10 1

1 12

7

8

9

HA

Z-R

TP-X

XXXX

10 1

1 12

7

8

9

1. .

. . .6

10 1

1 12

1. .

. . .6

MB-

HO

-XXX

XX

X0.5

US C

X0.4

7 8

9

10 1

1 12

1. .

. . .6

10 1

1 12

1. .

. . .6

X0.2

AP-XX-XXXXX

X0.1

Module 8

Module 7

Module 5

Module 6

Module 4

Module 2

Module 3

Module 1

from X3additional motherboard(ch. 9 ... 16)

Cable type K-HM26

Multiplexer

TC-HAI081

i RTN-0

Cable type K-HM26

System cable

X3

X1

RTN

HART

RTNRTN

RTN

-

3

CH 1+ i IN-0

CH 1

3

+1-2

HART

R

7-

9+8+

+6-5

Power Rail(Power supply)

*1) ... *2) see table

165

150

+1-2

(dry cont. NC)Alarm

X2

8 channels

CH 8

from second motherboard (X3)

Cable type K-HM26

CH 1

25 26

X21

251 2

262

X3

X1

Can also be used for internal HART communication applications

3719201

APPLICATION FOR

Honeywell1756 Rack IO Modules

1756 Rack IO Modules

System cable *1)

Cable type K-HM26 *2)

9- 1

copy

right

acc

ordi

ng to

DIN

34

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

20

1 2 31 2 3 1 2 3 Label carrier 1 4 5 64 5 6

7 8 97 8 9

Mod

ule

7

Mod

ule

8

150

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

Mod

ule

6

Mod

ule

5

7 8 97 8 97 8 9 7 8 9 7 8 9 7 8 9

4 5 6

X0.7 1. . . . .6

10 11 12 10 11 12

1. . . . .6 X0.8

10 11 12 10 11 12

1. . . . .6 1. . . . .6 1. . . . .6 X0.6 X0.5 X0.4

10 11 12 10 11 12

1. . . . .6 1. . . . .6 1. . . . .6 X0.2 X0.3 X0.1

10 11 12 10 11 12

F1 (T2A)

PW1

FF1 HAZ-RTP-HAI081-127742 MB-HO-HAI081-127745 X1

F2 (T2A)

PW2

3 + ­Alarm

1 2

FF2 + ­

4 65 C U

S R

X2 AP

-HO

-127

746

X3

24VDC/0,84A/20W

Alarm screw terminal

26 pin HART connector male

LEDs for power and power failure

Power supply screw terminals

KFD2-STC4-Ex1 (AI) MB-HO-HAI081-127745

Ordering information:

37 pin female system connector DSUB

6 pin male terminals for cable tree FSY....

8 pieces: 1 piece:

Basic components:

PW1, PW2, FF1, FF2

X20.1, X20.2

Power consumption

F1, F2

X0.1 .... 8 X20.3 .... 6

X2, X3 X1 Name

Fuse

Note

KF-Module type (function) Motherboard without modules

Description

HAZ-RTP-HAI081-127742

X20 1 25 125

Adapter board

165

26 2 26 2

composed by: MB-8U2-Y97680 1 piece: Motherboard without modules, adapter board,

FSY cable tree and Label carrier 1 piece: AP-HO-127746 Adapter board

KFD0-LC1-8M-99143 1 piece: Label carrier 1 FSY-L456-98837 8 pieces: Cabel tree connection KF-Module-Motherboard

28.01.04 BK Sb Sb

Date S TZ Off. in ch. techn.

contr. Norm contr.

PEPPERL+FUCHS Mannheim-Schönau

Motherboard unit Analog Input + HART 8 channelsHAZ-RTP-HAI081-127742

Dept.: PA-VP 36-7590D Nr. Up date: 16.04.07

vB/Dö xxxxxx / 36-xxxx

Replaces:

of

Sheet

2

1

MB-8U2 1 : 2Scale:

3 39

Hi 7

Hi 6

Hi 5

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

24 ... 2624 ... 26X20: 4,6(0V) 52 ... 54

33 ... 37n.c.

