12
MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

  • Upload
    others

  • View
    22

  • Download
    0

Embed Size (px)

Citation preview

Page 1: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

MT-5 Tracer Meter

RENOGY MT-5 Tracer Meter for MPPT Charge Controller

2775 E. Philadelphia St., Ontario CA 91761

1-800-330-8678

Page 2: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

2

Table of Contents

Important Safety Instructions ........................................................................... 3

General Information ............................................................................................ 3

Identification of Display ..................................................................................... 4

Installation ........................................................................................................... 5

Operation ............................................................................................................. 5

Menu Display..................................................................................................... 5

Data Setting....................................................................................................... 6

System Status Icons and Considerations ........................................................ 7

Error Indicator.................................................................................................... 7

Telecommunication Port .................................................................................... 7

Battery Level Flashing ....................................................................................... 7

Battery capacity AH ........................................................................................... 7

Troubleshooting .................................................................................................. 8

Technical Specifications .................................................................................... 8

Parameters ........................................................................................................ 8

Mechanical Parameters ..................................................................................... 8

Temperature Parameters .................................................................................. 8

CAD Dimensions ............................................................................................... 9

Limited Warranty for Accessories ................................................................... 10

Page 3: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

3

Important Safety Instructions Please save these instructions.

This manual contains important safety, installation, and operating instructions for the

charge controller. The following symbols are used throughout the manual to indicate

potentially dangerous conditions or important safety information.

WARNING: Indicates a potentially dangerous condition. Use extreme caution

when performing this task.

CAUTION: Indicates a critical procedure for safe and proper operation of the controller NOTE: Indicates a procedure or function that is important to the safe and proper

operation of the controller.

General Safety Information

Read all instructions, cautions, and notes in the manual before starting the installation.

There are no serviceable parts inside the MT-5. Do not disassemble or attempt to

repair the meter electronics

Do not allow water to enter the MT-5.

General Information The Renogy MT-5 Tracer meter is the remote digital display used for the 20Amp or 40Amp MPPT Charge Controllers. It is a self-diagnostics meter ideal for monitoring and displaying the current solar system status information and any error indications the system might be experiencing. The information is displayed on a backlit LCD display and is easily navigated using the large buttons on the meter. The MT-5 Tracer meter could also be flush mounted on a wall or flat surface using the mounting frame provided. The MT-5 Tracer is supplied with a 6.5 foot long cable and is connected using the RJ45 port. Key Features

Displays system status and parameters with digital and graphical icons

Battery type function and Battery Amp Hour (Ah) setting function

Temperature compensation coefficient adjustable

Control of the load terminal Included Components

Wall Mounting Frame

6.5 ft. cable Components NOT included

Screws ø 4mm (0.16in)

Page 4: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

4

Identification of Display

1. Load Icon

2. Battery Icon(s)—icon is present if the battery is connected otherwise it will remain

flashing. It will demonstrate the battery level in which each bar represents 20% of the

battery capacity.

3. Solar Icon

4. Error Indicator—indicates improper connection, tracer error, or short circuiting of

the battery or solar panels.

5. Setting Icon—icon is present when the user is modifying parameters of the Tracer 6. Data Units NOTE: The LCD has two different brightness levels. After any button is pressed, the

display’s backlight will be bright. After about 30 seconds the display will turn off

the backlight.

3 2 1

4

5

6

10

Page 5: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

5

Installation CAUTION: Before installing the MT-5 Tracer, apply power and make sure the meter is working properly. Resolve any issues before installing the meter and the meter cable. The MT-5 can be mounted in two ways: Frame Mount or in a Wall Mount. A plastic mounting frame has been included for the purpose of Frame Mounting. If Wall Mounting then the MT-5 faceplate sits flush with the mounting surface and the body of the meter would be able to rest comfortably in a hole cut-out on the mounting surface. NOTE: The screws are NOT included for installation purposes.

