SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice. 1
MPI MicroPositioner
MP25 MicroPositioner: The Small One
MPI offers a huge variety of backlash-free MicroPositioners to address every operational and measure-ment condition, varying from small footprint to micrometer driven high-resolution positioners for RF and mmW applications.
Unified Z-direction, ergonomic operation, and a strong magnetic base enable fine probe placement for high contact quality, producing unsurpassed measurement results. MPI MicroPositioners are designed with universal interface compatible to all probe arms for ease of application specific adaptations.
Design varieties allow operators to choose MicroPositioners which fit their operational familiarity, thus providing immediate proficiency.
The MPI self-developed MicroPositioners are designed without compromise. The full carbon-steel structure enables stable contact over long periods of time and superior positioning accuracy.
Feature resolution: < 4 µmTravel range (X/Y/Z): 10 / 10 / 10 mmScrew resolution (X/Y/Z): 500 / 500 / 500 µmMounting: MagneticBase stage size: 25 mmFootprint: 55 mm x 40 mmVersions: Right or leftApplication: IV/CV coaxial and ultra-low current triaxial
measurements
Dimensions - DC arm and tip
unit: mm
QMS-W-AS-02
SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice. 2
MP40 MicroPositioner: The Universal One
Feature resolution: < 3 µmTravel range (X/Y/Z): 13 / 13 / 13 mmScrew resolution (X/Y/Z): 300 / 300 / 300 µmMounting: MagneticBase stage size: 40 mmFootprint: 65 x 40 mmVersions: UnidirectionalApplication: Accurate IV/CV coaxial, ultra-low current
triaxial and RF measurements
Dimensions - DC arm and tip
Dimensions - RF arm (E/W) and TITAN™ probe
224.7
4058
55.7
86.9
4057
Dimensions - RF arm (N/S) and TITAN™ probe
111.5 5090
74.3 92
.3
19.1
74.392
.3
50 79103.4106.4
134.6
19.1
unit: mm
SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice. 3
MP50 MicroPositioner: The Kelvin One
Feature resolution: < 2 µmTravel range (X/Y/Z): 13 / 13 / 13 mmScrew resolution (X/Y/Z): 250 / 250 / 250 µm or 500 / 500 / 500 µmMounting: MagneticBase stage size: 50 mmFootprint: 86 x 60 mmVersions: Right and leftApplication: Extreme accurate IV/CV coaxial, ultra-low current
triaxial measurements, internal node probing
Dimensions - DC arm and tip
Dimensions - Flex arm and tip
115
687686
Y2=2
0
Y3=3
3
15
Y1=9
506073
70 4578
92
506073
7078
92
45
205*
115
687686
Y2=2
0
Y3=3
3
15
Y1=9
506073
70 4578
92
687686
Y1=1
5
18mm Travel range
Each step is 20 Total 180 DOF
Each step is 20 Total 200 DOF
unit: mm
*Can vary depends on adjusted positions
SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice. 4
MP60 MicroPositioner: The RF One
Feature resolution: < 2 µmTravel range (X/Y/Z): 13 / 13 / 13 mmScrew resolution (X/Y/Z): 250 / 250 / 300 µm or 500 / 500 / 300 µmMounting: MagneticBase stage size: 60 mmFootprint: 89 x 60 mmVersions: Right and leftApplication: Accurate and stable RF measurements
Dimensions - E/W arms and TITAN™ probe
88.810
5.8
7082106.4109.4
137.6
19.1
252.6
6082
55.7
86.9
6082
Dimensions - N/S arms
114.5 70
19.1
115
88.8 10
5.8
unit: mm
SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice. 5
MP60-MR MicroPositioner: The Micrometer One
Feature resolution: < 2 µmTravel range (X/Y/Z): 13 / 13 / 13 mmScrew resolution (X/Y/Z): 500 / 500 / 300 µmMounting: MagneticBase stage size: 60 mmFootprint: 89 x 60 mmVersions: Right and leftApplication: Accurate and stable RF measurements
88.810
5.8
70 82106.4109.4
137.6
19.1
Dimensions - E/W arms and TITAN™ probe
6095
.6
266.1
unit: mm
MP80 MicroPositioner: The mmW One
Feature resolution: < 2 µmTravel range (X/Y/Z): 25 / 25 / 15 mmScrew resolution (X/Y/Z): 500 / 500 / 500 µmMounting: Bolt-downBase stage size: 80 mmFootprint: 100 x 80 mmVersions: Right and leftApplication: Accurate and stable RF measurements,
broadband and mmW measurements
127
.5
80
102
196
131
146
.68
90
100
次序 更改區域 原來 更改 日期 負責人-
615.81
A
C
A
C
旺矽科技股份有限公司MPI CORPORATION
版
次
圖號 圖名重量材 質
羅 均 宇姓 名
比 例日 期
繪 圖設 計審 校核 准加工一般公差
鈑金一般公差 孔與孔中心距公差 鑽孔與沉頭孔公差 角度公差
等級
127
.5
80
102
196
131
146
.68
90
100
次序 更改區域 原來 更改 日期 負責人-
615.81
A
C
A
C
旺矽科技股份有限公司MPI CORPORATION
版
次
圖號 圖名重量材 質
羅 均 宇姓 名
比 例日 期
繪 圖設 計審 校核 准加工一般公差
鈑金一般公差 孔與孔中心距公差 鑽孔與沉頭孔公差 角度公差
等級unit: mm
SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice. 6
PMP80 MicroPositioner: The Programmable One