PEPPERL+FUCHS

copy

right

acc

ordi

ng to

DIN

34

metal mounting plateGround

V2

PF1PF2

LB/SC

V157

5960

58

56

55

1920

232122

1718

16

Shell

9

121113

10

76

8

5

6

7

8

1

(+ 24VDC) X20: 3,5

8

23

1

7

654

32

2

6

6

45

3

5

1

654

43

49 ... 51

4748

46

14, 151 ... 5

242322

4544

1326

14, 151 ... 5

Com28

41

21

1920

42

12

40

181716

11

Com

18

20

12 Com

10

9 ... 16

1 ... 8

8 channels extern

X2

8 channels on board

X31 ... 8

common for 8 channels

Channel distribution:

1 ... 5

24 ... 2614, 15

6

X2

7

17

16

-2 8+

V1/PR

-5+6

3 R 9+

Loop for channel 1

HART+1P+F

7-

1 ... 514, 1524 ... 26

X3

6

Hi 0

Com

X1 DCS

Hi 4

Hi 3

Hi 2

Hi 1

Hi 0

44 11 Com

2

3

4

3

4

12

6

45

6

23

1

54

1

32

56

4

232

6

1

5

3738

15

1314 10

12

3536

34

1110

9

2

Com4

25

Com27

31

3332

89

7

8

2930

6

28

5 7

Com

17

19

9

X0.

1

Module

V1/PR

HART-2

-5+6

3

Field+1

58+

1

R 9+

3

12

6

FSY-7- 4

2 6

27

2526

3

Y11

X3

1

X1X2 Ch.

Com3

Module and cable typesKFD2-STC4-Ex1FSY-L456-98837FSY- Cable type:

KF-Module terminal no.:87

9

AI Module type:

Gate 05

Gate 113

Gate 221

Gate 329

Gate 46

Gate 514

Gate 622

Gate 730

31, 3223, 2415, 167, 8

Com

ComCom

Com

n.c.

n.c.

n.c.

n.c.

n.c.

n.c.

n.c.

n.c.

28.01.04

Up date:

MB-8U2

Dept.:

Date

1 : 2Scale: of 2

36-7590Dxxxxxx / 36-xxxx

Sbcontr.techn.

Nr.Replaces:

16.04.07

PA-VPvB/Dö

S TZ

BKOff.

in ch.

Sb

Sheet 2

contr.Norm

Mannheim-Schönau

Motherboard unitAnalog Input + HART8 channelsHAZ-RTP-HAI081-127742

10. TC/TK-HAO081 Application HART Integration to 1756 Rack IO Modules (8 channels AO current 4 … 20 mA) Page HAZ-RTP-HAO081-132002 ....................................................................... 10- 1 Documentation ........................................................................................... 10- 2

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\10-TC-HAO081-B.doc

10- 0

PEPPERL+FUCHS Replaces:xxxxxx / 36-xxxx

Scale:

Up date:

29.03.04

Dept.:

Date TD

Bro

xx.xx.xx- : -

PA - VP

S

No.

in ch.Off.

of 1

Sb.contr.techn.

Sheet 1

contr.Norm

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

36-6032

LB/SC and Power Control Unit

RelayK1

1

56

43

2

0V+24V

0V

+24V

X20

&

1 : 5

TC/TK-HAO081 AO current 4 ... 20 mA8 ch.

LOOP-DIAGRAM (1-channel modules)

Transformer isolated barrier:

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

Control room non hazardous areaDCS I/O

Control room or hazardous area (Zone 2)Motherboard

Hazardous area (Zone 1)Field device

HART-Multiplexer

TC-HAI0818 point high-levelanalog input mod.

KFD2-... (Module see table)

Module

KFD2-SCD2-Ex1.LKAO, current

Signal

HAZ-RTP-HAO081-132002

Motherboard System cable *1) HART communication *2)

yesHAZ-25xMx

Option

Sb.