Operation The following keys are used to cycle through the screens or adjust the parameters on

the tracer :( K1) SET, (K2) (), (K3) (), (K4) /ESC

Menu Display The MT-5 Tracer displays several screens. Use the (K2) (), (K3) () keys to cycle

through the menu and access the data. The screens are displayed in the following order:

1. Solar Panel Voltage 2. Battery Voltage and Battery Current 3. Load Voltage and Load Current 4. Battery capacity (Ah) and Battery temperature 5. Battery State of Charge (SOC) (%) and Temperature Compensation 6. Battery Amp-hour (Ah) and Battery Type 7. Load Timer 1 and Load Timer 2 Mode 8. Discharge Accumulation in Amp-hour(Ah) and Watt-hour (Wh)

1 2

3

4

5

6

7

8

Page 6: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

6

Data Setting

By pressing the SET button, the user is able to modify some parameters of the meter. They include: Battery Amp-Hours (Ah) (4), Battery Temperature Compensation (5), Battery Type (6), and Load Timer Mode (7). The user uses the (K2) () and (K3) () to adjust the parameter, and then press (K1) SET again to save the setting.

The icon will be displayed when the user is in the SET function. It will disappear once the user is in the reading menu. NOTE: In the menu display above, you will see the screens with the adjustable

parameters because they will have the icon.

Data Setting

NOTE: The user uses the SET function to access the data setting parameter. A symbol will appear by which the user utilizes the (K2) () and (K3) () to adjust the parameter, and then press (K1) SET again to save the setting.

Battery Amp-hour (Ah) Battery Amp-hour ranges from 10Ah to 900Ah. The default value will be 200Ah. Once the user presses the SET button, they will be able to modify the Amp-hours in increments of 10Ah.

Battery Temperature Compensation The data ranges from 0 to 10mV/Cell/°C. When the function is set to 0, there will be no temperature compensation.

Battery Type Choose from a sealed lead acid battery (SEL), a gel battery (GEL), or a flooded battery (FLD).

Load Timer 1 and 2 Mode This screen corresponds with the MPPT charge controller’s Timer 1 and Timer 2 option. The user is able to program the timer from the MT-5 Tracer by choosing the number that corresponds to the desired timer. This information can be found on the manual of the MPPT Charge Controller.

Page 7: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

7

System Status Icons and Considerations Error Indicator

The red LED on the tracer is on or the “ ”symbol is visible in the digital display. Possible reasons for the Error Indicator include:

1. Battery could be disconnected, over voltage, or open circuit. Check connections. Disconnect and reconnect.

2. The system is experiencing overcharging current. Check connections, disconnect and reconnect

3. Solar PV is short circuited. Check connections, disconnect and reconnect.

Telecommunication Port

When the meter running on individual power or the communication is cut off, the MT-5

will display graphical symbols abnormally. Press any key to stop the display and resume

normal activity. IF problem persists, disconnect the port and connect it again. Normal

behavior is when the meter updates every 20 seconds.

NOTE: Errors could occur in the telecommunication port if the connection is not properly secured. Also, too long of a cable may cause some inconsistencies.

Battery Level Flashing

Each strip equals to 20% of battery capacity. The bar that is flashing indicates that the

battery is within the next increment of 20% of the battery capacity. For example: when

the first bar is flashing, the battery is at 1-19% of capacity. Similarly, when the second

bar of the battery is flashing, then the capacity is at 21-39%.

NOTE: The meter measures battery capacity by the voltage it is experiencing. When batteries are charging, they will not necessarily match the accurate battery capacity.

Battery capacity AH

AH is the accumulation of charging, each one minute will count. The data is not accurate

while the charge current is too small. The min. is 1AH, means 1 amps charging for 1

hour, Ah comes to show.

Page 8: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

8

Troubleshooting MT-5 has no display

Verify that the MPPT charge controller is powered on and that it is connected to the MT-5 since the charge controller powers on the Tracer.

LCD display is dim

Check the system battery voltage. The MT-5 needs a minimum of 8 V to operate.

Verify that the temperature is within range of the LCD operating parameters.

MT-5 turns on, but shows no data

MT-5 is potentially damaged or the cable is damaged. Replace the cable by contacting the manufacturer.

MT-5 display does not match product manual

Our products undergo manual revisions from time to time. Please check our website at Renogy-store.com > downloads for latest documentation.

Buttons do not work

Disconnect the MT-5 and clean the faceplate to remove any potential buildup of residue

Reconnect MT-5

Technical Specifications

Parameters

Rated Voltage 12V

Minimum Voltage Suggested 8V

Strong backlight on < 23mA

Low Backlight on < 20mA

Backlight and LED indicator off < 17mA

Mechanical Parameters

Communication Cable RJ45 (8 pin)

Cable Length 6.5 ft.

