MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS . Wagner 1 , M. Thumm 2 , G. Gantenbein 2 , J. Flamm 2 , J. Neilson 3 , R. Verno 1 MPI für Plasmaphysik, Association EURATOM-IPP , D-85748 Garching, Germany 2 Forschungszentrum Karlsruhe, Association EURATOM-FZK, IHM, D-76021 Karlsruhe, Germany 3 Calabazas Creek Research, 690 Port Drive, San Mateo, CA 94404-1010, USA 4 University of Wisconsin, Madison, Wisconsin, 53706-1691, USA US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan Outline: - Introduction - Broadband beam excitation - Cavity design - Measurements

MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

Embed Size (px)

Citation preview

Page 1: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

MULTI-MODE GENERATOR FOR THE COLD TEST OFBROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS

D. Wagner1, M. Thumm2, G. Gantenbein2, J. Flamm2, J. Neilson3, R. Vernon4

1MPI für Plasmaphysik, Association EURATOM-IPP , D-85748 Garching, Germany2Forschungszentrum Karlsruhe, Association EURATOM-FZK, IHM, D-76021 Karlsruhe, Germany

3Calabazas Creek Research, 690 Port Drive, San Mateo, CA 94404-1010, USA4University of Wisconsin, Madison, Wisconsin, 53706-1691, USA

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

Outline: - Introduction - Broadband beam excitation

- Cavity design- Measurements

Page 2: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

INTRODUCTION (1)

• Testing of quasi-optical mode converters requires the excitation of high-order volume modes at low power levels.

• Mode converters for advanced multi-frequency gyrotrons need to be efficient for different modes over a wide frequency range

• Mode generator required for cold tests to excite several modes with high mode purity in this frequency range

• In our case main modes of interest are:

TE22,6 @ 110.0 GHz

TE24,7 @ 124.7 GHz

Page 3: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

INTRODUCTION (2)

Principle:(Alexandrov et al., Int. J. Infrared and Millimeter Waves, 13 (1992), pp.1369)

caustic

waveguide

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

Page 4: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

INTRODUCTION (3)

-1.0

-0.5

0

0.5

1.0

-1.0 -0.5 0 0.5 1.0

rc

B

k0

kz

kc

– Field distribution of high-order modes can be decomposed into a spectrum of plane waves– All rays ( ) are tangential to the caustic with radius:

– The reflection angles of the rays at the waveguide wall are given by:

*HE

Smn

c x

Rmr

R

z

mnx

m)cos(

fR

cx

k

k mncB

2)sin( 0

0

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

Page 5: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

BROADBAND BEAM EXCITATION (1)

• Gaussian beam excitation using a smooth Gauss horn (output mode mixture app. 86% TE11 + 1% TE11(180°) + 12.6% TM11(180°) + 0.4% TM12 (180°) )

• Linear horn (2 phasing sections)

-2

-1

0

1

2

0 5 10 15

length /

radi

us /

• calculated bandwidth 7%

• center frequency: 122.5 GHz

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

Page 6: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

BROADBAND BEAM EXCITATION (2)

• Ex.: horn pattern at center frequency (122.5 GHz, at z = 59 mm)

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

calculation measurement

Page 7: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

BROADBAND BEAM EXCITATION (3)

• Lens horn contains 2 cylindrical teflon lenses

• Designed to generate astigmatic beam at f = 122.5 GHz with w01 = 10 mm, w02 = 33 mm at d2 = 353 mm

• Measured lens horn beam at the position of the quasi-parabolic mirror:

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

Page 8: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

CAVITY DESIGN (1)

• Cavity profile optimized for - high output mode purity - high Q

mode f (GHz) QD (%) TE22,6 110.00 1658 99.91 TE24,7 124.25 2095 99.77

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

-20

-10

0

10

20

0 25 50 75 100length (mm)

rad

ius

(mm

)

coaxial mode generator cavity

19

20

21

0 25 50 75 100length (mm)

rad

ius

(mm

)

outer cavity wall

0

0.2

0.4

0.6

0.8

1.0

0 25 50 75 100

TE22,6

length (mm)

|V| (

no

rma

lize

d)

Modal Amplitude Distribution

(Ri/Ro=0.44)

Page 9: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

CAVITY DESIGN (2)

• Coupling holes over whole circumference reduces counter rotation minimizes re-radiation