Power supply 24 VDC (redundant)Alarm (dry conntact NC)

4 5

6

1 2

3

4 5

6

4 5

6

1 2

3

1 2

3

7 8

9

10 1

1 12

X0.6

1. .

. . .6

10 1

1 12

7

8

9

1. .

. . .6

7 8

9

10 1

1 12

1. .

. . .6

F1 (T

2A)

+

- 4F2 (T

2A)

PW2

PW1

FF1X0

.8

1FF2

Alar

m3

2

X0.7

+

-5

6

X20

7 8

9

7 8

9

X0

.31.

. . .

.6

10 1

1 12

7

8

9

HA

Z-R

TP-X

XXXX

10 1

1 12

7

8

9

1. .

. . .6

10 1

1 12

1. .

. . .6

MB-

HO

-XXX

XX

X0.5

US C

X0.4

7 8

9

10 1

1 12

1. .

. . .6

10 1

1 12

1. .

. . .6

X0.2

AP-XX-XXXXX

X0.1

Module 8

Module 7

Module 5

Module 6

Module 4

Module 2

Module 3

Module 1

from X3additional motherboard(ch. 9 ... 16)

Cable type K-HM26

Multiplexer

TC-HAI081

i RTN-0

Cable type K-HM26

System cable

X3

X1

RTN

HART

RTNRTN

RTN

-CH 1

+ i IN-0

CH 1

*1) ... *2) see table

165

150

(dry cont. NC)Alarm

X2

8 channels

CH 8

from second motherboard (X3)

Cable type K-HM26

CH 1

25 26

X21

251 2

262

X3

Can also be used for internal HART communication applications

APPLICATION FOR

Honeywell1756 Rack IO Modules

1756 Rack IO Modules

System cable *1)

Cable type K-HM26 *2)

X113 25

141

?I

Converter, positioner(4 ... 20 mA)

Power Rail(Power supply)

+1-2

?I

+1-2

9R

HART 7-8+

10- 1

24VDC/0,84A/20W

Alarm screw terminal

26 pin HART connector male

LEDs for power and power failure

Power supply screw terminals

KFD2-SCD2-Ex1.LK (AO)MB-HO-HAO081-132003

MB-8U2-Y97680

Ordering information:

8 channels

Motherboard unitAnalog Output + HART

FSY-L456-98837KFD0-LC1-8M-99143

HAZ-RTP-HAO081-132002

25 pin female system connector DSUB

6 pin male terminals for cable tree FSY....

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

PEPPERL+FUCHS

8 pieces:1 piece:1 piece: AP-HO-132004

composed by:

8 pieces:1 piece:

Basic components:

1 piece:

PW1, PW2, FF1, FF2

X20.1, X20.2

Power consumption

F1, F2

X0.1 .... 8X20.3 .... 6

X2, X3X1Name

Fuse

Note

FSY cable tree and Label carrier

MB-8U2

Up date:

26.03.04

Cabel tree connection KF-Module-MotherboardLabel carrier 1 Adapter board

Dept.:

Date

1 : 2Scale: of 2

techn.contr.

Sb

xxxxxx / 36-xxxx

36-7632Replaces:Nr.PA-VP

xx.xx.xx- : -

S TZ

BroOff.

in ch.

Sb

Sheet 1

Normcontr.