Faceplate Dimensions 95 x 95mm (3.74 x 3.74in)

Wall Frame Dimensions 110 x 110mm (4.33 x 4.33in)

Temperature Parameters

Operation Temperature -40°F to 140°F

LCD Operation Temperature -14°F to 104°F

Humidity 0-100%

Page 9: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

9

CAD Dimensions

NOTE: Dimensions are in millimeters (inches)

Updated: July 10, 2015

Page 10: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

10

Thank you for your interest in the products and services of RNG Group Inc. By acquiring the products of RNG Group Inc., you have purchased quality. As a sign of confidence in our quality, we are pleased to grant you with the following warranties for our photovoltaic products. 1. Limited Warranty

The products manufactured by RNG Group Inc. (the “Warrantor”) are warranted to be free from defects in workmanship and materials under normal use and service. The warranty is in effect from the date of purchase by the user (the “Purchaser”). This limited warranty covers substantial defects in material or workmanship and performance.

If any RNG Group Inc. product(s) fail to follow this Limited Warranty and any and all power loss is determined by the Warrantor’s technical support team then the Warrantor will either repair or replace the defective product(s) with a new or refurbished product(s). All replacements will be compatible with the original product(s) with an equal or even greater power rating (in some cases). If for any reason RNG Group Inc. is unable to repair or replace the defective product(s) then a refund can occur. *Please note that all outsourced product(s) will not be covered by RNG Group Inc.’s limited material and workmanship warranty. Instead, outsourced products will be covered under the original manufacturer’s warranty, if applicable. Including but not limited to Samlex America, Enphase Energy, MidNite Solar Inc., VMAX USA, UPG (Universal Power Group), etc. Material and Workmanship Warranty period for the following products after August 1st, 2015:

INVT-500-12V; INVT-1000-12V; INVT-1500-12V; INVT-2000-12V 3 year material and

workmanship warranty

AK-10FT-10; AK-10FT-12; AK-20FT-10; AK-20FT-12; AK-30FT-10; AK-30FT-12; AK-40FT-10; AK-40FT-12; AK-9IN-12; BATTERYCB-12IN-4; BATTERYCB-14IN-4; BATTERYCB-16IN-4; EXTCB-1.5FT-12; EXTCB-5FT-10; EXTCB-5FT-12; EXTCB-10FT-10; EXTCB-10FT-12; EXTCB-15FT-10; EXTCB-15FT-12; EXTCB-20FT-10; EXTCB-20FT-12; INVTCB-5FT-4; TRAYCB-8FT-8; TRAYCB-8FT-10; TRAYCB-8FT-12; TRAYCB-16FT-8; TRAYCB-16FT-10; TRAYCB-16FT-12; CNCT-FUSE10; CNCT-FUSE15; CNCT-FUSE20; CNCT-FUSE30; CNCT-MC4; CNCT-MC4Y; TRCRMTR-MT-5; TRCRMTR-MT-150; TRCRMTR-MT-50; TRCRMTR-MT-5; TRCRMTR-MT-1; CTRL-MPPT20; CTRL-MPPT40; CTRL-PWM10DB; CTRL-PWM10; CTRL-PWM20DB; CTRL-PWM30; CTRL-PWM30-LCD; CTRL-PWM5; CTRL-PWM10-LCD-VS; CTRL-PWM20-LCD-VS; CTRL-PWM30-LCD-VS; CTRL-ADV30-LCD; CTRL-WND30; MTS-ZB; MTS-SP100; MTS-TM100; MTS-EC35; MTS-EC40; MTS-EC50; MTS-LF; MTS-MC35; MTS-MC40; MTS-MC50; MTS-RS; MTS-RL5FT; MTS-QMSC; MTS-BDRL10FT; TRCRMTR-MT-150; TOOL-MC4; CTRL-VS-TS; CMP-SF25000; LED-MR16; LED-BULB; LED-BULBX4; LED-STRIP; CMP-B-EGO14.1; CMP-EGO10000; CMP-EGOS2800; CMP-EFL14; CMP-EBOT-S; CMP-EBOX-2.1; CMP-EGOMN2600

1 year material and

workmanship warranty

Limited Warranty for Accessories

www.Renogy.com

Page 11: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

11

2. General Conditions for Warranty Claims For Workmanship and Material Warranty: If the Purchaser experiences any defects in materials and workmanship under normal application, such as defects and/or failures due to manufacturing or due to materials, it is their responsibility to contact the Warrantor’s technical support team. The technicians will offer steps and procedures to test the product(s), repair the product(s) or require the Purchaser to ship the product(s) to the technical support team if needed. Based on the outcome, the warranty service will then be in effect.

