  • WARNING DEFINITIONS The warnings described in this manual have the following meanings:

    DANGER An imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING A potentially hazardous situation which, if not avoided, could result in death or serious injury.

    CAUTION

    A potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage to the instrument.

    NOTE Information or cautions to use the device correctly.

    © 2015 A&D Company Ltd. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated into any language in any form by any means without the written permission of A&D Company Ltd. The contents of this manual and the specifications of the instrument covered by this manual are subject to change for improvement without notice.

  • 1

    CONTENTS

    CONTENTS .......................................................................................................................................... 1 1. FOR SAFE USE ........................................................................................................................... 3 1-1 Precaution on the pipette use .................................................................................. 3 1-2 Precautions on handling the battery ........................................................................ 3

    2. INTRODUCTION .......................................................................................................................... 4 3. FEATURE ..................................................................................................................................... 4 4. COMPLIANCE ............................................................................................................................. 5 5. MPA FUNCTION .......................................................................................................................... 7 6. PACKING CONTENTS AND NAME OF ITEMS .......................................................................... 8 7. PREPARATION BEFORE USE ................................................................................................. 10 7-1 Installing the battery ............................................................................................... 10 7-2 Recharging the battery ........................................................................................... 11 7-3 Exchange Selectable power plug .......................................................................... 12 7-4 Before operating the pipette .................................................................................. 13 7-5 Parts names and materials .................................................................................... 14 7-6 Precautions before dispensing .............................................................................. 15

    8. NAME AND FUNCTIONS OF DISPLAY AND KEYS ................................................................ 16 8-1 Display and functions ............................................................................................. 16 8-2 Key switches and functions ................................................................................... 17

    9. FUNCTION AND HOW TO USE ................................................................................................ 18 9-1 Standard mode (AUTO) ......................................................................................... 18 9-2 Multiple dispensing mode (MD) ............................................................................. 19 9-3 Mixing mode(MIX) ............................................................................................. 22 9-4 System setting mode(SYS) ............................................................................... 24 9-5 Program setting mode ........................................................................................... 26 9-6 Reverse operation (Dispensing liquid that tends to remain in the tip) ................... 26 9-7 Blowout function .................................................................................................... 28 9-8 Total discharge function ......................................................................................... 29 9-9 “Pre-dispensing function” for multiple dispensing .................................................. 29 9-10 Advanced dispensing jobs ................................................................................... 29

    10. PIPETTING FOR ACCURATE DISPENSING ............................................................................ 30 11. CALIBRATING THE PIPETTE USING AN ELECTRONIC BALANCE ........................................................ 31 11-1 Volume calibration function (μL calibration function) ............................................ 31 11-2 Resetting the volume calibration .......................................................................... 32 11-3 Dispensing in a unit of weight (in mg unit) .......................................................... 33 11-4 Weight calibration function (mg calibration function) ........................................... 34

    12. ADJUSTING TIP EJECTOR HEIGHT ................................................................................ 36 13. STORAGE AND MAINTENANCE ............................................................................................. 36

  • 2

    13-1 Replacing the lower part ...................................................................................... 36 13-2 Cleaning the tip holder ......................................................................................... 37 13-3 After maintenance performance check ................................................................ 37 13-4 Autoclave ............................................................................................................. 37

    14. TROUBLE SHOOTING .............................................................................................................. 38 15. WHEN REQUESTNG REPAIRE ................................................................................................ 40 16. SPECIFICATIONS ..................................................................................................................... 41 17. LIST OF ITEMS SOLD SEPARATELY(DISPOSABLE ITEMS) ...................................... 42 17-1 Stands and hanger ............................................................................................... 42 17-2 Tips, tip boxes and the filter ................................................................................. 43 17-3 Disposable items (User replaceable) ................................................................... 45 17-4 Inspection equipment ........................................................................................... 46

  • 3

    1. FOR SAFE USE

    1-1 Precaution on the pipette use DANGER

    - This instrument is not an explosion proof instrument. Do not use the pipette in an environment where there is a risk of explosion, or use it for explosive chemicals that may cause explosion.

    - When using potentially harmful solutions, such as infectious bacteria or viruses, radioactive substances that have a risk of exposure, or poisons, exercise extreme caution and follow all safety measures.

    CAUTION - Please refer to “7-5 Parts names and materials” and “17-2 Tips, tip boxes and the

    filter” for compatibility when organic solvents or corrosive solutions are to be dispensed.

    - Do not attempt to disassemble or repair the pipette by yourself. Refer to “14. TROUBLE SHOOTING” when it appears that the pipette has a mechanical error.

    1-2 Precautions on handling the battery The MPA series use the high-density lithium-ion battery. To prevent injuries or accidents due to a leaking battery, heat generation, fire or burst, and to ensure safe use, be sure to keep the manual on hand.

    DANGER - Do not dispose of the battery in fire, do not heat it, do not disassemble or modify it. - Do not splash water on the battery, or do not keep the battery in a location at high

    temperature or high humidity. - Do not allow battery contacts to contact metal. When keeping or carrying the battery,

    be sure not to allow the battery to contact metal.

    WARNING - Recharge the batteries with pipette installed. The pipette can be used even when

    the battery is being recharged. - When recharging is unsuccessful even after charging for the specified time (Five

    hours up to fully recharged), stop recharging a battery. - Use only the supplied with the pipette. Do not use other batteries.

  • 4

    CAUTION - Do not use a leaking battery. - Because the battery body may become hot when using the pipette continuously for

    a long time, take care not to get burned when handling it. - Should you get battery fluid from a leaking battery in your eye, immediately flush

    with copious amounts of water and seek immediate medical attention. Should the liquid contact the clothes or skin, rinse immediately with copious amounts of water.

    2. INTRODUCTION Thank you for purchasing the MPA series electronic pipette. To ensure safe use of the product, be sure to read the ma