Motherboard without modules, adapter board,

KF-Module type (function)Motherboard without modules

Description

HAZ-RTP-HAO081-132002

20

1 2 3 4 5 6

1 2 3 4 5 6

X0.7

F1 (T2A)

F2 (T2A)

1. . . . .6

7 8 9 10 11 12 10 11 12

7 8 9

Mod

ule

7

Mod

ule

8

X20

1. . . . .6

PW2

3 + -Alarm

1 2

FF2 + -

4 65

PW1

FF1

X0.8

150

Mod

ule

3

Mod

ule

4

Mod

ule

2

Mod

ule

1

Mod

ule

6

Mod

ule

5

7 8 9 10 11 12

1 25 125

Adapter board

165

26 2 26 2

7 8 9 10 11 12

HAZ-RTP-HAO081-132002

1. . . . .61. . . . .6 1. . . . .6

MB-HO-HAO081-132003

CUS

R

X0.6

X2

X0.5 X0.4

10 11 12 7 8 9 7 8 9

10 11 12

1. . . . .61. . . . .6 1. . . . .6X0.2X0.3

AP-H

O-1

3200

4

X3

X0.1

7 8 9 10 11 12

7 8 9 10 11 12

1 2 3 4 5 6

Label carrier 1

2513X1 1

14

10- 2

3 39

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

d

24 ... 2624 ... 26X20: 4,6(0V) 52 ... 54

PEPPERL+FUCHS

copy

right

acc

ordi

ng to

DIN

34

metal mounting plateGround

V2

PF1PF2

LB/SC

V1

HAZ-RTP-HAO081-132002

Analog Output - HART8 channels

Motherboard unit

57

5960

58

56

55

1920

232122

1718

16

Shell

9

121113

10

76

8

5

6

7

8

1

(+ 24VDC) X20: 3,5

8

23

1

7

654

32

2

6

6

45

3

5

1

654

43

49 ... 51

4748

46

14, 151 ... 5

242322

4544

13

14, 151 ... 5

41

21

1920

42

12

40

181716

11

Scale: - of 2

Replaces:

in ch.

Nr.

Off.Sb

9 ... 16

1 ... 8

xx.xx.xx

PA-VP- : -

Up date:

Dept.:

Date

26.03.04

TZ

Bro

S

8 channels extern

X2

36-7632xxxxxx/36-xxxx

contr.techn.

Sb

Sheet 2

contr.Norm

8 channels on board

X31 ... 8

common for 8 channels

Channel distribution:

1 ... 5

24 ... 2614, 15

6

X2

7

17

16

Loop for channel 1

P+F

1 ... 514, 1524 ... 26

X3

6

IOUT-0

RTN

X1 DCS

44

2

3

4

3

4

12

6

45

6

23

1

54

1

32

56

4

232

6

1

5

3738

15

1314 10

12

3536

34

1110

9

31

3332

89

7

8

2930

6

28

5 7

X0.

1

ModuleField

5

13

12

6

FSY-4

2 6

27

2526

3

Y11

X3 X1X2 Ch. Module and cable typesKFD2-SCD2-Ex1.LKFSY-L456-98837FSY- Cable type:

KF-Module terminal no.:87

9

AO Module type:HART

V1/PR

I? -2

+1

R

LB/SC

8+9+

7-

HART

V1/PR

-2+1

R

LB/SC

8+9+

7-IOUT-5

IOUT-6

IOUT-7

16

20

RTN

14

16 RTN

RTN6

10

IOUT-0

IOUT-1

IOUT-2

IOUT-3

IOUT-4

5 RTN

4

6 RTN

15

19

RTN

13

15 RTN

9

3

5 RTN

P1

10- 3

11. Accessories Page System cable HAZ-37-xMx......................................................................... 11- 1 System cable HAZ-25-xMx......................................................................... 11- 2 Samples of cabinet assembly..................................................................... 11- 3 Cables for the HART Multiplexer-System................................................... 11- 5

M:\MB-DCS\HONEYWELL\ROCKWELL-1756 Rack IO Modules\EX\Katalog\Vollversion\Aktuell\TMDOC0944B_ENG\ORG\11-Accessories-B.doc