• Calculated frequency dependence of the coupling factor:

-30

-25

-20

-15

110 120 130 140

frequency (GHz)

dB

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

Page 10: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

CAVITY DESIGN (3)

• Optimum mode separation by appropriate choice of inner conductor radii

• Calculated eigenvalue spectra (Ro=19.65mm)

TE22,6 resonance TE24,7 resonance

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

40

42

44

46

48

50

0.2 0.3 0.4 0.5 0.6 0.7

29,4

17,8

37,2

5,13

43,1

7,12 14,9

36,228,4

9,11 19,7

32,3 25,5

21,7

21,6

22,5

22,7

22,6

Ri/Ra

eig

en

valu

e

Ra = 19.651 mm

o

47

49

51

53

55

57

0.2 0.3 0.4 0.5 0.6 0.7

19,9

38,3

7,14

34,4 49,1

9,13 16,10

27,6

37,321,8

11,12

30,642,2

24,7

Ri/Ra

eig

en

valu

e

Coaxial Waveguide Eigenvalue

o

Page 11: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

CAVITY DESIGN (4)

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

45.0

45.2

45.4

45.6

45.8

46.0

0.40 0.42 0.44 0.46 0.48 0.50

TE22,6

Ri/Ra

eig

en

valu

eR

a = 19.651 mm

o

Page 12: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

MEASUREMENTS (1)

• Measured frequency response (Ri/Ro=0.44)

• Calculated and measured mode pattern (vertical polarization) @ 110.0 GHz)

TE22,6

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

-80

-70

-60

-50

-40

-30

-20

109.0 109.5 110.0 110.5 111.0 111.5 112.0f / GHz

dB

mode f (GHz) QD (%) TE22,6 110.00 1658 99.91

Page 13: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

51.0

51.2

51.4

51.6

51.8

52.0

0.40 0.42 0.44 0.46 0.48 0.50

TE24,7

Ri/Ra

eig

en

valu

eCoaxial Waveguide Eigenvalue

CAVITY DESIGN (5)

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

o

Page 14: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

-80

-70

-60

-50

-40

-30

-20

124.0 124.5 125.0 125.5f / GHz

dB

MEASUREMENTS (2)

• Measured frequency response (Ri/Ro=0.44)

• Calculated and measured mode pattern (vertical polarization) @ 124.2 GHz

TE24,7

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

mode f (GHz) QD (%) TE24,7 124.25 2095 99.77

Page 15: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

-80

-70

-60

-50

-40

-30

-20

124.0 124.5 125.0 125.5f / GHz

dB

MEASUREMENTS (3)

• Measured frequency response (Ri/Ro=0.435)

• Calculated and measured mode pattern (vertical polarization) @ 124.33 GHz

TE24,7

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

mode f (GHz) QD (%) TE24,7 124.38 2093 99.77

Page 16: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

51.0

51.2

51.4

51.6

51.8

52.0

0.40 0.42 0.44 0.46 0.48 0.50

TE24,7

resonance TE24,7

Ri/Ra

eig

en

valu

eR

a=19.651 mm

CAVITY DESIGN (6)

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

o

Page 17: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

-80

-70

-60

-50

-40

-30

-20

124.5 124.6 124.7 124.8f / GHz

dB

MEASUREMENTS (4)

• Measured frequency response (Ri/Ro=0.42)

• Calculated and measured mode pattern (vertical polarization) @ 124.65 GHz

TE24,7

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

mode f (GHz) QD (%) TE24,7 124.67 2079 99.73

Page 18: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

MODE GENERATOR SETUP

lens horn

quasi-parabolicmirror

cavity

Page 19: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

MEASUREMENTS (5)

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

Page 20: MULTI-MODE GENERATOR FOR THE COLD TEST OF BROADBAND QUASI-OPTICAL GYROTRON MODE CONVERTERS D. Wagner 1, M. Thumm 2, G. Gantenbein 2, J. Flamm 2, J. Neilson

CONCLUSIONS

US-EU-JPN RF Heating Technology Workshop, September 16-18, 2009, Fukuoka, Japan

• Mode generator for TE22,6 @ 110 GHz and TE24,7 @ 124.7 GHz built and tested.

• First results show clear mode patterns with low counter rotation. Frequency matches design values within 20 MHz.