Feature resolution: < 2 µmTravel range (X/Y/Z): 25 / 25 / 10 mmScrew resolution (X/Y/Z): 1000 / 1000 / 1000 µmMounting: Bolt-downBase stage size: 80 mmFootprint: 216 x 193 mmVersions: Right and leftApplication: Accurate and stable RF measurements,
broadband and mmW measurements
MP80-DX MicroPositioner: The multi-line TRL
Feature resolution: < 2 µmTravel range (X/Y/Z): 25 / 25 / 15 mmScrew resolution (X/Y/Z): 500 / 500 / 500 µmMounting: Bolt-downBase stage size: 80 mmFootprint: 100 x 80 mmVersions: Right and leftApplication: Accurate and stable RF, broadband and mmW
measurements. Ideal for multi-line TRL calibration
80
175
.5
102
196
111
146
.68
90
100
次序 更改區域 原來 更改 日期 負責人-
633.44
A
C
A
C
旺矽科技股份有限公司MPI CORPORATION
版
次
圖號 圖名重量材 質
羅 均 宇姓 名
比 例日 期
繪 圖設 計審 校核 准加工一般公差
鈑金一般公差 孔與孔中心距公差 鑽孔與沉頭孔公差 角度公差
等級
80
175
.5
102
196
111
146
.68
90
100
次序 更改區域 原來 更改 日期 負責人-
633.44
A
C
A
C
旺矽科技股份有限公司MPI CORPORATION
版
次
圖號 圖名重量材 質
羅 均 宇姓 名
比 例日 期
繪 圖設 計審 校核 准加工一般公差
鈑金一般公差 孔與孔中心距公差 鑽孔與沉頭孔公差 角度公差
等級 unit: mm
254.
5
121235.5
241.
2
216
unit: mm
SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice. 7
Application / Positioners
Stage (mm) TPI IV / CV
CoaxLow-level,
IV, TriaxIV/CV/PIV
Kelvin RF Broadband mmW
High Power HC / HV
MP25 25 50 - - - - / MP40 40 85 - / MP50MP50-HR 50 50
100 - - - /
MP60MP60-HR 60 50
100 - - /
MP60-MR 60 50 - - /
MP80MP80-DX 80 50 - - - -
PMP80 - - - - - - -
* = recommended = available
MicroPositioner – Application Matrix
MicroPositioner – Probe System Platform Matrix
Platform / Positioners TS50 TS150 TS150-THZ
TS200-THZTS200TS300
TS200-SETS300-SE
TS2000D/DP/SE
TS3000TS3000-SE
MP25
MP40MP50MP50-HRMP60MP60-HRMP60-MR
MP80MP80-DX -
PMP80 - - - - -
* = recommended = available
Probe Arms – MicroPositioner Matrix
Probe Arms/ MicroPositioners Coax Coax
10kV Triax Triax3kV Kelvin RF HC Dedicated
mmWMP25 - - - -MP40
MP50MP50-HR - -
MP60MP60-HR -
MP60-MR -MP80 / PMP80MP80-DX - - - - - -
* = recommended = available = DC biasing
8
MPI Global Presence
Direct contact: Asia region: [email protected]
EMEA region: [email protected] region: [email protected]
MPI global presence: for your local support, please find the right contact here:www.mpi-corporation.com/ast/support/local-support-worldwide
*See MPI Corporation‘s Terms and Conditions of Sale for more details.
SELECTION GUIDE - MicroPositioner, QMS-C-AS-005-02, 10-2018 © MPI Corporation 2018 - Data subject to change without further notice.
MPI offers a complete portfolio of accessories including coaxial, triaxial, RF probe arms, high-tempera-ture Kelvin and high-current probes up to 400 A.
MPI Accessories
Kelvin ArmsThe MPI Kelvin probe holder has a unique vertical self-leveling probe tip which is isolated as close as possible to the DUT up to 300 °C. They are the new benchmark for accurate ultra-low noise, impedance or pulsed-IV mea-surements. Making a novice user able to perform fast and accurate measure-ments, Kelvin probes provide easy reconfiguration for 4TP-connection or/and splitting the ground for pulsed-IV tests. Clear labeling for Force/Sense or High/Low potentials is available.
RF ArmsRF probe arms enable easy and very convenient probe planarization having a large cap on top of the high-end Mitutoyo micrometer and dedicated labe-ling for the proper direction. The fast and tool-less vertical height adjustments with built-in mm-scale is a small example of great usability by working with different RF probe technologies. Every arm comes in standard configuration with two cable strength-relieves, which guide the cables even in case of dual RF probes safety and tender without crushing the cables.
Flex ArmsMPI Flexible probe arms are designed explicitly to address the specific requi-rements of Product Engineering, Failure Analysis and Design Validation appli-cations. Simultaneously probing with probe cards, even at negative tempera-ture are supported by free adjustable angles and lengths of the arm. In parallel the design provides maximum on stability in order to perform measurements on small features. Non-50 Ohm cable-end option offers easy connection with oscilloscopes as example!
AccessoriesExtensive selection and dedicated design of vibration isolation platforms, tables with integrated racks for computer, keyboard tray, a dual monitor stand, EMI-shielded DarkBoxes, probe cards and PCB test holders, vacuum pumps and air compressors are a few examples for the variety of accessories comple-ting the common MPI Test Solution Systems.