11- 0

Honeywell 1756 Rack IO Modules

Pinout Honeywell 1756 Rack IO Modules system cable

2121white/blue

yellow/blackgreen/black

brown/black

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

green/blue

NC

yellow/bluegreen/redyellow/red

grey/greenyellow/greypink/greenyellow/pink

brown/blue

white/black

white/redbrown/red

System cablePinout

31

3637

3435

3233

26

2930

2728

232425

22

31

36----

3435

3332

26

2930

2827

232425

22

cable type LIYCY 36x0,34mm²

Color code

white/yellowyellow/brown

brown/greenwhite/green

white

grey/pink

grey/brownwhite/grey

pink/brownwhite/pink

red/blue

pink

blackviolet

redblue

yellowgreenbrown

grey

11

16

18

2019

17

13

1514

12

8

109

76

3

5

4

21

11

16

1819

20

17

131415

12

8910

67

34

5

12

SUB-D37(HAZ 37) (Male) I/O Terminal block

36-6066F1xxxxxx / 36-xxxx

Replaces:

Date

Dept.:

01.02.01

Up date:

Scale:

PA - VP

TD

vB/Dö07.02.08

S in ch.

No.

KTOff.

of 1

Normcontr.

Sheet

techn.contr.Sb.

1

M = metersLength in meters

HAZ - 37 - x M x - XXXXXType code:

PartNo. (see table)0 or 5 (0 or half meter)

PartNo. Honeywell 1756 RackIO Modules RTPHAZ-RTP cables

198869 HAZ-37-xMx-198869133679 HAZ-37-0M5-133679131739 HAZ-37-1M0-131739131740 HAZ-37-1M5-131740131741 HAZ-37-2M0-131741131742 HAZ-37-2M5-131742131743 HAZ-37-3M0-131743131744 HAZ-37-3M5-131744131745 HAZ-37-4M0-131745131746 HAZ-37-4M5-131746131747 HAZ-37-5M0-131747131748 HAZ-37-5M5-131748131749 HAZ-37-6M0-131749131750 HAZ-37-6M5-131750131751 HAZ-37-7M0-131751131752 HAZ-37-7M5-131752131753 HAZ-37-8M0-131753131754 HAZ-37-8M5-131754131755 HAZ-37-9M0-131755131756 HAZ-37-9M5-131756131738 HAZ-37-10M0-131738

Cable Screenlenghts 300 mm

26 25

34 3336 35

3032

282931

27

18 17

2224

202123

19

16

1214

151311

Con

nect

or I/

O c

ard

Hon

eyw

ell 1

756

Rac

k IO

Mod

ules

810

46

79

35

2 1

Cable type LIYCY36 x 0,34 mm²

37 19

Con

nect

or H

AZ-R

TP...

(SU

B-D

37

pin

mal

e)

20 1

20 x 0,34 mm²Cable Type LIYCY

PEPPERL+FUCHS

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

Cable Screenlenghts 300 mm

14

20

16

18

12

10

8

6

13

19

15

17

11

9

7

5

Con

nect

or I/

O c

ard

Hon

eyw

ell 1

756

Rac

k IO

Mod

ules

4

2

3

1

36-6066E2XXXXXX / 36-XXXX

Date

Dept.:

01.02.01

Up date:

Scale:

PA-VP

29.01.08vB/Dö

S

Replaces:

in ch.

No.

TD

KT SbOff.

- : - of 3

Norm

Sheet

contr.techn.contr.

2

Con

nect

or H

AZ-R

TP...

(SU

B-D

25

pin

mal

e)