This warranty extends only to the original Purchaser. If gifted or resold the customer must go through the original Purchaser in order to claim warranty. Original order information is needed to claim warranty. If original order was shipped within the US, the Purchaser will be responsible for additional shipping costs out of the US. The Customer’s sole and exclusive remedy and the entire liability of the Warrantor, its suppliers and affiliates for breach of the warranty is, either to replace the product(s) or component parts of the product(s) and in some cases refund the product(s) cost. This warranty does not cover labor. Products that have been serviced or replaced under their warranty period do not receive extended warranties. Instead, the serviced/replaced product(s) will abide to the original warranty period issued when first purchased. No employee, agent, dealer or any other person is authorized to give any warranties on behalf of the Warrantor, not expressly set forth in this limited warranty.

3. Exclusions and Limitations The warranty does not cover failures result from incorrect handling, product modifications, installation, conversion or additions, supplements, operation, natural elements (weather), excessive or deficient energy supply, chemicals, the effect of solid bodies or deliberate damage. If the Warrantor determines that the problem with the product(s) is not due to a manufacturing defect in the Warrantor’s workmanship or materials, or otherwise does not qualify for warranty repair, then the Purchaser will be responsible for all costs incurred by the Warrantor necessary to repair, replace and transport the product(s).

The warranty shall be asserted with the Warrantor in writing enclosing a copy of the invoice and a description of the defect/loss of performance within the warranty period. The Warrantor shall accept no returns of product(s) without the previous written request for this. Within five (5) business days of the date of notification, the Warrantor will provide the Purchaser with an RMA number and the location to which the Purchaser must return the defective module(s). Any product(s) returned for valid warranty service shall be shipped at the expense and risk of the Warrantor. The Purchaser must return the product(s) (or, if authorized by the Warrantor, the defective component parts), within fifteen (15) days after issuance of the RMA number. The Warrantor will be under no obligation to accept any returned product(s) that does not have a valid RMA number. All parts that the Warrantor replaces shall become the Warrantor’s property on the date the Warrantor ships the repaired product(s) or part back to the Purchaser. The Warrantor will use all reasonable efforts within thirty (30) days of receipt of the defective product(s) to repair or replace such product(s). If a warranty claim is invalid for any reason, the Purchaser will be charged at the Warrantor’s then-current rates for services performed and will be charged for all necessary repairs and expenses incurred by the Warrantor. If the Warrantor determines that a warranty claim is valid, it will ship the repaired or replaced product(s) to the Purchaser at the Warrantor’s cost.

RNG GROUP INC. MAKES NO OTHER WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY OR CONDITION ARISING OUT OF A COURSE OF DEALING, CUSTOMER OR USAGE OF TRADE.

Page 12: MT-5 Tracer Meter - Renogy · MT-5 Tracer Meter RENOGY MT-5 Tracer Meter for MPPT Charge Controller 2775 E. Philadelphia St., Ontario CA 91761 1-800-330-8678

12

LIMITATION OF LIABILITY

UNDER NO CIRCUMSTANCES WILL RNG GROUP INC. OR ITS AFFILIATES OR SUPPLIERS BE LIABLE OR RESPONSIBLE FOR ANY LOSS OF USE, INTERRUPTION OF BUSINESS, LOST PROFITS, LOST DATA, OR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT, TORT (INCLUDING NEGLIGENCE), STRICT LIABILITY OR OTHERWISE, EVEN IF RENOGY OR ITS AFFILIATE OR SUPPLIER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

Some states do not allow the exclusion or limitation of incidental or consequential damages, so these limitations may not apply to you. Neither RNG Group Inc. nor its affiliates or suppliers will be held liable or responsible for any damage or loss to any items or products connected to, powered by or otherwise attached to the Product. The total cumulative liability to the Purchaser, from all causes of action and all theories of liability, will be limited to and will not exceed the purchase price of the Product paid by the Purchaser. This warranty gives you specific legal rights and you may also have other legal rights that vary from state to state.

RNG Group Inc.

2775 E. Philadelphia St. Ontario, CA 91761

Phone: 800-300-8678 Fax: 888-543-1164

Email: General Inquiries: [email protected] Sales Inquiries: [email protected]

Technical Support Inquiries: [email protected] Customer Service Inquiries:[email protected]