cpg.0 & cpg.1 MV Switchgear for Substation Solutions Single and double busbar panel type GIS system Up to 40.5 kV IEC Standards Up to 38 kV IEEE Standards CA-436-EN-1501 www.ormazabal.com Reliable innovation. Personal solutions.

MV Switchgear for Substation Solutions cpg.0 cpg · MV Switchgear for Substation Solutions ... Up to 40.5 kV IEC Standards ... IEEE Std C37.74 IEEE Std C37.20.3 IEEE Std 1247

Embed Size (px)

Citation preview

Page 1: MV Switchgear for Substation Solutions cpg.0 cpg · MV Switchgear for Substation Solutions ... Up to 40.5 kV IEC Standards ... IEEE Std C37.74 IEEE Std C37.20.3 IEEE Std 1247

cpg.0 & cpg.1

MV Switchgear for Substation Solutions

Single and double busbar panel type GIS system Up to 40.5 kV IEC Standards Up to 38 kV IEEE Standards

CA-436-EN-1501 www.ormazabal.com

Reliable innovation. Personal solutions.

Page 2: MV Switchgear for Substation Solutions cpg.0 cpg · MV Switchgear for Substation Solutions ... Up to 40.5 kV IEC Standards ... IEEE Std C37.74 IEEE Std C37.20.3 IEEE Std 1247

cpg.0 & cpg.1

Safety » Internal arc tested (25-31.5 kA 1s) » Gas insulated & screened system » Mechanical / electrical interlocks to prevent unsafe operations

» Switch position and voltage presence indicators

Reliability » Gas insulated & sealed for life » 100% routine tested at the factory » Seismic tested as per IEEE 693-2005

Efficiency » Modular design extensible to both sides without gas handling

» Easy frontal access to install and to test MV cables and fuses

» Optimised dimensions

Sustainability » Continuous reduction in use of greenhouse gases

» End-of-life management » Use of highly recyclable materials » No SF6 gas use during installations

Continuous Innovation » New values up to 40.5 kV » Preventive cable fault diagnosis » Partial discharge (PD) detection for network diagnosis

PrefaceMV/MV and HV/MV substations are one of the most critical nodes in any electrical network. The increasing demand for electricity, and for more power in these substations, requires that MV panels have to guarantee maximum reliability and service continuity for rated current levels.Following the long years of design, development, manufacturing and commissioning experience in gas insulated switchgear (GIS) in secondary distribution, in 2005 Ormazabal introduced into the world markets the cpg system: High duty, flexible and extensible single and double busbar GIS panels up to 36 kV.During the recent years cpg has been extended to higher electrical ratings, e.g. up to 2500 A and up to 40.5 kVcpg system has already been integrated into several utility, RES, industry and big infrastructure applications. Currently more than 5,000 functional units of this system have been in service in more than 25 countries.

Design

Family

cpg.0 / Single busbar

cpg.1 / Single busbar

cpg.1 / Double busbar

IECIEC 62271-1IEC 62271-200IEC 62271-100IEC 62271-102IEC 62271-105IEC 62271-103

ANSI / IEEECAN CSA C22.2 IEEE Std C37.74IEEE Std C37.20.3IEEE Std 1247IEEE Std C37.123IEEE Std C37.20.4IEEE Std C37.04IEEE Std C37.06IEEE Std C37.09IEEE Std C37.20.7

StandardsGas Tank1

1

Busbar compartment

2

2

Driving mechanism and operator interface

3

3

Switching and breaking devices

1a

1a

Pressure relief duct

1b

1b

Cable compartment

4

LV compartment5

4

5

v

v2

v1

f

f2

f1

c

c

cl

ct

s

s2

s1

Circuit breaker

Circuit breaker

Circuit breaker

Fuse protection

Fuse protection

Fuse protection

Busbar coupling

Longitudinal busbar

coupling

Longitudinal busbar

coupling

Transversal busbar

coupling

Disconnector

Disconnector

Disconnector

rb

Busbar rise

Technical dataGeneral

Metal enclosed, cpg.0 single busbar, cpg.1 single and double busbar. Indoor use up to 1000* m altitudeAmbient Tª: Standard -5 °C to +40 °C* Loss of service continuity: LSC 2Partition class: PM

(*) Other conditions under consultation

IEC Standards

Rated valuescpg.0: Up to 24 kV / 2500 A / 25 kA

Up to 40.5 kV / 1250 A / 25 kAcpg.1: Up to 24 kV / 2000 A / 25 - 31.5 kA

Up to 36 kV / 2000 A / 25 - 31.5 kA

Internal arc classification cpg.0: IAC AFL(R) 25 kA 1 s (R optional)cpg.1: AFL(R) 25 kA 1 s (R optional)

AFL 31.5 kA 1 s

Functionscpg.0: v, f, s, rb, ccpg.1: v1, f1, s1, c / v2,f2, s2, cl, ct

ANSI / IEEE Standards

Rated valuescpg.0: Up to 27 kV / 2250 A / 25 kA Up to 38 kV / 2150 A / 25 kAcpg.1: Up to 27-38 kV / 2000 A /

25 - 31.5 kA

Internal arc qualified (IEEE C37.20.7 ID-S)cpg.0: AFL(R) 25 kA 1 s (R opcional)cpg.1: AFL(R) 25 kA 1 s (R opcional)

AFL 31.5 kA 1 scpg.0 Functions: v, f, s, rb, ccpg.1 Functions: v1, f1, s1, c / v2,f2, s2,

cl, ct