2514

131

NC ---21

------------------------

------------------

------

---

------

------

------

---

---

---

------

NCNC

NCNC

---

------

------

------

---

---

---

------

23

2524

22

I/O Terminal block

12

4

5

3

67

910

8

12

1415

13

17

19

20

18

16

11

white

grey/pink

white/greenbrown/greenwhite/yellow

white/pinkpink/brown

white/greygrey/brown

yellow/brown

red/blue

pinkblue

violetblackred

brown

yellowgrey

green

11

16

181920

17

131415

12

8910

67

34

5

12

cable type LIYCY 20x0,34mm²

SUB-D25 (HAZ 25) (Male)Color code

PartNo. Honeywell 1756 RackIO Modules RTPHAZ-RTP cables

198868 HAZ-25-xMx-198868133678 HAZ-25-0M5-122678131720 HAZ-25-1M0-131720131721 HAZ-25-1M5-131721131722 HAZ-25-2M0-131722131723 HAZ-25-2M5-131723131724 HAZ-25-3M0-131724131725 HAZ-25-3M5-131725131726 HAZ-25-4M0-131726131727 HAZ-25-4M5-131727131728 HAZ-25-5M0-131728131729 HAZ-25-5M5-131729131730 HAZ-25-6M0-131730131731 HAZ-25-6M5-131731131732 HAZ-25-7M0-131732131733 HAZ-25-7M5-131733131734 HAZ-25-8M0-131734131735 HAZ-25-8M5-131735131736 HAZ-25-9M0-131736131737 HAZ-25-9M5-131737131719 HAZ-25-10M0-131719

HAZ - 25 - x M x - XXXXXPartNo. (see table)0 or 5 (0 or half meter)

Length in metersM = meters

Type code:

Pinout Honeywell 1756 Rack IO Modules system cable

System cablePinout

Honeywell 1756 Rack IO Modules

Cable duct grey Cable duct blue

X50, X51

Front door

Rear door

A5

A4

A3

A2

A1

X60, X61

Device

PEPPERL+FUCHS TAB298Cabinet assembly

and redundant Power Supply

800

14.03.00 DN

800

+-

-+

+-

-+

+-

Motherboard

plinth 100

2000

Installation pro side :

max. 10 Boards with 16 I / O modules2 x Power Supply Module

MB

Mounting plate

BA

D C

BA

Boards

Front

A , B

Rear

C , D

Power Supply redundant E1-E2F1-F2

Power supply terminals

MB

with motherboards

Cable duct grey

Power feed alarm

power supply

DIN - Rail

F1

and fuse terminals

power supply

F2

Replaces:Up date:

Dept.:

Date

Scale:

PA-VP

xx.xx.xx--:--

S

No.in ch.TD Off.

of1 : 10 x

contr.

Sheet

Ind.Norm

contr.techn.

- x

A

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

Motherboard

-+

B4B4

B5B5

+-

B3B3

-+

+-

B1B1

B2B2

+-

Section A - B

11- 4

1.21. . 4X51X51

Terminals blue

Cable duct grey Cable duct blue

X50, X51

X30 , X40

X50

X30X40

Front door

Rear door

B5B5A5A5

B4B4A4A4

B3B3A3A3

B2B2A2A2

B1B1A1A1

X60, X61

X10 , X20

X20X10X20X20X10

Device

X10

PEPPERL+FUCHS Cabinet assembly

and HART-Multiplexer

800

600

+-

-+

+-

-++

-

-+

-+

+--

++

-

Motherboard

Power feed -

Socket

HART - Multiplexer system

200

2000

Installation pro side :

max. 10 Boards with 16 I / O modules1 x Master9 x Slaves1 x Power supply module

Installation pro side :

A B

DIN-Rail

Terminals blue

Field cableMounting plate

A B

CD

BA

D C

X30X40

X10 X20

X50EE

Section A - B2 3 54 9876 100 1

BA

Boards Boards

Front

A , BA , B

TerminalsTerminals X10 , X20

Rear

C , DC , D

X30 , X40

Multiplexer E FFE

Power supply terminals

Multiplexer

Power supply terminals X50, X51 X60, X61

with motherboards, marshalling

Motherboard

Cable duct grey

and alarm terminals

XXXXXX / 36-XXXX

TAB174-BUp date:

Dept.:

Date

Scale:

TD

PA-VP

xx.xx.xx--:--

S

No.

in ch.

Replaces:

Off.

1 : 10 of 1

contr.

Sheet

Normcontr.techn.

1

10.12.97 vB vB vB

unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

11- 5

1

1

PA-VP

S techn. Norm

PEPPERL+FUCHS 36-9274_1

vB MBDN

Date

Replaces:

Scale:

Sheet

of

contr.contr.Off.in ch.

XXXXXX / 36-9205B

05.03.04

No.

- : -unau

thor

ized

dis

tribu

tion

and

repr

oduc

tion

proh

ibite

dco

pyrig

ht a

ccor

ding

to D

IN34

xx.xx.xx- : -

TD

Dept.:

Up date:Cables for the

HART Multiplexer-System

L1

PN: 39630

PN: 6

7403

14 p

in ID

C c

onne

ctor

26 p

in ID

C c

onne

ctor

PN: 71966

connecting cable K-HM14,

cable HSY-14

Slave

Slave 1Master Slave 2 ........... Slave 14 max. Slave 15

PN: 3

9611

connecting cable K-HM26,

PN: 71965

PN:114025

cable HSY-26

fem

ale

fem

ale

26

1

Motherboard / FI Module

MB

-PF-

XXXX

X

X20

X1

MB

-PF-

XXXX

X

X20

X1

AP-PF-113984

max.15 max. 31

Slave

cable K-HM-26

cable K-HM14

Master/Slave Master/Slave

RS485

Motherboard Interface Module

. . . . . . . .

. . . .Motherboard Interface Module

L1 L2 Ln L16

PN:114026

PN: 102483connecting cable K-HM14,

connecting cable K-HM26,

with Monitor-SoftwarePC Station

(cable length 1m)(cable length variable - max. 8m)

(connetor quantity variable - max.16 connetors + max. 8m)(16 connetors, cable length 0,45m)

KFD0-HMS-16 (#107851) KFD2-HMM-16 (#107905)

PN: 6

7403

14 p

in ID

C c

onne

ctor

fem

ale

PN: 6

7403

14 p

in ID

C c

onne

ctor

fem

ale

PN: 6

7403

14 p

in ID

C c

onne

ctor

fem

ale

PN: 6

7403

14 p

in ID

C c

onne

ctor

fem

ale

26 p

in ID

C c

onne

ctor

PN: 3

9611

fem

ale

http://www.pepperl-fuchs.com

Subject to reasonable modifications due to technical advances · Copyright PEPPERL+FUCHS · Printed in Germany · TMDOC0944B_ENG

One Company, Two Divisions

Product Range

Digital and analogue sensorsin different technologies

Inductive and capacitive sensors Magnetic sensors Ultrasonic sensors Photoelectric sensors

Incremental and absolute rotary encodersCounters and control equipmentIdentification SystemsAS-Interface

Areas of Application

Machine engineeringConveyor or tansportPackaging and bottlingAutomotive industry

Service Area

Worldwide sales, customer service and consultation via competent an reliable Pepperl+Fuchsassociates ensure that you can contact us wherever or whenever you need us. We have subsidiariesworldwide for your convenience.

Process AutomationDivision

Factory AutomationDivision

Product Range

Signal conditionersIntrinsically safe interface modulesRemote Process Interface (RPI)Intrinsically safe field bus solutionsLevel control sensorsProcess measuring and control systemsengineering at the interface levelIntrinsic safety training

Areas of Application

Chemical industryIndustrial and community sewageOil, gas and petrochemical industryPLC and process control systemsEngineering companies for process systems

Worldwide HeadquatersPepperl+Fuchs GmbH · Königsberger Allee 8768307 Mannheim · GermanyTel. +49 621 7 76-0 · Fax +49 621 7 76-10 00e-Mail: [email protected]

USA HeadquatersPepperl+Fuchs Inc. · 1600 Enterprise ParkwayTwinsburg, Ohio 44087 · Cleveland-USATel. (330) 4 25 35 55 · Fax (330) 4 25 93 85e-Mail: [email protected]

Asia Pacific HeadquatersPepperl+Fuchs Pte Ltd. · P+F Building18 Ayer Rajah Crescent · Singapore 139942Tel. (65) 7 79 90 91 · Fax (65) 8 73 16 37e-Mail: [email protected]